mibs/MIBS/DS3-MIB

1795 lines
61 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
DS3-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, transmission
FROM SNMPv2-SMI -- [RFC2578 </rfcs/rfc2578.html>]
DisplayString, TimeStamp, TruthValue
FROM SNMPv2-TC -- [RFC2579 </rfcs/rfc2579.html>]
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF -- [RFC2580 </rfcs/rfc2580.html>]
InterfaceIndex
FROM IF-MIB -- [RFC2863 </rfcs/rfc2863.html>]
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount
FROM PerfHist-TC-MIB; -- [RFC3593 </rfcs/rfc3593.html>]
ds3 MODULE-IDENTITY
LAST-UPDATED "200409080000Z" -- September 08, 2004
ORGANIZATION "IETF AToM MIB Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/atommib-charter.html
Mailing Lists:
General Discussion: atommib@research.telcordia.com <mailto:atommib@research.telcordia.com>
To Subscribe: atommib-request@research.telcordia.com <mailto:atommib-request@research.telcordia.com>
Editor: Orly Nicklass
Postal: RAD Data Communications, Ltd.
Ziv Tower, 24 Roul Walenberg
Tel Aviv, Israel, 69719
Tel: +9723 765 9969
E-mail: orly_n@rad.com <mailto:orly_n@rad.com>"
DESCRIPTION
"The is the MIB module that describes
DS3 and E3 interfaces objects.
Copyright (c) The Internet Society (2004). This
version of this MIB module is part of RFC 3896 </rfcs/rfc3896.html>;
see the RFC itself for full legal notices."
REVISION "200409080000Z" -- September 08, 2004
DESCRIPTION
"The RFC 3896 </rfcs/rfc3896.html> version of this MIB module.
The key changes made to this MIB module
since its publication in RFC 2496 </rfcs/rfc2496.html> are as follows:
(1) The dsx3FracIfIndex SYNTAX matches the description range.
(2) Reference was added to Circuit Identifier object.
(3) Usage of ifStackTable section was updated.
(4) Align the DESCRIPTION clauses of few statistic objects with
thenear end definition, the far end definition and with
RFC 3593 </rfcs/rfc3593.html>.
(5) Add new value, dsx3M13, to dsx3LineType."
REVISION "199808012130Z"
DESCRIPTION
"The RFC 2496 </rfcs/rfc2496.html> version of this MIB module.
The key changes made to this MIB module
since its publication in RFC 1407 </rfcs/rfc1407.html> are as follows:
(1) The Fractional Table has been deprecated.
(2) This document uses SMIv2.
(3) Values are given for ifTable and ifXTable.
(4) Example usage of ifStackTable is included.
(5) dsx3IfIndex has been deprecated.
(6) The definition of valid intervals has been clarified
for the case where the agent proxied for other devices.
In particular, the treatment of missing intervals has
been clarified.
(7) An inward loopback has been added.
(8) Additional lineStatus bits have been added for Near End
in Unavailable Signal State, Carrier Equipment Out of
Service.
(9) A read-write line Length object has been added.
(10) Added a lineStatus last change, trap and enabler.
(11) Textual Conventions for statistics objects have
been used.
(12) A new object, dsx3LoopbackStatus, has been introduced to
reflect the loopbacks established on a DS3/E3 interface
and the source to the requests. dsx3LoopbackConfig
continues to be the desired loopback state while
dsx3LoopbackStatus reflects the actual state.
(13) A dual loopback has been added to allow the setting of
an inward loopback and a line loopback at the same time.
(14) An object has been added to indicated whether or not
this is a channelized DS3/E3.
(15) A new object has been added to indicate which DS1 is to
set for remote loopback."
REVISION "199301252028Z"
DESCRIPTION
"Initial version, published as RFC 1407 </rfcs/rfc1407.html>."
::= { transmission 30 }
-- The DS3/E3 Near End Group
-- The DS3/E3 Near End Group consists of four tables:
-- DS3/E3 Configuration
-- DS3/E3 Current
-- DS3/E3 Interval
-- DS3/E3 Total
-- the DS3/E3 Configuration Table
dsx3ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3/E3 Configuration table."
::= { ds3 5 }
dsx3ConfigEntry OBJECT-TYPE
SYNTAX Dsx3ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3/E3 Configuration table."
INDEX { dsx3LineIndex }
::= { dsx3ConfigTable 1 }
Dsx3ConfigEntry ::=
SEQUENCE {
dsx3LineIndex InterfaceIndex,
dsx3IfIndex InterfaceIndex,
dsx3TimeElapsed INTEGER,
dsx3ValidIntervals INTEGER,
dsx3LineType INTEGER,
dsx3LineCoding INTEGER,
dsx3SendCode INTEGER,
dsx3CircuitIdentifier DisplayString,
dsx3LoopbackConfig INTEGER,
dsx3LineStatus INTEGER,
dsx3TransmitClockSource INTEGER,
dsx3InvalidIntervals INTEGER,
dsx3LineLength INTEGER,
dsx3LineStatusLastChange TimeStamp,
dsx3LineStatusChangeTrapEnable INTEGER,
dsx3LoopbackStatus INTEGER,
dsx3Channelization INTEGER,
dsx3Ds1ForRemoteLoop INTEGER
}
dsx3LineIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex allows proper
use of ifStackTable.
Previously, this object was the identifier of a
DS3/E3 Interface on a managed device. If there is
an ifEntry that is directly associated with this
and only this DS3/E3 interface, it should have the
same value as ifIndex. Otherwise, number the
dsx3LineIndices with an unique identifier
following the rules of choosing a number that is
greater than ifNumber and numbering the inside
interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g., network side)
with odd numbers."
::= { dsx3ConfigEntry 1 }
dsx3IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This value for this object is equal to the value
of ifIndex from the Interfaces table of MIB II
(RFC 1213 </rfcs/rfc1213.html>)."
::= { dsx3ConfigEntry 2 }
dsx3TimeElapsed OBJECT-TYPE
SYNTAX INTEGER (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the near end current error-
measurement period. If, for some reason, such as
an adjustment in the system's time-of-day clock,
the current interval exceeds the maximum value,
the agent will return the maximum value."
::= { dsx3ConfigEntry 3 }
dsx3ValidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which data was collected. The value will be 96
unless the interface was brought online within the
last 24 hours, in which case the value will be the
number of complete 15 minute near end intervals
since the interface has been online. In the case
where the agent is a proxy, it is possible that
some intervals are unavailable. In this case,
this interval is the maximum interval number for
which data is available."
::= { dsx3ConfigEntry 4 }
dsx3LineType OBJECT-TYPE
SYNTAX INTEGER {
dsx3other(1),
dsx3M23(2),
dsx3SYNTRAN(3),
dsx3CbitParity(4),
dsx3ClearChannel(5),
e3other(6),
e3Framed(7),
e3Plcp(8),
dsx3M13(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the variety of DS3 C-bit
or E3 application implementing this interface. The
type of interface affects the interpretation of
the usage and error statistics. The rate of DS3
is 44.736 Mbps and E3 is 34.368 Mbps. The
dsx3ClearChannel value means that the C-bits are
not used except for sending/receiving AIS. The
values, in sequence, describe:
TITLE: SPECIFICATION:
dsx3M23 ANSI T1.107-1988
dsx3SYNTRAN ANSI T1.107-1988
dsx3CbitParity ANSI T1.107a-1990
dsx3ClearChannel ANSI T1.102-1987
e3Framed CCITT G.751
e3Plcp ETSI T/NA(91)18
dsx3M13 ANSI T1.107a-1990."
REFERENCE
"American National Standard for telecommunications
- digital hierarchy -
formats specification, ANSI T1.107- 1988.
ANSI T1.107a-1990.
American National Standard for telecommunications
- digital hierarchy -
electrical interfaces, ANSI T1.102- 1987.
CCITT - Digital Multiplex Equipment Operating at
the Third Order Bit Rate of 34 368 Kbit/s and
the Forth Order Bit Rate of 139 264 Kbit/s
and Using Positive Justification, G.751
European Telecommunications Standards Institute
-- ETS '34M' --
Metropolitan Area Network Physical
Convergence Layer Procedure for
34.368 Megabits per Second, T/NA(91)18,
May 1991."
::= { dsx3ConfigEntry 5 }
dsx3LineCoding OBJECT-TYPE
SYNTAX INTEGER {
dsx3Other(1),
dsx3B3ZS(2),
e3HDB3(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the variety of Zero Code
Suppression used on this interface, which in turn
affects a number of its characteristics.
dsx3B3ZS and e3HDB3 refer to the use of specified
patterns of normal bits and bipolar violations
which are used to replace sequences of zero bits
of a specified length."
::= { dsx3ConfigEntry 6 }
dsx3SendCode OBJECT-TYPE
SYNTAX INTEGER {
dsx3SendNoCode(1),
dsx3SendLineCode(2),
dsx3SendPayloadCode(3),
dsx3SendResetCode(4),
dsx3SendDS1LoopCode(5),
dsx3SendTestPattern(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates what type of code is
being sent across the DS3/E3 interface by the
device. (These are optional for E3 interfaces.)
Setting this variable causes the interface to
begin sending the code requested.
The values mean:
dsx3SendNoCode
sending looped or normal data
dsx3SendLineCode
sending a request for a line loopback
dsx3SendPayloadCode
sending a request for a payload loopback
(i.e., all DS1/E1s in a DS3/E3 frame)
dsx3SendResetCode
sending a loopback deactivation request
dsx3SendDS1LoopCode
requesting to loopback a particular DS1/E1
within a DS3/E3 frame. The DS1/E1 is
indicated in dsx3Ds1ForRemoteLoop.
dsx3SendTestPattern
sending a test pattern."
::= { dsx3ConfigEntry 7 }
dsx3CircuitIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable contains the transmission vendor's
circuit identifier, for the purpose of
facilitating troubleshooting."
REFERENCE "ITU-T M.1400"
::= { dsx3ConfigEntry 8 }
dsx3LoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
dsx3NoLoop(1),
dsx3PayloadLoop(2),
dsx3LineLoop(3),
dsx3OtherLoop(4),
dsx3InwardLoop(5),
dsx3DualLoop(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the desired loopback
configuration of the DS3/E3 interface.
The values mean:
dsx3NoLoop
Not in the loopback state. A device that is
not capable of performing a loopback on
the interface shall always return this as
its value.
dsx3PayloadLoop
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.
dsx3LineLoop
The received signal at this interface does not
go through the device (minimum penetration) but
is looped back out.
dsx3OtherLoop
Loopbacks that are not defined here.
dsx3InwardLoop
The sent signal at this interface is looped back
through the device.
dsx3DualLoop
Both dsx1LineLoop and dsx1InwardLoop will be
active simultaneously."
::= { dsx3ConfigEntry 9 }
dsx3LineStatus OBJECT-TYPE
SYNTAX INTEGER (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Line Status of the
interface. It contains loopback state information
and failure state information. The dsx3LineStatus
is a bit map represented as a sum, therefore, it
can represent multiple failures and a loopback
(see dsx3LoopbackConfig object for the type of
loopback) simultaneously. The dsx3NoAlarm must be
set if and only if no other flag is set.
If the dsx3loopbackState bit is set, the loopback
in effect can be determined from the
dsx3loopbackConfig object.
The various bit positions are:
1 dsx3NoAlarm No alarm present
2 dsx3RcvRAIFailure Receiving Yellow/Remote
Alarm Indication
4 dsx3XmitRAIAlarm Transmitting Yellow/Remote
Alarm Indication
8 dsx3RcvAIS Receiving AIS failure state
16 dsx3XmitAIS Transmitting AIS
32 dsx3LOF Receiving LOF failure state
64 dsx3LOS Receiving LOS failure state
128 dsx3LoopbackState Looping the received signal
256 dsx3RcvTestCode Receiving a Test Pattern
512 dsx3OtherFailure any line status not defined
here
1024 dsx3UnavailSigState Near End in Unavailable
Signal State
2048 dsx3NetEquipOOS Carrier Equipment Out of
Service"
::= { dsx3ConfigEntry 10 }
dsx3TransmitClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
loopTiming indicates that the recovered receive
clock is used as the transmit clock.
localTiming indicates that a local clock source is
used or that an external clock is attached to the
box containing the interface.
throughTiming indicates that transmit clock is
derived from the recovered receive clock of
another DS3 interface."
::= { dsx3ConfigEntry 11 }
dsx3InvalidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of intervals in the range from 0 to
dsx3ValidIntervals for which no data is available.
This object will typically be zero except in cases
where the data for some intervals are not
available (e.g., in proxy situations)."
::= { dsx3ConfigEntry 12 }
dsx3LineLength OBJECT-TYPE
SYNTAX INTEGER (0..64000)
UNITS "meters"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out."
::= { dsx3ConfigEntry 13 }
dsx3LineStatusLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of MIB II's sysUpTime object at the
time this DS3/E3 entered its current line status
state. If the current state was entered prior to
the last re-initialization of the proxy-agent,
then this object contains a zero value."
::= { dsx3ConfigEntry 14 }
dsx3LineStatusChangeTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether dsx3LineStatusChange traps
should be generated for this interface."
DEFVAL { disabled }
::= { dsx3ConfigEntry 15 }
dsx3LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the current state of the
loopback on the DS3 interface. It contains
information about loopbacks established by a
manager and remotely from the far end.
The dsx3LoopbackStatus is a bit map represented as
a sum, therefore is can represent multiple
loopbacks simultaneously.
The various bit positions are:
1 dsx3NoLoopback
2 dsx3NearEndPayloadLoopback
4 dsx3NearEndLineLoopback
8 dsx3NearEndOtherLoopback
16 dsx3NearEndInwardLoopback
32 dsx3FarEndPayloadLoopback
64 dsx3FarEndLineLoopback"
::= { dsx3ConfigEntry 16 }
dsx3Channelization OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabledDs1(2),
enabledDs2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether this ds3/e3 is channelized or
unchannelized. The value of enabledDs1 indicates
that this is a DS3 channelized into DS1s. The
value of enabledDs3 indicated that this is a DS3
channelized into DS2s. Setting this object will
cause the creation or deletion of DS2 or DS1
entries in the ifTable. "
::= { dsx3ConfigEntry 17 }
dsx3Ds1ForRemoteLoop OBJECT-TYPE
SYNTAX INTEGER (0..29)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates which DS1/E1 on this DS3/E3 will be
indicated in the remote ds1 loopback request. A
value of 0 means no DS1 will be looped. A value
of 29 means all DS1s/E1s will be looped."
::= { dsx3ConfigEntry 18 }
-- the DS3/E3 Current Table
dsx3CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3/E3 current table contains various
statistics being collected for the current 15
minute interval."
::= { ds3 6 }
dsx3CurrentEntry OBJECT-TYPE
SYNTAX Dsx3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3/E3 Current table."
INDEX { dsx3CurrentIndex }
::= { dsx3CurrentTable 1 }
Dsx3CurrentEntry ::=
SEQUENCE {
dsx3CurrentIndex InterfaceIndex,
dsx3CurrentPESs PerfCurrentCount,
dsx3CurrentPSESs PerfCurrentCount,
dsx3CurrentSEFSs PerfCurrentCount,
dsx3CurrentUASs PerfCurrentCount,
dsx3CurrentLCVs PerfCurrentCount,
dsx3CurrentPCVs PerfCurrentCount,
dsx3CurrentLESs PerfCurrentCount,
dsx3CurrentCCVs PerfCurrentCount,
dsx3CurrentCESs PerfCurrentCount,
dsx3CurrentCSESs PerfCurrentCount
}
dsx3CurrentIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
DS3/E3 interface to which this entry is
applicable. The interface identified by a
particular value of this index is the same
interface as identified by the same value an
dsx3LineIndex object instance."
::= { dsx3CurrentEntry 1 }
dsx3CurrentPESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Errored Seconds."
::= { dsx3CurrentEntry 2 }
dsx3CurrentPSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Severely Errored Seconds."
::= { dsx3CurrentEntry 3 }
dsx3CurrentSEFSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Framing Seconds."
::= { dsx3CurrentEntry 4 }
dsx3CurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds."
::= { dsx3CurrentEntry 5 }
dsx3CurrentLCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
Coding Violations."
::= { dsx3CurrentEntry 6 }
dsx3CurrentPCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Coding Violations."
::= { dsx3CurrentEntry 7 }
dsx3CurrentLESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds."
::= { dsx3CurrentEntry 8 }
dsx3CurrentCCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Coding Violations."
::= { dsx3CurrentEntry 9 }
dsx3CurrentCESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Errored Seconds."
::= { dsx3CurrentEntry 10 }
dsx3CurrentCSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Severely Errored Seconds."
::= { dsx3CurrentEntry 11 }
-- the DS3/E3 Interval Table
dsx3IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3/E3 Interval Table contains various
statistics collected by each DS3/E3 Interface over
the previous 24 hours of operation. The past 24
hours are broken into 96 completed 15 minute
intervals. Each row in this table represents one
such interval (identified by dsx3IntervalNumber)
and for one specific interface (identified by
dsx3IntervalIndex)."
::= { ds3 7 }
dsx3IntervalEntry OBJECT-TYPE
SYNTAX Dsx3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3/E3 Interval table."
INDEX { dsx3IntervalIndex, dsx3IntervalNumber }
::= { dsx3IntervalTable 1 }
Dsx3IntervalEntry ::=
SEQUENCE {
dsx3IntervalIndex InterfaceIndex,
dsx3IntervalNumber INTEGER,
dsx3IntervalPESs PerfIntervalCount,
dsx3IntervalPSESs PerfIntervalCount,
dsx3IntervalSEFSs PerfIntervalCount,
dsx3IntervalUASs PerfIntervalCount,
dsx3IntervalLCVs PerfIntervalCount,
dsx3IntervalPCVs PerfIntervalCount,
dsx3IntervalLESs PerfIntervalCount,
dsx3IntervalCCVs PerfIntervalCount,
dsx3IntervalCESs PerfIntervalCount,
dsx3IntervalCSESs PerfIntervalCount,
dsx3IntervalValidData TruthValue
}
dsx3IntervalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
DS3/E3 interface to which this entry is
applicable. The interface identified by a
particular value of this index is the same
interface as identified by the same value an
dsx3LineIndex object instance."
::= { dsx3IntervalEntry 1 }
dsx3IntervalNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the 15 minutes interval completed 23 hours and 45
minutes prior to interval 1."
::= { dsx3IntervalEntry 2 }
dsx3IntervalPESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Errored Seconds."
::= { dsx3IntervalEntry 3 }
dsx3IntervalPSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Severely Errored Seconds."
::= { dsx3IntervalEntry 4 }
dsx3IntervalSEFSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Framing Seconds."
::= { dsx3IntervalEntry 5 }
dsx3IntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds. This object may decrease if
the occurrence of unavailable seconds occurs across
an interval boundary."
::= { dsx3IntervalEntry 6 }
dsx3IntervalLCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
Coding Violations."
::= { dsx3IntervalEntry 7 }
dsx3IntervalPCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Coding Violations."
::= { dsx3IntervalEntry 8 }
dsx3IntervalLESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds (BPVs or
illegal zero sequences)."
::= { dsx3IntervalEntry 9 }
dsx3IntervalCCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Coding Violations."
::= { dsx3IntervalEntry 10 }
dsx3IntervalCESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Errored Seconds."
::= { dsx3IntervalEntry 11 }
dsx3IntervalCSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Severely Errored Seconds."
::= { dsx3IntervalEntry 12 }
dsx3IntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This variable indicates if the data for this
interval is valid."
::= { dsx3IntervalEntry 13 }
-- the DS3/E3 Total
dsx3TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3/E3 Total Table contains the cumulative
sum of the various statistics for the 24 hour
period preceding the current interval."
::= { ds3 8 }
dsx3TotalEntry OBJECT-TYPE
SYNTAX Dsx3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3/E3 Total table."
INDEX { dsx3TotalIndex }
::= { dsx3TotalTable 1 }
Dsx3TotalEntry ::=
SEQUENCE {
dsx3TotalIndex InterfaceIndex,
dsx3TotalPESs PerfTotalCount,
dsx3TotalPSESs PerfTotalCount,
dsx3TotalSEFSs PerfTotalCount,
dsx3TotalUASs PerfTotalCount,
dsx3TotalLCVs PerfTotalCount,
dsx3TotalPCVs PerfTotalCount,
dsx3TotalLESs PerfTotalCount,
dsx3TotalCCVs PerfTotalCount,
dsx3TotalCESs PerfTotalCount,
dsx3TotalCSESs PerfTotalCount
}
dsx3TotalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
DS3/E3 interface to which this entry is
applicable. The interface identified by a
particular value of this index is the same
interface as identified by the same value an
dsx3LineIndex object instance."
::= { dsx3TotalEntry 1 }
dsx3TotalPESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Errored Seconds, encountered by a DS3 interface in
the previous 24 hour interval. Invalid 15 minute
intervals count as 0."
::= { dsx3TotalEntry 2 }
dsx3TotalPSESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Severely Errored Seconds, encountered by a DS3
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 3 }
dsx3TotalSEFSs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Framing Seconds, encountered by a
DS3/E3 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 4 }
dsx3TotalUASs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds, encountered by a DS3
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 5 }
dsx3TotalLCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
Coding Violations encountered by a DS3/E3
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 6 }
dsx3TotalPCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of P-bit
Coding Violations, encountered by a DS3 interface
in the previous 24 hour interval. Invalid 15
minute intervals count as 0."
::= { dsx3TotalEntry 7 }
dsx3TotalLESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds (BPVs or
illegal zero sequences) encountered by a DS3/E3
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 8 }
dsx3TotalCCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Coding Violations encountered
by a DS3 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 9 }
dsx3TotalCESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Errored Seconds encountered
by a DS3 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as 0."
::= { dsx3TotalEntry 10 }
dsx3TotalCSESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of C-bit Severely Errored Seconds
encountered by a DS3 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx3TotalEntry 11 }
-- The DS3 Far End Group
-- The DS3 Far End Group consists of four tables :
-- DS3 Far End Configuration
-- DS3 Far End Current
-- DS3 Far End Interval
-- DS3 Far End Total
-- The DS3 Far End Configuration Table
dsx3FarEndConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Far End Configuration Table contains
configuration information reported in the C-bits
from the remote end."
::= { ds3 9 }
dsx3FarEndConfigEntry OBJECT-TYPE
SYNTAX Dsx3FarEndConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Far End Configuration table."
INDEX { dsx3FarEndLineIndex }
::= { dsx3FarEndConfigTable 1 }
Dsx3FarEndConfigEntry ::=
SEQUENCE {
dsx3FarEndLineIndex InterfaceIndex,
dsx3FarEndEquipCode DisplayString,
dsx3FarEndLocationIDCode DisplayString,
dsx3FarEndFrameIDCode DisplayString,
dsx3FarEndUnitCode DisplayString,
dsx3FarEndFacilityIDCode DisplayString
}
dsx3FarEndLineIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS3
interface to which this entry is applicable. The
interface identified by a particular value of this
index is the same interface as identified by the
same value an dsx3LineIndex object instance."
::= { dsx3FarEndConfigEntry 1 }
dsx3FarEndEquipCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Far End Equipment Identification code
that describes the specific piece of equipment.
It is sent within the Path Identification
Message."
::= { dsx3FarEndConfigEntry 2 }
dsx3FarEndLocationIDCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Far End Location Identification code
that describes the specific location of the
equipment. It is sent within the Path
Identification Message."
::= { dsx3FarEndConfigEntry 3 }
dsx3FarEndFrameIDCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Far End Frame Identification code
that identifies where the equipment is located
within a building at a given location. It is sent
within the Path Identification Message."
::= { dsx3FarEndConfigEntry 4 }
dsx3FarEndUnitCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Far End code that identifies the
equipment location within a bay. It is sent
within the Path Identification Message."
::= { dsx3FarEndConfigEntry 5 }
dsx3FarEndFacilityIDCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..38))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This code identifies a specific Far End DS3 path.
It is sent within the Path Identification
Message."
::= { dsx3FarEndConfigEntry 6 }
-- The DS3 Far End Current
dsx3FarEndCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Far End Current table contains various
statistics being collected for the current 15
minute interval. The statistics are collected
from the far end block error code within the C-
bits."
::= { ds3 10 }
dsx3FarEndCurrentEntry OBJECT-TYPE
SYNTAX Dsx3FarEndCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Far End Current table."
INDEX { dsx3FarEndCurrentIndex }
::= { dsx3FarEndCurrentTable 1 }
Dsx3FarEndCurrentEntry ::=
SEQUENCE {
dsx3FarEndCurrentIndex InterfaceIndex,
dsx3FarEndTimeElapsed INTEGER,
dsx3FarEndValidIntervals INTEGER,
dsx3FarEndCurrentCESs PerfCurrentCount,
dsx3FarEndCurrentCSESs PerfCurrentCount,
dsx3FarEndCurrentCCVs PerfCurrentCount,
dsx3FarEndCurrentUASs PerfCurrentCount,
dsx3FarEndInvalidIntervals INTEGER
}
dsx3FarEndCurrentIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS3
interface to which this entry is applicable. The
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx3LineIndex."
::= { dsx3FarEndCurrentEntry 1 }
dsx3FarEndTimeElapsed OBJECT-TYPE
SYNTAX INTEGER (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the far end current error-measurement
period. If, for some reason, such as an adjustment
in the system's time-of-day clock, the current
interval exceeds the maximum value, the agent will
return the maximum value."
::= { dsx3FarEndCurrentEntry 2 }
dsx3FarEndValidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous far end intervals for
which data was collected. The value will be 96
unless the interface was brought online within the
last 24 hours, in which case the value will be the
number of complete 15 minute far end intervals
since the interface has been online. In the case
where the agent is a proxy, it is possible that
some intervals are unavailable. In this case,
this interval is the maximum interval number for
which data is available."
::= { dsx3FarEndCurrentEntry 3 }
dsx3FarEndCurrentCESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Errored Seconds."
::= { dsx3FarEndCurrentEntry 4 }
dsx3FarEndCurrentCSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Severely Errored Seconds."
::= { dsx3FarEndCurrentEntry 5 }
dsx3FarEndCurrentCCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Coding Violations reported via the far end
block error count."
::= { dsx3FarEndCurrentEntry 6 }
dsx3FarEndCurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
unavailable seconds."
::= { dsx3FarEndCurrentEntry 7 }
dsx3FarEndInvalidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of intervals in the range from 0 to
dsx3FarEndValidIntervals for which no data is
available. This object will typically be zero
except in cases where the data for some intervals
are not available (e.g., in proxy situations)."
::= { dsx3FarEndCurrentEntry 8 }
-- The DS3 Far End Interval Table
dsx3FarEndIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Far End Interval Table contains various
statistics collected by each DS3 interface over
the previous 24 hours of operation. The past 24
hours are broken into 96 completed 15 minute
intervals."
::= { ds3 11 }
dsx3FarEndIntervalEntry OBJECT-TYPE
SYNTAX Dsx3FarEndIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Far End Interval table."
INDEX { dsx3FarEndIntervalIndex,
dsx3FarEndIntervalNumber }
::= { dsx3FarEndIntervalTable 1 }
Dsx3FarEndIntervalEntry ::=
SEQUENCE {
dsx3FarEndIntervalIndex InterfaceIndex,
dsx3FarEndIntervalNumber INTEGER,
dsx3FarEndIntervalCESs PerfIntervalCount,
dsx3FarEndIntervalCSESs PerfIntervalCount,
dsx3FarEndIntervalCCVs PerfIntervalCount,
dsx3FarEndIntervalUASs PerfIntervalCount,
dsx3FarEndIntervalValidData TruthValue
}
dsx3FarEndIntervalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS3
interface to which this entry is applicable. The
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx3LineIndex."
::= { dsx3FarEndIntervalEntry 1 }
dsx3FarEndIntervalNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the 15 minutes interval completed 23 hours and 45
minutes prior to interval 1."
::= { dsx3FarEndIntervalEntry 2 }
dsx3FarEndIntervalCESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Errored Seconds encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals. In the case where the agent is
a proxy and data is not available, return
noSuchInstance."
::= { dsx3FarEndIntervalEntry 3 }
dsx3FarEndIntervalCSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Severely Errored Seconds."
::= { dsx3FarEndIntervalEntry 4 }
dsx3FarEndIntervalCCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Coding Violations reported via the far end
block error count."
::= { dsx3FarEndIntervalEntry 5 }
dsx3FarEndIntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
unavailable seconds."
::= { dsx3FarEndIntervalEntry 6 }
dsx3FarEndIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This variable indicates if the data for this
interval is valid."
::= { dsx3FarEndIntervalEntry 7 }
-- The DS3 Far End Total
dsx3FarEndTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Far End Total Table contains the
cumulative sum of the various statistics for the
24 hour period preceding the current interval."
::= { ds3 12 }
dsx3FarEndTotalEntry OBJECT-TYPE
SYNTAX Dsx3FarEndTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Far End Total table."
INDEX { dsx3FarEndTotalIndex }
::= { dsx3FarEndTotalTable 1 }
Dsx3FarEndTotalEntry ::=
SEQUENCE {
dsx3FarEndTotalIndex InterfaceIndex,
dsx3FarEndTotalCESs PerfTotalCount,
dsx3FarEndTotalCSESs PerfTotalCount,
dsx3FarEndTotalCCVs PerfTotalCount,
dsx3FarEndTotalUASs PerfTotalCount
}
dsx3FarEndTotalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS3
interface to which this entry is applicable. The
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx3LineIndex."
::= { dsx3FarEndTotalEntry 1 }
dsx3FarEndTotalCESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Errored Seconds encountered by a DS3
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3FarEndTotalEntry 2 }
dsx3FarEndTotalCSESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Severely Errored Seconds encountered by a
DS3 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx3FarEndTotalEntry 3 }
dsx3FarEndTotalCCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
C-bit Coding Violations reported via the far end
block error count encountered by a DS3 interface
in the previous 24 hour interval. Invalid 15
minute intervals count as 0."
::= { dsx3FarEndTotalEntry 4 }
dsx3FarEndTotalUASs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far End
unavailable seconds encountered by a DS3 interface
in the previous 24 hour interval. Invalid 15
minute intervals count as 0."
::= { dsx3FarEndTotalEntry 5 }
-- the DS3/E3 Fractional Table
-- This table is deprecated.
dsx3FracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3FracEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is deprecated in favour of using
ifStackTable.
Implementation of this table was optional. It was
designed for those systems dividing a DS3/E3 into
channels containing different data streams that
are of local interest.
The DS3/E3 fractional table identifies which
DS3/E3 channels associated with a CSU are being
used to support a logical interface, i.e., an
entry in the interfaces table from the Internet-
standard MIB.
For example, consider a DS3 device with 4 high
speed links carrying router traffic, a feed for
voice, a feed for video, and a synchronous channel
for a non-routed protocol. We might describe the
allocation of channels, in the dsx3FracTable, as
follows:
dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4
dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6
dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6
dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6
dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6
dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6
dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6
dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6
dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6
dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6
dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6
dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6
dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6
dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6
For dsx3M23, dsx3 SYNTRAN, dsx3CbitParity, and
dsx3ClearChannel there are 28 legal channels,
numbered 1 through 28.
For e3Framed there are 16 legal channels, numbered
1 through 16. The channels (1..16) correspond
directly to the equivalently numbered time-slots."
::= { ds3 13 }
dsx3FracEntry OBJECT-TYPE
SYNTAX Dsx3FracEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the DS3 Fractional table."
INDEX { dsx3FracIndex, dsx3FracNumber }
::= { dsx3FracTable 1 }
Dsx3FracEntry ::=
SEQUENCE {
dsx3FracIndex INTEGER,
dsx3FracNumber INTEGER,
dsx3FracIfIndex INTEGER
}
dsx3FracIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS3 interface to which this entry is applicable
The interface identified by a particular value
of this index is the same interface as
identified by the same value an dsx3LineIndex
object instance."
::= { dsx3FracEntry 1 }
dsx3FracNumber OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION
"The channel number for this entry."
::= { dsx3FracEntry 2 }
dsx3FracIfIndex OBJECT-TYPE
SYNTAX INTEGER (0..'7fffffff'h)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"An index value that uniquely identifies an
interface. The interface identified by a
particular value of this index is the same
interface as identified by the same value an
ifIndex object instance. If no interface is
currently using a channel, the value should be
zero. If a single interface occupies more than
one time slot, that ifIndex value will be found
in multiple time slots."
::= { dsx3FracEntry 3 }
-- DS3 TRAPS
ds3Traps OBJECT IDENTIFIER ::= { ds3 15 }
dsx3LineStatusChange NOTIFICATION-TYPE
OBJECTS { dsx3LineStatus,
dsx3LineStatusLastChange }
STATUS current
DESCRIPTION
"A dsx3LineStatusChange trap is sent when the
value of an instance of dsx3LineStatus changes. It
can be utilized by an NMS to trigger polls. When
the line status change results in a lower level
line status change (i.e., ds1), then no traps for
the lower level are sent."
::= { ds3Traps 0 1 }
-- conformance information
ds3Conformance OBJECT IDENTIFIER ::= { ds3 14 }
ds3Groups OBJECT IDENTIFIER ::= { ds3Conformance 1 }
ds3Compliances OBJECT IDENTIFIER ::= { ds3Conformance 2 }
-- compliance statements
ds3Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for DS3/E3 interfaces."
MODULE -- this module
MANDATORY-GROUPS { ds3NearEndConfigGroup,
ds3NearEndStatisticsGroup }
GROUP ds3FarEndGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS3 Interface. However,
only C-bit Parity and SYNTRAN DS3 applications
have the capability (option) of providing this
information."
GROUP ds3NearEndOptionalTrapGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS3 Interface. If it is
implemented then ds3NearEndOptionalConfigGroup
should also be implemented."
GROUP ds3NearEndOptionalConfigGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS3 interface."
OBJECT dsx3LineType
MIN-ACCESS read-only
DESCRIPTION
"Write access for the line type is not required."
OBJECT dsx3LineCoding
MIN-ACCESS read-only
DESCRIPTION
"Write access for the line coding is not
required."
OBJECT dsx3SendCode
MIN-ACCESS read-only
DESCRIPTION
"Write access for the send code is not required."
OBJECT dsx3LoopbackConfig
MIN-ACCESS read-only
DESCRIPTION
"Write access for loopbacks is not required."
OBJECT dsx3TransmitClockSource
MIN-ACCESS read-only
DESCRIPTION
"Write access for the transmit clock source is not
required."
OBJECT dsx3LineLength
MIN-ACCESS read-only
DESCRIPTION
"Write access for the line length is not
required."
OBJECT dsx3Channelization
MIN-ACCESS read-only
DESCRIPTION
"Write access for the channelization is not
required."
::= { ds3Compliances 1 }
-- units of conformance
ds3NearEndConfigGroup OBJECT-GROUP
OBJECTS { dsx3LineIndex,
dsx3TimeElapsed,
dsx3ValidIntervals,
dsx3LineType,
dsx3LineCoding,
dsx3SendCode,
dsx3CircuitIdentifier,
dsx3LoopbackConfig,
dsx3LineStatus,
dsx3TransmitClockSource,
dsx3InvalidIntervals,
dsx3LineLength,
dsx3LoopbackStatus,
dsx3Channelization,
dsx3Ds1ForRemoteLoop}
STATUS current
DESCRIPTION
"A collection of objects providing configuration
information applicable to all DS3/E3 interfaces."
::= { ds3Groups 1 }
ds3NearEndStatisticsGroup OBJECT-GROUP
OBJECTS { dsx3CurrentIndex,
dsx3CurrentPESs,
dsx3CurrentPSESs,
dsx3CurrentSEFSs,
dsx3CurrentUASs,
dsx3CurrentLCVs,
dsx3CurrentPCVs,
dsx3CurrentLESs,
dsx3CurrentCCVs,
dsx3CurrentCESs,
dsx3CurrentCSESs,
dsx3IntervalIndex,
dsx3IntervalNumber,
dsx3IntervalPESs,
dsx3IntervalPSESs,
dsx3IntervalSEFSs,
dsx3IntervalUASs,
dsx3IntervalLCVs,
dsx3IntervalPCVs,
dsx3IntervalLESs,
dsx3IntervalCCVs,
dsx3IntervalCESs,
dsx3IntervalCSESs,
dsx3IntervalValidData,
dsx3TotalIndex,
dsx3TotalPESs,
dsx3TotalPSESs,
dsx3TotalSEFSs,
dsx3TotalUASs,
dsx3TotalLCVs,
dsx3TotalPCVs,
dsx3TotalLESs,
dsx3TotalCCVs,
dsx3TotalCESs,
dsx3TotalCSESs }
STATUS current
DESCRIPTION
"A collection of objects providing statistics
information applicable to all DS3/E3 interfaces."
::= { ds3Groups 2 }
ds3FarEndGroup OBJECT-GROUP
OBJECTS { dsx3FarEndLineIndex,
dsx3FarEndEquipCode,
dsx3FarEndLocationIDCode,
dsx3FarEndFrameIDCode,
dsx3FarEndUnitCode,
dsx3FarEndFacilityIDCode,
dsx3FarEndCurrentIndex,
dsx3FarEndTimeElapsed,
dsx3FarEndValidIntervals,
dsx3FarEndCurrentCESs,
dsx3FarEndCurrentCSESs,
dsx3FarEndCurrentCCVs,
dsx3FarEndCurrentUASs,
dsx3FarEndInvalidIntervals,
dsx3FarEndIntervalIndex,
dsx3FarEndIntervalNumber,
dsx3FarEndIntervalCESs,
dsx3FarEndIntervalCSESs,
dsx3FarEndIntervalCCVs,
dsx3FarEndIntervalUASs,
dsx3FarEndIntervalValidData,
dsx3FarEndTotalIndex,
dsx3FarEndTotalCESs,
dsx3FarEndTotalCSESs,
dsx3FarEndTotalCCVs,
dsx3FarEndTotalUASs }
STATUS current
DESCRIPTION
"A collection of objects providing remote
configuration and statistics information
applicable to C-bit Parity and SYNTRAN DS3
interfaces."
::= { ds3Groups 3 }
ds3DeprecatedGroup OBJECT-GROUP
OBJECTS { dsx3IfIndex,
dsx3FracIndex,
dsx3FracNumber,
dsx3FracIfIndex }
STATUS deprecated
DESCRIPTION
"A collection of obsolete objects that may be
implemented for backwards compatibility."
::= { ds3Groups 4 }
ds3NearEndOptionalConfigGroup OBJECT-GROUP
OBJECTS { dsx3LineStatusLastChange,
dsx3LineStatusChangeTrapEnable }
STATUS current
DESCRIPTION
"A collection of objects that may be implemented
on DS3/E3 interfaces."
::= { ds3Groups 5 }
ds3NearEndOptionalTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS { dsx3LineStatusChange }
STATUS current
DESCRIPTION
"A collection of notifications that may be
implemented on DS3/E3 interfaces."
::= { ds3Groups 6 }
END