Printer-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, TimeTicks,
NOTIFICATION-TYPE, OBJECT-IDENTITY,
mib-2 FROM SNMPv2-SMI -- [RFC2578]
TEXTUAL-CONVENTION FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- [RFC2580]
hrDeviceIndex, hrStorageIndex FROM HOST-RESOURCES-MIB -- [RFC2790]
InterfaceIndexOrZero FROM IF-MIB -- [RFC2863]
PrtCoverStatusTC, PrtGeneralResetTC, PrtChannelTypeTC,
PrtInterpreterLangFamilyTC, PrtInputTypeTC, PrtOutputTypeTC,
PrtMarkerMarkTechTC, PrtMarkerSuppliesTypeTC, PrtConsoleColorTC,
PrtConsoleDisableTC, PrtMediaPathTypeTC, PrtAlertGroupTC,
PrtAlertTrainingLevelTC, PrtAlertCodeTC
FROM IANA-PRINTER-MIB
IANACharset FROM IANA-CHARSET-MIB;
printmib MODULE-IDENTITY
LAST-UPDATED "0406020000Z"
ORGANIZATION "PWG IEEE/ISTO Printer Working Group"
CONTACT-INFO
"Harry Lewis
IBM
Phone (303) 924-5337
Email: harryl@us.ibm.com
http://www.pwg.org/index.html
Send comments to the printmib WG using the Printer MIB
Project (PMP) Mailing List: pmp@pwg.org
For further information, access the PWG web page under 'Printer
MIB': http://www.pwg.org/
Implementers of this specification are encouraged to join the
pmp mailing list in order to participate in discussions on any
clarifications needed and registration proposals being reviewed
in order to achieve consensus."
DESCRIPTION
"The MIB module for management of printers.
Copyright (C) The Internet Society (2004). This
version of this MIB module was published
in RFC 3805. For full legal notices see the RFC itself."
REVISION "200406020000Z"
DESCRIPTION
"Printer MIB v2.
Moved all enum groups to be maintained by IANA into new TCs
within the ianaPrinterMIB, which is contained in this
document.
New TCs created from enums defined within RFC 1759 Objects:
PrtPrintOrientationTC, PrtLocalizedDescriptionStringTC,
PrtConsoleDescriptionStringTC, PrtChannelStateTC,
PrtOutputStackingOrderTC, PrtOutputPageDeliveryOrientationTC,
PrtMarkerCounterUnitTC, PrtMarkerSuppliesSupplyUnitTC,
PrtMarkerSuppliesClassTC, PrtMarkerAddressabilityUnitTC,
PrtMarkerColorantRoleTC, PrtMediaPathMaxSpeedPrintUnitTC,
PrtInterpreterTwoWayTC, and PrtAlertSeverityLevelTC.
The following four TCs have been deprecated:
MediaUnit (replaced by PrtMediaUnitTC),
CapacityUnit (replaced by PrtCapacityUnitTC),
SubUnitStatus (replaced by PrtSubUnitStatusTC),
CodedCharSet (replaced by IANACharset in IANA Charset MIB)
Five new OBJECT-GROUPs: prtAuxilliarySheetGroup,
prtInputSwitchingGroup, prtGeneralV2Group,
prtAlertTableV2Group, prtChannelV2Group.
Nine new objects added to those groups:
prtAuxiliarySheetStartupPage, prtAuxiliarySheetBannerPage,
prtGeneralPrinterName, prtGeneralSerialNumber,
prtAlertCriticalEvents, prtAlertAllEvents,
prtInputMediaLoadTimeout, prtInputNextIndex,
prtChannelInformation.
SYNTAX range changed from (0..65535) to (1..65535) for the
index objects prtStorageRefSeqNumber, prtDeviceRefSeqNumber,
and prtConsoleLightIndex.
SYNTAX range changed from (0..65535) to (0..2147483647) for the
objects prtStorageRefIndex and prtDeviceRefIndex to agree
with the Host Resources MIB.
Defined a range for the objects with a SYNTAX of Integer32:
prtOutputDefaultIndex, prtInputMediaDimFeedDirDeclared,
prtInputMediaDimXFeedDirDeclared, prtInputMaxCapacity,
prtInputCurrentLevel, prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
prtInputMediaFormParts, prtOutputIndex,
prtOutputMaxCapacity, prtOutputRemainingCapacity,
prtOutputMaxDimFeedDir, prtOutputMaxDimXFeedDir,
prtOutputMinDimFeedDir, prtOutputMinDimXFeedDir,
prtMarkerAddressibilityFeedDir,
prtMarkerAddressibilityXFeedDir, prtMarkerNorthMargin,
prtMarkerSouthMargin, prtMarkerWestMargin,
prtMarkerEastMargin, prtMarkerSuppliesMaxCapacity,
prtMarkerSuppliesLevel, prtMarkerColorantTonality,
prtMediaPathMaxSpeed, prtMediaPathMaxMediaFeedDir,
prtMediaPathMaxMediaXFeedDir, prtMediaPathMinMediaFeedDir,
prtMediaPathMinMediaXFeedDir, prtChannelIndex,
prtChannelCurrentJobCntlLangIndex, prtInterpreterIndex,
prtChannelDefaultPageDescLangIndex, prtConsoleOnTime,
prtInterpreterFeedAddressibility, prtConsoleOffTime,
prtInterpreterXFeedAddressibility, prtAlertIndex,
prtAlertGroupIndex, prtAlertLocation.
Changed SYNTAX from Integer32 to InterfaceIndexOrZero for
prtChannelIfIndex.
Changed MAX-ACCESS of prtAlertIndex from not-accessible to
Read-only and added a compliance statement to allow a
MIN-ACCESS of accessible-for-notify.
One new NOTIFICATION-GROUP: prtAlertTrapGroup which contains
printerV2Alert.
In MODULE-COMPLIANCE prtMIBCompliance, new OBJECT-GROUPs and
the NOTIFICATION_GROUP, all in GROUP (not MANDATORY-GROUP)
clauses. The nine new objects are optional, i.e., this
document is backward compatible with RFC 1759."
REVISION "9411250000Z"
DESCRIPTION
"The original version of this MIB, published as RFC1759."
::= { mib-2 43 }
-- TEXTUAL-CONVENTIONs for this MIB module
--
-- Generic unspecific TEXTUAL-CONVENTIONs
--
PrtMediaUnitTC ::= TEXTUAL-CONVENTION
-- Replaces MediaUnit in RFC 1759.
STATUS current
DESCRIPTION
"Units of measure for media dimensions."
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4)
}
MediaUnit ::= TEXTUAL-CONVENTION
-- Replaced by PrtMediaUnitTC.
STATUS deprecated
DESCRIPTION
"Units of measure for media dimensions."
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4)
}
PrtCapacityUnitTC ::= TEXTUAL-CONVENTION
-- Replaces CapacityUnit in RFC 1759.
STATUS current
DESCRIPTION
"Units of measure for media capacity."
SYNTAX INTEGER {
other(1), -- New, not in RFC 1759
unknown(2), -- New, not in RFC 1759
tenThousandthsOfInches(3), -- .0001
micrometers(4),
sheets(8),
feet(16),
meters(17),
-- Values for Finisher MIB
items(18), -- New, not in RFC 1759
percent(19) -- New, not in RFC 1759
}
CapacityUnit ::= TEXTUAL-CONVENTION
-- Replaced by PrtCapacityUnitTC.
STATUS deprecated
DESCRIPTION
"Units of measure for media capacity."
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4),
sheets(8),
feet(16),
meters(17)
}
PrtPrintOrientationTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtInterpreterDefaultOrientation in
-- RFC 1759.
STATUS current
DESCRIPTION
"A generic representation for printing orientation on a
'page'."
SYNTAX INTEGER {
other(1),
portrait(3),
landscape(4)
}
PrtSubUnitStatusTC ::= TEXTUAL-CONVENTION
-- Replaces SubUnitStatus in RFC 1759.
STATUS current
DESCRIPTION
"Status of a printer sub-unit.
The SubUnitStatus is an integer that is the sum of 5 distinct
values, Availability, Non-Critical, Critical, On-line, and
Transitioning. These values are:
Availability Value
Available and Idle 0 0000'b
Available and Standby 2 0010'b
Available and Active 4 0100'b
Available and Busy 6 0110'b
Unavailable and OnRequest 1 0001'b
Unavailable because Broken 3 0011'b
Unknown 5 0101'b
Non-Critical
No Non-Critical Alerts 0 0000'b
Non-Critical Alerts 8 1000'b
Critical
No Critical Alerts 0 0000'b
Critical Alerts 16 1 0000'b
On-Line
State is On-Line 0 0000'b
State is Off-Line 32 10 0000'b
Transitioning
At intended state 0 0000'b
Transitioning to intended state 64 100 0000'b"
SYNTAX INTEGER (0..126)
SubUnitStatus ::= TEXTUAL-CONVENTION
-- Replaced by PrtSubUnitStatusTC.
STATUS deprecated
DESCRIPTION
"Status of a printer sub-unit.
The SubUnitStatus is an integer that is the sum of 5 distinct
values, Availability, Non-Critical, Critical, On-line, and
Transitioning. These values are:
Availability Value
Available and Idle 0 0000'b
Available and Standby 2 0010'b
Available and Active 4 0100'b
Available and Busy 6 0110'b
Unavailable and OnRequest 1 0001'b
Unavailable because Broken 3 0011'b
Unknown 5 0101'b
Non-Critical
No Non-Critical Alerts 0 0000'b
Non-Critical Alerts 8 1000'b
Critical
No Critical Alerts 0 0000'b
Critical Alerts 16 1 0000'b
On-Line
State is On-Line 0 0000'b
State is Off-Line 32 10 0000'b
Transitioning
At intended state 0 0000'b
Transitioning to intended state 64 100 0000'b"
SYNTAX INTEGER (0..126)
PresentOnOff ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Presence and configuration of a device or feature."
SYNTAX INTEGER {
other(1),
on(3),
off(4),
notPresent(5)
}
PrtLocalizedDescriptionStringTC ::= TEXTUAL-CONVENTION
-- This TC did not appear in RFC 1759.
STATUS current
DESCRIPTION
"An object MUST use this TEXTUAL-CONVENTION when its
'charset' is controlled by the value of
prtGeneralCurrentLocalization."
SYNTAX OCTET STRING (SIZE(0..255))
PrtConsoleDescriptionStringTC ::= TEXTUAL-CONVENTION
-- This TC did not appear in RFC 1759.
STATUS current
DESCRIPTION
"An object MUST use this TEXTUAL-CONVENTION when its
'charset' is controlled by the value of
prtConsoleLocalization."
SYNTAX OCTET STRING (SIZE(0..255))
CodedCharSet ::= TEXTUAL-CONVENTION
-- Replaced by IANACharset TEXTUAL-CONVENTION in IANA Charset MIB.
STATUS deprecated
DESCRIPTION
"The original description clause from RFC 1759 [RFC1759] was
technically inaccurate and therefore has been deleted."
SYNTAX INTEGER {
other(1) -- used if the designated coded
-- character set is not currently in
-- the enumeration
}
--
-- Channel Group TEXTUAL-CONVENTIONs
--
PrtChannelStateTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtChannelState in RFC 1759.
STATUS current
DESCRIPTION
"The state of this print job delivery channel. The value
determines whether print data is allowed through this channel."
SYNTAX INTEGER {
other(1),
printDataAccepted(3),
noDataAccepted(4)
}
--
-- Input/Output Group TEXTUAL-CONVENTIONs
--
PrtOutputStackingOrderTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtOutputStackingOrder in RFC 1759.
STATUS current
DESCRIPTION
"The current state of the stacking order for the associated
output sub-unit. 'firstToLast' means that as pages are output,
the front of the next page is placed against the back of the
previous page. 'lastToFirst' means that as pages are output,
the back of the next page is placed against the front of the
previous page."
SYNTAX INTEGER {
unknown(2),
firstToLast(3),
lastToFirst(4)
}
PrtOutputPageDeliveryOrientationTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtOutputPageDeliveryOrientation
-- in RFC 1759.
STATUS current
DESCRIPTION
"The reading surface that will be 'up' when pages are delivered
to the associated output sub-unit. Values are Face-Up and Face
Down (Note: interpretation of these values is, in general,
context-dependent based on locale; presentation of these values
to an end-user should be normalized to the expectations of the
user."
SYNTAX INTEGER {
faceUp(3),
faceDown(4)
}
--
-- Marker Group TEXTUAL-CONVENTIONs
--
PrtMarkerCounterUnitTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerCounterUnit in RFC 1759.
STATUS current
DESCRIPTION
"The unit that will be used by the printer when reporting
counter values for this marking sub-unit. The
time units of measure are provided for a device like a
strip recorder that does not or cannot track the physical
dimensions of the media and does not use characters,
lines or sheets."
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4),
characters(5),
lines(6),
impressions(7),
sheets(8),
dotRow(9),
hours(11),
feet(16),
meters(17)
}
PrtMarkerSuppliesSupplyUnitTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerSuppliesSupplyUnit
-- in RFC 1759.
STATUS current
DESCRIPTION
"Unit of this marker supply container/receptacle."
SYNTAX INTEGER {
other(1), -- New, not in RFC 1759
unknown(2), -- New, not in RFC 1759
tenThousandthsOfInches(3), -- .0001
micrometers(4),
impressions(7), -- New, not in RFC 1759
sheets(8), -- New, not in RFC 1759
hours(11), -- New, not in RFC 1759
thousandthsOfOunces(12),
tenthsOfGrams(13),
hundrethsOfFluidOunces(14),
tenthsOfMilliliters(15),
feet(16), -- New, not in RFC 1759
meters(17), -- New, not in RFC 1759
-- Values for Finisher MIB
items(18), -- e.g., #staples. New, not in RFC 1759
percent(19) -- New, not in RFC 1759
}
PrtMarkerSuppliesClassTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerSuppliesClass in RFC 1759.
STATUS current
DESCRIPTION
"Indicates whether this supply entity represents a supply
that is consumed or a receptacle that is filled."
SYNTAX INTEGER {
other(1),
supplyThatIsConsumed(3),
receptacleThatIsFilled(4)
}
PrtMarkerColorantRoleTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerColorantRole in RFC 1759.
STATUS current
DESCRIPTION
"The role played by this colorant."
SYNTAX INTEGER { -- Colorant Role
other(1),
process(3),
spot(4)
}
PrtMarkerAddressabilityUnitTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerAddressabilityUnit
-- in RFC 1759.
STATUS current
DESCRIPTION
"The unit of measure of distances, as applied to the marker's
resolution."
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4)
}
--
-- Media Path TEXTUAL-CONVENTIONs
--
PrtMediaPathMaxSpeedPrintUnitTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMediaPathMaxSpeedPrintUnit
-- in RFC 1759.
STATUS current
DESCRIPTION
"The unit of measure used in specifying the speed of all
media paths in the printer."
SYNTAX INTEGER {
tenThousandthsOfInchesPerHour(3),-- .0001/hour
micrometersPerHour(4),
charactersPerHour(5),
linesPerHour(6),
impressionsPerHour(7),
sheetsPerHour(8),
dotRowPerHour(9),
feetPerHour(16),
metersPerHour(17)
}
--
-- Interpreter Group TEXTUAL-CONVENTIONs
--
PrtInterpreterTwoWayTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtInterpreterTwoWay in RFC 1759.
STATUS current
DESCRIPTION
"Indicates whether or not this interpreter returns information
back to the host."
SYNTAX INTEGER {
yes(3),
no(4)
}
--
-- Alert Group TEXTUAL-CONVENTIONs
--
PrtAlertSeverityLevelTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtAlertSeverityLevel in RFC 1759.
STATUS current
DESCRIPTION
"The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry in the
table. A critical alert is binary by nature and definition. A
warning is defined to be a non-critical alert. The original and
most common warning is unary. The binary warning was added later
and given a more distinguished name."
SYNTAX INTEGER {
other(1),
critical(3),
warning(4),
warningBinaryChangeEvent(5) -- New, not in RFC 1759
}
-- The General Printer Group
--
-- The general printer sub-unit is responsible for the overall
-- control and status of the printer. There is exactly one
-- general printer sub-unit in a printer.
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
prtGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of general information per printer.
Objects in this table are defined in various
places in the MIB, nearby the groups to
which they apply. They are all defined
here to minimize the number of tables that would
otherwise need to exist."
::= { prtGeneral 1 }
prtGeneralEntry OBJECT-TYPE
SYNTAX PrtGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry exists in this table for each device entry in the
host resources MIB device table with a device type of
'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex }
::= { prtGeneralTable 1 }
PrtGeneralEntry ::= SEQUENCE {
-- Note that not all of the objects in this sequence are in
-- the general printer group. The group to which an
-- object belongs is tagged with a label "General", "Input"
-- "Output", etc. after each entry in the following sequence.
--
prtGeneralConfigChanges Counter32, -- General
prtGeneralCurrentLocalization Integer32, -- General
prtGeneralReset PrtGeneralResetTC,
-- General
prtGeneralCurrentOperator OCTET STRING,
-- Responsible Party
prtGeneralServicePerson OCTET STRING,
-- Responsible Party
prtInputDefaultIndex Integer32, -- Input
prtOutputDefaultIndex Integer32, -- Output
prtMarkerDefaultIndex Integer32, -- Marker
prtMediaPathDefaultIndex Integer32, -- Media Path
prtConsoleLocalization Integer32, -- Console
prtConsoleNumberOfDisplayLines Integer32, -- Console
prtConsoleNumberOfDisplayChars Integer32, -- Console
prtConsoleDisable PrtConsoleDisableTC,
-- Console,
prtAuxiliarySheetStartupPage PresentOnOff,
-- AuxiliarySheet
prtAuxiliarySheetBannerPage PresentOnOff,
-- AuxiliarySheet
prtGeneralPrinterName OCTET STRING,
-- General V2
prtGeneralSerialNumber OCTET STRING,
-- General V2
prtAlertCriticalEvents Counter32, -- Alert V2
prtAlertAllEvents Counter32 -- Alert V2
}
prtGeneralConfigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts configuration changes within the printer. A
configuration change is defined to be an action that results in
a change to any MIB object other than those that reflect status
or level, or those that act as counters or gauges. In addition,
any action that results in a row being added or deleted from
any table in the Printer MIB is considered a configuration
change. Such changes will often affect the capability of the
printer to service certain types of print jobs. Management
applications may cache infrequently changed configuration
information about sub units within the printer. This object
should be incremented whenever the agent wishes to notify
management applications that any cached configuration
information for this device is to be considered 'stale'. At
this point, the management application should flush any
configuration information cached about this device and fetch
new configuration information.
The following are examples of actions that would cause the
prtGeneralConfigChanges object to be incremented:
- Adding an output bin
- Changing the media in a sensing input tray
- Changing the value of prtInputMediaType
Note that the prtGeneralConfigChanges counter would not be
incremented when an input tray is temporarily removed to load
additional paper or when the level of an input device changes.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 1 }
prtGeneralCurrentLocalization OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to the
current language, country, and character set to be used for
localized string values that are identified as being dependent
on the value of this object. Note that this object does not
apply to localized strings in the prtConsole group or to any
object that is not explicitly identified as being localized
according to prtGeneralCurrentLocalization. When an object's
'charset' is controlled by the value of
prtGeneralCurrentLocalization, it MUST specify
PrtLocalizedDescriptionStringTC as its syntax.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 2 }
prtGeneralReset OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
-- by this object.
SYNTAX PrtGeneralResetTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to 'powerCycleReset', 'resetToNVRAM', or
'resetToFactoryDefaults' will result in the resetting of the
printer. When read, this object will always have the value
'notResetting(3)', and a SET of the value 'notResetting' shall
have no effect on the printer. Some of the defined values are
optional. However, every implementation must support at least
the values 'notResetting' and 'resetToNVRAM'."
::= { prtGeneralEntry 3 }
-- The Responsible Party group
prtGeneralCurrentOperator OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the person who is responsible for operating
this printer. It is suggested that this string include
information that would enable other humans to reach the
operator, such as a phone number. As a convention to
facilitate automatic notification of the operator by the
agent or network management station, the phone number,
fax number or email address should be indicated by the
URL schemes 'tel:', 'fax:' and 'mailto:', respectively.
If either the phone, fax, or email information is not
available, then a line should not be included for this
information.
NOTE: For interoperability purposes, it is advisable to
use email addresses formatted according to [RFC2822]
requirements.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 4 }
prtGeneralServicePerson OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the person responsible for servicing this
printer. It is suggested that this string include
information that would enable other humans to reach the
service person, such as a phone number. As a convention
to facilitate automatic notification of the operator by
the agent or network management station, the phone
number, fax number or email address should be indicated
by the URL schemes 'tel:', 'fax:' and 'mailto:',
respectively. If either the phone, fax, or email
information is not available, then a line should not
be included for this information.
NOTE: For interoperability purposes, it is advisable to use
email addresses formatted per [RFC2822] requirements.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 5 }
-- Default indexes section
--
-- The following four objects are used to specify the indexes of
-- certain subunits used as defaults during the printing process.
prtInputDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInputIndex corresponding to the default input
sub-unit: that is, this object selects the default source of
input media."
::= { prtGeneralEntry 6 }
prtOutputDefaultIndex OBJECT-TYPE
-- A range has been added to the SYNTAX clause that was not in
-- RFC 1759. Although this violates SNMP compatibility rules,
-- it provides a more reasonable guide for SNMP managers.
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtOutputIndex corresponding to the default
output sub-unit; that is, this object selects the default
output destination."
::= { prtGeneralEntry 7 }
prtMarkerDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
default marker sub-unit; that is, this object selects the
default marker."
::= { prtGeneralEntry 8 }
prtMediaPathDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtMediaPathIndex corresponding to
the default media path; that is, the selection of the
default media path."
::= { prtGeneralEntry 9 }
-- Console general section
--
-- The following four objects describe overall parameters of the
-- printer console subsystem.
prtConsoleLocalization OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to
the language, country, and character set to be used for the
console. This localization applies both to the actual display
on the console as well as the encoding of these console objects
in management operations. When an object's 'charset' is
controlled by the value of prtConsoleLocalization, it MUST
specify PrtConsoleDescriptionStringTC as its syntax.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 10 }
prtConsoleNumberOfDisplayLines OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of lines on the printer's physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display"
::= { prtGeneralEntry 11 }
prtConsoleNumberOfDisplayChars OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of characters per line displayed on the physical
display. This value is 0 if there are no lines on the physical
display or if there is no physical display"
::= { prtGeneralEntry 12 }
prtConsoleDisable OBJECT-TYPE
-- In RFC 1759, the enumeration values were implicitly defined
-- by this object.
SYNTAX PrtConsoleDisableTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates how input is (or is not) accepted from
the operator console.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneralEntry 13 }
-- The Auxiliary Sheet Group
--
-- The auxiliary sheet group allows the administrator to control
-- the production of auxiliary sheets by the printer. This group
-- contains only the "prtAuxiliarySheetStartupPage" and
-- "prtAuxiliarySheetBannerPage" objects.
prtAuxiliarySheetStartupPage OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to enable or disable printing a startup page. If enabled,
a startup page will be printed shortly after power-up, when the
device is ready. Typical startup pages include test patterns
and/or printer configuration information."
::= { prtGeneralEntry 14 }
prtAuxiliarySheetBannerPage OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to enable or disable printing banner pages at the
beginning of jobs. This is a master switch which applies to all
jobs, regardless of interpreter."
::= { prtGeneralEntry 15 }
-- Administrative section (The General V2 Group)
--
-- The following two objects are used to specify administrative
-- information assigned to the printer.
prtGeneralPrinterName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An administrator-specified name for this printer. Depending
upon implementation of this printer, the value of this object
may or may not be same as the value for the MIB-II 'SysName'
object."
::= { prtGeneralEntry 16 }
prtGeneralSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A recorded serial number for this device that indexes some
type device catalog or inventory. This value is usually set by
the device manufacturer but the MIB supports the option of
writing for this object for site-specific administration of
device inventory or tracking."
::= { prtGeneralEntry 17 }
-- General alert table section (Alert Table V2 Group)
--
-- The following two objects are used to specify counters
-- associated with the Alert Table.
prtAlertCriticalEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running counter of the number of critical alert events that
have been recorded in the alert table. The value of this object
is RESET in the event of a power cycle operation (i.e., the
value is not persistent."
::= { prtGeneralEntry 18 }
prtAlertAllEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running counter of the total number of alert event entries
(critical and non-critical) that have been recorded in the
alert table"
::= { prtGeneralEntry 19 }
-- The Cover Table
--
-- The cover portion of the General print sub-unit describes the
-- covers and interlocks of the printer. The Cover Table has an
-- entry for each cover and interlock.
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
prtCoverTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCoverEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the covers and interlocks of the printer."
::= { prtCover 1 }
prtCoverEntry OBJECT-TYPE
SYNTAX PrtCoverEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a cover or interlock.
Entries may exist in the table for each device
index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtCoverIndex }
::= { prtCoverTable 1 }
PrtCoverEntry ::= SEQUENCE {
prtCoverIndex Integer32,
prtCoverDescription PrtLocalizedDescriptionStringTC,
prtCoverStatus PrtCoverStatusTC
}
prtCoverIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this Cover sub
unit. Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new cover
sub-units to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtCoverEntry 1 }
prtCoverDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturer provided cover sub-mechanism name in the
localization specified by prtGeneralCurrentLocalization."
::= { prtCoverEntry 2 }
prtCoverStatus OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
-- by this object and are now defined in the IANA-PRINTER-MIB. The
-- new TC has defined "coverOpen" and "coverClosed" to replace
-- "doorOpen" and "doorClosed" in RFC 1759. A name change is not
-- formally allowed per SMI rules, but was agreed to by the WG group
-- since a door has a more restrictive meaning than a cover and
-- Cover group is intended to support doors as a subset of covers.
SYNTAX PrtCoverStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this cover sub-unit."
::= { prtCoverEntry 3 }
-- The Localization Table
--
-- The localization portion of the General printer sub-unit is
-- responsible for identifying the natural language, country, and
-- character set in which character strings are expressed. There
-- may be one or more localizations supported per printer. The
-- available localizations are represented by the Localization
-- table.
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
prtLocalizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLocalizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The available localizations in this printer."
::= { prtLocalization 1 }
prtLocalizationEntry OBJECT-TYPE
SYNTAX PrtLocalizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A description of a localization.
Entries may exist in the table for each device
index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtLocalizationIndex }
::= { prtLocalizationTable 1 }
PrtLocalizationEntry ::= SEQUENCE {
prtLocalizationIndex Integer32,
prtLocalizationLanguage OCTET STRING,
prtLocalizationCountry OCTET STRING,
prtLocalizationCharacterSet IANACharset
}
prtLocalizationIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this
localization entry. Although these values may change due to a
major reconfiguration of the device (e.g., the addition of new
localization data to the printer), values SHOULD remain
stable across successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtLocalizationEntry 1 }
prtLocalizationLanguage OBJECT-TYPE
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A two character language code from ISO 639. Examples en,
es, fr, de. NOTE: These examples were shown as upper case in
RFC 1759 and are now shown as lower case to agree with ISO 639."
::= { prtLocalizationEntry 2 }
prtLocalizationCountry OBJECT-TYPE
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A two character country code from ISO 3166, a blank string
(two space characters) shall indicate that the country is not
defined. Examples: US, GB, FR, DE, ..."
::= { prtLocalizationEntry 3 }
prtLocalizationCharacterSet OBJECT-TYPE
SYNTAX IANACharset
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The coded character set used for this localization."
::= { prtLocalizationEntry 4 }
-- The System Resources Tables
--
-- The Printer MIB makes use of the Host Resources MIB to
-- define system resources by referencing the storage
-- and device groups of the print group.
prtStorageRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtStorageRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines which printer, amongst multiple printers
serviced by one agent, owns which storage units.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneral 2 }
prtStorageRefEntry OBJECT-TYPE
SYNTAX PrtStorageRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table will have an entry for each entry in the Host
Resources MIB storage table that represents storage associated
with a printer managed by this agent.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrStorageIndex, prtStorageRefSeqNumber }
::= { prtStorageRefTable 1 }
PrtStorageRefEntry ::= SEQUENCE {
prtStorageRefSeqNumber Integer32,
prtStorageRefIndex Integer32
}
prtStorageRefSeqNumber OBJECT-TYPE
-- NOTE: The range has been changed from RFC 1759, which allowed a
-- minumum value of zero. This was incorrect, since zero is not a
-- valid index.
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This value will be unique amongst all entries with a common
value of hrStorageIndex. This object allows a storage entry to
point to the multiple printer devices with which it is
associated."
::= { prtStorageRefEntry 1 }
prtStorageRefIndex OBJECT-TYPE
-- NOTE: The range has been changed from RFC 1759 to be compatible
-- with the defined range of hrDeviceIndex.
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
storageEntry is associated with."
::= { prtStorageRefEntry 2 }
prtDeviceRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDeviceRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines which printer, amongst multiple printers
serviced by one agent, is associated with which devices.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtGeneral 3 }
prtDeviceRefEntry OBJECT-TYPE
SYNTAX PrtDeviceRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table will have an entry for each entry in the Host
Resources MIB device table that represents a device associated
with a printer managed by this agent.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtDeviceRefSeqNumber }
::= { prtDeviceRefTable 1 }
PrtDeviceRefEntry ::= SEQUENCE {
prtDeviceRefSeqNumber Integer32,
prtDeviceRefIndex Integer32
}
prtDeviceRefSeqNumber OBJECT-TYPE
-- NOTE: The range has been changed from RFC 1759, which allowed a
-- minumum value of zero. This was incorrect, since zero is not a
-- valid index.
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This value will be unique amongst all entries with a common
value of hrDeviceIndex. This object allows a device entry to
point to the multiple printer devices with which it is
associated."
::= { prtDeviceRefEntry 1 }
prtDeviceRefIndex OBJECT-TYPE
-- NOTE: The range has been changed from RFC 1759 to be compatible
-- with the defined range of hrDeviceIndex.
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
deviceEntry is associated with."
::= { prtDeviceRefEntry 2 }
-- The Input Group
--
-- Input sub-units are managed as a tabular, indexed collection
-- of possible devices capable of providing media for input to
-- the printing process. Input sub-units typically have a
-- location, a type, an identifier, a set of constraints on
-- possible media sizes and potentially other media
-- characteristics, and may be capable of indicating current
-- status or capacity.
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
prtInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the devices capable of providing media for input to
the printing process."
::= { prtInput 2 }
prtInputEntry OBJECT-TYPE
SYNTAX PrtInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a device capable of providing media for input to
the printing process. Entries may exist in the table for each
device index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtInputIndex }
::= { prtInputTable 1 }
PrtInputEntry ::= SEQUENCE {
prtInputIndex Integer32,
prtInputType PrtInputTypeTC,
prtInputDimUnit PrtMediaUnitTC,
prtInputMediaDimFeedDirDeclared Integer32,
prtInputMediaDimXFeedDirDeclared Integer32,
prtInputMediaDimFeedDirChosen Integer32,
prtInputMediaDimXFeedDirChosen Integer32,
prtInputCapacityUnit PrtCapacityUnitTC,
prtInputMaxCapacity Integer32,
prtInputCurrentLevel Integer32,
prtInputStatus PrtSubUnitStatusTC,
prtInputMediaName OCTET STRING,
prtInputName OCTET STRING,
prtInputVendorName OCTET STRING,
prtInputModel OCTET STRING,
prtInputVersion OCTET STRING,
prtInputSerialNumber OCTET STRING,
prtInputDescription PrtLocalizedDescriptionStringTC,
prtInputSecurity PresentOnOff,
prtInputMediaWeight Integer32,
prtInputMediaType OCTET STRING,
prtInputMediaColor OCTET STRING,
prtInputMediaFormParts Integer32,
prtInputMediaLoadTimeout Integer32,
prtInputNextIndex Integer32
}
prtInputIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this input
sub-unit. Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new input
sub-units to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInputEntry 1 }
prtInputType OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtInputTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of technology (discriminated primarily according to
feeder mechanism type) employed by the input sub-unit. Note,
the Input Class provides for a descriptor field to further
qualify the other choice."
::= { prtInputEntry 2 }
prtInputDimUnit OBJECT-TYPE
SYNTAX PrtMediaUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use calculating and relaying
dimensional values for this input sub-unit."
::= { prtInputEntry 3 }
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the value of the declared dimension, in
the feed direction, of the media that is (or, if empty, was or
will be) in this input sub-unit. The feed direction is the
direction in which the media is fed on this sub-unit. This
dimension is measured in input sub-unit dimensional units
(controlled by prtInputDimUnit, which uses PrtMediaUnitTC). If
this input sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests. Otherwise, the value may be changed. The value (-1)
means other and specifically means that this sub-unit places no
restriction on this parameter. The value (-2) indicates
unknown."
::= { prtInputEntry 4 }
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the value of the declared dimension, in
the cross feed direction, of the media that is (or, if empty,
was or will be) in this input sub-unit. The cross feed
direction is ninety degrees relative to the feed direction
associated with this sub-unit. This dimension is measured in
input sub-unit dimensional units (controlled by
prtInputDimUnit,which uses PrtMediaUnitTC). If this input sub-
unit can reliably sense this value, the value is sensed by the
printer and may not be changed by management requests.
Otherwise, the value may be changed. The value (-1) means other
and specifically means that this sub-unit places no restriction
on this parameter. The value (-2) indicates unknown."
::= { prtInputEntry 5 }
prtInputMediaDimFeedDirChosen OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the feed direction) is present in this input source. Note that
this value will be used even if the input tray is empty. Feed
dimension measurements are taken relative to the feed direction
associated with that sub-unit and are in input sub-unit
dimensional units (controlled by prtInputDimUnit, which uses
PrtMediaUnitTC). If the printer supports the declared
dimension,the granted dimension is the same as the declared
dimension. If not, the granted dimension is set to the closest
dimension that the printer supports when the declared dimension
is set. The value (-1) means other and specifically indicates
that this sub-unit places no restriction on this parameter. The
value (-2)indicates unknown."
::= { prtInputEntry 6 }
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the cross feed direction) is present in this input source. Note
that this value will be used even if the input tray is empty.
The cross feed direction is ninety degrees relative to the feed
direction associated with this sub-unit. This dimension is
measured in input sub-unit dimensional units (controlled by
prtInputDimUnit, which uses PrtMediaUnitTC). If the printer
supports the declare dimension, the granted dimension is the
same as the declared dimension. If not, the granted dimension
is set to the closest dimension that the printer supports when
the declared dimension is set. The value (-1) means other and
specifically indicates that this sub-unit places no restriction
on this parameter. The value (-2) indicates unknown."
::= { prtInputEntry 7 }
prtInputCapacityUnit OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtCapacityUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this input sub-unit."
::= { prtInputEntry 8 }
prtInputMaxCapacity OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of the input sub-unit in input sub-unit
capacity units (PrtCapacityUnitTC). There is no convention
associated with the media itself so this value reflects claimed
capacity. If this input sub-unit can reliably sense this value,
the value is sensed by the printer and may not be changed by
management requests; otherwise, the value may be written (by a
Remote Control Panel or a Management Application). The value
(-1) means other and specifically indicates that the sub-unit
places no restrictions on this parameter. The value (-2) means
unknown."
::= { prtInputEntry 9 }
prtInputCurrentLevel OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-3..2147483647) -- in capacity units
-- (PrtCapacityUnitTC).
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current capacity of the input sub-unit in input sub-unit
capacity units (PrtCapacityUnitTC). If this input sub-unit can
reliably sense this value, the value is sensed by the printer
and may not be changed by management requests; otherwise, the
value may be written (by a Remote Control Panel or a Management
Application). The value (-1) means other and specifically
indicates that the sub-unit places no restrictions on this
parameter. The value (-2) means unknown. The value (-3) means
that the printer knows that at least one unit remains."
::= { prtInputEntry 10 }
prtInputStatus OBJECT-TYPE
SYNTAX PrtSubUnitStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this input sub-unit."
::= { prtInputEntry 11 }
prtInputMediaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A description of the media contained in this input sub-unit;
This description is to be used by a client to format and
Localize a string for display to a human operator. This
description is not processed by the printer. It is used to
provide information not expressible in terms of the other
media attributes (e.g., prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
prtInputMediaType)."
-- The following reference was not included in RFC 1759.
REFERENCE
"The PWG Standardized Media Names specification [PWGMEDIA]
contains the recommended values for this object. See also
RFC 3805 Appendix C,'Media Names', which lists the values
Of standardized media names defined in ISO/IEC 10175."
::= { prtInputEntry 12 }
-- INPUT MEASUREMENT
--
-- _______ | |
-- ^ | |
-- | | | |
-- | |_ _ _ _ _ _ _ _| _______________ |direction
-- | | | ^ v
-- MaxCapacity | Sheets | |
-- | | left | CurrentLevel
-- | | in | |
-- v | tray | v
-- _______ +_______________+ _______
-- The Extended Input Group
prtInputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name assigned to this input sub-unit."
::= { prtInputEntry 13 }
prtInputVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name of this input sub-unit."
::= { prtInputEntry 14 }
prtInputModel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model name of this input sub-unit."
::= { prtInputEntry 15 }
prtInputVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of this input sub-unit."
::= { prtInputEntry 16 }
prtInputSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number assigned to this input sub-unit."
::= { prtInputEntry 17 }
prtInputDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A free-form text description of this input sub-unit in the
localization specified by prtGeneralCurrentLocalization."
::= { prtInputEntry 18 }
prtInputSecurity OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this input sub-unit has some security associated
with it."
::= { prtInputEntry 19 }
-- The Input Media Group
--
-- The Input Media Group supports identification of media
-- installed or available for use on a printing device.
-- Medium resources are identified by name, and include a
-- collection of characteristic attributes that may further be
-- used for selection and management of them.
-- The Input Media group consists of a set of optional
-- "columns" in the Input Table. In this manner, a minimally
-- conforming implementation may choose to not support reporting
-- of media resources if it cannot do so.
prtInputMediaWeight OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The weight of the medium associated with this input sub-unit
in grams / per meter squared. The value (-2) means unknown."
::= { prtInputEntry 20 }
prtInputMediaType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the type of medium associated with this input sub
unit. This name need not be processed by the printer; it might
simply be displayed to an operator.
NOTE: The above description has been modified from RFC 1759."
-- The following reference was not included in RFC 1759.
REFERENCE
"The PWG Standardized Media Names specification [PWGMEDIA],
section 3 Media Type Names, contains the recommended values for
this object. Implementers may add additional string values.
The naming conventions in ISO 9070 are recommended in order to
avoid potential name clashes."
::= { prtInputEntry 21 }
prtInputMediaColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the color of the medium associated with
this input sub-unit using standardized string values.
NOTE: The above description has been modified from RFC 1759."
-- The following reference was not included in RFC 1759.
REFERENCE
"The PWG Standardized Media Names specification [PWGMEDIA],
section 4 Media Color Names, contains the recommended values
for this object. Implementers may add additional string values.
The naming conventions in ISO 9070 are recommended in order to
avoid potential name clashes."
::= { prtInputEntry 22 }
prtInputMediaFormParts OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of parts associated with the medium
associated with this input sub-unit if the medium is a
multi-part form. The value (-1) means other and
specifically indicates that the device places no
restrictions on this parameter. The value (-2) means
unknown."
::= { prtInputEntry 23 }
-- The Input Switching Group
--
-- The input switching group allows the administrator to set the
-- input subunit time-out for the printer and to control the
-- automatic input subunit switching by the printer when an input
-- subunit becomes empty.
prtInputMediaLoadTimeout OBJECT-TYPE
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the printer is not able to print due to a subunit being
empty or the requested media must be manually loaded, the
printer will wait for the duration (in seconds) specified by
this object. Upon expiration of the time-out, the printer will
take the action specified by prtInputNextIndex.
The event which causes the printer to enter the waiting state
is product specific. If the printer is not waiting for manually
fed media, it may switch from an empty subunit to a different
subunit without waiting for the time-out to expire.
A value of (-1) implies 'other' or 'infinite' which translates
to 'wait forever'. The action which causes printing to continue
is product specific. A value of (-2) implies 'unknown'."
::= { prtInputEntry 24 }
prtInputNextIndex OBJECT-TYPE
SYNTAX Integer32 (-3..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInputIndex corresponding to the input subunit
which will be used when this input subunit is emptied and the
time-out specified by prtInputMediaLoadTimeout expires. A value
of zero(0) indicates that auto input switching will not occur
when this input subunit is emptied. If the time-out specified
by prtInputLoadMediaTimeout expires and this value is zero(0),
the job will be aborted. A value of (-1) means other. The
value (-2)means 'unknown' and specifically indicates that an
implementation specific method will determine the next input
subunit to use at the time this subunit is emptied and the time
out expires. The value(-3) means input switching is not
supported for this subunit."
::= { prtInputEntry 25 }
-- The Output Group
--
-- Output sub-units are managed as a tabular, indexed collection
-- of possible devices capable of receiving media delivered from
-- the printing process. Output sub-units typically have a
-- location, a type, an identifier, a set of constraints on
-- possible media sizes and potentially other characteristics,
-- and may be capable of indicating current status or capacity.
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
prtOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the devices capable of receiving media delivered
from the printing process."
::= { prtOutput 2 }
prtOutputEntry OBJECT-TYPE
SYNTAX PrtOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a device capable of receiving media delivered
from the printing process. Entries may exist in the table for
each device index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtOutputIndex }
::= { prtOutputTable 1 }
PrtOutputEntry ::= SEQUENCE {
prtOutputIndex Integer32,
prtOutputType PrtOutputTypeTC,
prtOutputCapacityUnit PrtCapacityUnitTC,
prtOutputMaxCapacity Integer32,
prtOutputRemainingCapacity Integer32,
prtOutputStatus PrtSubUnitStatusTC,
prtOutputName OCTET STRING,
prtOutputVendorName OCTET STRING,
prtOutputModel OCTET STRING,
prtOutputVersion OCTET STRING,
prtOutputSerialNumber OCTET STRING,
prtOutputDescription PrtLocalizedDescriptionStringTC,
prtOutputSecurity PresentOnOff,
prtOutputDimUnit PrtMediaUnitTC,
prtOutputMaxDimFeedDir Integer32,
prtOutputMaxDimXFeedDir Integer32,
prtOutputMinDimFeedDir Integer32,
prtOutputMinDimXFeedDir Integer32,
prtOutputStackingOrder PrtOutputStackingOrderTC,
prtOutputPageDeliveryOrientation
PrtOutputPageDeliveryOrientationTC,
prtOutputBursting PresentOnOff,
prtOutputDecollating PresentOnOff,
prtOutputPageCollated PresentOnOff,
prtOutputOffsetStacking PresentOnOff
}
prtOutputIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by this printer to identify this output
sub-unit. Although these values may change due to a major
reconfiguration of the sub-unit (e.g., the addition of new
output devices to the printer), values SHOULD remain stable
across successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtOutputEntry 1 }
prtOutputType OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
-- by this object.
SYNTAX PrtOutputTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of technology supported by this output sub-unit."
::= { prtOutputEntry 2 }
prtOutputCapacityUnit OBJECT-TYPE
SYNTAX PrtCapacityUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this output sub-unit."
::= { prtOutputEntry 3 }
prtOutputMaxCapacity OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of this output sub-unit in output sub-
unit capacity units (PrtCapacityUnitTC). There is no convention
associated with the media itself so this value essentially
reflects claimed capacity. If this output sub-unit can reliably
sense this value, the value is sensed by the printer and may
not be changed by management requests; otherwise, the value may
be written (by a Remote Control Panel or a Management
Application). The value (-1) means other and specifically
indicates that the sub-unit places no restrictions on this
parameter. The value (-2) means unknown."
::= { prtOutputEntry 4 }
prtOutputRemainingCapacity OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-3..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units
(PrtCapacityUnitTC)of this output sub-unit. If this output sub-
unit can reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by a Remote Control Panel
or a Management Application). The value (-1) means other and
specifically indicates that the sub-unit places no restrictions
on this parameter. The value (-2) means unknown. The value
(-3) means that the printer knows that there remains capacity
for at least one unit."
::= { prtOutputEntry 5 }
prtOutputStatus OBJECT-TYPE
SYNTAX PrtSubUnitStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this output sub-unit."
::= { prtOutputEntry 6 }
-- OUTPUT MEASUREMENT
--
-- _______ | | ________
-- ^ | | ^
-- | | | |
-- | | |RemainingCapacity
-- MaxCapacity| | |
-- | | | v ^
-- | |_ _ _ _ _ _ _ _ | _______________ |direction
-- | | Sheets | |
-- | | in |
-- v | Output |
-- _______ +________________+
-- The Extended Output Group
prtOutputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name assigned to this output sub-unit."
::= { prtOutputEntry 7 }
prtOutputVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name of this output sub-unit."
::= { prtOutputEntry 8 }
prtOutputModel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model name assigned to this output sub-unit.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtOutputEntry 9 }
prtOutputVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of this output sub-unit."
::= { prtOutputEntry 10 }
prtOutputSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number assigned to this output sub-unit."
::= { prtOutputEntry 11 }
prtOutputDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A free-form text description of this output sub-unit in the
localization specified by prtGeneralCurrentLocalization."
::= { prtOutputEntry 12 }
prtOutputSecurity OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this output sub-unit has some security associated
with it and if that security is enabled or not."
::= { prtOutputEntry 13 }
-- The Output Dimensions Group
prtOutputDimUnit OBJECT-TYPE
SYNTAX PrtMediaUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
dimensional values for this output sub-unit."
::= { prtOutputEntry 14 }
prtOutputMaxDimFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum dimensions supported by this output sub-unit
for measurements taken parallel relative to the feed
direction associated with that sub-unit in output
sub-unit dimensional units (controlled by prtOutputDimUnit,
which uses PrtMediaUnitTC). If this output sub-unit can
reliably sense this value, the value is sensed by the printer
and may not be changed with management protocol operations.
The value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification and to explain the purpose of (-1) and (-2)."
::= { prtOutputEntry 15 }
prtOutputMaxDimXFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum dimensions supported by this output sub-unit
for measurements taken ninety degrees relative to the
feed direction associated with that sub-unit in output
sub-unit dimensional units (controlled by prtOutputDimUnit,
which uses PrtMediaUnitTC). If this output sub-unit can
reliably sense this value, the value is sensed by the printer
and may not be changed with management protocol operations.
The value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification and to explain the purpose of (-1) and (-2)."
::= { prtOutputEntry 16 }
prtOutputMinDimFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum dimensions supported by this output sub-unit
for measurements taken parallel relative to the feed
direction associated with that sub-unit in output
sub-unit dimensional units (controlled by prtOutputDimUnit,
which uses PrtMediaUnitTC). If this output sub-unit can
reliably sense this value, the value is sensed by the printer
and may not be changed with management protocol operations.
The value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification and to explain the purpose of (-1) and (-2)."
::= { prtOutputEntry 17 }
prtOutputMinDimXFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum dimensions supported by this output sub-unit
for measurements taken ninety degrees relative to the
feed direction associated with that sub-unit in output
sub-unit dimensional units (controlled by prtOutputDimUnit,
which uses PrtMediaUnitTC). If this output sub-unit can
reliably sense this value, the value is sensed by the printer
and may not be changed with management protocol operations.
The value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification and to explain the purpose of (-1) and (-2)."
::= { prtOutputEntry 18 }
-- The Output Features Group
prtOutputStackingOrder OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtOutputStackingOrderTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current state of the stacking order for the
associated output sub-unit. 'FirstToLast' means
that as pages are output the front of the next page is
placed against the back of the previous page.
'LasttoFirst' means that as pages are output the back
of the next page is placed against the front of the
previous page."
::= { prtOutputEntry 19 }
prtOutputPageDeliveryOrientation OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtOutputPageDeliveryOrientationTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The reading surface that will be 'up' when pages are
delivered to the associated output sub-unit. Values are
faceUp and faceDown. (Note: interpretation of these
values is in general context-dependent based on locale;
presentation of these values to an end-user should be
normalized to the expectations of the user)."
::= { prtOutputEntry 20 }
prtOutputBursting OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the outputting sub-unit supports
bursting, and if so, whether the feature is enabled. Bursting
is the process by which continuous media is separated into
individual sheets, typically by bursting along pre-formed
perforations."
::= { prtOutputEntry 21 }
prtOutputDecollating OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output supports decollating,
and if so, whether the feature is enabled. Decollating is the
process by which the individual parts within a multi-part form
are separated and sorted into separate stacks for each part."
::= { prtOutputEntry 22 }
prtOutputPageCollated OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output sub-unit supports page
collation, and if so, whether the feature is enabled. See RFC
3805 Appendix A, Glossary Of Terms, for definition of how this
document defines collation.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtOutputEntry 23 }
prtOutputOffsetStacking OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output supports offset
stacking,and if so, whether the feature is enabled. See RFC
3805 Appendix A, Glossary Of Terms, for how Offset Stacking is
defined by this document.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtOutputEntry 24 }
-- The Marker Group
--
-- A marker is the mechanism that produces marks on the print
-- media. The marker sub-units and their associated supplies are
-- represented by the Marker Group in the model. A printer can
-- contain one or more marking mechanisms. Some examples of
-- multiple marker sub-units are: a printer
-- with separate markers for normal and magnetic ink or an
-- imagesetter that can output to both a proofing device and
-- final film. Each marking device can have its own set of
-- characteristics associated with it, such as marking technology
-- and resolution.
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
-- The printable area margins as listed below define an area of
-- the print media which is guaranteed to be printable for all
-- combinations of input, media paths, and interpreters for this
-- marker.
prtMarkerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The marker table provides a description of each marker
sub-unit contained within the printer.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarker 2 }
prtMarkerEntry OBJECT-TYPE
SYNTAX PrtMarkerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries in this table define the characteristics and status
of each marker sub-unit in the printer.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtMarkerIndex }
::= { prtMarkerTable 1 }
PrtMarkerEntry ::= SEQUENCE {
prtMarkerIndex Integer32,
prtMarkerMarkTech PrtMarkerMarkTechTC,
prtMarkerCounterUnit PrtMarkerCounterUnitTC,
prtMarkerLifeCount Counter32,
prtMarkerPowerOnCount Counter32,
prtMarkerProcessColorants Integer32,
prtMarkerSpotColorants Integer32,
prtMarkerAddressabilityUnit PrtMarkerAddressabilityUnitTC,
prtMarkerAddressabilityFeedDir Integer32,
prtMarkerAddressabilityXFeedDir Integer32,
prtMarkerNorthMargin Integer32,
prtMarkerSouthMargin Integer32,
prtMarkerWestMargin Integer32,
prtMarkerEastMargin Integer32,
prtMarkerStatus PrtSubUnitStatusTC
}
prtMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this marking
SubUnit. Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new marking
sub-units to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 1 }
prtMarkerMarkTech OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerMarkTechTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of marking technology used for this marking
sub-unit."
::= { prtMarkerEntry 2 }
prtMarkerCounterUnit OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerCounterUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit that will be used by the printer when reporting
counter values for this marking sub-unit. The time units of
measure are provided for a device like a strip recorder that
does not or cannot track the physical dimensions of the media
and does not use characters, lines or sheets."
::= { prtMarkerEntry 3 }
prtMarkerLifeCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of units of measure counted during the
life of printer using units of measure as specified by
prtMarkerCounterUnit.
Note: This object should be implemented as a persistent object
with a reliable value throughout the lifetime of the printer."
::= { prtMarkerEntry 4 }
prtMarkerPowerOnCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of units of measure counted since the
equipment was most recently powered on using units of measure
as specified by prtMarkerCounterUnit."
::= { prtMarkerEntry 5 }
prtMarkerProcessColorants OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of process colors supported by this marker. A
process color of 1 implies monochrome. The value of this
object and prtMarkerSpotColorants cannot both be 0. The value
of prtMarkerProcessColorants must be 0 or greater.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 6 }
prtMarkerSpotColorants OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of spot colors supported by this marker. The value
of this object and prtMarkerProcessColorants cannot both be 0.
Must be 0 or greater.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 7 }
prtMarkerAddressabilityUnit OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerAddressabilityUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measure of distances, as applied to the marker's
resolution.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 8 }
prtMarkerAddressabilityFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of addressable marking positions in the
feed direction per 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
or 'infinite' while a value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 9 }
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of addressable marking positions in the
cross feed direction in 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
or 'infinite' while a value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerEntry 10 }
prtMarkerNorthMargin OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin, in units identified by prtMarkerAddressabilityUnit,
from the leading edge of the medium as the medium flows through
the marking engine with the side to be imaged facing the
observer. The leading edge is the North edge and the other
edges are defined by the normal compass layout of directions
with the compass facing the observer. Printing within the area
bounded by all four margins is guaranteed for all interpreters.
The value (-2) means unknown."
::= { prtMarkerEntry 11 }
prtMarkerSouthMargin OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the South edge (see prtMarkerNorthMargin) of
the medium in units identified by prtMarkerAddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means unknown."
::= { prtMarkerEntry 12 }
prtMarkerWestMargin OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the West edge (see prtMarkerNorthMargin) of
the medium in units identified by prtMarkerAddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means unknown."
::= { prtMarkerEntry 13 }
prtMarkerEastMargin OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the East edge (see prtMarkerNorthMargin) of
the medium in units identified by prtMarkerAddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means unknown."
::= { prtMarkerEntry 14 }
prtMarkerStatus OBJECT-TYPE
SYNTAX PrtSubUnitStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this marker sub-unit."
::= { prtMarkerEntry 15 }
-- The Marker Supplies Group
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
prtMarkerSuppliesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the marker supplies available on this printer."
::= { prtMarkerSupplies 1 }
prtMarkerSuppliesEntry OBJECT-TYPE
SYNTAX PrtMarkerSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a marker supply. Entries may exist in the table
for each device index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtMarkerSuppliesIndex }
::= { prtMarkerSuppliesTable 1 }
PrtMarkerSuppliesEntry ::= SEQUENCE {
prtMarkerSuppliesIndex Integer32,
prtMarkerSuppliesMarkerIndex Integer32,
prtMarkerSuppliesColorantIndex Integer32,
prtMarkerSuppliesClass PrtMarkerSuppliesClassTC,
prtMarkerSuppliesType PrtMarkerSuppliesTypeTC,
prtMarkerSuppliesDescription PrtLocalizedDescriptionStringTC,
prtMarkerSuppliesSupplyUnit PrtMarkerSuppliesSupplyUnitTC,
prtMarkerSuppliesMaxCapacity Integer32,
prtMarkerSuppliesLevel Integer32
}
prtMarkerSuppliesIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this marker
supply. Although these values may change due to a major
supplies to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerSuppliesEntry 1 }
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the marking sub
unit with which this marker supply sub-unit is associated."
::= { prtMarkerSuppliesEntry 2 }
prtMarkerSuppliesColorantIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerColorantIndex corresponding to the
colorant with which this marker supply sub-unit is associated.
This value shall be 0 if there is no colorant table or if this
supply does not depend on a single specified colorant.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerSuppliesEntry 3 }
prtMarkerSuppliesClass OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerSuppliesClassTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this supply entity represents a supply that
is consumed or a receptacle that is filled.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerSuppliesEntry 4 }
prtMarkerSuppliesType OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerSuppliesTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of this supply."
::= { prtMarkerSuppliesEntry 5 }
prtMarkerSuppliesDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this supply container/receptacle in the
localization specified by prtGeneralCurrentLocalization."
::= { prtMarkerSuppliesEntry 6 }
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerSuppliesSupplyUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit of measure of this marker supply container/receptacle.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerSuppliesEntry 7 }
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of this supply container/receptacle
expressed in prtMarkerSuppliesSupplyUnit. If this supply
container/receptacle can reliably sense this value, the value
is reported by the printer and is read-only; otherwise, the
value may be written (by a Remote Control Panel or a Management
Application). The value (-1) means other and specifically
indicates that the sub-unit places no restrictions on this
parameter. The value (-2) means unknown."
::= { prtMarkerSuppliesEntry 8 }
prtMarkerSuppliesLevel OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-3..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current level if this supply is a container; the remaining
space if this supply is a receptacle. If this supply
container/receptacle can reliably sense this value, the value
is reported by the printer and is read-only; otherwise, the
value may be written (by a Remote Control Panel or a Management
Application). The value (-1) means other and specifically
indicates that the sub-unit places no restrictions on this
parameter. The value (-2) means unknown. A value of (-3) means
that the printer knows that there is some supply/remaining
space, respectively."
::= { prtMarkerSuppliesEntry 9 }
-- The Marker Colorant Group
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
prtMarkerColorantTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerColorantEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all of the colorants available on the printer."
::= { prtMarkerColorant 1 }
prtMarkerColorantEntry OBJECT-TYPE
SYNTAX PrtMarkerColorantEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a colorant available on the printer. Entries may
exist in the table for each device index with a device type of
'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtMarkerColorantIndex }
::= { prtMarkerColorantTable 1 }
PrtMarkerColorantEntry ::= SEQUENCE {
prtMarkerColorantIndex Integer32,
prtMarkerColorantMarkerIndex Integer32,
prtMarkerColorantRole PrtMarkerColorantRoleTC,
prtMarkerColorantValue OCTET STRING,
prtMarkerColorantTonality Integer32
}
prtMarkerColorantIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this colorant.
Although these values may change due to a major reconfiguration
of the device (e.g., the addition of new colorants to the
printer) , values SHOULD remain stable across successive
printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMarkerColorantEntry 1 }
prtMarkerColorantMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the marker sub
unit with which this colorant entry is associated."
::= { prtMarkerColorantEntry 2 }
prtMarkerColorantRole OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMarkerColorantRoleTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The role played by this colorant."
::= { prtMarkerColorantEntry 3 }
prtMarkerColorantValue OBJECT-TYPE
-- NOTE: The string length range has been increased from RFC 1759.
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the color of this colorant using standardized
string names from ISO 10175 (DPA) and ISO 10180 (SPDL) such as:
other
unknown
white
red
green
blue
cyan
magenta
yellow
black
Implementers may add additional string values. The naming
conventions in ISO 9070 are recommended in order to avoid
potential name clashes"
::= { prtMarkerColorantEntry 4 }
prtMarkerColorantTonality OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distinct levels of tonality realizable by a marking sub
unit when using this colorant. This value does not include the
number of levels of tonal difference that an interpreter can
obtain by techniques such as half toning. This value must be at
least 2."
::= { prtMarkerColorantEntry 5 }
-- The Media Path Group
--
-- The media paths encompass the mechanisms in the printer that
-- move the media through the printer and connect all other media
-- related sub-units: inputs, outputs, markers and finishers. A
-- printer contains one or more media paths. These are
-- represented by the Media Path Group in the model.
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
prtMediaPathTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMediaPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The media path table includes both physical and logical paths
within the printer.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPath 4 }
prtMediaPathEntry OBJECT-TYPE
SYNTAX PrtMediaPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device index with a
device type of 'printer' Each entry defines the physical
characteristics of and the status of the media path. The data
provided indicates the maximum throughput and the media
size limitations of these subunits.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtMediaPathIndex }
::= { prtMediaPathTable 1 }
PrtMediaPathEntry ::= SEQUENCE {
prtMediaPathIndex Integer32,
prtMediaPathMaxSpeedPrintUnit PrtMediaPathMaxSpeedPrintUnitTC,
prtMediaPathMediaSizeUnit PrtMediaUnitTC,
prtMediaPathMaxSpeed Integer32,
prtMediaPathMaxMediaFeedDir Integer32,
prtMediaPathMaxMediaXFeedDir Integer32,
prtMediaPathMinMediaFeedDir Integer32,
prtMediaPathMinMediaXFeedDir Integer32,
prtMediaPathType PrtMediaPathTypeTC,
prtMediaPathDescription PrtLocalizedDescriptionStringTC,
prtMediaPathStatus PrtSubUnitStatusTC
}
prtMediaPathIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this media
path. Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new media
paths to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPathEntry 1 }
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMediaPathMaxSpeedPrintUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measure used in specifying the speed of all media
paths in the printer."
::= { prtMediaPathEntry 2 }
prtMediaPathMediaSizeUnit OBJECT-TYPE
SYNTAX PrtMediaUnitTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The units of measure of media size for use in calculating and
relaying dimensional values for all media paths in the
printer."
::= { prtMediaPathEntry 3 }
prtMediaPathMaxSpeed OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum printing speed of this media path expressed in
prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'."
::= { prtMediaPathEntry 4 }
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum physical media size in the feed direction of this
media path expressed in units of measure specified by
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited'
a value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPathEntry 5 }
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum physical media size across the feed direction of
this media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPathEntry 6 }
prtMediaPathMinMediaFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum physical media size in the feed direction of this
media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPathEntry 7 }
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum physical media size across the feed direction of
this media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtMediaPathEntry 8 }
prtMediaPathType OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtMediaPathTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the media path for this media path."
::= { prtMediaPathEntry 9 }
prtMediaPathDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturer-provided description of this media path in
the localization specified by prtGeneralCurrentLocalization."
::= { prtMediaPathEntry 10 }
prtMediaPathStatus OBJECT-TYPE
SYNTAX PrtSubUnitStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this media path."
::= { prtMediaPathEntry 11 }
-- The Print Job Delivery Channel Group
--
-- Print Job Delivery Channels are independent sources of print
-- data. Here, print data is the term used for the information
-- that is used to construct printed pages and may have both data
-- and control aspects. The output of a channel is in a form
-- suitable for input to one of the interpreters as a
-- stream. A channel may be independently enabled (allowing
-- print data to flow) or disabled (stopping the flow of
-- print data). A printer may have one or more channels.
--
-- The Print Job Delivery Channel table describes the
-- capabilities of the printer and not what is currently being
-- performed by the printer
--
-- Basically, the print job delivery channel abstraction
-- describes the final processing step of getting the print data
-- to an interpreter. It might include some level of
-- decompression or decoding of print stream data.
-- channel. All of these aspects are hidden in the channel
-- abstraction.
--
-- There are many kinds of print job delivery channels; some of
-- which are based on networks and others which are not. For
-- example, a channel can be a serial (or parallel) connection;
-- it can be a service, such as the UNIX Line Printer Daemon
-- (LPD), offering services over a network connection; or
-- it could be a disk drive into which a floppy disk with
-- the print data is inserted. Each print job delivery channel is
-- identified by the electronic path and/or service protocol
-- used to deliver print data to a print data interpreter.
--
-- Channel example Implementation
--
-- serial port channel bi-directional data channel
-- parallel port channel often uni-directional channel
-- IEEE 1284 port channel bi-directional channel
-- SCSI port channel bi-directional
-- Apple PAP channel may be based on LocalTalk,
-- Ethernet or Tokentalk
-- LPD Server channel TCP/IP based, port 515
-- Netware Remote Printer SPX/IPX based channel
-- Netware Print Server SPX/IPX based channel
--
-- It is easy to note that this is a mixed bag. There are
-- some physical connections over which no (or very meager)
-- protocols are run (e.g., the serial or old parallel ports)
-- and there are services which often have elaborate
-- protocols that run over a number of protocol stacks. In
-- the end, what is important is the delivery of print data
-- through the channel.
--
-- The print job delivery channel sub-units are represented by
-- the Print Job Delivery Channel Group in the Model. It has a
-- current print job control language, which can be used to
-- specify which interpreter is to be used for the print data and
-- to query and change environment variables used by the
-- interpreters (and Management Applications). There is also a
-- default interpreter that is to be used if an interpreter is
-- not explicitly specified using the Control Language.
-- The first seven items in the Print Job Delivery Channel Table
-- define the "channel" itself. A channel typically depends on
-- other protocols and interfaces to provide the data that flows
-- through the channel.
--
-- Control of a print job delivery channel is largely limited to
-- enabling or disabling the entire channel itself. It is likely
-- that more control of the process of accessing print data
-- will be needed over time. Thus, the ChannelType will
-- allow type-specific data to be associated with each
-- channel (using ChannelType specific groups in a fashion
-- analogous to the media specific MIBs that are associated
-- with the IANAIfType in the Interfaces Table). As a first
-- step in this direction, each channel will identify the
-- underlying Interface on which it is based. This is the
-- eighth object in each row of the table.
-- The Print Job Delivery Channel Table
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
prtChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel table represents the set of input data sources
which can provide print data to one or more of the
interpreters available on a printer.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtChannel 1 }
prtChannelEntry OBJECT-TYPE
SYNTAX PrtChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device index with a
device type of 'printer'. Each channel table entry is
characterized by a unique protocol stack and/or addressing.
The channel may also have printer dependent features that are
associated with a printing language.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtChannelIndex }
::= { prtChannelTable 1 }
PrtChannelEntry ::= SEQUENCE {
prtChannelIndex Integer32,
prtChannelType PrtChannelTypeTC,
prtChannelProtocolVersion OCTET STRING,
prtChannelCurrentJobCntlLangIndex Integer32,
prtChannelDefaultPageDescLangIndex Integer32,
prtChannelState PrtChannelStateTC,
prtChannelIfIndex InterfaceIndexOrZero,
prtChannelStatus PrtSubUnitStatusTC,
prtChannelInformation OCTET STRING
}
prtChannelIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this data
channel. Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new data
channels to the printer), values SHOULD remain stable across
successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtChannelEntry 1 }
prtChannelType OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtChannelTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of this print data channel. This object provides the
linkage to ChannelType-specific groups that may (conceptually)
extend the prtChannelTable with additional details about that
channel."
::= { prtChannelEntry 2 }
prtChannelProtocolVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the protocol used on this channel. The format
used for version numbering depends on prtChannelType."
::= { prtChannelEntry 3 }
prtChannelCurrentJobCntlLangIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the Control
Language Interpreter for this channel. This interpreter defines
the syntax used for control functions, such as querying or
changing environment variables and identifying job boundaries
(e.g., PJL, PostScript, NPAP). A value of zero indicates that
there is no current Job Control Language Interpreter for this
channel.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtChannelEntry 4 }
prtChannelDefaultPageDescLangIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the Page
Description Language Interpreter for this channel. This
interpreter defines the default Page Description Language
interpreter to be used for the print data unless the Control
Language is used to select a specific interpreter (e.g., PCL,
PostScript Language, auto-sense). A value of zero indicates
that there is no default page description language interpreter
for this channel.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtChannelEntry 5 }
prtChannelState OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtChannelStateTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of this print data channel. The value determines
whether control information and print data is allowed through
this channel or not."
::= { prtChannelEntry 6 }
prtChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero -- Was Integer32 in RFC 1759.
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of ifIndex in the ifTable; see the Interfaces Group
MIB [RFC2863] which corresponds to this channel.
When more than one row of the ifTable is relevant, this is the
index of the row representing the topmost layer in the
interface hierarchy. A value of zero indicates that no
interface is associated with this channel.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtChannelEntry 7 }
prtChannelStatus OBJECT-TYPE
SYNTAX PrtSubUnitStatusTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the channel."
::= { prtChannelEntry 8 }
prtChannelInformation OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Auxiliary information to allow a printing application to use
the channel for data submission to the printer. An application
capable of using a specific PrtChannelType should be able to
use the combined information from the prtChannelInformation and
other channel and interface group objects to 'bootstrap' its
use of the channel. prtChannelInformation is not intended to
provide a general channel description, nor to provide
information that is available once the channel is in use.
The encoding and interpretation of the prtChannelInformation
object is specific to channel type. The description of each
PrtChannelType enum value for which prtChannelInformation is
defined specifies the appropriate encoding and interpretation,
including interaction with other objects. For channel types
that do not specify a prtChannelInformation value, its value
shall be null (0 length).
When a new PrtChannelType enumeration value is registered, its
accompanying description must specify the encoding and
interpretation of the prtChannelInformation value for the
channel type. prtChannelInformation semantics for an existing
PrtChannelType may be added or amended in the same manner as
described in section 2.4.1 for type 2 enumeration values.
The prtChannelInformation specifies values for a collection of
channel attributes, represented as text according to the
following rules:
1. The prtChannelInformation is not affected by localization.
2. The prtChannelInformation is a list of entries representing
items, in order:
a. A keyword, composed of alphabetic characters (A-Z, a-z)
represented by their NVT ASCII [RFC854] codes, that
identifies a channel attribute,
b. The NVT ASCII code for an Equals Sign (=) (code 61) to
delimit the keyword,
c. A data value encoded using rules specific to the
PrtChannelType to with the prtChannelInformation applies which
must in no case allow an octet with value 10 (the NVT ASCII
Line Feed code),
d. the NVT ASCII code for a Line Feed character (code 10) to
delimit the data value.
No other octets shall be present.
Keywords are case-sensitive. Conventionally, keywords are
capitalized (including each word of a multi-word keyword) and
since they occupy space in the prtChannelInformation, they are
kept short.
3. If a channel attribute has multiple values, it is
represented by multiple entries with the same keyword, each
specifying one value. Otherwise, there shall be at most one
entry for each attribute.
4. By default, entries may appear in any order. If there are
ordering constraints for particular entries, these must be
specified in their definitions.
5. The prtChannelInformation value by default consists of text
represented by NVT ASCII graphics character codes. However,
other representations may be specified:
a. In cases where the prtChannelInformation value contains
information not normally coded in textual form, whatever
symbolic representation is conventionally used for the
information should be used for encoding the
prtChannelInformation value. (For instance, a binary port value
might be represented as a decimal number using NVT ASCII
codes.) Such encoding must be specified in the definition of
the value.
b. The value may contain textual information in a character set
other than NVT ASCII graphics characters. (For instance, an
identifier might consist of ISO 10646 text encoded using the
UTF-8 encoding scheme.) Such a character set and its encoding
must be specified in the definition of the value.
6. For each PrtChannelType for which prtChannelInformation
entries are defined, the descriptive text associated with the
PrtChannelType enumeration value shall specify the following
information for each entry:
Title: Brief description phrase, e.g.: 'Port name',
'Service Name', etc.
Keyword: The keyword value, e.g.: 'Port' or 'Service'
Syntax: The encoding of the entry value if it cannot be
directly represented by NVT ASCII.
Status: 'Mandatory', 'Optional', or 'Conditionally
Mandatory'
Multiplicity: 'Single' or 'Multiple' to indicate whether the
entry may be present multiple times.
Description: Description of the use of the entry, other
information required to complete the definition
(e.g.: ordering constraints, interactions between
entries).
Applications that interpret prtChannelInformation should ignore
unrecognized entries, so they are not affected if new entry
types are added."
::= { prtChannelEntry 9 }
-- The Interpreter Group
--
-- The interpreter sub-units are responsible for the conversion
-- of a description of intended print instances into images that
-- are to be marked on the media. A printer may have one or more
-- interpreters. The interpreter sub-units are represented by the
-- Interpreter Group in the Model. Each interpreter is generally
-- implemented with software running on the System Controller
-- sub-unit. The Interpreter Table has one entry per interpreter
-- where the interpreters include both Page Description Language
-- (PDL) Interpreters and Control Language Interpreters.
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
-- Interpreter Table
prtInterpreterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInterpreterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interpreter table is a table representing the
interpreters in the printer. An entry shall be placed in the
interpreter table for each interpreter on the printer.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInterpreter 1 }
prtInterpreterEntry OBJECT-TYPE
SYNTAX PrtInterpreterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device index with a
device type of 'printer'. Each table entry provides a complete
description of the interpreter, including version information,
rendering resolutions, default character sets, output
orientation, and communication capabilities.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtInterpreterIndex }
::= { prtInterpreterTable 1 }
PrtInterpreterEntry ::= SEQUENCE {
prtInterpreterIndex Integer32,
prtInterpreterLangFamily PrtInterpreterLangFamilyTC,
prtInterpreterLangLevel OCTET STRING,
prtInterpreterLangVersion OCTET STRING,
prtInterpreterDescription PrtLocalizedDescriptionStringTC,
prtInterpreterVersion OCTET STRING,
prtInterpreterDefaultOrientation PrtPrintOrientationTC,
prtInterpreterFeedAddressability Integer32,
prtInterpreterXFeedAddressability Integer32,
prtInterpreterDefaultCharSetIn IANACharset,
prtInterpreterDefaultCharSetOut IANACharset,
prtInterpreterTwoWay PrtInterpreterTwoWayTC
}
prtInterpreterIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each PDL or control language for which
there exists an interpreter or emulator in the printer. The
value is used to identify this interpreter. Although these
values may change due to a major reconfiguration of the device
(e.g., the addition of new interpreters to the printer), values
SHOULD remain stable across successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInterpreterEntry 1 }
prtInterpreterLangFamily OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtInterpreterLangFamilyTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The family name of a Page Description Language (PDL) or
control language which this interpreter in the printer can
interpret or emulate.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInterpreterEntry 2 }
prtInterpreterLangLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of the language which this interpreter is
interpreting or emulating. This might contain a value like
'5e'for an interpreter which is emulating level 5e of the PCL
language. It might contain '2' for an interpreter which is
emulating level 2 of the PostScript language. Similarly it
might contain '2' for an interpreter which is emulating level 2
of the HPGL language."
::= { prtInterpreterEntry 3 }
prtInterpreterLangVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date code or version of the language which this
interpreter is interpreting or emulating."
::= { prtInterpreterEntry 4 }
prtInterpreterDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string to identify this interpreter in the localization
specified by prtGeneralCurrentLocalization as opposed to the
language which is being interpreted. It is anticipated that
this string will allow manufacturers to unambiguously identify
their interpreters."
::= { prtInterpreterEntry 5 }
prtInterpreterVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date code, version number, or other product specific
information tied to this interpreter. This value is associated
with the interpreter, rather than with the version of the
language which is being interpreted or emulated."
::= { prtInterpreterEntry 6 }
prtInterpreterDefaultOrientation OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtPrintOrientationTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current orientation default for this interpreter. This
value may be overridden for a particular job (e.g., by a
command in the input data stream)."
::= { prtInterpreterEntry 7 }
prtInterpreterFeedAddressability OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnits (as specified
by prtMarkerDefaultIndex) for this interpreter. The
value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInterpreterEntry 8 }
prtInterpreterXFeedAddressability OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum interpreter addressability in the cross feed
direction in 10000 prtMarkerAddressabilityUnits (as specified
by prtMarkerDefaultIndex) for this interpreter. The
value (-1) means other and specifically indicates that the
sub-unit places no restrictions on this parameter. The value
(-2) means unknown.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtInterpreterEntry 9 }
prtInterpreterDefaultCharSetIn OBJECT-TYPE
SYNTAX IANACharset
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default coded character set for input octets encountered
outside a context in which the Page Description Language
established the interpretation of the octets. (Input octets are
presented to the interpreter through a path defined in the
channel group.)"
::= { prtInterpreterEntry 10 }
prtInterpreterDefaultCharSetOut OBJECT-TYPE
SYNTAX IANACharset
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default character set for data coming from this
interpreter through the printer's output channel (i.e. the
'backchannel')."
::= { prtInterpreterEntry 11 }
prtInterpreterTwoWay OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtInterpreterTwoWayTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not this interpreter returns information
back to the host."
::= { prtInterpreterEntry 12 }
-- The Console Group
--
-- Many printers have a console on the printer, the operator
-- console, that is used to display and modify the state of the
-- printer. The console can be as simple as a few indicators and
-- switches or as complicated as full screen displays and
-- keyboards. There can be at most one such console.
-- The Display Buffer Table
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
prtConsoleDisplayBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtConsoleDisplayBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Physical display buffer for printer console display or
operator panel
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleDisplayBuffer 5 }
prtConsoleDisplayBufferEntry OBJECT-TYPE
SYNTAX PrtConsoleDisplayBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one entry for each physical line on
the display. Lines cannot be added or deleted. Entries may
exist in the table for each device index with a device type of
'printer'.
for clarification."
INDEX { hrDeviceIndex, prtConsoleDisplayBufferIndex }
::= { prtConsoleDisplayBufferTable 1 }
PrtConsoleDisplayBufferEntry ::= SEQUENCE {
prtConsoleDisplayBufferIndex Integer32,
prtConsoleDisplayBufferText PrtConsoleDescriptionStringTC
}
prtConsoleDisplayBufferIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each console line in the printer. The value
is used to identify this console line. Although these values
may change due to a major reconfiguration of the device (e.g.,
the addition of new console lines to the printer). Values
SHOULD remain stable across successive printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleDisplayBufferEntry 1 }
prtConsoleDisplayBufferText OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtConsoleDescriptionStringTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The content of a line in the logical display buffer of
the operator's console of the printer. When a write
operation occurs, normally a critical message, to one of
the LineText strings, the agent should make that line
displayable if a physical display is present. Writing a zero
length string clears the line. It is an implementation-
specific matter as to whether the agent allows a line to be
overwritten before it has been cleared. Printer generated
strings shall be in the localization specified by
prtConsoleLocalization.Management Application generated strings
should be localized by the Management Application."
::= { prtConsoleDisplayBufferEntry 2 }
-- The Console Light Table
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
prtConsoleLightTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtConsoleLightEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The console light table provides a description and state
information for each light present on the printer console.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleLights 6 }
prtConsoleLightEntry OBJECT-TYPE
SYNTAX PrtConsoleLightEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device index with a
device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtConsoleLightIndex }
::= { prtConsoleLightTable 1 }
PrtConsoleLightEntry ::= SEQUENCE {
prtConsoleLightIndex Integer32,
prtConsoleOnTime Integer32,
prtConsoleOffTime Integer32,
prtConsoleColor PrtConsoleColorTC,
prtConsoleDescription PrtConsoleDescriptionStringTC
}
prtConsoleLightIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535) -- Lower limit invalid in RFC 1759
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this light.
Although these values may change due to a major
reconfiguration of the device (e.g., the addition of new lights
to the printer). Values SHOULD remain stable across successive
printer power cycles.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleLightEntry 1 }
prtConsoleOnTime OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, in conjunction with prtConsoleOffTime, defines
the current status of the light. If both prtConsoleOnTime and
prtConsoleOffTime are non-zero, the lamp is blinking and the
values presented define the on time and off time, respectively,
in milliseconds. If prtConsoleOnTime is zero and
prtConsoleOffTime is non-zero, the lamp is off. If
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the
lamp is on. If both values are zero the lamp is off.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleLightEntry 2 }
prtConsoleOffTime OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, in conjunction with prtConsoleOnTime, defines the
current status of the light. If both prtConsoleOnTime and
prtConsoleOffTime are non-zero, the lamp is blinking and the
values presented define the on time and off time, respectively,
in milliseconds. If prtConsoleOnTime is zero and
prtConsoleOffTime is non-zero, the lamp is off. If
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the
lamp is on. If both values are zero the lamp is off.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtConsoleLightEntry 3 }
prtConsoleColor OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtConsoleColorTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The color of this light."
::= { prtConsoleLightEntry 4 }
prtConsoleDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtConsoleDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor description or label of this light in the
localization specified by prtConsoleLocalization."
::= { prtConsoleLightEntry 5 }
-- The Alerts Group
--
-- The table contains information on the severity, component,
-- detail location within the component, alert code and
-- description of each critical alert that is currently active
-- within the printer. See 2.2.13 for a more complete
-- description of the alerts table and its management.
--
-- Each parameter in the Trap PDU is a full OID which itself is
-- indexed by the host resources MIB "hrDeviceIndex" object. In
-- order for a management station to obtain the correct
-- "hrDeviceIndex" associated with a particular Trap PDU, the
-- "hrDeviceIndex" value can be extracted from the returned OID
-- value in the Trap PDU when the PDU is received by the
-- Management station.
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
prtAlertTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The prtAlertTable lists all the critical and non-critical
alerts currently active in the printer. A critical alert is
one that stops the printer from printing immediately and
printing can not continue until the critical alert condition
is eliminated. Non-critical alerts are those items that do
not stop printing but may at some future time.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlert 1 }
prtAlertEntry OBJECT-TYPE
SYNTAX PrtAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index with a device type of 'printer'.
NOTE: The above description has been modified from RFC 1759
for clarification."
INDEX { hrDeviceIndex, prtAlertIndex }
::= { prtAlertTable 1 }
PrtAlertEntry ::= SEQUENCE {
prtAlertIndex Integer32,
prtAlertSeverityLevel PrtAlertSeverityLevelTC,
prtAlertTrainingLevel PrtAlertTrainingLevelTC,
prtAlertGroup PrtAlertGroupTC,
prtAlertGroupIndex Integer32,
prtAlertLocation Integer32,
prtAlertCode PrtAlertCodeTC,
prtAlertDescription PrtLocalizedDescriptionStringTC,
prtAlertTime TimeTicks
}
prtAlertIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined. The MAX-ACCESS has
-- been changed from not accessible to allow the object to be
-- included (as originally in RFC 1759) in the trap bindings.
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index value used to determine which alerts have been added
or removed from the alert table. This is an incrementing
integer initialized to 1 when the printer is reset. (i.e., The
first event placed in the alert table after a reset of the
printer shall have an index value of 1.) When the printer adds
an alert to the table, that alert is assigned the next higher
integer value from the last item entered into the table. If
the index value reaches its maximum value, the next index value
used must be 1.
NOTE: The management application will read the alert table when
a trap or event notification occurs or at a periodic rate and
then parse the table to determine if any new entries were added
by comparing the last known index value with the current
highest index value. The management application will then
update its copy of the alert table. When the printer discovers
that an alert is no longer active, the printer shall remove the
row for that alert from the table and shall reduce the number
of rows in the table. The printer may add or delete any number
of rows from the table at any time. The management station can
detect when binary change alerts have been deleted by
requesting an attribute of each alert, and noting alerts as
deleted when that retrieval is not possible. The objects
'prtAlertCriticalEvents'and 'prtAlertAllEvents' in the
'prtGeneralTable' reduce the need for management applications
to scan the 'prtAlertTable'.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlertEntry 1 }
prtAlertSeverityLevel OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtAlertSeverityLevelTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry into the
table."
::= { prtAlertEntry 2 }
prtAlertTrainingLevel OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtAlertTrainingLevelTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See TEXTUAL-CONVENTION PrtAlertTrainingLevelTC.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlertEntry 3 }
prtAlertGroup OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtAlertGroupTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of printer
model groups, i.e., examples of types of sub-units. Wherever
possible, these enumerations match the sub-identifier that
identifies the relevant table in the printmib."
::= { prtAlertEntry 4 }
prtAlertGroupIndex OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The low-order index of the row within the table identified
by prtAlertGroup that represents the sub-unit of the printer
that caused this alert, or -1 if not applicable. The
combination of the prtAlertGroup and the prtAlertGroupIndex
defines exactly which printer sub-unit caused the alert; for
example, Input #3, Output#2, and Marker #1. Every object in
this MIB is indexed with hrDeviceIndex and optionally, another
index variable. If this other index variable is present in the
table that generated the alert, it will be used as the value
for this object. Otherwise, this value shall be -1.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlertEntry 5 }
prtAlertLocation OBJECT-TYPE
-- NOTE: In RFC 1759, the range was not defined.
SYNTAX Integer32 (-2..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for example,
there is an alert in Input #2 at location number 7. The value
(-2) indicates unknown.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlertEntry 6 }
prtAlertCode OBJECT-TYPE
-- NOTE: In RFC 1759, the enumeration values were implicitly
-- defined by this object.
SYNTAX PrtAlertCodeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See associated TEXTUAL-CONVENTION PrtAlertCodeTC.
NOTE: The above description has been modified from RFC 1759
for clarification."
::= { prtAlertEntry 7 }
prtAlertDescription OBJECT-TYPE
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
-- to a TC to better support localization of the object.
SYNTAX PrtLocalizedDescriptionStringTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of this alert entry in the localization
specified by prtGeneralCurrentLocalization. The description is
provided by the printer to further elaborate on the enumerated
alert or provide information in the case where the code is
classified as 'other' or 'unknown'. The printer is required to
return a description string but the string may be a null
string."
::= { prtAlertEntry 8 }
prtAlertTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time that this alert was
generated."
::= { prtAlertEntry 9 }
printerV1Alert OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The value of the enterprise-specific OID in an SNMPv1 trap
sent signaling a critical event in the prtAlertTable."
::= { prtAlert 2 }
printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 }
printerV2Alert NOTIFICATION-TYPE
OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
STATUS current
DESCRIPTION
"This trap is sent whenever a critical event is added to the
prtAlertTable.
NOTE: The prtAlertIndex object was redundantly included in the
bindings of the 'printerV2Alert' notification in RFC 1759, even
though the value exists in the instance qualifier of all the
other bindings. This object has been retained to provide
compatiblity with existing RFC 1759 implementaions."
::= { printerV2AlertPrefix 1 }
-- Note that the SNMPv2 to SNMPv1 translation rules dictate that
-- the preceding structure will result in SNMPv1 traps of the
-- following form:
--
-- printerAlert TRAP-TYPE
-- ENTERPRISE printerV1Alert
-- VARIABLES { prtAlertIndex, prtAlertSeverityLevel,
-- prtAlertGroup, prtAlertGroupIndex,
-- prtAlertLocation, prtAlertCode }
-- DESCRIPTION
-- "This trap is sent whenever a critical event is added
-- to the prtAlertTable."
-- ::= 1
-- Conformance Information
prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 }
-- compliance statements
prtMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for agents that implement the
printer MIB as defined by RFC 1759."
MODULE -- this module
MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup,
prtOutputGroup,
prtMarkerGroup, prtMediaPathGroup,
prtChannelGroup, prtInterpreterGroup,
prtConsoleGroup, prtAlertTableGroup }
OBJECT prtGeneralReset
SYNTAX INTEGER {
notResetting(3),
resetToNVRAM(5)
}
DESCRIPTION
"It is conformant to implement just these two states in this
object. Any additional states are optional."
OBJECT prtConsoleOnTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleOffTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
::= { prtMIBConformance 1 }
prtMIB2Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for agents that implement the
printer MIB V2."
-- The changes from RFC 1759 fall into 2 categories:
-- 1. New objects plus existing objects with a MIN-ACCESS of
-- read-only are included. Existing objects have been added
-- to this category due to feedback from implementers and
-- interoperability testing. This allows products to be
-- be designed with a higher degree of SNMP security.
-- 2. New object groups have been added to include all new
-- objects in this MIB. All new object groups are optional.
-- Any MIB that is compliant with RFC 1759 will also be
-- compliant with this version of the MIB.
MODULE -- this module
MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup,
prtOutputGroup,
prtMarkerGroup, prtMediaPathGroup,
prtChannelGroup, prtInterpreterGroup,
prtConsoleGroup, prtAlertTableGroup }
OBJECT prtGeneralReset
SYNTAX INTEGER {
notResetting(3),
resetToNVRAM(5)
}
DESCRIPTION
"It is conformant to implement just these two states in this
object. Any additional states are optional."
OBJECT prtGeneralCurrentLocalization
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtGeneralCurrentOperator
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtGeneralServicePerson
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtGeneralPrinterName
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtGeneralSerialNumber
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputDefaultIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaDimFeedDirDeclared
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMaxCapacity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputCurrentLevel
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaName
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputName
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputSecurity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaWeight
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaType
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaColor
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaFormParts
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputDefaultIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputMaxCapacity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputRemainingCapacity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputName
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputSecurity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputMaxDimFeedDir
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputMaxDimXFeedDir
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputMinDimFeedDir
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputMinDimXFeedDir
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputStackingOrder
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputPageDeliveryOrientation
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputBursting
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputDecollating
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputPageCollated
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtOutputOffsetStacking
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtMarkerDefaultIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtMarkerSuppliesMaxCapacity
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtMarkerSuppliesLevel
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtMediaPathDefaultIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtChannelCurrentJobCntlLangIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtChannelDefaultPageDescLangIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtChannelState
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtChannelIfIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInterpreterDefaultOrientation
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInterpreterDefaultCharSetIn
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInterpreterDefaultCharSetOut
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleLocalization
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleDisable
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleDisplayBufferText
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleOnTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtConsoleOffTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtAlertIndex
MIN-ACCESS accessible-for-notify
DESCRIPTION
"It is conformant to implement this object as
accessible-for-notify "
GROUP prtResponsiblePartyGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtExtendedInputGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtInputMediaGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtExtendedOutputGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtOutputDimensionsGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtOutputFeaturesGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtMarkerSuppliesGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtMarkerColorantGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtAlertTimeGroup
DESCRIPTION
"This group is unconditionally optional."
-- the prtResponsiblePartyGroup, prtExtendedInputGroup,
-- prtInputMediaGroup, prtExtendedOutputGroup,
-- prtOutputDimensionsGroup, prtOutputFeaturesGroup,
-- prtMarkerSuppliesGroup, prtMarkerColorantGroup, and the
-- prtAlertTimeGroup are completely optional. However, it is
-- strongly RECOMMENDED that the prtAlertTimeGroup be implemented.
-- New to version 2 of this printer MIB:
OBJECT prtAuxiliarySheetStartupPage
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtAuxiliarySheetBannerPage
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputMediaLoadTimeout
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
OBJECT prtInputNextIndex
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only"
GROUP prtAuxiliarySheetGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtInputSwitchingGroup
DESCRIPTION
"This group is unconditionally optional."
GROUP prtGeneralV2Group
DESCRIPTION
"This group is unconditionally optional."
GROUP prtAlertTableV2Group
DESCRIPTION
"This group is unconditionally optional."
GROUP prtChannelV2Group
DESCRIPTION
"This group is unconditionally optional."
GROUP prtAlertTrapGroup
DESCRIPTION
"This group is unconditionally optional."
::= { prtMIBConformance 3 }
prtMIBGroups OBJECT IDENTIFIER ::= { prtMIBConformance 2 }
-- These groups are from RFC 1759 and are applicable to Printer MIB V2
prtGeneralGroup OBJECT-GROUP
OBJECTS { prtGeneralConfigChanges,
prtGeneralCurrentLocalization,
prtGeneralReset, prtCoverDescription,
prtCoverStatus,
prtLocalizationLanguage, prtLocalizationCountry,
prtLocalizationCharacterSet, prtStorageRefIndex,
prtDeviceRefIndex }
STATUS current
DESCRIPTION
"The general printer group."
::= { prtMIBGroups 1 }
prtResponsiblePartyGroup OBJECT-GROUP
OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson }
STATUS current
DESCRIPTION
"The responsible party group contains contact information for
humans responsible for the printer."
::= { prtMIBGroups 2 }
prtInputGroup OBJECT-GROUP
OBJECTS { prtInputDefaultIndex, prtInputType, prtInputDimUnit,
prtInputMediaDimFeedDirDeclared,
prtInputMediaDimXFeedDirDeclared,
prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputCapacityUnit,
prtInputMaxCapacity, prtInputCurrentLevel, prtInputStatus,
prtInputMediaName }
STATUS current
DESCRIPTION
"The input group."
::= { prtMIBGroups 3 }
prtExtendedInputGroup OBJECT-GROUP
OBJECTS { prtInputName, prtInputVendorName, prtInputModel,
prtInputVersion, prtInputSerialNumber,
prtInputDescription, prtInputSecurity }
STATUS current
DESCRIPTION
"The extended input group."
::= { prtMIBGroups 4 }
prtInputMediaGroup OBJECT-GROUP
OBJECTS { prtInputMediaWeight, prtInputMediaType,
prtInputMediaColor, prtInputMediaFormParts }
STATUS current
DESCRIPTION
"The input media group."
::= { prtMIBGroups 5 }
prtOutputGroup OBJECT-GROUP
OBJECTS { prtOutputDefaultIndex, prtOutputType,
prtOutputCapacityUnit, prtOutputMaxCapacity,
prtOutputRemainingCapacity, prtOutputStatus }
STATUS current
DESCRIPTION
"The output group."
::= { prtMIBGroups 6 }
prtExtendedOutputGroup OBJECT-GROUP
OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel,
prtOutputVersion, prtOutputSerialNumber,
prtOutputDescription, prtOutputSecurity }
STATUS current
DESCRIPTION
"The extended output group."
::= { prtMIBGroups 7 }
prtOutputDimensionsGroup OBJECT-GROUP
OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir,
prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir,
prtOutputMinDimXFeedDir }
STATUS current
DESCRIPTION
"The output dimensions group"
::= { prtMIBGroups 8 }
prtOutputFeaturesGroup OBJECT-GROUP
OBJECTS { prtOutputStackingOrder,
prtOutputPageDeliveryOrientation, prtOutputBursting,
prtOutputDecollating, prtOutputPageCollated,
prtOutputOffsetStacking }
STATUS current
DESCRIPTION
"The output features group."
::= { prtMIBGroups 9 }
prtMarkerGroup OBJECT-GROUP
OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech,
prtMarkerCounterUnit, prtMarkerLifeCount,
prtMarkerPowerOnCount, prtMarkerProcessColorants,
prtMarkerSpotColorants, prtMarkerAddressabilityUnit,
prtMarkerAddressabilityFeedDir,
prtMarkerAddressabilityXFeedDir, prtMarkerNorthMargin,
prtMarkerSouthMargin, prtMarkerWestMargin,
prtMarkerEastMargin, prtMarkerStatus }
STATUS current
DESCRIPTION
"The marker group."
::= { prtMIBGroups 10 }
prtMarkerSuppliesGroup OBJECT-GROUP
OBJECTS { prtMarkerSuppliesMarkerIndex,
prtMarkerSuppliesColorantIndex, prtMarkerSuppliesClass,
prtMarkerSuppliesType, prtMarkerSuppliesDescription,
prtMarkerSuppliesSupplyUnit,
prtMarkerSuppliesMaxCapacity, prtMarkerSuppliesLevel }
STATUS current
DESCRIPTION
"The marker supplies group."
::= { prtMIBGroups 11 }
prtMarkerColorantGroup OBJECT-GROUP
OBJECTS { prtMarkerColorantMarkerIndex, prtMarkerColorantRole,
prtMarkerColorantValue, prtMarkerColorantTonality }
STATUS current
DESCRIPTION
"The marker colorant group."
::= { prtMIBGroups 12 }
prtMediaPathGroup OBJECT-GROUP
OBJECTS { prtMediaPathDefaultIndex, prtMediaPathMaxSpeedPrintUnit,
prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed,
prtMediaPathMaxMediaFeedDir,
prtMediaPathMaxMediaXFeedDir,
prtMediaPathMinMediaFeedDir,
prtMediaPathMinMediaXFeedDir, prtMediaPathType,
prtMediaPathDescription, prtMediaPathStatus}
STATUS current
DESCRIPTION
"The media path group."
::= { prtMIBGroups 13 }
prtChannelGroup OBJECT-GROUP
OBJECTS { prtChannelType, prtChannelProtocolVersion,
prtChannelCurrentJobCntlLangIndex,
prtChannelDefaultPageDescLangIndex, prtChannelState,
prtChannelIfIndex, prtChannelStatus
}
STATUS current
DESCRIPTION
"The channel group."
::= { prtMIBGroups 14 }
prtInterpreterGroup OBJECT-GROUP
OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel,
prtInterpreterLangVersion, prtInterpreterDescription,
prtInterpreterVersion, prtInterpreterDefaultOrientation,
prtInterpreterFeedAddressability,
prtInterpreterXFeedAddressability,
prtInterpreterDefaultCharSetIn,
prtInterpreterDefaultCharSetOut, prtInterpreterTwoWay }
STATUS current
DESCRIPTION
"The interpreter group."
::= { prtMIBGroups 15 }
prtConsoleGroup OBJECT-GROUP
OBJECTS { prtConsoleLocalization, prtConsoleNumberOfDisplayLines,
prtConsoleNumberOfDisplayChars, prtConsoleDisable,
prtConsoleDisplayBufferText, prtConsoleOnTime,
prtConsoleOffTime, prtConsoleColor,
prtConsoleDescription }
STATUS current
DESCRIPTION
"The console group."
::= { prtMIBGroups 16 }
prtAlertTableGroup OBJECT-GROUP
OBJECTS { prtAlertSeverityLevel, prtAlertTrainingLevel,
prtAlertGroup, prtAlertGroupIndex, prtAlertLocation,
prtAlertCode, prtAlertDescription }
STATUS current
DESCRIPTION
"The alert table group."
::= { prtMIBGroups 17 }
prtAlertTimeGroup OBJECT-GROUP
OBJECTS { prtAlertTime }
STATUS current
DESCRIPTION
"The alert time group. Implementation of prtAlertTime is
strongly RECOMMENDED."
::= { prtMIBGroups 18 }
prtMIB2Groups OBJECT IDENTIFIER ::= { prtMIBConformance 4 }
-- These groups are unique to Printer MIB V2
prtAuxiliarySheetGroup OBJECT-GROUP
OBJECTS { prtAuxiliarySheetStartupPage,
prtAuxiliarySheetBannerPage }
STATUS current
DESCRIPTION
"The auxiliary sheet group."
::= { prtMIBGroups 19 }
prtInputSwitchingGroup OBJECT-GROUP
OBJECTS { prtInputMediaLoadTimeout, prtInputNextIndex }
STATUS current
DESCRIPTION
"The input switching group."
::= { prtMIBGroups 20 }
prtGeneralV2Group OBJECT-GROUP
OBJECTS { prtGeneralPrinterName, prtGeneralSerialNumber }
STATUS current
DESCRIPTION
"The general printer group with new v2 objects."
::= { prtMIBGroups 21 }
prtAlertTableV2Group OBJECT-GROUP
OBJECTS { prtAlertIndex, prtAlertCriticalEvents, prtAlertAllEvents }
STATUS current
DESCRIPTION
"The alert table group with new v2 objects and prtAlertIndex
changed to MAX-ACCESS of 'read-only' for inclusion in the trap
bindings (as originally defined in RFC 1759)."
::= { prtMIBGroups 22 }
prtChannelV2Group OBJECT-GROUP
OBJECTS { prtChannelInformation }
STATUS current
DESCRIPTION
"The channel group with a new v2 object."
::= { prtMIBGroups 23 }
prtAlertTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS { printerV2Alert }
STATUS current
DESCRIPTION
"The alert trap group."
::= { prtMIBGroups 24 }
END