ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
adIdentity
FROM ADTRAN-MIB
adGenAOSConformance, adGenAOSCommon
FROM ADTRAN-AOS;
adGenAOSOverTempProtectionMib MODULE-IDENTITY
LAST-UPDATED "201411041615Z"
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
" Technical Support Dept.
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"The MIB module defines over-temperature configuration information and traps for AdtranOS products."
REVISION "201411041615Z" -- November 4, 2014 / YYYYMMDDHHMMZ
DESCRIPTION
"Created the adGenAosOverTempProtection MIB. Revision R11.6"
::= { adIdentity 10000 53 1 10 }
adGenAOSOverTempProtection OBJECT IDENTIFIER ::= { adGenAOSCommon 10 }
adGenAOSOverTempProtectionTrap OBJECT IDENTIFIER ::= { adGenAOSOverTempProtection 0 }
adGenAOSOverTempProtectionWarning NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"An over-temperature warning trap signifies that the warning temperature threshold has been exceeded."
::= { adGenAOSOverTempProtectionTrap 1 }
adGenAOSOverTempProtectionShutdown NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"An over-temperature shutdown trap signifies that the shutdown temperature threshold has been exceeded, and the unit will restart into low-power mode."
::= { adGenAOSOverTempProtectionTrap 2 }
------------------------------------------------------------
-- Conformance information
--
adGenAOSOverTempProtectionConformance OBJECT IDENTIFIER
::= { adGenAOSConformance 19}
adGenAOSOverTempProtectionGroups OBJECT IDENTIFIER
::= { adGenAOSOverTempProtectionConformance 1 }
adGenAOSOverTempProtectionCompliances OBJECT IDENTIFIER
::= { adGenAOSOverTempProtectionConformance 2 }
-- Compliance statements
--
-- Full compliance statement
adGenAOSOverTempProtectionFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement
version 2 of the adGenAosOverTempProtection MIB. When the implementation of this MIB
supports adGenAOSOverTempProtectionNotificationGroup, then such an implementation can claim
full compliance."
MODULE -- this module
GROUP adGenAOSOverTempProtectionNotificationGroup
DESCRIPTION
"This optional group defines the asynchronous
notifications generated by over-temperature protection events."
::= { adGenAOSOverTempProtectionCompliances 1 }
adGenAOSOverTempProtectionNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { adGenAOSOverTempProtectionWarning, adGenAOSOverTempProtectionShutdown }
STATUS current
DESCRIPTION
"Traps which may be used to enhance event driven
management of the chassis's over-temperature protection subsystem."
::= { adGenAOSOverTempProtectionGroups 1 }
END