mibs/MIBS/alteonos/ALTEON-TS-PHYSICAL-MIB

2311 lines
61 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- COPYRIGHT NOTICE
-- Copyright (c) Alteon WebSystems, Inc. 2001
-- All rights reserved
--
-- HISTORY
-- $Log: tigonPhysical.mib,v $
-- Revision 1.1.1.1 2004/11/01 16:55:42 maxbaker
-- initial import
--
-- Revision ge_rrekha/7 2001/11/08 19:29:40 rrekha
-- Added MIB objects vlanCurCfgStg/vlanNewCfgStg.
--
-- Revision ge_rrekha/5 2001/11/07 00:28:10 rrekha
-- Removed the range on agPortCurCfgBwmContract/agPortNewCfgBwmContract
-- and vlanCurCfgBwmContract/vlanNewCfgBwmContract since the size
-- of the table can vary. This range should be obtained from the
-- the max table size.
--
-- Revision ge_rrekha/3 2001/10/18 18:06:43 rrekha
-- Marked the old port mirroring MIBs as obsolete since they are
-- no longer supported.
--
-- Revision test_smiao/13 2001/10/12 02:42:04 smiao
-- Added LinkTrap and broadcast pkt stats for port.
--
-- Revision test_smiao/11 2001/10/11 23:54:41 smiao
-- Added physical interface info/stats in port table.
--
-- Revision test_smiao/9 2001/09/18 18:08:02 smiao
-- Implemented VLAN bit map for spanning tree group.
--
-- Revision test_smiao/7 2001/08/31 18:14:15 smiao
-- Implemented add/remove vlans for spanning tree groups.
--
-- Revision test_smiao/5 2001/07/13 23:06:27 smiao
-- Initial checked in for multiple spanning tree in SNMP and webUI.
--
-- Revision genie_rekha/10 2001/07/12 19:29:11 rekha
-- SNMP support for port-based and vlan-based port mirroring.
--
-- Revision genie_rekha/8 2001/05/29 22:54:39 rekha
-- Removed 'other' from most of the enumerations.
--
-- Revision test_smiao/3 2001/05/09 22:39:23 smiao
-- Added operational command for port mirroring in webUI and SNMP.
--
-- Revision work_rmundhra/7 2001/03/06 23:09:26 rmundhra
-- Removed Mib entry agCurCfgPortLinkTrap
-- and agNewCfgPortLinkTrap as we can configure via
-- ifLinkUpDownTrapEnable defined in rfc1573.mib.
--
-- Revision work_rmundhra/4 2001/03/01 17:16:43 rmundhra
-- Added SNMP support for configuring LinkTrap enabled/disabled.
--
-- Revision genie_rekha/5 2001/02/16 00:12:49 rekha
-- Fixed 10218: Added MIB object for port mirroring timeout.
--
-- Revision genie_rekha/2 2001/02/08 18:18:03 rekha
-- As part of the code cleanup split the Tigon MIB into smaller
-- modules. Instead of altswitch.mib these 5 new modules should be
-- used.
--
-- $EndLog$
--
-- Version 10.0.x
--
ALTEON-TS-PHYSICAL-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, Gauge, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
PhysAddress, DisplayString
FROM RFC1213-MIB
switch
FROM ALTEON-ROOT-MIB
stats, information, agent, operCmds
FROM ALTEON-TIGON-SWITCH-MIB;
vlans OBJECT IDENTIFIER ::= { switch 4 }
portmirroring OBJECT IDENTIFIER ::= { switch 6 }
trunkgroup OBJECT IDENTIFIER ::= { switch 7 }
spannTreeGrpCfg OBJECT IDENTIFIER ::= { switch 19 }
agPortConfig OBJECT IDENTIFIER ::= { agent 3 }
mirroring OBJECT IDENTIFIER ::= { switch 18 }
mirrPortMirr OBJECT IDENTIFIER ::= { mirroring 1 }
mirrVlanMirr OBJECT IDENTIFIER ::= { mirroring 2 }
portCpuStats OBJECT IDENTIFIER ::= { stats 17 }
port-stats OBJECT IDENTIFIER ::= { stats 26 }
port-info OBJECT IDENTIFIER ::= { information 1 }
-- Agent Port Table
agPortTableMaxEnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of rows in the port configuration host table."
::= { agPortConfig 1 }
agPortCurCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgPortCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of port configuration in the current_configuration block."
::= { agPortConfig 2 }
agPortCurCfgTableEntry OBJECT-TYPE
SYNTAX AgPortCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port table in the current_configuration block."
INDEX { agPortCurCfgIndx }
::= { agPortCurCfgTable 1 }
AgPortCurCfgTableEntry ::= SEQUENCE {
agPortCurCfgIndx INTEGER,
agPortCurCfgPrefLink INTEGER,
agPortCurCfgBackLink INTEGER,
agPortCurCfgState INTEGER,
agPortCurCfgVlanTag INTEGER,
agPortCurCfgStp INTEGER,
agPortCurCfgRmon INTEGER,
agPortCurCfgPVID INTEGER,
agPortCurCfgFastEthAutoNeg INTEGER,
agPortCurCfgFastEthSpeed INTEGER,
agPortCurCfgFastEthMode INTEGER,
agPortCurCfgFastEthFctl INTEGER,
agPortCurCfgGigEthAutoNeg INTEGER,
agPortCurCfgGigEthFctl INTEGER,
agPortCurCfgPortName DisplayString,
agPortCurCfgBwmContract INTEGER,
agPortCurCfgDiscardNonIPs INTEGER,
agPortCurCfgLinkTrap INTEGER
}
agPortCurCfgIndx OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the row in port configurations table."
::= { agPortCurCfgTableEntry 1 }
agPortCurCfgPrefLink OBJECT-TYPE
SYNTAX INTEGER {
fast-ethernet(2),
gigabit-ethernet(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the preferred link."
::= { agPortCurCfgTableEntry 2 }
agPortCurCfgBackLink OBJECT-TYPE
SYNTAX INTEGER {
fast-ethernet(2),
gigabit-ethernet(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the backup link."
::= { agPortCurCfgTableEntry 3 }
agPortCurCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the state of the port."
::= { agPortCurCfgTableEntry 4 }
agPortCurCfgVlanTag OBJECT-TYPE
SYNTAX INTEGER {
tagged(2),
untagged(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is VLAN tag state of the port"
::= { agPortCurCfgTableEntry 5 }
agPortCurCfgStp OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to turn Spanning Tree on or off for the port."
::= { agPortCurCfgTableEntry 6 }
agPortCurCfgRmon OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to turn RMON on or off on the port."
::= { agPortCurCfgTableEntry 7 }
agPortCurCfgPVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default VLAN ID for the port."
::= { agPortCurCfgTableEntry 8 }
agPortCurCfgFastEthAutoNeg OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to turn the autonegotiation on or off
for fast Ethernet connection."
::= { agPortCurCfgTableEntry 9 }
agPortCurCfgFastEthSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbs10(2),
mbs100(3),
mbs10or100(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Selects the port speed for fast Ethernet connection."
::= { agPortCurCfgTableEntry 10 }
agPortCurCfgFastEthMode OBJECT-TYPE
SYNTAX INTEGER {
full-duplex(2),
half-duplex(3),
full-or-half-duplex(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to select port mode for fast Ethernet connection."
::= { agPortCurCfgTableEntry 11 }
agPortCurCfgFastEthFctl OBJECT-TYPE
SYNTAX INTEGER {
transmit(2),
receive(3),
both(4),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Selects the port flow control for fast Ethernet connection."
::= { agPortCurCfgTableEntry 12 }
agPortCurCfgGigEthAutoNeg OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to turn the autonegotiation on or off
for gigabit Ethernet connection."
::= { agPortCurCfgTableEntry 13 }
agPortCurCfgGigEthFctl OBJECT-TYPE
SYNTAX INTEGER {
transmit(2),
receive(3),
both(4),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to select port flow control for
gigabit Ethernet connection."
::= { agPortCurCfgTableEntry 14 }
agPortCurCfgPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The switch port name."
::= { agPortCurCfgTableEntry 15 }
agPortCurCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The switch port Bandwidth Management contract number."
::= { agPortCurCfgTableEntry 16 }
agPortCurCfgDiscardNonIPs OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or disable to discard all non-IP traffic on the switch port."
::= { agPortCurCfgTableEntry 17 }
agPortCurCfgLinkTrap OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether linkUp/linkDown traps should be
generated for this interface.
By default, this object should have the value
enabled(1) for interfaces which do not operate on
'top' of any other interface (as defined in the
ifStackTable), and disabled(2) otherwise."
::= { agPortCurCfgTableEntry 18 }
agPortNewCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgPortNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of port configuration in the new_configuration block."
::= { agPortConfig 3 }
agPortNewCfgTableEntry OBJECT-TYPE
SYNTAX AgPortNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port configuration table in the new_configuration block."
INDEX { agPortNewCfgIndx }
::= { agPortNewCfgTable 1 }
AgPortNewCfgTableEntry ::= SEQUENCE {
agPortNewCfgIndx INTEGER,
agPortNewCfgPrefLink INTEGER,
agPortNewCfgBackLink INTEGER,
agPortNewCfgState INTEGER,
agPortNewCfgVlanTag INTEGER,
agPortNewCfgStp INTEGER,
agPortNewCfgRmon INTEGER,
agPortNewCfgPVID INTEGER,
agPortNewCfgFastEthAutoNeg INTEGER,
agPortNewCfgFastEthSpeed INTEGER,
agPortNewCfgFastEthMode INTEGER,
agPortNewCfgFastEthFctl INTEGER,
agPortNewCfgGigEthAutoNeg INTEGER,
agPortNewCfgGigEthFctl INTEGER,
agPortNewCfgPortName DisplayString,
agPortNewCfgBwmContract INTEGER,
agPortNewCfgDiscardNonIPs INTEGER,
agPortNewCfgLinkTrap INTEGER
}
agPortNewCfgIndx OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the row in port configurations table."
::= { agPortNewCfgTableEntry 1 }
agPortNewCfgPrefLink OBJECT-TYPE
SYNTAX INTEGER {
fast-ethernet(2),
gigabit-ethernet(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the preferred link."
::= { agPortNewCfgTableEntry 2 }
agPortNewCfgBackLink OBJECT-TYPE
SYNTAX INTEGER {
fast-ethernet(2),
gigabit-ethernet(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the backup link."
::= { agPortNewCfgTableEntry 3 }
agPortNewCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the state of the port."
::= { agPortNewCfgTableEntry 4 }
agPortNewCfgVlanTag OBJECT-TYPE
SYNTAX INTEGER {
tagged(2),
untagged(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is VLAN tag state of the port"
::= { agPortNewCfgTableEntry 5 }
agPortNewCfgStp OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to turn Spanning Tree on or off for the port."
::= { agPortNewCfgTableEntry 6 }
agPortNewCfgRmon OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to turn RMON on or off on the port."
::= { agPortNewCfgTableEntry 7 }
agPortNewCfgPVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default VLAN ID for the port."
::= { agPortNewCfgTableEntry 8 }
agPortNewCfgFastEthAutoNeg OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to turn the autonegotiation on or off
for fast Ethernet connection."
::= { agPortNewCfgTableEntry 9 }
agPortNewCfgFastEthSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbs10(2),
mbs100(3),
mbs10or100(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects the port speed for fast Ethernet connection."
::= { agPortNewCfgTableEntry 10 }
agPortNewCfgFastEthMode OBJECT-TYPE
SYNTAX INTEGER {
full-duplex(2),
half-duplex(3),
full-or-half-duplex(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to select port mode for fast Ethernet connection."
::= { agPortNewCfgTableEntry 11 }
agPortNewCfgFastEthFctl OBJECT-TYPE
SYNTAX INTEGER {
transmit(2),
receive(3),
both(4),
none(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects the port flow control for fast Ethernet connection."
::= { agPortNewCfgTableEntry 12 }
agPortNewCfgGigEthAutoNeg OBJECT-TYPE
SYNTAX INTEGER {
on(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to turn the autonegotiation on or off
for gigabit Ethernet connection."
::= { agPortNewCfgTableEntry 13 }
agPortNewCfgGigEthFctl OBJECT-TYPE
SYNTAX INTEGER {
transmit(2),
receive(3),
both(4),
none(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to select port flow control for
gigabit Ethernet connection."
::= { agPortNewCfgTableEntry 14 }
agPortNewCfgPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The switch port name."
::= { agPortNewCfgTableEntry 15 }
agPortNewCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The switch port Bandwidth Management contract number."
::= { agPortNewCfgTableEntry 16 }
agPortNewCfgDiscardNonIPs OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable to discard all non-IP traffic on the switch port."
::= { agPortNewCfgTableEntry 17 }
agPortNewCfgLinkTrap OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether linkUp/linkDown traps should be
generated for this interface.
By default, this object should have the value
enabled(1) for interfaces which do not operate on
'top' of any other interface (as defined in the
ifStackTable), and disabled(2) otherwise."
::= { agPortNewCfgTableEntry 18 }
-- VLAN group
vlanMaxEnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of rows in the VLAN configuration table."
::= { vlans 1 }
vlanCurCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of VLAN configuration."
::= { vlans 2 }
vlanCurCfgTableEntry OBJECT-TYPE
SYNTAX VlanCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the VLAN configuration table."
INDEX { vlanCurCfgVlanId }
::= { vlanCurCfgTable 1 }
VlanCurCfgTableEntry ::= SEQUENCE {
vlanCurCfgVlanId INTEGER,
vlanCurCfgVlanName DisplayString,
vlanCurCfgPorts OCTET STRING,
vlanCurCfgState INTEGER,
vlanCurCfgJumbo INTEGER,
vlanCurCfgBwmContract INTEGER,
vlanCurCfgStg INTEGER
}
vlanCurCfgVlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN identifier."
::= { vlanCurCfgTableEntry 1 }
vlanCurCfgVlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN name."
::= { vlanCurCfgTableEntry 2 }
vlanCurCfgPorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port list in the VLAN. The ports are presented in bitmap format.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ port 8
|| ||
|| ||___ port 7
|| |____ port 6
|| . . .
||_________ port 1
|__________ reserved
where x : 1 - The represented port belongs to the VLAN
0 - The represented port does not belong to the VLAN"
::= { vlanCurCfgTableEntry 3 }
vlanCurCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or disable a VLAN"
::= { vlanCurCfgTableEntry 4 }
vlanCurCfgJumbo OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or Disable the Jumbo frame support for the VLAN "
::= { vlanCurCfgTableEntry 5 }
vlanCurCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default contract number the VLAN "
::= { vlanCurCfgTableEntry 6 }
vlanCurCfgStg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Spanning Tree Group for the VLAN."
::= { vlanCurCfgTableEntry 7 }
vlanNewCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of VLAN configuration."
::= { vlans 3 }
vlanNewCfgTableEntry OBJECT-TYPE
SYNTAX VlanNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the VLAN configuration table."
INDEX { vlanNewCfgVlanId }
::= { vlanNewCfgTable 1 }
VlanNewCfgTableEntry ::= SEQUENCE {
vlanNewCfgVlanId INTEGER,
vlanNewCfgVlanName DisplayString,
vlanNewCfgPorts OCTET STRING,
vlanNewCfgState INTEGER,
vlanNewCfgJumbo INTEGER,
vlanNewCfgAddPort INTEGER,
vlanNewCfgRemovePort INTEGER,
vlanNewCfgDelete INTEGER,
vlanNewCfgBwmContract INTEGER,
vlanNewCfgStg INTEGER
}
vlanNewCfgVlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN identifier."
::= { vlanNewCfgTableEntry 1 }
vlanNewCfgVlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VLAN name."
::= { vlanNewCfgTableEntry 2 }
vlanNewCfgPorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port list in the VLAN. The ports are presented in bitmap format.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ port 8
|| ||
|| ||___ port 7
|| |____ port 6
|| . . .
||_________ port 1
|__________ reserved
where x : 1 - The represented port belongs to the VLAN
0 - The represented port does not belong to the VLAN"
::= { vlanNewCfgTableEntry 3 }
vlanNewCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable a VLAN"
::= { vlanNewCfgTableEntry 4 }
vlanNewCfgJumbo OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable the Jumbo frame support for the VLAN "
::= { vlanNewCfgTableEntry 5 }
vlanNewCfgAddPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port to be added to the specified VLAN. A '0' value is
returned when read."
::= { vlanNewCfgTableEntry 6 }
vlanNewCfgRemovePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port to be removed from the specified VLAN. A '0'
value is returned when read."
::= { vlanNewCfgTableEntry 7 }
vlanNewCfgDelete OBJECT-TYPE
SYNTAX INTEGER {
other(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is an action object to create or delete a VLAN.
other(1) is returned always when read.
The following values are writable: delete(2)...to delete a VLAN"
::= { vlanNewCfgTableEntry 8 }
vlanNewCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default contract number for the VLAN."
::= { vlanNewCfgTableEntry 9 }
vlanNewCfgStg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Spanning Tree Group for the VLAN."
::= { vlanNewCfgTableEntry 10 }
-- Port Mirroring Group
pmCurCfgMonitoringPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The port number of the monitoring port."
::= { portmirroring 1 }
pmNewCfgMonitoringPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS obsolete
DESCRIPTION
"The port number of the monitoring port."
::= { portmirroring 2 }
pmCurCfgMirroredPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The port number of the mirrored port."
::= { portmirroring 3 }
pmNewCfgMirroredPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS obsolete
DESCRIPTION
"The port number of the mirrored port."
::= { portmirroring 4 }
pmCurCfgMonitoredTraffic OBJECT-TYPE
SYNTAX INTEGER {
none(2),
received(3),
transmitted(4),
both(5)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The type of traffic to be monitored with respect to the mirrored
port."
::= { portmirroring 5 }
pmNewCfgMonitoredTraffic OBJECT-TYPE
SYNTAX INTEGER {
none(2),
received(3),
transmitted(4),
both(5)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION
"The type of traffic to be monitored with respect to the
mirrored port."
::= { portmirroring 6 }
pmCurCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The state of Port mirroring."
::= { portmirroring 7 }
pmNewCfgState OBJECT-TYPE
SYNTAX INTEGER {
enabled(2),
disabled(3)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION
"The state of Port mirroring."
::= { portmirroring 8 }
pmCurCfgTimeout OBJECT-TYPE
SYNTAX INTEGER (0..86400)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The mirroring timeout value in seconds."
::= { portmirroring 9 }
pmNewCfgTimeout OBJECT-TYPE
SYNTAX INTEGER (0..86400)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"The mirroring timeout value in seconds."
::= { portmirroring 10 }
-- Trunk Group Group
trunkGroupTableMaxSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of entries in trunk group table."
::= { trunkgroup 1 }
trunkGroupCurCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrunkGroupCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of trunk group configuration."
::= { trunkgroup 2 }
trunkGroupCurCfgTableEntry OBJECT-TYPE
SYNTAX TrunkGroupCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the trunk group configuration table."
INDEX { trunkGroupCurCfgIndex }
::= { trunkGroupCurCfgTable 1 }
TrunkGroupCurCfgTableEntry ::= SEQUENCE {
trunkGroupCurCfgIndex INTEGER,
trunkGroupCurCfgPorts OCTET STRING,
trunkGroupCurCfgState INTEGER,
trunkGroupCurCfgBwmContract INTEGER
}
trunkGroupCurCfgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of the trunk group."
::= { trunkGroupCurCfgTableEntry 1 }
trunkGroupCurCfgPorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port list in the trunk group. The ports are presented in
bitmap format.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ port 8
|| ||
|| ||___ port 7
|| |____ port 6
|| . . .
||_________ port 1
|__________ reserved
where x : 1 - The represented port belongs to the trunk group
0 - The represented port does not belong to the trunk group"
::= { trunkGroupCurCfgTableEntry 2 }
trunkGroupCurCfgState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or disable a trunk group."
::= { trunkGroupCurCfgTableEntry 3 }
trunkGroupCurCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default BW contract of a trunk group."
::= { trunkGroupCurCfgTableEntry 4 }
-- Trunk-Group New configuration
trunkGroupNewCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrunkGroupNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of trunk group configuration."
::= { trunkgroup 3 }
trunkGroupNewCfgTableEntry OBJECT-TYPE
SYNTAX TrunkGroupNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the trunk group configuration table."
INDEX { trunkGroupNewCfgIndex }
::= { trunkGroupNewCfgTable 1 }
TrunkGroupNewCfgTableEntry ::= SEQUENCE {
trunkGroupNewCfgIndex INTEGER,
trunkGroupNewCfgPorts OCTET STRING,
trunkGroupNewCfgAddPort INTEGER,
trunkGroupNewCfgRemovePort INTEGER,
trunkGroupNewCfgState INTEGER,
trunkGroupNewCfgDelete INTEGER,
trunkGroupNewCfgBwmContract INTEGER
}
trunkGroupNewCfgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of the trunk group."
::= { trunkGroupNewCfgTableEntry 1 }
trunkGroupNewCfgPorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port list in the trunk group. The ports are presented
in bitmap format.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ port 8
|| ||
|| ||___ port 7
|| |____ port 6
|| . . .
||_________ port 1
|__________ reserved
where x : 1 - The represented port belongs to the trunk group
0 - The represented port does not belong to the trunk group"
::= { trunkGroupNewCfgTableEntry 2 }
trunkGroupNewCfgAddPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port to be added in the trunk group. When read, 0 is returned."
::= { trunkGroupNewCfgTableEntry 3 }
trunkGroupNewCfgRemovePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port to be deleted from the trunk group. when read, 0
is returned."
::= { trunkGroupNewCfgTableEntry 4 }
trunkGroupNewCfgState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable a trunk group."
::= { trunkGroupNewCfgTableEntry 5 }
trunkGroupNewCfgDelete OBJECT-TYPE
SYNTAX INTEGER {
other(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the value to delete(2) will delete the entire
row. When read, other(1) is returned."
::= { trunkGroupNewCfgTableEntry 6 }
trunkGroupNewCfgBwmContract OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default BW contract of a trunk group."
::= { trunkGroupNewCfgTableEntry 7 }
--
-- Spanning Tree Group Configuration
--
-- This group specifies the additional configurations that are not
-- covered by the Bridge MIB (RFC 1493).
-- The relative Spanning Tree information can be retrieved or configured
-- using Bridge MIB with an unique community string for each group specified
-- in entLogicalTable of Entity MIB (RFC 2037).
--
stgCurCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF StgCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of Spanning Tree Groups configuration in the current_config."
::= { spannTreeGrpCfg 1 }
stgCurCfgTableEntry OBJECT-TYPE
SYNTAX StgCurCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular Spanning Tree Group configuration."
INDEX { stgCurCfgIndex }
::= { stgCurCfgTable 1 }
StgCurCfgTableEntry ::= SEQUENCE {
stgCurCfgIndex INTEGER,
stgCurCfgState INTEGER,
stgCurCfgVlanBmap1 OCTET STRING,
stgCurCfgVlanBmap2 OCTET STRING
}
stgCurCfgIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of a particular Spanning Tree Group. This is also
index to the entLogicalTable of Entity MIB."
::= { stgCurCfgTableEntry 1 }
stgCurCfgState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Turn on of off Spanning Tree operation of a particular Spanning
Tree Group."
::= { stgCurCfgTableEntry 2 }
stgCurCfgVlanBmap1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vlans applied to the spanning tree group. The vlans are
presented in bitmap format. This string displays vlan number
from 1 to 2048.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ vlan 9
|| ||
|| ||___ vlan 8
|| |____ vlan 7
|| . . .
||_________ vlan 2
|__________ vlan 1 (as index to stgCurCfgTable)
where x : 1 - The represented vlan applied to the spanning tree.
0 - The represented vlan not applied to the spanning tree"
::= { stgCurCfgTableEntry 3 }
stgCurCfgVlanBmap2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vlans applied to the spanning tree group. The vlans are
presented in bitmap format. This string displays vlan number
from 2049 to 4096.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ vlan 2057
|| ||
|| ||___ vlan 2056
|| |____ vlan 2055
|| . . .
||_________ vlan 2050
|__________ vlan 2049 (as index to stgCurCfgTable)
where x : 1 - The represented vlan applied to the spanning tree.
0 - The represented vlan not applied to the spanning tree"
::= { stgCurCfgTableEntry 4 }
stgNewCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF StgNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of Spanning Tree Groups configuration in the new_config."
::= { spannTreeGrpCfg 2 }
stgNewCfgTableEntry OBJECT-TYPE
SYNTAX StgNewCfgTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular Spanning Tree Group configuration."
INDEX { stgNewCfgIndex }
::= { stgNewCfgTable 1 }
StgNewCfgTableEntry ::= SEQUENCE {
stgNewCfgIndex INTEGER,
stgNewCfgState INTEGER,
stgNewCfgDefaultCfg INTEGER,
stgNewCfgAddVlan INTEGER,
stgNewCfgRemoveVlan INTEGER,
stgNewCfgVlanBmap1 OCTET STRING,
stgNewCfgVlanBmap2 OCTET STRING
}
stgNewCfgIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of a particular Spanning Tree Group. This is also
index to the entLogicalTable of Entity MIB."
::= { stgNewCfgTableEntry 1 }
stgNewCfgState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turn on of off Spanning Tree operation of a particular Spanning
Tree Group."
::= { stgNewCfgTableEntry 2 }
stgNewCfgDefaultCfg OBJECT-TYPE
SYNTAX INTEGER {
default-config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the value to default-config(1) will set the default
configuration as recommended by IEEE 802.1D for a particular
Spanning Tree Group. default-config (1) is always returned
When read, but it does not mean anything."
::= { stgNewCfgTableEntry 3 }
stgNewCfgAddVlan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The vlan to be added to the specified Spanning Tree Group. A
'0' value is returned when read."
::= {stgNewCfgTableEntry 4 }
stgNewCfgRemoveVlan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The vlan to be removed from the specified Spanning Tree Group.
A '0' value is returned when read."
::= { stgNewCfgTableEntry 5 }
stgNewCfgVlanBmap1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vlans applied to the spanning tree group. The vlans are
presented in bitmap format. This string displays vlan number
from 1 to 2048.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ vlan 9
|| ||
|| ||___ vlan 8
|| |____ vlan 7
|| . . .
||_________ vlan 2
|__________ vlan 1 (as index to stgCurCfgTable)
where x : 1 - The represented vlan applied to the spanning tree.
0 - The represented vlan not applied to the spanning tree"
::= { stgNewCfgTableEntry 6 }
stgNewCfgVlanBmap2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vlans applied to the spanning tree group. The vlans are
presented in bitmap format. This string displays vlan number
from 2049 to 4096.
in receiving order:
OCTET 1 OCTET 2 .....
xxxxxxxx xxxxxxxx .....
|| || |_ vlan 2057
|| ||
|| ||___ vlan 2056
|| |____ vlan 2055
|| . . .
||_________ vlan 2050
|__________ vlan 2049 (as index to stgCurCfgTable)
where x : 1 - The represented vlan applied to the spanning tree.
0 - The represented vlan not applied to the spanning tree"
::= { stgNewCfgTableEntry 7 }
stgCurCfgPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF StgCurCfgPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of Spanning Tree Group port configuration in the
current_config."
::= { spannTreeGrpCfg 3 }
stgCurCfgPortTableEntry OBJECT-TYPE
SYNTAX StgCurCfgPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about port configuration of a particular Spanning Tree
Group."
INDEX { stgCurCfgStgIndex, stgCurCfgPortIndex }
::= { stgCurCfgPortTable 1 }
StgCurCfgPortTableEntry ::= SEQUENCE {
stgCurCfgStgIndex INTEGER,
stgCurCfgPortIndex INTEGER,
stgCurCfgPortState INTEGER
}
stgCurCfgStgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of a particular Spanning Tree Group. This is also
index to the entLogicalTable of Entity MIB."
::= { stgCurCfgPortTableEntry 1 }
stgCurCfgPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port identifier of a particular Spanning Tree Group."
::= { stgCurCfgPortTableEntry 2 }
stgCurCfgPortState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Turn on of off Spanning Tree operation of a particular port of a
Spanning Tree Group."
::= { stgCurCfgPortTableEntry 3 }
stgNewCfgPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF StgNewCfgPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of Spanning Tree Group port configuration in the
new_config."
::= { spannTreeGrpCfg 4 }
stgNewCfgPortTableEntry OBJECT-TYPE
SYNTAX StgNewCfgPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about port configuration of a particular Spanning Tree
Group."
INDEX { stgNewCfgStgIndex, stgNewCfgPortIndex }
::= { stgNewCfgPortTable 1 }
StgNewCfgPortTableEntry ::= SEQUENCE {
stgNewCfgStgIndex INTEGER,
stgNewCfgPortIndex INTEGER,
stgNewCfgPortState INTEGER
}
stgNewCfgStgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identifier of a particular Spanning Tree Group. This is also
index to the entLogicalTable of Entity MIB."
::= { stgNewCfgPortTableEntry 1 }
stgNewCfgPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port identifier of a particular Spanning Tree Group."
::= { stgNewCfgPortTableEntry 2 }
stgNewCfgPortState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turn on of off Spanning Tree operation of a particular port of a
Spanning Tree Group."
::= { stgNewCfgPortTableEntry 3 }
-- Complete Port Mirroring
-- Port-based port mirroring
pmCurCfgPortMirrState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of port-based port mirroring."
::= { mirrPortMirr 1 }
pmNewCfgPortMirrState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The state of port-based port mirroring."
::= { mirrPortMirr 2 }
pmCurCfgPortMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmCurCfgPortMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of monitoring ports."
::= { mirrPortMirr 3 }
pmCurCfgPortMonitorEntry OBJECT-TYPE
SYNTAX PmCurCfgPortMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the monitoring port table."
INDEX { pmCurCfgPmirrMoniPortIndex, pmCurCfgPmirrMirrPortIndex }
::= { pmCurCfgPortMonitorTable 1 }
PmCurCfgPortMonitorEntry ::= SEQUENCE {
pmCurCfgPmirrMoniPortIndex INTEGER,
pmCurCfgPmirrMirrPortIndex INTEGER,
pmCurCfgPmirrDirection INTEGER
}
pmCurCfgPmirrMoniPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The monitoring port number."
::= { pmCurCfgPortMonitorEntry 1 }
pmCurCfgPmirrMirrPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mirrored port number"
::= { pmCurCfgPortMonitorEntry 2 }
pmCurCfgPmirrDirection OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2),
both(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of traffic to be monitored with respect to the
mirrored port."
::= { pmCurCfgPortMonitorEntry 3 }
pmNewCfgPortMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmNewCfgPortMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of monitoring ports."
::= { mirrPortMirr 4 }
pmNewCfgPortMonitorEntry OBJECT-TYPE
SYNTAX PmNewCfgPortMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the monitoring port table."
INDEX { pmNewCfgPmirrMoniPortIndex, pmNewCfgPmirrMirrPortIndex }
::= { pmNewCfgPortMonitorTable 1 }
PmNewCfgPortMonitorEntry ::= SEQUENCE {
pmNewCfgPmirrMoniPortIndex INTEGER,
pmNewCfgPmirrMirrPortIndex INTEGER,
pmNewCfgPmirrDirection INTEGER,
pmNewCfgPmirrDelete INTEGER
}
pmNewCfgPmirrMoniPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The monitoring port number."
::= { pmNewCfgPortMonitorEntry 1 }
pmNewCfgPmirrMirrPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mirrored port number"
::= { pmNewCfgPortMonitorEntry 2 }
pmNewCfgPmirrDirection OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2),
both(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of traffic to be monitored with respect to the
mirrored port."
::= { pmNewCfgPortMonitorEntry 3 }
pmNewCfgPmirrDelete OBJECT-TYPE
SYNTAX INTEGER {
other(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the value to delete(2) will delete the entire
row. When read, other(1) is returned."
::= { pmNewCfgPortMonitorEntry 4 }
-- Vlan-based port mirroring
pmCurCfgVlanMirrState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of vlan-based port mirroring."
::= { mirrVlanMirr 1 }
pmNewCfgVlanMirrState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The state of vlan-based port mirroring."
::= { mirrVlanMirr 2 }
pmCurCfgVlanMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmCurCfgVlanMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of vlan based port mirroring."
::= { mirrVlanMirr 3 }
pmCurCfgVlanMonitorEntry OBJECT-TYPE
SYNTAX PmCurCfgVlanMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the monitoring vlan table."
INDEX { pmCurCfgVmirrMoniPortIndex, pmCurCfgVmirrMirrVlanIndex }
::= { pmCurCfgVlanMonitorTable 1 }
PmCurCfgVlanMonitorEntry ::= SEQUENCE {
pmCurCfgVmirrMoniPortIndex INTEGER,
pmCurCfgVmirrMirrVlanIndex INTEGER,
pmCurCfgVmirrDirection INTEGER
}
pmCurCfgVmirrMoniPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The monitoring port number."
::= { pmCurCfgVlanMonitorEntry 1 }
pmCurCfgVmirrMirrVlanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mirrored vlan number"
::= { pmCurCfgVlanMonitorEntry 2 }
pmCurCfgVmirrDirection OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2),
both(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of traffic to be monitored with respect to the
mirrored vlan."
::= { pmCurCfgVlanMonitorEntry 3 }
pmNewCfgVlanMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmNewCfgVlanMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of vlan-based port mirroring."
::= { mirrVlanMirr 4 }
pmNewCfgVlanMonitorEntry OBJECT-TYPE
SYNTAX PmNewCfgVlanMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the monitoring vlan table."
INDEX { pmNewCfgVmirrMoniPortIndex, pmNewCfgVmirrMirrVlanIndex }
::= { pmNewCfgVlanMonitorTable 1 }
PmNewCfgVlanMonitorEntry ::= SEQUENCE {
pmNewCfgVmirrMoniPortIndex INTEGER,
pmNewCfgVmirrMirrVlanIndex INTEGER,
pmNewCfgVmirrDirection INTEGER,
pmNewCfgVmirrDelete INTEGER
}
pmNewCfgVmirrMoniPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The monitoring port number."
::= { pmNewCfgVlanMonitorEntry 1 }
pmNewCfgVmirrMirrVlanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mirrored vlan number"
::= { pmNewCfgVlanMonitorEntry 2 }
pmNewCfgVmirrDirection OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2),
both(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of traffic to be monitored with respect to the
mirrored vlan."
::= { pmNewCfgVlanMonitorEntry 3 }
pmNewCfgVmirrDelete OBJECT-TYPE
SYNTAX INTEGER {
other(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting the value to delete(2) will delete the entire
row. When read, other(1) is returned."
::= { pmNewCfgVlanMonitorEntry 4 }
-- Port CPU utilization table
portCpuStatsUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortCpuStatsUtilTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of port CPU utilization."
::= { portCpuStats 1 }
portCpuStatsUtilTableEntry OBJECT-TYPE
SYNTAX PortCpuStatsUtilTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port CPU utilization table."
INDEX { portCpuStatsUtilIndx }
::= { portCpuStatsUtilTable 1 }
PortCpuStatsUtilTableEntry ::= SEQUENCE {
portCpuStatsUtilIndx INTEGER,
portCpuAStatsUtil1Second INTEGER,
portCpuBStatsUtil1Second INTEGER,
portCpuAStatsUtil4Seconds INTEGER,
portCpuBStatsUtil4Seconds INTEGER,
portCpuAStatsUtil64Seconds INTEGER,
portCpuBStatsUtil64Seconds INTEGER
}
portCpuStatsUtilIndx OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index."
::= { portCpuStatsUtilTableEntry 1 }
portCpuAStatsUtil1Second OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU A over 1 second. It shows the percentage."
::= { portCpuStatsUtilTableEntry 2}
portCpuBStatsUtil1Second OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU B over 1 second. It shows the percentage."
::= { portCpuStatsUtilTableEntry 3}
portCpuAStatsUtil4Seconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU A over 4 seconds.
It shows the percentage."
::= { portCpuStatsUtilTableEntry 4}
portCpuBStatsUtil4Seconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU B over 4 seconds.
It shows the percentage."
::= { portCpuStatsUtilTableEntry 5}
portCpuAStatsUtil64Seconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU A over 64 seconds.
It shows the percentage."
::= { portCpuStatsUtilTableEntry 6}
portCpuBStatsUtil64Seconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The utilization of port CPU B over 64 seconds.
It shows the percentage."
::= { portCpuStatsUtilTableEntry 7}
-- Information Group
-- This group represents run-time status of the system
-- Port information table
portInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortInfoTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of port information."
::= { port-info 1 }
portInfoTableEntry OBJECT-TYPE
SYNTAX PortInfoTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port information table."
INDEX { portInfoIndx }
::= { portInfoTable 1 }
PortInfoTableEntry ::= SEQUENCE {
portInfoIndx INTEGER,
portInfoSpeed INTEGER,
portInfoMode INTEGER,
portInfoFlowCtrl INTEGER,
portInfoLink INTEGER,
portInfoPhyIfDescr DisplayString,
portInfoPhyIfType INTEGER,
portInfoPhyIfMtu INTEGER,
portInfoPhyIfPhysAddress PhysAddress,
portInfoPhyIfOperStatus INTEGER,
portInfoPhyIfLastChange TimeTicks
}
portInfoIndx OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index."
::= { portInfoTableEntry 1 }
portInfoSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbs10(2),
mbs100(3),
mbs1000(4),
any(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational speed of the port."
::= { portInfoTableEntry 2 }
portInfoMode OBJECT-TYPE
SYNTAX INTEGER {
full-duplex(2),
half-duplex(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational mode of the port."
::= { portInfoTableEntry 3 }
portInfoFlowCtrl OBJECT-TYPE
SYNTAX INTEGER {
transmit(2),
receive(3),
both(4),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational flow control of the port."
::= { portInfoTableEntry 4 }
portInfoLink OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
disabled(3),
inoperative(4) -- unrecognized PCI device
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational link status of the port."
::= { portInfoTableEntry 5 }
portInfoPhyIfDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface."
::= { portInfoTableEntry 6 }
portInfoPhyIfType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
regular1822(2),
hdh1822(3),
ddn-x25(4),
rfc877-x25(5),
ethernet-csmacd(6),
iso88023-csmacd(7),
iso88024-tokenBus(8),
iso88025-tokenRing(9),
iso88026-man(10),
starLan(11),
proteon-10Mbit(12),
proteon-80Mbit(13),
hyperchannel(14),
fddi(15),
lapb(16),
sdlc(17),
ds1(18), -- T-1
e1(19), -- european equiv. of T-1
basicISDN(20),
primaryISDN(21), -- proprietary serial
propPointToPointSerial(22),
ppp(23),
softwareLoopback(24),
eon(25), -- CLNP over IP [11]
ethernet-3Mbit(26),
nsip(27), -- XNS over IP
slip(28), -- generic SLIP
ultra(29), -- ULTRA technologies
ds3(30), -- T-3
sip(31), -- SMDS
frame-relay(32)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack."
::= { portInfoTableEntry 7 }
portInfoPhyIfMtu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the largest datagram which can be
sent/received on the interface, specified in
octets. For interfaces that are used for
transmitting network datagrams, this is the size
of the largest network datagram that can be sent
on the interface."
::= { portInfoTableEntry 8 }
portInfoPhyIfPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. For interfaces which do not have
such an address (e.g., a serial line), this object
should contain an octet string of zero length."
::= { portInfoTableEntry 9 }
portInfoPhyIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational state of the interface.
The testing(3) state indicates that no operational
packets can be passed."
::= { portInfoTableEntry 10 }
portInfoPhyIfLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the interface
entered its current operational state. If the
current state was entered prior to the last re-
initialization of the local network management
subsystem, then this object contains a zero
value."
::= { portInfoTableEntry 11 }
portStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortStatsTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of port statistics."
::= { port-stats 1 }
portStatsTableEntry OBJECT-TYPE
SYNTAX PortStatsTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port stats table."
INDEX { portStatsIndx }
::= { portStatsTable 1 }
PortStatsTableEntry ::=
SEQUENCE {
portStatsIndx
INTEGER,
portStatsPhyIfInOctets
Counter,
portStatsPhyIfInUcastPkts
Counter,
portStatsPhyIfInNUcastPkts
Counter,
portStatsPhyIfInDiscards
Counter,
portStatsPhyIfInErrors
Counter,
portStatsPhyIfInUnknownProtos
Counter,
portStatsPhyIfOutOctets
Counter,
portStatsPhyIfOutUcastPkts
Counter,
portStatsPhyIfOutNUcastPkts
Counter,
portStatsPhyIfOutDiscards
Counter,
portStatsPhyIfOutErrors
Counter,
portStatsPhyIfOutQLen
Gauge,
portStatsPhyIfInBroadcastPkts
Counter,
portStatsPhyIfOutBroadcastPkts
Counter
}
portStatsIndx OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index."
::= { portStatsTableEntry 1 }
portStatsPhyIfInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets received on the
interface, including framing characters."
::= { portStatsTableEntry 2 }
portStatsPhyIfInUcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of subnetwork-unicast packets
delivered to a higher-layer protocol."
::= { portStatsTableEntry 3 }
portStatsPhyIfInNUcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of non-unicast (i.e., subnetwork-
broadcast or subnetwork-multicast) packets
delivered to a higher-layer protocol."
::= { portStatsTableEntry 4 }
portStatsPhyIfInDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being deliverable to a
higher-layer protocol. One possible reason for
discarding such a packet could be to free up
buffer space."
::= { portStatsTableEntry 5 }
portStatsPhyIfInErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound packets that contained
errors preventing them from being deliverable to a
higher-layer protocol."
::= { portStatsTableEntry 6 }
portStatsPhyIfInUnknownProtos OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received via the interface
which were discarded because of an unknown or
unsupported protocol."
::= { portStatsTableEntry 7 }
portStatsPhyIfOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets transmitted out of the
interface, including framing characters."
::= { portStatsTableEntry 8 }
portStatsPhyIfOutUcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted to a
subnetwork-unicast address, including those that
were discarded or not sent."
::= { portStatsTableEntry 9 }
portStatsPhyIfOutNUcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted to a non-
unicast (i.e., a subnetwork-broadcast or
subnetwork-multicast) address, including those
that were discarded or not sent."
::= { portStatsTableEntry 10 }
portStatsPhyIfOutDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being transmitted. One
possible reason for discarding such a packet could
be to free up buffer space."
::= { portStatsTableEntry 11 }
portStatsPhyIfOutErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outbound packets that could not be
transmitted because of errors."
::= { portStatsTableEntry 12 }
portStatsPhyIfOutQLen OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The length of the output packet queue (in
packets)."
::= { portStatsTableEntry 13 }
portStatsPhyIfInBroadcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer."
::= { portStatsTableEntry 14 }
portStatsPhyIfOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent."
::= { portStatsTableEntry 15 }
mirrOper OBJECT IDENTIFIER ::= { operCmds 3 }
mirrOperMonitoringPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The switch port where the mirrored traffic are sent to. A zero
value indicates this field has not been configured."
::= { mirrOper 1 }
mirrOperMirroredPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The switch port where the egress traffic to be mirrored. A zero
value indicates this field has not been configured."
::= { mirrOper 2 }
mirrOperType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
in(2),
out(3),
both(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of packets to be sent to the monitor port.
in = packets received at the mirrored port
out = packets sent from the mirrored port
both = packets sent and received by the mirrored port
"
::= { mirrOper 3 }
mirrOperTimeout OBJECT-TYPE
SYNTAX INTEGER (0..86400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The duration in seconds for activating the mirroring rule. Zero
means forever."
::= { mirrOper 4 }
mirrOperState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable port mirroring."
::= { mirrOper 5 }
END