mibs/MIBS/arista/ARISTA-ENTITY-SENSOR-MIB

200 lines
6.8 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ARISTA-ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
entPhysicalIndex, entPhysicalDescr FROM ENTITY-MIB
entStateAlarm FROM ENTITY-STATE-MIB
EntitySensorValue, entPhySensorValue
FROM ENTITY-SENSOR-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
aristaMibs FROM ARISTA-SMI-MIB;
aristaEntSensorMIB MODULE-IDENTITY
LAST-UPDATED "201408150000Z"
ORGANIZATION "Arista Networks, Inc."
CONTACT-INFO
"Arista Networks, Inc.
Postal: 5453 Great America Parkway
Santa Clara, CA 95054
Tel: +1 408 547-5500
E-mail: snmp@arista.com"
DESCRIPTION
"This MIB module augments the entPhySensorTable of
ENTITY-SENSOR-MIB to provide threshold information for
various sensors in the system. For example, a given device
may have several voltage sensors as well as temperature
sensors each with appropriate threshold support to help
NMS systems detect and alert appropriately.
In addition, on systems where it is supported, if the
sensor value crosses the supported threshold value the system
can generate appropriate notification as well."
REVISION "201408150000Z"
DESCRIPTION "Updated postal and e-mail addresses."
REVISION "201305090950Z"
DESCRIPTION "Initial version of this MIB module."
::= { aristaMibs 12 }
-- Textual Conventions --
aristaEntSensorMibNotifications OBJECT IDENTIFIER
::= { aristaEntSensorMIB 0 }
aristaEntSensorMibObjects OBJECT IDENTIFIER
::= { aristaEntSensorMIB 1 }
aristaEntSensorMibConformance OBJECT IDENTIFIER
::= { aristaEntSensorMIB 2 }
-- entity threshold table --
aristaEntSensorThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AristaEntSensorThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains threshold information for the
various sensors in the system."
::= { aristaEntSensorMibObjects 1 }
aristaEntSensorThresholdEntry OBJECT-TYPE
SYNTAX AristaEntSensorThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single row containing threshold information for a
sensor. Threshold values are reported using the unit
of EntitySensorValue. If a sensor does not support threshold
data, then an underflow/overflow value is returned.
All the other relevant information for the given sensor can be
obtained from the entPhySensorTable itself."
INDEX { entPhysicalIndex }
::= { aristaEntSensorThresholdTable 1 }
AristaEntSensorThresholdEntry ::= SEQUENCE {
aristaEntSensorThresholdLowWarning EntitySensorValue,
aristaEntSensorThresholdLowCritical EntitySensorValue,
aristaEntSensorThresholdHighWarning EntitySensorValue,
aristaEntSensorThresholdHighCritical EntitySensorValue,
aristaEntSensorStatusDescr SnmpAdminString
}
aristaEntSensorThresholdLowWarning OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The low thresold value for the given sensor at which point
the entity's alarm status is set to warning."
::= { aristaEntSensorThresholdEntry 1 }
aristaEntSensorThresholdLowCritical OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The low critical value for the given sensor at which point
the entity's alarm status is set to critical."
::= { aristaEntSensorThresholdEntry 2 }
aristaEntSensorThresholdHighWarning OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The high thresold value for the given sensor at which point
the entity's alarm status is set to warning."
::= { aristaEntSensorThresholdEntry 3 }
aristaEntSensorThresholdHighCritical OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The high critical value for the given sensor at which point
the entity's alarm status is set to critical."
::= { aristaEntSensorThresholdEntry 4 }
aristaEntSensorStatusDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the current status of the sensor.
It serves as a human-readable representation of the operating
status including any threshold alerts."
::= { aristaEntSensorThresholdEntry 5 }
-- Notifications --
aristaEntSensorAlarm NOTIFICATION-TYPE
OBJECTS {
entPhysicalDescr, entPhySensorValue, entStateAlarm
}
STATUS current
DESCRIPTION
"This notification is generated under 2 conditions:
a) When the value of the sensor value crosses a supported
low or high threshold into warning or critical status.
b) If previously the sensor value was in a warning or
critical status but returns back to a normal status."
::= { aristaEntSensorMibNotifications 1 }
-- Conformance and Compliance
aristaEntSensorMibCompliances OBJECT IDENTIFIER
::= { aristaEntSensorMibConformance 1 }
aristaEntSensorMibGroups OBJECT IDENTIFIER
::= { aristaEntSensorMibConformance 2 }
aristaEntSensorMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for Arista switches that implement
the ARISTA-ENTITY-SENSOR-MIB."
MODULE -- this module
MANDATORY-GROUPS {
aristaEntSensorThresholdGroup,
aristaEntSensorNotificationsGroup
}
::= { aristaEntSensorMibCompliances 1 }
aristaEntSensorThresholdGroup OBJECT-GROUP
OBJECTS {
aristaEntSensorThresholdLowWarning,
aristaEntSensorThresholdLowCritical,
aristaEntSensorThresholdHighWarning,
aristaEntSensorThresholdHighCritical,
aristaEntSensorStatusDescr
}
STATUS current
DESCRIPTION
"The collection of objects that provide threshold
information for the sensors in the system."
::= { aristaEntSensorMibGroups 1 }
aristaEntSensorNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
aristaEntSensorAlarm
}
STATUS current
DESCRIPTION
"The collection of notifications generated by the system if
sensor(s) change value are not within the acceptable operating
range."
::= { aristaEntSensorMibGroups 2 }
END