mibs/MIBS/arris/ARRIS-C3-MAC-MIB

1114 lines
43 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ARRIS-C3-MAC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TimeInterval, RowStatus, TruthValue, DisplayString
FROM SNMPv2-TC
ifIndex
FROM IF-MIB -- RFC2233
TenthdBmV
FROM DOCS-IF-MIB -- RFC2670
TenthdB
FROM DOCS-IF-MIB -- RFC2670
cmtsC3
FROM ARRIS-MIB;
cmtsC3MACMIB MODULE-IDENTITY
LAST-UPDATED "200412030000Z" -- 3nd Dec 2004
ORGANIZATION "Arris International"
CONTACT-INFO
" Network Management
Postal: Arris International.
4400 Cork Airport Business Park
Cork Airport, Kinsale Road
Cork, Ireland.
Tel: +353 21 7305 800
Fax: +353 21 4321 972"
DESCRIPTION
"This MIB manages the MAC software on the Cadant C3 CMTS."
REVISION "200411210000Z"
DESCRIPTION
"Changes to support fully programmable IF frequency.
Added support for downstream wireless mode.
Updated some mib descriptions for clarity and typos.
Added mixed mode to DocsisMacType definition which defines a
docsis downstream and euro-docsis upstream configuration that is
used by some customers in lieu of annex C mode which the CMTS does
not support in hardware.
Added support for downstream wireless mode."
REVISION "200411260000Z"
DESCRIPTION
"Added dcxMACUpChannelinitialRangingDelay."
REVISION "200412030000Z"
DESCRIPTION
"Added dcxMACUccMaxFailedAttempts."
::= { cmtsC3 6 }
DocsisMacType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the DOCSIS Channel Type."
SYNTAX INTEGER {
docsis (1),
euroDocsis (2),
mixed (3),
custom(4)
}
dcxMACObjects OBJECT IDENTIFIER ::= { cmtsC3MACMIB 1 }
dcxMACCmtsMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional columns for docsIfCmtsMacTable.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
::= { dcxMACObjects 1 }
dcxMACCmtsMacEntry OBJECT-TYPE
SYNTAX DcxMACCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"dcxMACCmtsMacEntry"
INDEX {ifIndex}
::= { dcxMACCmtsMacTable 1 }
DcxMACCmtsMacEntry ::= SEQUENCE {
dcxMACCmtsMacMode DocsisMacType,
dcxMACCableAdvanceType INTEGER,
dcxMACPlantLength Unsigned32,
dcxMACFlapAgingTime Unsigned32,
dcxMACFlapInsertTime Unsigned32,
dcxMACFlapMissThresh Unsigned32,
dcxMACFlapListSize Unsigned32,
dcxMACCmOfflineAgingTime Unsigned32,
dcxMACUccMaxFailedAttempts Unsigned32
}
dcxMACCmtsMacMode OBJECT-TYPE
SYNTAX DocsisMacType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode in which the MAC is operating. A read to this
value may return any of the modes defined by DocsisMacType. Only
the modes docsis, euroDocsis and mixed may be written.
When set to docsis or euroDocsis, all downstream and upstream
channels in this MAC domain will be configured in DOCSIS or
EuroDOCSIS mode respectively. When set to mixed, the downstream
channels will be configured in DOCSIS and the upstream channels
will be running in EuroDOCSIS mode.
The value custom will be returned in a read operation if any of
the underlying channels has been reconfigured in such a way that
the MAC can not be described a docsis, euroDocsis or mixed."
::= { dcxMACCmtsMacEntry 1 }
dcxMACCableAdvanceType OBJECT-TYPE
SYNTAX INTEGER { static(0), dynamic(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Map Advance Type - 0 for Static, 1 for Dynamic."
::= { dcxMACCmtsMacEntry 2 }
dcxMACPlantLength OBJECT-TYPE
SYNTAX Unsigned32 (0..161)
UNITS "kilometers"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Plant Length (1-way) in kilometers."
::= { dcxMACCmtsMacEntry 3 }
dcxMACFlapAgingTime OBJECT-TYPE
SYNTAX Unsigned32 (0..864000)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Flap List Aging Time in seconds."
::= { dcxMACCmtsMacEntry 4 }
dcxMACFlapInsertTime OBJECT-TYPE
SYNTAX Unsigned32 ( 0..86400 )
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Flap List Insertion Time threshold in seconds."
::= { dcxMACCmtsMacEntry 5 }
dcxMACFlapMissThresh OBJECT-TYPE
SYNTAX Unsigned32 (0..12)
UNITS "misses"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Flap List Miss Threshold in misses."
::= { dcxMACCmtsMacEntry 6 }
dcxMACFlapListSize OBJECT-TYPE
SYNTAX Unsigned32 (0..6000)
UNITS "entries"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable Flap List Maximum Number of Entries."
::= { dcxMACCmtsMacEntry 8 }
dcxMACCmOfflineAgingTime OBJECT-TYPE
SYNTAX Unsigned32 (3600..864000)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cable modem offline aging time in seconds. Minimum value
is 1 hour. Maximum time before aging a modem is 10 days.
Default value is 24 hours."
DEFVAL { 86400 }
::= { dcxMACCmtsMacEntry 9 }
dcxMACUccMaxFailedAttempts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of consecutive failed channel change attempts that
a modem is allowed before the CMTS decides to no longer use the
modem for load balancing purposes.
If a modem successfully completes a channel change before the
maximum number of attempts is reached, the number of consecutive
failed attempts for the modem is reset.
A value of 0 indicates no limit."
DEFVAL { 2 }
::= { dcxMACCmtsMacEntry 10 }
dcxMACDownstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional columns for docsIfDownstreamChannelTable.
An entry in this table exists for each ifEntry with an
ifType of docsCableDownstream(128)."
::= { dcxMACObjects 2 }
dcxMACDownstreamChannelEntry OBJECT-TYPE
SYNTAX DcxMACDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"dcxMACDownstreamChannelEntry"
INDEX {ifIndex}
::= { dcxMACDownstreamChannelTable 1 }
DcxMACDownstreamChannelEntry ::= SEQUENCE {
dcxMACDownChannelMacMode DocsisMacType,
dcxMACDownChannelUpconverter INTEGER,
dcxMACDownChannelIfFrequency Integer32,
dcxMACDownChannelWirelessMode INTEGER,
dcxMACDownChannelSymbolRate Integer32,
dcxMACDownChannelAlpha Integer32
}
dcxMACDownChannelMacMode OBJECT-TYPE
SYNTAX DocsisMacType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the downstream to DOCSIS or EuroDOCSIS.
When dcxMACDownChannelWirelessMode is disabled, changes to this
will impact the downstream annex type, modulation, symbol rate
and interleaver. When wireless mode is enabled, only the annex
type and interleaver will be changed."
::= { dcxMACDownstreamChannelEntry 1 }
dcxMACDownChannelUpconverter OBJECT-TYPE
SYNTAX INTEGER { internal(1), external(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether or not the internal upconverter is used.
If set to internal, the downstream IF frequency will operate
in read-only mode and will be configured internally by the
CMTS based on the downstream channel configuration.
If set to external, the IF frequency may be programmed to set the
frequency supplied to an external upconverter via the IF output.
In this mode, the downstream RF frequency and power will both
return 0 when read."
::= { dcxMACDownstreamChannelEntry 2 }
dcxMACDownChannelIfFrequency OBJECT-TYPE
SYNTAX Integer32 (10000000..60000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IF frequency output by the modulator for this channel."
::= { dcxMACDownstreamChannelEntry 3 }
dcxMACDownChannelWirelessMode OBJECT-TYPE
SYNTAX INTEGER { active(1), inactive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling this mode allows non-standard downstream modulations and
symbol rates to be configured which are suitable when using the
CMTS in a wireless application. Changes to dcxMACDownChannelMacMode
when wireless mode is active will only impact the downstream annex
type and interleaver settings. Modulation and symbol rates will
only be affected when wireless mode is disabled.
Disabling wireless mode will reset any non-standard modulation and
symbol rates settings in order to restore a standard DOCSIS or
EuroDOCSIS downstream.
If a set to active fails, a license may be required to activate the
feature."
::= { dcxMACDownstreamChannelEntry 4 }
dcxMACDownChannelSymbolRate OBJECT-TYPE
SYNTAX Integer32 (1250000..6952000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the downstream symbol rate."
::= { dcxMACDownstreamChannelEntry 5 }
dcxMACDownChannelAlpha OBJECT-TYPE
SYNTAX Integer32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of excess bandwidth for the channel."
::= { dcxMACDownstreamChannelEntry 6 }
dcxMACUpstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional columns for docsIfUpstreamChannelTable.
An entry in this table exists for each ifEntry with an
ifType of docsCableUpstream(129)."
::= { dcxMACObjects 3 }
dcxMACUpstreamChannelEntry OBJECT-TYPE
SYNTAX DcxMACUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"dcxMACUpstreamChannelEntry"
INDEX {ifIndex}
::= { dcxMACUpstreamChannelTable 1 }
DcxMACUpstreamChannelEntry ::= SEQUENCE {
dcxMACUpChannelMacMode DocsisMacType,
dcxMACUpChannelAmpAttenuation TenthdBmV,
dcxMACUpChannelIngressCancellation INTEGER,
dcxMACUpChannelGroupId Unsigned32,
dcxMACUpChannelShortPollInterval TimeInterval,
dcxMACUpChannelPeriodicPollInterval TimeInterval,
dcxMACUpChannelInputPowerMode INTEGER,
dcxMACUpChannelPower TenthdBmV,
dcxMACUpChannelPlantLength Unsigned32,
dcxMACUpChannelMaxCmMapProcTime Unsigned32,
dcxMACUpChannelConcatenation TruthValue,
dcxMACUpChannelSpMgtTriggerIndex Unsigned32,
dcxMACUpChannelLowPowerOffset TenthdBmV,
dcxMACUpChannelHighPowerOffset TenthdBmV,
dcxMACUpChannelLogSnrAveTimeconstant Unsigned32,
dcxMACUpChannelImpulseMitigation INTEGER,
dcxMACUpChannelRngPreambleGuardSymbols Unsigned32,
dcxMACUpChannelNrngPreambleGuardSymbols Unsigned32,
dcxMACUpChannelExtendedFrequencyErrorDetect INTEGER,
dcxMACUpChannelLogC3SnrTimeconstant Unsigned32,
dcxMACUpChannelSignalNoise TenthdB,
dcxMACUpChannelSafeConfig TruthValue,
dcxMACUpChannelInitialRangingDelay Unsigned32
}
dcxMACUpChannelMacMode OBJECT-TYPE
SYNTAX DocsisMacType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode in which this upstream is operating. A read or
write to this may consist only of the values docsis or euroDocsis."
::= { dcxMACUpstreamChannelEntry 1 }
dcxMACUpChannelAmpAttenuation OBJECT-TYPE
SYNTAX TenthdBmV
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amplifier attenuation level for this logical
channel."
::= { dcxMACUpstreamChannelEntry 2 }
dcxMACUpChannelIngressCancellation OBJECT-TYPE
SYNTAX INTEGER { disabled(1), tdmaOnly(2), scdmaSec(3), scdmaInc1(4), scdmaInc2(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the ingress noise cancellation mode for this
logical channel. Not all modes may be valid for a
given logical channel configuration or hardware."
::= { dcxMACUpstreamChannelEntry 3 }
dcxMACUpChannelGroupId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The group ID for this logical channel used to associate it
with other upsteams on the same physical network. The group ID
is an index into the dcxMACUpstreamGroupTable which defines common
parameters for grouped upsteams. Upstreams do not have to be
grouped and there may be more than one group on the same physical
network. Spatially diverse upstreams should not have the same group ID."
::= { dcxMACUpstreamChannelEntry 4 }
dcxMACUpChannelShortPollInterval OBJECT-TYPE
SYNTAX TimeInterval (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The short interval for initial unicast maintanance on this logical
channel."
::= { dcxMACUpstreamChannelEntry 5 }
dcxMACUpChannelPeriodicPollInterval OBJECT-TYPE
SYNTAX TimeInterval (100..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The periodic station maintanance interval on this logical channel."
::= { dcxMACUpstreamChannelEntry 6 }
dcxMACUpChannelInputPowerMode OBJECT-TYPE
SYNTAX INTEGER { fixed(1), automatic(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The receiver input power mode for this logical channel. In fixed
mode the input power to the demodulator will remain fixed across
symbol rate changes. In automatic mode the demodulator may vary the
input power for optimal performance."
::= { dcxMACUpstreamChannelEntry 7 }
dcxMACUpChannelPower OBJECT-TYPE
SYNTAX TenthdBmV
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The nominal receiver input power for this logical channel."
::= { dcxMACUpstreamChannelEntry 8 }
dcxMACUpChannelPlantLength OBJECT-TYPE
SYNTAX Unsigned32 (1..320)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cable length in km to the most distant CM on this logical
upstream."
::= { dcxMACUpstreamChannelEntry 9 }
dcxMACUpChannelMaxCmMapProcTime OBJECT-TYPE
SYNTAX Unsigned32 (0..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time in microseconds allowed for modems on this logical
channel to process the Upstream Bandwidth Allocation MAP."
::= { dcxMACUpstreamChannelEntry 10 }
dcxMACUpChannelConcatenation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the use of packet concatenation by Cable Modems on
this logical channel."
::= { dcxMACUpstreamChannelEntry 11 }
dcxMACUpChannelSpMgtTriggerIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An index into spectral management trigger table, identical
to dcxMACSpMgtTriggerIndex in that table. All entries with
the same value of dcxMACSpMgtTriggerIndex form a trigger group
all assigned to the same logical upstream channel or group.
Returns 0 if there are no triggers assigned to this logical
channel."
::= { dcxMACUpstreamChannelEntry 12 }
dcxMACUpChannelLowPowerOffset OBJECT-TYPE
SYNTAX TenthdBmV (-100..-10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum power offset of a burst below the nominal
input power to the CMTS that will not cause a RNG-RSP
with status continue. Valid range is from -10 dBmV to
-1 dBmV in 1 dB increments."
DEFVAL { -60 }
::= { dcxMACUpstreamChannelEntry 13 }
dcxMACUpChannelHighPowerOffset OBJECT-TYPE
SYNTAX TenthdBmV (10..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum power offset of a burst above the nominal
input power to the CMTS that will not cause a RNG-RSP
with status continue. Valid range is from +1 dBmV to
+10 dBmV in 1 dB increments."
DEFVAL { 60 }
::= { dcxMACUpstreamChannelEntry 14 }
dcxMACUpChannelLogSnrAveTimeconstant OBJECT-TYPE
SYNTAX Unsigned32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The averaging timeconstant used to calculate the per-logical channel
MIB variable docsIfSigQSignalNoise. The averaging uses a logarithmic
scale, so that the actual timeconstant used is 2^X, where X is the
value configured for this object. Increasing the value of X increases
the degree to which the SNR results are averaged over time, and reduces
the sensitivity of the reported channel SNR to local oscillations in
signal quality. Averaging can effectively be disabled by setting this
object to 0"
DEFVAL { 2 }
::= { dcxMACUpstreamChannelEntry 15 }
dcxMACUpChannelImpulseMitigation OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables impulse noise mitigation for this
logical channel."
::= { dcxMACUpstreamChannelEntry 16 }
dcxMACUpChannelRngPreambleGuardSymbols OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of guard symbols before the preamble pilot pattern for
ranging bursts. Guard symbols may help the receiver to mitigate
the effects of ISI and\or help with the detection of bursts with
an early arrival time"
::= { dcxMACUpstreamChannelEntry 17 }
dcxMACUpChannelNrngPreambleGuardSymbols OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of guard symbols before the preamble pilot pattern for
non-ranging bursts. Guard symbols may help the receiver to mitigate
the effects of ISI and\or help with the detection of bursts with
an early arrival time"
::= { dcxMACUpstreamChannelEntry 18 }
dcxMACUpChannelExtendedFrequencyErrorDetect OBJECT-TYPE
SYNTAX INTEGER { none(0),
initialRanging(1),
periodicRanging(2),
allRanging(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offsets in carrier frequency in the modem are corrected by the CMTS
during ranging. Typically most if not all off the frequency error is
removed in the initial ranging response with incremental changes removed
during periodic ranging. If large frequency offsets are expected during
initial or periodic ranging, this value may be configured to provide
extended frequency offset detection and correction."
DEFVAL { none }
::= { dcxMACUpstreamChannelEntry 19 }
dcxMACUpChannelLogC3SnrTimeconstant OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The averaging timeconstant used to calculate the per-logical channel
MIB variable dcxMACUpChannelSignalNoise. The averaging uses a logarithmic
scale, so that the actual timeconstant used is 2^X, where X is the
value configured for this object. Increasing the value of X increases
the degree to which the SNR results are averaged over time, and reduces
the sensitivity of the reported channel SNR to local oscillations in
signal quality. Averaging can effectively be disabled by setting this
object to 0"
::= { dcxMACUpstreamChannelEntry 20 }
dcxMACUpChannelSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A measurement of the average signal/noise ratio for the logical upstream.
The averaging may be controlled using the dcxMACUpChannelLogC3SnrTimeconstant
variable"
::= { dcxMACUpstreamChannelEntry 21 }
dcxMACUpChannelSafeConfig OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, MIB SETs which would cause this logical channel to go offline will return
a failure"
::= { dcxMACUpstreamChannelEntry 22 }
dcxMACUpChannelInitialRangingDelay OBJECT-TYPE
SYNTAX Unsigned32 (300..3000)
UNITS "microseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of extra microseconds to allow in a broadcast IUC3
grant to compensate for modems that perform initial ranging later
than expected."
::= { dcxMACUpstreamChannelEntry 23 }
dcxMACUpstreamGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACUpstreamGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries containing definitions for group IDs
that can be associated with an upstream channel."
::= { dcxMACObjects 4 }
dcxMACUpstreamGroupEntry OBJECT-TYPE
SYNTAX DcxMACUpstreamGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"dcxMACUpstreamGroupEntry"
INDEX {
dcxMACUpstreamGroupId
}
::= { dcxMACUpstreamGroupTable 1 }
DcxMACUpstreamGroupEntry ::= SEQUENCE {
dcxMACUpstreamGroupId Unsigned32,
dcxMACUpstreamGroupName OCTET STRING,
dcxMACUpstreamGroupLoadBalancing INTEGER,
dcxMACUpstreamGroupFrequencyIndex Unsigned32,
dcxMACUpstreamGroupSpMgtTriggerIndex Unsigned32,
dcxMACUpstreamGroupStatus RowStatus
}
dcxMACUpstreamGroupId OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID for this group."
::= { dcxMACUpstreamGroupEntry 1 }
dcxMACUpstreamGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..63))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name associated with this group"
::= { dcxMACUpstreamGroupEntry 2 }
dcxMACUpstreamGroupLoadBalancing OBJECT-TYPE
SYNTAX INTEGER { none(1), initialNumeric(2), periodic(3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configures upstream load balancing for the group.
Options are: none, initialNumeric, periodic.
If set to none, no load balancing will be performed.
If set to initialNumeric, the CMTS may redirect modems to other active upstream
channels in the same group by setting the upstream channel ID override in the
RNG-RSP at any time up to the point where the modem successfully completes
periodic ranging. Once a modem has completed ranging it must be reset before it
may be moved to another upstream. The modems in a group will be distributed
evenly and numerically across the active channels in the group. When a modems
performs initial ranging, it will be sent to the upsteam with the least number
of active modems if the number of active modems on the current upsteam is greater
than the average number of modems per upsteam in the group. All channels are
treated equally when calculating loads.
If a modem fails to range on the desired channel following a ranging overide,
it will be allowed to remain on the channel on which it next performs initial
ranging.
If set to periodic, modems will be numerically distributed during initial ranging
and then selectively moved after registration using UCC. Periodic load balancing
will attempt to distribute the modems to maintain even bandwidth utilization across
the channels in a group."
DEFVAL { none }
::= { dcxMACUpstreamGroupEntry 3 }
dcxMACUpstreamGroupFrequencyIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An index into upstream frequency table, identical to
dcxMACUpstreamFrequencyIndex in that table. All entries
with the same value of dcxMACUpstreamFrequencyIndex form
a spectral frequency group all assigned to the same
upstream group. Returns 0 if there are no triggers assigned
to this group."
::= { dcxMACUpstreamGroupEntry 4 }
dcxMACUpstreamGroupSpMgtTriggerIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An index into spectral management trigger table, identical
to dcxMACSpMgtTriggerIndex in that table. All entries with
the same value of dcxMACSpMgtTriggerIndex form a trigger group
all assigned to the same upstream group or channel. Returns 0 if
there are no triggers assigned to this group."
::= { dcxMACUpstreamGroupEntry 5 }
dcxMACUpstreamGroupStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create rows in this table"
::= { dcxMACUpstreamGroupEntry 6 }
dcxMACUpstreamFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACUpstreamFrequencyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the upstream spectrum available for use by one or more
upstream groups. Entries are grouped by dcxMACUpstreamFrequencyIndex,
with each group assigned to one or more upstream groups."
::= { dcxMACObjects 5 }
dcxMACUpstreamFrequencyEntry OBJECT-TYPE
SYNTAX DcxMACUpstreamFrequencyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a single contiguous region of upstream spectrum, available for
use by one or more upstream spectral groups."
INDEX { dcxMACUpstreamFrequencyIndex, dcxMACUpstreamFrequencyRegion }
::= { dcxMACUpstreamFrequencyTable 1 }
DcxMACUpstreamFrequencyEntry ::= SEQUENCE {
dcxMACUpstreamFrequencyIndex Unsigned32,
dcxMACUpstreamFrequencyRegion Unsigned32,
dcxMACUpstreamFrequencyStart Integer32,
dcxMACUpstreamFrequencyStop Integer32,
dcxMACUpstreamFrequencyStatus RowStatus
}
dcxMACUpstreamFrequencyIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the upstream frequency table representing
a group of spectral regions, all associated with the
same upstream spectral group."
::= { dcxMACUpstreamFrequencyEntry 1 }
dcxMACUpstreamFrequencyRegion OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the upstream frequency table which, when
grouped with other frequency regions with the same frequency
index fully describe the upstream frequency spectrum available
for use by a given spectral group."
::= { dcxMACUpstreamFrequencyEntry 2 }
dcxMACUpstreamFrequencyStart OBJECT-TYPE
SYNTAX Integer32
UNITS "hertz"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The start frequency for this upstream spectral region."
::= { dcxMACUpstreamFrequencyEntry 3 }
dcxMACUpstreamFrequencyStop OBJECT-TYPE
SYNTAX Integer32
UNITS "hertz"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The stop frequency for this upstream spectral region."
::= { dcxMACUpstreamFrequencyEntry 4 }
dcxMACUpstreamFrequencyStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create entries in this table."
::= { dcxMACUpstreamFrequencyEntry 5 }
dcxMACSpectralMgtObjects OBJECT IDENTIFIER ::= { dcxMACObjects 6 }
dcxMACSpectralMgtTriggerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACSpectralMgtTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the spectral management triggers assigned to one
or more upstream groups or channels. Entries are grouped by
dcxMACSpMgtTriggerIndex, with each group assigned to one or more
upstream channels or groups."
::= { dcxMACSpectralMgtObjects 1 }
dcxMACSpectralMgtTriggerEntry OBJECT-TYPE
SYNTAX DcxMACSpectralMgtTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a single spectral management trigger, available for
use by one or more upstream channels or spectral groups."
INDEX { dcxMACSpMgtTriggerIndex, dcxMACSpMgtTriggerNumber }
::= { dcxMACSpectralMgtTriggerTable 1 }
DcxMACSpectralMgtTriggerEntry::= SEQUENCE {
dcxMACSpMgtTriggerIndex Unsigned32,
dcxMACSpMgtTriggerNumber Unsigned32,
dcxMACSpMgtTriggerType Integer32,
dcxMACSpMgtTriggerAction Unsigned32,
dcxMACSpMgtTriggerParam1 Integer32,
dcxMACSpMgtTriggerParam2 Integer32,
dcxMACSpMgtTriggerParam3 Integer32,
dcxMACSpMgtTriggerParam4 Integer32,
dcxMACSpMgtTriggerParam5 Integer32,
dcxMACSpMgtTriggerParam6 Integer32,
dcxMACSpMgtTriggerParam7 Integer32,
dcxMACSpMgtTriggerParam8 Integer32,
dcxMACSpMgtTriggerStatus RowStatus
}
dcxMACSpMgtTriggerIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the spectral managment trigger table
representing a group of triggers, all assigned to
the same upstream channel or spectral group."
::= { dcxMACSpectralMgtTriggerEntry 1 }
dcxMACSpMgtTriggerNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the spectral managment trigger table which,
when grouped with other triggers with the same trigger
index fully describe the spectral mangement triggers
assigned to the same upstream channel or spectral group."
::= { dcxMACSpectralMgtTriggerEntry 2 }
dcxMACSpMgtTriggerType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the trigger type represented by this entry."
::= { dcxMACSpectralMgtTriggerEntry 3 }
dcxMACSpMgtTriggerAction OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An index into the spectral management action table,
identical to dcxMACSpMgtActionIndex in that table,
identifying the action to take if this trigger is
invoked. Returns 0 if there is no action associated
with this trigger."
::= { dcxMACSpectralMgtTriggerEntry 4 }
dcxMACSpMgtTriggerParam1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 5 }
dcxMACSpMgtTriggerParam2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 6 }
dcxMACSpMgtTriggerParam3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 7 }
dcxMACSpMgtTriggerParam4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 8 }
dcxMACSpMgtTriggerParam5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 9 }
dcxMACSpMgtTriggerParam6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 10 }
dcxMACSpMgtTriggerParam7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 11 }
dcxMACSpMgtTriggerParam8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on trigger type."
::= { dcxMACSpectralMgtTriggerEntry 12 }
dcxMACSpMgtTriggerStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create and control the status of entries in this table."
::= { dcxMACSpectralMgtTriggerEntry 13 }
dcxMACSpectralMgtActionTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACSpectralMgtActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the spectral management actions assigned to one
or more spectral managment triggers."
::= { dcxMACSpectralMgtObjects 2 }
dcxMACSpectralMgtActionEntry OBJECT-TYPE
SYNTAX DcxMACSpectralMgtActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a single spectral management action, assigned to
one or more spectral management triggers."
INDEX { dcxMACSpMgtActionIndex }
::= { dcxMACSpectralMgtActionTable 1 }
DcxMACSpectralMgtActionEntry::= SEQUENCE {
dcxMACSpMgtActionIndex Unsigned32,
dcxMACSpMgtActionType Integer32,
dcxMACSpMgtActionParam1 Integer32,
dcxMACSpMgtActionParam2 Integer32,
dcxMACSpMgtActionParam3 Integer32,
dcxMACSpMgtActionParam4 Integer32,
dcxMACSpMgtActionParam5 Integer32,
dcxMACSpMgtActionParam6 Integer32,
dcxMACSpMgtActionParam7 Integer32,
dcxMACSpMgtActionParam8 Integer32,
dcxMACSpMgtActionStatus RowStatus
}
dcxMACSpMgtActionIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the spectral managment actions table
used to assign actions to spectral management triggers."
::= { dcxMACSpectralMgtActionEntry 1 }
dcxMACSpMgtActionType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the action type represented by this entry."
::= { dcxMACSpectralMgtActionEntry 2 }
dcxMACSpMgtActionParam1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 3 }
dcxMACSpMgtActionParam2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 4 }
dcxMACSpMgtActionParam3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 5 }
dcxMACSpMgtActionParam4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 6 }
dcxMACSpMgtActionParam5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 7 }
dcxMACSpMgtActionParam6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 8 }
dcxMACSpMgtActionParam7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 9 }
dcxMACSpMgtActionParam8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Parameter dependent on action type."
::= { dcxMACSpectralMgtActionEntry 10 }
dcxMACSpMgtActionStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create and control the status of entries in this table."
::= { dcxMACSpectralMgtActionEntry 11 }
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
-- Shared Secret configuration
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
dcxMACSharedSecretTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcxMACSharedSecretEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Set up shared secrets for this DOCSIS MAC Interface"
::= { dcxMACObjects 7 }
dcxMACSharedSecretEntry OBJECT-TYPE
SYNTAX DcxMACSharedSecretEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"dcxMACSharedSecretEntry"
INDEX {ifIndex, dcxMACSharedSecretId}
::= { dcxMACSharedSecretTable 1 }
DcxMACSharedSecretEntry ::= SEQUENCE {
dcxMACSharedSecretId Integer32,
dcxMACSharedSecretStr DisplayString,
dcxMACSharedSecretStatus RowStatus
}
dcxMACSharedSecretId OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ID for the associated shared secret."
::= { dcxMACSharedSecretEntry 1 }
dcxMACSharedSecretStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the shared secret itself, which is considered write-only. It can be SET
but when a GET operation is performed the value is not returned."
::= { dcxMACSharedSecretEntry 2 }
dcxMACSharedSecretStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status."
::= { dcxMACSharedSecretEntry 3 }
END