mibs/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB

182 lines
4.8 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ARRIS-D5-ENT-SENSOR-THRESH-MIB DEFINITIONS ::= BEGIN
IMPORTS
packetport, cm110, tcm, ttm, ttp,
cmtsMSAS, cmts1500, cmtsC3, cmtsC4, cmtsCommon,
mrcController, arrisGlobalAccessMib, arrisGlobalAccessProductUas, arrisD5UEQam
FROM ARRIS-MIB
entPhysicalIndex, entityPhysicalGroup
FROM ENTITY-MIB
entPhySensorType, entPhySensorScale, entPhySensorPrecision, entPhySensorValue, entPhySensorOperStatus,
entPhySensorUnitsDisplay, entPhySensorValueTimeStamp, entPhySensorValueUpdateRate, entitySensorCompliance, entitySensorValueGroup,
entPhySensorEntry
FROM ENTITY-SENSOR-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI;
-- 1.3.6.1.4.1.4115.1.7.1.4
arrisEntSensorThreshMIB MODULE-IDENTITY
LAST-UPDATED "200710100000Z" -- 10th Oct 2007
ORGANIZATION
"Arris"
CONTACT-INFO
"Cindy Tromer
Postal: Arris Interactive
3871 Lakefield Drive
Suite 300
Suwanee, GA 30024-1242
U.S.A.
Phone: +1 770 622 8679
E-mail: cindy.tromer@arrisi.com
Initial MIB creator: Cindy Tromer
Postal: Arris Interactive
3871 Lakefield Drive
Suite 300
Suwanee, GA 30024-1242
U.S.A.
Phone: +1 770 622 8679
E-mail: cindy.tromer@arrisi.com
"
DESCRIPTION
"This is the extension Module to rfc3433 ENTITY-SENSOR-MIB."
::= { arrisD5UEQam 4 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.4115.1.7.1.4.1
entThreshObjects OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 1 }
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1
entThreshTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntThreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per physical sensor.
Each row contains the set of thresholds maintained
for each pyhsical sensor."
::= { entThreshObjects 1 }
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1
entThreshEntry OBJECT-TYPE
SYNTAX EntThreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The threshold information for a particular
physical sensor.
An entry in this table describes the upper and lower warning
thresholds, as well as the upper and lower fatal thresholds."
AUGMENTS { entPhySensorEntry }
::= { entThreshTable 1 }
EntThreshEntry ::=
SEQUENCE {
entLowerWarnThresh
Integer32,
entUpperWarnThresh
Integer32,
entLowerFatalThresh
Integer32,
entUpperFatalThresh
Integer32
}
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.1
entLowerWarnThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower warning threshold for a physical sensor.
When a sensor value goes below this threshold, the
system will continue to operate, but the craftperson
should evaluate the problem. "
::= { entThreshEntry 1 }
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.2
entUpperWarnThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper warning threshold for a physical sensor.
When a sensor value goes above this threshold, the
system will continue to operate, but the craftperson
should evaluate the problem. "
::= { entThreshEntry 2 }
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.3
entLowerFatalThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower fatal threshold for a physical sensor.
When a sensor value goes below this threshold, the
system will shutdown."
::= { entThreshEntry 3 }
-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.4
entUpperFatalThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper fatal threshold for a physical sensor.
When a sensor value goes above this threshold, the
system will shutdown."
::= { entThreshEntry 4 }
-- 1.3.6.1.4.1.4115.1.7.1.4.2
entThreshConformance OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 2 }
-- 1.3.6.1.4.1.4115.1.7.1.4.2.1
entThreshCompliances OBJECT IDENTIFIER ::= { entThreshConformance 1 }
-- 1.3.6.1.4.1.4115.1.7.1.4.2.1.1
entThreshCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Description."
MODULE -- this module
MANDATORY-GROUPS { entThreshValueGroup }
::= { entThreshCompliances 1 }
-- 1.3.6.1.4.1.4115.1.7.1.4.2.2
entThreshGroups OBJECT IDENTIFIER ::= { entThreshConformance 2 }
-- 1.3.6.1.4.1.4115.1.7.1.4.2.2.1
entThreshValueGroup OBJECT-GROUP
OBJECTS { entLowerWarnThresh, entUpperWarnThresh, entUpperFatalThresh, entLowerFatalThresh }
STATUS current
DESCRIPTION
"Description."
::= { entThreshGroups 1 }
END