ARRIS-D5-SLOT-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32,
Counter32, Gauge32, IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowStatus, DisplayString,
TimeStamp, DateAndTime
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
ifIndex, InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB
arrisD5UEQam
FROM ARRIS-MIB;
d5SlotExtMIB MODULE-IDENTITY
LAST-UPDATED "200906100000Z"
ORGANIZATION "Arris Group, Inc"
CONTACT-INFO
" Network Management
Postal: Arris Group
3871 Lakefield Drive
Suwanee, GA 30324
Tel: 678 473 8500"
DESCRIPTION
"This MIB manages the slot assignments on the
Arris D5 DMTS."
::= { arrisD5UEQam 18 }
d5SlotObjects OBJECT IDENTIFIER ::= { d5SlotExtMIB 1 }
WAN7 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The wan card in slot 7."
SYNTAX Unsigned32 (7)
WAN8 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The wan card in slot 8."
SYNTAX Unsigned32 (8)
WanValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Wan card selection for slot assignment."
SYNTAX Unsigned32 (WAN7 | WAN8)
-- Slot Assignment
-- Provides mechanisms to assign slots to wan cards
slotAssignmentTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlotAssignmentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual table for slot assignments."
::= { d5SlotObjects 1 }
slotAssignmentEntry OBJECT-TYPE
SYNTAX SlotAssignmentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row entry of this table."
INDEX { ifIndex }
::= { slotAssignmentTable 1 }
SlotAssignmentEntry ::=
SEQUENCE {
dualWanEnable INTEGER,
slot1Assignment WanValue,
slot2Assignment WanValue,
slot3Assignment WanValue,
slot4Assignment WanValue,
slot5Assignment WanValue,
slot6Assignment WanValue
}
dualWanEnable OBJECT-TYPE
SYNTAX INTEGER {
dualWanDisabled(0),
dualWanEnabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable dual wan operation."
DEFVAL { FALSE }
::= { slotAssignmentEntry 1 }
slot1Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 2 }
slot2Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 3 }
slot3Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 4 }
slot4Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 5 }
slot5Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 6 }
slot6Assignment OBJECT-TYPE
SYNTAX WanValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assign the slot to the specified wan card."
DEFVAL { WAN7 }
::= { slotAssignmentEntry 7 }
--
--
--
identifyWan OBJECT-TYPE
SYNTAX INTEGER ( 0..16 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identify the WAN slot in a dual wan configuration."
::= { d5SlotObjects 2 }
END