mibs/MIBS/avaya/AV-SME-PLATFORM-MIB

335 lines
9.8 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--========================================================
--
-- MIB : SME Platform Avaya Inc.
--
-- Version : 0.03.00 11 January 2013
--
--========================================================
--
-- Copyright (c) 2013 Avaya Inc.
-- All Rights Reserved.
--
--========================================================
AV-SME-PLATFORM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
sysDescr
FROM SNMPv2-MIB
ItuPerceivedSeverity
FROM ITU-ALARM-TC-MIB
ifIndex
FROM IF-MIB
mibs
FROM AVAYAGEN-MIB
;
avSMEPlatformMIB MODULE-IDENTITY
LAST-UPDATED "201301111405Z" -- 11 January 2013
ORGANIZATION "Avaya Inc."
CONTACT-INFO
"Avaya Customer Services
Postal: Avaya, Inc.
211 Mt Airy Rd.
Basking Ridge, NJ 07920
USA
Tel: +1 908 953 6000
WWW: http://www.avaya.com"
DESCRIPTION
"Avaya IP Office MIBs OID tree.
This MIB module defines the root items for MIBs for
use with Avaya SME Embedded Platform."
REVISION "201301111405Z" -- 11 January 2013
DESCRIPTION
"Rev 0.03.00
Added the WebManagement application value for smepGTEventAppIdentity."
REVISION "201007061347Z" -- 06 July 2010
DESCRIPTION
"Rev 0.02.00
Corrected base OID to one properly allocated in Avaya tree."
REVISION "201007021437Z" -- 02 July 2010
DESCRIPTION
"Rev 0.01.00
The first rough draft of this MIB module."
::= { mibs 48 }
-- sub-tree for SME Embedded Platform wide objects and events
-- irrespective of function
smepGeneric OBJECT IDENTIFIER ::= { avSMEPlatformMIB 1 }
-- sub-tree for SME Embedded Platform functional MIBs
smepGenMibs OBJECT IDENTIFIER ::= { smepGeneric 1 }
-- sub-tree for SME EMbedded Platform wide traps/notifications
smepGenTraps OBJECT IDENTIFIER ::= { smepGeneric 2 }
-- sub-tree for SME Embedded Platform wide conformance information
smepGenConformance OBJECT IDENTIFIER ::= { smepGeneric 3 }
--********************************************************************
-- SME Embedded Platform wide traps/notifications
--********************************************************************
smepGTEvents OBJECT IDENTIFIER ::= { smepGenTraps 0 }
smepGTObjects OBJECT IDENTIFIER ::= { smepGenTraps 1 }
--
-- trap objects
--
smepGTEventStdSeverity OBJECT-TYPE
SYNTAX ItuPerceivedSeverity
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Severity of the event that has occurred.
The event severity depends upon the type of
entity/notification that the operational state change event
relates to. The severity values that are normally used are
detailed below:
The enterprise versions of standard SNMP traps all have a
severity of major (4).
GenAppEvents:
Severity depends on event condition
crash - severity is critical (3)"
::= { smepGTObjects 1 }
smepGTEventDateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Date and time of the occurence of the event."
::= { smepGTObjects 2 }
smepGTEventDevID OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (10))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique textual identifier of the alarming device."
::= { smepGTObjects 3 }
smepGTEventAppEntity OBJECT-TYPE
SYNTAX INTEGER {
voiceMailPro(1),
onex(2),
ipOffice(3),
jade(4),
webmanagement(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The SME Embedded Platform application to which a
notification/trap relates."
::= { smepGTObjects 4 }
smepGTEventAppEvent OBJECT-TYPE
SYNTAX INTEGER {
crash(1) -- severity: Critical
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"SME Embedded Platform application event states. The
associated event severity of the notification/trap the object
is carried in varies depending upon the event condition. The
appropriate severity is detailed against event enumeration."
::= { smepGTObjects 5 }
--
-- traps
--
smepGenColdStartEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr
}
STATUS current
DESCRIPTION
"Enterprise version of standard coldstart trap featuring
device identification information. A coldStart trap
signifies that the sending protocol entity is reinitializing
itself such that the agent's configuration or the protocol
entity implementation may be altered."
::= { smepGTEvents 1 }
smepGenWarmStartEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr
}
STATUS current
DESCRIPTION
"Enterprise version of standard warmstart trap featuring
device identification information. A warmStart trap
signifies that the sending protocol entity is reinitializing
that neither the agent configuration nor the protocol entity
implementation is altered."
::= { smepGTEvents 2 }
smepGenLinkDownEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr,
ifIndex
}
STATUS current
DESCRIPTION
"Enterprise version of standard linkDown trap featuring device
identification information. A linkDown trap signifies that
the sending protocol entity recognizes a failure in one of
the communication links represented in the agent's
configuration."
::= { smepGTEvents 3 }
smepGenLinkUpEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr,
ifIndex
}
STATUS current
DESCRIPTION
"Enterprise version of standard linkUp trap featuring device
identification information. A linkUp trap signifies that the
sending protocol entity recognizes that one of the
communication links represented in the agent's configuration
has come up."
::= { smepGTEvents 4 }
smepGenAuthFailureEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr
}
STATUS current
DESCRIPTION
"Enterprise version of standard authenticationFailure trap
featuring device identification information. An
authenticationFailure trap signifies that the sending
protocol entity is the addressee of a protocol message that
is not properly authenticated. While implementations of the
SNMP must be capable of generating this trap, they must also
be capable of suppressing the emission of such traps via an
implementation- specific mechanism."
::= { smepGTEvents 5 }
smepGenAppEvent NOTIFICATION-TYPE
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDateTime,
smepGTEventDevID,
sysDescr,
smepGTEventAppEntity,
smepGTEventAppEvent
}
STATUS current
DESCRIPTION
"A smepGenAppEvent notification is generated whenever a
application entity of the SME Embedded Platform experiences an
event. It signifies that the SNMP entity, acting as a proxy
for the application, has detected an event on the application
entity.
The event severity varies dependent upon the event condition."
::= { smepGTEvents 6 }
--********************************************************************
-- SME Embedded Platform wide compliance
--********************************************************************
smepGenCompliances OBJECT IDENTIFIER ::= { smepGenConformance 1 }
smepGenGroups OBJECT IDENTIFIER ::= { smepGenConformance 2 }
--
-- compliance statements
--
smepGenCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for SME Embedded Platform agents
which implement this MIB."
MODULE -- this module
MANDATORY-GROUPS {
smepGenNotificationObjectsGroup,
smepGenEntGenNotificationsGroup,
smepGenAppNotificationsGroup
}
::= { smepGenCompliances 1 }
--
-- MIB groupings
--
smepGenNotificationObjectsGroup OBJECT-GROUP
OBJECTS {
smepGTEventStdSeverity,
smepGTEventDevID,
smepGTEventDateTime,
smepGTEventAppEntity,
smepGTEventAppEvent
}
STATUS current
DESCRIPTION
"Objects that are contained in SME Embedded Platform wide
notifications."
::= { smepGenGroups 1 }
smepGenEntGenNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
smepGenColdStartEvent,
smepGenWarmStartEvent,
smepGenLinkDownEvent,
smepGenLinkUpEvent,
smepGenAuthFailureEvent
}
STATUS current
DESCRIPTION
"SME Embedded Platform Enterpise versions of the generic traps
as defined RFC1215 that provide more identification of the entity
concerned."
::= { smepGenGroups 2 }
smepGenAppNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
smepGenAppEvent
}
STATUS current
DESCRIPTION
"The service notifications which indicate specific changes in
the state of Applications on the SME Embedded Platform."
::= { smepGenGroups 3 }
END