-- AT-CHASSIS.MIB, Allied Telesis enterprise MIB:
-- Objects for chassis information
-- Copyright (c) 2011 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================
AT-CHASSIS-MIB DEFINITIONS ::= BEGIN
IMPORTS
sysinfo
FROM AT-SMI-MIB
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
chassis MODULE-IDENTITY
LAST-UPDATED "201406090000Z"
ORGANIZATION
"Allied Telesis, Inc."
CONTACT-INFO
" http://www.alliedtelesis.com"
DESCRIPTION
"Support for accessing trap notifications on chassis based products."
REVISION "201406090000Z"
DESCRIPTION
"Added sofware version to chassisCardTable."
REVISION "201405260000Z"
DESCRIPTION
"Added new chassisMappingTable for mapping node ID to member ID."
REVISION "201404160000Z"
DESCRIPTION
"Added more descriptions to chassisCardSlot for VCStack Plus and
increase the range to 1-24."
REVISION "201205150000Z"
DESCRIPTION
"Added support for the controller cards and line cards."
REVISION "201109260000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { sysinfo 23 }
--
-- Node definitions
--
--
-- The VCS Notification Objects (For RFC3584 compliance)
--
chassisNotifications OBJECT IDENTIFIER ::= { chassis 0 }
chassisCardRoleChangeNotify NOTIFICATION-TYPE
OBJECTS { slotNumber, chassisRole }
STATUS current
DESCRIPTION
"A notification generated when the CFC's role is changed."
::= { chassisNotifications 1 }
chassisCardJoinNotify NOTIFICATION-TYPE
OBJECTS { slotNumber }
STATUS current
DESCRIPTION
"A notification generated when a card connects to the CFC."
::= { chassisNotifications 2 }
chassisCardLeaveNotify NOTIFICATION-TYPE
OBJECTS { slotNumber }
STATUS current
DESCRIPTION
"A notification generated when a card detaches from the CFC."
::= { chassisNotifications 3 }
slotNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..12)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Slot number of the card that has changed."
::= { chassisNotifications 4 }
chassisRole OBJECT-TYPE
SYNTAX INTEGER
{
leaving(1),
discovering(2),
synchronizing(3),
standbyMember(4),
pendingMaster(5),
disabledMaster(6),
activeMaster(7)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"CFC's role in the chassis."
::= { chassisNotifications 5 }
--
-- The card table
--
chassisCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChassisCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of cards presented on the device."
::= { chassis 1 }
chassisCardEntry OBJECT-TYPE
SYNTAX ChassisCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about a card."
INDEX { chassisCardSlot }
::= { chassisCardTable 1 }
ChassisCardEntry ::=
SEQUENCE {
chassisCardSlot
INTEGER,
chassisCardBoardOID
OBJECT IDENTIFIER,
chassisCardName
DisplayString,
chassisCardState
INTEGER,
chassisCardControllerState
INTEGER,
chassiCardSwVersion
DisplayString
}
chassisCardSlot OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number the card is in. For VCStack Plus,
1-12 refers to the cards on VCS stack member 1 and
13-24 refers to the cards on VCS stack member 2.
Refer to chassisMappingTable for more details."
::= { chassisCardEntry 1 }
chassisCardBoardOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OID value used to identify the type of board
that is defined in the alliedTelesis's 'boards'
enterprise MIB.
If the board is provisioned or an unsupported
hardware, this object will have the value of 0 0."
::= { chassisCardEntry 2 }
chassisCardName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the card. E.g. AT-SBx81CFC400, AT-SBx81CFC960 for
controller cards; AT-SBx81GP24, AT-SBx81GT24, AT-SBx81GS24,
AT-SBx81XS6 for line cards; 'unknown' for unsupported hardware."
::= { chassisCardEntry 3 }
chassisCardState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
configuring(2),
syncing(3),
online(4),
syncingFirmware(5),
joining(6),
incompatibleSW(7),
disabled(8),
initializing(9),
booting(10),
unsupportedHW(11),
provisioned(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the card. The valid state is in one of the following:
unknown(1), configuring(2), syncing(3), online(4), syncingFirmware(5),
joining(6), incompatibleSW(7), disabled(8), initializing(9),
booting(10), unsupportedHW(11) or provisioned(12)."
::= { chassisCardEntry 4 }
chassisCardControllerState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
active(2),
standby(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the controller card, in addition to the
card state. The valid state is in one of the following:
unknown(1), active(2) or standby(3)."
::= { chassisCardEntry 5 }
chassiCardSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version that the card is running. When feature ISSU (In Service
Software Update) is supported, there are situations that a LIF card may run
a software version different from the active CFC."
::= { chassisCardEntry 6 }
--
-- Map from node id to VCS member and slot id
--
chassisMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChassisMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of cards presented on the device."
::= { chassis 2 }
chassisMappingEntry OBJECT-TYPE
SYNTAX ChassisMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Other SNMP SET/GET operations refer to a card in a chassis using a
single integer index, i.e. a 'node-ID'. This table entry maps a node-ID
value to the VCS member-ID and slot number of the card. For example,
node-ID 17 would map to card 2.5 (VCS member-ID 2, slot 5)."
INDEX { chassisNodeId }
::= { chassisMappingTable 1 }
ChassisMappingEntry ::=
SEQUENCE {
chassisNodeId
Unsigned32,
chassisVCSMemberId
Unsigned32,
chassisSlotNumber
Unsigned32,
chassisNodeDisplayString
DisplayString,
chassisNodeStateString
DisplayString
}
chassisNodeId OBJECT-TYPE
SYNTAX Unsigned32 (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node ID of a chassis card."
::= { chassisMappingEntry 1 }
chassisVCSMemberId OBJECT-TYPE
SYNTAX Unsigned32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCS member ID of the chassis that the card is in."
::= { chassisMappingEntry 2 }
chassisSlotNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The chassis slot number that the card is installed in."
::= { chassisMappingEntry 3 }
chassisNodeDisplayString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the chassis card. E.g. 'card 1.5'."
::= { chassisMappingEntry 4 }
chassisNodeStateString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the card for the bay. If the card is present state is
displayed as online, or if the bay is provisioned it will be displayed as
Provisioned."
::= { chassisMappingEntry 5 }
END
--