mibs/MIBS/awplus/AT-PLUGGABLE-DIAGNOSTICS-MIB

662 lines
22 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ============================================================================
-- AT-PLUGGABLE-DIAGNOSTICS-MIB, Allied Telesis enterprise MIB:
-- Diagnostic objects related to Optical Pluggable modules.
--
-- Copyright (c) 2015 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================
AT-PLUGGABLE-DIAGNOSTICS-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayStringUnsized
FROM AT-SMI-MIB
sysinfo
FROM AT-SYSINFO-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB;
atPluggableDiag MODULE-IDENTITY
LAST-UPDATED "201507170000Z"
ORGANIZATION "Allied Telesis, Inc"
CONTACT-INFO "http://www.alliedtelesis.com"
DESCRIPTION
"The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard
diagnostic information from installed SFP modules."
REVISION "201507170000Z"
DESCRIPTION "Initial revision"
::= { sysinfo 28 }
----------------------------------------------------------------
-- The Digital Diagnostic monitoring for optical pluggables
----------------------------------------------------------------
atPluggableDiagTable OBJECT IDENTIFIER ::= { atPluggableDiag 1 }
----------------------------------------------------------------
-- Temperature table for Digital Diagnostic monitoring
----------------------------------------------------------------
atPluggableDiagTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the various temperature parameters observed
as a part of Digital diagnostics monitoring, for all the optical pluggables
installed in the devices."
::= { atPluggableDiagTable 1 }
atPluggableDiagTempEntry OBJECT-TYPE
SYNTAX AtPluggableDiagTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various temperature parameters of pluggables
such as current status reading, current alarm status, higher and lower
alarm threshold, current warning, higher and lower warning threshold."
INDEX { atPluggableDiagTempIfIndex, atPluggableDiagTempChannel }
::= { atPluggableDiagTempTable 1 }
AtPluggableDiagTempEntry ::= SEQUENCE {
atPluggableDiagTempIfIndex InterfaceIndex,
atPluggableDiagTempChannel Integer32,
atPluggableDiagTempStatusReading Integer32,
atPluggableDiagTempCurrentAlarm OCTET STRING,
atPluggableDiagTempAlarmMax Integer32,
atPluggableDiagTempAlarmMin Integer32,
atPluggableDiagTempCurrentWarning OCTET STRING,
atPluggableDiagTempWarningMax Integer32,
atPluggableDiagTempWarningMin Integer32 }
atPluggableDiagTempIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagTempEntry 1 }
atPluggableDiagTempChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagTempEntry 2 }
atPluggableDiagTempStatusReading OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 degree C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature status reading."
::= { atPluggableDiagTempEntry 3 }
atPluggableDiagTempCurrentAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature alarm reading."
::= { atPluggableDiagTempEntry 4 }
atPluggableDiagTempAlarmMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 degree C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum temperature alarm threshold value."
::= { atPluggableDiagTempEntry 5 }
atPluggableDiagTempAlarmMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 degree C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum temperature alarm threshold value."
::= { atPluggableDiagTempEntry 6 }
atPluggableDiagTempCurrentWarning OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature warnings."
::= { atPluggableDiagTempEntry 7 }
atPluggableDiagTempWarningMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 degree C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum temperature warning threshold value."
::= { atPluggableDiagTempEntry 8 }
atPluggableDiagTempWarningMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 degree C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum temperature warning threshold value."
::= { atPluggableDiagTempEntry 9 }
----------------------------------------------------------------
-- Voltage (Vcc) table for Digital Diagnostic monitoring
----------------------------------------------------------------
atPluggableDiagVccTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagVccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the various Voltage (Vcc) parameters observed
as a part of Digital diagnostics monitoring, for all the optical pluggables
installed in the devices."
::= { atPluggableDiagTable 2 }
atPluggableDiagVccEntry OBJECT-TYPE
SYNTAX AtPluggableDiagVccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various Voltage (Vcc) parameters of pluggables
such as current status reading, current alarm status, higher and lower
alarm threshold, current warning, higher and lower warning threshold."
INDEX { atPluggableDiagVccIfIndex, atPluggableDiagVccChannel }
::= { atPluggableDiagVccTable 1 }
AtPluggableDiagVccEntry ::= SEQUENCE {
atPluggableDiagVccIfIndex InterfaceIndex,
atPluggableDiagVccChannel Integer32,
atPluggableDiagVccStatusReading Integer32,
atPluggableDiagVccCurrentAlarm OCTET STRING,
atPluggableDiagVccAlarmMax Integer32,
atPluggableDiagVccAlarmMin Integer32,
atPluggableDiagVccCurrentWarning OCTET STRING,
atPluggableDiagVccWarningMax Integer32,
atPluggableDiagVccWarningMin Integer32 }
atPluggableDiagVccIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagVccEntry 1 }
atPluggableDiagVccChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagVccEntry 2 }
atPluggableDiagVccStatusReading OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Voltage (Vcc) status reading."
::= { atPluggableDiagVccEntry 3 }
atPluggableDiagVccCurrentAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Voltage (Vcc) alarm reading."
::= { atPluggableDiagVccEntry 4 }
atPluggableDiagVccAlarmMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Voltage (Vcc) alarm threshold value."
::= { atPluggableDiagVccEntry 5 }
atPluggableDiagVccAlarmMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Voltage (Vcc) alarm threshold value."
::= { atPluggableDiagVccEntry 6 }
atPluggableDiagVccCurrentWarning OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Voltage (Vcc) warnings."
::= { atPluggableDiagVccEntry 7 }
atPluggableDiagVccWarningMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Voltage (Vcc) warning threshold value."
::= { atPluggableDiagVccEntry 8 }
atPluggableDiagVccWarningMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Voltage (Vcc) warning threshold value."
::= { atPluggableDiagVccEntry 9 }
----------------------------------------------------------------
-- Tx Bias Current (mA) table for Digital Diagnostic monitoring
----------------------------------------------------------------
atPluggableDiagTxBiasTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagTxBiasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the various Tx Bias Current (mA)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices."
::= { atPluggableDiagTable 3 }
atPluggableDiagTxBiasEntry OBJECT-TYPE
SYNTAX AtPluggableDiagTxBiasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various Tx Bias Current (mA)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold."
INDEX { atPluggableDiagTxBiasIfIndex, atPluggableDiagTxBiasChannel }
::= { atPluggableDiagTxBiasTable 1 }
AtPluggableDiagTxBiasEntry ::= SEQUENCE {
atPluggableDiagTxBiasIfIndex InterfaceIndex,
atPluggableDiagTxBiasChannel Integer32,
atPluggableDiagTxBiasStatusReading Integer32,
atPluggableDiagTxBiasCurrentAlarm OCTET STRING,
atPluggableDiagTxBiasAlarmMax Integer32,
atPluggableDiagTxBiasAlarmMin Integer32,
atPluggableDiagTxBiasCurrentWarning OCTET STRING,
atPluggableDiagTxBiasWarningMax Integer32,
atPluggableDiagTxBiasWarningMin Integer32 }
atPluggableDiagTxBiasIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagTxBiasEntry 1 }
atPluggableDiagTxBiasChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagTxBiasEntry 2 }
atPluggableDiagTxBiasStatusReading OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Bias (mA) status reading."
::= { atPluggableDiagTxBiasEntry 3 }
atPluggableDiagTxBiasCurrentAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Bias (mA) alarm reading."
::= { atPluggableDiagTxBiasEntry 4 }
atPluggableDiagTxBiasAlarmMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Tx Bias (mA) alarm threshold value."
::= { atPluggableDiagTxBiasEntry 5 }
atPluggableDiagTxBiasAlarmMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Tx Bias (mA) alarm threshold value."
::= { atPluggableDiagTxBiasEntry 6 }
atPluggableDiagTxBiasCurrentWarning OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Bias (mA) warnings."
::= { atPluggableDiagTxBiasEntry 7 }
atPluggableDiagTxBiasWarningMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Tx Bias (mA) warning threshold value."
::= { atPluggableDiagTxBiasEntry 8 }
atPluggableDiagTxBiasWarningMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Tx Bias (mA) warning threshold value."
::= { atPluggableDiagTxBiasEntry 9 }
----------------------------------------------------------------
-- Tx Power (mW) table for Digital Diagnostic monitoring
----------------------------------------------------------------
atPluggableDiagTxPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagTxPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the various Tx Power (mW)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices."
::= { atPluggableDiagTable 4 }
atPluggableDiagTxPowerEntry OBJECT-TYPE
SYNTAX AtPluggableDiagTxPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various Tx Power (mW)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold."
INDEX { atPluggableDiagTxPowerIfIndex, atPluggableDiagTxPowerChannel }
::= { atPluggableDiagTxPowerTable 1 }
AtPluggableDiagTxPowerEntry ::= SEQUENCE {
atPluggableDiagTxPowerIfIndex InterfaceIndex,
atPluggableDiagTxPowerChannel Integer32,
atPluggableDiagTxPowerStatusReading Integer32,
atPluggableDiagTxPowerCurrentAlarm OCTET STRING,
atPluggableDiagTxPowerAlarmMax Integer32,
atPluggableDiagTxPowerAlarmMin Integer32,
atPluggableDiagTxPowerCurrentWarning OCTET STRING,
atPluggableDiagTxPowerWarningMax Integer32,
atPluggableDiagTxPowerWarningMin Integer32 }
atPluggableDiagTxPowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagTxPowerEntry 1 }
atPluggableDiagTxPowerChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagTxPowerEntry 2 }
atPluggableDiagTxPowerStatusReading OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Power (mW) status reading."
::= { atPluggableDiagTxPowerEntry 3 }
atPluggableDiagTxPowerCurrentAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Power (mW) alarm reading."
::= { atPluggableDiagTxPowerEntry 4 }
atPluggableDiagTxPowerAlarmMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Tx Power (mW) alarm threshold value."
::= { atPluggableDiagTxPowerEntry 5 }
atPluggableDiagTxPowerAlarmMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Tx Power (mW) alarm threshold value."
::= { atPluggableDiagTxPowerEntry 6 }
atPluggableDiagTxPowerCurrentWarning OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx Power (mW) warnings."
::= { atPluggableDiagTxPowerEntry 7 }
atPluggableDiagTxPowerWarningMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Tx Power (mW) warning threshold value."
::= { atPluggableDiagTxPowerEntry 8 }
atPluggableDiagTxPowerWarningMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Tx Power (mW) warning threshold value."
::= { atPluggableDiagTxPowerEntry 9 }
----------------------------------------------------------------
-- Rx Power (mW) table for Digital Diagnostic monitoring
----------------------------------------------------------------
atPluggableDiagRxPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagRxPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the various Rx Power (mW)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices."
::= { atPluggableDiagTable 5 }
atPluggableDiagRxPowerEntry OBJECT-TYPE
SYNTAX AtPluggableDiagRxPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various Rx Power (mW)
parameters of pluggables such as current status reading,
current alarm status, higher and lower alarm threshold,
current warning, higher and lower warning threshold."
INDEX { atPluggableDiagRxPowerIfIndex, atPluggableDiagRxPowerChannel }
::= { atPluggableDiagRxPowerTable 1 }
AtPluggableDiagRxPowerEntry ::= SEQUENCE {
atPluggableDiagRxPowerIfIndex InterfaceIndex,
atPluggableDiagRxPowerChannel Integer32,
atPluggableDiagRxPowerStatusReading Integer32,
atPluggableDiagRxPowerCurrentAlarm OCTET STRING,
atPluggableDiagRxPowerAlarmMax Integer32,
atPluggableDiagRxPowerAlarmMin Integer32,
atPluggableDiagRxPowerCurrentWarning OCTET STRING,
atPluggableDiagRxPowerWarningMax Integer32,
atPluggableDiagRxPowerWarningMin Integer32 }
atPluggableDiagRxPowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagRxPowerEntry 1 }
atPluggableDiagRxPowerChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagRxPowerEntry 2 }
atPluggableDiagRxPowerStatusReading OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Rx Power (mW) status reading."
::= { atPluggableDiagRxPowerEntry 3 }
atPluggableDiagRxPowerCurrentAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Rx Power (mW) alarm reading."
::= { atPluggableDiagRxPowerEntry 4 }
atPluggableDiagRxPowerAlarmMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Rx Power (mW) alarm threshold value."
::= { atPluggableDiagRxPowerEntry 5 }
atPluggableDiagRxPowerAlarmMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Rx Power (mW) alarm threshold value."
::= { atPluggableDiagRxPowerEntry 6 }
atPluggableDiagRxPowerCurrentWarning OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Rx Power (mW) warnings."
::= { atPluggableDiagRxPowerEntry 7 }
atPluggableDiagRxPowerWarningMax OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Rx Power (mW) warning threshold value."
::= { atPluggableDiagRxPowerEntry 8 }
atPluggableDiagRxPowerWarningMin OBJECT-TYPE
SYNTAX Integer32
UNITS "0.0001 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Rx Power (mW) warning threshold value."
::= { atPluggableDiagRxPowerEntry 9 }
-----------------------------------------------------------------------
-- Rx Loss of Signal (LOS) table for Digital Diagnostic monitoring
-----------------------------------------------------------------------
atPluggableDiagRxLosTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtPluggableDiagRxLosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information regarding the Rx Loss of Singal (Los)
parameters observed as a part of Digital diagnostics monitoring,
for all the optical pluggables installed in the devices."
::= { atPluggableDiagTable 6 }
atPluggableDiagRxLosEntry OBJECT-TYPE
SYNTAX AtPluggableDiagRxLosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about various Rx Loss of Singal (Los) parameters
of pluggables such as current status reading."
INDEX { atPluggableDiagRxLosIfIndex, atPluggableDiagRxLosChannel }
::= { atPluggableDiagRxLosTable 1 }
AtPluggableDiagRxLosEntry ::= SEQUENCE {
atPluggableDiagRxLosIfIndex InterfaceIndex,
atPluggableDiagRxLosChannel Integer32,
atPluggableDiagRxLosStatusReading OCTET STRING }
atPluggableDiagRxLosIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the pluggable."
::= { atPluggableDiagRxLosEntry 1 }
atPluggableDiagRxLosChannel OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number of the pluggable."
::= { atPluggableDiagRxLosEntry 2 }
atPluggableDiagRxLosStatusReading OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Rx Los status reading."
::= { atPluggableDiagRxLosEntry 3 }
END