mibs/MIBS/bktel/BKTEL-HFC862-OVTX-V11-MIB

2001 lines
70 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--- ****************************************************************************
-- *
-- * Description: Implements definitions for the Ovtx-modul
-- * (External Modulated Optical Transmitters)
-- *
-- * Copyright 2003 by BKtel communications GmbH
-- *
-- * V.0.1 18.02.03 J. Anhorn first draft
-- * V.0.2 17.03.03 M. Heldmann ovtxStates group changed completely, more changes
-- * V.0.3 23.04.03 M. Heldmann ovtxDisplay group shrinked, removed J.Anhorns comments
-- * V.0.4 30.04.03 M. Heldmann ovtxControlReset, ovtxControlModuleLedBlink added
-- * V.0.5 05.05.03 M. Heldmann ovtxStatesLaserShutdown, ovtxStatesInitializing added
-- * V.0.6 23.07.03 M. Heldmann added descriptions for the states
-- * V.0.7 16.09.03 M. Heldmann adjusted description for the state ovtxStatesInputLow
-- * V.1.0 17.12.03 M. Heldmann added ovtxRfInputMin..ovtxRfInputMax
-- * ovtxStatesInputHigh, ovtxStatesRedundancySwitch
-- * ovtxConfigurationRfInputLimitLoLo..ovtxConfigurationMaskExtIO
-- * ovtxDisplayOmiNominal
-- * renamed ovtxControlLaserShutdown to ovtxControlLaserOutputMode and expanded it
-- * renamed ..ItuFrequency.. to ..LaserFrequency..
-- * adjusted some descriptions
-- * V.1.1 27.02.04 M. Heldmann changed ExtIOmask parameter name from maskUnknown(3) to maskSpecial(3)
-- * V.1.2 01.09.04 M. Heldmann ovtxConfigurationSbsSuppression expanded to SBS on/off settings
-- * V.1.3 18.04.05 M. Heldmann ovtxConfigurationSbsSuppression changed description
-- * V.1.4 04.10.06 M. Heldmann NESlotWriteValue expanded due to new 2G6 platform needs
-- * V.2.0 14.01.08 M. Heldmann renamed threshold parameters in ovtxMeasuringValuesTable
-- * renamed ovtxStatesDefective -> ovtxStatesCommLoss
-- * some threshold parameters in ovtxMeasuringValuesTable made read-write
-- * parameters needed for new transmitter hardware with extended features:
-- * - ovtxConfigurationCsoRegulationMode, ovtxConfigurationSlope
-- * ovtxConfigurationFiberLength configuration parameters
-- * - ovtxDisplayRegulationState, ovtxDisplayExtendedCapabilities
-- * parameters needed for new transmitter hardware with SAT RF input:
-- * - ovtxSatRfInputValue, ovtxSatOmiMeasuredValue,
-- * ovtxSatRfGainMeasuredValue measuring values and their thresholds
-- * - ovtxStatesSatInputLow, ovtxStatesSatInputHigh.
-- * ovtxStatesSatOmiOrRfgainLow. ovtxStatesSatOmiOrRfgainHigh alarm states
-- * - ovtxConfigurationSatModeAGC, ovtxConfigurationSatOmi, ovtxConfigurationSatRfGain
-- * ovtxConfigurationSatSlope, ovtxConfigurationRfInputMode configuration parameters
-- * - ovtxDisplaySatOmiNominal, ovtxDisplayRfInputCapabilities
-- * V.2.1 26.06.09 M. Heldmann added ovtxConfigurationSatLnbSupply and ovtxDisplaySatLnbSupplySupported
-- * V.2.1b 14.05.10 M. Heldmann renamed ovtxConfigurationModeExtIO and ovtxConfigurationMaskExtIO
-- * to ovtxConfigurationRedundancyMode and ovtxConfigurationRedundancyMask
-- * V.2.2 27.04.12 M. Heldmann added ovtxStatesSatLnbShortCircuit, ovtxStatesSbs1Level, ovtxStatesSbs2Level
-- * ovtxStatesSbs1PllNotLocked ovtxStatesSbs2PllNotLocked
-- * ovtxConfigurationSbsSuppressionMode,
-- * ovtxDisplaySbsExtensionsSupported, ovtxDisplaySbsSuppressionModeSupported
-- * V.2.2b 03.12.12 M. Heldmann added ovtxStatesInternalAlarm
-- * V.2.2c 20.03.13 M. Heldmann changed ovtxConfigurationSbsSuppressionMode to ovtxConfigurationSbsSuppressionMode
-- * added ovtxConfigurationSbsFiberType, ovtxConfigurationSbsFiberLength and
-- * ovtxDisplaySbsFiberParametersSupported
-- * V.2.3 11.07.13 M. Heldmann adjusted syntax of "CommonEntry" to remove MIB compiler warnings
-- * V.2.4 05.09.14 M. Heldmann changed CommonModuleWidth and ConfigurationNESlotWrite STATUS to optional
-- ****************************************************************************
BKTEL-HFC862-OVTX-V11-MIB DEFINITIONS ::= BEGIN
IMPORTS
experimental, enterprises, TimeTicks, IpAddress, Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
modules, DisplayString, TruthValue, PerceivedSeverityValue, NESlotValue, ModuleWidthValue
FROM BKTEL-HFC862-BASE-MIB
;
ovtx OBJECT IDENTIFIER ::= { modules 101 }
ovtxCommon OBJECT IDENTIFIER ::= { ovtx 1 }
ovtxStates OBJECT IDENTIFIER ::= { ovtx 2 }
ovtxConfiguration OBJECT IDENTIFIER ::= { ovtx 3 }
ovtxControl OBJECT IDENTIFIER ::= { ovtx 4 }
ovtxMeasuringValues OBJECT IDENTIFIER ::= { ovtx 5 }
ovtxDisplay OBJECT IDENTIFIER ::= { ovtx 6 }
--
-- Type definitions
--
AGCmode ::= INTEGER
{
modeAgcOff(1),
modeUnmodulatedAgcOn(2),
modeModulatedAgcOn(3)
}
SatAGCmode ::= INTEGER
{
satAgcOff(1),
satAgcOn(2)
}
RedundancyMode ::= INTEGER
{
modeActiveLowOutput(1),
modeActiveHighOutput(2),
modeNominalMasterIrreversible(3),
modeNominalMasterFallback(4),
modeRedundantSlave(5)
}
RedundancyMask ::= INTEGER
{
maskAlarmsOnly(1),
maskAlarmsAndWarnings(2),
maskSpecialAdjusted(3) -- This item is NOT writable !!
}
LaserOutputMode ::= INTEGER
{
laserShutdown(1),
laserActive(2),
laserShutdownOnMaskedError(3) -- Automatic laser shutdown on RedundancyMask'ed error condition
}
CsoRegulationMode ::= INTEGER
{
csoRegModeChannelControlled(1),
csoRegModePilotControlled(2)
}
RegulationState ::= INTEGER
{
regulationStateUnknownOrNotSupported(1),
regulationStateOutputpowerBased(2),
regulationStateCsoBasedRough(3),
regulationStateCsoBasedFine(4),
regulationStatePilotBased(5)
}
RfInputCapabilities ::= INTEGER
{
rfInputCatvOnlySupported(1),
rfInputSatOnlySupported(2),
rfInputCatvAndSatSupported(3)
}
RfInputAlarmMode ::= INTEGER
{
alarmEnableAll(1),
alarmCatvEnableSatDisable(2),
alarmSatEnableCatvDisable(3)
}
LnbSupplyValue ::= INTEGER
{
lnbSupplyOff(1),
lnbSupply14V(2),
lnbSupply18V(3),
lnbSupply14V_22kHz(4),
lnbSupply18V_22kHz(5)
}
LnbSupplySupportedValue ::= INTEGER
{
notSupported(1),
lnbSupply14V18VSwitchSupported(2),
lnbSupply14V18VAnd22kHzSwitchSupported(3)
}
SbsSuppressionModeValue ::= INTEGER
{
modeStandard(1),
modeCatvOnly(2)
}
SbsFiberTypeValue ::= INTEGER
{
typeStandardFiber(1),
typeSbsOptimizedFiber(2)
}
SbsFiberLengthValue ::= INTEGER
{
length10km(1),
length25km(2),
length40km(3),
length65km(4)
}
NESlotWriteValue ::= INTEGER (-1..99)
--*****************************************************************************************
-- OVTX ( Optical Transmitter with design release V11 )
--*****************************************************************************************
-- ovtxCommon group
ovtxCommonNumberOfModules OBJECT-TYPE
SYNTAX INTEGER(0..50)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Number of modules in table."
::= { ovtxCommon 1 }
ovtxCommonTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxCommonEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The table contains all modules of the OVTX-type in the NE"
::= { ovtxCommon 2 }
-- table of states entry(ro/rw)
ovtxCommonEntry OBJECT-TYPE
SYNTAX OvtxCommonEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Common-Values for a module."
INDEX { ovtxNESlot }
::= { ovtxCommonTable 1 }
-- the structure of the entry
OvtxCommonEntry ::= SEQUENCE
{
ovtxNESlot NESlotValue,
ovtxCommonType DisplayString,
ovtxCommonDescr DisplayString,
ovtxCommonFirmwareId DisplayString,
ovtxCommonModuleWidth ModuleWidthValue
}
ovtxNESlot OBJECT-TYPE
SYNTAX NESlotValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the chassis for which this
entry contains management information.
Equal to: modOVTXv11UniqueID"
::= { ovtxCommonEntry 1 }
ovtxCommonType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of physical module. modSlotEmpty indicates
an empty slot. A Value of modSlotUnknown indicates
that the type of module is unknown."
::= { ovtxCommonEntry 2 }
ovtxCommonDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A textual description of the module.
If not available, this Value should be
set to a zero length string."
::= { ovtxCommonEntry 3 }
ovtxCommonFirmwareId OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION "The firmware Id of the module."
::= { ovtxCommonEntry 4 }
ovtxCommonModuleWidth OBJECT-TYPE
SYNTAX ModuleWidthValue
ACCESS read-only
STATUS optional
DESCRIPTION "The width of the module in multiples of slots (1, 2, ...)"
::= { ovtxCommonEntry 5 }
--*****************************************************************************************
-- ovtxMeasuringValues group
-- table of measuring Values
ovtxMeasuringValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxMeasuringValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { ovtxMeasuringValues 1 }
-- table of measuring Values entry
ovtxMeasuringValuesEntry OBJECT-TYPE
SYNTAX OvtxMeasuringValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Common-Values for a module."
INDEX { ovtxNESlot }
::= { ovtxMeasuringValuesTable 1 }
-- the structure of the entry
OvtxMeasuringValuesEntry ::= SEQUENCE
{
ovtxOmiMeasuredLoLo INTEGER,
ovtxOmiMeasuredLo INTEGER,
ovtxOmiMeasuredValue INTEGER,
ovtxOmiMeasuredHi INTEGER,
ovtxOmiMeasuredHiHi INTEGER,
ovtxRfGainMeasuredLoLo INTEGER,
ovtxRfGainMeasuredLo INTEGER,
ovtxRfGainMeasuredValue INTEGER,
ovtxRfGainMeasuredHi INTEGER,
ovtxRfGainMeasuredHiHi INTEGER,
ovtxLaserCurrentRelLoLo INTEGER,
ovtxLaserCurrentRelLo INTEGER,
ovtxLaserCurrentRelValue INTEGER,
ovtxLaserCurrentRelHi INTEGER,
ovtxLaserCurrentRelHiHi INTEGER,
ovtxTecCurrentRelLoLo INTEGER,
ovtxTecCurrentRelLo INTEGER,
ovtxTecCurrentRelValue INTEGER,
ovtxTecCurrentRelHi INTEGER,
ovtxTecCurrentRelHiHi INTEGER,
ovtxOutputPowerLoLo INTEGER,
ovtxOutputPowerLo INTEGER,
ovtxOutputPowerValue INTEGER,
ovtxOutputPowerHi INTEGER,
ovtxOutputPowerHiHi INTEGER,
ovtxPlus3p3VLoLo INTEGER,
ovtxPlus3p3VLo INTEGER,
ovtxPlus3p3VValue INTEGER,
ovtxPlus3p3VHi INTEGER,
ovtxPlus3p3VHiHi INTEGER,
ovtxPlus5VLoLo INTEGER,
ovtxPlus5VLo INTEGER,
ovtxPlus5VValue INTEGER,
ovtxPlus5VHi INTEGER,
ovtxPlus5VHiHi INTEGER,
ovtxPlus12VLoLo INTEGER,
ovtxPlus12VLo INTEGER,
ovtxPlus12VValue INTEGER,
ovtxPlus12VHi INTEGER,
ovtxPlus12VHiHi INTEGER,
ovtxPlus24VLoLo INTEGER,
ovtxPlus24VLo INTEGER,
ovtxPlus24VValue INTEGER,
ovtxPlus24VHi INTEGER,
ovtxPlus24VHiHi INTEGER,
ovtxMinus5VLoLo INTEGER,
ovtxMinus5VLo INTEGER,
ovtxMinus5VValue INTEGER,
ovtxMinus5VHi INTEGER,
ovtxMinus5VHiHi INTEGER,
ovtxMinus12VLoLo INTEGER,
ovtxMinus12VLo INTEGER,
ovtxMinus12VValue INTEGER,
ovtxMinus12VHi INTEGER,
ovtxMinus12VHiHi INTEGER,
ovtxTemperatureLoLo INTEGER,
ovtxTemperatureLo INTEGER,
ovtxTemperatureValue INTEGER,
ovtxTemperatureHi INTEGER,
ovtxTemperatureHiHi INTEGER,
ovtxRfInputLoLo INTEGER,
ovtxRfInputLo INTEGER,
ovtxRfInputValue INTEGER,
ovtxRfInputHi INTEGER,
ovtxRfInputHiHi INTEGER,
ovtxSatRfInputLoLo INTEGER,
ovtxSatRfInputLo INTEGER,
ovtxSatRfInputValue INTEGER,
ovtxSatRfInputHi INTEGER,
ovtxSatRfInputHiHi INTEGER,
ovtxSatOmiMeasuredLoLo INTEGER,
ovtxSatOmiMeasuredLo INTEGER,
ovtxSatOmiMeasuredValue INTEGER,
ovtxSatOmiMeasuredHi INTEGER,
ovtxSatOmiMeasuredHiHi INTEGER,
ovtxSatRfGainMeasuredLoLo INTEGER,
ovtxSatRfGainMeasuredLo INTEGER,
ovtxSatRfGainMeasuredValue INTEGER,
ovtxSatRfGainMeasuredHi INTEGER,
ovtxSatRfGainMeasuredHiHi INTEGER
}
-- *****
ovtxOmiMeasuredLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset low alarm threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 1 }
ovtxOmiMeasuredLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset low warning threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 2 }
ovtxOmiMeasuredValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The offset from nominal OMI in steps of 0.1dB (CATV input).
If AGC is on this parameter is equal to ovtxConfigurationOmi.
If AGC is off this paramters shows the Measured-OMI for the adjusted gain."
::= { ovtxMeasuringValuesEntry 3 }
ovtxOmiMeasuredHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset high warning threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 4 }
ovtxOmiMeasuredHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset high alarm threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 5 }
-- *****
ovtxRfGainMeasuredLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset low alarm threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 6 }
ovtxRfGainMeasuredLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset low warning threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 7 }
ovtxRfGainMeasuredValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The offset from nominal gain in steps of 0.1dB (CATV input).
If AGC is off this parameter is equal to ovtxConfigurationRfGain.
If AGC is on this paramters shows the Measured-Rf-Gain for the adjusted omi."
::= { ovtxMeasuringValuesEntry 8 }
ovtxRfGainMeasuredHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset high warning threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 9 }
ovtxRfGainMeasuredHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset high alarm threshold in steps of 0.1dB (CATV input)."
::= { ovtxMeasuringValuesEntry 10 }
-- *****
ovtxLaserCurrentRelLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Relative laser current low alarm threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 11 }
ovtxLaserCurrentRelLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Relative laser current low warning threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 12 }
ovtxLaserCurrentRelValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The laser current relative to the current at begin of life in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 13 }
ovtxLaserCurrentRelHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Relative laser current high warning threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 14 }
ovtxLaserCurrentRelHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Relative laser current high alarm threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 15 }
-- *****
ovtxTecCurrentRelLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Thermo-electric-cooler current low alarm threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 16 }
ovtxTecCurrentRelLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Thermo-electric-cooler current low warning threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 17 }
ovtxTecCurrentRelValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The thermo-electric-cooler current relative to
its absolute high alarm threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 18 }
ovtxTecCurrentRelHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Thermo-electric-cooler current high warning threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 19 }
ovtxTecCurrentRelHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Thermo-electric-cooler current high alarm threshold in steps of 0.1%."
::= { ovtxMeasuringValuesEntry 20 }
-- *****
ovtxOutputPowerLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Output power low alarm threshold in steps of 0.1dBm."
::= { ovtxMeasuringValuesEntry 21 }
ovtxOutputPowerLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Output power low warning threshold in steps of 0.1dBm."
::= { ovtxMeasuringValuesEntry 22 }
ovtxOutputPowerValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Output power in steps of 0.1dBm."
::= { ovtxMeasuringValuesEntry 23 }
ovtxOutputPowerHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Output power high warning threshold in steps of 0.1dBm."
::= { ovtxMeasuringValuesEntry 24 }
ovtxOutputPowerHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Output power high alarm threshold in steps of 0.1dBm."
::= { ovtxMeasuringValuesEntry 25 }
-- *****
ovtxPlus3p3VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +3.3V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 26 }
ovtxPlus3p3VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +3.3V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 27 }
ovtxPlus3p3VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +3.3V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 28 }
ovtxPlus3p3VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +3.3V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 29 }
ovtxPlus3p3VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +3.3V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 30 }
-- *****
ovtxPlus5VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +5V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 31 }
ovtxPlus5VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +5V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 32 }
ovtxPlus5VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +5V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 33 }
ovtxPlus5VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +5V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 34 }
ovtxPlus5VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +5V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 35 }
-- *****
ovtxPlus12VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +12V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 36 }
ovtxPlus12VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +12V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 37 }
ovtxPlus12VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +12V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 38 }
ovtxPlus12VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +12V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 39 }
ovtxPlus12VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +12V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 40 }
-- *****
ovtxPlus24VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +24V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 41 }
ovtxPlus24VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +24V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 42 }
ovtxPlus24VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +24V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 43 }
ovtxPlus24VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +24V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 44 }
ovtxPlus24VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The +24V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 45 }
-- *****
ovtxMinus5VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -5V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 46 }
ovtxMinus5VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -5V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 47 }
ovtxMinus5VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -5V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 48 }
ovtxMinus5VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -5V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 49 }
ovtxMinus5VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -5V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 50 }
-- *****
ovtxMinus12VLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -12V supply voltage low alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 51 }
ovtxMinus12VLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -12V supply voltage low warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 52 }
ovtxMinus12VValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -12V supply voltage in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 53 }
ovtxMinus12VHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -12V supply voltage high warning threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 54 }
ovtxMinus12VHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The -12V supply voltage high alarm threshold in steps of 0.1V."
::= { ovtxMeasuringValuesEntry 55 }
-- *****
ovtxTemperatureLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The module temperature low alarm threshold in steps of 0.1 celsius degrees."
::= { ovtxMeasuringValuesEntry 56 }
ovtxTemperatureLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The module temperature low warning threshold in steps of 0.1 celsius degrees."
::= { ovtxMeasuringValuesEntry 57 }
ovtxTemperatureValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The module temperature in steps of 0.1 celsius degrees."
::= { ovtxMeasuringValuesEntry 58 }
ovtxTemperatureHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The module temperature high warning threshold in steps of 0.1 celsius degrees."
::= { ovtxMeasuringValuesEntry 59 }
ovtxTemperatureHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The module temperature high alarm threshold in steps of 0.1 celsius degrees."
::= { ovtxMeasuringValuesEntry 60 }
-- *****
ovtxRfInputLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) low alarm threshold in steps of 0.1 dBm (CATV input)."
::= { ovtxMeasuringValuesEntry 61 }
ovtxRfInputLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) low warning threshold in steps of 0.1 dBm (CATV input)."
::= { ovtxMeasuringValuesEntry 62 }
ovtxRfInputValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "RfInput (total rms) in steps of 0.1 dBm (CATV input)."
::= { ovtxMeasuringValuesEntry 63 }
ovtxRfInputHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) high warning threshold in steps of 0.1 dBm (CATV input)."
::= { ovtxMeasuringValuesEntry 64 }
ovtxRfInputHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) high alarm threshold in steps of 0.1 dBm (CATV input)."
::= { ovtxMeasuringValuesEntry 65 }
-- *****
ovtxSatRfInputLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) low alarm threshold in steps of 0.1 dBm (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 66 }
ovtxSatRfInputLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) low warning threshold in steps of 0.1 dBm (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 67 }
ovtxSatRfInputValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "RfInput (total rms) in steps of 0.1 dBm (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 68 }
ovtxSatRfInputHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) high warning threshold in steps of 0.1 dBm (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 69 }
ovtxSatRfInputHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "RfInput (total rms) high alarm threshold in steps of 0.1 dBm (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 70 }
-- *****
ovtxSatOmiMeasuredLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset low alarm threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 71 }
ovtxSatOmiMeasuredLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset low warning threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 72 }
ovtxSatOmiMeasuredValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The offset from nominal OMI in steps of 0.1dB (SAT input).
If SAT AGC is on this parameter is equal to ovtxConfigurationSatOmi.
If SAT AGC is off this paramters shows the measured-OMI for the adjusted gain.
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 73 }
ovtxSatOmiMeasuredHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset high warning threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 74 }
ovtxSatOmiMeasuredHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-OMI offset high alarm threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 75 }
-- *****
ovtxSatRfGainMeasuredLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset low alarm threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 76 }
ovtxSatRfGainMeasuredLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset low warning threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 77 }
ovtxSatRfGainMeasuredValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The offset from nominal gain in steps of 0.1dB (SAT input).
If AGC is off this parameter is equal to ovtxConfigurationSatRfGain.
If AGC is on this paramters shows the measured-Rf-Gain for the adjusted omi.
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 78 }
ovtxSatRfGainMeasuredHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset high warning threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 79 }
ovtxSatRfGainMeasuredHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Measured-Rf-Gain offset high alarm threshold in steps of 0.1dB (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero."
::= { ovtxMeasuringValuesEntry 80 }
--*****************************************************************************************
-- ovtxStates group
-- Note: For every control OId there must be a correspondant alarm OId!
ovtxStatesTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxStatesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { ovtxStates 1 }
-- table of states entry(ro/rw)
ovtxStatesEntry OBJECT-TYPE
SYNTAX OvtxStatesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Alarms for a module."
INDEX { ovtxNESlot }
::= { ovtxStatesTable 1 }
-- the structure of the entry
OvtxStatesEntry ::= SEQUENCE
{
ovtxStatesOutputLow PerceivedSeverityValue,
ovtxStatesOutputHigh PerceivedSeverityValue,
ovtxStatesInputLow PerceivedSeverityValue,
ovtxStatesLaserAging PerceivedSeverityValue,
ovtxStatesTecHigh PerceivedSeverityValue,
ovtxStatesLaserTempLow PerceivedSeverityValue,
ovtxStatesLaserTempHigh PerceivedSeverityValue,
ovtxStatesOmiOrRfgainLow PerceivedSeverityValue,
ovtxStatesOmiOrRfgainHigh PerceivedSeverityValue,
ovtxStatesPowerSupplyLeft PerceivedSeverityValue,
ovtxStatesPowerSupplyRight PerceivedSeverityValue,
ovtxStatesFanLeft PerceivedSeverityValue,
ovtxStatesFanRight PerceivedSeverityValue,
ovtxStatesTemperatureLow PerceivedSeverityValue,
ovtxStatesTemperatureHigh PerceivedSeverityValue,
ovtxStatesPlus3p3VLow PerceivedSeverityValue,
ovtxStatesPlus3p3VHigh PerceivedSeverityValue,
ovtxStatesPlus5VLow PerceivedSeverityValue,
ovtxStatesPlus5VHigh PerceivedSeverityValue,
ovtxStatesPlus12VLow PerceivedSeverityValue,
ovtxStatesPlus12VHigh PerceivedSeverityValue,
ovtxStatesPlus24VLow PerceivedSeverityValue,
ovtxStatesPlus24VHigh PerceivedSeverityValue,
ovtxStatesMinus5VLow PerceivedSeverityValue,
ovtxStatesMinus5VHigh PerceivedSeverityValue,
ovtxStatesMinus12VLow PerceivedSeverityValue,
ovtxStatesMinus12VHigh PerceivedSeverityValue,
ovtxStatesLaserShutdown PerceivedSeverityValue,
ovtxStatesInitializing PerceivedSeverityValue,
ovtxStatesBootloader PerceivedSeverityValue,
ovtxStatesCommLoss PerceivedSeverityValue,
ovtxStatesInputHigh PerceivedSeverityValue,
ovtxStatesRedundancySwitch PerceivedSeverityValue,
ovtxStatesSatInputLow PerceivedSeverityValue,
ovtxStatesSatInputHigh PerceivedSeverityValue,
ovtxStatesSatOmiOrRfgainLow PerceivedSeverityValue,
ovtxStatesSatOmiOrRfgainHigh PerceivedSeverityValue,
ovtxStatesSatLnbShortCircuit PerceivedSeverityValue,
ovtxStatesSbs1Level PerceivedSeverityValue,
ovtxStatesSbs2Level PerceivedSeverityValue,
ovtxStatesSbs1PllNotLocked PerceivedSeverityValue,
ovtxStatesSbs2PllNotLocked PerceivedSeverityValue,
ovtxStatesInternalAlarm PerceivedSeverityValue
}
ovtxStatesOutputLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Optical output power low"
::= { ovtxStatesEntry 1 }
ovtxStatesOutputHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Optical output power high"
::= { ovtxStatesEntry 2 }
ovtxStatesInputLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "RF input power low (CATV input)"
::= { ovtxStatesEntry 3 }
ovtxStatesLaserAging OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The laser is aging"
::= { ovtxStatesEntry 4 }
ovtxStatesTecHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Laser cooler limit reached"
::= { ovtxStatesEntry 5 }
ovtxStatesLaserTempLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Laser temperature low"
::= { ovtxStatesEntry 6 }
ovtxStatesLaserTempHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Laser temperature high"
::= { ovtxStatesEntry 7 }
ovtxStatesOmiOrRfgainLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Omi or rf-gain (depending on mode) low (CATV input)"
::= { ovtxStatesEntry 8 }
ovtxStatesOmiOrRfgainHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Omi or rf-gain (depending on mode) high (CATV input)"
::= { ovtxStatesEntry 9 }
ovtxStatesPowerSupplyLeft OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The left (looking from front) power supply unit fails"
::= { ovtxStatesEntry 10 }
ovtxStatesPowerSupplyRight OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The right (looking from front) power supply unit fails"
::= { ovtxStatesEntry 11 }
ovtxStatesFanLeft OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The left (looking from front) fan unit fails"
::= { ovtxStatesEntry 12 }
ovtxStatesFanRight OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The right (looking from front) fan unit fails"
::= { ovtxStatesEntry 13 }
ovtxStatesTemperatureLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Device internal temperature low"
::= { ovtxStatesEntry 14 }
ovtxStatesTemperatureHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Device internal temperature high"
::= { ovtxStatesEntry 15 }
ovtxStatesPlus3p3VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "3.3 Volt supply low"
::= { ovtxStatesEntry 16 }
ovtxStatesPlus3p3VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "3.3 Volt supply high"
::= { ovtxStatesEntry 17 }
ovtxStatesPlus5VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "5 Volt supply low"
::= { ovtxStatesEntry 18 }
ovtxStatesPlus5VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "5 Volt supply high"
::= { ovtxStatesEntry 19 }
ovtxStatesPlus12VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "12 Volt supply low"
::= { ovtxStatesEntry 20 }
ovtxStatesPlus12VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "12 Volt supply high"
::= { ovtxStatesEntry 21 }
ovtxStatesPlus24VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "24 Volt supply low"
::= { ovtxStatesEntry 22 }
ovtxStatesPlus24VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "24 Volt supply high"
::= { ovtxStatesEntry 23 }
ovtxStatesMinus5VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "-5 Volt supply low"
::= { ovtxStatesEntry 24 }
ovtxStatesMinus5VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "-5 Volt supply high"
::= { ovtxStatesEntry 25 }
ovtxStatesMinus12VLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "-12 Volt supply low"
::= { ovtxStatesEntry 26 }
ovtxStatesMinus12VHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "-12 Volt supply high"
::= { ovtxStatesEntry 27 }
ovtxStatesLaserShutdown OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Laser is shutdown, no optical output"
::= { ovtxStatesEntry 28 }
ovtxStatesInitializing OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "The device is initializing"
::= { ovtxStatesEntry 29 }
ovtxStatesBootloader OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device is running in bootloader mode
without a legal application software."
::= { ovtxStatesEntry 30 }
ovtxStatesCommLoss OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NEC has lost the connection to the device.
Reason may be a removed or defective device.
Note that this state is set by the NEC and not
by the device"
::= { ovtxStatesEntry 31 }
ovtxStatesInputHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "RF input power high (CATV input)"
::= { ovtxStatesEntry 32 }
ovtxStatesRedundancySwitch OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "This (redundant) device has been activated (redundancy switchover)"
::= { ovtxStatesEntry 33 }
ovtxStatesSatInputLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "RF input power low (SAT input)
Only used if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 34 }
ovtxStatesSatInputHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "RF input power high (SAT input)
Only used if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 35 }
ovtxStatesSatOmiOrRfgainLow OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Omi or rf-gain (depending on mode) low (SAT input)
Only used if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 36 }
ovtxStatesSatOmiOrRfgainHigh OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Omi or rf-gain (depending on mode) high (SAT input)
Only used if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 37 }
ovtxStatesSatLnbShortCircuit OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Short-circuit at SAT LNB
Only used if ovtxDisplaySatLnbSupplySupported != notSupported(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 38 }
ovtxStatesSbs1Level OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "SBS #1 level alarm
Only used if ovtxDisplaySbsExtensionsSupported == true(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 39 }
ovtxStatesSbs2Level OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "SBS #2 level alarm
Only used if ovtxDisplaySbsExtensionsSupported == true(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 40 }
ovtxStatesSbs1PllNotLocked OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "SBS #1 PLL not locked
Only used if ovtxDisplaySbsExtensionsSupported == true(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 41 }
ovtxStatesSbs2PllNotLocked OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "SBS #2 PLL not locked
Only used if ovtxDisplaySbsExtensionsSupported == true(1),
otherwise always reports clear(5)."
::= { ovtxStatesEntry 42 }
ovtxStatesInternalAlarm OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Internal hardware failure"
::= { ovtxStatesEntry 43 }
--*****************************************************************************************
-- ovtxControl group
ovtxControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { ovtxControl 1 }
-- table of control entry(ro/rw)
ovtxControlEntry OBJECT-TYPE
SYNTAX OvtxControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Alarms for a module."
INDEX { ovtxNESlot }
::= { ovtxControlTable 1 }
-- the structure of the entry
OvtxControlEntry ::= SEQUENCE
{
ovtxControlLaserOutputMode LaserOutputMode,
ovtxControlReset TruthValue,
ovtxControlModuleLedBlink TruthValue
}
ovtxControlLaserOutputMode OBJECT-TYPE
SYNTAX LaserOutputMode
ACCESS read-write
STATUS mandatory
DESCRIPTION "The output mode of the laser.
NOTE: The error mask used for parameter 'laserShutdownOnMaskedError(3)'
is the same mask used for external IO port, 'ovtxConfigurationRedundancyMask'"
::= { ovtxControlEntry 1 }
ovtxControlReset OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION "Reset the module."
::= { ovtxControlEntry 2 }
ovtxControlModuleLedBlink OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION "Writing this variable to true(1) lets the device's
modul LED blink green for 10 seconds.
Writing this variable to false(2) stops blinking at once.
This variable always returns false(2) on read requests"
::= { ovtxControlEntry 3 }
--*****************************************************************************************
-- ovtxConfiguration group
ovtxConfigurationTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxConfigurationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { ovtxConfiguration 1 }
-- table of configuration entry(ro/rw)
ovtxConfigurationEntry OBJECT-TYPE
SYNTAX OvtxConfigurationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { ovtxNESlot }
::= { ovtxConfigurationTable 1 }
-- the structure of the entry
OvtxConfigurationEntry ::= SEQUENCE
{
ovtxConfigurationNESlotWrite NESlotWriteValue,
ovtxConfigurationModeAGC AGCmode,
ovtxConfigurationOmi INTEGER,
ovtxConfigurationRfGain INTEGER,
ovtxConfigurationSbsSuppression INTEGER,
ovtxConfigurationChannelDistance INTEGER,
ovtxConfigurationLaserFrequency INTEGER,
ovtxConfigurationRfInputLimitLoLo INTEGER,
ovtxConfigurationRfInputLimitLo INTEGER,
ovtxConfigurationRfInputLimitHi INTEGER,
ovtxConfigurationRfInputLimitHiHi INTEGER,
ovtxConfigurationRfGainMeasuredLimitLoLo INTEGER,
ovtxConfigurationRfGainMeasuredLimitLo INTEGER,
ovtxConfigurationRfGainMeasuredLimitHi INTEGER,
ovtxConfigurationRfGainMeasuredLimitHiHi INTEGER,
ovtxConfigurationOmiMeasuredLimitLoLo INTEGER,
ovtxConfigurationOmiMeasuredLimitLo INTEGER,
ovtxConfigurationOmiMeasuredLimitHi INTEGER,
ovtxConfigurationOmiMeasuredLimitHiHi INTEGER,
ovtxConfigurationOutputPwrLimitLoLo INTEGER,
ovtxConfigurationOutputPwrLimitLo INTEGER,
ovtxConfigurationOutputPwrLimitHi INTEGER,
ovtxConfigurationOutputPwrLimitHiHi INTEGER,
ovtxConfigurationRedundancyMode RedundancyMode,
ovtxConfigurationRedundancyMask RedundancyMask,
ovtxConfigurationCsoRegulationMode CsoRegulationMode,
ovtxConfigurationSlope INTEGER,
ovtxConfigurationFiberLength INTEGER,
ovtxConfigurationSatModeAGC SatAGCmode,
ovtxConfigurationSatOmi INTEGER,
ovtxConfigurationSatRfGain INTEGER,
ovtxConfigurationSatSlope INTEGER,
ovtxConfigurationRfInputAlarmMode RfInputAlarmMode,
ovtxConfigurationSatLnbSupply LnbSupplyValue,
ovtxConfigurationSbsSuppressionMode SbsSuppressionModeValue,
ovtxConfigurationSbsFiberType SbsFiberTypeValue,
ovtxConfigurationSbsFiberLength SbsFiberLengthValue
}
ovtxConfigurationNESlotWrite OBJECT-TYPE
SYNTAX NESlotWriteValue
ACCESS read-write
STATUS optional
DESCRIPTION "By writing this variable a slot can be assigned
for devices that dont support hardware slot detection.
Reading '-1' means that the slot position is NOT writable."
::= { ovtxConfigurationEntry 1 }
ovtxConfigurationModeAGC OBJECT-TYPE
SYNTAX AGCmode
ACCESS read-write
STATUS mandatory
DESCRIPTION "The AGC mode of the optical transmitter (CATV input)."
::= { ovtxConfigurationEntry 2 }
ovtxConfigurationOmi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The desired offset from nominal OMI in 0.1dB units (CATV input).
This parameter is only used if AGC is on."
::= { ovtxConfigurationEntry 3 }
ovtxConfigurationRfGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The desired offset from nominal gain in 0.1dB units (CATV input).
This parameter is only used if AGC is off."
::= { ovtxConfigurationEntry 4 }
ovtxConfigurationSbsSuppression OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sbs suppression in 0.1dBm units."
::= { ovtxConfigurationEntry 5 }
ovtxConfigurationChannelDistance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The channel raster in MHz units."
::= { ovtxConfigurationEntry 6 }
ovtxConfigurationLaserFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The laser frequency in GHz units."
::= { ovtxConfigurationEntry 7 }
-- *****
ovtxConfigurationRfInputLimitLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rf input power low alarm limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 8 }
ovtxConfigurationRfInputLimitLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rf input power low warning limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 9 }
ovtxConfigurationRfInputLimitHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rf input power high warning limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 10 }
ovtxConfigurationRfInputLimitHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rf input power high alarm limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 11 }
-- *****
ovtxConfigurationRfGainMeasuredLimitLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-Rf-Gain offset low alarm limit in 0.1 dB units (in AGC ON mode)"
::={ ovtxConfigurationEntry 12 }
ovtxConfigurationRfGainMeasuredLimitLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-Rf-Gain offset low warning limit in 0.1 dB units (in AGC ON mode)"
::={ ovtxConfigurationEntry 13 }
ovtxConfigurationRfGainMeasuredLimitHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-Rf-Gain offset high warning limit in 0.1 dB units (in AGC ON mode)"
::={ ovtxConfigurationEntry 14 }
ovtxConfigurationRfGainMeasuredLimitHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-Rf-Gain offset high alarm limit in 0.1 dB units (in AGC ON mode)"
::={ ovtxConfigurationEntry 15 }
-- *****
ovtxConfigurationOmiMeasuredLimitLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-OMI offset low alarm limit in 0.1 dB units (in AGC OFF mode)"
::={ ovtxConfigurationEntry 16 }
ovtxConfigurationOmiMeasuredLimitLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-OMI offset low warning limit in 0.1 dB units(in AGC OFF mode)"
::={ ovtxConfigurationEntry 17 }
ovtxConfigurationOmiMeasuredLimitHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-OMI offset high warning limit in 0.1 dB units(in AGC OFF mode)"
::={ ovtxConfigurationEntry 18 }
ovtxConfigurationOmiMeasuredLimitHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Measured-OMI offset high alarm limit in 0.1 dB units(in AGC OFF mode)"
::={ ovtxConfigurationEntry 19 }
-- *****
ovtxConfigurationOutputPwrLimitLoLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The output power low alarm limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 20 }
ovtxConfigurationOutputPwrLimitLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The output power low warning limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 21 }
ovtxConfigurationOutputPwrLimitHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The output power high warning limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 22 }
ovtxConfigurationOutputPwrLimitHiHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The output power high alarm limit in 0.1 dBm units"
::={ ovtxConfigurationEntry 23 }
-- *****
ovtxConfigurationRedundancyMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS read-write
STATUS mandatory
DESCRIPTION "The device's redundancy mode."
::= { ovtxConfigurationEntry 24 }
ovtxConfigurationRedundancyMask OBJECT-TYPE
SYNTAX RedundancyMask
ACCESS read-write
STATUS mandatory
DESCRIPTION "The device's redundancy mask setings."
::= { ovtxConfigurationEntry 25 }
-- *****
ovtxConfigurationCsoRegulationMode OBJECT-TYPE
SYNTAX CsoRegulationMode
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The desired CSO regulation mode of the optical transmitter.
Only usable if ovtxDisplayExtendedCapabilities == true(1),
otherwise always reports csoRegModeChannelControlled(1)"
::= { ovtxConfigurationEntry 26 }
ovtxConfigurationSlope OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The desired slope in 0.1 dB units (CATV input).
Only usable if ovtxDisplayExtendedCapabilities == true(1),
otherwise always reports zero"
::= { ovtxConfigurationEntry 27 }
ovtxConfigurationFiberLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The optical fiber length in meter units.
Only usable if ovtxDisplayExtendedCapabilities == true(1),
otherwise always reports zero"
::= { ovtxConfigurationEntry 28 }
ovtxConfigurationSatModeAGC OBJECT-TYPE
SYNTAX SatAGCmode
ACCESS read-write
STATUS mandatory
DESCRIPTION "The AGC mode of the optical transmitter (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports satAgcOff(1)"
::= { ovtxConfigurationEntry 29 }
ovtxConfigurationSatOmi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The desired offset from nominal OMI in 0.1dB units (SAT input).
This parameter is only used if AGC is on.
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero"
::= { ovtxConfigurationEntry 30 }
ovtxConfigurationSatRfGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The desired offset from nominal gain in 0.1dB units (SAT input).
This parameter is only used if AGC is off.
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero"
::= { ovtxConfigurationEntry 31 }
ovtxConfigurationSatSlope OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The desired slope in 0.1 dB units (SAT input).
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero"
::= { ovtxConfigurationEntry 32 }
ovtxConfigurationRfInputAlarmMode OBJECT-TYPE
SYNTAX RfInputAlarmMode
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The RF input alarm mode (Can be used to disable alarms of unused RF inputs)
Only usable if ovtxDisplayRfInputCapabilities == rfInputCatvAndSatSupported(3),
otherwise always reports alarmEnableAll(1)"
::= { ovtxConfigurationEntry 33 }
ovtxConfigurationSatLnbSupply OBJECT-TYPE
SYNTAX LnbSupplyValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SAT LNB supply control.
This feature is not supported by all transmitter devices,
see ovtxDisplaySatLnbSupplySupported"
::= { ovtxConfigurationEntry 34 }
ovtxConfigurationSbsSuppressionMode OBJECT-TYPE
SYNTAX SbsSuppressionModeValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SBS suppression mode.
This feature is not supported by all transmitter devices,
see ovtxDisplaySbsSuppressionModeSupported"
::= { ovtxConfigurationEntry 35 }
ovtxConfigurationSbsFiberType OBJECT-TYPE
SYNTAX SbsFiberTypeValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SBS fiber type.
This feature is not supported by all transmitter devices,
see ovtxDisplaySbsFiberParametersSupported"
::= { ovtxConfigurationEntry 36 }
ovtxConfigurationSbsFiberLength OBJECT-TYPE
SYNTAX SbsFiberLengthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SBS suppression mode.
This feature is not supported by all transmitter devices,
see ovtxDisplaySbsFiberParametersSupported"
::= { ovtxConfigurationEntry 37 }
--*****************************************************************************************
-- Display group
ovtxDisplayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OvtxDisplayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { ovtxDisplay 1 }
-- table of configuration entry(ro/rw)
ovtxDisplayEntry OBJECT-TYPE
SYNTAX OvtxDisplayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { ovtxNESlot }
::= { ovtxDisplayTable 1 }
-- the structure of the entry
OvtxDisplayEntry ::= SEQUENCE
{
ovtxDisplayRfInputValue INTEGER,
ovtxDisplayLaserFrequencyMin INTEGER,
ovtxDisplayLaserFrequencyMax INTEGER,
ovtxDisplayLaserFrequencyStep INTEGER,
ovtxDisplayOmiNominal INTEGER,
ovtxDisplaySatOmiNominal INTEGER,
ovtxDisplayRegulationState RegulationState,
ovtxDisplayExtendedCapabilities TruthValue,
ovtxDisplayRfInputCapabilities RfInputCapabilities,
ovtxDisplaySatLnbSupplySupported LnbSupplySupportedValue,
ovtxDisplaySbsExtensionsSupported TruthValue,
ovtxDisplaySbsSuppressionModeSupported TruthValue,
ovtxDisplaySbsFiberParametersSupported TruthValue
}
ovtxDisplayRfInputValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "RfInput (total rms) in steps of 0.1 dBm."
::= { ovtxDisplayEntry 1 }
-- *****
ovtxDisplayLaserFrequencyMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The minimum adjustable laser frequency in GHz units."
::={ ovtxDisplayEntry 2 }
ovtxDisplayLaserFrequencyMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The maximum adjustable laser frequency in GHz units."
::={ ovtxDisplayEntry 3 }
ovtxDisplayLaserFrequencyStep OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The supported laser frequency stepsize in GHz units."
::={ ovtxDisplayEntry 4 }
-- *****
ovtxDisplayOmiNominal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The nominal OMI in 0.1 percent units (CATV input)"
::={ ovtxDisplayEntry 5 }
-- *****
ovtxDisplaySatOmiNominal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The nominal OMI in 0.1 percent units (SAT input)
Only usable if ovtxDisplayRfInputCapabilities != rfInputCatvOnlySupported(1),
otherwise always reports zero"
::={ ovtxDisplayEntry 6 }
ovtxDisplayRegulationState OBJECT-TYPE
SYNTAX RegulationState
ACCESS read-only
STATUS mandatory
DESCRIPTION "The transmitters current regulation state
Only usable if ovtxDisplayExtendedCapabilities == true(1),
otherwise always reports regulationStateUnknownOrNotSupported(1)"
::={ ovtxDisplayEntry 7 }
ovtxDisplayExtendedCapabilities OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns true(1) if the transmitter supports the extended features
represented by the variables ovtxConfigurationCsoRegulationMode,
ovtxConfigurationSlope and ovtxConfigurationFiberLength"
::={ ovtxDisplayEntry 8 }
ovtxDisplayRfInputCapabilities OBJECT-TYPE
SYNTAX RfInputCapabilities
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns the transmitter supported RF input capabilities"
::={ ovtxDisplayEntry 9 }
ovtxDisplaySatLnbSupplySupported OBJECT-TYPE
SYNTAX LnbSupplySupportedValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Returns the supported SAT LNB supply features"
::={ ovtxDisplayEntry 10 }
-- *****
ovtxDisplaySbsExtensionsSupported OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Returns true(1) if the transmitter supports the extended SBS alarm features"
::={ ovtxDisplayEntry 11 }
ovtxDisplaySbsSuppressionModeSupported OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Returns true(1) if the transmitter supports the SbsSuppressionMode configuration feature"
::={ ovtxDisplayEntry 12 }
ovtxDisplaySbsFiberParametersSupported OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION "Returns true(1) if the transmitter supports the SbsFiber configuration feature"
::={ ovtxDisplayEntry 13 }
END