mibs/MIBS/brocade/FOUNDRY-SN-STACKING-MIB

436 lines
13 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
FOUNDRY-SN-STACKING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
snSwitch
FROM FOUNDRY-SN-SWITCH-GROUP-MIB
MacAddress
FROM SNMPv2-TC
DisplayString
FROM FOUNDRY-SN-AGENT-MIB
InterfaceIndexOrZero
FROM IF-MIB;
snStacking MODULE-IDENTITY
LAST-UPDATED "201006020000Z" -- 04 June 2010
ORGANIZATION "Brocade Communications Systems, Inc."
CONTACT-INFO
"Technical Support Center
130 Holger Way,
San Jose, CA 95134
Email: ipsupport@brocade.com
Phone: 1-800-752-8061
URL: www.brocade.com"
DESCRIPTION
"Management Information for stacking system
configuration and operational status.
Copyright 1996-2010 Brocade Communications Systems, Inc.
All rights reserved.
This Brocade Communications Systems SNMP Management Information Base Specification
embodies Brocade Communications Systems' confidential and proprietary
intellectual property. Brocade Communications Systems retains all
title and ownership in the Specification, including any revisions.
This Specification is supplied AS IS, and Brocade Communications Systems makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the specification, and any unintended
consequence it may on the user environment."
REVISION "201006020000Z" -- 04 June 2010
DESCRIPTION
"Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
REVISION "200805050000Z" -- May 5, 2008
DESCRIPTION
""
::= { snSwitch 31}
--
-- Stacking system
--
snStackingGlobalObjects OBJECT IDENTIFIER ::= { snStacking 1 }
snStackingTableObjects OBJECT IDENTIFIER ::= { snStacking 2 }
--
-- Stacking system Global Scalar Object Section
--
snStackingGlobalConfigState OBJECT-TYPE
SYNTAX INTEGER {
none(0),
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure stack state for stacking feature on the global level.
none: neutral, receive packets only
enable: stacking is enable, send and receive packets
disable: stacking is disable, No send and receive packets"
::= { snStackingGlobalObjects 1}
snStackingGlobalMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management MAC address of the stacking system.
This is available to change management MAC address of stack
for administrative purpose. It is strongly recommended that this
command should be used with upmost caution to prevent duplicate
MAC address and must reboot the system to take an effect.
It is mutually exclusive from enabling the persistent MAC timer.
Enter zero MAC address to remove the configured MAC address"
::= { snStackingGlobalObjects 2 }
snStackingGlobalPersistentMacTimerState OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure persistent MAC timer state for stacking feature on the global level.
enable: the persistent MAC timer is active and configured. The persistent MAC
timer is set as the default timer (60 minutes)
disable: deactivate the persistent MAC timer. It will stop the use of persistent MAC
address and use new active stack unit's base MAC address "
::= { snStackingGlobalObjects 3}
snStackingGlobalPersistentMacTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Persistent MAC timer in minutes for the stacking system
Number of minutes to retain original active stack unit's base MAC address in event of
active unit crash or removal. This timer is triggered when new active unit is elected.
When timer expires, new active unit will change stacking MAC to its own base MAC
address and advertise its own base MAC address to management VLAN to update the
ARP table of peers. If you decide to use new active unit's MAC address, one must enter
this timer again to reactivate the persistent MAC.
0 - keep it forever.
5 to 3600 - valid value range.
60 - default value."
::= { snStackingGlobalObjects 4 }
snStackingGlobalTopology OBJECT-TYPE
SYNTAX INTEGER {
other(1),
chain(2),
ring(3),
standalone(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The topology of the stacking system "
::= { snStackingGlobalObjects 5 }
--
-- Stacking system Table Object Section
--
--
-- Stacking configuration unit Table
-- Use this table to display and configure stacking related information for each unit
--
snStackingConfigUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingConfigUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stacking configuration unit table."
::= { snStackingTableObjects 1 }
snStackingConfigUnitEntry OBJECT-TYPE
SYNTAX SnStackingConfigUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the stacking configuration table."
INDEX { snStackingConfigUnitIndex }
::= { snStackingConfigUnitTable 1 }
SnStackingConfigUnitEntry ::= SEQUENCE {
snStackingConfigUnitIndex Integer32,
snStackingConfigUnitPriority Integer32,
snStackingConfigUnitConfigStackPort InterfaceIndexOrZero,
snStackingConfigUnitRowStatus INTEGER,
snStackingConfigUnitType DisplayString,
snStackingConfigUnitState INTEGER,
snStackingConfigUnitStackPort1 InterfaceIndexOrZero,
snStackingConfigUnitStackPort2 InterfaceIndexOrZero
}
snStackingConfigUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The stacking unit Id"
::= { snStackingConfigUnitEntry 1 }
snStackingConfigUnitPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority in Active/backup eclection."
::= { snStackingConfigUnitEntry 2 }
snStackingConfigUnitConfigStackPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IfIndex for the configured stacking port. If no
stacking port is configured, it will be displayed zero
and the first two 10G ports as the default stacking ports.
Enter zero to remove the configured stacking port. "
::= { snStackingConfigUnitEntry 3 }
snStackingConfigUnitRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3)
-- create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to delete row in the
table and control if they are used. The values that
can be written are:
delete(3)...deletes the row
If the row exists, then a SET with value of create(4)
returns error 'wrongValue'. Deleted rows go away immediately.
The following values can be returned on reads:
noSuchName...no such row
other(1).....some other cases
valid(2)....the row exists and is valid"
::= { snStackingConfigUnitEntry 4 }
snStackingConfigUnitType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the configured/active system type for each unit."
::= { snStackingConfigUnitEntry 5 }
snStackingConfigUnitState OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2),
reserved(3),
empty(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A state for each unit "
::= { snStackingConfigUnitEntry 6 }
snStackingConfigUnitStackPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingConfigUnitEntry 7 }
snStackingConfigUnitStackPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingConfigUnitEntry 8 }
--
-- Stacking operation unit Table
-- Use this table to display stacking related information for each operational unit
--
snStackingOperUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackingOperUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Stacking operation unit table."
::= { snStackingTableObjects 2 }
snStackingOperUnitEntry OBJECT-TYPE
SYNTAX SnStackingOperUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the stacking operation table."
INDEX { snStackingOperUnitIndex }
::= { snStackingOperUnitTable 1 }
SnStackingOperUnitEntry ::= SEQUENCE {
snStackingOperUnitIndex Integer32,
snStackingOperUnitRole INTEGER,
snStackingOperUnitMac MacAddress,
snStackingOperUnitPriority Integer32,
snStackingOperUnitState INTEGER,
snStackingOperUnitDescription DisplayString,
snStackingOperUnitStackPort1 InterfaceIndexOrZero,
snStackingOperUnitStackPort1State INTEGER,
snStackingOperUnitStackPort2 InterfaceIndexOrZero,
snStackingOperUnitStackPort2State INTEGER,
snStackingOperUnitNeighbor1 Integer32,
snStackingOperUnitNeighbor2 Integer32,
snStackingOperUnitImgVer DisplayString,
snStackingOperUnitBuildlVer DisplayString
}
snStackingOperUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The stacking unit Id"
::= { snStackingOperUnitEntry 1 }
snStackingOperUnitRole OBJECT-TYPE
SYNTAX INTEGER {
other(1),
active(2),
standby(3),
member(4),
standalone(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A role for each unit "
::= { snStackingOperUnitEntry 2 }
snStackingOperUnitMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A MAC address for each unit"
::= { snStackingOperUnitEntry 3 }
snStackingOperUnitPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority in Active/backup eclection."
::= { snStackingOperUnitEntry 4 }
snStackingOperUnitState OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2),
reserved(3),
empty(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A state for each unit "
::= { snStackingOperUnitEntry 5}
snStackingOperUnitDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the stacking state for each unit."
::= { snStackingOperUnitEntry 6 }
snStackingOperUnitStackPort1 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingOperUnitEntry 7 }
snStackingOperUnitStackPort1State OBJECT-TYPE
SYNTAX INTEGER {
other(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first stack port state for each unit. "
::= { snStackingOperUnitEntry 8 }
snStackingOperUnitStackPort2 OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second stack port for each unit. It returns 0 if stack port does not exist."
::= { snStackingOperUnitEntry 9 }
snStackingOperUnitStackPort2State OBJECT-TYPE
SYNTAX INTEGER {
other(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second stack port state for each unit. "
::= { snStackingOperUnitEntry 10 }
snStackingOperUnitNeighbor1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stacking neighbor unit (left) number.
If there is no neighbor unit, then it returns 0."
::= { snStackingOperUnitEntry 11 }
snStackingOperUnitNeighbor2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stacking neighbor unit (left) number.
If there is no neighbor unit, then it returns 0."
::= { snStackingOperUnitEntry 12 }
snStackingOperUnitImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the running software image"
::= { snStackingOperUnitEntry 13 }
snStackingOperUnitBuildlVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the running software build"
::= { snStackingOperUnitEntry 14 }
END