-- Title: Switch System MIB.
--
SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC
Integer32, OBJECT-TYPE, OBJECT-IDENTITY,
MODULE-IDENTITY
FROM SNMPv2-SMI
SwSensorIndex, SwPortIndex
FROM Brocade-TC
sw
FROM SWBASE-MIB;
swSystem MODULE-IDENTITY
LAST-UPDATED "1104151830Z" -- Apr 15, 20i11 6:30pm
ORGANIZATION "Brocade Communications Systems, Inc.,"
CONTACT-INFO "Customer Support Group
Brocade Communications Systems,
130 Holger Way,
San Jose, CA 95134 U.S.A
Tel: +1-408-333-8000
Fax: +1-408-333-8101
Email: support@Brocade.COM
WEB: www.brocade.com"
DESCRIPTION "The MIB module is for system information.
Copyright (c) 1996-2003 Brocade Communications Systems, Inc.
All rights reserved."
REVISION "1104151830Z" -- Apr 15, 2011 6:30pm
DESCRIPTION "Initial version of this module."
REVISION "1204301800Z" -- Apr 30, 2012 6:00pm
DESCRIPTION "Added swID mib object."
::= { sw 1 }
swFabric OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for swFabric group."
::= { sw 2 }
-- 3..7 are reserved; should not be used for new features.
swFCport OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for swFCport group."
::= { sw 6 }
swEvent OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for swEvent group."
::= { sw 8 }
FcPortFlag ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the port status for a FC Flag. Currently this will indicate
if the port is virtual or physical."
SYNTAX BITS {
physical (0),
virtual (1)
}
-- Fabric member information
--
swVfId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Virtual fabric id."
::= { swFabric 15 }
-- End of Fabric member information
--
--
-- the System Group (sw)
--
swCurrentDate OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current date information in displayable textual
format."
::= { swSystem 1 }
swBootDate OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date and time when the system last booted, in
displayable textual format."
::= { swSystem 2 }
swFWLastUpdated OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The information indicates the date when the firmware
was last updated, in displayable textual format."
::= { swSystem 3 }
swFlashLastUpdated OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The information indicates the date when the FLASH
was last updated, in displayable textual format."
::= { swSystem 4 }
swBootPromLastUpdated OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The information indicates the date when the boot PROM
was last updated, in displayable textual format."
::= { swSystem 5 }
swFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..24))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current version of the firwmare."
::= { swSystem 6 }
swOperStatus OBJECT-TYPE
SYNTAX INTEGER {
online (1),
offline (2),
testing (3),
faulty (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of the switch.
The states are as follow:
o online(1) means the switch is accessible by an external
port;
o offline(2) means the switch is not accessible;
o testing(3) means the switch is in a built-in test mode
and is not accessible by an external port;
o faulty(4) means the switch is not operational."
::= { swSystem 7 }
-- 8..9 are reserved; should not be used for new features.
swSsn OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The soft serial number of the switch."
::= { swSystem 10 }
-- FLASH administration
-- the next 5 objects are related to firmware or config file management.
--
-- The underlying method in the transfer of the firmware or config file
-- is based on either FTP or remote shell.
-- If a password is provided, then FTP is used.
-- If NO password is provided, then remote shell is used.
--
-- 2 steps to manage firmware or switch config file in the switch FLASH,
-- (A1) set swFlashDLHost.0, swFlashDLUser.0 and swFlashDLFile.0 to
-- appropriate
-- host IP address in user dot notation (e.g. 192.168.1.7),
-- user name (e.g. "administrator"), and
-- file name of the firmware or config file (e.g. "/home/fcswh/v2.2")
-- respectively;
-- (A2) set swFlashDLPassword.0 to an appropriate value (e.g. "secret")
-- if FTP is the desired method of transfer;
-- (B) set swFlashDLAdmStatus.0 to swFwUpgrade(2), swCfUpload(3),
-- or swCfDownload(4) accordingly.
--
swFlashDLOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
swCurrent (1),
swFwUpgraded (2),
swCfUploaded (3),
swCfDownloaded (4),
swFwCorrupted (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational status of the FLASH.
The operational states are as follow:
o swCurrent(1) indicates that the FLASH contains the
current firmware image or config file;
o swFwUpgraded(2) state indicates that it contains the image
upgraded from the swFlashDLHost.0.;
o swCfUploaded(3) state indicates that the switch configuration
file has been uploaded to the host; and
o swCfDownloaded(4) state indicates that the switch
configuration file has been downloaded from the host.
o swFwCorrupted (5) state indicates that the firmware in the
FLASH of the switch is corrupted."
::= { swSystem 11 }
swFlashDLAdmStatus OBJECT-TYPE
SYNTAX INTEGER {
swCurrent (1),
swFwUpgrade (2),
swCfUpload (3),
swCfDownload (4),
swFwCorrupted (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The state of the FLASH.
o swCurrent(1) indicates that the FLASH contains the
current firmware image or config file;
o swFwUpgrade(2) means that the firmware in the FLASH is to be
upgraded from the host specified;
o swCfUpload(3) means that the switch config file is to be
uploaded to the host specified; or
o swCfDownload(4) means that the switch config file is to be
downloaded from the host specified.
o swFwCorrupted(5) state indicates that the firmware in the
FLASH is corrupted. This value is for informational purpose
only. However, set of swFlashDLAdmStatus to this value is
not allowed.
The host is specified in swFlashDLHost.0. In addition,
user name is specified in swFlashDLUser.0, and
the file name specified in swFlashDLFile.0.
Reference the user manual on the following commands,
o firmwareDownload,
o configUpload, and
o configDownload."
::= { swSystem 12 }
-- 13..17 are reserved
swBeaconOperStatus OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of the switch beacon.
When the beacon is on, the LEDs on the front panel
of the switch run alternately from left to right
and right to left. The color is yellow.
When the beacon is off, each LED will be in their
its regular status indicating color and state."
::= { swSystem 18 }
swBeaconAdmStatus OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The desired status of the switch beacon.
When the beacon is set to on, the LEDs on the front
panel of the switch run alternately from left to right
and right to left. The color is yellow.
When the beacon is set to off, each LED will be in
its regular status indicating color and state."
::= { swSystem 19 }
swDiagResult OBJECT-TYPE
SYNTAX INTEGER {
sw-ok (1),
sw-faulty (2),
sw-embedded-port-fault (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The result of the power-on startup (POST)
diagnostics."
::= { swSystem 20 }
-- operating environment sensors (temperature, fan, power supply...)
swNumSensors OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of sensors inside the switch."
::= { swSystem 21 }
swSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table of sensor entries."
::= { swSystem 22 }
swSensorEntry OBJECT-TYPE
SYNTAX SwSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry of the sensor information."
INDEX { swSensorIndex }
::= { swSensorTable 1 }
SwSensorEntry ::= SEQUENCE {
swSensorIndex SwSensorIndex,
swSensorType INTEGER,
swSensorStatus INTEGER,
swSensorValue Integer32,
swSensorInfo DisplayString
}
swSensorIndex OBJECT-TYPE
SYNTAX SwSensorIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the sensor."
::= { swSensorEntry 1 }
swSensorType OBJECT-TYPE
SYNTAX INTEGER {
temperature (1),
fan (2),
power-supply (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the sensor type."
::= { swSensorEntry 2 }
swSensorStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
faulty (2),
below-min (3),
nominal (4),
above-max (5),
absent (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current status of the sensor."
::= { swSensorEntry 3 }
swSensorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current value (reading) of the sensor.
The value, -2147483648, represents an unknown quantity.
It also means that the sensor does not have the capability to
measure the actual value. In V2.0, the temperature sensor
value will be in Celsius; the fan value will be in RPM
(revolution per minute); and the power supply sensor reading
will be unknown."
::= { swSensorEntry 4 }
swSensorInfo OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Additional displayable information on the sensor.
In V2.x, it contains the sensor type and number
in textual format. For example, 'Temp 3', 'Fan 6'."
::= { swSensorEntry 5 }
-- 23 is reserved
swID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the logical switch (0/1)."
::= { swSystem 24 }
swEtherIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of the Ethernet interface of this logical
switch."
::= { swSystem 25 }
swEtherIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Mask of the Ethernet interface of this logical switch."
::= { swSystem 26}
-- 27..28 are reserved
swIPv6Address OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPV6 address."
::= { swSystem 29 }
swIPv6Status OBJECT-TYPE
SYNTAX INTEGER {
tentative (1),
preferred (2),
ipdeprecated (3),
inactive (4)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The current status of ipv6 address."
::= { swSystem 30 }
--
-- End of System Group
--
--
-- Fibre Channel Port Group
-- This group contains information about the physical state,
-- operational status, performance and error statistics of each
-- Fibre Channel port on the switch. A Fibre Channel port is one which
-- supports the Fibre Channel protocol. E.g. F_Port, E_Port, FL_Port.
--
-- 1 reserved
swFCPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwFCPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains, one entry for each switch port,
configuration and service parameters of the port."
::= { swFCport 2 }
swFCPortEntry OBJECT-TYPE
SYNTAX SwFCPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing the configuration and service
parameters of the switch port."
INDEX { swFCPortIndex }
::= { swFCPortTable 1 }
SwFCPortEntry ::= SEQUENCE {
swFCPortIndex SwPortIndex,
swFCPortType INTEGER,
swFCPortPhyState INTEGER,
swFCPortOpStatus INTEGER,
swFCPortAdmStatus INTEGER,
swFCPortLinkState INTEGER,
swFCPortTxType INTEGER,
-- the rest is mapped to gstat_t
swFCPortTxWords Counter32,
swFCPortRxWords Counter32,
swFCPortTxFrames Counter32,
swFCPortRxFrames Counter32,
swFCPortRxC2Frames Counter32,
swFCPortRxC3Frames Counter32,
swFCPortRxLCs Counter32,
swFCPortRxMcasts Counter32,
swFCPortTooManyRdys Counter32,
swFCPortNoTxCredits Counter32,
swFCPortRxEncInFrs Counter32,
swFCPortRxCrcs Counter32,
swFCPortRxTruncs Counter32,
swFCPortRxTooLongs Counter32,
swFCPortRxBadEofs Counter32,
swFCPortRxEncOutFrs Counter32,
swFCPortRxBadOs Counter32,
swFCPortC3Discards Counter32,
swFCPortMcastTimedOuts Counter32,
swFCPortTxMcasts Counter32,
-- LIP statistics
swFCPortLipIns Counter32,
swFCPortLipOuts Counter32,
swFCPortLipLastAlpa OCTET STRING,
-- new for V2.1
swFCPortWwn OCTET STRING,
-- new for V3.0
swFCPortSpeed INTEGER,
-- new for Port Name Feature.
swFCPortName DisplayString,
-- new for PortSpecifier Feature.
swFCPortSpecifier DisplayString,
-- new for portFlag Feature.
swFCPortFlag FcPortFlag,
-- Brocade port type.
swFCPortBrcdType INTEGER
}
swFCPortIndex OBJECT-TYPE
SYNTAX SwPortIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the switch port index.
Note that the value of a port index is 1 higher than the
port number labeled on the front panel.
E.g. port index 1 correspond to port number 0."
::= { swFCPortEntry 1 }
swFCPortType OBJECT-TYPE
SYNTAX INTEGER {
stitch (1),
flannel (2),
loom (3),
bloom (4),
rdbloom (5),
wormhole (6),
other (7),
unknown (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the type of switch port.
It may be of type stitch(1), flannel(2), loom(3) , bloom(4),rdbloom(5) or wormhole(6)."
::= { swFCPortEntry 2 }
swFCPortPhyState OBJECT-TYPE
SYNTAX INTEGER {
noCard (1),
noTransceiver (2),
laserFault (3),
noLight (4),
noSync (5),
inSync (6),
portFault (7),
diagFault (8),
lockRef (9),
validating (10),
invalidModule (11),
unknown (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the physical state of
the port:
noCard(1) no card present in this switch slot;
noTransceiver(2) no Transceiver module in this port.
noGbic(2) was used previously. Transceiver
is the generic name for GBIC, SFP etc.;
laserFault(3) the module is signaling a laser fault
(defective Transceiver);
noLight(4) the module is not receiving light;
noSync(5) the module is receiving light but is
out of sync;
inSync(6) the module is receiving light and is
in sync;
portFault(7) the port is marked faulty (defective
Transceiver, cable or device);
diagFault(8) the port failed diagnostics (defective
G_Port or FL_Port card or motherboard);
lockRef(9) the port is locking to the reference
signal.
validating(10) Validation is in progress
invalidModule(11) Invalid SFP
unknown(255) unknown.
"
::= { swFCPortEntry 3 }
swFCPortOpStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
online (1),
offline (2),
testing (3),
faulty (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the operational status of
the port. The online(1) state indicates that user frames
can be passed. The unknown(0) state indicates that likely
the port module is physically absent (see swFCPortPhyState)."
::= { swFCPortEntry 4 }
swFCPortAdmStatus OBJECT-TYPE
SYNTAX INTEGER {
online (1),
offline (2),
testing (3),
faulty (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The desired state of the port. A management station
may place the port in a desired state by setting this
object accordingly. The testing(3) state indicates that
no user frames can be passed. As the result of
either explicit management action or per configuration
information accessible by the switch, swFCPortAdmStatus is
then changed to either the online(1) or testing(3)
states, or remains in the offline(2) state."
::= { swFCPortEntry 5 }
swFCPortLinkState OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2),
loopback (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object indicates the link state of the port.
The value may be:
enabled(1) - port is allowed to participate in the FC-PH
protocol with its attached port (or ports if it is
in a FC-AL loop);
disabled(2) - the port is not allowed to participate in
the FC-PH protocol with its attached port(s);
loopback(3) - the port may transmit frames through an
internal path to verify the health of the transmitter
and receiver path.
Note that when the port's link state changes, its
operational status (swFCPortOpStatus) will be affected."
::= { swFCPortEntry 6 }
swFCPortTxType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
lw (2),
sw (3),
ld (4),
cu (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the media transmitter type of
the port. The value may be:
unknown(1) cannot determined to the port driver
lw(2) long wave laser
sw(3) short wave laser
ld(4) long wave LED
cu(5) copper (electrical)."
::= { swFCPortEntry 7 }
-- counters
swFCPortTxWords OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Fibre Channel
words that the port has transmitted."
::= { swFCPortEntry 11 }
swFCPortRxWords OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Fibre Channel
words that the port has received."
::= { swFCPortEntry 12 }
swFCPortTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of (Fibre Channel)
frames that the port has transmitted."
::= { swFCPortEntry 13 }
swFCPortRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of (Fibre Channel)
frames that the port has received."
::= { swFCPortEntry 14 }
swFCPortRxC2Frames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Class 2
frames that the port has received."
::= { swFCPortEntry 15 }
swFCPortRxC3Frames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Class 3
frames that the port has received."
::= { swFCPortEntry 16 }
swFCPortRxLCs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Link Control
frames that the port has received."
::= { swFCPortEntry 17 }
swFCPortRxMcasts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Multicast
frames that the port has received."
::= { swFCPortEntry 18 }
swFCPortTooManyRdys OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of times when RDYs
exceeds the frames received."
::= { swFCPortEntry 19 }
swFCPortNoTxCredits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of times when the
transmit credit has reached zero."
::= { swFCPortEntry 20 }
swFCPortRxEncInFrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of encoding error or
disparity error inside frames received."
::= { swFCPortEntry 21 }
swFCPortRxCrcs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of CRC errors
detected for frames received."
::= { swFCPortEntry 22 }
swFCPortRxTruncs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of truncated
frames that the port has received."
::= { swFCPortEntry 23 }
swFCPortRxTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of received frames that
are too long."
::= { swFCPortEntry 24 }
swFCPortRxBadEofs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of received frames that
have bad EOF delimiter."
::= { swFCPortEntry 25 }
swFCPortRxEncOutFrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of encoding error or
disparity error outside frames received."
::= { swFCPortEntry 26 }
swFCPortRxBadOs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of invalid Ordered
Sets received."
::= { swFCPortEntry 27 }
swFCPortC3Discards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Class 3
frames that the port has discarded."
::= { swFCPortEntry 28 }
swFCPortMcastTimedOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Multicast
frames that has been timed out."
::= { swFCPortEntry 29 }
swFCPortTxMcasts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Multicast
frames that has been transmitted."
::= { swFCPortEntry 30 }
-- LIP statistics
swFCPortLipIns OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Loop Initializations
that has been initiated by loop devices attached."
::= { swFCPortEntry 31 }
swFCPortLipOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object counts the number of Loop Initializations
that has been initiated by the port."
::= { swFCPortEntry 32 }
swFCPortLipLastAlpa OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the Physical Address (AL_PA)
of the loop device that initiated the last
Loop Initialization."
::= { swFCPortEntry 33 }
swFCPortWwn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The World_wide_Name of the Fibre Channel port.
The contents of an instance are in the IEEE extended format
as specified in FC-PH; the 12-bit port identifier represents
the port number within the switch."
::= { swFCPortEntry 34 }
swFCPortSpeed OBJECT-TYPE
SYNTAX INTEGER
{
one-GB (1),
two-GB (2),
auto-Negotiate (3),
four-GB (4),
eight-GB (5),
ten-GB (6),
unknown (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The desired baud rate for the port. It can have the
values of 1GB (1), 2GB (2), Auto-Negotiate (3), 4GB (4), 8GB (5),
or 10GB (6). Some of the above values may not be supported
by all type of switches."
::= { swFCPortEntry 35 }
swFCPortName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A string indicates the name of the addressed port.
The names should be persistent across switch reboots.
Port names do not have to be unique within a switch or
within a fabric."
::= { swFCPortEntry 36 }
swFCPortSpecifier OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This string indicates the physical port number of the addressed port.
The format of the string is: <slot>/port, where 'slot' being
present only for bladed systems.
"
::= { swFCPortEntry 37 }
-- FC port status flag
swFCPortFlag OBJECT-TYPE
SYNTAX FcPortFlag
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit map of port status flags which includes the information of port type.
Currently this will indicate if the port is virtual or physical."
::= { swFCPortEntry 38 }
swFCPortBrcdType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
other (2),
fl-port (3), -- public loop
f-port (4), -- fabric port
e-port (5), -- fabric expansion port
g-port (6), -- generic fabric port
ex-port (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Brocade port type."
::= { swFCPortEntry 39 }
--
-- End of Fibre Channel Port group
--
--
-- swEventTable is defined to gather event info for trap
-- SNMP GET/SET is not supported on this
--
-- possible events available, included her for lib/thresh/fwd.c compilation
SwFwEvent ::= INTEGER {
started(1),
changed(2),
exceeded(3),
below(4),
above(5),
inBetween(6),
lowBufferCrsd(7)
}
swEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table of event entries."
::= { swEvent 5 }
swEventEntry OBJECT-TYPE
SYNTAX SwEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry of the event table."
INDEX { swEventIndex }
::= { swEventTable 1 }
SwEventEntry ::= SEQUENCE {
swEventIndex Integer32,
swEventTimeInfo DisplayString,
swEventLevel INTEGER,
swEventRepeatCount Integer32,
swEventDescr DisplayString,
swEventVfId Integer32
}
swEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the event entry."
::= { swEventEntry 1 }
swEventTimeInfo OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the date and time when this
event occurred, in textual format."
::= { swEventEntry 2 }
swEventLevel OBJECT-TYPE
SYNTAX INTEGER {
critical (1),
error (2),
warning (3),
informational (4),
debug (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the severity level of this
event entry."
::= { swEventEntry 3 }
swEventRepeatCount OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies how many times this particular
event has occurred."
::= { swEventEntry 4 }
swEventDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the textual description of
the event."
::= { swEventEntry 5 }
swEventVfId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the Virtual fabric id."
::= { swEventEntry 6 }
--
-- Enterprise Specific Traps for Switch (sw).
--
swTrapsV2 OBJECT-IDENTITY
STATUS current
DESCRIPTION "The Traps for Brocade's Switch."
::= { sw 0 }
swFCPortScn NOTIFICATION-TYPE
OBJECTS { swFCPortOpStatus, swFCPortIndex, swFCPortName,
swSsn, swFCPortFlag, swVfId }
STATUS current
DESCRIPTION "This trap is sent whenever an FC port operational status or
its type changed. The events that trigger this trap are
port goes to online/offline, port type changed to
E-port/F-port/FL-port. swFCPortName and swSsn are optional
varbind in the trap PDU.swSsn is optional varbind sent when swExtTrap
is also enabled.swVfId is optional if VF is enabled."
--#TYPE "A Fibre Channel Port changed its operational state."
--#SUMMARY "Port Index %d changed state to %d Port Name: %s and SSN is #%s"
--#ARGUMENTS { 1, 0, 2, 3 }
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 1
--#STATE OPERATIONAL
::= { swTrapsV2 3 }
swEventTrap NOTIFICATION-TYPE
OBJECTS { swEventIndex, swEventTimeInfo, swEventLevel,
swEventRepeatCount, swEventDescr, swSsn, swVfId }
STATUS current
DESCRIPTION "This trap is generated when an event whose
level at or below swEventTrapLevel occurs."
--#TYPE "A firmware event has been logged"
--#SUMMARY "Event %d: %s (severity level %d) - %s SSN is #%s"
--#ARGUMENTS { 0, 1, 2, 4, 5 }
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 1
--#STATE OPERATIONAL
::= { swTrapsV2 4 }
swStateChangeTrap NOTIFICATION-TYPE
OBJECTS { swOperStatus, swVfId}
STATUS current
DESCRIPTION "This trap is sent whenever switch state changes to online/offline"
::= { swTrapsV2 12 }
END