OCCAM-SENSOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,
OBJECT-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TimeStamp, TruthValue, DisplayString
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
PhysicalIndex
FROM OCCAM-ENTITY-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
occamGenericHardwareModules
FROM OCCAM-REG-MODULE;
sensorMIB MODULE-IDENTITY
LAST-UPDATED "200104271051Z"
ORGANIZATION "Occam Networks"
CONTACT-INFO "email : support@occamnetworks.com"
DESCRIPTION
"The OCCAM-ENTITY-SENSOR-MIB is used to monitor
the values of Sensors in the BLC1100."
REVISION "200104271051Z"
DESCRIPTION "Reformatted certain text and revised certain
description and syntax sections"
REVISION "201004140000Z"
DESCRIPTION "Updated sensorEventType"
REVISION "200907060000Z"
DESCRIPTION "corrected sensorEventType's syntac to
DisplayString"
REVISION "200702220000Z"
DESCRIPTION "remove DISPLAY-HINT"
::= { occamGenericHardwareModules 2 }
-- TEXTUAL-CONVENTIONS
SensorThresholdRelation ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Sensor threshold relational operator types.
valid values are:
lessThan(1): if the Sensor value is less than
the threshold value
lessOrEqual(2): if the Sensor value is less than or
equal to the threshold value
greaterThan(3): if the Sensor value is greater than
the threshold value
greaterOrEqual(4): if the Sensor value is greater than or
equal to the threshold value
equalTo(5): if the Sensor value is equal to
the threshold value
notEqualTo(6): if the Sensor value is not equal to
the threshold value"
SYNTAX INTEGER{
lessThan(1),
lessOrEqual(2),
greaterThan(3),
greaterOrEqual(4),
equalTo(5),
notEqualTo(6)}
SensorStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the operational status of the
Sensor.
ok(1): The agent can read the Sensor value.
unavailable(2): The agent presently can not report
the Sensor value.
nonoperational(3): The agent believes the Sensor is broken.
The Sensor could have a hard failure
(disconnected wire), or a soft failure
such as out-of-range, jittery, or wildly
fluctuating readings."
SYNTAX INTEGER {
ok(1),
unavailable(2),
nonoperational(3)
}
SensorValue ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"For Sensors that measure voltsAC, voltsDC,
celsius this item is a fixed point number ranging from
-99,999 to +99,999. Use the value
-100000 to indicate underflow. Use the value
+100000 to indicate overflow. Use SensorPrecision to
indicate how many fractional digits the SensorValue has.
For Sensors that measure rpm, this item
can take only nonnegative values, 0..99999."
SYNTAX Integer32 ( -100000 .. 100000 )
SensorDataType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Sensor measurement data types. valid values are:
other(1): a measure other than
those listed below
volts(2): electric potential
celsius(3): temperature
rpm(4): fan revolutions per
minute
milliAmp(5): milliampere
microAmp(6): microampere
milliWatt(7): milliwatt
microWatt(8): microwatt
alarmInput(9): alarm Input
sdram(10): memory SDRAM
usage(11): system resource usage
count(12): ."
SYNTAX INTEGER {
other(1), -- deprecated
volts(2),
celsius(3),
rpm(4),
milliAmp(5),
microAmp(6),
milliWatt(7),
microWatt(8),
alarmInput(9),
sdram(10),
usage(11),
count(12)
}
SensorThresholdSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Sensor threshold severity. Valid values are:
other(1): a severity other than those
listed below.
minor(10): Minor Problem threshold.
major(20): Major Problem threshold.
critical(30): Critical Problem
Threshold."
SYNTAX INTEGER {
other(1),
minor(10),
major(20),
critical(30)
}
SensorDataScale ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "International System of Units (SI) prefixes."
SYNTAX INTEGER {
micro (1), -- 10^-6
milli (2), -- 10^-3
centi (3), -- 10^-2
units (4), -- 10^0
kilo (5), -- 10^3
mega (6) -- 10^6
}
-- identifier statements
sensorMIBObjects OBJECT IDENTIFIER
::= { sensorMIB 1 }
--traps
sensorMIBTraps OBJECT IDENTIFIER
::= {sensorMIB 2 }
sensorMIBTrapsSubID OBJECT IDENTIFIER
::= { sensorMIBTraps 0}
--conformance statements
sensorMIBConformance OBJECT IDENTIFIER
::= {sensorMIB 3 }
sensorMIBGroups OBJECT IDENTIFIER
::= { sensorMIBConformance 1 }
sensorMIBCompliances OBJECT IDENTIFIER
::= { sensorMIBConformance 2 }
--
-- MIB variables
--
sensorValues OBJECT IDENTIFIER
::= { sensorMIBObjects 1 }
sensorThresholds OBJECT IDENTIFIER
::= { sensorMIBObjects 2 }
--
-- notifications
--
sensorThresholdNotification NOTIFICATION-TYPE
OBJECTS { sensorName,
sensorType,
sensorThresholdValue,
sensorThresholdSeverity,
sensorEventType
}
STATUS current
DESCRIPTION
"The Sensor value crossed the threshold
listed in sensorThresholdTable.
This notification is generated once each time
the Sensor value crosses the threshold.
The agent implementation guarantees prompt, timely
evaluation of threshold and generation of this
notification."
::= { sensorMIBTrapsSubID 1 }
occamExtAlarmRaised NOTIFICATION-TYPE
OBJECTS { occamExtAlarmDescription }
STATUS current
DESCRIPTION
"An external alarm has been detected, the alarm
is described in the associated variable binding."
::= {sensorMIBTrapsSubID 2}
occamExtAlarmCleared NOTIFICATION-TYPE
OBJECTS {occamExtAlarmDescription }
STATUS current
DESCRIPTION
"The condition causing the external alarm has
been cleared, the alarm is described in the
associated variable binding."
::={ sensorMIBTrapsSubID 3}
sensorMIBObjectGroups OBJECT IDENTIFIER
::= { sensorMIBGroups 1 }
sensorMIBEventGroups OBJECT IDENTIFIER
::= { sensorMIBGroups 2 }
--
-- compliance statements
--
sensorMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"An Entity-MIB implementation that lists
Sensors in its entPhysicalTable must implement
this group."
MODULE
MANDATORY-GROUPS { sensorGroup
,sensorThresholdGroup }
::= { sensorMIBCompliances 1 }
--
-- sensorTable
--
sensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the type, scale, and present value
of a Sensor in the BLC1100."
::= { sensorValues 1 }
sensorEntry OBJECT-TYPE
SYNTAX SensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An sensorTable entry describes the
present reading of a Sensor, the measurement units
and scale, and Sensor operational status."
INDEX { sensorIndex }
::= { sensorTable 1 }
SensorEntry ::= SEQUENCE {
sensorIndex PhysicalIndex,
sensorName SnmpAdminString,
sensorType SensorDataType,
sensorValue SensorValue,
sensorScale SensorDataScale,
sensorTimeStamp TimeStamp,
sensorEventType DisplayString
}
sensorIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This serves as an index for identifying
the sensor."
::= { sensorEntry 1 }
sensorName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the textual description of the name of the
sensor.For e.g., in the BLC1100 there are two
temperature Sensors,and their locations
ExternalTempSensor and InternalTempSensor."
::= { sensorEntry 2 }
sensorType OBJECT-TYPE
SYNTAX SensorDataType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the type of data reported by
the sensorValue. This variable is set by the agent at
start-up and the value does not change during
operation."
::= { sensorEntry 3 }
sensorValue OBJECT-TYPE
SYNTAX SensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable reports the most recent measurement seen
by the Sensor. To correctly display or interpret this
variable's value, you must also know sensorType,
sensorScale, and sensorPrecision. However, you can
compare sensorValue with the threshold values given in
sensorThresholdTable without any semantic knowledge."
::= { sensorEntry 4 }
sensorScale OBJECT-TYPE
SYNTAX SensorDataScale
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable indicates the exponent to apply
to sensor values reported by entSensorValue.
This variable is set by the agent at start-up
and the value does not change during operation."
::= { sensorEntry 5 }
sensorTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the age of the value reported
by sensorValue"
::= { sensorEntry 6 }
sensorEventType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the event type reported by
the sensor. The possible values are:
Cleared,
LowLimitExceeded,
HighLimitExceeded,
AlarmInOn,
AlarmInOff,
FanFastSpeed,
FanSlowSpeed,
wrongSfp."
::= { sensorEntry 7 }
occamExtAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This is the value of the alarm-description as
entered by the user. The string is associated with
the external alarm detection mechanism and as a
variable binding for the occamExtAlarmRaised and
occamExtAlarmCleared SNMP Traps "
::= { sensorValues 2 }
--
-- sensorThresholdTable
--
sensorThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntSensorThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the threshold severity, relation, and
comparison value for a Sensor listed in the sensor
Table."
::= { sensorThresholds 1 }
sensorThresholdEntry OBJECT-TYPE
SYNTAX EntSensorThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An sensorThresholdTable entry describes the
thresholds for a Sensor: the threshold severity,
the threshold value, the relation, and the
evaluation of the threshold.
Only pre-configured thresholds are listed in this table.
Entries are created by the agent at system startup."
INDEX { sensorThresholdIndex, sensorIndex}
::= { sensorThresholdTable 1 }
EntSensorThresholdEntry ::= SEQUENCE {
sensorThresholdIndex Integer32,
sensorThresholdSeverity SensorThresholdSeverity,
sensorThresholdRelation SensorThresholdRelation,
sensorThresholdValue SensorValue,
sensorThresholdNotificationEnable TruthValue
}
sensorThresholdIndex OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 99999999 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the sensorThreshold table. This index permits
the same Sensor to have several different thresholds."
::= { sensorThresholdEntry 1 }
sensorThresholdSeverity OBJECT-TYPE
SYNTAX SensorThresholdSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the severity of this
threshold."
::= { sensorThresholdEntry 2 }
sensorThresholdRelation OBJECT-TYPE
SYNTAX SensorThresholdRelation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the relation between Sensor
value (sensorValue) and threshold value
senshresholdValue), required to trigger the alarm. when
evaluating the relation, sensorValue is on the left of
sensorThresholdRelation, sensorThresholdValue is on the
right. in pseudo-code, the evaluation-alarm mechanism
is:
...
if (sensorStatus == ok)
then
if (evaluate(sensorValue, sensorThresholdRelation,
sensorThresholdValue))
then
if (sensorThresholdNotificationEnable == true))
then
raise_alarm(sensorThresholdAlarmOID);
endif
endif
endif
..."
::= { sensorThresholdEntry 3 }
sensorThresholdValue OBJECT-TYPE
SYNTAX SensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the value of the threshold.
To correctly display or interpret this variable's value,
you must also know sensorType, sensorScale, and
sensorPrecision.
However, you can directly compare sensorValue
with the threshold values given in sensorThresholdTable
without any semantic knowledge."
::= { sensorThresholdEntry 4 }
sensorThresholdNotificationEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls generation of
sensorThresholdNotification for this threshold.
When this variable is true(1), generation of
sensorThresholdNotification is enabled. When this
variable is false(2), generation of
sensorThresholdNotification is disabled.
This variable only controls generation of
sensorThresholdNotification."
::= { sensorThresholdEntry 5 }
--
-- units of conformance
--
sensorGroup OBJECT-GROUP
OBJECTS { sensorType , sensorValue ,
sensorTimeStamp , sensorName }
STATUS current
DESCRIPTION
"The collection of objects which are used
to describe and monitor values of Entity-MIB
entPhysicalTable entries of Sensors."
::= { sensorMIBObjectGroups 1 }
sensorThresholdGroup OBJECT-GROUP
OBJECTS { sensorThresholdSeverity
,sensorThresholdRelation
,sensorThresholdValue
,sensorThresholdNotificationEnable }
STATUS current
DESCRIPTION
"The collection of objects which are used
to describe and monitor thresholds for Sensors."
::= { sensorMIBObjectGroups 2 }