mibs/MIBS/cambium/500/CAMBIUM-PTP500-MIB

2589 lines
90 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CAMBIUM-PTP500-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress,
enterprises
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC;
cambium MODULE-IDENTITY
LAST-UPDATED "201403141604Z"
ORGANIZATION "Cambium Networks Ltd."
CONTACT-INFO
"Post: Simon Whitaker
Cambium Networks Ltd.
Unit B2,
Linhay Business Park,
Eastern Road,
Ashburton,
Devon.
TQ13 7UP
United Kingdom
Phone: +44 (0) 1364 655 500
Email: simon.whitaker@cambiumnetworks.com"
DESCRIPTION
"MIB for 105Mbps non-line-of-sight (NLOS) wireless ethernet bridge."
REVISION "201403141604Z"
DESCRIPTION "PTP500-05-04:
Added aAAControl group containing user table."
REVISION "201302080838Z"
DESCRIPTION "PTP500-05-03:
Removed encryptionEnabledMismatchTrap.
Renamed dfsChannelChangeTrap to channelChangeTrap."
REVISION "201207091750Z"
DESCRIPTION "PTP500-05-02:
Corrected REVISION DESCRIPTION clause for 05-01."
REVISION "201203281037Z"
DESCRIPTION "PTP500-05-01:
Updated ORGANIZATION and CONTACT-INFO.
Replaced syslogLocalLog with syslogState.
Added licensedCapacity and capacityLicenseMismatchTrap as part of SKU reduction.
Added support for HTTPS.
Added enabledDiagnosticAlarms attribute.
Added support for syslog client.
Removed lineOfSightModeInactive trap as part of SKU reduction (LOS no longer supported)."
REVISION "201107131657Z"
DESCRIPTION "PTP500-04-01:
Added latitude, longitude, altitude, searchState, accessMethod and groupID."
REVISION "201009221449Z"
DESCRIPTION "PTP500-04-00:
Changed root OID.
Added SNMPv3 support, TDD sync, DFS Table, BIT STRING types now OCTET STRING.
Added linkName, siteName.
Renamed ethernet attributes & traps."
REVISION "200905290925Z"
DESCRIPTION "PTP500-03-02: Added Telecoms circuit emulation."
REVISION "200811041022Z"
DESCRIPTION "PTP500-03-00: Added Link Symmetry."
REVISION "200806261644Z"
DESCRIPTION "PTP500-02-00: Added IEEE 802.1q & 802.1ad VLAN support."
REVISION "200804111808Z"
DESCRIPTION "PTP500-01-00"
::= { enterprises 17713 }
-- Groups in cambium
ptp OBJECT IDENTIFIER ::= { cambium 1 }
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
ptp500 OBJECT IDENTIFIER ::= { cambium 5 }
-- Groups in ptp500
dfs OBJECT IDENTIFIER ::= { ptp500 3 }
configuration OBJECT IDENTIFIER ::= { ptp500 5 }
ethernet OBJECT IDENTIFIER ::= { ptp500 6 }
telecom OBJECT IDENTIFIER ::= { ptp500 7 }
licence OBJECT IDENTIFIER ::= { ptp500 8 }
management OBJECT IDENTIFIER ::= { ptp500 9 }
phyControl OBJECT IDENTIFIER ::= { ptp500 10 }
phyStatus OBJECT IDENTIFIER ::= { ptp500 12 }
alarms OBJECT IDENTIFIER ::= { ptp500 13 }
smtp OBJECT IDENTIFIER ::= { ptp500 15 }
snmpControl OBJECT IDENTIFIER ::= { ptp500 16 }
sntp OBJECT IDENTIFIER ::= { ptp500 17 }
reset OBJECT IDENTIFIER ::= { ptp500 18 }
versions OBJECT IDENTIFIER ::= { ptp500 19 }
pubStats OBJECT IDENTIFIER ::= { ptp500 20 }
encryption OBJECT IDENTIFIER ::= { ptp500 22 }
tDDControl OBJECT IDENTIFIER ::= { ptp500 23 }
aAAControl OBJECT IDENTIFIER ::= { ptp500 25 }
syslogControl OBJECT IDENTIFIER ::= { ptp500 24 }
supplementary OBJECT IDENTIFIER ::= { ptp500 96 }
ptpGroups OBJECT IDENTIFIER ::= { ptp500 98 }
ptpTraps OBJECT IDENTIFIER ::= { ptp500 99 }
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
-- Compliance information
--
ptpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Cambium PTP MIB"
MODULE -- this module
MANDATORY-GROUPS { dfsGroup
, configurationGroup
, ethernetGroup
, telecomGroup
, licenceGroup
, managementGroup
, phyControlGroup
, phyStatusGroup
, alarmsGroup
, smtpGroup
, snmpControlGroup
, sntpGroup
, resetGroup
, versionsGroup
, pubStatsGroup
, encryptionGroup
, tDDControlGroup
, aAAControlGroup
, syslogControlGroup
, supplementaryGroup
, notificationsGroup
}
::= { ptp500 97 }
dfsGroup OBJECT-GROUP
OBJECTS { dfsTableNumber
, dfsMeans
, dfsNineNinePointNinePercentiles
, dfsPeaks
}
STATUS current
DESCRIPTION "The dfs object group."
::= { ptpGroups 3 }
configurationGroup OBJECT-GROUP
OBJECTS { iPAddress
, subnetMask
, gatewayIPAddress
, targetMACAddress
, masterSlaveMode
, maximumTransmitPower
, antennaGain
, cableLoss
, eIRP
, channelBandwidth
, remoteIPAddress
, linkName
, siteName
, accessMethod
, groupID
}
STATUS current
DESCRIPTION "The configuration object group."
::= { ptpGroups 5 }
ethernetGroup OBJECT-GROUP
OBJECTS { dataPortAutoNegotiation
, dataPortAutoNegAdvertisement
, dataPortAutoMdix
, dataPortStatus
, dataPortSpeedAndDuplex
, dataPortWirelessDownAlert
, useVLANForManagementInterfaces
, vLANManagementPriority
, vLANManagementVID
, vLANPriorityTableNumber
, vLANPriorityQueueMapping
}
STATUS current
DESCRIPTION "The ethernet object group."
::= { ptpGroups 6 }
telecomGroup OBJECT-GROUP
OBJECTS { telecomsInterface
, telecomsChannelStatus
, telecomsLineCode
, telecomsCableLength
, telecomsLoopback
}
STATUS current
DESCRIPTION "The telecom object group."
::= { ptpGroups 7 }
licenceGroup OBJECT-GROUP
OBJECTS { regionCode
, productVariant
, productName
, ethernetFiberSupport
, frequencyVariant
, bandwidthVariant
, constantPowerSpectralDensity
, sNMPv3Enable
, licensedCapacity
}
STATUS current
DESCRIPTION "The licence object group."
::= { ptpGroups 8 }
managementGroup OBJECT-GROUP
OBJECTS { installStatus
, installArmState
, tFTPServerIPAddress
, tFTPServerPortNumber
, tFTPSoftwareUpgradeFileName
, tFTPStartSoftwareUpgrade
, tFTPSoftwareUpgradeStatus
, tFTPSoftwareUpgradeStatusText
, tFTPSoftwareUpgradeStatusAdditionalText
, hTTPAccessEnabled
, telnetAccessEnabled
, hTTPPortNumber
, hTTPSPortNumber
, telnetPortNumber
, hTTPSAccessEnabled
}
STATUS current
DESCRIPTION "The management object group."
::= { ptpGroups 9 }
phyControlGroup OBJECT-GROUP
OBJECTS { linkSymmetry
, linkModeOptimisation
, userConfiguredMaxModulationMode
, remoteMaximumTransmitPower
}
STATUS current
DESCRIPTION "The phyControl object group."
::= { ptpGroups 10 }
phyStatusGroup OBJECT-GROUP
OBJECTS { receivePower
, vectorError
, transmitPower
, range
, linkLoss
, receiveChannel
, transmitChannel
, receiveModulationMode
, transmitModulationMode
, receiveFreqMHz
, transmitFreqMHz
, signalStrengthRatio
, receiveFreqKHz
, transmitFreqKHz
, searchState
}
STATUS current
DESCRIPTION "The phyStatus object group."
::= { ptpGroups 12 }
alarmsGroup OBJECT-GROUP
OBJECTS { unitOutOfCalibration
, incompatibleRegionCodes
, noWirelessChannelAvailable
, wirelessLinkDisabledWarning
, dataPortDisabledWarning
, dataPortConfigurationMismatch
, incompatibleMasterAndSlave
, tDDSynchronizationStatus
, tDDSynchronizationAlarm
, linkModeOptimizationMismatch
, capacityLicenseMismatch
}
STATUS current
DESCRIPTION "The alarms object group."
::= { ptpGroups 13 }
smtpGroup OBJECT-GROUP
OBJECTS { sMTPEmailAlert
, sMTPServerIPAddress
, sMTPServerPortNumber
, sMTPSourceEmailAddress
, sMTPDestinationEmailAddress
, sMTPEnabledMessages
}
STATUS current
DESCRIPTION "The smtp object group."
::= { ptpGroups 15 }
snmpControlGroup OBJECT-GROUP
OBJECTS { sNMPPortNumber
, sNMPCommunityString
, sNMPTrapTableNumber
, sNMPTrapVersion
, sNMPEnabledTraps
, enabledDiagnosticAlarms
, sNMPSendAllTrapsAtStartup
, sNMPTrapIPAddress
, sNMPTrapPortNumber
}
STATUS current
DESCRIPTION "The snmpControl object group."
::= { ptpGroups 16 }
sntpGroup OBJECT-GROUP
OBJECTS { sNTPState
, sNTPServerIPAddress
, sNTPServerPortNumber
, sNTPPollInterval
, sNTPSync
, sNTPLastSync
, systemClock
, timeZone
, daylightSaving
}
STATUS current
DESCRIPTION "The sntp object group."
::= { ptpGroups 17 }
resetGroup OBJECT-GROUP
OBJECTS { systemReset
}
STATUS current
DESCRIPTION "The reset object group."
::= { ptpGroups 18 }
versionsGroup OBJECT-GROUP
OBJECTS { softwareVersion
, hardwareVersion
, secondarySoftwareVersion
, bootVersion
}
STATUS current
DESCRIPTION "The versions object group."
::= { ptpGroups 19 }
pubStatsGroup OBJECT-GROUP
OBJECTS { receiveDataRate
, transmitDataRate
, aggregateDataRate
, wirelessLinkAvailability
, wirelessLinkStatus
, byteErrorRatio
, receiveModulationModeDetail
}
STATUS current
DESCRIPTION "The pubStats object group."
::= { ptpGroups 20 }
encryptionGroup OBJECT-GROUP
OBJECTS { encryptionAlgorithm
}
STATUS current
DESCRIPTION "The encryption object group."
::= { ptpGroups 22 }
tDDControlGroup OBJECT-GROUP
OBJECTS { tDDSynchronizationMode
}
STATUS current
DESCRIPTION "The tDDControl object group."
::= { ptpGroups 23 }
aAAControlGroup OBJECT-GROUP
OBJECTS { userTableNumber
, userName
, userRole
, userEnabled
, userPassword
}
STATUS current
DESCRIPTION "The aAAControl object group."
::= { ptpGroups 25 }
syslogControlGroup OBJECT-GROUP
OBJECTS { syslogClient
, syslogState
}
STATUS current
DESCRIPTION "The syslogControl object group."
::= { ptpGroups 24 }
supplementaryGroup OBJECT-GROUP
OBJECTS { longitude
, latitude
, altitude
}
STATUS current
DESCRIPTION "The supplementary object group."
::= { ptpGroups 96 }
notificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { channelChangeTrap
, dfsImpulsiveInterferenceTrap
, dataPortStatusTrap
, telecomsChannelStatusTrap
, telecomsLoopbackTrap
, regionCodeTrap
, installStatusTrap
, installArmStateTrap
, unitOutOfCalibrationTrap
, incompatibleRegionCodesTrap
, noWirelessChannelAvailableTrap
, wirelessLinkDisabledWarningTrap
, dataPortDisabledWarningTrap
, dataPortConfigurationMismatchTrap
, incompatibleMasterAndSlaveTrap
, sNTPSyncTrap
, tDDSynchronizationAlarmTrap
, linkModeOptimizationMismatchTrap
, capacityLicenseMismatchTrap
, syslogStateTrap
, syslogLocalNearlyFullTrap
, syslogLocalWrappedTrap
, syslogClientTrap
}
STATUS current
DESCRIPTION "The notifications group."
::= { ptpGroups 99 }
DfsTableEntry ::=
SEQUENCE { dfsTableIndex INTEGER
, dfsMeans Integer32
, dfsNineNinePointNinePercentiles Integer32
, dfsPeaks Integer32
}
dfsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A table storing a snapshot of various DFS measurements for each channel"
::= { dfs 2 }
dfsTableEntry OBJECT-TYPE
SYNTAX DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table DfsTable"
INDEX { dfsTableIndex }
::= { dfsTable 1 }
VLANPriorityTableEntry ::=
SEQUENCE { vLANPriorityQueueMapping INTEGER
, vLANPriorityTableIndex INTEGER
}
vLANPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF VLANPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by VLAN priority."
::= { ethernet 15 }
vLANPriorityTableEntry OBJECT-TYPE
SYNTAX VLANPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table VLANPriorityTable"
INDEX { vLANPriorityTableIndex }
::= { vLANPriorityTable 1 }
SNMPTrapTableEntry ::=
SEQUENCE { sNMPTrapTableIndex INTEGER
, sNMPTrapIPAddress IpAddress
, sNMPTrapPortNumber INTEGER
}
sNMPTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" SNMP trap configuration table."
::= { snmpControl 4 }
sNMPTrapTableEntry OBJECT-TYPE
SYNTAX SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPTrapTable"
INDEX { sNMPTrapTableIndex }
::= { sNMPTrapTable 1 }
UserTableEntry ::=
SEQUENCE { userTableIndex INTEGER
, userName OCTET STRING
, userRole INTEGER
, userEnabled INTEGER
, userPassword OCTET STRING
}
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The User Table Control group contains objects specifically for user account management."
::= { aAAControl 2 }
userTableEntry OBJECT-TYPE
SYNTAX UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table UserTable"
INDEX { userTableIndex }
::= { userTable 1 }
-- Dfs group attribute definitions
--
dfsTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the dfsTable"
::= { dfs 1 }
-- DfsTable group attribute definitions
--
dfsTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the dfsTable."
::= { dfsTableEntry 1 }
dfsMeans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS means"
::= { dfsTableEntry 2 }
dfsNineNinePointNinePercentiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS 99.9 percentiles"
::= { dfsTableEntry 3 }
dfsPeaks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS peaks"
::= { dfsTableEntry 4 }
-- Configuration group attribute definitions
--
iPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IP) address. This address is used by
the family of Internet protocols to uniquely identify the
unit on a network. NB: A system reboot is required to
activate changes to this attribute."
::= { configuration 1 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A subnet allows the flow of network traffic between
hosts to be segregated based on a network configuration.
By organizing hosts into logical groups, subnetting can
improve network security and performance. NB: A system
reboot is required to activate changes to this attribute"
::= { configuration 2 }
gatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of a computer on the current network that
is currently acting as a network gateway. A gateway acts
as an entrance / exit to packets from / to other
networks. NB: A system reboot is required to activate
changes to this attribute"
::= { configuration 3 }
targetMACAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the PTP wireless unit forming the other
end of the PTP link"
::= { configuration 4 }
masterSlaveMode OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PTP wireless link operates using a master and slave
relationship"
::= { configuration 5 }
maximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-100..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the wireless unit is permitted to
use when establishing and maintaining the wireless link"
::= { configuration 6 }
antennaGain OBJECT-TYPE
SYNTAX INTEGER (0..610)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Antenna Gain. Expressed in 10ths of dBi. NB: This
attribute is ignored for variants with an integral
antenna."
::= { configuration 7 }
cableLoss OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loss in the cable between the ODU and the antenna.
Expressed in 10ths of dB. NB: This attribute is ignored
for variants with an integral antenna."
::= { configuration 8 }
eIRP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective Isotropic Radiated Power (EIRP) describes the
strength of the radio signal leaving the wireless unit.
Expressed in 10ths of dBm"
::= { configuration 9 }
channelBandwidth OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This control sets the bandwidth of the transmit and
receive radio channels"
::= { configuration 11 }
remoteIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address of the peer wireless unit"
::= { configuration 12 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the PTP link allocated by the System
Administrator. Used to establish a connection with the
correct PTP wireless unit at the other end of the link.
NOTE: The link name MUST be the same at both ends of the
PTP link."
::= { configuration 14 }
siteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field contains a user-provided description of the
site name together with any additional notes"
::= { configuration 15 }
accessMethod OBJECT-TYPE
SYNTAX INTEGER {
linkAccess(0),
linkNameAccess(1),
groupAccess(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether the link can be established
between pre-paired Master-Slave using MAC addresses (Link
Access) or by using link name (Link Name Access)"
::= { configuration 16 }
groupID OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When Access Method is set to Group Access, the Group ID
identifies all the units belonging to the same group.
Group Access is only supported on some platforms"
::= { configuration 17 }
-- Ethernet group attribute definitions
--
dataPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 1 }
dataPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
negUnknown1(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation. NB: The new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 2 }
dataPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 3 }
dataPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ethernet 4 }
dataPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Ethernet link"
::= { ethernet 5 }
dataPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, this causes the Ethernet link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 6 }
useVLANForManagementInterfaces OBJECT-TYPE
SYNTAX INTEGER {
noVLANTagging(0),
iEEE8021QTaggedCTagType8100(1),
iEEE8021adTaggedSTagorBTagType88a8(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the management interfaces
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 7 }
vLANManagementPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN Priority (0-7) will be included in packets
generated by the management interfaces. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 8 }
vLANManagementVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN VID (0-4094) will be included in packets
generated by the management interfaces. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 11 }
vLANPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the vLANPriorityTable."
::= { ethernet 14 }
-- VLANPriorityTable group attribute definitions
--
vLANPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mapping of VLAN priority flag to packet queue. The
higher the queue number the greater its priority."
::= { vLANPriorityTableEntry 1 }
vLANPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8),
untagged(9)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN priority flag, used to index values in the
vLANPriorityTable."
::= { vLANPriorityTableEntry 2 }
-- Telecom group attribute definitions
--
telecomsInterface OBJECT-TYPE
SYNTAX INTEGER {
none(0),
e1(1),
t1(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line interface type. If this is set to 'None' then
the telecoms interfaces are disabled, and the telecom
group attributes will be ignored."
::= { telecom 1 }
telecomsChannelStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
up(4),
remoteTiming(5),
noSignalLocalandRemoteTiming(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of telecoms channel. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { telecom 2 }
telecomsLineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the telecoms interface. This
must match the setting of the device connected to this
interface"
::= { telecom 4 }
telecomsCableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the cable connected to the telecoms
interface, measured in feet"
::= { telecom 6 }
telecomsLoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of telecoms channel. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. When
applying a wireless loopback, please ensure that the
other end of the link has a loopback setting of 'None'.
NB: a change of state may generate an SNMP trap and/or
SMTP email alert"
::= { telecom 8 }
-- Licence group attribute definitions
--
regionCode OBJECT-TYPE
SYNTAX INTEGER {
regionCodeInvalid(0),
regionCode1(1),
regionCode2(2),
regionCode3(3),
regionCode4(4),
regionCode5(5),
regionCode6(6),
regionCode7(7),
regionCode8(8),
regionCode9(9),
regionCode10(10),
regionCode11(11),
regionCode12(12),
regionCode13(13),
regionCode14(14),
regionCode15(15),
regionCode16(16),
regionCode17(17),
regionCode18(18),
regionCode19(19),
regionCode20(20),
regionCode21(21),
regionCode22(22),
regionCode23(23),
regionCode24(24),
regionCode25(25),
regionCode26(26),
regionCode27(27),
regionCode28(28),
regionCode29(29),
regionCode30(30),
regionCode31(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted licence key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { licence 1 }
productVariant OBJECT-TYPE
SYNTAX INTEGER {
pTPxx400Full(0),
pTPxx400Deprecated1(1),
pTPxx400Deprecated2(2),
pTPxx400Lite(3),
spare1(4),
pTPxx300(5),
spare2(6),
spare3(7),
pTPxx500FullDeprecated(8),
pTPxx500LiteDeprecated(9),
pTPxx500(10),
pTPxx600Lite(11),
pTPxx600Full(12),
spare5(13),
spare6(14),
pTP800(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product variant"
::= { licence 2 }
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the product variant"
::= { licence 3 }
ethernetFiberSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet fiber support availability on this wireless
unit"
::= { licence 4 }
frequencyVariant OBJECT-TYPE
SYNTAX INTEGER {
freq5800MHz(0),
freq5400MHz(1),
freq4900MHz(2),
freq2500MHz(3),
freq5800MHz2(4),
freq5400MHz2(5),
freq4500MHz(6),
freq5900MHz(7),
freq5200MHz(8),
freq5100MHz(9),
freq4800MHz(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency variant of the wireless unit"
::= { licence 5 }
bandwidthVariant OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bandwidth variant of the wireless unit"
::= { licence 6 }
constantPowerSpectralDensity OBJECT-TYPE
SYNTAX INTEGER {
constant(0),
fullPower(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Constant power spectral density mode control"
::= { licence 7 }
sNMPv3Enable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMPv3 availability control"
::= { licence 9 }
licensedCapacity OBJECT-TYPE
SYNTAX INTEGER {
capacity25Mbps(0),
capacity52Mbps(1),
capacity105Mbps(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum allowable data rate for ethernet frames
permitted by the licence key. The actual data rate
depends upon the prevailing wireless conditions"
::= { licence 11 }
-- Management group attribute definitions
--
installStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
wrongPeer(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { management 3 }
installArmState OBJECT-TYPE
SYNTAX INTEGER {
disarmed(0),
armed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a value
other than 'disarmed' on startup, or a change of state
during operation may generate an SNMP trap and/or SMTP
email alert"
::= { management 4 }
tFTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 5 }
tFTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 6 }
tFTPSoftwareUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename of the Software Upgrade to be loaded from the
TFTP Server"
::= { management 7 }
tFTPStartSoftwareUpgrade OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write '1' to this attribute to start the TFTP software
upgrade process. The attribute will be reset to 0 when
the upgrade process has finished"
::= { management 8 }
tFTPSoftwareUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
uploadinprogress(1),
uploadsuccessfulprogrammingFLASH(2),
upgradesuccessfulreboottorunthenewsoftwareimage(3),
upgradefailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the TFTP Software upgrade process"
::= { management 9 }
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descriptive text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 10 }
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any additional text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 11 }
hTTPAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTP access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTP port. Remote
management via HTTPS is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 12 }
telnetAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not Telnet access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the TELNET port. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = Disabled)"
::= { management 13 }
hTTPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTP access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 80)"
::= { management 14 }
hTTPSPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTPS access. A value
of zero will use the default port number. Availability of
HTTPS is controlled via the Licence Key. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 443)"
::= { management 15 }
telnetPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for TELNET access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 23)"
::= { management 16 }
hTTPSAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTPS access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTPS port. Remote
management via HTTP is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 17 }
-- PhyControl group attribute definitions
--
linkSymmetry OBJECT-TYPE
SYNTAX INTEGER {
symmetryAdaptive(0),
symmetry3to1(1),
symmetry1to1(2),
symmetry1to3(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In fixed asymmetric mode (3 to 1) the transmit time is
three times as long as the receive time. In fixed
symmetric mode (1 to 1) the unit spends an equal amount
of time transmitting and receiving. In fixed asymmetric
mode (1 to 3) the receive time is three times as long as
the transmit time. In adaptive mode the transmit and
receive periods adjust with applied load. NB: only
applicable for master nodes."
::= { phyControl 1 }
linkModeOptimisation OBJECT-TYPE
SYNTAX INTEGER {
iPTraffic(0),
tDMTraffic(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optimises the wireless link behavior for the type of
traffic to be carried. In 'IP Traffic' mode, the wireless
link will minimise transmission errors by automatically
adapting the modulation mode. In 'TDM Traffic' mode, the
wireless link will minimise transmission latency and
preserve throughput by maintaining a higher modulation
mode in the presence of a limited number of errors. The
'TDM Traffic' mode is recommended for E1/T1 applications
and connectionless protocols."
::= { phyControl 2 }
userConfiguredMaxModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modBpsk50percent(0),
modQpsk50percent(1),
modQpsk75percent(2),
mod16qam50percent(3),
mod16qam75percent(4),
mod64qam67percent(5),
mod64qam83percent(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum receive modulation mode controls the MAX
mode used for adaptive modulation. NOTE: This attribute
is automatically disabled when the installation agent is
armed. To disarm the installation agent use the
installation wizard"
::= { phyControl 3 }
remoteMaximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-100..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the remote wireless unit is
permitted to use when establishing and maintaining the
wireless link"
::= { phyControl 4 }
-- PhyStatus group attribute definitions
--
receivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power expressed in tenths of a dBm"
::= { phyStatus 1 }
vectorError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vector error measurement compares the received
signal's IQ modulation characteristics to an ideal signal
to determine the composite error vector magnitude. The
value represented by this attribute is the average vector
error over the previous second expressed in tenths of a
dB"
::= { phyStatus 2 }
transmitPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit power expressed in tenths of a dBm"
::= { phyStatus 3 }
range OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance between the two peer wireless units expressed
in tenths of a kilometer"
::= { phyStatus 4 }
linkLoss OBJECT-TYPE
SYNTAX INTEGER (-500..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link loss expressed in tenths of a dB"
::= { phyStatus 5 }
receiveChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive channel"
::= { phyStatus 6 }
transmitChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit channel"
::= { phyStatus 7 }
receiveModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk50percent(1),
modQpsk50percentSingle(2),
modQpsk75percentSingle(3),
mod16qam50percentSingle(4),
mod16qam75percentSingle(5),
mod64qam67percentSingle(6),
mod64qam83percentSingle(7),
modReserved1(8),
modQpsk50percentDual(9),
modQpsk75percentDual(10),
mod16qam50percentDual(11),
mod16qam75percentDual(12),
mod64qam67percentDual(13),
mod64qam83percentDual(14),
modReserved2(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive modulation mode"
::= { phyStatus 8 }
transmitModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk50percent(1),
modQpsk50percentSingle(2),
modQpsk75percentSingle(3),
mod16qam50percentSingle(4),
mod16qam75percentSingle(5),
mod64qam67percentSingle(6),
mod64qam83percentSingle(7),
modReserved1(8),
modQpsk50percentDual(9),
modQpsk75percentDual(10),
mod16qam50percentDual(11),
mod16qam75percentDual(12),
mod64qam67percentDual(13),
mod64qam83percentDual(14),
modReserved2(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit modulation mode"
::= { phyStatus 9 }
receiveFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed in integer MHz"
::= { phyStatus 11 }
transmitFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed in integer MHz"
::= { phyStatus 12 }
signalStrengthRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal strength ratio (Vertical / Horizontal) : the
number of dB larger the Vertical antenna input is than
the Horizontal antenna input expressed in tenths of a dB"
::= { phyStatus 13 }
receiveFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed as KHz"
::= { phyStatus 14 }
transmitFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed as KHz"
::= { phyStatus 15 }
searchState OBJECT-TYPE
SYNTAX INTEGER {
registering(0),
searching(1),
acquiring(2),
registeringAcquiring2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Search status of the wireless modem. 'Registering' means
that the modem has locked to an OFDM signal, and the
wireless link is up. 'Searching' means that no wireless
signal has been detected. 'Acquiring' means that a
wireless signal has been detected, but the modem has not
locked to an OFDM signal."
::= { phyStatus 16 }
-- Alarms group attribute definitions
--
unitOutOfCalibration OBJECT-TYPE
SYNTAX INTEGER {
calibrated(0),
partialCalibration(1),
invalidCalibration(2),
bandwidthvariantunsupportedPAsShutdown(3),
outOfCalibrationPAsShutdown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { alarms 1 }
incompatibleRegionCodes OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleLicenceKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible licence keys"
::= { alarms 4 }
noWirelessChannelAvailable OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
noWirelessChannelAvailable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { alarms 5 }
wirelessLinkDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { alarms 6 }
dataPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { alarms 7 }
dataPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { alarms 9 }
incompatibleMasterAndSlave OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleProductVariants(1),
differentSoftwareVersionsRunning(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { alarms 10 }
tDDSynchronizationStatus OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
holdover(1),
holdoverNotConnected(2),
acquiringLock(3),
noTimingReference(4),
timingSystemNotConnected(5),
initialising(6),
clusterTimingMaster(7),
tDDSyncNotActive(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An alarm value (displayed in red) indicates that one of
the following conditions has not been met (i) An external
timing system is connected or internal timing has been
configured. (ii) The timing system is providing a useable
reference. (iii) The ODU is locked to this reference."
::= { alarms 11 }
tDDSynchronizationAlarm OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
notSynchronized(1),
timingSystemFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { alarms 13 }
linkModeOptimizationMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
linkModeOptimizationMismatch(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { alarms 14 }
capacityLicenseMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local and remote units have different licensed
capacity and/or the full capacity trial has been
activated at only one unit. The wireless link is
operating at the capacity of the lowest capacity unit"
::= { alarms 16 }
-- Smtp group attribute definitions
--
sMTPEmailAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Simple Mail Transfer Protocol is used to send equipment
alerts via email to a specified email address. This
utility can only be configured by the system
administrator"
::= { smtp 1 }
sMTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the SMTP server"
::= { smtp 2 }
sMTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port number of the SMTP server"
::= { smtp 3 }
sMTPSourceEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'from' email address used when constructing the
automatically generated e-mail message"
::= { smtp 4 }
sMTPDestinationEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'to' email address used when constructing the
automatically generated e-mail message"
::= { smtp 5 }
sMTPEnabledMessages OBJECT-TYPE
SYNTAX BITS {
telecomsChannelUpDown(1),
unknown6(2),
dataPortUpDown(3),
enabledDiagnosticAlarms(4),
dFSImpulseInterference(5),
channelChange(6),
wirelessLinkUpDown(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SMTP messages the unit will send"
::= { smtp 6 }
-- SnmpControl group attribute definitions
--
sNMPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number used to access the SNMP MIB (i.e.
Gets and Sets) (default = 161). NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 1 }
sNMPCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP community string. NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 2 }
sNMPTrapTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPTrapTable."
::= { snmpControl 3 }
sNMPTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP protocol version to use for SNMP Traps. NB: A
system reboot is required to activate changes to this
attribute"
::= { snmpControl 5 }
sNMPEnabledTraps OBJECT-TYPE
SYNTAX BITS {
unknown8(0),
dataPortUpDown(1),
authenticationFailure(2),
enabledDiagnosticAlarms(3),
dFSImpulseInterference(4),
channelChange(5),
wirelessLinkUpDown(6),
coldStart(7),
telecomsChannelUpDown(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SNMP Traps the unit will send"
::= { snmpControl 6 }
enabledDiagnosticAlarms OBJECT-TYPE
SYNTAX BITS {
incompatibleMasterAndSlave(0),
incompatibleRegionCodes(1),
unknown6(2),
unknown5(3),
unitOutOfCalibration(4),
installArmState(5),
installStatus(6),
regionCode(7),
telecomsChannelStatus(8),
unknown15(9),
dataPortStatus(10),
dataPortDisabledWarning(11),
wirelessLinkDisabledWarning(12),
sNTPSynchronizationFailed(13),
noWirelessChannelAvailable(14),
dataPortConfigurationMismatch(15),
syslogClientDisabledWarning(16),
licensedCapacityMismatch(17),
syslogLocalWrapped(18),
syslogLocalNearlyFull(19),
syslogLocalEnableDisable(20),
linkModeOptimizationMismatch(21),
tDDSynchronizationAlarm(22),
telecomsChannelLoopback(23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which individual diagnostic alarms are enabled.
The unit may be configured to generate SNMP traps and/or
SMTP email alerts for these enabled alarms by selecting
'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps'
and/or 'SMTP Enabled Messages' attributes"
::= { snmpControl 7 }
sNMPSendAllTrapsAtStartup OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether cleared traps are reported at start-up
as well as raised traps. Only enabled traps will be
reported. NB: Traps corresponding to transient events
(i.e. not associated with an alarm or status value) are
only sent when required and not at start-up."
::= { snmpControl 8 }
-- SNMPTrapTable group attribute definitions
--
sNMPTrapTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap value, used to index the SNMPTrapTable."
::= { sNMPTrapTableEntry 1 }
sNMPTrapIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address to which all SNMP Traps are sent. An IP
Address of 0.0.0.0 disables all TRAP generation. NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 2 }
sNMPTrapPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination port for SNMP Traps (default=162). A value
of 0 will disable the trap receiver. NB: A system reboot
is required to activate changes to this attribute."
::= { sNMPTrapTableEntry 3 }
-- Sntp group attribute definitions
--
sNTPState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNTP control state"
::= { sntp 1 }
sNTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of a valid SNTP server"
::= { sntp 2 }
sNTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number of the SNTP server. Defaults to port
123."
::= { sntp 3 }
sNTPPollInterval OBJECT-TYPE
SYNTAX INTEGER (60..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNTP server polling interval"
::= { sntp 4 }
sNTPSync OBJECT-TYPE
SYNTAX INTEGER {
noSync(0),
inSync(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { sntp 5 }
sNTPLastSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last SNTP sync time"
::= { sntp 6 }
systemClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock presented as local time"
::= { sntp 7 }
timeZone OBJECT-TYPE
SYNTAX INTEGER {
gmtMinus1200(0),
gmtMinus1130(1),
gmtMinus1100(2),
gmtMinus1030(3),
gmtMinus1000(4),
gmtMinus0930(5),
gmtMinus0900(6),
gmtMinus0830(7),
gmtMinus0800(8),
gmtMinus0730(9),
gmtMinus0700(10),
gmtMinus0630(11),
gmtMinus0600(12),
gmtMinus0530(13),
gmtMinus0500(14),
gmtMinus0430(15),
gmtMinus0400(16),
gmtMinus0330(17),
gmtMinus0300(18),
gmtMinus0230(19),
gmtMinus0200(20),
gmtMinus0130(21),
gmtMinus0100(22),
gmtMinus0030(23),
gmtZero(24),
gmtPlus0030(25),
gmtPlus0100(26),
gmtPlus0130(27),
gmtPlus0200(28),
gmtPlus0230(29),
gmtPlus0300(30),
gmtPlus0330(31),
gmtPlus0400(32),
gmtPlus0430(33),
gmtPlus0500(34),
gmtPlus0530(35),
gmtPlus0600(36),
gmtPlus0630(37),
gmtPlus0700(38),
gmtPlus0730(39),
gmtPlus0800(40),
gmtPlus0830(41),
gmtPlus0900(42),
gmtPlus0930(43),
gmtPlus1000(44),
gmtPlus1030(45),
gmtPlus1100(46),
gmtPlus1130(47),
gmtPlus1200(48),
gmtPlus1230(49),
gmtPlus1300(50)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time zone offsets from Greenwich Mean Time (GMT)"
::= { sntp 8 }
daylightSaving OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Daylight Saving Time"
::= { sntp 9 }
-- Reset group attribute definitions
--
systemReset OBJECT-TYPE
SYNTAX INTEGER {
running(0),
consoleReboot(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to '1' will cause a system
reboot. NB: a system reboot will apply any pending new
settings held in memory"
::= { reset 1 }
-- Versions group attribute definitions
--
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current software version"
::= { versions 1 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform version"
::= { versions 2 }
secondarySoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secondary software version, used when the primary
software image is invalid or erased"
::= { versions 3 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boot code software version"
::= { versions 4 }
-- PubStats group attribute definitions
--
receiveDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 1 }
transmitDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 2 }
aggregateDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 3 }
wirelessLinkAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability calculated since the last reset of the
system counters, as a percentage multiplied by 10000 to
give four decimal places of precision"
::= { pubStats 4 }
wirelessLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(0),
registering(1),
acquiring(2),
searching(3),
radarCAC(4),
initialising(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the wireless link"
::= { pubStats 5 }
byteErrorRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reciprocal of the byte error ratio calculated since the
last reset of the system counters"
::= { pubStats 6 }
receiveModulationModeDetail OBJECT-TYPE
SYNTAX INTEGER {
runningAtMaximumReceiveMode(0),
runningAtUserConfiguredMaxModulationMode(1),
restrictedBecauseInstallationIsArmed(2),
restrictedBecauseOfByteErrorsOnTheWirelessLink(3),
restrictedBecauseTheLinkParametersAreUpdating(4),
restrictedBecauseChannelChangeIsInProgress(5),
restrictedDueToTheLowEthernetLinkSpeed(6),
runningAtMaximumReceiveModeForChannelBandwidth(7),
limitedByTheWirelessConditions(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the current receive modulation mode"
::= { pubStats 7 }
-- Encryption group attribute definitions
--
encryptionAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
none(0),
aESRijndael(1),
aES256bitRijndael(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Encryption Algorithm used by the wireless link. NB:
A system reboot is required to activate changes to this
attribute. NB: The same Encryption Algorithm must be
configured at BOTH ends of the link for it to function
correctly"
::= { encryption 1 }
-- TDDControl group attribute definitions
--
tDDSynchronizationMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TDD Synchronization Mode selection"
::= { tDDControl 1 }
-- AAAControl group attribute definitions
--
userTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the userTable"
::= { aAAControl 1 }
-- UserTable group attribute definitions
--
userTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the userTable."
::= { userTableEntry 1 }
userName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User name which must be entered, along with the
appropriate password, in order to gain access to the
system."
::= { userTableEntry 2 }
userRole OBJECT-TYPE
SYNTAX INTEGER {
readOnly(0),
systemAdministrator(1),
securityOfficer(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Role of the selected user. A Security Officer has access
to and can modify all settings. A System Administrator
has access to and can modify all non-security settings. A
Read Only user can view settings, but cannot make any
changes."
::= { userTableEntry 3 }
userEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable / Disable the selected user"
::= { userTableEntry 4 }
userPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User password, which must be entered in order to gain
access to the system."
::= { userTableEntry 5 }
-- SyslogControl group attribute definitions
--
syslogClient OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { syslogControl 1 }
syslogState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { syslogControl 2 }
-- Supplementary group attribute definitions
--
longitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The longitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 1 }
latitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The latitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 2 }
altitude OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The altitude of the unit, measured in metres. This
object is set by the SNMP manager and has no internal
function."
::= { supplementary 3 }
-- Enterprise NOTIFICATION definitions
--
channelChangeTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "The PTP radio has changed wireless channel.
This has been caused by either
i) mandatory radar avoidance,
a DFS impulsive interference event will also be
detected,
or
ii) Dynamic Spectrum Optimization, (DSO)
DSO improves link performance by selecting the
most appropriate transmit and receive channels
with the lowest level of interference."
::= { ptpTrapPrefix 1 }
dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "DFS impulsive interference detected event"
::= { ptpTrapPrefix 2 }
dataPortStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortStatus }
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 3 }
telecomsChannelStatusTrap NOTIFICATION-TYPE
OBJECTS { telecomsChannelStatus }
STATUS current
DESCRIPTION
"Current status of telecoms channel. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 4 }
telecomsLoopbackTrap NOTIFICATION-TYPE
OBJECTS { telecomsLoopback }
STATUS current
DESCRIPTION
"The loopback status of telecoms channel. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. When
applying a wireless loopback, please ensure that the
other end of the link has a loopback setting of 'None'.
NB: a change of state may generate an SNMP trap and/or
SMTP email alert"
::= { ptpTrapPrefix 6 }
regionCodeTrap NOTIFICATION-TYPE
OBJECTS { regionCode }
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted licence key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 8 }
installStatusTrap NOTIFICATION-TYPE
OBJECTS { installStatus }
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { ptpTrapPrefix 9 }
installArmStateTrap NOTIFICATION-TYPE
OBJECTS { installArmState }
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a value
other than 'disarmed' on startup, or a change of state
during operation may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 10 }
unitOutOfCalibrationTrap NOTIFICATION-TYPE
OBJECTS { unitOutOfCalibration }
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { ptpTrapPrefix 11 }
incompatibleRegionCodesTrap NOTIFICATION-TYPE
OBJECTS { incompatibleRegionCodes }
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible licence keys"
::= { ptpTrapPrefix 14 }
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
OBJECTS { noWirelessChannelAvailable }
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { ptpTrapPrefix 15 }
wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { wirelessLinkDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { ptpTrapPrefix 16 }
dataPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { dataPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { ptpTrapPrefix 17 }
dataPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { dataPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { ptpTrapPrefix 19 }
incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE
OBJECTS { incompatibleMasterAndSlave }
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 20 }
sNTPSyncTrap NOTIFICATION-TYPE
OBJECTS { sNTPSync }
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 21 }
tDDSynchronizationAlarmTrap NOTIFICATION-TYPE
OBJECTS { tDDSynchronizationAlarm }
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { ptpTrapPrefix 22 }
linkModeOptimizationMismatchTrap NOTIFICATION-TYPE
OBJECTS { linkModeOptimizationMismatch }
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { ptpTrapPrefix 25 }
capacityLicenseMismatchTrap NOTIFICATION-TYPE
OBJECTS { capacityLicenseMismatch }
STATUS current
DESCRIPTION
"The local and remote units have different licensed
capacity and/or the full capacity trial has been
activated at only one unit. The wireless link is
operating at the capacity of the lowest capacity unit"
::= { ptpTrapPrefix 27 }
syslogStateTrap NOTIFICATION-TYPE
OBJECTS { syslogState }
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { ptpTrapPrefix 30 }
syslogLocalNearlyFullTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log is nearly full (90%)"
::= { ptpTrapPrefix 31 }
syslogLocalWrappedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log has wrapped"
::= { ptpTrapPrefix 32 }
syslogClientTrap NOTIFICATION-TYPE
OBJECTS { syslogClient }
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { ptpTrapPrefix 33 }
END