mibs/MIBS/ceraos/MWRM-PM-MIB

5217 lines
166 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--MWRM-PM-MIB VERSION 1.8.3.1
--MWRM (MicroWave-Radio-MIB)
MWRM-PM-MIB DEFINITIONS ::= BEGIN
IMPORTS
-- Ipv6Address FROM IPV6-TC
-- Counter, enterprises, Gauge, IpAddress FROM RFC1155-SMI
Counter32, enterprises, Gauge32, IpAddress FROM SNMPv2-SMI
DisplayString, ifIndex FROM RFC1213-MIB
RowStatus FROM SNMPv2-TC
MacAddress FROM SNMPv2-TC
OBJECT-TYPE FROM SNMPv2-SMI
TRAP-TYPE FROM RFC-1215
EnableDisable FROM MWRM-UNIT-MIB
EnableDisableSMI2 FROM MWRM-UNIT-MIB
OffOn FROM MWRM-UNIT-MIB
MetricImperial FROM MWRM-UNIT-MIB
AllowedNotAllowed FROM MWRM-UNIT-MIB
ProgressStatus FROM MWRM-UNIT-MIB
Severity FROM MWRM-UNIT-MIB
NoYes FROM MWRM-UNIT-MIB
DownUp FROM MWRM-UNIT-MIB
TrailIfType FROM MWRM-UNIT-MIB
PmTableType FROM MWRM-UNIT-MIB
RateMbps FROM MWRM-UNIT-MIB
HalfFull FROM MWRM-UNIT-MIB
BerLevel FROM MWRM-UNIT-MIB
SignalLevel FROM MWRM-UNIT-MIB
LoopbackType FROM MWRM-UNIT-MIB
QueueName FROM MWRM-UNIT-MIB
RadioId FROM MWRM-UNIT-MIB
RfuId FROM MWRM-UNIT-MIB
SwCommand FROM MWRM-UNIT-MIB
TrailProtectedType FROM MWRM-UNIT-MIB
ClockSrc FROM MWRM-UNIT-MIB
SlotId FROM MWRM-UNIT-MIB
Integrity FROM MWRM-UNIT-MIB
GreenYellow FROM MWRM-UNIT-MIB
InputSeverity FROM MWRM-UNIT-MIB
SwCommandTimer FROM MWRM-UNIT-MIB
genEquipRadioCfgRadioId FROM MWRM-RADIO-MIB;
microwave-radio OBJECT IDENTIFIER ::= { enterprises 2281 }
genEquip OBJECT IDENTIFIER ::= { microwave-radio 10}
genEquipUnit OBJECT IDENTIFIER ::= { genEquip 1}
-- Performance Monitoring Tables
genEquipPM OBJECT IDENTIFIER ::= {genEquip 6}
genEquipPmRfu OBJECT IDENTIFIER ::= {genEquipPM 1}
genEquipPmRfuCommon OBJECT IDENTIFIER ::= {genEquipPmRfu 1}
genEquipPmRfuCommonSL15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRfuCommonSL15minEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the RFU Signal Level PM data."
::= { genEquipPmRfuCommon 1 }
genEquipPmRfuCommonSL15minEntry OBJECT-TYPE
SYNTAX GenEquipPmRfuCommonSL15minEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the data of the RFU SL PM."
INDEX { genEquipPmRfuCommonSL15minId }
::= { genEquipPmRfuCommonSL15minTable 1 }
GenEquipPmRfuCommonSL15minEntry ::=
SEQUENCE {
genEquipPmRfuCommonSL15minId INTEGER,
genEquipPmRfuCommonSL15minIfIndex INTEGER,
genEquipPmRfuCommonSL15minTimeAndDate DisplayString,
genEquipPmRfuCommonSL15minMinRsl INTEGER,
genEquipPmRfuCommonSL15minMaxRsl INTEGER,
genEquipPmRfuCommonSL15minRslExceed1 INTEGER,
genEquipPmRfuCommonSL15minRslExceed2 INTEGER,
genEquipPmRfuCommonSL15minMinTsl INTEGER,
genEquipPmRfuCommonSL15minMaxTsl INTEGER,
genEquipPmRfuCommonSL15minTslExceed INTEGER,
genEquipPmRfuCommonSL15minIDF Integrity
}
genEquipPmRfuCommonSL15minId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmRfuCommonSL15minEntry 1 }
genEquipPmRfuCommonSL15minIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmRfuCommonSL15minEntry 2 }
genEquipPmRfuCommonSL15minTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Time and date for the specific PM."
::= { genEquipPmRfuCommonSL15minEntry 3 }
genEquipPmRfuCommonSL15minMinRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the minimum RSL value."
::= { genEquipPmRfuCommonSL15minEntry 4 }
genEquipPmRfuCommonSL15minMaxRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the maximum RSL value."
::= { genEquipPmRfuCommonSL15minEntry 5 }
genEquipPmRfuCommonSL15minRslExceed1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 1."
::= { genEquipPmRfuCommonSL15minEntry 6 }
genEquipPmRfuCommonSL15minRslExceed2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 2."
::= { genEquipPmRfuCommonSL15minEntry 7 }
genEquipPmRfuCommonSL15minMinTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Min TSL value."
::= { genEquipPmRfuCommonSL15minEntry 8 }
genEquipPmRfuCommonSL15minMaxTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Max TSL value."
::= { genEquipPmRfuCommonSL15minEntry 9 }
genEquipPmRfuCommonSL15minTslExceed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds TSL exceeded the threshold"
::= { genEquipPmRfuCommonSL15minEntry 10 }
genEquipPmRfuCommonSL15minIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmRfuCommonSL15minEntry 11 }
-- SL 15 min CURRENT table --
genEquipPmRfuCommonSL15minCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRfuCommonSL15minCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the RFU Signal Level PM data for the current 15 min. interval."
::= { genEquipPmRfuCommon 2 }
genEquipPmRfuCommonSL15minCurrEntry OBJECT-TYPE
SYNTAX GenEquipPmRfuCommonSL15minCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the data of the Rfu SL PM."
INDEX { genEquipPmRfuCommonSL15minCurrId }
::= { genEquipPmRfuCommonSL15minCurrTable 1 }
GenEquipPmRfuCommonSL15minCurrEntry ::=
SEQUENCE {
genEquipPmRfuCommonSL15minCurrId INTEGER,
genEquipPmRfuCommonSL15minCurrIfIndex INTEGER,
genEquipPmRfuCommonSL15minCurrTimeAndDate DisplayString,
genEquipPmRfuCommonSL15minCurrMinRsl INTEGER,
genEquipPmRfuCommonSL15minCurrMaxRsl INTEGER,
genEquipPmRfuCommonSL15minCurrRslExceed1 INTEGER,
genEquipPmRfuCommonSL15minCurrRslExceed2 INTEGER,
genEquipPmRfuCommonSL15minCurrMinTsl INTEGER,
genEquipPmRfuCommonSL15minCurrMaxTsl INTEGER,
genEquipPmRfuCommonSL15minCurrTslExceed INTEGER,
genEquipPmRfuCommonSL15minCurrIDF Integrity
}
genEquipPmRfuCommonSL15minCurrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmRfuCommonSL15minCurrEntry 1 }
genEquipPmRfuCommonSL15minCurrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmRfuCommonSL15minCurrEntry 2 }
genEquipPmRfuCommonSL15minCurrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Time and date for the specific PM."
::= { genEquipPmRfuCommonSL15minCurrEntry 3 }
genEquipPmRfuCommonSL15minCurrMinRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the minimum RSL value."
::= { genEquipPmRfuCommonSL15minCurrEntry 4 }
genEquipPmRfuCommonSL15minCurrMaxRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the maximum RSL value."
::= { genEquipPmRfuCommonSL15minCurrEntry 5 }
genEquipPmRfuCommonSL15minCurrRslExceed1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 1."
::= { genEquipPmRfuCommonSL15minCurrEntry 6 }
genEquipPmRfuCommonSL15minCurrRslExceed2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 2."
::= { genEquipPmRfuCommonSL15minCurrEntry 7 }
genEquipPmRfuCommonSL15minCurrMinTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Min TSL value."
::= { genEquipPmRfuCommonSL15minCurrEntry 8 }
genEquipPmRfuCommonSL15minCurrMaxTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Max TSL value."
::= { genEquipPmRfuCommonSL15minCurrEntry 9 }
genEquipPmRfuCommonSL15minCurrTslExceed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds TSL exceeded the threshold"
::= { genEquipPmRfuCommonSL15minCurrEntry 10 }
genEquipPmRfuCommonSL15minCurrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the current interval.
integrity(0), nointegrity(1)."
::= { genEquipPmRfuCommonSL15minCurrEntry 11 }
-- PM Tables for SL 24 hour intervals
genEquipPmRfuCommonSL24hrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRfuCommonSL24hrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the RFU Signal Level 24 hr PM data."
::= { genEquipPmRfuCommon 3 }
genEquipPmRfuCommonSL24hrEntry OBJECT-TYPE
SYNTAX GenEquipPmRfuCommonSL24hrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the data of the RFU SL PM."
INDEX { genEquipPmRfuCommonSL24hrId }
::= { genEquipPmRfuCommonSL24hrTable 1 }
GenEquipPmRfuCommonSL24hrEntry ::=
SEQUENCE {
genEquipPmRfuCommonSL24hrId INTEGER,
genEquipPmRfuCommonSL24hrIfIndex INTEGER,
genEquipPmRfuCommonSL24hrTimeAndDate DisplayString,
genEquipPmRfuCommonSL24hrMinRsl INTEGER,
genEquipPmRfuCommonSL24hrMaxRsl INTEGER,
genEquipPmRfuCommonSL24hrRslExceed1 INTEGER,
genEquipPmRfuCommonSL24hrRslExceed2 INTEGER,
genEquipPmRfuCommonSL24hrMinTsl INTEGER,
genEquipPmRfuCommonSL24hrMaxTsl INTEGER,
genEquipPmRfuCommonSL24hrTslExceed INTEGER,
genEquipPmRfuCommonSL24hrIDF Integrity
}
genEquipPmRfuCommonSL24hrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmRfuCommonSL24hrEntry 1 }
genEquipPmRfuCommonSL24hrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmRfuCommonSL24hrEntry 2 }
genEquipPmRfuCommonSL24hrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmRfuCommonSL24hrEntry 3 }
genEquipPmRfuCommonSL24hrMinRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the min RSL value."
::= { genEquipPmRfuCommonSL24hrEntry 4 }
genEquipPmRfuCommonSL24hrMaxRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the max RSL value."
::= { genEquipPmRfuCommonSL24hrEntry 5 }
genEquipPmRfuCommonSL24hrRslExceed1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 1."
::= { genEquipPmRfuCommonSL24hrEntry 6 }
genEquipPmRfuCommonSL24hrRslExceed2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 2."
::= { genEquipPmRfuCommonSL24hrEntry 7 }
genEquipPmRfuCommonSL24hrMinTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Min TSL value."
::= { genEquipPmRfuCommonSL24hrEntry 8 }
genEquipPmRfuCommonSL24hrMaxTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Max TSL value."
::= { genEquipPmRfuCommonSL24hrEntry 9 }
genEquipPmRfuCommonSL24hrTslExceed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded the threshold"
::= { genEquipPmRfuCommonSL24hrEntry 10 }
genEquipPmRfuCommonSL24hrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmRfuCommonSL24hrEntry 11 }
-- SL 24 HR CURRENT table --
genEquipPmRfuCommonSL24hrCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRfuCommonSL24hrCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the RFU Signal Level PM data for the current 24 hour interval."
::= { genEquipPmRfuCommon 4 }
genEquipPmRfuCommonSL24hrCurrEntry OBJECT-TYPE
SYNTAX GenEquipPmRfuCommonSL24hrCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the data of the RFU SL PM."
INDEX { genEquipPmRfuCommonSL24hrCurrId }
::= { genEquipPmRfuCommonSL24hrCurrTable 1 }
GenEquipPmRfuCommonSL24hrCurrEntry ::=
SEQUENCE {
genEquipPmRfuCommonSL24hrCurrId INTEGER,
genEquipPmRfuCommonSL24hrCurrIfIndex INTEGER,
genEquipPmRfuCommonSL24hrCurrTimeAndDate DisplayString,
genEquipPmRfuCommonSL24hrCurrMinRsl INTEGER,
genEquipPmRfuCommonSL24hrCurrMaxRsl INTEGER,
genEquipPmRfuCommonSL24hrCurrRslExceed1 INTEGER,
genEquipPmRfuCommonSL24hrCurrRslExceed2 INTEGER,
genEquipPmRfuCommonSL24hrCurrMinTsl INTEGER,
genEquipPmRfuCommonSL24hrCurrMaxTsl INTEGER,
genEquipPmRfuCommonSL24hrCurrTslExceed INTEGER,
genEquipPmRfuCommonSL24hrCurrIDF Integrity
}
genEquipPmRfuCommonSL24hrCurrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmRfuCommonSL24hrCurrEntry 1 }
genEquipPmRfuCommonSL24hrCurrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmRfuCommonSL24hrCurrEntry 2 }
genEquipPmRfuCommonSL24hrCurrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmRfuCommonSL24hrCurrEntry 3 }
genEquipPmRfuCommonSL24hrCurrMinRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the min RSL value."
::= { genEquipPmRfuCommonSL24hrCurrEntry 4 }
genEquipPmRfuCommonSL24hrCurrMaxRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Max RSL value."
::= { genEquipPmRfuCommonSL24hrCurrEntry 5 }
genEquipPmRfuCommonSL24hrCurrRslExceed1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 1."
::= { genEquipPmRfuCommonSL24hrCurrEntry 6 }
genEquipPmRfuCommonSL24hrCurrRslExceed2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 2."
::= { genEquipPmRfuCommonSL24hrCurrEntry 7 }
genEquipPmRfuCommonSL24hrCurrMinTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Min TSL value."
::= { genEquipPmRfuCommonSL24hrCurrEntry 8 }
genEquipPmRfuCommonSL24hrCurrMaxTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Max TSL value."
::= { genEquipPmRfuCommonSL24hrCurrEntry 9 }
genEquipPmRfuCommonSL24hrCurrTslExceed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds TSL exceeded the threshold"
::= { genEquipPmRfuCommonSL24hrCurrEntry 10 }
genEquipPmRfuCommonSL24hrCurrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmRfuCommonSL24hrCurrEntry 11 }
-- PM for Radio Aggregate - 15 min intervals
genEquipPmTraffic OBJECT IDENTIFIER ::= {genEquipPM 2}
genEquipPmTrafficRadioAgg15minTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficRadioAgg15minEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
::= { genEquipPmTraffic 1 }
genEquipPmTrafficRadioAgg15minEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficRadioAgg15minEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
INDEX { genEquipPmTrafficRadioAgg15minId }
::= { genEquipPmTrafficRadioAgg15minTable 1 }
GenEquipPmTrafficRadioAgg15minEntry ::=
SEQUENCE {
genEquipPmTrafficRadioAgg15minId INTEGER,
genEquipPmTrafficRadioAgg15minIfIndex INTEGER,
genEquipPmTrafficRadioAgg15minTimeAndDate DisplayString,
genEquipPmTrafficRadioAgg15minES INTEGER,
genEquipPmTrafficRadioAgg15minSES INTEGER,
genEquipPmTrafficRadioAgg15minUAS INTEGER,
genEquipPmTrafficRadioAgg15minBBE INTEGER,
genEquipPmTrafficRadioAgg15minIDF Integrity
}
genEquipPmTrafficRadioAgg15minId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmTrafficRadioAgg15minEntry 1 }
genEquipPmTrafficRadioAgg15minIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmTrafficRadioAgg15minEntry 2 }
genEquipPmTrafficRadioAgg15minTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmTrafficRadioAgg15minEntry 3 }
genEquipPmTrafficRadioAgg15minES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the ES value."
::= { genEquipPmTrafficRadioAgg15minEntry 4 }
genEquipPmTrafficRadioAgg15minSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the SES value."
::= { genEquipPmTrafficRadioAgg15minEntry 5 }
genEquipPmTrafficRadioAgg15minUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the UAS value."
::= { genEquipPmTrafficRadioAgg15minEntry 6 }
genEquipPmTrafficRadioAgg15minBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the BBE value."
::= { genEquipPmTrafficRadioAgg15minEntry 7 }
genEquipPmTrafficRadioAgg15minIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmTrafficRadioAgg15minEntry 8 }
-- PM for Radio Agg. - 15min - Current interval
genEquipPmTrafficRadioAgg15minCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficRadioAgg15minCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
::= { genEquipPmTraffic 2 }
genEquipPmTrafficRadioAgg15minCurrEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficRadioAgg15minCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
INDEX { genEquipPmTrafficRadioAgg15minCurrId }
::= { genEquipPmTrafficRadioAgg15minCurrTable 1 }
GenEquipPmTrafficRadioAgg15minCurrEntry ::=
SEQUENCE {
genEquipPmTrafficRadioAgg15minCurrId INTEGER,
genEquipPmTrafficRadioAgg15minCurrIfIndex INTEGER,
genEquipPmTrafficRadioAgg15minCurrTimeAndDate DisplayString,
genEquipPmTrafficRadioAgg15minCurrES INTEGER,
genEquipPmTrafficRadioAgg15minCurrSES INTEGER,
genEquipPmTrafficRadioAgg15minCurrUAS INTEGER,
genEquipPmTrafficRadioAgg15minCurrBBE INTEGER,
genEquipPmTrafficRadioAgg15minCurrIDF Integrity
}
genEquipPmTrafficRadioAgg15minCurrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmTrafficRadioAgg15minCurrEntry 1 }
genEquipPmTrafficRadioAgg15minCurrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmTrafficRadioAgg15minCurrEntry 2 }
genEquipPmTrafficRadioAgg15minCurrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 3 }
genEquipPmTrafficRadioAgg15minCurrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the ES value."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 4 }
genEquipPmTrafficRadioAgg15minCurrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the SES value."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 5 }
genEquipPmTrafficRadioAgg15minCurrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the UAS value."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 6 }
genEquipPmTrafficRadioAgg15minCurrBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the BBE value."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 7 }
genEquipPmTrafficRadioAgg15minCurrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmTrafficRadioAgg15minCurrEntry 8 }
-- PM for Radio Aggregate - 24 hours intervals
genEquipPmTrafficRadioAgg24hrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficRadioAgg24hrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
::= { genEquipPmTraffic 3 }
genEquipPmTrafficRadioAgg24hrEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficRadioAgg24hrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
INDEX { genEquipPmTrafficRadioAgg24hrId }
::= { genEquipPmTrafficRadioAgg24hrTable 1 }
GenEquipPmTrafficRadioAgg24hrEntry ::=
SEQUENCE {
genEquipPmTrafficRadioAgg24hrId INTEGER,
genEquipPmTrafficRadioAgg24hrIfIndex INTEGER,
genEquipPmTrafficRadioAgg24hrTimeAndDate DisplayString,
genEquipPmTrafficRadioAgg24hrES INTEGER,
genEquipPmTrafficRadioAgg24hrSES INTEGER,
genEquipPmTrafficRadioAgg24hrUAS INTEGER,
genEquipPmTrafficRadioAgg24hrBBE INTEGER,
genEquipPmTrafficRadioAgg24hrIDF Integrity
}
genEquipPmTrafficRadioAgg24hrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmTrafficRadioAgg24hrEntry 1 }
genEquipPmTrafficRadioAgg24hrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmTrafficRadioAgg24hrEntry 2 }
genEquipPmTrafficRadioAgg24hrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmTrafficRadioAgg24hrEntry 3 }
genEquipPmTrafficRadioAgg24hrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the ES value."
::= { genEquipPmTrafficRadioAgg24hrEntry 4 }
genEquipPmTrafficRadioAgg24hrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the SES value."
::= { genEquipPmTrafficRadioAgg24hrEntry 5 }
genEquipPmTrafficRadioAgg24hrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the UAS value."
::= { genEquipPmTrafficRadioAgg24hrEntry 6 }
genEquipPmTrafficRadioAgg24hrBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the BBE value."
::= { genEquipPmTrafficRadioAgg24hrEntry 7 }
genEquipPmTrafficRadioAgg24hrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the interval.
integrity(0), nointegrity(1)."
::= { genEquipPmTrafficRadioAgg24hrEntry 8 }
-- PM for Radio Agg. - 24hr - Current interval
genEquipPmTrafficRadioAgg24hrCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficRadioAgg24hrCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
::= { genEquipPmTraffic 4 }
genEquipPmTrafficRadioAgg24hrCurrEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficRadioAgg24hrCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data for all 15 min intervals."
INDEX { genEquipPmTrafficRadioAgg24hrCurrId }
::= { genEquipPmTrafficRadioAgg24hrCurrTable 1 }
GenEquipPmTrafficRadioAgg24hrCurrEntry ::=
SEQUENCE {
genEquipPmTrafficRadioAgg24hrCurrId INTEGER,
genEquipPmTrafficRadioAgg24hrCurrIfIndex INTEGER,
genEquipPmTrafficRadioAgg24hrCurrTimeAndDate DisplayString,
genEquipPmTrafficRadioAgg24hrCurrES INTEGER,
genEquipPmTrafficRadioAgg24hrCurrSES INTEGER,
genEquipPmTrafficRadioAgg24hrCurrUAS INTEGER,
genEquipPmTrafficRadioAgg24hrCurrBBE INTEGER,
genEquipPmTrafficRadioAgg24hrCurrIDF Integrity
}
genEquipPmTrafficRadioAgg24hrCurrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 1 }
genEquipPmTrafficRadioAgg24hrCurrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 2 }
genEquipPmTrafficRadioAgg24hrCurrTimeAndDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time and date for the specific PM."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 3 }
genEquipPmTrafficRadioAgg24hrCurrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the ES value."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 4 }
genEquipPmTrafficRadioAgg24hrCurrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the SES value."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 5 }
genEquipPmTrafficRadioAgg24hrCurrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the UAS value."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 6 }
genEquipPmTrafficRadioAgg24hrCurrBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the BBE value."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 7 }
genEquipPmTrafficRadioAgg24hrCurrIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the IDF (Invalid Data Flag) of the current interval.
integrity(0), nointegrity(1)."
::= { genEquipPmTrafficRadioAgg24hrCurrEntry 8 }
-- New PM tables - Add PM Table Type to the tables as index.
genEquipPmAll OBJECT IDENTIFIER ::= {genEquipPM 3}
genEquipPmClear OBJECT-TYPE
SYNTAX OffOn
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear All values for PM tables."
::= { genEquipPmAll 1 }
-- Signal Level PM Group
genEquipPmTrafficSL OBJECT IDENTIFIER ::= {genEquipPmAll 2}
genEquipPmTrafficSLTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficSLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the RFU Signal Level PM data."
::= { genEquipPmTrafficSL 1 }
genEquipPmTrafficSLEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficSLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the data of the RFU signal level PM."
INDEX { genEquipPmTrafficSLPmType, genEquipPmTrafficSLId, genEquipPmTrafficSLInterval }
::= { genEquipPmTrafficSLTable 1 }
GenEquipPmTrafficSLEntry ::=
SEQUENCE {
genEquipPmTrafficSLPmType PmTableType,
genEquipPmTrafficSLId RfuId,
genEquipPmTrafficSLInterval INTEGER,
genEquipPmTrafficSLMinRsl INTEGER,
genEquipPmTrafficSLMaxRsl INTEGER,
genEquipPmTrafficSLRslExceed1 INTEGER,
genEquipPmTrafficSLRslExceed2 INTEGER,
genEquipPmTrafficSLMinTsl INTEGER,
genEquipPmTrafficSLMaxTsl INTEGER,
genEquipPmTrafficSLTslExceed INTEGER,
genEquipPmTrafficSLIDF Integrity
}
genEquipPmTrafficSLPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmTrafficSLEntry 1 }
genEquipPmTrafficSLId OBJECT-TYPE
SYNTAX RfuId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmTrafficSLEntry 2 }
genEquipPmTrafficSLInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific PM Interval"
::= { genEquipPmTrafficSLEntry 3 }
genEquipPmTrafficSLMinRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the min RSL value."
::= { genEquipPmTrafficSLEntry 4 }
genEquipPmTrafficSLMaxRsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the max RSL value."
::= { genEquipPmTrafficSLEntry 5 }
genEquipPmTrafficSLRslExceed1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 1."
::= { genEquipPmTrafficSLEntry 6 }
genEquipPmTrafficSLRslExceed2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds RSL exceeded threshold number 2."
::= { genEquipPmTrafficSLEntry 7 }
genEquipPmTrafficSLMinTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Minimum TSL value."
::= { genEquipPmTrafficSLEntry 8 }
genEquipPmTrafficSLMaxTsl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the Maximum TSL value."
::= { genEquipPmTrafficSLEntry 9 }
genEquipPmTrafficSLTslExceed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of seconds TSL exceeded the threshold"
::= { genEquipPmTrafficSLEntry 10 }
genEquipPmTrafficSLIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmTrafficSLEntry 11 }
-- Aggregate PM Group
genEquipPmTrafficAggregate OBJECT IDENTIFIER ::= {genEquipPmAll 3}
genEquipPmTrafficAggTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrafficAggEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data."
::= { genEquipPmTrafficAggregate 1 }
genEquipPmTrafficAggEntry OBJECT-TYPE
SYNTAX GenEquipPmTrafficAggEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table indicates the Radio Aggregate PM data."
INDEX { genEquipPmTrafficAggPmType, ifIndex, genEquipPmTrafficAggInterval }
::= { genEquipPmTrafficAggTable 1 }
GenEquipPmTrafficAggEntry ::=
SEQUENCE {
genEquipPmTrafficAggPmType PmTableType,
genEquipPmTrafficAggInterval INTEGER,
genEquipPmTrafficAggES INTEGER,
genEquipPmTrafficAggSES INTEGER,
genEquipPmTrafficAggUAS INTEGER,
genEquipPmTrafficAggBBE INTEGER,
genEquipPmTrafficAggIDF Integrity
}
genEquipPmTrafficAggPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmTrafficAggEntry 1 }
genEquipPmTrafficAggInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific PM Interval"
::= { genEquipPmTrafficAggEntry 2 }
genEquipPmTrafficAggES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the ES value (Errored seconds)."
::= { genEquipPmTrafficAggEntry 3 }
genEquipPmTrafficAggSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the SES value (Severe Errored seconds)."
::= { genEquipPmTrafficAggEntry 4 }
genEquipPmTrafficAggUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the UAS value. (Unavailable Seconds)"
::= { genEquipPmTrafficAggEntry 5 }
genEquipPmTrafficAggBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the BBE value. (Background Block Error)"
::= { genEquipPmTrafficAggEntry 6 }
genEquipPmTrafficAggIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmTrafficAggEntry 7 }
-- Radio PM Group
genEquipPmRadio OBJECT IDENTIFIER ::= {genEquipPmAll 4}
-- Radio MRMC PM Group
genEquipPmRadioMRMC OBJECT IDENTIFIER ::= {genEquipPmRadio 1}
-- Radio MRMC PM Table
genEquipPmRadioMRMCTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioMRMCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The MRMC PM table"
::= { genEquipPmRadioMRMC 1 }
genEquipPmRadioMRMCEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioMRMCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The MRMC PM table"
INDEX { genEquipPmRadioMRMCPmType, genEquipPmRadioMRMCId, genEquipPmRadioMRMCInterval }
::= { genEquipPmRadioMRMCTable 1 }
GenEquipPmRadioMRMCEntry ::=
SEQUENCE {
genEquipPmRadioMRMCPmType PmTableType,
genEquipPmRadioMRMCId RadioId,
genEquipPmRadioMRMCInterval INTEGER,
genEquipPmRadioMRMCIfIndex INTEGER,
genEquipPmRadioMRMCMinProfile INTEGER,
genEquipPmRadioMRMCMaxProfile INTEGER,
genEquipPmRadioMRMCMinBitrate INTEGER,
genEquipPmRadioMRMCMaxBitrate INTEGER,
genEquipPmRadioMRMCMinTDMIf INTEGER,
genEquipPmRadioMRMCMaxTDMIf INTEGER,
genEquipPmRadioMRMCIDF Integrity
}
genEquipPmRadioMRMCPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmRadioMRMCEntry 1 }
genEquipPmRadioMRMCId OBJECT-TYPE
SYNTAX RadioId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific RFU"
::= { genEquipPmRadioMRMCEntry 2 }
genEquipPmRadioMRMCInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates an index of a specific PM Interval"
::= { genEquipPmRadioMRMCEntry 3 }
genEquipPmRadioMRMCIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface index of a specific RFU interface (as appears in the ifTable)"
::= { genEquipPmRadioMRMCEntry 4 }
genEquipPmRadioMRMCMinProfile OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum MRMC profile."
::= { genEquipPmRadioMRMCEntry 5 }
genEquipPmRadioMRMCMaxProfile OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum profile (Kbps) that was measured during the interva"
::= { genEquipPmRadioMRMCEntry 6 }
genEquipPmRadioMRMCMinBitrate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum MRMC nominal bitrate (Units are Kbps)"
::= { genEquipPmRadioMRMCEntry 7 }
genEquipPmRadioMRMCMaxBitrate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum MRMC nominal bitrate (Units are Kbps)"
::= { genEquipPmRadioMRMCEntry 8 }
genEquipPmRadioMRMCMinTDMIf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum number of allocated TDM channels"
::= { genEquipPmRadioMRMCEntry 9 }
genEquipPmRadioMRMCMaxTDMIf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum number of allocated TDM channels"
::= { genEquipPmRadioMRMCEntry 10 }
genEquipPmRadioMRMCIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioMRMCEntry 11 }
-- Radio E1/T1 PM Group
genEquipPmRadioTDM OBJECT IDENTIFIER ::= {genEquipPmRadio 2}
-- Radio E1/T1 TDM PM Table
genEquipPmRadioTDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioTDMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The PM table of logical TDM channels within the Radio link"
::= { genEquipPmRadioTDM 1 }
genEquipPmRadioTDMEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioTDMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The PM table of logical TDM channels within the Radio link"
INDEX { genEquipPmRadioTDMPmType, ifIndex, genEquipPmRadioTDMInterval }
::= { genEquipPmRadioTDMTable 1 }
GenEquipPmRadioTDMEntry ::=
SEQUENCE {
genEquipPmRadioTDMPmType PmTableType,
genEquipPmRadioTDMInterval INTEGER,
genEquipPmRadioTDMRadioUAS INTEGER,
genEquipPmRadioTDMIDF Integrity
}
genEquipPmRadioTDMPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmRadioTDMEntry 1 }
genEquipPmRadioTDMInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmRadioTDMEntry 2 }
genEquipPmRadioTDMRadioUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDM channel UAS (unavailable seconds)"
::= { genEquipPmRadioTDMEntry 3 }
genEquipPmRadioTDMIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioTDMEntry 4 }
-- Radio Ethernet PM Group
genEquipPmRadioEthernet OBJECT IDENTIFIER ::= {genEquipPmRadio 3}
-- Radio E1/T1 TDM PM Table
genEquipPmRadioEthernetTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioEthernetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet PMs on the radio link"
::= { genEquipPmRadioEthernet 1 }
genEquipPmRadioEthernetEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioEthernetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet PMs on the radio link"
INDEX { genEquipPmRadioEthernetPmType, ifIndex, genEquipPmRadioEthernetInterval }
::= { genEquipPmRadioEthernetTable 1 }
GenEquipPmRadioEthernetEntry ::=
SEQUENCE {
genEquipPmRadioEthernetPmType PmTableType,
genEquipPmRadioEthernetInterval INTEGER,
genEquipPmRadioEthernetFrameErrorRate INTEGER,
genEquipPmRadioEthernetPeakThroughput INTEGER,
genEquipPmRadioEthernetAverageThroughput INTEGER,
genEquipPmRadioEthernetExceedThroughput INTEGER,
genEquipPmRadioEthernetPeakCapacity INTEGER,
genEquipPmRadioEthernetAverageCapacity INTEGER,
genEquipPmRadioEthernetExceedCapacity INTEGER,
genEquipPmRadioEthernetPeakUtilization INTEGER,
genEquipPmRadioEthernetAverageUtilization INTEGER,
genEquipPmRadioEthernetExceedUtilization INTEGER,
genEquipPmRadioEthernetIDF Integrity
}
genEquipPmRadioEthernetPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmRadioEthernetEntry 1 }
genEquipPmRadioEthernetInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmRadioEthernetEntry 2 }
genEquipPmRadioEthernetFrameErrorRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Frame Error Rate PM"
::= { genEquipPmRadioEthernetEntry 3 }
genEquipPmRadioEthernetPeakThroughput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Peak throughput PM (Units are bits per second)"
::= { genEquipPmRadioEthernetEntry 4 }
genEquipPmRadioEthernetAverageThroughput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Average throughput PM (Units are bits per second)"
::= { genEquipPmRadioEthernetEntry 5 }
genEquipPmRadioEthernetExceedThroughput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Exceed throughput PM"
::= { genEquipPmRadioEthernetEntry 6 }
genEquipPmRadioEthernetPeakCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Peak capacity PM (in bps)"
::= { genEquipPmRadioEthernetEntry 7 }
genEquipPmRadioEthernetAverageCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Average capacity PM (in bps)"
::= { genEquipPmRadioEthernetEntry 8 }
genEquipPmRadioEthernetExceedCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Exceed capacity PM"
::= { genEquipPmRadioEthernetEntry 9 }
genEquipPmRadioEthernetPeakUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Peak utilization PM (%)"
::= { genEquipPmRadioEthernetEntry 10 }
genEquipPmRadioEthernetAverageUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Average utilization PM (%)"
::= { genEquipPmRadioEthernetEntry 11 }
genEquipPmRadioEthernetExceedUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Exceed utilization PM"
::= { genEquipPmRadioEthernetEntry 12 }
genEquipPmRadioEthernetIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioEthernetEntry 13 }
-- Radio Thresholds
genEquipPmRadioEthernetThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioEthernetThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet PMs on the radio link"
::= { genEquipPmRadioEthernet 2 }
genEquipPmRadioEthernetThresholdEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioEthernetThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet PMs on the radio link"
INDEX { genEquipRadioCfgRadioId }
::= { genEquipPmRadioEthernetThresholdTable 1 }
GenEquipPmRadioEthernetThresholdEntry ::=
SEQUENCE {
genEquipPmRadioEthernetThresholdThroughput INTEGER,
genEquipPmRadioEthernetThresholdCapacity INTEGER,
genEquipPmRadioEthernetThresholdUtilization INTEGER
}
genEquipPmRadioEthernetThresholdThroughput OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet Throughput threshold (in Mbps)"
::= { genEquipPmRadioEthernetThresholdEntry 1 }
genEquipPmRadioEthernetThresholdCapacity OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet capacity threshold (in Mbps)"
::= { genEquipPmRadioEthernetThresholdEntry 2 }
genEquipPmRadioEthernetThresholdUtilization OBJECT-TYPE
SYNTAX INTEGER {
above-0(0),
above-20(1),
above-40(2),
above-60(3),
above-80(4),
no-threshold(5)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet utilization threshold (in percentage)."
::= { genEquipPmRadioEthernetThresholdEntry 3 }
-- The Ethernet ETM PMs on the radio link
genEquipPmRadioEthernetEtmTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioEthernetEtmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet PMs on the radio link"
::= { genEquipPmRadioEthernet 3 }
genEquipPmRadioEthernetEtmEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioEthernetEtmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entry of Ethernet ETM PMs on the radio link"
INDEX { genEquipPmRadioEthernetEtmPmType, genEquipPmRadioEthernetEtmPmQueueIndex, genEquipPmRadioEthernetEtmInterval }
::= { genEquipPmRadioEthernetEtmTable 1 }
GenEquipPmRadioEthernetEtmEntry ::=
SEQUENCE {
genEquipPmRadioEthernetEtmPmType
PmTableType,
genEquipPmRadioEthernetEtmPmQueueIndex
INTEGER,
genEquipPmRadioEthernetEtmInterval
INTEGER,
genEquipPmRadioEthernetEtmPmMaxGreenBytesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmAvgGreenBytesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmMaxGreenFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmAvgGreenFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmMaxYellowBytesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmAvgYellowBytesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmMaxYellowFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmAvgYellowFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmMaxRedFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmAvgRedFramesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmIDF
Integrity,
--genEquipPmRadioEthernetEtmPmMaxGreenBytesDropped
-- INTEGER,
--genEquipPmRadioEthernetEtmPmAvgGreenBytesDropped
-- INTEGER,
genEquipPmRadioEthernetEtmPmMaxGreenFramesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmAvgGreenFramesPassed
INTEGER,
--genEquipPmRadioEthernetEtmPmMaxYellowBytesDropped
-- INTEGER,
--genEquipPmRadioEthernetEtmPmAvgYellowBytesDropped
-- INTEGER,
genEquipPmRadioEthernetEtmPmMaxYellowFramesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmAvgYellowFramesPassed
INTEGER,
genEquipPmRadioEthernetEtmPmMaxRedBytesDropped
INTEGER,
genEquipPmRadioEthernetEtmPmAvgRedBytesDropped
INTEGER
}
genEquipPmRadioEthernetEtmPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmRadioEthernetEtmEntry 1 }
genEquipPmRadioEthernetEtmPmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Queue index"
::= { genEquipPmRadioEthernetEtmEntry 2 }
genEquipPmRadioEthernetEtmInterval OBJECT-TYPE
SYNTAX INTEGER (0..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmRadioEthernetEtmEntry 3 }
genEquipPmRadioEthernetEtmPmMaxGreenBytesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Green Traffic Passed Bytes."
::= { genEquipPmRadioEthernetEtmEntry 4 }
genEquipPmRadioEthernetEtmPmAvgGreenBytesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Green Traffic Passed Bytes."
::= { genEquipPmRadioEthernetEtmEntry 5 }
genEquipPmRadioEthernetEtmPmMaxGreenFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Green Traffic Frames Droped by WRED."
::= { genEquipPmRadioEthernetEtmEntry 6 }
genEquipPmRadioEthernetEtmPmAvgGreenFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Green Traffic Frames Droped by WRED."
::= { genEquipPmRadioEthernetEtmEntry 7 }
genEquipPmRadioEthernetEtmPmMaxYellowBytesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Yellow Traffic Passed Bytes."
::= { genEquipPmRadioEthernetEtmEntry 8 }
genEquipPmRadioEthernetEtmPmAvgYellowBytesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Yellow Traffic Passed Bytes."
::= { genEquipPmRadioEthernetEtmEntry 9 }
genEquipPmRadioEthernetEtmPmMaxYellowFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Yellow Traffic Frames Droped by WRED."
::= { genEquipPmRadioEthernetEtmEntry 10 }
genEquipPmRadioEthernetEtmPmAvgYellowFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Yellow Traffic Frames Droped by WRED."
::= { genEquipPmRadioEthernetEtmEntry 11 }
genEquipPmRadioEthernetEtmPmMaxRedFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Red Traffic Frames Dropped."
::= { genEquipPmRadioEthernetEtmEntry 12 }
genEquipPmRadioEthernetEtmPmAvgRedFramesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Red Traffic Frames Dropped."
::= { genEquipPmRadioEthernetEtmEntry 13 }
genEquipPmRadioEthernetEtmPmIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioEthernetEtmEntry 14 }
--genEquipPmRadioEthernetEtmPmMaxGreenBytesDropped OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Maximum Green Traffic Dropped Bytes."
-- ::= { genEquipPmRadioEthernetEtmEntry 15}
--genEquipPmRadioEthernetEtmPmAvgGreenBytesDropped OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Average Green Traffic Dropped Bytes."
-- ::= { genEquipPmRadioEthernetEtmEntry 16}
genEquipPmRadioEthernetEtmPmMaxGreenFramesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Green Traffic Frames Passed."
::= { genEquipPmRadioEthernetEtmEntry 17}
genEquipPmRadioEthernetEtmPmAvgGreenFramesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Green Traffic Frames Passed."
::= { genEquipPmRadioEthernetEtmEntry 18}
--genEquipPmRadioEthernetEtmPmMaxYellowBytesDropped OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Maximum Yellow Traffic Dropped Bytes."
-- ::= { genEquipPmRadioEthernetEtmEntry 19}
--genEquipPmRadioEthernetEtmPmAvgYellowBytesDropped OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Average Yellow Traffic Dropped Bytes."
-- ::= { genEquipPmRadioEthernetEtmEntry 20}
genEquipPmRadioEthernetEtmPmMaxYellowFramesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Yellow Traffic Frames Passed."
::= { genEquipPmRadioEthernetEtmEntry 21}
genEquipPmRadioEthernetEtmPmAvgYellowFramesPassed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Yellow Traffic Frames Passed."
::= { genEquipPmRadioEthernetEtmEntry 22}
genEquipPmRadioEthernetEtmPmMaxRedBytesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Red Traffic Bytes Dropped."
::= { genEquipPmRadioEthernetEtmEntry 23}
genEquipPmRadioEthernetEtmPmAvgRedBytesDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Red Traffic Bytes Dropped."
::= { genEquipPmRadioEthernetEtmEntry 24}
--
genEquipPmRadioMSETable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioMSEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio MSE PM"
::= { genEquipPmRadio 4 }
genEquipPmRadioMSEEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioMSEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio MSE PM"
INDEX { genEquipPmRadioMSEPmType, ifIndex, genEquipPmRadioMSEInterval }
::= { genEquipPmRadioMSETable 1 }
GenEquipPmRadioMSEEntry ::=
SEQUENCE {
genEquipPmRadioMSEPmType PmTableType,
genEquipPmRadioMSEInterval INTEGER,
genEquipPmRadioMSEMinMse INTEGER,
genEquipPmRadioMSEMaxMse INTEGER,
genEquipPmRadioMSEexceeded INTEGER,
genEquipPmRadioMSEIDF Integrity
}
genEquipPmRadioMSEPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmRadioMSEEntry 1 }
genEquipPmRadioMSEInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmRadioMSEEntry 2 }
genEquipPmRadioMSEMinMse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the minimum MSE value detected in the interval."
::= { genEquipPmRadioMSEEntry 3 }
genEquipPmRadioMSEMaxMse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the maximum MSE value detected in the interval."
::= { genEquipPmRadioMSEEntry 4 }
genEquipPmRadioMSEexceeded OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the number of seconds that the MSE exceeded the configured threshold."
::= { genEquipPmRadioMSEEntry 5 }
genEquipPmRadioMSEIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioMSEEntry 6 }
-- Radio Thresold
genEquipPmRadioThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio MSE PM"
::= { genEquipPmRadio 5 }
genEquipPmRadioThresholdEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio MSE PM"
INDEX { genEquipRadioCfgRadioId }
::= { genEquipPmRadioThresholdTable 1 }
GenEquipPmRadioThresholdEntry ::=
SEQUENCE {
genEquipPmRadioThresholdMSE INTEGER,
genEquipPmRadioThresholdRSL1 INTEGER,
genEquipPmRadioThresholdRSL2 INTEGER,
genEquipPmRadioThresholdTSL INTEGER,
genEquipPmRadioThresholdXPI INTEGER
}
genEquipPmRadioThresholdMSE OBJECT-TYPE
SYNTAX INTEGER (-99..-1)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold above which MSE (Mean Square Error) exceeded seconds will be counted"
::= { genEquipPmRadioThresholdEntry 1 }
genEquipPmRadioThresholdRSL1 OBJECT-TYPE
SYNTAX INTEGER (-75..-15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold below which RSL 1 exceeded seconds will be counted"
::= { genEquipPmRadioThresholdEntry 2 }
genEquipPmRadioThresholdRSL2 OBJECT-TYPE
SYNTAX INTEGER (-75..-15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold below which RSL 2 exceeded seconds will be counted"
::= { genEquipPmRadioThresholdEntry 3 }
genEquipPmRadioThresholdTSL OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold above which TSL exceeded seconds will be counted"
::= { genEquipPmRadioThresholdEntry 4 }
genEquipPmRadioThresholdXPI OBJECT-TYPE
SYNTAX INTEGER (0..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold above which XPI (Cross Polar Interference) exceeded seconds will be counted"
::= { genEquipPmRadioThresholdEntry 5 }
-- Radio XPIC
genEquipPmRadioXPITable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmRadioXPIEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio XPIC PM"
::= { genEquipPmRadio 6 }
genEquipPmRadioXPIEntry OBJECT-TYPE
SYNTAX GenEquipPmRadioXPIEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radio XPIC PM"
INDEX { genEquipPmRadioXPIPmType, ifIndex, genEquipPmRadioXPIPmInterval }
::= { genEquipPmRadioXPITable 1 }
GenEquipPmRadioXPIEntry ::=
SEQUENCE {
genEquipPmRadioXPIPmType PmTableType,
genEquipPmRadioXPIPmInterval INTEGER,
genEquipPmRadioXPIPmMinXPI INTEGER,
genEquipPmRadioXPIPmMaxXPI INTEGER,
genEquipPmRadioXPIBelowThreshold INTEGER,
genEquipPmRadioXPIIDF Integrity
}
genEquipPmRadioXPIPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmRadioXPIEntry 1 }
genEquipPmRadioXPIPmInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the interval: 1-30 in case the interval is 24 hours or 1-900 in case the interval is 15 minutes"
::= { genEquipPmRadioXPIEntry 2 }
genEquipPmRadioXPIPmMinXPI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the minimum XPI value detected in the interval"
::= { genEquipPmRadioXPIEntry 3 }
genEquipPmRadioXPIPmMaxXPI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the maximum XPI value detected in the interval"
::= { genEquipPmRadioXPIEntry 4 }
genEquipPmRadioXPIBelowThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter holds the number of seconds in the interval that the XPI value was below the configured threshold."
::= { genEquipPmRadioXPIEntry 5 }
genEquipPmRadioXPIIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmRadioXPIEntry 6 }
-- Clear RAdio PM
genEquipPmRadioClear OBJECT-TYPE
SYNTAX OffOn
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear all radio PMs (Performance Monitoring)."
::= { genEquipPmRadio 7 }
-- TDM (E1/T1) PM Group
genEquipPmTDM OBJECT IDENTIFIER ::= {genEquipPmAll 5}
-- TDM (E1/T1) PM Table
genEquipPmTdmTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The line TDM PM table"
::= { genEquipPmTDM 1 }
genEquipPmTdmEntry OBJECT-TYPE
SYNTAX GenEquipPmTdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The line TDM PM table"
INDEX { genEquipPmTdmPmType, ifIndex, genEquipPmTdmInterval }
::= { genEquipPmTdmTable 1 }
GenEquipPmTdmEntry ::=
SEQUENCE {
genEquipPmTdmPmType PmTableType,
genEquipPmTdmInterval INTEGER,
genEquipPmTdmES INTEGER,
genEquipPmTdmSES INTEGER,
genEquipPmTdmUAS INTEGER,
genEquipPmTdmBBE INTEGER,
genEquipPmTdmIDF Integrity
}
genEquipPmTdmPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmTdmEntry 1 }
genEquipPmTdmInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmTdmEntry 2 }
genEquipPmTdmES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES PM (Errored second)"
::= { genEquipPmTdmEntry 3 }
genEquipPmTdmSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SES PM (Severe Errored Seconds)"
::= { genEquipPmTdmEntry 4 }
genEquipPmTdmUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UAS PM (Unavailable Seconds)."
::= { genEquipPmTdmEntry 5 }
genEquipPmTdmBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BBE PM (Background Block Errors)"
::= { genEquipPmTdmEntry 6 }
genEquipPmTdmIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmTdmEntry 7 }
-- SDH/Sonet PM Group
genEquipPmSDH OBJECT IDENTIFIER ::= {genEquipPmAll 6}
genEquipPmSdhTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmSdhEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The line SDH PM table."
::= { genEquipPmSDH 1 }
genEquipPmSdhEntry OBJECT-TYPE
SYNTAX GenEquipPmSdhEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The line SDH PM table."
INDEX { genEquipPmSdhPmType, ifIndex, genEquipPmSdhInterval }
::= { genEquipPmSdhTable 1 }
GenEquipPmSdhEntry ::=
SEQUENCE {
genEquipPmSdhPmType PmTableType,
genEquipPmSdhInterval INTEGER,
genEquipPmSdhES INTEGER,
genEquipPmSdhSES INTEGER,
genEquipPmSdhEB INTEGER,
genEquipPmSdhBBE INTEGER,
genEquipPmSdhIDF Integrity,
genEquipPmSdhIfIndex INTEGER,
genEquipPmSdhTimeStamp INTEGER,
genEquipPmSdhUAS INTEGER
}
genEquipPmSdhPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmSdhEntry 1 }
genEquipPmSdhInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmSdhEntry 2 }
genEquipPmSdhES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES STM-1/OC-3 PM."
::= { genEquipPmSdhEntry 3 }
genEquipPmSdhSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SES STM-1/OC-3 PM."
::= { genEquipPmSdhEntry 4 }
genEquipPmSdhEB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"EB STM-1/OC-3 PM (Errored block)."
::= { genEquipPmSdhEntry 5 }
genEquipPmSdhBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BBE PM (background errored block STM-1/OC-3 PM or CVL PM (code violation line) when using OC-3."
::= { genEquipPmSdhEntry 6 }
genEquipPmSdhIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmSdhEntry 7 }
genEquipPmSdhIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Number."
::= { genEquipPmSdhEntry 8 }
genEquipPmSdhTimeStamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time stamp of the interval."
::= { genEquipPmSdhEntry 9 }
genEquipPmSdhUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Un-Available Seconds STM-1/OC-3 PM."
::= { genEquipPmSdhEntry 10 }
-- SONET/STM-1 interface-level PMs for line to radio direction - rst-stm1oc3-pm-status-ltor-table
--
genEquipPmSdhRstLRTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmSdhRstLREntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SONET/STM-1 interface-level PMs for line to radio direction."
::= { genEquipPmSDH 2 }
genEquipPmSdhRstLREntry OBJECT-TYPE
SYNTAX GenEquipPmSdhRstLREntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SONET/STM-1 interface-level PMs for line to radio direction entry."
INDEX { genEquipPmSdhRstLRPmType,
genEquipPmSdhRstLRIfIndex,
genEquipPmSdhRstLRInterval }
::= { genEquipPmSdhRstLRTable 1 }
GenEquipPmSdhRstLREntry ::=
SEQUENCE {
genEquipPmSdhRstLRPmType PmTableType,
genEquipPmSdhRstLRIfIndex INTEGER,
genEquipPmSdhRstLRInterval INTEGER,
genEquipPmSdhRstLRTimeStamp INTEGER,
genEquipPmSdhRstLRES INTEGER,
genEquipPmSdhRstLRSES INTEGER,
genEquipPmSdhRstLRUAS INTEGER,
genEquipPmSdhRstLREB INTEGER,
genEquipPmSdhRstLRCV INTEGER,
genEquipPmSdhRstLRBBE INTEGER,
genEquipPmSdhRstLRIDF Integrity
}
genEquipPmSdhRstLRPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmSdhRstLREntry 1 }
genEquipPmSdhRstLRIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number."
::= { genEquipPmSdhRstLREntry 2 }
genEquipPmSdhRstLRInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmSdhRstLREntry 3 }
genEquipPmSdhRstLRTimeStamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time stamp of the interval."
::= { genEquipPmSdhRstLREntry 4 }
genEquipPmSdhRstLRES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds PM for STM-1/OC-3 on line to radio direction."
::= { genEquipPmSdhRstLREntry 5 }
genEquipPmSdhRstLRSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Severely Errored Seconds PM for STM-1/OC-3 on line to radio direction."
::= { genEquipPmSdhRstLREntry 6 }
genEquipPmSdhRstLRUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable Seconds PM for STM-1/OC-3."
::= { genEquipPmSdhRstLREntry 7 }
genEquipPmSdhRstLREB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Blocks PM for STM-1/OC-3 on line to radio direction."
::= { genEquipPmSdhRstLREntry 8 }
genEquipPmSdhRstLRCV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Code Viloations PM for STM-1/OC-3 on line to radio direction."
::= { genEquipPmSdhRstLREntry 9 }
genEquipPmSdhRstLRBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Background Block Error PM for STM-1/OC-3 on line to radio direction."
::= { genEquipPmSdhRstLREntry 10 }
genEquipPmSdhRstLRIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmSdhRstLREntry 11 }
-- SONET/STM-1 interface-level PMs for radio to line direction - rst-stm1oc3-pm-status-crl-type
--
genEquipPmSdhRstRLTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmSdhRstRLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SONET/STM-1 interface-level PMs for radio to line direction."
::= { genEquipPmSDH 3 }
genEquipPmSdhRstRLEntry OBJECT-TYPE
SYNTAX GenEquipPmSdhRstRLEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SONET/STM-1 interface-level PMs for radio to line direction entry."
INDEX { genEquipPmSdhRstRLPmType,
genEquipPmSdhRstRLIfIndex,
genEquipPmSdhRstRLInterval }
::= { genEquipPmSdhRstRLTable 1 }
GenEquipPmSdhRstRLEntry ::=
SEQUENCE {
genEquipPmSdhRstRLPmType PmTableType,
genEquipPmSdhRstRLIfIndex INTEGER,
genEquipPmSdhRstRLInterval INTEGER,
genEquipPmSdhRstRLTimeStamp INTEGER,
genEquipPmSdhRstRLES INTEGER,
genEquipPmSdhRstRLSES INTEGER,
genEquipPmSdhRstRLUAS INTEGER,
genEquipPmSdhRstRLEB INTEGER,
genEquipPmSdhRstRLCV INTEGER,
genEquipPmSdhRstRLBBE INTEGER,
genEquipPmSdhRstRLIDF Integrity
}
genEquipPmSdhRstRLPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmSdhRstRLEntry 1 }
genEquipPmSdhRstRLIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number."
::= { genEquipPmSdhRstRLEntry 2 }
genEquipPmSdhRstRLInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmSdhRstRLEntry 3 }
genEquipPmSdhRstRLTimeStamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the time stamp of the interval."
::= { genEquipPmSdhRstRLEntry 4 }
genEquipPmSdhRstRLES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Seconds PM for STM-1/OC-3 on radio to line direction."
::= { genEquipPmSdhRstRLEntry 5 }
genEquipPmSdhRstRLSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Severely Errored Seconds PM for STM-1/OC-3 on radio to line direction."
::= { genEquipPmSdhRstRLEntry 6 }
genEquipPmSdhRstRLUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable Seconds PM for STM-1/OC-3."
::= { genEquipPmSdhRstRLEntry 7 }
genEquipPmSdhRstRLEB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored Blocks PM for STM-1/OC-3 on radio to line direction."
::= { genEquipPmSdhRstRLEntry 8 }
genEquipPmSdhRstRLCV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Code Viloations PM for STM-1/OC-3 on radio to line direction."
::= { genEquipPmSdhRstRLEntry 9 }
genEquipPmSdhRstRLBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Background Block Error PM for STM-1/OC-3 on radio to line direction."
::= { genEquipPmSdhRstRLEntry 10 }
genEquipPmSdhRstRLIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmSdhRstRLEntry 11 }
-- Trails PM Group
genEquipPmTrails OBJECT IDENTIFIER ::= {genEquipPmAll 7}
-- TDM (E1/T1) PM Table
genEquipPmTrailsEndPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmTrailsEndPointEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PM table of the E1/T1 trails."
::= { genEquipPmTrails 1 }
genEquipPmTrailsEndPointEntry OBJECT-TYPE
SYNTAX GenEquipPmTrailsEndPointEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PM table of the E1/T1 trails."
INDEX { genEquipPmTrailsEndPointPmType, genEquipPmTrailsEndPointId, genEquipPmTrailsEndPointEPId, genEquipPmTrailsEndPointInterval }
::= { genEquipPmTrailsEndPointTable 1 }
GenEquipPmTrailsEndPointEntry ::=
SEQUENCE {
genEquipPmTrailsEndPointPmType PmTableType,
genEquipPmTrailsEndPointId DisplayString,
genEquipPmTrailsEndPointEPId INTEGER,
genEquipPmTrailsEndPointInterval INTEGER,
genEquipPmTrailsEndPointES INTEGER,
genEquipPmTrailsEndPointSES INTEGER,
genEquipPmTrailsEndPointUAS INTEGER,
genEquipPmTrailsEndPointBBE INTEGER,
genEquipPmTrailsEndPointNoOfSwitches INTEGER,
genEquipPmTrailsEndPointActivePathCounts INTEGER,
genEquipPmTrailsEndPointIDF Integrity
}
genEquipPmTrailsEndPointPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmTrailsEndPointEntry 1 }
genEquipPmTrailsEndPointId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the trail id."
::= { genEquipPmTrailsEndPointEntry 2 }
genEquipPmTrailsEndPointEPId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the end point number for this trail.
If the trail is protected, there will be two end points for the trail (primary path and the secondary path)."
::= { genEquipPmTrailsEndPointEntry 3 }
genEquipPmTrailsEndPointInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmTrailsEndPointEntry 4 }
genEquipPmTrailsEndPointES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES PM (Errored Seconds)."
::= { genEquipPmTrailsEndPointEntry 5 }
genEquipPmTrailsEndPointSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SES PM (Severe Errored Seconds)."
::= { genEquipPmTrailsEndPointEntry 6 }
genEquipPmTrailsEndPointUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UAS PM (Unavailable Seconds)."
::= { genEquipPmTrailsEndPointEntry 7 }
genEquipPmTrailsEndPointBBE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BBE PM (Background Block Errors)."
::= { genEquipPmTrailsEndPointEntry 8 }
genEquipPmTrailsEndPointNoOfSwitches OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A counter of the number of SNCP switches (between primary and secondary paths) that trail had in the relevant interval."
::= { genEquipPmTrailsEndPointEntry 9 }
genEquipPmTrailsEndPointActivePathCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active path seconds. "
::= { genEquipPmTrailsEndPointEntry 10 }
genEquipPmTrailsEndPointIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmTrailsEndPointEntry 11 }
-- PW PM Group
genEquipPmPW OBJECT IDENTIFIER ::= {genEquipPmAll 8}
-- TDM (E1/T1) PM Table
genEquipPmPWTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmPWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table shows standard pseudowire-level PM measurements. Notice that PMs at the TDM port level are maintained separately."
::= { genEquipPmPW 1 }
genEquipPmPWEntry OBJECT-TYPE
SYNTAX GenEquipPmPWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table shows standard pseudowire-level PM measurements. Notice that PMs at the TDM port level are maintained separately."
INDEX { genEquipPmPWPmType, genEquipPmPWId, genEquipPmPWInterval }
::= { genEquipPmPWTable 1 }
GenEquipPmPWEntry ::=
SEQUENCE {
genEquipPmPWPmType
PmTableType,
genEquipPmPWId
INTEGER,
genEquipPmPWInterval
INTEGER,
genEquipPmPWMissingPkts
INTEGER,
genEquipPmPWPktsReOrder
INTEGER,
genEquipPmPWtrBfrUnderruns
INTEGER,
genEquipPmPWMisOrderDropped
INTEGER,
genEquipPmPWMalformedPkt
INTEGER,
genEquipPmPWES
INTEGER,
genEquipPmPWSES
INTEGER,
genEquipPmPWUAS
INTEGER,
genEquipPmPWFC
INTEGER,
genEquipPmPWIDF
Integrity
}
genEquipPmPWPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmPWEntry 1 }
genEquipPmPWId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the trail id."
::= { genEquipPmPWEntry 2 }
genEquipPmPWInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmPWEntry 3 }
genEquipPmPWMissingPkts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of missing packets (as detected via control word sequence number gaps)."
::= { genEquipPmPWEntry 4 }
genEquipPmPWPktsReOrder OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected out of sequence (via control word sequence number) but successfully re-ordered."
::= { genEquipPmPWEntry 5 }
genEquipPmPWtrBfrUnderruns OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times a packet needed to be played out and the jitter buffer was empty."
::= { genEquipPmPWEntry 6 }
genEquipPmPWMisOrderDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected out of order (via control word sequence numbers) that could not be re-ordered or could
not fit in the jitter buffer."
::= { genEquipPmPWEntry 7 }
genEquipPmPWMalformedPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected with unexpected size, or bad headers' stack."
::= { genEquipPmPWEntry 8 }
genEquipPmPWES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES PM (Errored Seconds)."
::= { genEquipPmPWEntry 9 }
genEquipPmPWSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SES PM (Severe Errored Seconds)."
::= { genEquipPmPWEntry 10 }
genEquipPmPWUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UAS PM (Unavailable Seconds)."
::= { genEquipPmPWEntry 11 }
genEquipPmPWFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FC (Failure Counts) PM. A failure is a LOPS event."
::= { genEquipPmPWEntry 12 }
genEquipPmPWIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmPWEntry 13 }
--
-- PW service PMs table - pw-service-pm-status-table
--
genEquipPmNGPWTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmNGPWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains PW Performance Monitoring counters."
::= { genEquipPmPW 2 }
genEquipPmNGPWEntry OBJECT-TYPE
SYNTAX GenEquipPmNGPWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table entry contains PW Performance Monitoring counters."
INDEX { genEquipPmNGPWPmType, genEquipPmNGPWIfIndex, genEquipPmNGPWInterval }
::= { genEquipPmNGPWTable 1 }
GenEquipPmNGPWEntry ::=
SEQUENCE {
genEquipPmNGPWPmType
PmTableType,
genEquipPmNGPWIfIndex
INTEGER,
genEquipPmNGPWInterval
INTEGER,
genEquipPmNGPWES
INTEGER,
genEquipPmNGPWSES
INTEGER,
genEquipPmNGPWUAS
INTEGER,
genEquipPmNGPWFC
INTEGER,
genEquipPmNGPWFER
INTEGER,
genEquipPmNGPWMissingPkts
INTEGER,
genEquipPmNGPWPktsReOrder
INTEGER,
genEquipPmNGPWMisOrderDropped
INTEGER,
genEquipPmNGPWMalformedPkt
INTEGER,
genEquipPmNGPWIdf
Integrity
}
genEquipPmNGPWPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
::= { genEquipPmNGPWEntry 1 }
genEquipPmNGPWIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the interface Index."
::= { genEquipPmNGPWEntry 2 }
genEquipPmNGPWInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM."
::= { genEquipPmNGPWEntry 3 }
genEquipPmNGPWES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES (Errored Seconds) PM."
::= { genEquipPmNGPWEntry 4 }
genEquipPmNGPWSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SES (Severe Errored Seconds) PM."
::= { genEquipPmNGPWEntry 5 }
genEquipPmNGPWUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UAS (Unavailable Seconds) PM."
::= { genEquipPmNGPWEntry 6 }
genEquipPmNGPWFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FC (Failure Counts) PM. A failure is a LOPS event."
::= { genEquipPmNGPWEntry 7 }
genEquipPmNGPWFER OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frame Error Ratio."
::= { genEquipPmNGPWEntry 8 }
genEquipPmNGPWMissingPkts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of missing packets (as detected via control word sequence number gaps)."
::= { genEquipPmNGPWEntry 9 }
genEquipPmNGPWPktsReOrder OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected out of sequence (via control word sequence number) but successfully re-ordered."
::= { genEquipPmNGPWEntry 10 }
genEquipPmNGPWMisOrderDropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected out of order (via control word sequence numbers) that could not be re-ordered or could not fit in the jitter buffer."
::= { genEquipPmNGPWEntry 11 }
genEquipPmNGPWMalformedPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets detected with unexpected size, or bad headers' stack."
::= { genEquipPmNGPWEntry 12 }
genEquipPmNGPWIdf OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmNGPWEntry 13 }
-- PM Utilization
genEquipPmEthUtilization OBJECT IDENTIFIER ::= {genEquipPmAll 9}
genEquipPmEthUtilizationAdmin OBJECT-TYPE
SYNTAX EnableDisable
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet port utilization PM admin"
::= { genEquipPmEthUtilization 1 }
genEquipPmEthUtilizationThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User defined threshold for Ethernet port utilization PM."
::= { genEquipPmEthUtilization 2 }
genEquipPmEthUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthUtilizationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet ports Utilization PMs"
::= { genEquipPmEthUtilization 3 }
genEquipPmEthUtilizationEntry OBJECT-TYPE
SYNTAX GenEquipPmEthUtilizationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet ports Utilization PMs"
INDEX { genEquipPmEthUtilizationPmType, ifIndex, genEquipPmEthUtilizationInterval }
::= { genEquipPmEthUtilizationTable 1 }
GenEquipPmEthUtilizationEntry ::=
SEQUENCE {
genEquipPmEthUtilizationPmType PmTableType,
genEquipPmEthUtilizationInterval INTEGER,
genEquipPmEthUtilizationPeakUtilization INTEGER,
genEquipPmEthUtilizationAverageUtilization INTEGER,
genEquipPmEthUtilizationExceedUtilization INTEGER,
genEquipPmEthUtilizationIDF Integrity
}
genEquipPmEthUtilizationPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmEthUtilizationEntry 1 }
genEquipPmEthUtilizationInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmEthUtilizationEntry 2 }
genEquipPmEthUtilizationPeakUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak Ethernet port utilization of the current interval."
::= { genEquipPmEthUtilizationEntry 3 }
genEquipPmEthUtilizationAverageUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Ethernet port utilization of the current interval."
::= { genEquipPmEthUtilizationEntry 4 }
genEquipPmEthUtilizationExceedUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds in current interval when Ethernet port utilization exceeded the user defined threshold."
::= { genEquipPmEthUtilizationEntry 5 }
genEquipPmEthUtilizationIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmEthUtilizationEntry 6 }
-- PM Utilization
genEquipPmEthernetIngressPolicer OBJECT IDENTIFIER ::= {genEquipPmAll 10}
--
-- Logical Port unicast policer statistics - sw-ap-l2-if-logical-ingress-policer1-unicast-statistics-table
--
genEquipPmEthernetIngressPolicerUnicastStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"logical Interface unicast policer statistics."
::= { genEquipPmEthernetIngressPolicer 1 }
genEquipPmEthernetIngressPolicerUnicastStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"logical Interface unicast policer statistics."
INDEX { genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsTable 1 }
GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerUnicastStatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerUnicastStatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerUnicastStatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerUnicastStatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerUnicastStatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerUnicastStatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerUnicastStatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 1 }
genEquipPmEthernetIngressPolicerUnicastStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 2 }
genEquipPmEthernetIngressPolicerUnicastStatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 3 }
genEquipPmEthernetIngressPolicerUnicastStatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 4 }
genEquipPmEthernetIngressPolicerUnicastStatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 5 }
genEquipPmEthernetIngressPolicerUnicastStatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 6 }
genEquipPmEthernetIngressPolicerUnicastStatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 7 }
genEquipPmEthernetIngressPolicerUnicastStatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 8 }
--
-- Logical Port unicast policer statistics - sw-ap-l2-if-logical-ingress-policer2-multicast-statistics-table
--
genEquipPmEthernetIngressPolicerMulticastStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Logical Port multicast policer statistics."
::= { genEquipPmEthernetIngressPolicer 2 }
genEquipPmEthernetIngressPolicerMulticastStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Logical Port multicast policer statistics."
INDEX { genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsTable 1 }
GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerMulticastStatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerMulticastStatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerMulticastStatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerMulticastStatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerMulticastStatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerMulticastStatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerMulticastStatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 1 }
genEquipPmEthernetIngressPolicerMulticastStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 2 }
genEquipPmEthernetIngressPolicerMulticastStatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 3 }
genEquipPmEthernetIngressPolicerMulticastStatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 4 }
genEquipPmEthernetIngressPolicerMulticastStatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 5 }
genEquipPmEthernetIngressPolicerMulticastStatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 6 }
genEquipPmEthernetIngressPolicerMulticastStatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 7 }
genEquipPmEthernetIngressPolicerMulticastStatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 8 }
--
-- Logical Port broadcast policer statistics - sw-ap-l2-if-logical-ingress-policer3-broadcast-statistics-table
--
genEquipPmEthernetIngressPolicerBroadcastStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port broadcast policer statistics."
::= { genEquipPmEthernetIngressPolicer 3 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port broadcast policer statistics."
INDEX { genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsTable 1 }
GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerBroadcastStatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerBroadcastStatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerBroadcastStatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 1 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 2 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 3 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 4 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 5 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 6 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 7 }
genEquipPmEthernetIngressPolicerBroadcastStatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 8 }
--
-- Logical Port ether Type 1 policer statistics - sw-ap-l2-if-logical-ingress-policer4-eth-type1-statistics-table
--
genEquipPmEthernetIngressPolicerEtherType1StatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 1 policer statistics."
::= { genEquipPmEthernetIngressPolicer 4 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 1 policer statistics."
INDEX { genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsTable 1 }
GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerEtherType1StatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType1StatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType1StatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 1 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 2 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 3 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 4 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 5 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 6 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 7 }
genEquipPmEthernetIngressPolicerEtherType1StatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 8 }
--
-- Logical Port ether Type 2 policer statistics - sw-ap-l2-if-logical-ingress-policer5-eth-type2-statistics-table
--
genEquipPmEthernetIngressPolicerEtherType2StatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 2 policer statistics."
::= { genEquipPmEthernetIngressPolicer 5 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 2 policer statistics."
INDEX { genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsTable 1 }
GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerEtherType2StatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType2StatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType2StatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 1 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 2 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 3 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 4 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 5 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 6 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 7 }
genEquipPmEthernetIngressPolicerEtherType2StatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 8 }
--
-- Logical Port ether Type 3 policer statistics - sw-ap-l2-if-logical-ingress-policer6-eth-type3-statistics-table
--
genEquipPmEthernetIngressPolicerEtherType3StatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 3 policer statistics."
::= { genEquipPmEthernetIngressPolicer 6 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface Logical Port ether Type 3 policer statistics."
INDEX { genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex }
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsTable 1 }
GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex
INTEGER,
genEquipPmEthernetIngressPolicerEtherType3StatisticsClearOnRead
NoYes,
genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowBytes
Counter64,
genEquipPmEthernetIngressPolicerEtherType3StatisticsRedPacket
Counter64,
genEquipPmEthernetIngressPolicerEtherType3StatisticsRedBytes
Counter64
}
genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Logical port if-index table key"
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 1 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear counter statistics after reading."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 2 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 3 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as green."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 4 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 5 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as yellow."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 6 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 7 }
genEquipPmEthernetIngressPolicerEtherType3StatisticsRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were counted as red."
::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 8 }
--
-- Interface physical Port RMON statistics - sw-ap-l2-if-phy-rmon-statistics-table
--
genEquipPmEthernetRmonStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetRmonStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface physical Port RMON statistics."
::= { genEquipPmAll 11 }
genEquipPmEthernetRmonStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetRmonStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface physical Port RMON statistics."
INDEX { genEquipPmEthernetRmonStatisticsIfIndex }
::= { genEquipPmEthernetRmonStatisticsTable 1 }
GenEquipPmEthernetRmonStatisticsEntry ::=
SEQUENCE {
genEquipPmEthernetRmonStatisticsIfIndex
INTEGER,
genEquipPmEthernetRmonStatisticsClearOnRead
NoYes,
genEquipPmEthernetRmonStatisticsTxByteCount
Counter64,
genEquipPmEthernetRmonStatisticsTxFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxMulticastFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxBroadcastFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxControlFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxPauseFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxFcsErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxLengthErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxOversizeFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxUndersizeFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxFragmentFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTxJabberFrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx64FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx65-127FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx128-255FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx256-511FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx512-1023FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx1024-1518FrameCount
Counter,
genEquipPmEthernetRmonStatisticsTx1519-1522FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxByteCount
Counter64,
genEquipPmEthernetRmonStatisticsRxFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxMulticastFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxBroadcastFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxControlFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxPauseFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxFcsErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxLengthErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxcode-ErrorCount
Counter,
genEquipPmEthernetRmonStatisticsRxoversizeFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxundersize-ErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxFragmentFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx64FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx65-127FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx128-255FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx256-511FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx512-1023FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx1024-1518FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRx1519-1522FrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxExceedmaxFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxExceedMaxWithErrorFrameCount
Counter,
genEquipPmEthernetRmonStatisticsRxJabberFrameCount
Counter
}
genEquipPmEthernetRmonStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet Physical port if-index table key"
::= { genEquipPmEthernetRmonStatisticsEntry 1 }
genEquipPmEthernetRmonStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear on read"
::= { genEquipPmEthernetRmonStatisticsEntry 2 }
genEquipPmEthernetRmonStatisticsTxByteCount OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX byte count"
::= { genEquipPmEthernetRmonStatisticsEntry 3 }
genEquipPmEthernetRmonStatisticsTxFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 4 }
genEquipPmEthernetRmonStatisticsTxMulticastFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX multicast frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 5 }
genEquipPmEthernetRmonStatisticsTxBroadcastFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX broadcast frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 6 }
genEquipPmEthernetRmonStatisticsTxControlFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX control frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 7 }
genEquipPmEthernetRmonStatisticsTxPauseFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX pause frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 8 }
genEquipPmEthernetRmonStatisticsTxFcsErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX fcs error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 9 }
genEquipPmEthernetRmonStatisticsTxLengthErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX length error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 10 }
genEquipPmEthernetRmonStatisticsTxOversizeFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX oversize frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 11 }
genEquipPmEthernetRmonStatisticsTxUndersizeFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX undersize frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 12 }
genEquipPmEthernetRmonStatisticsTxFragmentFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX fragment frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 13 }
genEquipPmEthernetRmonStatisticsTxJabberFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX jabber frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 14 }
genEquipPmEthernetRmonStatisticsTx64FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 64 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 15 }
genEquipPmEthernetRmonStatisticsTx65-127FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 65-127 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 16 }
genEquipPmEthernetRmonStatisticsTx128-255FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 128-255 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 17 }
genEquipPmEthernetRmonStatisticsTx256-511FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 256-511 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 18 }
genEquipPmEthernetRmonStatisticsTx512-1023FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 512-1023 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 19 }
genEquipPmEthernetRmonStatisticsTx1024-1518FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 1024-1518 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 20 }
genEquipPmEthernetRmonStatisticsTx1519-1522FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX 1519-1522 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 21 }
genEquipPmEthernetRmonStatisticsRxByteCount OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX byte count"
::= { genEquipPmEthernetRmonStatisticsEntry 22 }
genEquipPmEthernetRmonStatisticsRxFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 23 }
genEquipPmEthernetRmonStatisticsRxMulticastFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX multicast frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 24 }
genEquipPmEthernetRmonStatisticsRxBroadcastFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX broadcast frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 25 }
genEquipPmEthernetRmonStatisticsRxControlFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX control frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 26 }
genEquipPmEthernetRmonStatisticsRxPauseFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX pause frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 27 }
genEquipPmEthernetRmonStatisticsRxFcsErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX fcs error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 28 }
genEquipPmEthernetRmonStatisticsRxLengthErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX length error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 29 }
genEquipPmEthernetRmonStatisticsRxcode-ErrorCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX code error count"
::= { genEquipPmEthernetRmonStatisticsEntry 30 }
genEquipPmEthernetRmonStatisticsRxoversizeFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX oversize frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 31 }
genEquipPmEthernetRmonStatisticsRxundersize-ErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX undersize error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 32 }
genEquipPmEthernetRmonStatisticsRxFragmentFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX fragment frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 33 }
genEquipPmEthernetRmonStatisticsRx64FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 64 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 35 }
genEquipPmEthernetRmonStatisticsRx65-127FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 65-127 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 36 }
genEquipPmEthernetRmonStatisticsRx128-255FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 128-255 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 37 }
genEquipPmEthernetRmonStatisticsRx256-511FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 256-511 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 38 }
genEquipPmEthernetRmonStatisticsRx512-1023FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 512-1023 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 39 }
genEquipPmEthernetRmonStatisticsRx1024-1518FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 1024-1518 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 40 }
genEquipPmEthernetRmonStatisticsRx1519-1522FrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX 1519-1522 frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 41 }
genEquipPmEthernetRmonStatisticsRxExceedmaxFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX exceed max frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 42 }
genEquipPmEthernetRmonStatisticsRxExceedMaxWithErrorFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX exceed max with error frame count"
::= { genEquipPmEthernetRmonStatisticsEntry 43 }
genEquipPmEthernetRmonStatisticsRxJabberFrameCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX jabber frame count - frames with length > 1518 bytes (1522 bytes for VLAN tagged frames) with errors"
::= { genEquipPmEthernetRmonStatisticsEntry 44 }
--
-- Service queues aggragation statistics - sw-ap-l3-srv-egress-queues-aggragate-statistics-table
--
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service queues aggragation statistics."
::= { genEquipPmAll 12 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service queues aggragation statistics."
INDEX { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex}
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTable 1 }
GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry ::=
SEQUENCE {
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex
INTEGER,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex
INTEGER,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsClearOnRead
NoYes,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBitsPerSecond
INTEGER,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBitsPerSecond
INTEGER,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowBytes
Counter64
}
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ifIndex"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 1 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Egress service bundle ID"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 2 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clear on read"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 3 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted green packet"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 4 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted green bytes"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 5 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBitsPerSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted green bits per second"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 6 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped green packet"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 7 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped green bytes"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 8 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted yellow packet"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 9 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted yellow bytes"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 10 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBitsPerSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted yellow bits per second"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 11 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tdropped yellow packet"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 12 }
genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped yellow bytes"
::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 13 }
--
-- Cos Service Point ingress Policer statistics - sw-ap-l4-srv-sp-cos-ingress-policer-statistics-table
--
genEquipServicesCetSpPmCosIngressPolicerStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Cos Service Point ingress Policer statistics."
::= { genEquipPmAll 13 }
genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Cos Service Point ingress Policer statistics."
INDEX { genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex,
genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex,
genEquipServicesCetSpPmCosIngressPolicerStatiCos }
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsTable 1 }
GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry ::=
SEQUENCE {
genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex
INTEGER,
genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex
INTEGER,
genEquipServicesCetSpPmCosIngressPolicerStatiCos
INTEGER,
genEquipServicesCetSpPmCosIngressPolicerStatiClearOnRead
NoYes,
genEquipServicesCetSpPmCosIngressPolicerStatiGreenPacket
Counter64,
genEquipServicesCetSpPmCosIngressPolicerStatiGreenBytes
Counter64,
genEquipServicesCetSpPmCosIngressPolicerStatiYellowPacket
Counter64,
genEquipServicesCetSpPmCosIngressPolicerStatiYellowBytes
Counter64,
genEquipServicesCetSpPmCosIngressPolicerStatiRedPacket
Counter64,
genEquipServicesCetSpPmCosIngressPolicerStatiRedBytes
Counter64
}
genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"service-index"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 1 }
genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"sp-index"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 2 }
genEquipServicesCetSpPmCosIngressPolicerStatiCos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"cos index"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 3 }
genEquipServicesCetSpPmCosIngressPolicerStatiClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear on read"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 4 }
genEquipServicesCetSpPmCosIngressPolicerStatiGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"green-packet"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 5 }
genEquipServicesCetSpPmCosIngressPolicerStatiGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"green-bytes"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 6 }
genEquipServicesCetSpPmCosIngressPolicerStatiYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"yellow-packet"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 7 }
genEquipServicesCetSpPmCosIngressPolicerStatiYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"yellow-bytes"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 8 }
genEquipServicesCetSpPmCosIngressPolicerStatiRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"red-packet"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 9 }
genEquipServicesCetSpPmCosIngressPolicerStatiRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"red-bytes"
::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 10 }
--
-- Service Point ingress Policer statistics - sw-ap-l4-srv-sp-ingress-policer-statistics-table
--
genEquipServicesCetSpPmIngressPolicerStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipServicesCetSpPmIngressPolicerStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service Point ingress Policer statistics."
::= { genEquipPmAll 14 }
genEquipServicesCetSpPmIngressPolicerStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipServicesCetSpPmIngressPolicerStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service Point ingress Policer statistics."
INDEX { genEquipServicesCetSpPmIngressPolicerStatiServiceIndex,
genEquipServicesCetSpPmIngressPolicerStatiSpIndex }
::= { genEquipServicesCetSpPmIngressPolicerStatisticsTable 1 }
GenEquipServicesCetSpPmIngressPolicerStatisticsEntry ::=
SEQUENCE {
genEquipServicesCetSpPmIngressPolicerStatiServiceIndex
INTEGER,
genEquipServicesCetSpPmIngressPolicerStatiSpIndex
INTEGER,
genEquipServicesCetSpPmIngressPolicerStatiClearOnRead
NoYes,
genEquipServicesCetSpPmIngressPolicerStatiGreenPacket
Counter64,
genEquipServicesCetSpPmIngressPolicerStatiGreenBytes
Counter64,
genEquipServicesCetSpPmIngressPolicerStatiYellowPacket
Counter64,
genEquipServicesCetSpPmIngressPolicerStatiYellowBytes
Counter64,
genEquipServicesCetSpPmIngressPolicerStatiRedPacket
Counter64,
genEquipServicesCetSpPmIngressPolicerStatiRedBytes
Counter64
}
genEquipServicesCetSpPmIngressPolicerStatiServiceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"service-index"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 1 }
genEquipServicesCetSpPmIngressPolicerStatiSpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"sp-index"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 2 }
genEquipServicesCetSpPmIngressPolicerStatiClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear on read"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 3 }
genEquipServicesCetSpPmIngressPolicerStatiGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"green-packet"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 4 }
genEquipServicesCetSpPmIngressPolicerStatiGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"green-bytes"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 5 }
genEquipServicesCetSpPmIngressPolicerStatiYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"yellow-packet"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 6 }
genEquipServicesCetSpPmIngressPolicerStatiYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"yellow-bytes"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 7 }
genEquipServicesCetSpPmIngressPolicerStatiRedPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"red-packet"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 8 }
genEquipServicesCetSpPmIngressPolicerStatiRedBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"red-bytes"
::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 9 }
--
-- Service Point egress queue statistics - sw-ap-l4-srv-sp-egress-queue-statistics-table
--
genEquipServicesCETTmPmSpEgressQueueStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service Point egress queue statistics."
::= { genEquipPmAll 15 }
genEquipServicesCETTmPmSpEgressQueueStatisticsEntry OBJECT-TYPE
SYNTAX GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Service Point egress queue statistics."
INDEX { genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex,
genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex,
genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex }
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsTable 1 }
GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry ::=
SEQUENCE {
genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex
INTEGER,
genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex
INTEGER,
genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex
INTEGER,
genEquipServicesCETTmPmSpEgressQueueStatisticsClearOnRead
NoYes,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBitsPerSecond
INTEGER,
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBytes
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBitsPerSecond
INTEGER,
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowPacket
Counter64,
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowBytes
Counter64
}
genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ifindex"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 1 }
genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Servic class ID"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 2 }
genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"cos-queue-index"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 3 }
genEquipServicesCETTmPmSpEgressQueueStatisticsClearOnRead OBJECT-TYPE
SYNTAX NoYes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear on read"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 4 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-green-packet"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 5 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-green-bytes"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 6 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBitsPerSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-green-bits-per-second"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 7 }
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped-green-packet"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 8 }
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped-green-bytes"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 9 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-yellow-packet"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 10 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-yellow-bytes"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 11 }
genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBitsPerSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted-yellow-bits-per-second"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 12 }
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowPacket OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped-yellow-packet"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 13 }
genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowBytes OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dropped-yellow-bytes"
::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 14 }
-- PM Utilization
genEquipPmUtilization OBJECT IDENTIFIER ::= {genEquipPmAll 16}
-- PM CPU Utilization
genEquipPmUtilizationCPU OBJECT IDENTIFIER ::= {genEquipPmUtilization 1}
genEquipPmUtilizationCPUAdmin OBJECT-TYPE
SYNTAX EnableDisable
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CPU utilization PM admin"
::= { genEquipPmUtilizationCPU 1 }
genEquipPmUtilizationCPUThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User defined threshold for CPU utilization PM."
::= { genEquipPmUtilizationCPU 2 }
genEquipPmUtilizationCPUTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmUtilizationCPUEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The CPU Utilization PMs"
::= { genEquipPmUtilizationCPU 3 }
genEquipPmUtilizationCPUEntry OBJECT-TYPE
SYNTAX GenEquipPmUtilizationCPUEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The CPU Utilization PMs"
INDEX { genEquipPmUtilizationCPUPmType, genEquipPmUtilizationCPUInterval }
::= { genEquipPmUtilizationCPUTable 1 }
GenEquipPmUtilizationCPUEntry ::=
SEQUENCE {
genEquipPmUtilizationCPUPmType PmTableType,
genEquipPmUtilizationCPUInterval INTEGER,
genEquipPmUtilizationCPUPeakUtilization INTEGER,
genEquipPmUtilizationCPUAverageUtilization INTEGER,
genEquipPmUtilizationCPUMinimumUtilization INTEGER,
genEquipPmUtilizationCPUExceedUtilization INTEGER,
genEquipPmUtilizationCPUIDF Integrity
}
genEquipPmUtilizationCPUPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmUtilizationCPUEntry 1 }
genEquipPmUtilizationCPUInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmUtilizationCPUEntry 2 }
genEquipPmUtilizationCPUPeakUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak CPU utilization of the current interval."
::= { genEquipPmUtilizationCPUEntry 3 }
genEquipPmUtilizationCPUAverageUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average CPU utilization of the current interval."
::= { genEquipPmUtilizationCPUEntry 4 }
genEquipPmUtilizationCPUMinimumUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimal CPU utilization of the current interval."
::= { genEquipPmUtilizationCPUEntry 5 }
genEquipPmUtilizationCPUExceedUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds in the current interval when CPU utilization exceeded user defined threshold."
::= { genEquipPmUtilizationCPUEntry 6 }
genEquipPmUtilizationCPUIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmUtilizationCPUEntry 7 }
-- PM Memory Utilization
genEquipPmUtilizationMem OBJECT IDENTIFIER ::= {genEquipPmUtilization 2}
genEquipPmUtilizationMemAdmin OBJECT-TYPE
SYNTAX EnableDisable
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Memory utilization PM admin"
::= { genEquipPmUtilizationMem 1 }
genEquipPmUtilizationMemThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Memory threshold for Ethernet port utilization PM."
::= { genEquipPmUtilizationMem 2 }
genEquipPmUtilizationMemTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmUtilizationMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Memory Utilization PMs"
::= { genEquipPmUtilizationMem 3 }
genEquipPmUtilizationMemEntry OBJECT-TYPE
SYNTAX GenEquipPmUtilizationMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Memory Utilization PMs"
INDEX { genEquipPmUtilizationMemPmType, genEquipPmUtilizationMemInterval }
::= { genEquipPmUtilizationMemTable 1 }
GenEquipPmUtilizationMemEntry ::=
SEQUENCE {
genEquipPmUtilizationMemPmType PmTableType,
genEquipPmUtilizationMemInterval INTEGER,
genEquipPmUtilizationMemPeakUtilization INTEGER,
genEquipPmUtilizationMemAverageUtilization INTEGER,
genEquipPmUtilizationMemMinimumUtilization INTEGER,
genEquipPmUtilizationMemExceedUtilization INTEGER,
genEquipPmUtilizationMemIDF Integrity
}
genEquipPmUtilizationMemPmType OBJECT-TYPE
SYNTAX PmTableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmUtilizationMemEntry 1 }
genEquipPmUtilizationMemInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval of the PM"
::= { genEquipPmUtilizationMemEntry 2 }
genEquipPmUtilizationMemPeakUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak Memory utilization of the current interval."
::= { genEquipPmUtilizationMemEntry 3 }
genEquipPmUtilizationMemAverageUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average Memory utilization of the current interval."
::= { genEquipPmUtilizationMemEntry 4 }
genEquipPmUtilizationMemMinimumUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds in current interval when Memory utilization exceeded the user defined threshold."
::= { genEquipPmUtilizationMemEntry 5 }
genEquipPmUtilizationMemExceedUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds in current interval when Memory utilization exceeded the user defined threshold."
::= { genEquipPmUtilizationMemEntry 6 }
genEquipPmUtilizationMemIDF OBJECT-TYPE
SYNTAX Integrity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the IDF (Invalid Data Flag), was set."
::= { genEquipPmUtilizationMemEntry 7 }
-- PM Ethernet Port
genEquipPmEthernet OBJECT IDENTIFIER ::= {genEquipPmAll 17}
--
-- PM on Ethernet port counters - sw-ap-l2-if-phy-pm-table
--
genEquipPmEthernetPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenEquipPmEthernetPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PM on Ethernet port counters."
::= { genEquipPmEthernet 1 }
genEquipPmEthernetPortEntry OBJECT-TYPE
SYNTAX GenEquipPmEthernetPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PM on Ethernet port counters entry."
INDEX { genEquipPmEthernetPortPmType,
ifIndex,
genEquipPmEthernetPortPmInterval}
::= { genEquipPmEthernetPortTable 1 }
GenEquipPmEthernetPortEntry ::=
SEQUENCE {
genEquipPmEthernetPortPmType
INTEGER,
genEquipPmEthernetPortPmInterval
INTEGER,
genEquipPmEthernetPortRxAvgBcastPackets
INTEGER,
genEquipPmEthernetPortRxPeakBcastPackets
INTEGER,
genEquipPmEthernetPortRxBytesLayer1ExcedThSecCnt
INTEGER,
genEquipPmEthernetPortRxAvgBytesLayer1
INTEGER,
genEquipPmEthernetPortRxPeakBytesLayer1
INTEGER,
genEquipPmEthernetPortRxAvgBytesLayer2
INTEGER,
genEquipPmEthernetPortRxPeakBytesLayer2
INTEGER,
genEquipPmEthernetPortRxAvgMcastPackets
INTEGER,
genEquipPmEthernetPortRxPeakMcastPackets
INTEGER,
genEquipPmEthernetPortRxAvgPackets
INTEGER,
genEquipPmEthernetPortRxPeakPackets
INTEGER,
genEquipPmEthernetPortTxAvgBcastPackets
INTEGER,
genEquipPmEthernetPortTxPeakBcastPackets
INTEGER,
genEquipPmEthernetPortTxBytesLayer1ExcedThSecCnt
INTEGER,
genEquipPmEthernetPortTxAvgBytesLayer1
INTEGER,
genEquipPmEthernetPortTxPeakBytesLayer1
INTEGER,
genEquipPmEthernetPortTxAvgBytesLayer2
INTEGER,
genEquipPmEthernetPortTxPeakBytesLayer2
INTEGER,
genEquipPmEthernetPortTxAvgMcastPackets
INTEGER,
genEquipPmEthernetPortTxPeakMcastPackets
INTEGER,
genEquipPmEthernetPortTxAvgPackets
INTEGER,
genEquipPmEthernetPortTxPeakPackets
INTEGER,
genEquipPmEthernetPortPmIDF
INTEGER
}
genEquipPmEthernetPortPmType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the PM Type table to access,
15 min, current 15 min, 24 hours or current 24 hours"
::= { genEquipPmEthernetPortEntry 1 }
genEquipPmEthernetPortPmInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the interval: 1-30 in case the interval is 24 hours
or 1-96 in case the interval is 15 minutes"
::= { genEquipPmEthernetPortEntry 2 }
genEquipPmEthernetPortRxAvgBcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average received broadcast packets"
::= { genEquipPmEthernetPortEntry 3 }
genEquipPmEthernetPortRxPeakBcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak received broadcast packets"
::= { genEquipPmEthernetPortEntry 4 }
genEquipPmEthernetPortRxBytesLayer1ExcedThSecCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counter of seconds in interval when received bytes in Layer1 exceeded threshold"
::= { genEquipPmEthernetPortEntry 5 }
genEquipPmEthernetPortRxAvgBytesLayer1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average received bytes in Layer1"
::= { genEquipPmEthernetPortEntry 6 }
genEquipPmEthernetPortRxPeakBytesLayer1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak received bytes in Layer1"
::= { genEquipPmEthernetPortEntry 7 }
genEquipPmEthernetPortRxAvgBytesLayer2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average received bytes in Layer2"
::= { genEquipPmEthernetPortEntry 8 }
genEquipPmEthernetPortRxPeakBytesLayer2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak received bytes in Layer2"
::= { genEquipPmEthernetPortEntry 9 }
genEquipPmEthernetPortRxAvgMcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average received multicast packets"
::= { genEquipPmEthernetPortEntry 10 }
genEquipPmEthernetPortRxPeakMcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak received multicast packets"
::= { genEquipPmEthernetPortEntry 11 }
genEquipPmEthernetPortRxAvgPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average received packets"
::= { genEquipPmEthernetPortEntry 12 }
genEquipPmEthernetPortRxPeakPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak received packets"
::= { genEquipPmEthernetPortEntry 13 }
genEquipPmEthernetPortTxAvgBcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmitted broadcast packets"
::= { genEquipPmEthernetPortEntry 14 }
genEquipPmEthernetPortTxPeakBcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak transmitted broadcast packets"
::= { genEquipPmEthernetPortEntry 15 }
genEquipPmEthernetPortTxBytesLayer1ExcedThSecCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Counter of seconds in interval when transmitted bytes in Layer1 exceeded threshold"
::= { genEquipPmEthernetPortEntry 16 }
genEquipPmEthernetPortTxAvgBytesLayer1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmitted bytes in Layer1"
::= { genEquipPmEthernetPortEntry 17 }
genEquipPmEthernetPortTxPeakBytesLayer1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak transmitted bytes in Layer1"
::= { genEquipPmEthernetPortEntry 18 }
genEquipPmEthernetPortTxAvgBytesLayer2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmitted bytes in Layer2"
::= { genEquipPmEthernetPortEntry 19 }
genEquipPmEthernetPortTxPeakBytesLayer2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak transmitted bytes in Layer2"
::= { genEquipPmEthernetPortEntry 20 }
genEquipPmEthernetPortTxAvgMcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmitted multicast packets"
::= { genEquipPmEthernetPortEntry 21 }
genEquipPmEthernetPortTxPeakMcastPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak transmitted multicast packets"
::= { genEquipPmEthernetPortEntry 22 }
genEquipPmEthernetPortTxAvgPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmitted packets"
::= { genEquipPmEthernetPortEntry 23 }
genEquipPmEthernetPortTxPeakPackets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Peak transmitted packets"
::= { genEquipPmEthernetPortEntry 24 }
genEquipPmEthernetPortPmIDF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if the performance values of the interval can be trusted"
::= { genEquipPmEthernetPortEntry 25 }
-- PM Scalars
genEquipPMStatistics OBJECT IDENTIFIER ::= {genEquipPM 4}
genEquipRMONResetCounters OBJECT-TYPE
SYNTAX OffOn
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear all Ethernet RMON counters."
::= { genEquipPMStatistics 1 }
genEquipPMStatisticsResetAllL2PortPm OBJECT-TYPE
SYNTAX OffOn
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear all L2 port PMs."
::= { genEquipPMStatistics 2 }