mibs/MIBS/ciena/CIENA-CES-BENCHMARK-MIB

3613 lines
153 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- This file was included in WWP MIB release 04-16-00-0047
--
-- CIENA-CES-BENCHMARK-MIB.my
--
--
CIENA-CES-BENCHMARK-MIB DEFINITIONS ::= BEGIN
IMPORTS
Unsigned32, Integer32, Counter64, OBJECT-TYPE,
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus, TruthValue, DisplayString, MacAddress, TEXTUAL-CONVENTION,
DateAndTime
FROM SNMPv2-TC
InetAddressType, InetAddress ,InetAddressPrefixLength
FROM INET-ADDRESS-MIB
cienaCesNotifications, cienaCesConfig, cienaCesStatistics
FROM CIENA-SMI
cienaGlobalSeverity, cienaGlobalMacAddress
FROM CIENA-GLOBAL-MIB;
cienaCesBenchmarkMIB MODULE-IDENTITY
LAST-UPDATED "201610140000Z"
ORGANIZATION "Ciena, Inc"
CONTACT-INFO
" Mib Meister
115 North Sullivan Road
Spokane Valley, WA 99037
USA
Phone: +1 509 242 9000
Email: support@ciena.com"
DESCRIPTION "The MIB module for managing RFC2544/Y1564 service benchmark testing."
REVISION "201611110000Z"
DESCRIPTION "The maximumLineRate(3) value for cienaCesBenchmarkProfileEntryFrameLossStartBw is not supported."
REVISION "201610140000Z"
DESCRIPTION "Add new entity attribute cienaCesBenchmarkEntityEntryReflectorMacValidation
to support MAC-agnostic reflector."
REVISION "201610070000Z"
DESCRIPTION "Updated the description of cienaCesBenchmarkProfileEntryTpid and made
cienaCesBenchmarkEntityStatsEntryClear obsolete. Entity statistics shall
now be cleared using new attribute cienaCesBenchmarkEntityEntryClearStats"
REVISION "201610040000Z"
DESCRIPTION "Fix VID range to allow up to maximum value of 4094"
REVISION "201609070000Z"
DESCRIPTION "Updated default values for various objects to help with 'createAndGo' operations"
REVISION "201606010000Z"
DESCRIPTION "Added Trap cienaCesBenchmarkTestIterationCompleted."
REVISION "201605130000Z"
DESCRIPTION "Updated cienaCesBenchmarkTestStarted, cienaCesBenchmarkTestStopped,
cienaCesBenchmarkTestCompleted, cienaCesBenchmarkTestFailedThroughputKpi,
cienaCesBenchmarkTestFailedFramelossKpi, cienaCesBenchmarkTestFailedLatencyKpi
and cienaCesBenchmarkTestFailedPdvKpi traps to include cienaGlobalSeverity and
cienaGlobalMacAddress."
REVISION "201604260000Z"
DESCRIPTION "Add new throughput test state, txMaxThroughputForYellowTest, to
CienaCesBenchmarkThroughputTestState's definition. Used on green
session when the associated yellow session is running its throughput
test."
REVISION "201603300000Z"
DESCRIPTION "Add cienaCesBenchmarkEmixCharSetTable"
REVISION "201603140000Z"
DESCRIPTION "Add attribute cienaCesBenchmarkTestInstanceEntryAssocEntityId which
points back to the entity ID associated with the test instance."
REVISION "201603100000Z"
DESCRIPTION "Add a special note to the description of
cienaCesBenchmarkGenTestSessionAllocationEntry
for the case when test traffic is untagged."
REVISION "201603030000Z"
DESCRIPTION "Fix description for cienaCesBenchmarkEntityStatsEntryClear
and cienaCesBenchmarkTestInstanceEntryTotalIntervals attributes"
REVISION "201602240000Z"
DESCRIPTION "Added evcOutOfService to the Entity Mode enum"
REVISION "201602090000Z"
DESCRIPTION "Initial creation. Based on WWP-LEOS-BENCHMARK-MIB update 201412180000Z"
::= { cienaCesConfig 39 }
--
-- Textual convention
--
CienaCesBenchmarkLatencyPdvTestState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Test state for latency and packet delay variation tests."
SYNTAX INTEGER {
idle(1),
sendingTraffic(2),
waitingForTimestampData(3),
waitingForResidualPackets(4),
processingResults(5),
stoppedByIntervalTimer(6),
stoppedByDurationTimer(7),
stoppedByUser(8),
done(9)
}
CienaCesBenchmarkThroughputTestState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Throughput test states"
SYNTAX INTEGER {
idle(1),
running(2),
waitingForResidualPackets(3),
processingResults(4),
stoppedByIntervalTimer(5),
stoppedByDurationTimer(6),
stoppedByUser(7),
done(8),
txMaxThroughputForYellowTest(9)
}
CienaCesBenchmarkFramelossTestState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Frame loss test states"
SYNTAX INTEGER {
idle(1),
runningFirstTest(2),
waitingForResidualFirstPackets(3),
processingFirstResults(4),
runningSecondTest(5),
waitingForResidualSecondPackets(6),
processingSecondResults(7),
stoppedByIntervalTimer(8),
stoppedByDurationTimer(9),
stoppedByUser(10),
done(11)
}
CienaCesBenchmarkRfc2544TestState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "RFC 2544 test suite state."
SYNTAX INTEGER {
idle(1),
running(2),
stoppedByIntervalTimer(3),
stoppedByDurationTimer(4),
stoppedByUser(5),
done(6)
}
CienaCesBenchmarkY1564TestState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Y1564 test suite state."
SYNTAX INTEGER {
idle(1),
running(2),
stoppedByIntervalTimer(3),
stoppedByDurationTimer(4),
stoppedByUser(5),
done(6)
}
CienaCesBenchmarkColorTest ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Defines which traffic color needs to be tested. Green
test traffic is generated with DEI bit set to 0 and
uses the profile bandwidth parameter as the starting
bandwidth; yellow test traffic is generated with DEI bit
set to 1 and uses the profile excess-bandwidth parameter
as the starting bandwidth. When testing for red, the test
stream has its DEI bit set to 1 and the starting bandwidth
is (excess-bandwidth * 1.25)"
SYNTAX INTEGER {
green(1),
yellow(2),
greenYellow(3),
greenYellowRed(4)
}
CienaCesBenchmarkKpiResult ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Provides a pass or fail for the test results compared to
the selected KPI profile's pass crieteria for the test."
SYNTAX INTEGER {
notAvailable(1),
pass(2),
fail(3)
}
CienaCesBenchmarkAdminState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Administrative state of an object."
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
CienaCesBenchmarkThroughputKpiPercent ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-4"
STATUS current
DESCRIPTION "Percent of bandwidth that the maximum throughput result
shouldn't go below for the test to be considered a pass.
The value is given as an integer but represent a 4 decimal
point percent. Ex: 0.2000 is reported as 2000."
SYNTAX Unsigned32
CienaCesBenchmarkFramelossKpiPercent ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-4"
STATUS current
DESCRIPTION "Percent of the frameloss test staring bandwidth, the frame
loss shouldn't exceed for the test to be considered a pass.
The value is given as an integer but represent a 4 decimal
point percent. Ex: 0.2000 is reported as 2000."
SYNTAX Unsigned32
CienaCesBenchmarkThroughputResult ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION "Throughput results in Mbps are sent as unsigned integer
multiplied by 100 to provide a 2 decimal point accuracy.
If result is 123.45 Mbps, it is sent as 12345 and should
be divided by 100 by the SNMP application retrieving the
data."
SYNTAX Unsigned32
CienaCesBenchmarkFramelossResult ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION "Frame loss results in Percent of frame loss start bandwidth
are sent as unsigned integer multitplied by 100 to provide a
2 decimal point accuracy.
If result is 12.34 %, it is sent as 1234 and should
be divided by 100 by the SNMP application retrieving the
data."
SYNTAX Unsigned32
CienaCesBenchmarkPcpBitmap ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION "Bitmap of the VLAN PCP (Priority Code ) value to test
with. When The RFC2544 test is selected in the profile,
only 1 PCP bit can be set. For other tests, a test
session will be run simultaneously for each PCP set
in the bitmap. In the later case, the bandwidth will
be distributed among the set PCPs according to the
selected PCP Bandwidth allocation profile. If no
such profile is configured, the bandwidth will evenly
be distributed among all set PCPs."
SYNTAX BITS {
pcp0(0),
pcp1(1),
pcp2(2),
pcp3(3),
pcp4(4),
pcp5(5),
pcp6(6),
pcp7(7)
}
cienaCesBenchmarkMIBObjects OBJECT IDENTIFIER ::= { cienaCesBenchmarkMIB 1 }
cienaCesBenchmarkModule OBJECT IDENTIFIER ::= { cienaCesBenchmarkMIBObjects 1 }
cienaCesBenchmarkGlobalObjects OBJECT IDENTIFIER ::= { cienaCesBenchmarkModule 1 }
cienaCesBenchmarkNotifications OBJECT IDENTIFIER ::= { cienaCesNotifications 39 }
cienaCesBenchmarkGlobalAdminState OBJECT-TYPE
SYNTAX CienaCesBenchmarkAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative state of the benchmark feature
at the global level."
::= { cienaCesBenchmarkGlobalObjects 1 }
cienaCesBenchmarkGlobalGeneratorDefaultEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default EMIX sequence to be used on a test instance
when no EMIX is specified in the test instance
targeted test profile. This applies to generator
test instances only."
::= { cienaCesBenchmarkGlobalObjects 2 }
cienaCesBenchmarkGlobalGeneratorDefaultKpiProfileId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default KPI profile to be used to analyze the results
of a test instance when no KPI profile is specifed in
the targeted test profile. This applies to generator
test instances only."
::= { cienaCesBenchmarkGlobalObjects 3 }
cienaCesBenchmarkGlobalGeneratorDefaultBwAllocProfileId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default bandwidth allocation profile to be used with
a test instance when no bandwidth allocation profile is
specified in the targeted test profile. This applies to
generator test instances only."
::= { cienaCesBenchmarkGlobalObjects 4 }
cienaCesBenchmarkGlobalPlatformMaxConfigEntities OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of entities that can be created on
this platform."
::= { cienaCesBenchmarkGlobalObjects 5 }
cienaCesBenchmarkGlobalPlatformMaxConfigTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of test instances that can be created on
this platform."
::= { cienaCesBenchmarkGlobalObjects 6 }
cienaCesBenchmarkGlobalPlatformMaxConfigTestProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of test profiles that can be created on
this platform."
::= { cienaCesBenchmarkGlobalObjects 7 }
cienaCesBenchmarkGlobalPlatformMaxConfigKpiProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of KPI profiles that can be created on
this platform."
::= { cienaCesBenchmarkGlobalObjects 8 }
cienaCesBenchmarkGlobalPlatformMaxConfigBwAllocProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of bandwidth distribution profiles
that can be created on this platform."
::= { cienaCesBenchmarkGlobalObjects 9 }
cienaCesBenchmarkGlobalPlatformMaxConfigEmixSequences OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of EMIX sequences that can be created on
this platform, including the system created ones."
::= { cienaCesBenchmarkGlobalObjects 10 }
cienaCesBenchmarkGlobalPlatformMaxSimultaneousRunningTests OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of test instances that can be running
simultaneously on this platform."
::= { cienaCesBenchmarkGlobalObjects 11 }
cienaCesBenchmarkGlobalConfiguredEntities OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entities currently configured."
::= { cienaCesBenchmarkGlobalObjects 12 }
cienaCesBenchmarkGlobalConfiguredTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of test instances currently configured."
::= { cienaCesBenchmarkGlobalObjects 13 }
cienaCesBenchmarkGlobalConfiguredProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of test profiles currently configured."
::= { cienaCesBenchmarkGlobalObjects 14 }
cienaCesBenchmarkGlobalConfiguredEmixSequences OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of EMIX sequences currently configured, including
the system created ones."
::= { cienaCesBenchmarkGlobalObjects 15 }
cienaCesBenchmarkGlobalConfiguredKpiProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of KPI profiles currently configured."
::= { cienaCesBenchmarkGlobalObjects 16 }
cienaCesBenchmarkGlobalConfiguredBwAllocProfiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bandwidth distribution profiles currently
configured."
::= { cienaCesBenchmarkGlobalObjects 17 }
cienaCesBenchmarkGlobalEnabledTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of test instances currently enabled across
the platform."
::= { cienaCesBenchmarkGlobalObjects 18 }
cienaCesBenchmarkGlobalGeneratorRunningTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of generator test instances currently running
across the platform."
::= { cienaCesBenchmarkGlobalObjects 19 }
--
-- the Benchmark Entity Config and Status
--
cienaCesBenchmarkEntityTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of benchmark entity entries."
::= { cienaCesBenchmarkModule 2 }
cienaCesBenchmarkEntityEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK Entity characteristics."
INDEX { cienaCesBenchmarkEntityEntryId }
::= { cienaCesBenchmarkEntityTable 1 }
CienaCesBenchmarkEntityEntry ::= SEQUENCE {
cienaCesBenchmarkEntityEntryId Integer32,
cienaCesBenchmarkEntityEntryName DisplayString,
cienaCesBenchmarkEntityEntryRole INTEGER,
cienaCesBenchmarkEntityEntryPortId Integer32,
cienaCesBenchmarkEntityEntryMode INTEGER,
cienaCesBenchmarkEntityEntryAdminState CienaCesBenchmarkAdminState,
cienaCesBenchmarkEntityEntryLocalMac MacAddress,
cienaCesBenchmarkEntityEntrySlotId Integer32,
cienaCesBenchmarkEntityEntryReflectorVendorType INTEGER,
cienaCesBenchmarkEntityEntryReflectionLevel INTEGER,
cienaCesBenchmarkEntityEntryGeneratorHFrameSize Integer32,
cienaCesBenchmarkEntityEntryMaxConfigTestInstances Integer32,
cienaCesBenchmarkEntityEntryMaxSimultaneousTestInstances Integer32,
cienaCesBenchmarkEntityEntryOperEnabled TruthValue,
cienaCesBenchmarkEntityEntryNumTestInstancesConfigured Integer32,
cienaCesBenchmarkEntityEntryNumTestInstancesEnabled Integer32,
cienaCesBenchmarkEntityEntryGenNumTestInstancesRunning Integer32,
cienaCesBenchmarkEntityEntryBwAvailable Integer32,
cienaCesBenchmarkEntityEntryGenBwUsedByRunningTests Integer32,
cienaCesBenchmarkEntityEntryAvailableHwSessions Integer32,
cienaCesBenchmarkEntityEntryAllocatedHwSessions Integer32,
cienaCesBenchmarkEntityEntryRowStatus RowStatus,
cienaCesBenchmarkEntityEntryClearStats TruthValue,
cienaCesBenchmarkEntityEntryReflectorMacValidation TruthValue
}
cienaCesBenchmarkEntityEntryId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entity unique ID"
::= { cienaCesBenchmarkEntityEntry 1 }
cienaCesBenchmarkEntityEntryName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the benchmark entity as entered when created."
::= { cienaCesBenchmarkEntityEntry 2 }
cienaCesBenchmarkEntityEntryRole OBJECT-TYPE
SYNTAX INTEGER {
none(1),
reflector(2),
generator(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Entity role"
DEFVAL { reflector }
::= { cienaCesBenchmarkEntityEntry 3 }
cienaCesBenchmarkEntityEntryPortId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Entity port under test"
::= { cienaCesBenchmarkEntityEntry 4 }
cienaCesBenchmarkEntityEntryMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
inService(2),
outOfService(3),
vidOutOfService(4),
evcOutOfService(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Entity mode"
DEFVAL { inService }
::= { cienaCesBenchmarkEntityEntry 5 }
cienaCesBenchmarkEntityEntryAdminState OBJECT-TYPE
SYNTAX CienaCesBenchmarkAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Entity admin state."
DEFVAL { disabled }
::= { cienaCesBenchmarkEntityEntry 6 }
cienaCesBenchmarkEntityEntryLocalMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The FPGA internal test port assigned mac address."
::= { cienaCesBenchmarkEntityEntry 7 }
cienaCesBenchmarkEntityEntrySlotId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot Id of the line module associated
with this entity."
::= { cienaCesBenchmarkEntityEntry 8 }
cienaCesBenchmarkEntityEntryReflectorVendorType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ciena(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicator as to what type of equipment is generating the
test traffic on the remote end."
DEFVAL { ciena }
::= { cienaCesBenchmarkEntityEntry 9 }
cienaCesBenchmarkEntityEntryReflectionLevel OBJECT-TYPE
SYNTAX INTEGER {
none(1),
l2only(2),
l2ToL3IPv4only(3),
l2ToL3IPv6only(4),
l2ToL4IPv4only(5),
l2ToL4IPv6only(6),
l2ToL4(7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For reflector entities, this indicates the minimum reflection
level required. If test traffic is going over an ethernet L2
cloud, l2-only is fine. But if the test traffic is going over
an IP network, the reflector needs to be able to swap L2 and
L3 fields. Depending on the type of IP network, the user
needs to configured IPv4 or IPv6. L2 to L4 will swap MAC
addresses, IP addresses and src and destination L4 port.
Depending on the reflection level required, a different device
is used to implement the reflector."
::= { cienaCesBenchmarkEntityEntry 10 }
cienaCesBenchmarkEntityEntryGeneratorHFrameSize OBJECT-TYPE
SYNTAX Integer32 (64..9216)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum frame size that should be generated by the generator
device. This H frame size should to leave enough room for
extra encapsulation bytes that will be pushed onto the
packet by the switch when pushing this test packet out
the network side port.
The generator device will ensure that any frame size list
or EMIX used during the test is adjusted accordingly"
::= { cienaCesBenchmarkEntityEntry 11 }
cienaCesBenchmarkEntityEntryMaxConfigTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of test instances that can
be configured on this entity."
::= { cienaCesBenchmarkEntityEntry 12 }
cienaCesBenchmarkEntityEntryMaxSimultaneousTestInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of test instances that can
be enabled (reflector) or running (generator)
on this entity, given the availability of
hw sessions."
::= { cienaCesBenchmarkEntityEntry 13 }
cienaCesBenchmarkEntityEntryOperEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity operational enable/disable. An entity
is operationally enabled when the feature is
enabled, the entity is enabled and at least one
test instance associated with that entity is
enabled (reflector) or running (generator)"
::= { cienaCesBenchmarkEntityEntry 14 }
cienaCesBenchmarkEntityEntryNumTestInstancesConfigured OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of test instances currently configured
on this entity."
::= { cienaCesBenchmarkEntityEntry 15 }
cienaCesBenchmarkEntityEntryNumTestInstancesEnabled OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of test instances currently enabled."
::= { cienaCesBenchmarkEntityEntry 16 }
cienaCesBenchmarkEntityEntryGenNumTestInstancesRunning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of test instances currently running."
::= { cienaCesBenchmarkEntityEntry 17 }
cienaCesBenchmarkEntityEntryBwAvailable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Bandwidth available for test traffic if
a reflector. Bandwidth remaining for other
test instances to be started if a generator."
::= { cienaCesBenchmarkEntityEntry 18 }
cienaCesBenchmarkEntityEntryGenBwUsedByRunningTests OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Bandwidth currently used by test instances
currently running, in Mbps."
::= { cienaCesBenchmarkEntityEntry 19 }
cienaCesBenchmarkEntityEntryAvailableHwSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum number of simultaneous hardware sessions available
on this platform."
::= { cienaCesBenchmarkEntityEntry 20 }
cienaCesBenchmarkEntityEntryAllocatedHwSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of allocated hardware sessions"
::= { cienaCesBenchmarkEntityEntry 21 }
cienaCesBenchmarkEntityEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to
'destroy'. If the entry exists, it is displayed
as 'active'."
::= { cienaCesBenchmarkEntityEntry 22 }
cienaCesBenchmarkEntityEntryClearStats OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set to true to clear all global fpga counters for the given entity.
Clear is only allowed for a reflector if no test instances are
enabled, and for a generator if no test instances are running. The
value is reset to false once the transaction is completed."
::= { cienaCesBenchmarkEntityEntry 23 }
cienaCesBenchmarkEntityEntryReflectorMacValidation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is only valid for the reflector entity and indicates
whether the reflector verifies that the destination MAC of the test
frames matches the MAC address associated with benchamrk reflector
entity. MAC Validation can only be disabled (False) in out-if-service or
evc/vid-out-of-service mode."
::= { cienaCesBenchmarkEntityEntry 24 }
--
-- BENCHMARK Entity Stats table
--
cienaCesBenchmarkEntityStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEntityStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of benchmark entity statistics entries."
::= { cienaCesBenchmarkModule 3 }
cienaCesBenchmarkEntityStatsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEntityStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK Entity characteristics."
INDEX { cienaCesBenchmarkEntityEntryId }
::= { cienaCesBenchmarkEntityStatsTable 1 }
CienaCesBenchmarkEntityStatsEntry ::= SEQUENCE {
cienaCesBenchmarkEntityStatsEntryClear TruthValue,
cienaCesBenchmarkEntityStatsEntryPortTxBytes Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxCrcErrorPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxUcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxMcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxBcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxUndersizePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxOversizePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxFragmentsPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxJabbersPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxPausePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxDropPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxDiscardPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTxLOutRangePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx64OctsPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx65To127Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx128To255Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx256To511Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx512To1023Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx1024To1518Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx1519To2047Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx2048To4095Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortTx4096To9216Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxBytes Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxExDeferPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxDeferPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxGiantPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxUnderRunPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxCrcErrorPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxLCheckErrorPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxLOutRangePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxPausePkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxUcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxMcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRxBcastPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx64OctsPkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx65To127Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx128To255Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx256To511Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx512To1023Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx1024To1518Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx1519To2047Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx2048To4095Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryPortRx4096To9216Pkts Counter64,
cienaCesBenchmarkEntityStatsEntryFpgaMissClassPkts Counter64,
cienaCesBenchmarkEntityStatsEntryFpgaCrcErrPkts Counter64,
cienaCesBenchmarkEntityStatsEntryFpgaUdpChkSumErrPkts Counter64
}
cienaCesBenchmarkEntityStatsEntryClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Set to true to clear all port and/or global fpga
counters for the given entity. Clear is only allowed
for a reflector if no test instances are enabled, and
for a generator if no test instances are running.
The value is reset to False once the transaction is completed.
This has been obsoleted by cienaCesBenchmarkEntityEntryClearStats."
::= { cienaCesBenchmarkEntityStatsEntry 1 }
cienaCesBenchmarkEntityStatsEntryPortTxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes transmitted by the benchmark port"
::= { cienaCesBenchmarkEntityStatsEntry 2 }
cienaCesBenchmarkEntityStatsEntryPortTxPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets transmitted by the benchmark port"
::= { cienaCesBenchmarkEntityStatsEntry 3 }
cienaCesBenchmarkEntityStatsEntryPortTxCrcErrorPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets with CRC errors"
::= { cienaCesBenchmarkEntityStatsEntry 4 }
cienaCesBenchmarkEntityStatsEntryPortTxUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unicast packets transmitted by the benchmark port"
::= { cienaCesBenchmarkEntityStatsEntry 5 }
cienaCesBenchmarkEntityStatsEntryPortTxMcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of multicast packets transmitted by the benchmark port"
::= { cienaCesBenchmarkEntityStatsEntry 6 }
cienaCesBenchmarkEntityStatsEntryPortTxBcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of broadcast packets transmitted by the benchmark port"
::= { cienaCesBenchmarkEntityStatsEntry 7 }
cienaCesBenchmarkEntityStatsEntryPortRxUndersizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { cienaCesBenchmarkEntityStatsEntry 8 }
cienaCesBenchmarkEntityStatsEntryPortRxOversizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { cienaCesBenchmarkEntityStatsEntry 9 }
cienaCesBenchmarkEntityStatsEntryPortRxFragmentsPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less
than 64 octets in length (excluding framing bits but
including FCS octets) and had either a bad Frame
Check Sequence (FCS) with an integral number of
octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error)."
::= { cienaCesBenchmarkEntityStatsEntry 10 }
cienaCesBenchmarkEntityStatsEntryPortRxJabbersPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error)."
::= { cienaCesBenchmarkEntityStatsEntry 11 }
cienaCesBenchmarkEntityStatsEntryPortTxPausePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit pause packets for the port."
::= { cienaCesBenchmarkEntityStatsEntry 12 }
cienaCesBenchmarkEntityStatsEntryPortTxDropPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of dropped packets on the benchmark port when
traffic profiles are enabled (311v only)."
::= { cienaCesBenchmarkEntityStatsEntry 13 }
cienaCesBenchmarkEntityStatsEntryPortTxDiscardPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of discarded packets."
::= { cienaCesBenchmarkEntityStatsEntry 14 }
cienaCesBenchmarkEntityStatsEntryPortTxLOutRangePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit length out of range packet count."
::= { cienaCesBenchmarkEntityStatsEntry 15 }
cienaCesBenchmarkEntityStatsEntryPortTx64OctsPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 64-byte packets transmitted on the benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 16 }
cienaCesBenchmarkEntityStatsEntryPortTx65To127Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 64 to 127-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 17 }
cienaCesBenchmarkEntityStatsEntryPortTx128To255Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 128 to 255-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 18 }
cienaCesBenchmarkEntityStatsEntryPortTx256To511Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 256 to 511-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 19 }
cienaCesBenchmarkEntityStatsEntryPortTx512To1023Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 512 to 1023-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 20 }
cienaCesBenchmarkEntityStatsEntryPortTx1024To1518Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 1024 to 1518-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 21 }
cienaCesBenchmarkEntityStatsEntryPortTx1519To2047Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 1519 to 2047-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 22 }
cienaCesBenchmarkEntityStatsEntryPortTx2048To4095Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 2048 to 4095-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 23 }
cienaCesBenchmarkEntityStatsEntryPortTx4096To9216Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of 4096 to 9216-byte packets transmitted on the
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 24 }
cienaCesBenchmarkEntityStatsEntryPortRxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes received on the benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 25 }
cienaCesBenchmarkEntityStatsEntryPortRxPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets received on the benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 26 }
cienaCesBenchmarkEntityStatsEntryPortRxExDeferPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of excessive deferred packets."
::= { cienaCesBenchmarkEntityStatsEntry 27 }
cienaCesBenchmarkEntityStatsEntryPortRxDeferPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of deferred packets."
::= { cienaCesBenchmarkEntityStatsEntry 28 }
cienaCesBenchmarkEntityStatsEntryPortRxGiantPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of too big packets."
::= { cienaCesBenchmarkEntityStatsEntry 29 }
cienaCesBenchmarkEntityStatsEntryPortRxUnderRunPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Underrun packet count for the benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 30 }
cienaCesBenchmarkEntityStatsEntryPortRxCrcErrorPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets received with CRC errors."
::= { cienaCesBenchmarkEntityStatsEntry 31 }
cienaCesBenchmarkEntityStatsEntryPortRxLCheckErrorPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets with length check errors."
::= { cienaCesBenchmarkEntityStatsEntry 32 }
cienaCesBenchmarkEntityStatsEntryPortRxLOutRangePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the benchmark port
that exceeded the maximum permitted frame size."
::= { cienaCesBenchmarkEntityStatsEntry 33 }
cienaCesBenchmarkEntityStatsEntryPortRxPausePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total receive pause packets for the port."
::= { cienaCesBenchmarkEntityStatsEntry 34 }
cienaCesBenchmarkEntityStatsEntryPortRxUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unicast packets received by benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 35 }
cienaCesBenchmarkEntityStatsEntryPortRxMcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of multicast packets received by benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 36 }
cienaCesBenchmarkEntityStatsEntryPortRxBcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of broadcast packets received by benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 37 }
cienaCesBenchmarkEntityStatsEntryPortRx64OctsPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 64-byte packets received by benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 38 }
cienaCesBenchmarkEntityStatsEntryPortRx65To127Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 65 to 127-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 39 }
cienaCesBenchmarkEntityStatsEntryPortRx128To255Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 128 to 255-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 40 }
cienaCesBenchmarkEntityStatsEntryPortRx256To511Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 256 to 511-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 41 }
cienaCesBenchmarkEntityStatsEntryPortRx512To1023Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 512 to 1023-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 42 }
cienaCesBenchmarkEntityStatsEntryPortRx1024To1518Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 1024 to 1518-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 43 }
cienaCesBenchmarkEntityStatsEntryPortRx1519To2047Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 1519 to 2047-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 44 }
cienaCesBenchmarkEntityStatsEntryPortRx2048To4095Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 2048 to 4095-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 45 }
cienaCesBenchmarkEntityStatsEntryPortRx4096To9216Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of 4096 to 9216-byte packets received by
benchmark port."
::= { cienaCesBenchmarkEntityStatsEntry 46 }
cienaCesBenchmarkEntityStatsEntryFpgaMissClassPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test packets received that didn't match any enabled
test session."
::= { cienaCesBenchmarkEntityStatsEntry 47 }
cienaCesBenchmarkEntityStatsEntryFpgaCrcErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test packets received with CRC errors"
::= { cienaCesBenchmarkEntityStatsEntry 48 }
cienaCesBenchmarkEntityStatsEntryFpgaUdpChkSumErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test packets received with UDP checksum errors"
::= { cienaCesBenchmarkEntityStatsEntry 49 }
--
-- EMIX Sequence Table
--
cienaCesBenchmarkEmixSequenceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEmixSequenceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of configured EMIX sequences
on this node."
::= { cienaCesBenchmarkModule 4 }
cienaCesBenchmarkEmixSequenceEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEmixSequenceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMIX sequence entry."
INDEX { cienaCesBenchmarkEmixSequenceId }
::= { cienaCesBenchmarkEmixSequenceTable 1 }
CienaCesBenchmarkEmixSequenceEntry ::= SEQUENCE {
cienaCesBenchmarkEmixSequenceId Integer32,
cienaCesBenchmarkEmixSequenceName DisplayString,
cienaCesBenchmarkEmixSequence DisplayString,
cienaCesBenchmarkEmixSequenceUFrameSize Integer32,
cienaCesBenchmarkEmixSequenceNumOfRef Integer32,
cienaCesBenchmarkEmixSequenceUserCreated TruthValue,
cienaCesBenchmarkEmixSequenceRowStatus RowStatus
}
cienaCesBenchmarkEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Id of the EMIX sequence entry"
::= { cienaCesBenchmarkEmixSequenceEntry 1 }
cienaCesBenchmarkEmixSequenceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of this EMIX sequence"
::= { cienaCesBenchmarkEmixSequenceEntry 2 }
cienaCesBenchmarkEmixSequence OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "EMIX sequence which is a sequence of up to
16 letters from the following set, that can
be repeated, where each letter is associated with
the frame size below it:
a b c d e f g h u v w x
64 128 256 512 1024 1280 1518 MTU custom 84 68 88
The u frame size is user configurable via the
cienaCesBenchmarkEmixSequenceUFrameSize attribute
while the h frame size is the maximum frame size
configured at the entity level. If the h frame size is
not configured at the entity level, h takes the value of
the maximum frame size of the port under test.
Letter v is the minimum frame size for IPv6 untagged or dot1q
test frames, w is the minimum for IPv4 qinq test frames, and
x is the minimum for IPv6 qinq test frames.
The EMIX character set is available via table
cienaCesBenchmarkEmixCharacterSetTable."
::= { cienaCesBenchmarkEmixSequenceEntry 3 }
cienaCesBenchmarkEmixSequenceUFrameSize OBJECT-TYPE
SYNTAX Integer32 (64..9216)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The frame size associated with the u letter
in the given sequence. The default value is
594."
::= { cienaCesBenchmarkEmixSequenceEntry 4 }
cienaCesBenchmarkEmixSequenceNumOfRef OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of generator test profiles currently
using this EMIX sequence for testing.
If this is the default EMIX sequence
set in the generator, that also count
as one reference."
::= { cienaCesBenchmarkEmixSequenceEntry 5 }
cienaCesBenchmarkEmixSequenceUserCreated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Flag indicating whether this sequence was
created by the user or by the system at
initialization. Only user created sequences
are editable."
::= { cienaCesBenchmarkEmixSequenceEntry 6 }
cienaCesBenchmarkEmixSequenceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to
'destroy'. If the entry exists, it is displayed
as 'active'."
::= { cienaCesBenchmarkEmixSequenceEntry 7 }
---
--- EMIX Sequence Frame Size Table per Entity
---
cienaCesBenchmarkEmixFrameSizeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEmixFrameSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of frame sizes associated
with the specified EMIX sequence Id."
::= { cienaCesBenchmarkModule 5 }
cienaCesBenchmarkEmixFrameSizeEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEmixFrameSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Frame size associated with given EMIX
sequence ID and frame size index on a given Entity"
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkEmixSequenceId,
cienaCesBenchmarkEmixFrameSizeIndex }
::= { cienaCesBenchmarkEmixFrameSizeTable 1 }
CienaCesBenchmarkEmixFrameSizeEntry ::= SEQUENCE {
cienaCesBenchmarkEmixFrameSizeIndex Integer32,
cienaCesBenchmarkEmixFrameSizeEntryFrameSize Integer32
}
cienaCesBenchmarkEmixFrameSizeIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index of frame size in array of frame sizes
for the given EMIX sequence."
::= { cienaCesBenchmarkEmixFrameSizeEntry 1 }
cienaCesBenchmarkEmixFrameSizeEntryFrameSize OBJECT-TYPE
SYNTAX Integer32 (64..9216)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frame size associated with the letter at the
position given by cienaCesBenchmarkEmixFrameSizeIndex
in the EMIX sequence with Id
cienaCesBenchmarkEmixSequenceId."
::= { cienaCesBenchmarkEmixFrameSizeEntry 2 }
---
--- EMIX Sequence Average Frame Size per Generator Entity
---
cienaCesBenchmarkEmixAvgFrameSizeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEmixAvgFrameSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the average frame size associated
with the specified EMIX sequence Id on a given Entity."
::= { cienaCesBenchmarkModule 6 }
cienaCesBenchmarkEmixAvgFrameSizeEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEmixAvgFrameSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Average frame size associated with given EMIX
sequence ID and Entity. Only valid for Generator
entities."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkEmixSequenceId }
::= { cienaCesBenchmarkEmixAvgFrameSizeTable 1 }
CienaCesBenchmarkEmixAvgFrameSizeEntry ::= SEQUENCE {
cienaCesBenchmarkEmixAvgFrameSize Integer32
}
cienaCesBenchmarkEmixAvgFrameSize OBJECT-TYPE
SYNTAX Integer32 (64..9216)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Average frame size for the EMIX sequence with
Id cienaCesBenchmarkEmixSequenceId on the
generator entity with Id cienaCesBenchmarkEntityEntryId."
::= { cienaCesBenchmarkEmixAvgFrameSizeEntry 1 }
---
--- KPI Profile Table
---
cienaCesBenchmarkKpiProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkKpiProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of configured Key Performance
Indicator profiles on this node."
::= { cienaCesBenchmarkModule 7 }
cienaCesBenchmarkKpiProfileEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Hw session allocation entry."
INDEX { cienaCesBenchmarkKpiProfileId }
::= { cienaCesBenchmarkKpiProfileTable 1 }
CienaCesBenchmarkKpiProfileEntry ::= SEQUENCE {
cienaCesBenchmarkKpiProfileId Integer32,
cienaCesBenchmarkKpiProfileName DisplayString,
cienaCesBenchmarkKpiProfileNumOfRef Integer32,
cienaCesBenchmarkKpiProfileRowStatus RowStatus
}
cienaCesBenchmarkKpiProfileId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Id of the KPI profile entry"
::= { cienaCesBenchmarkKpiProfileEntry 1 }
cienaCesBenchmarkKpiProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of a the KPI profile"
::= { cienaCesBenchmarkKpiProfileEntry 2 }
cienaCesBenchmarkKpiProfileNumOfRef OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of generator test profiles currently
using this KPI profile for results analysis.
If this is the default KPI profile set in
the generator, that also count as one reference."
::= { cienaCesBenchmarkKpiProfileEntry 3 }
cienaCesBenchmarkKpiProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to
'destroy'. If the entry exists, it is displayed
as 'active'."
::= { cienaCesBenchmarkKpiProfileEntry 4 }
---
--- KPI value per PCP per Color Table
---
cienaCesBenchmarkKpiPcpColorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkKpiPcpColorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of configured Key Performance
Indicator per KPI profile, per PCP and per Color."
::= { cienaCesBenchmarkModule 8 }
cienaCesBenchmarkKpiPcpColorEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiPcpColorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry for the KPI values for the given KPI profile,
PCP and color."
INDEX { cienaCesBenchmarkKpiProfileId,
cienaCesBenchmarkKpiPcpIndex,
cienaCesBenchmarkKpiColorIndex }
::= { cienaCesBenchmarkKpiPcpColorTable 1 }
CienaCesBenchmarkKpiPcpColorEntry ::= SEQUENCE {
cienaCesBenchmarkKpiPcpIndex Integer32,
cienaCesBenchmarkKpiColorIndex Integer32,
cienaCesBenchmarkKpiPcp Integer32,
cienaCesBenchmarkKpiColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkKpiThroughput CienaCesBenchmarkThroughputKpiPercent,
cienaCesBenchmarkKpiFrameloss CienaCesBenchmarkFramelossKpiPercent,
cienaCesBenchmarkKpiLatency Integer32,
cienaCesBenchmarkKpiPdv Integer32
}
cienaCesBenchmarkKpiPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index for the PCP"
::= { cienaCesBenchmarkKpiPcpColorEntry 1 }
cienaCesBenchmarkKpiColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index for the PCP"
::= { cienaCesBenchmarkKpiPcpColorEntry 2 }
cienaCesBenchmarkKpiPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PCP value associated with this entry"
::= { cienaCesBenchmarkKpiPcpColorEntry 3 }
cienaCesBenchmarkKpiColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Traffic color, green or yellow, associated with these
KPIs."
::= { cienaCesBenchmarkKpiPcpColorEntry 4 }
cienaCesBenchmarkKpiThroughput OBJECT-TYPE
SYNTAX CienaCesBenchmarkThroughputKpiPercent
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Throughput KPI for the given KPI profile, PCP and color
expressed in percent of bandwidth * 10000 to provide a 4
decimal point value."
::= { cienaCesBenchmarkKpiPcpColorEntry 5 }
cienaCesBenchmarkKpiFrameloss OBJECT-TYPE
SYNTAX CienaCesBenchmarkFramelossKpiPercent
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Frameloss KPI for the given KPI profile, PCP and color
expressed in percent of bandwidth * 10000 to provide a 4
decimal point value."
::= { cienaCesBenchmarkKpiPcpColorEntry 6 }
cienaCesBenchmarkKpiLatency OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum latency in micro-seconds that the latency result
should not exceed in order for the test to be considered
a pass."
::= { cienaCesBenchmarkKpiPcpColorEntry 7 }
cienaCesBenchmarkKpiPdv OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum PDV in micro-seconds that the PDV test result
should not exceed in order for the test to be
considered a pass."
::= { cienaCesBenchmarkKpiPcpColorEntry 8 }
---
--- Bandwidth Allocation Profile Table
---
cienaCesBenchmarkBwAllocProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkBwAllocProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of configured bandwidth
allocation profiles on this node."
::= { cienaCesBenchmarkModule 9 }
cienaCesBenchmarkBwAllocProfileEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkBwAllocProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BW allocation profile entry"
INDEX { cienaCesBenchmarkBwAllocProfileId }
::= { cienaCesBenchmarkBwAllocProfileTable 1 }
CienaCesBenchmarkBwAllocProfileEntry ::= SEQUENCE {
cienaCesBenchmarkBwAllocProfileId Integer32,
cienaCesBenchmarkBwAllocProfileName DisplayString,
cienaCesBenchmarkBwAllocProfileNumOfRef Integer32,
cienaCesBenchmarkBwAllocProfileRowStatus RowStatus
}
cienaCesBenchmarkBwAllocProfileId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Id of the bandwidth allocation
profile entry"
::= { cienaCesBenchmarkBwAllocProfileEntry 1 }
cienaCesBenchmarkBwAllocProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of a the bandwidth allocation
profile"
::= { cienaCesBenchmarkBwAllocProfileEntry 2 }
cienaCesBenchmarkBwAllocProfileNumOfRef OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of generator test profiles currently
using this bandwidth allocation profile
for testing.
If this is the default BW allocation
profile set in the generator, that also count
as one reference."
::= { cienaCesBenchmarkBwAllocProfileEntry 3 }
cienaCesBenchmarkBwAllocProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to
'destroy'. If the entry exists, it is displayed
as 'active'."
::= { cienaCesBenchmarkBwAllocProfileEntry 4 }
---
--- BW allocation value per profile per PCP
---
cienaCesBenchmarkBwRatioTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkBwRatioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the list of configured bandwidth
ratio per profile, per PCP."
::= { cienaCesBenchmarkModule 10 }
cienaCesBenchmarkBwRatioEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkBwRatioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry for bandwidth percent per BW Allocation
profile and PCP"
INDEX { cienaCesBenchmarkBwAllocProfileId,
cienaCesBenchmarkBwRatioPcpIndex }
::= { cienaCesBenchmarkBwRatioTable 1 }
CienaCesBenchmarkBwRatioEntry ::= SEQUENCE {
cienaCesBenchmarkBwRatioPcpIndex Integer32,
cienaCesBenchmarkBwRatioPcp Integer32,
cienaCesBenchmarkBwRatio Integer32
}
cienaCesBenchmarkBwRatioPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index for the PCP"
::= { cienaCesBenchmarkBwRatioEntry 1 }
cienaCesBenchmarkBwRatioPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PCP value associated with this entry."
::= { cienaCesBenchmarkBwRatioEntry 2 }
cienaCesBenchmarkBwRatio OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Ratio of test bandwidth to allocate to the
test session with this PCP value."
::= { cienaCesBenchmarkBwRatioEntry 3 }
--
-- BENCHMARK Profile table
--
cienaCesBenchmarkProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of profile entries."
::= { cienaCesBenchmarkModule 11 }
cienaCesBenchmarkProfileEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK Profile characteristics."
INDEX { cienaCesBenchmarkProfileEntryId }
::= { cienaCesBenchmarkProfileTable 1 }
CienaCesBenchmarkProfileEntry ::= SEQUENCE {
cienaCesBenchmarkProfileEntryId Integer32,
cienaCesBenchmarkProfileEntryName DisplayString,
-- Configuration parameters
cienaCesBenchmarkProfileEntryBandwidth Integer32,
cienaCesBenchmarkProfileEntryExcessBandwidth Integer32,
cienaCesBenchmarkProfileEntryInterval INTEGER,
cienaCesBenchmarkProfileEntryDuration INTEGER,
cienaCesBenchmarkProfileEntrySetFrameSizeList DisplayString,
cienaCesBenchmarkProfileEntryMaxSearches Integer32,
cienaCesBenchmarkProfileEntryMaxSamples Integer32,
cienaCesBenchmarkProfileEntrySamplingInterval Integer32,
cienaCesBenchmarkProfileEntryFrameLossStartBw INTEGER,
cienaCesBenchmarkProfileEntryVidValidation TruthValue,
cienaCesBenchmarkProfileEntryPcpValidation TruthValue,
cienaCesBenchmarkProfileEntryColorValidation TruthValue,
cienaCesBenchmarkProfileEntryKpiProfileId Integer32,
cienaCesBenchmarkProfileEntryBwAllocProfileId Integer32,
cienaCesBenchmarkProfileEntryEmixSequenceId Integer32,
-- Payload parameters
cienaCesBenchmarkProfileEntryEncapType INTEGER,
cienaCesBenchmarkProfileEntryPduType INTEGER,
cienaCesBenchmarkProfileEntryDstmac MacAddress,
cienaCesBenchmarkProfileEntrySVid Integer32,
cienaCesBenchmarkProfileEntrySPcp CienaCesBenchmarkPcpBitmap,
cienaCesBenchmarkProfileEntrySColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkProfileEntryCVid Integer32,
cienaCesBenchmarkProfileEntryCPcp CienaCesBenchmarkPcpBitmap,
cienaCesBenchmarkProfileEntryCColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkProfileEntryTpid Integer32,
cienaCesBenchmarkProfileEntryDscp Integer32,
cienaCesBenchmarkProfileEntrySrcInetAddrType InetAddressType,
cienaCesBenchmarkProfileEntrySrcInetAddr InetAddress,
cienaCesBenchmarkProfileEntryDstInetAddrType InetAddressType,
cienaCesBenchmarkProfileEntryDstInetAddr InetAddress,
cienaCesBenchmarkProfileEntryCustomPayload OCTET STRING,
-- Traffic test parameters
cienaCesBenchmarkProfileEntryThroughputTest TruthValue,
cienaCesBenchmarkProfileEntryFramelossTest TruthValue,
cienaCesBenchmarkProfileEntryLatencyTest TruthValue,
cienaCesBenchmarkProfileEntryPdvTest TruthValue,
cienaCesBenchmarkProfileEntryBurstTest TruthValue,
cienaCesBenchmarkProfileEntryRfc2544Suite TruthValue,
cienaCesBenchmarkProfileEntryY1564Test TruthValue,
-- Operational status
cienaCesBenchmarkProfileEntryHwSessionsRequired Integer32,
cienaCesBenchmarkProfileEntryNumOfRef Integer32,
cienaCesBenchmarkProfileEntryRowStatus RowStatus
}
cienaCesBenchmarkProfileEntryId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for BENCHMARK profile records."
::= { cienaCesBenchmarkProfileEntry 1 }
cienaCesBenchmarkProfileEntryName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the profile as entered when created."
::= { cienaCesBenchmarkProfileEntry 2 }
cienaCesBenchmarkProfileEntryBandwidth OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum bandwidth to use when generating green test
traffic for the profile."
::= { cienaCesBenchmarkProfileEntry 3 }
cienaCesBenchmarkProfileEntryExcessBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Maximum bandwidth to use when generating yellow test
traffic for the profile. When testing for red color,
this bandwidth is multiplied by 1.25"
DEFVAL { 0 }
::= { cienaCesBenchmarkProfileEntry 4 }
cienaCesBenchmarkProfileEntryInterval OBJECT-TYPE
SYNTAX INTEGER {
t15min(1),
t1hr(2),
t6hr(3),
tCompletion(4),
t2hr(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval between the start of one test group to the start
of the next test group."
DEFVAL { tCompletion }
::= { cienaCesBenchmarkProfileEntry 5 }
cienaCesBenchmarkProfileEntryDuration OBJECT-TYPE
SYNTAX INTEGER {
t15min(1),
t1hr(2),
t6hr(3),
t24hr(4),
tIndefinite(5),
tOnce(6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Duration of the testing. The test group is repeated until
the duration ends. When indefinite is set, test group is
run only once to completion"
DEFVAL { tOnce }
::= { cienaCesBenchmarkProfileEntry 6 }
cienaCesBenchmarkProfileEntrySetFrameSizeList OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to replace the existing frame size table with the specified list.
More than one values can be listed and are separated by commas."
::= { cienaCesBenchmarkProfileEntry 7 }
cienaCesBenchmarkProfileEntryMaxSearches OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For the throughput test, this is the maximum number of
searches to find a transmit rate without drops for a
given frame size."
DEFVAL { 7 }
::= { cienaCesBenchmarkProfileEntry 8 }
cienaCesBenchmarkProfileEntryMaxSamples OBJECT-TYPE
SYNTAX Integer32 (2..20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For the latency and PDV tests, this is the number of
samples to take in order to determine the min, avg
and max latency and avg PDV."
DEFVAL { 10 }
::= { cienaCesBenchmarkProfileEntry 9 }
cienaCesBenchmarkProfileEntrySamplingInterval OBJECT-TYPE
SYNTAX Integer32 (1..600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For the latency and PDV tests, this is the interval,
in 100ms, to wait between samples."
DEFVAL { 1 }
::= { cienaCesBenchmarkProfileEntry 10 }
cienaCesBenchmarkProfileEntryFrameLossStartBw OBJECT-TYPE
SYNTAX INTEGER {
profileBandwidth(1),
maximumThroughput(2),
maximumLineRate(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For the frame loss test, this indicates which bandwidth
value to use as the starting bandwidth; the maximum
bandwidth determined via the throughput test, the
bandwidth parameter configured in the profile, or
the maximum bandwidth of the link.
The value maximumLineRate(3) is not supported."
DEFVAL { maximumThroughput }
::= { cienaCesBenchmarkProfileEntry 11 }
cienaCesBenchmarkProfileEntryVidValidation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether VID validation is performed in
the classifier or not on the returning packet. If vid
validation is set to false, PCP and Color validation are
ignored and automatically become false."
DEFVAL { true }
::= { cienaCesBenchmarkProfileEntry 12 }
cienaCesBenchmarkProfileEntryPcpValidation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to indicate whether the PCP value of the
test packet should be used to classifier the reflected
packets or not. When color remarking is used, this should
be set to false. Default is true."
DEFVAL { true }
::= { cienaCesBenchmarkProfileEntry 13 }
cienaCesBenchmarkProfileEntryColorValidation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to indicate whether the color bit of the
test packet should be used to classifier the reflected
packets or not. In color unaware testing, this should
be set to false. Default is true."
DEFVAL { true }
::= { cienaCesBenchmarkProfileEntry 14 }
cienaCesBenchmarkProfileEntryKpiProfileId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Name of a valid KPI profile, from the
cienaCesBenchmarkKpiProfileTable, to use when
analysing the test results for this profile."
::= { cienaCesBenchmarkProfileEntry 15 }
cienaCesBenchmarkProfileEntryBwAllocProfileId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Id of a valid Bandwidth Allocation profile,
from the cienaCesBenchmarkBwAllocProfileTable,
used for distributing the profile bandwidth amongst
the configured PCP values for this profile when running
tests."
::= { cienaCesBenchmarkProfileEntry 16 }
cienaCesBenchmarkProfileEntryEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Id of a valid EMIX sequence configured in the
cienaCesBenchmarkEmixSequenceTable, to use when y1564
is selected. The EMIX sequence is used instead of the
frame size list if and only if y1564 is selected."
::= { cienaCesBenchmarkProfileEntry 17 }
cienaCesBenchmarkProfileEntryEncapType OBJECT-TYPE
SYNTAX INTEGER {
untagged(1),
dot1q(2),
qinq(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation type to use for generated packets."
DEFVAL { untagged }
::= { cienaCesBenchmarkProfileEntry 18 }
cienaCesBenchmarkProfileEntryPduType OBJECT-TYPE
SYNTAX INTEGER {
ethernet(1),
ip(2),
udpecho(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vlan tag protocol identifier to use for the generated packets."
DEFVAL { ethernet }
::= { cienaCesBenchmarkProfileEntry 19 }
cienaCesBenchmarkProfileEntryDstmac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MAC address to use as the destination MAC address on
the generated packets."
::= { cienaCesBenchmarkProfileEntry 20 }
cienaCesBenchmarkProfileEntrySVid OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"S-VLAN ID to used for generated packets when encapType is set to QinQ"
::= { cienaCesBenchmarkProfileEntry 21 }
cienaCesBenchmarkProfileEntrySPcp OBJECT-TYPE
SYNTAX CienaCesBenchmarkPcpBitmap
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bitmap of the S-VLAN PCP (Priority Code Point) value to
test with. When RFC2544 test is enabled, only one
PCP can be set in the mask. Otherwise, a test session
will be run for each PCP bit set. Used when the encapType
set to QinQ"
DEFVAL { pcp0 }
::= { cienaCesBenchmarkProfileEntry 22 }
cienaCesBenchmarkProfileEntrySColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Color of the S-VLAN tag for the test traffic. This is
directly related to the value of the DEI bit
configured in the VLAN tag of the test traffic. Green
traffic will have its DEI bit set to 0 while Yellow
traffic will have its DEI bit set to 1.
Green test traffic is generated based on the bandwidth
configured in the test profile. Yellow traffic is
generated based on the excess-bandwidth parameter.
Finally, if the user selects green-yellow-red, the
yellow traffic is generated at 1.25 * excess-bandwidth.
This is used only when encapType is set to QinQ"
::= { cienaCesBenchmarkProfileEntry 23 }
cienaCesBenchmarkProfileEntryCVid OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"C-VLAN ID to used for generated packets when encapType is set to
QinQ or dot1q."
::= { cienaCesBenchmarkProfileEntry 24 }
cienaCesBenchmarkProfileEntryCPcp OBJECT-TYPE
SYNTAX CienaCesBenchmarkPcpBitmap
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bitmap of the C-VLAN PCP (Priority Code Point) value to
test with. When RFC2544 test is enabled, only one
PCP can be set in the mask. Otherwise, a test session
will be run for each PCP bit set. Only used when the
encapType is set to dot1q. In the QinQ type, the c-pcp
of the test packet takes the same value as the s-pcp to
simplify software."
DEFVAL { pcp0 }
::= { cienaCesBenchmarkProfileEntry 25 }
cienaCesBenchmarkProfileEntryCColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Color of the C-VLAN tag for the test traffic. This is
directly related to the value of the DEI bit
configured in the VLAN tag of the test traffic. Green
traffic will have its DEI bit set to 0 while Yellow
traffic will have its DEI bit set to 1.
Green test traffic is generated based on the bandwidth
configured in the test profile. Yellow traffic is
generated based on the excess-bandwidth parameter.
Finally, if the user selects green-yellow-red, the
yellow traffic is generated at 1.25 * excess-bandwidth.
This is used only when encapType is set to dot1q.
In a QinQ configuration, the c-dei bit is set to the
same value as the s-dei bit in order to simplify
software."
::= { cienaCesBenchmarkProfileEntry 26 }
cienaCesBenchmarkProfileEntryTpid OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vlan tag protocol identifier to use for the generated packets.
The following TPID values are supported by benchmark:
0x8100
0x9100
0x88A8"
DEFVAL { 33024 }
::= { cienaCesBenchmarkProfileEntry 27 }
cienaCesBenchmarkProfileEntryDscp OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP DSCP value to use for the generated packets."
DEFVAL { 0 }
::= { cienaCesBenchmarkProfileEntry 28 }
cienaCesBenchmarkProfileEntrySrcInetAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the type of address cienaCesBenchmarkProfileEntrySrcInetAddr belongs to.
When set to:
ipv4 : cienaCesBenchmarkProfileEntrySrcInetAddr should be compliant with
InetAddressIPv4 from RFC 4001
ipv6 : cienaCesBenchmarkProfileEntrySrcInetAddr should be compliant with
InetAddressIPv6 from RFC 4001.
The InetAddressType and the InetAddress must be set as part of the same SNMP
SET request."
::= { cienaCesBenchmarkProfileEntry 29 }
cienaCesBenchmarkProfileEntrySrcInetAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the unicast source IP address to use in IP test packet.
The InetAddress specified here is compliant with RFC 4001.
The InetAddressType and the InetAddress must be set as part of the same SNMP
SET request."
::= { cienaCesBenchmarkProfileEntry 30 }
cienaCesBenchmarkProfileEntryDstInetAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the type of address cienaCesBenchmarkProfileEntryDstInetAddr belongs to.
When set to:
ipv4 : cienaCesBenchmarkProfileEntryDstInetAddr should be compliant with
InetAddressIPv4 from RFC 4001
ipv6 : cienaCesBenchmarkProfileEntryDstInetAddr should be compliant with
InetAddressIPv6 from RFC 4001.
The InetAddressType and the InetAddress must be set as part of the same SNMP
SET request."
::= { cienaCesBenchmarkProfileEntry 31 }
cienaCesBenchmarkProfileEntryDstInetAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the unicast destination IP address to use in IP test packet.
The InetAddress specified here is compliant with RFC 4001.
The InetAddressType and the InetAddress must be set as part of the same SNMP
SET request."
::= { cienaCesBenchmarkProfileEntry 32 }
cienaCesBenchmarkProfileEntryCustomPayload OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Custom payload to be used on the generated packets."
::= { cienaCesBenchmarkProfileEntry 33 }
cienaCesBenchmarkProfileEntryThroughputTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Run throughput test"
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 34 }
cienaCesBenchmarkProfileEntryFramelossTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Run frame loss test"
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 35 }
cienaCesBenchmarkProfileEntryLatencyTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Run latency test"
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 36 }
cienaCesBenchmarkProfileEntryPdvTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Run packet delay variation test"
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 37 }
cienaCesBenchmarkProfileEntryBurstTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Run packet burst test"
::= { cienaCesBenchmarkProfileEntry 38 }
cienaCesBenchmarkProfileEntryRfc2544Suite OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Run RFC2544 test suite which includes throughput, frame
loss and latency tests"
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 39 }
cienaCesBenchmarkProfileEntryY1564Test OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Y1564 test includes the throughput, frameloss,
latency and PDV tests are is run using the configured
EMIX sequence. If the profile's EMIX sequence is
not configured, the default generator EMIX sequence is
used. Y1564 and RFC2544 are mutually exclusive."
DEFVAL { false }
::= { cienaCesBenchmarkProfileEntry 40 }
cienaCesBenchmarkProfileEntryHwSessionsRequired OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This represents the number of hardware sessions
required to enable/run a test instance using
this profile according to the profile's current
configuration.
One hardware session is required for each outer tag
PCP and color configured.
Ex 1) Encap type set to dot1q, c-pcp is 0,3 and
c-color is set to green, 2 PCPs * 1 color =
2 hw sessions.
Ex 2) Encap type set to qinq, s-pcp is 0,4,5 and
s-color is set to green-yellow, then you
need 3 PCPs * 2 colors = 6 hw sessions.
Ex 3) Encap type set to untagged, only 1 hw session
is required."
::= { cienaCesBenchmarkProfileEntry 41 }
cienaCesBenchmarkProfileEntryNumOfRef OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of generator test instances currently
using this test profile for testing."
::= { cienaCesBenchmarkProfileEntry 42 }
cienaCesBenchmarkProfileEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to manage the creation and deletion of the
conceptual rows in this table. To create a row in
this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to
'destroy'. If the entry exists, it is displayed
as 'active'."
::= { cienaCesBenchmarkProfileEntry 43 }
--
-- Test Instance Table
--
cienaCesBenchmarkTestInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkTestInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of test instance entries."
::= { cienaCesBenchmarkModule 12 }
cienaCesBenchmarkTestInstanceEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkTestInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK test instance characteristics."
INDEX { cienaCesBenchmarkTestInstanceEntryId }
::= { cienaCesBenchmarkTestInstanceTable 1 }
CienaCesBenchmarkTestInstanceEntry ::= SEQUENCE {
cienaCesBenchmarkTestInstanceEntryId Integer32,
cienaCesBenchmarkTestInstanceEntryName DisplayString,
cienaCesBenchmarkTestInstanceEntrySubPortId Integer32,
cienaCesBenchmarkTestInstanceEntryProfileId Integer32,
cienaCesBenchmarkTestInstanceEntrySvid Integer32,
cienaCesBenchmarkTestInstanceEntryCvid Integer32,
cienaCesBenchmarkTestInstanceEntryUntagged TruthValue,
cienaCesBenchmarkTestInstanceEntryDstMac MacAddress,
cienaCesBenchmarkTestInstanceEntryAdminState CienaCesBenchmarkAdminState,
cienaCesBenchmarkTestInstanceEntryStarted TruthValue,
cienaCesBenchmarkTestInstanceEntryCurrentInterval Integer32,
cienaCesBenchmarkTestInstanceEntryTotalIntervals Integer32,
cienaCesBenchmarkTestInstanceEntryLastIterStart DateAndTime,
cienaCesBenchmarkTestInstanceEntryClearStats TruthValue,
cienaCesBenchmarkTestInstanceEntryRowStatus RowStatus,
cienaCesBenchmarkTestInstanceEntryAssocEntityId Integer32
}
cienaCesBenchmarkTestInstanceEntryId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique identifier for the test instance."
::= { cienaCesBenchmarkTestInstanceEntry 1 }
cienaCesBenchmarkTestInstanceEntryName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..46))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Unique name given to the test instance at creation time."
::= { cienaCesBenchmarkTestInstanceEntry 2 }
cienaCesBenchmarkTestInstanceEntrySubPortId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ID of the sub-port to base this test instance on. The sub-port has
to be a child of the port under test associated with an existing
entity."
::= { cienaCesBenchmarkTestInstanceEntry 3 }
cienaCesBenchmarkTestInstanceEntryProfileId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Id of an existing test profile to be used with the test instance as
the template for testing. A test profile ID has to be specified if
this test instance is associated with a generator entity. If it's a
reflector test instance, a profile ID CANNOT be specified, it has
to remain set 0."
::= { cienaCesBenchmarkTestInstanceEntry 4 }
cienaCesBenchmarkTestInstanceEntrySvid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"S VLAN ID to use for testing.
For generator test instances, this over-writes the value defined in
the referenced test profile if applicable (encap-type set to qinq).
For reflector test instances, this has to be set to a valid s-vid
accepted by the associated sub-port. A value of 0xFFFF indicates ANY s-vid.
A value of 0 indicates untagged or single-tagged traffic."
::= { cienaCesBenchmarkTestInstanceEntry 5 }
cienaCesBenchmarkTestInstanceEntryCvid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"C VLAN ID to use for testing.
For generator test instances, this over-writes the value defined in the
referenced test profile if applicable (encap-type set to dot1q or qinq).
For reflector test instances, this has to be set to a valid c-vid
accepted by the associated sub-port. A value of 0xFFFF indicates ANY
c-vid, while a value of 0 indicates untagged (s-vid also has to be set
to 0)."
::= { cienaCesBenchmarkTestInstanceEntry 6 }
cienaCesBenchmarkTestInstanceEntryUntagged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When set to true, this indicates that the test instance
is to be associated with untagged data traffic. When this
is set, the cvid and svid parameters must be 0."
::= { cienaCesBenchmarkTestInstanceEntry 7 }
cienaCesBenchmarkTestInstanceEntryDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination MAC address to use for generator test instances. When set,
this over writes the value specified in the referenced test profile.
This field is not applicable for reflector test instances."
::= { cienaCesBenchmarkTestInstanceEntry 8 }
cienaCesBenchmarkTestInstanceEntryAdminState OBJECT-TYPE
SYNTAX CienaCesBenchmarkAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the administrative state of the test instance. Upon enabling
a test instance, resources are allocated in hardware. For reflector test
instances, this triggers the start of reflection of any test traffic
received that matches the specified svid:cvid combination on the
specified sub-port."
::= { cienaCesBenchmarkTestInstanceEntry 9 }
cienaCesBenchmarkTestInstanceEntryStarted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable to generator test instances, this indicates whether testing is
in progress or not. Setting this attribute to true will initiate
testing."
::= { cienaCesBenchmarkTestInstanceEntry 10 }
cienaCesBenchmarkTestInstanceEntryCurrentInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Applicable to generator test instances, this indicates the
number of intervals of the selected tests have been run,
including the current one, in relation to the total number of
intervals to complete. This is based on the profile's
interval and duration configured."
::= { cienaCesBenchmarkTestInstanceEntry 11 }
cienaCesBenchmarkTestInstanceEntryTotalIntervals OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Applicable to generator test instances, this indicates the
total number of intervals of the selected tests to be run
by a single start command on the test instance. This is
based on the profile's interval and duration configured.
A value of 0 should be interpreted as unknown and -1 as
indefinite."
::= { cienaCesBenchmarkTestInstanceEntry 12 }
cienaCesBenchmarkTestInstanceEntryLastIterStart OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date and time of the last iteration that started since the
last time the system was rebooted or the statistics were
cleared on the test instance."
::= { cienaCesBenchmarkTestInstanceEntry 13 }
cienaCesBenchmarkTestInstanceEntryClearStats OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set to true to clear the results and counters for the
test instance."
::= { cienaCesBenchmarkTestInstanceEntry 14 }
cienaCesBenchmarkTestInstanceEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to manage the creation and deletion of the conceptual rows in this table.
To create a row in this table, set this object to 'createAndGo'.
To delete a row in this table, set this object to 'destroy'.
If the entry exists, it is displayed as 'active'."
::= { cienaCesBenchmarkTestInstanceEntry 15 }
cienaCesBenchmarkTestInstanceEntryAssocEntityId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the entity this test instance is associated with
(cienaCesBenchmarkEntityEntryId)"
::= { cienaCesBenchmarkTestInstanceEntry 16 }
---
--- Generator Test Session Allocation and Status Table
---
cienaCesBenchmarkGenTestSessionAllocationTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkGenTestSessionAllocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing the allocation of hw test session per
generator test instance Id, PCP and color."
::= { cienaCesBenchmarkModule 13 }
cienaCesBenchmarkGenTestSessionAllocationEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkGenTestSessionAllocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Test session (aka hardware session) allocation entry.
SPECIAL NOTE: It is important to know that when the associated
test profile's encapsulation type is set to untagged,
the last two elements of the index (PCP and color) are fixed
at 1.1. The management software needs to query using index
<entidyId>.<testInstandceId>.1.1 in this case, since
PCP and color are irrelevant in the untagged test traffic
scenario."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkGenTestSessionPcpIndex,
cienaCesBenchmarkGenTestSessionColorIndex }
::= { cienaCesBenchmarkGenTestSessionAllocationTable 1 }
CienaCesBenchmarkGenTestSessionAllocationEntry ::= SEQUENCE {
cienaCesBenchmarkGenTestSessionPcpIndex Integer32,
cienaCesBenchmarkGenTestSessionColorIndex Integer32,
cienaCesBenchmarkGenTestSessionPcp Integer32,
cienaCesBenchmarkGenTestSessionColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkGenTestSessionId Integer32,
cienaCesBenchmarkGenTestSessionEmixSequenceId Integer32,
cienaCesBenchmarkGenTestSessionCurrentPktSize Integer32,
cienaCesBenchmarkGenTestSessionThroughputTestState CienaCesBenchmarkThroughputTestState,
cienaCesBenchmarkGenTestSessionFramelossTestState CienaCesBenchmarkFramelossTestState,
cienaCesBenchmarkGenTestSessionLatencyTestState CienaCesBenchmarkLatencyPdvTestState,
cienaCesBenchmarkGenTestSessionPdvTestState CienaCesBenchmarkLatencyPdvTestState,
cienaCesBenchmarkGenTestSessionRfc2544TestState CienaCesBenchmarkRfc2544TestState,
cienaCesBenchmarkGenTestSessionY1564TestState CienaCesBenchmarkY1564TestState,
cienaCesBenchmarkGenTestSessionCurrentRate Integer32,
cienaCesBenchmarkGenTestSessionSamplesCompleted Integer32
}
cienaCesBenchmarkGenTestSessionPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "PCP Index."
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 1 }
cienaCesBenchmarkGenTestSessionColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Color Index."
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 2 }
cienaCesBenchmarkGenTestSessionPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PCP value associated with this hw session"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 3 }
cienaCesBenchmarkGenTestSessionColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Color of test traffic associated with this hardware
session"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 4 }
cienaCesBenchmarkGenTestSessionId OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Id of the hardware session allocated to the given
test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 5 }
cienaCesBenchmarkGenTestSessionEmixSequenceId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "EMIX sequence Id used with this session. If zero,
it indicates that the the frame size list is being used
for the test and cienaCesBenchmarkGenTestSessionCurrentPktSize
indicates which packet size is currently being tested."
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 6 }
cienaCesBenchmarkGenTestSessionCurrentPktSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Packet size in bytes currently used by the running test."
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 7 }
cienaCesBenchmarkGenTestSessionThroughputTestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkThroughputTestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the throughput test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 8 }
cienaCesBenchmarkGenTestSessionFramelossTestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkFramelossTestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the frameloss test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 9 }
cienaCesBenchmarkGenTestSessionLatencyTestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkLatencyPdvTestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the latency test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 10 }
cienaCesBenchmarkGenTestSessionPdvTestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkLatencyPdvTestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the PDV test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 11 }
cienaCesBenchmarkGenTestSessionRfc2544TestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkRfc2544TestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the RFC2544 test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 12 }
cienaCesBenchmarkGenTestSessionY1564TestState OBJECT-TYPE
SYNTAX CienaCesBenchmarkY1564TestState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the Y1564 test for this hardware session
defined by the test instance id, pcp and color"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 13 }
cienaCesBenchmarkGenTestSessionCurrentRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Traffic rate currently used to generate packets as percent
of the line rate"
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 14 }
cienaCesBenchmarkGenTestSessionSamplesCompleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "When latency and/or pdv is running, this indicates how
many samples have been gathered so far."
::= { cienaCesBenchmarkGenTestSessionAllocationEntry 15 }
--
-- Test Instance Stats Table
--
cienaCesBenchmarkTestInstanceStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkTestInstanceStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of test instance packet statistics entries."
::= { cienaCesBenchmarkModule 14 }
cienaCesBenchmarkTestInstanceStatsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkTestInstanceStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Benchmark test instance packet statistics"
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId }
::= { cienaCesBenchmarkTestInstanceStatsTable 1 }
CienaCesBenchmarkTestInstanceStatsEntry ::= SEQUENCE {
cienaCesBenchmarkTestInstanceStatsRxPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxIpv4Pkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxIpv4UdpPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxIpv6Pkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxIpv6UdpPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxNonIpPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxUnrecognizedPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxDuplicatePkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow TruthValue,
cienaCesBenchmarkTestInstanceStatsRxOOOPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxOOOPktsOverflow TruthValue,
cienaCesBenchmarkTestInstanceStatsRxDiscSeqNumPkts Counter64,
cienaCesBenchmarkTestInstanceStatsRxDiscSeqNumPktsOverflow TruthValue,
cienaCesBenchmarkTestInstanceStatsRxUdpCheckSumPkts Counter64,
cienaCesBenchmarkTestInstanceStatsTxPkts Counter64
}
cienaCesBenchmarkTestInstanceStatsRxPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 1 }
cienaCesBenchmarkTestInstanceStatsRxIpv4Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv4 packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 2 }
cienaCesBenchmarkTestInstanceStatsRxIpv4UdpPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv4 UDP packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 3 }
cienaCesBenchmarkTestInstanceStatsRxIpv6Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv6 packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 4 }
cienaCesBenchmarkTestInstanceStatsRxIpv6UdpPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv6 UDP packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 5 }
cienaCesBenchmarkTestInstanceStatsRxNonIpPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of non-IP packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 6 }
cienaCesBenchmarkTestInstanceStatsRxUnrecognizedPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of unrecognized packets received for
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 7 }
cienaCesBenchmarkTestInstanceStatsRxDuplicatePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets received with a duplicate
this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 8 }
cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When set to true, this indicates that the duplicate
pkt counter has rolled over in hardware and therefore,
cienaCesBenchmarkTestInstanceStatsRxDuplicatePkts might
not be accurate."
::= { cienaCesBenchmarkTestInstanceStatsEntry 9 }
cienaCesBenchmarkTestInstanceStatsRxOOOPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets received with an out of
order sequence number. The sequence number was less
than the expected sequence number for this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 10 }
cienaCesBenchmarkTestInstanceStatsRxOOOPktsOverflow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When set to true, this indicates that the out of order
pkt counter has rolled over in hardware and therefore,
cienaCesBenchmarkTestInstanceStatsRxOOOPkts might
not be accurate."
::= { cienaCesBenchmarkTestInstanceStatsEntry 11 }
cienaCesBenchmarkTestInstanceStatsRxDiscSeqNumPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets received with a sequence number
greater then the expected sequence number for this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 12 }
cienaCesBenchmarkTestInstanceStatsRxDiscSeqNumPktsOverflow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When set to true, this indicates that the discontinuity
in sequence number pkt counter has rolled over in hardware
and therefore, cienaCesBenchmarkTestInstanceStatsRxDiscSeqNumPkts
might not be accurate."
::= { cienaCesBenchmarkTestInstanceStatsEntry 13 }
cienaCesBenchmarkTestInstanceStatsRxUdpCheckSumPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of UDP packets received with a UDP checksum
error."
::= { cienaCesBenchmarkTestInstanceStatsEntry 14 }
cienaCesBenchmarkTestInstanceStatsTxPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets transmitted for this test instance."
::= { cienaCesBenchmarkTestInstanceStatsEntry 15 }
--
-- Benchmark Generator Test Session Throughput Results
--
cienaCesBenchmarkGenTestSessionThroughputResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkGenTestSessionThroughputResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of BENCHMARK generator test session throughput results in Mbps."
::= { cienaCesBenchmarkModule 15 }
cienaCesBenchmarkGenTestSessionThroughputResultsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkGenTestSessionThroughputResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK generator test session throughput results."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkGenTestSessionThroughputResultsPcpIndex,
cienaCesBenchmarkGenTestSessionThroughputResultsColorIndex,
cienaCesBenchmarkGenTestSessionThroughputResultsFrameSizeIndex }
::= { cienaCesBenchmarkGenTestSessionThroughputResultsTable 1 }
CienaCesBenchmarkGenTestSessionThroughputResultsEntry ::= SEQUENCE {
cienaCesBenchmarkGenTestSessionThroughputResultsPcpIndex Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsColorIndex Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsFrameSizeIndex Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsPcp Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkGenTestSessionThroughputResultsFrameSize Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsEmixSequenceId Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsMin CienaCesBenchmarkThroughputResult,
cienaCesBenchmarkGenTestSessionThroughputResultsMax CienaCesBenchmarkThroughputResult,
cienaCesBenchmarkGenTestSessionThroughputResultsAvg CienaCesBenchmarkThroughputResult,
cienaCesBenchmarkGenTestSessionThroughputResultsIterations Integer32,
cienaCesBenchmarkGenTestSessionThroughputResultsKpiResult CienaCesBenchmarkKpiResult
}
cienaCesBenchmarkGenTestSessionThroughputResultsPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index of the PCP value"
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 1 }
cienaCesBenchmarkGenTestSessionThroughputResultsColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Color index."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 2 }
cienaCesBenchmarkGenTestSessionThroughputResultsFrameSizeIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame size index for which those throughput results are
for. When EMIX is used, in which case
cienaCesBenchmarkGenTestSessionThroughputResultsEmixSequenceId is
not NULL, there is only one frame size index for
the given test instance Id, pcp and color. In such a case, the
frame size index will be 0 and frame size will also be 0."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 3 }
cienaCesBenchmarkGenTestSessionThroughputResultsPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCP value of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 4 }
cienaCesBenchmarkGenTestSessionThroughputResultsColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Color of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 5 }
cienaCesBenchmarkGenTestSessionThroughputResultsFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet size in bytes. If 0, then the
cienaCesBenchmarkGenTestSessionThroughputResultsEmixSequenceId
indicates the ID of the EMIX sequence used for the test"
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 6 }
cienaCesBenchmarkGenTestSessionThroughputResultsEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the EMIX sequence that was used for running the
test which produced these results. When 0,
frame size indicates the size of the test frame
associated with these results."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 7 }
cienaCesBenchmarkGenTestSessionThroughputResultsMin OBJECT-TYPE
SYNTAX CienaCesBenchmarkThroughputResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum throughput recorded for the given packet size
in Mbps * 100. The value is multiplied by 100 to be able
to send the results as an integer but should be divided
by 100 when displayed to provide a 2 decimal point accuracy.
A result of 123.45 is sent as 12345."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 8 }
cienaCesBenchmarkGenTestSessionThroughputResultsMax OBJECT-TYPE
SYNTAX CienaCesBenchmarkThroughputResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum throughput recorded for the given packet size
in Mbps * 100. The value is multiplied by 100 to be able
to send the results as an integer but should be divided
by 100 when displayed to provide a 2 decimal point accuracy.
A result of 123.45 is sent as 12345."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 9 }
cienaCesBenchmarkGenTestSessionThroughputResultsAvg OBJECT-TYPE
SYNTAX CienaCesBenchmarkThroughputResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average throughput recorded for the given packet size
in Mbps * 100. The value is multiplied by 100 to be able
to send the results as an integer but should be divided
by 100 when displayed to provide a 2 decimal point accuracy.
A result of 123.45 is sent as 12345."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 10 }
cienaCesBenchmarkGenTestSessionThroughputResultsIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the test has been run for this packet size."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 11 }
cienaCesBenchmarkGenTestSessionThroughputResultsKpiResult OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pass or fail results for the test which is determined
by comparing the max throughput against the selected
KPI test instance's throughput pass criteria. If no KPI test instance
is selected for the given test instance Id, the result will
be 'notApplicable'."
::= { cienaCesBenchmarkGenTestSessionThroughputResultsEntry 12 }
--
-- Benchmark Generator Test Session Frameloss Results
--
cienaCesBenchmarkGenTestSessionFramelossResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkGenTestSessionFramelossResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of BENCHMARK generator test session frameloss results."
::= { cienaCesBenchmarkModule 16 }
cienaCesBenchmarkGenTestSessionFramelossResultsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkGenTestSessionFramelossResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK generator test session frameloss results."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkGenTestSessionFramelossResultsPcpIndex,
cienaCesBenchmarkGenTestSessionFramelossResultsColorIndex,
cienaCesBenchmarkGenTestSessionFramelossResultsFrameSizeIndex,
cienaCesBenchmarkGenTestSessionFramelossResultsRateIndex }
::= { cienaCesBenchmarkGenTestSessionFramelossResultsTable 1 }
CienaCesBenchmarkGenTestSessionFramelossResultsEntry ::= SEQUENCE {
cienaCesBenchmarkGenTestSessionFramelossResultsPcpIndex Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsColorIndex Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsFrameSizeIndex Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsRateIndex Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsPcp Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkGenTestSessionFramelossResultsFrameSize Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsRate Integer32,
cienaCesBenchmarkGenTestSessionFramelossResultsFirst CienaCesBenchmarkFramelossResult,
cienaCesBenchmarkGenTestSessionFramelossResultsSecond CienaCesBenchmarkFramelossResult,
cienaCesBenchmarkGenTestSessionFramelossResultsKpiResult CienaCesBenchmarkKpiResult,
cienaCesBenchmarkGenTestSessionFramelossResultsResult CienaCesBenchmarkFramelossResult
}
cienaCesBenchmarkGenTestSessionFramelossResultsPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCP index."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 1 }
cienaCesBenchmarkGenTestSessionFramelossResultsColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Color index."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 2 }
cienaCesBenchmarkGenTestSessionFramelossResultsFrameSizeIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame size index."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 3 }
cienaCesBenchmarkGenTestSessionFramelossResultsRateIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Rate index."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 4 }
cienaCesBenchmarkGenTestSessionFramelossResultsPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCP value of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 5 }
cienaCesBenchmarkGenTestSessionFramelossResultsColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Color of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 6 }
cienaCesBenchmarkGenTestSessionFramelossResultsFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet size in bytes. If 0, then the
cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId
indicates the ID of the EMIX sequence used for the test"
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 7 }
cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the EMIX sequence that was used for running the
test which produced these results. When 0,
frame size indicates the size of the test frame
associated with these results."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 8 }
cienaCesBenchmarkGenTestSessionFramelossResultsRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rate in percent of line rate."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 9 }
cienaCesBenchmarkGenTestSessionFramelossResultsFirst OBJECT-TYPE
SYNTAX CienaCesBenchmarkFramelossResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of frames lost on first test sequence."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 10 }
cienaCesBenchmarkGenTestSessionFramelossResultsSecond OBJECT-TYPE
SYNTAX CienaCesBenchmarkFramelossResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of frames lost on second test sequence."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 11 }
cienaCesBenchmarkGenTestSessionFramelossResultsKpiResult OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pass or fail results for the test which is determined
by comparing the frameloss result against the selected
KPI test instance's frameloss pass criteria. If no KPI test instance
is selected for the given test instance Id, the result will
be 'notApplicable'."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 12 }
cienaCesBenchmarkGenTestSessionFramelossResultsResult OBJECT-TYPE
SYNTAX CienaCesBenchmarkFramelossResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of frames lost on the largest test sequence results."
::= { cienaCesBenchmarkGenTestSessionFramelossResultsEntry 13 }
--
-- Benchmark Generator Test Session Latency Results
--
cienaCesBenchmarkGenTestSessionLatencyResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkGenTestSessionLatencyResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of BENCHMARK generator test session latency results in usec."
::= { cienaCesBenchmarkModule 17 }
cienaCesBenchmarkGenTestSessionLatencyResultsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkGenTestSessionLatencyResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK generator test session latency results."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkGenTestSessionLatencyResultsPcpIndex,
cienaCesBenchmarkGenTestSessionLatencyResultsColorIndex,
cienaCesBenchmarkGenTestSessionLatencyResultsFrameSizeIndex }
::= { cienaCesBenchmarkGenTestSessionLatencyResultsTable 1 }
CienaCesBenchmarkGenTestSessionLatencyResultsEntry ::= SEQUENCE {
cienaCesBenchmarkGenTestSessionLatencyResultsPcpIndex Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsColorIndex Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsFrameSizeIndex Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsPcp Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkGenTestSessionLatencyResultsFrameSize Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsEmixSequenceId Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsMin Unsigned32,
cienaCesBenchmarkGenTestSessionLatencyResultsMax Unsigned32,
cienaCesBenchmarkGenTestSessionLatencyResultsAvg Unsigned32,
cienaCesBenchmarkGenTestSessionLatencyResultsSamples Integer32,
cienaCesBenchmarkGenTestSessionLatencyResultsKpiResult CienaCesBenchmarkKpiResult
}
cienaCesBenchmarkGenTestSessionLatencyResultsPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCP index."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 1 }
cienaCesBenchmarkGenTestSessionLatencyResultsColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Color index."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 2 }
cienaCesBenchmarkGenTestSessionLatencyResultsFrameSizeIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame size index."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 3 }
cienaCesBenchmarkGenTestSessionLatencyResultsPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCP value of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 4 }
cienaCesBenchmarkGenTestSessionLatencyResultsColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Color of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 5 }
cienaCesBenchmarkGenTestSessionLatencyResultsFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet size in bytes."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 6 }
cienaCesBenchmarkGenTestSessionLatencyResultsEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the EMIX sequence that was used for running the
test which produced these results. When 0,
frame size indicates the size of the test frame
associated with these results."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 7 }
cienaCesBenchmarkGenTestSessionLatencyResultsMin OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum latency recorded for the given packet size."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 8 }
cienaCesBenchmarkGenTestSessionLatencyResultsMax OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum latency recorded for the given packet size."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 9 }
cienaCesBenchmarkGenTestSessionLatencyResultsAvg OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average latency recorded for the given packet size."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 10 }
cienaCesBenchmarkGenTestSessionLatencyResultsSamples OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of samples taken during the test."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 11 }
cienaCesBenchmarkGenTestSessionLatencyResultsKpiResult OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pass or fail results for the test which is determined
by comparing the frameloss result against the selected
KPI test instance's latency pass criteria. If no KPI test instance
is selected for the given test instance Id, the result will
be 'notApplicable'."
::= { cienaCesBenchmarkGenTestSessionLatencyResultsEntry 12 }
--
-- Benchmark Test Session Packet Delay Variation Results
--
cienaCesBenchmarkGenTestSessionPdvResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkGenTestSessionPdvResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of BENCHMARK generator test session packet delay
variation results in usec."
::= { cienaCesBenchmarkModule 18 }
cienaCesBenchmarkGenTestSessionPdvResultsEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkGenTestSessionPdvResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK generator test session packet delay variation results."
INDEX { cienaCesBenchmarkEntityEntryId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkGenTestSessionPdvResultsPcpIndex,
cienaCesBenchmarkGenTestSessionPdvResultsColorIndex,
cienaCesBenchmarkGenTestSessionPdvResultsFrameSizeIndex }
::= { cienaCesBenchmarkGenTestSessionPdvResultsTable 1 }
CienaCesBenchmarkGenTestSessionPdvResultsEntry ::= SEQUENCE {
cienaCesBenchmarkGenTestSessionPdvResultsPcpIndex Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsColorIndex Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsFrameSizeIndex Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsPcp Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsColor CienaCesBenchmarkColorTest,
cienaCesBenchmarkGenTestSessionPdvResultsFrameSize Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsEmixSequenceId Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsAvg Unsigned32,
cienaCesBenchmarkGenTestSessionPdvResultsSamples Integer32,
cienaCesBenchmarkGenTestSessionPdvResultsKpiResult CienaCesBenchmarkKpiResult
}
cienaCesBenchmarkGenTestSessionPdvResultsPcpIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCP index."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 1 }
cienaCesBenchmarkGenTestSessionPdvResultsColorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Color index."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 2 }
cienaCesBenchmarkGenTestSessionPdvResultsFrameSizeIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame size index associated to those PDV stats."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 3 }
cienaCesBenchmarkGenTestSessionPdvResultsPcp OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCP value of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 4 }
cienaCesBenchmarkGenTestSessionPdvResultsColor OBJECT-TYPE
SYNTAX CienaCesBenchmarkColorTest
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Color of the test packets associated with those
results."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 5 }
cienaCesBenchmarkGenTestSessionPdvResultsFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet size in bytes."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 6 }
cienaCesBenchmarkGenTestSessionPdvResultsEmixSequenceId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the EMIX sequence that was used for running the
test which produced these results. When 0,
frame size indicates the size of the test frame
associated with these results."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 7 }
cienaCesBenchmarkGenTestSessionPdvResultsAvg OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average PDV recorded for the given packet size."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 8 }
cienaCesBenchmarkGenTestSessionPdvResultsSamples OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of samples used for the test."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 9 }
cienaCesBenchmarkGenTestSessionPdvResultsKpiResult OBJECT-TYPE
SYNTAX CienaCesBenchmarkKpiResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pass or fail results for the test which is determined
by comparing the frameloss result against the selected
KPI test instance's throughput PDV criteria. If no KPI test instance
is selected for the given test instance Id, the result will
be 'notApplicable'."
::= { cienaCesBenchmarkGenTestSessionPdvResultsEntry 10 }
--
-- Benchmark EMIX character set table
--
cienaCesBenchmarkEmixCharacterSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesBenchmarkEmixCharacterSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of BENCHMARK EMIX character set providing the
list of characters that can be used in an EMIX sequence
along with their corresponding frame size."
::= { cienaCesBenchmarkModule 19 }
cienaCesBenchmarkEmixCharacterSetEntry OBJECT-TYPE
SYNTAX CienaCesBenchmarkEmixCharacterSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BENCHMARK EMIX character and its associated frame size."
INDEX { cienaCesBenchmarkEmixCharacterSetEntryIndex }
::= { cienaCesBenchmarkEmixCharacterSetTable 1 }
CienaCesBenchmarkEmixCharacterSetEntry ::= SEQUENCE {
cienaCesBenchmarkEmixCharacterSetEntryIndex Integer32,
cienaCesBenchmarkEmixCharacterSetEntryCharacter DisplayString,
cienaCesBenchmarkEmixCharacterSetEntryFrameSize DisplayString
}
cienaCesBenchmarkEmixCharacterSetEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..26)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Character index."
::= { cienaCesBenchmarkEmixCharacterSetEntry 1 }
cienaCesBenchmarkEmixCharacterSetEntryCharacter OBJECT-TYPE
SYNTAX DisplayString (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"EMIX character that can be used for creating an EMIX sequence.
The character set currently includes: a b c d e f g h u v w x "
::= { cienaCesBenchmarkEmixCharacterSetEntry 2 }
cienaCesBenchmarkEmixCharacterSetEntryFrameSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame size associated with the character. For h, the frame size
is the port under test's MTU and the u character is a custom
frame size configurable for each EMIX. The u frame size can take
a value of 64 to 10000 and defaults to 594. If u is bigger than
the MTU of the port under test, it will be reduced to the same
size as h."
::= { cienaCesBenchmarkEmixCharacterSetEntry 3 }
--
-- Trap definitions
--
cienaCesBenchmarkTestStarted NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkEntityEntryPortId,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkTestInstanceEntrySvid,
cienaCesBenchmarkTestInstanceEntryCvid,
cienaCesBenchmarkTestInstanceEntryDstMac
}
STATUS current
DESCRIPTION
"The start command has been issued for the given benchmark generator
test instance, either via CLI or SNMP. The cienaCesBenchmarkEntityEntryPortId
specifies the port under test when the test instance was started;
the s-vid, c-vid and destination mac address used to build the test
packet are also provided."
::= { cienaCesBenchmarkNotifications 1 }
cienaCesBenchmarkTestStopped NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName
}
STATUS current
DESCRIPTION
"The specified generator test instance has been manually stopped by
the user, either via CLI or SNMP, before the testing completed."
::= { cienaCesBenchmarkNotifications 2 }
cienaCesBenchmarkTestCompleted NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName
}
STATUS current
DESCRIPTION
"The testing for the specified generator test instance has finished the
configured number of iterations as configured in the referenced
profile interval and duration."
::= { cienaCesBenchmarkNotifications 3 }
cienaCesBenchmarkTestFailedThroughputKpi NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkKpiProfileId,
cienaCesBenchmarkKpiPcp,
cienaCesBenchmarkKpiColor,
cienaCesBenchmarkGenTestSessionCurrentPktSize,
cienaCesBenchmarkEmixSequenceId,
cienaCesBenchmarkGenTestSessionThroughputResultsMax
}
STATUS current
DESCRIPTION
"The throughput test result for the specified generator test
instance is below the specified throughput KPI value for
the given PCP and color traffic."
::= { cienaCesBenchmarkNotifications 4 }
cienaCesBenchmarkTestFailedFramelossKpi NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkKpiProfileId,
cienaCesBenchmarkKpiPcp,
cienaCesBenchmarkKpiColor,
cienaCesBenchmarkGenTestSessionCurrentPktSize,
cienaCesBenchmarkEmixSequenceId,
cienaCesBenchmarkGenTestSessionFramelossResultsResult
}
STATUS current
DESCRIPTION
"The frameloss test result for the specified generator test
instance exceeds the specified throughput KPI value for
the given PCP and color traffic."
::= { cienaCesBenchmarkNotifications 5 }
cienaCesBenchmarkTestFailedLatencyKpi NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkKpiProfileId,
cienaCesBenchmarkKpiPcp,
cienaCesBenchmarkKpiColor,
cienaCesBenchmarkGenTestSessionCurrentPktSize,
cienaCesBenchmarkEmixSequenceId,
cienaCesBenchmarkGenTestSessionLatencyResultsMax
}
STATUS current
DESCRIPTION
"The latency test result for the specified generator test
instance exceeds the specified throughput KPI value for
the given PCP and color traffic."
::= { cienaCesBenchmarkNotifications 6 }
cienaCesBenchmarkTestFailedPdvKpi NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkKpiProfileId,
cienaCesBenchmarkKpiPcp,
cienaCesBenchmarkKpiColor,
cienaCesBenchmarkGenTestSessionCurrentPktSize,
cienaCesBenchmarkEmixSequenceId,
cienaCesBenchmarkGenTestSessionPdvResultsAvg
}
STATUS current
DESCRIPTION
"The throughput test result for the specified generator test
instance is below the specified throughput KPI value for
the given PCP and color traffic."
::= { cienaCesBenchmarkNotifications 7 }
cienaCesBenchmarkTestIterationCompleted NOTIFICATION-TYPE
OBJECTS { cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesBenchmarkTestInstanceEntryId,
cienaCesBenchmarkTestInstanceEntryName,
cienaCesBenchmarkGenTestSessionThroughputResultsIterations
}
STATUS current
DESCRIPTION
"An iteration of tests for the given test instance has just completed."
::= { cienaCesBenchmarkNotifications 8 }
END