-- CERENT-ENVMON-MIB module
--
-- This module contains the environmental monitoring objects and
-- events for the Cisco ONS devices.
-- Copyright (c) 2004 by Cisco Systems, Inc.
-- All rights reserved.
--
-- **************************************************************
CERENT-ENVMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
cerentModules,
cerentRequirements,
cerentGeneric
FROM CERENT-GLOBAL-REGISTRY
DisplayString
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
MODULE-IDENTITY,
OBJECT-IDENTITY,
OBJECT-TYPE,
Gauge32,
Integer32
FROM SNMPv2-SMI;
cerentEnvMonMIB MODULE-IDENTITY
LAST-UPDATED "200401271451Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Support@Cisco.com
Postal: 1435 North McDowell Blvd
Petaluma CA 94954
Tel: +1.877.323.7368"
DESCRIPTION
"This MIB module provides Environmental status information"
REVISION "200401271451Z"
DESCRIPTION
"First Version"
::= { cerentModules 120 }
cerentEnvMonMibConformance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This node is created for compliance. Has
objects as required by the RFCs"
::= { cerentRequirements 70 }
cerentEnvMonMibCompliance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The compliance statements
for Cisco ONS devices."
::= { cerentEnvMonMibConformance 10 }
cerentEnvMonMibGroups OBJECT-IDENTITY
STATUS current
DESCRIPTION
"All the objects and events are
grouped under this for conformance"
::= { cerentEnvMonMibConformance 20 }
cerentEnvMonObjects OBJECT-IDENTITY
STATUS current
DESCRIPTION
""
::= { cerentGeneric 80 }
cerentEnvMonVoltageStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentEnvMonVoltageStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maintains the status info for all
EnvMon related voltages picked up by the
sensors in the device."
::= { cerentEnvMonObjects 10 }
cerentEnvMonVoltageStatsEntry OBJECT-TYPE
SYNTAX CerentEnvMonVoltageStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There will as many rows as there are sensors
in the device."
INDEX {
cerentEnvMonVoltageStatsIndex }
::= { cerentEnvMonVoltageStatsTable 1 }
CerentEnvMonVoltageStatsEntry ::= SEQUENCE {
cerentEnvMonVoltageStatsIndex Integer32,
cerentEnvMonVoltageStatsDescr DisplayString,
cerentEnvMonVoltageStatsCurrentValue Integer32,
cerentEnvMonVoltageStatsThresholdVeryHigh Integer32,
cerentEnvMonVoltageStatsThresholdHigh Integer32,
cerentEnvMonVoltageStatsThresholdLow Integer32,
cerentEnvMonVoltageStatsThresholdVeryLow Integer32 }
cerentEnvMonVoltageStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value index uniquely indicates the voltage
sensor in the device. "
::= { cerentEnvMonVoltageStatsEntry 10 }
cerentEnvMonVoltageStatsDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Name/Description of the voltage
sensor."
::= { cerentEnvMonVoltageStatsEntry 20 }
cerentEnvMonVoltageStatsCurrentValue OBJECT-TYPE
SYNTAX Integer32
UNITS
"millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current voltage measurement at this
voltage sensor."
::= { cerentEnvMonVoltageStatsEntry 30 }
cerentEnvMonVoltageStatsThresholdVeryHigh OBJECT-TYPE
SYNTAX Integer32
UNITS
"millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the current voltage value exceeds this
threshold value, an alarm event will be raised
by the device.
The severity of this event may be
provisionable."
::= { cerentEnvMonVoltageStatsEntry 40 }
cerentEnvMonVoltageStatsThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS
"millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the current voltage value exceeds this
threshold value, a warning event will be raised
by the device.
The severity of this event may be
provisionable."
::= { cerentEnvMonVoltageStatsEntry 50 }
cerentEnvMonVoltageStatsThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS
"millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the current voltage value falls below this
threshold value, a warning event will be raised
by the device.
The severity of this event may be
provisionable."
::= { cerentEnvMonVoltageStatsEntry 60 }
cerentEnvMonVoltageStatsThresholdVeryLow OBJECT-TYPE
SYNTAX Integer32
UNITS
"millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the current voltage value falls below this
threshold value, an alarm event will be raised
by the device.
The severity of this event may be
provisionable."
::= { cerentEnvMonVoltageStatsEntry 70 }
cerentEnvMonTemperatureStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentEnvMonTemperatureStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides ambient temperature
information as measured by the
temperature sensors."
::= { cerentEnvMonObjects 20 }
cerentEnvMonTemperatureStatsEntry OBJECT-TYPE
SYNTAX CerentEnvMonTemperatureStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each temperature is represented by a row
in the table."
INDEX {
cerentEnvMonTemperatureStatsIndex }
::= { cerentEnvMonTemperatureStatsTable 1 }
CerentEnvMonTemperatureStatsEntry ::= SEQUENCE {
cerentEnvMonTemperatureStatsIndex Integer32,
cerentEnvMonTemperatureStatsDescr DisplayString,
cerentEnvMonTemperatureStatsCurrentValue Gauge32,
cerentEnvMonTemperatureStatsThresholdHigh Gauge32 }
cerentEnvMonTemperatureStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value index uniquely indicates the
temperature sensor in the device. "
::= { cerentEnvMonTemperatureStatsEntry 10 }
cerentEnvMonTemperatureStatsDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Name/Description of the
temperature sensor."
::= { cerentEnvMonTemperatureStatsEntry 20 }
cerentEnvMonTemperatureStatsCurrentValue OBJECT-TYPE
SYNTAX Gauge32
UNITS
"Degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Temperature measurement at this
temperature sensor."
::= { cerentEnvMonTemperatureStatsEntry 30 }
cerentEnvMonTemperatureStatsThresholdHigh OBJECT-TYPE
SYNTAX Gauge32
UNITS
"Degree Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the current temperature value exceeds this
threshold value, an alarm event will be
raised by the device.
The severity of this event may be
provisionable."
::= { cerentEnvMonTemperatureStatsEntry 40 }
cerentEnvMonMibObjectsGroup OBJECT-GROUP
OBJECTS {
cerentEnvMonVoltageStatsDescr,
cerentEnvMonVoltageStatsCurrentValue,
cerentEnvMonVoltageStatsThresholdVeryHigh,
cerentEnvMonVoltageStatsThresholdHigh,
cerentEnvMonVoltageStatsThresholdLow,
cerentEnvMonVoltageStatsThresholdVeryLow,
cerentEnvMonTemperatureStatsDescr,
cerentEnvMonTemperatureStatsCurrentValue,
cerentEnvMonTemperatureStatsThresholdHigh
}
STATUS current
DESCRIPTION
"All NMS accessible objects"
::= { cerentEnvMonMibGroups 10 }
cerentEnvMonMibBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The basic implementation requirements
for all Cisco ONS network devices."
MODULE
MANDATORY-GROUPS { cerentEnvMonMibObjectsGroup }
::= { cerentEnvMonMibCompliance 10 }
END