mibs/MIBS/cisco/CERENT-GENERIC-PM-MIB

561 lines
20 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- **************************************************************
-- CERENT-GENERIC-PM-MIB module
--
-- October 2004, Srikar B S
-- This module contains the objects for Thresholds and performance
-- monitoring for Electrical and Optical Cards on the
-- Cisco ONS devices
-- Copyright (c) 2004-2005 by Cisco Systems, Inc.
-- All rights reserved.
--
-- **************************************************************
-- This MIB complementes the CERENT-HC-RMON-MIB and contains the threshold
-- table and permforamance monitoring statistics tables for
-- Optical/Electrical modules
CERENT-GENERIC-PM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Counter64
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
cerentModules,
cerentGeneric,
cerentRequirements
FROM CERENT-GLOBAL-REGISTRY
CerentAlarmThresholdMonitorType,
CerentMonitorType,
CerentLocation,
CerentPeriod
FROM CERENT-TC;
cerentGenericPmMIB MODULE-IDENTITY
LAST-UPDATED "200410130000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" support@Cisco.com
Postal: Cisco Systems
1450 N. McDowell Blvd.
Petaluma, CA 94954
USA
Tel: +1-877-323-7368"
DESCRIPTION
"This module defines
objects for managing generic thresholds and
performance monitoring information"
REVISION "200410130000Z"
DESCRIPTION
"Inital version of the module"
::= { cerentModules 130 }
cerentGenericPmMIBObjects OBJECT IDENTIFIER
::= { cerentGeneric 90 }
-- All Cisco ONS 15454 Threshold definitions.
cerentGenericPmThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentGenericPmThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per performance monitoring
threshold."
::= { cerentGenericPmMIBObjects 10 }
cerentGenericPmThresholdEntry OBJECT-TYPE
SYNTAX CerentGenericPmThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerentGenericPmThresholdTable"
INDEX {
cerentGenericPmThresholdIndex,
cerentGenericPmThresholdMonitorType,
cerentGenericPmThresholdLocation,
cerentGenericPmThresholdPeriod
}
::= { cerentGenericPmThresholdTable 1 }
CerentGenericPmThresholdEntry ::= SEQUENCE {
cerentGenericPmThresholdIndex Integer32,
cerentGenericPmThresholdMonitorType CerentMonitorType,
cerentGenericPmThresholdLocation CerentLocation,
cerentGenericPmThresholdPeriod CerentPeriod,
cerentGenericPmThresholdValue Integer32,
cerentGenericPmThresholdOverFlowValue Integer32,
cerentGenericPmThresholdHCValue Counter64
}
cerentGenericPmThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in Threshold table.
May not start with one and there will be some
missing numbers."
::= { cerentGenericPmThresholdEntry 10 }
cerentGenericPmThresholdMonitorType OBJECT-TYPE
SYNTAX CerentMonitorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the type of metric monitored."
::= { cerentGenericPmThresholdEntry 20 }
cerentGenericPmThresholdLocation OBJECT-TYPE
SYNTAX CerentLocation
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates if the threshold value represented by this row
is for near or far end"
::= { cerentGenericPmThresholdEntry 30 }
cerentGenericPmThresholdPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sampling interval period is indicated here"
::= { cerentGenericPmThresholdEntry 40 }
cerentGenericPmThresholdValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lower word value of the threshold that was
provisioned by the NMS"
::= { cerentGenericPmThresholdEntry 50 }
cerentGenericPmThresholdOverFlowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The higher word value of the threshold that was
provisioned by the NMS"
::= { cerentGenericPmThresholdEntry 60 }
cerentGenericPmThresholdHCValue OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object will be the 64 bit threshold that was
provisioned by the NMS"
::= { cerentGenericPmThresholdEntry 70 }
cerentGenericPmStatsCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentGenericPmStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds all the performance Monitoring
statistics for current sampling period."
::= { cerentGenericPmMIBObjects 20 }
cerentGenericPmStatsCurrentEntry OBJECT-TYPE
SYNTAX CerentGenericPmStatsCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerentGenericPmStatsCurrentTable"
INDEX {
cerentGenericPmStatsCurrentIndex,
cerentGenericPmStatsCurrentType,
cerentGenericPmStatsCurrentLocation,
cerentGenericPmStatsCurrentPeriod
}
::= { cerentGenericPmStatsCurrentTable 1 }
CerentGenericPmStatsCurrentEntry ::= SEQUENCE {
cerentGenericPmStatsCurrentIndex Integer32,
cerentGenericPmStatsCurrentType CerentMonitorType,
cerentGenericPmStatsCurrentLocation CerentLocation,
cerentGenericPmStatsCurrentPeriod CerentPeriod,
cerentGenericPmStatsCurrentValue Integer32,
cerentGenericPmStatsCurrentOverFlowValue Integer32,
cerentGenericPmStatsCurrentHCValue Counter64,
cerentGenericPmStatsCurrentValidData TruthValue,
cerentGenericPmStatsCurrentValidIntervals Integer32
}
cerentGenericPmStatsCurrentIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in performance monitor table.
May not start with one and there will be some
missing numbers."
::= { cerentGenericPmStatsCurrentEntry 10 }
cerentGenericPmStatsCurrentType OBJECT-TYPE
SYNTAX CerentMonitorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the type of metric monitored."
::= { cerentGenericPmStatsCurrentEntry 20 }
cerentGenericPmStatsCurrentLocation OBJECT-TYPE
SYNTAX CerentLocation
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates if the threshold value represented by this row
is for near or far end"
::= { cerentGenericPmStatsCurrentEntry 30 }
cerentGenericPmStatsCurrentPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sampling interval period is indicated here"
::= { cerentGenericPmStatsCurrentEntry 40 }
cerentGenericPmStatsCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with this monitor type for this
entity in the in the current interval of duration
defined by cerentGenericPmStatsPeriod"
::= { cerentGenericPmStatsCurrentEntry 50 }
cerentGenericPmStatsCurrentOverFlowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter holds the higher ordered value associated with
this monitor type for this
entity in the in the current interval of duration
defined by cerentGenericPmStatsPeriod"
::= { cerentGenericPmStatsCurrentEntry 60 }
cerentGenericPmStatsCurrentHCValue OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 64 bit counter associated with this monitor type for this
entity in the in the current interval of duration
defined by cerentGenericPmStatsCurrentPeriod"
::= { cerentGenericPmStatsCurrentEntry 70 }
cerentGenericPmStatsCurrentValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates if the data for the current sampling period
is valid"
::= { cerentGenericPmStatsCurrentEntry 80 }
cerentGenericPmStatsCurrentValidIntervals OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects specifies the number of contiguous intervals
for which the valid values are available for this performance
monitoring type."
::= { cerentGenericPmStatsCurrentEntry 90 }
cerentGenericPmStatsIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentGenericPmStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds all the performance Monitoring
statistics for completed intervals"
::= { cerentGenericPmMIBObjects 30 }
cerentGenericPmStatsIntervalEntry OBJECT-TYPE
SYNTAX CerentGenericPmStatsIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerentGenericPmStatsIntervalTable"
INDEX {
cerentGenericPmStatsIntervalIndex,
cerentGenericPmStatsIntervalType,
cerentGenericPmStatsIntervalLocation,
cerentGenericPmStatsIntervalPeriod,
cerentGenericPmStatsIntervalNumber
}
::= { cerentGenericPmStatsIntervalTable 1 }
CerentGenericPmStatsIntervalEntry ::= SEQUENCE {
cerentGenericPmStatsIntervalIndex Integer32,
cerentGenericPmStatsIntervalType CerentMonitorType,
cerentGenericPmStatsIntervalLocation CerentLocation,
cerentGenericPmStatsIntervalPeriod CerentPeriod,
cerentGenericPmStatsIntervalNumber Integer32,
cerentGenericPmStatsIntervalValue Integer32,
cerentGenericPmStatsIntervalOverFlowValue Integer32,
cerentGenericPmStatsIntervalHCValue Counter64,
cerentGenericPmStatsIntervalValidData TruthValue
}
cerentGenericPmStatsIntervalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in performance monitor table.
May not start with one and there will be some
missing numbers."
::= { cerentGenericPmStatsIntervalEntry 10 }
cerentGenericPmStatsIntervalType OBJECT-TYPE
SYNTAX CerentMonitorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the type of metric monitored."
::= { cerentGenericPmStatsIntervalEntry 20 }
cerentGenericPmStatsIntervalLocation OBJECT-TYPE
SYNTAX CerentLocation
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates if the threshold value represented by this row
is for near or far end"
::= { cerentGenericPmStatsIntervalEntry 30 }
cerentGenericPmStatsIntervalPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sampling interval period is indicated here"
::= { cerentGenericPmStatsIntervalEntry 40 }
cerentGenericPmStatsIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval
for which the statistics is available.
The interval identified by 1 is the most recently completed interval
and the interval identified by N is the interval immediately
preceding the one identified by N-1."
::= { cerentGenericPmStatsIntervalEntry 50 }
cerentGenericPmStatsIntervalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with this monitor type for this
entity in the in a particular interval of duration
defined by cerentGenericPmStatsIntervalPeriod"
::= { cerentGenericPmStatsIntervalEntry 60 }
cerentGenericPmStatsIntervalOverFlowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The higher order 32 bit value of the counter associated with this
monitor type for this
entity in the in a particular interval of duration
defined by cerentGenericPmStatsIntervalNumber"
::= { cerentGenericPmStatsIntervalEntry 70 }
cerentGenericPmStatsIntervalHCValue OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 64-bit counter associated with this monitor type for this
entity in the in a particular interval of duration
defined by cerentGenericPmStatsIntervalPeriod"
::= { cerentGenericPmStatsIntervalEntry 80 }
cerentGenericPmStatsIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates if the data for this interval is valid"
::= { cerentGenericPmStatsIntervalEntry 90 }
-- All Cisco ONS 15454 AlarmThreshold Definitions
cerentGenericPmAlarmThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentGenericPmAlarmThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per performance monitoring
AlarmThreshold."
::= { cerentGenericPmMIBObjects 40 }
CerentGenericPmAlarmThresholdEntry ::= SEQUENCE {
cerentGenericPmAlarmThresholdIndex Integer32,
cerentGenericPmAlarmThresholdMonitorType CerentAlarmThresholdMonitorType,
cerentGenericPmAlarmThresholdValue Integer32,
cerentGenericPmAlarmThresholdOverFlowValue Integer32,
cerentGenericPmAlarmThresholdHCValue Counter64
}
cerentGenericPmAlarmThresholdEntry OBJECT-TYPE
SYNTAX CerentGenericPmAlarmThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerentGenericPmAlarmThresoldTable"
INDEX {
cerentGenericPmAlarmThresholdIndex,
cerentGenericPmAlarmThresholdMonitorType
}
::= { cerentGenericPmAlarmThresholdTable 1 }
cerentGenericPmAlarmThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in AlarmThreshold table.
May not start with one and there will be some
missing numbers."
::= { cerentGenericPmAlarmThresholdEntry 10 }
cerentGenericPmAlarmThresholdMonitorType OBJECT-TYPE
SYNTAX CerentAlarmThresholdMonitorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the type of metric monitored."
::= { cerentGenericPmAlarmThresholdEntry 20 }
cerentGenericPmAlarmThresholdValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lower word value of the AlarmThreshold that was
provisioned by the NMS"
::= { cerentGenericPmAlarmThresholdEntry 30 }
cerentGenericPmAlarmThresholdOverFlowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The higher word value of the AlarmThreshold that was
provisioned by the NMS"
::= { cerentGenericPmAlarmThresholdEntry 40 }
cerentGenericPmAlarmThresholdHCValue OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object will be the 64 bit AlarmThreshold that was
provisioned by the NMS"
::= { cerentGenericPmAlarmThresholdEntry 50 }
cerentGenericPmMIBConformance OBJECT IDENTIFIER
::= { cerentRequirements 80 }
cerentGenericPmMIBCompliances OBJECT IDENTIFIER
::= { cerentGenericPmMIBConformance 1}
cerentGenericPmMIBGroups OBJECT IDENTIFIER
::= { cerentGenericPmMIBConformance 2}
cerentGenericPmMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the
High Capacity Media Independent Group."
MODULE -- this module
MANDATORY-GROUPS { cerentGenericPmThresholdGroup,
cerentGenericPmStatsCurrentGroup,
cerentGenericPmStatsIntervalGroup }
::= { cerentGenericPmMIBCompliances 1 }
-- This group covers for threshold display and TCA trap
cerentGenericPmThresholdGroup OBJECT-GROUP
OBJECTS {
cerentGenericPmThresholdValue,
cerentGenericPmThresholdOverFlowValue,
cerentGenericPmThresholdHCValue
}
STATUS current
DESCRIPTION
"The objects for storing all the current alarm thresholds "
::= { cerentGenericPmMIBGroups 10 }
-- This group covers Performance Monitoring in current interval
cerentGenericPmStatsCurrentGroup OBJECT-GROUP
OBJECTS {
cerentGenericPmStatsCurrentValue,
cerentGenericPmStatsCurrentOverFlowValue,
cerentGenericPmStatsCurrentHCValue,
cerentGenericPmStatsCurrentValidData,
cerentGenericPmStatsCurrentValidIntervals
}
STATUS current
DESCRIPTION
"The objects for storing all the performance montitoring statistics"
::= { cerentGenericPmMIBGroups 20 }
-- This group covers Performance Monitoring in current interval
cerentGenericPmStatsIntervalGroup OBJECT-GROUP
OBJECTS {
cerentGenericPmStatsIntervalValue,
cerentGenericPmStatsIntervalOverFlowValue,
cerentGenericPmStatsIntervalHCValue,
cerentGenericPmStatsIntervalValidData
}
STATUS current
DESCRIPTION
"The objects for storing all the performance montitoring statistics"
::= { cerentGenericPmMIBGroups 30 }
--This group covers for Alarm displays and traps
cerentGenericPmAlarmThresholdGroup OBJECT-GROUP
OBJECTS {
cerentGenericPmAlarmThresholdValue,
cerentGenericPmAlarmThresholdOverFlowValue,
cerentGenericPmAlarmThresholdHCValue
}
STATUS current
DESCRIPTION
"The objects for storing all the current alarm thresholds "
::= { cerentGenericPmMIBGroups 40 }
END