-- CERENT-IF-EXT-MIB module
--
-- December 2005, Srikar B S
-- This module is an extension of the IF-MIB.
-- Copyright (c) 2005-2006 by Cisco Systems, Inc.
-- All rights reserved.
--
-- **************************************************************
-- This MIB is an extension of the IF-MIB and contains objects
-- to manage interfaces.
CERENT-IF-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
ifIndex FROM IF-MIB
cerentModules,
cerentGeneric,
cerentRequirements
FROM CERENT-GLOBAL-REGISTRY;
cerentIfExtMIB MODULE-IDENTITY
LAST-UPDATED "200511140000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" support@Cisco.com
Postal: Cisco Systems
1450 N. McDowell Blvd.
Petaluma, CA 94954
USA
Tel: +1-877-323-7368"
DESCRIPTION
"This module defines objects for managing interfaces."
REVISION "200511140000Z"
DESCRIPTION
"Inital version of the module"
::= { cerentModules 140 }
cerentIfExtMIBObjects OBJECT IDENTIFIER
::= { cerentGeneric 100 }
cerentIfExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF CerentIfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per interface."
::= { cerentIfExtMIBObjects 10 }
cerentIfExtEntry OBJECT-TYPE
SYNTAX CerentIfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerentIfExtTable"
INDEX { ifIndex }
::= { cerentIfExtTable 1 }
CerentIfExtEntry ::= SEQUENCE {
cerentIfExtPreServiceAlarmSuppression TruthValue,
cerentIfExtConfiguredSoakTime Integer32,
cerentIfExtCurrentSoakTime Integer32
}
cerentIfExtPreServiceAlarmSuppression OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object can be set through a management interface.
When the administrative state of this interface is 'down',
the value of this object does not have any impact.
When the administrative state of this interface is 'up',
if this object has a value of 'false', an alarm on this
interface will be reported. If the value of this object is 'true'
then all alarms on this interface will be suppressed.
If the interface has a good signal, the soak timer will be
started, if the port is faulted before the soak timer expires,
the soak timer will be reset to the provisioned maximum value.
If the soak timer expires then the value of this object is
automatically set to 'false'."
DEFVAL { false }
::= { cerentIfExtEntry 10 }
cerentIfExtConfiguredSoakTime OBJECT-TYPE
SYNTAX Integer32
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the configured maximum value of the soak timer
for this interface."
DEFVAL { 480 }
::= { cerentIfExtEntry 20 }
cerentIfExtCurrentSoakTime OBJECT-TYPE
SYNTAX Integer32
UNITS "minutes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the current value of the soak timer
for this interface. The difference between
cerntIfExtConfiguredSoakTime and this object gives the
time duration for which this interface has had a good signal."
::= { cerentIfExtEntry 30 }
cerentIfExtMIBConformance OBJECT IDENTIFIER
::= { cerentRequirements 90 }
cerentIfExtMIBCompliances OBJECT IDENTIFIER
::= { cerentIfExtMIBConformance 1}
cerentIfExtMIBGroups OBJECT IDENTIFIER
::= { cerentIfExtMIBConformance 2}
cerentIfExtMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the
High Capacity Media Independent Group."
MODULE -- this module
MANDATORY-GROUPS { cerentIfExtGroup }
::= { cerentIfExtMIBCompliances 1 }
cerentIfExtGroup OBJECT-GROUP
OBJECTS {
cerentIfExtPreServiceAlarmSuppression,
cerentIfExtConfiguredSoakTime,
cerentIfExtCurrentSoakTime
}
STATUS current
DESCRIPTION
"The objects for storing all the current alarm thresholds "
::= { cerentIfExtMIBGroups 10 }