mibs/MIBS/cisco/CISCO-VISM-DSX0-MIB

1701 lines
61 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ****************************************************************
-- ciscoVismDsx0MIB
-- The MIB for DS0 interface configuration and
-- Alarm Configuration for VISM(Voice Interface Module)
-- in MGX products.
--
-- March 2004, Rashmi Purandare
--
-- Copyright (c) 2003,2004 by Cisco Systems, Inc.
-- All rights reserved.
-- ****************************************************************
CISCO-VISM-DSX0-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
DisplayString,
TruthValue FROM SNMPv2-TC
dsx0Vism,
cardSpecific FROM BASIS-MIB
ciscoWan FROM CISCOWAN-SMI;
ciscoVismDsx0MIB MODULE-IDENTITY
LAST-UPDATED "200403110000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-wanatm@cisco.com"
DESCRIPTION
"This MIB module contains ds0 configuration,
Status and DS0 related information on a
DS1 interface supported in VISM module.
VISM is a Voice Interworking Service Module supported
in MGX8250 and MGX8850 and other MGX products.
Terminologies used:
line : Same as the Physical Interface.
DS1 line signifies DS1 interface."
REVISION "200403110000Z"
DESCRIPTION
"Added
- ds0Companding
- ds0RxCasTransTblName
- ds0TxCasTransTblName
- ds0TxRxCasConfig
- ciscoVismDsx0Compliance2
- ciscoVismDsx0ConfGroup2
Deprecated
- ciscoVismDsx0Compliance
- ciscoVismDsx0ConfGroup
"
REVISION "200308030000Z"
DESCRIPTION
"Added following tables:
dsx0VismCnfTable
dsx0VismChanMapTable
These tables were defined in CISCO-WAN-AXIPOP-MIB
(an unrelated mib) earlier. The relevant contents
from CISCO-WAN-AXIPOP-MIB are moved and converted
to SMIv2 and defined here."
REVISION "200306170000Z"
DESCRIPTION
"Initial version of the MIB.
The content of this MIB was originally available
in SMIv1 version. The MIB has been converted to
SMIv2 version and descriptions of some of the objects
have been modified."
::= { ciscoWan 81 }
vismDs0CardStats OBJECT IDENTIFIER ::= { cardSpecific 24 }
-- -----------------------------------------------------------------
--
-- dsx0Vism group:
--
-- This group contains the tables/objects necessary to configure
-- the DS0s on DS1/E1 interfaces of VISM.
-- -----------------------------------------------------------------
dsx0VismCnfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx0VismCnfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries in this table are created and deleted
implicitly at the time of adding and deleting the line.
For every DS0 on a line, one row will be created."
::= { dsx0Vism 1 }
dsx0VismCnfEntry OBJECT-TYPE
SYNTAX Dsx0VismCnfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This ds0 table contains both cas related
and non cas related parameters.
The non cas related parameters are applicable
accross all line signaling types, while the
following cas related parameters
are applicable only if the signaling type
of the line(DS1/E1 Interface) to which this ds0 belongs
is cas.
ds0IdleCode
ds0SeizedCode
ds0ReceivedCode
ds0CasVariantName
ds0CasCadenceOnTime
ds0CasCadenceOffTime
ds0InsertLocalCas
ds0LocalCasPattern
ds0CasParameterSource
ds0CasOnHookMinMakeTime
ds0CasOffHookMinMakeTime
ds0CasWinkMinMakeTime
ds0CasWinkMaxMakeTime
ds0CasWinkBreakTime
ds0CasGlareTime
ds0CasGaurdTime
ds0CasDelayImmedStart
ds0CasMinDelayDialTime
ds0CasMinStartDialTime
ds0CasFlashMinMakeTime
ds0CasFlashMaxMakeTime
ds0CasDirectionality
ds0CasGlarePolicy
ds0CasIncomingMgcpPackage
ds0CasOutgoingMgcpPackage
When the line signaling type changes from cas to non-cas
and vice versa, then the user will be forced to delete
endpoint/ccs channels associated with any ds0 on that line
When an endpoint is deleted the ds0CasVariantName associated
with that endpoint will also be implicitly deleted.
Other than that none of the above cas related parameters are
modified across line signaling type changes."
INDEX { ds0IfIndex }
::= { dsx0VismCnfTable 1 }
Dsx0VismCnfEntry ::=
SEQUENCE {
ds0IfIndex Integer32,
ds0RobbedBitSignalling TruthValue,
ds0IdleCode Integer32,
ds0SeizedCode Integer32,
ds0ReceivedCode Integer32,
ds0TransmitCodesEnable TruthValue,
ds0BundleMapped Integer32,
ds0IfType INTEGER,
ds0CasVariantName DisplayString,
ds0CasCadenceOnTime Integer32,
ds0CasCadenceOffTime Integer32,
ds0InsertLocalCas TruthValue,
ds0LocalCasPattern Integer32,
ds0LoopbackCommand INTEGER,
ds0CasParameterSource INTEGER,
ds0CasOnHookMinMakeTime Integer32,
ds0CasOffHookMinMakeTime Integer32,
ds0CasWinkMinMakeTime Integer32,
ds0CasWinkMaxMakeTime Integer32,
ds0CasWinkBreakTime Integer32,
ds0CasGlareTime Integer32,
ds0CasGaurdTime Integer32,
ds0CasDelayImmedStart Integer32,
ds0SignalingType INTEGER,
ds0CasMinDelayDialTime Integer32,
ds0CasMinStartDialTime Integer32,
ds0CasFlashMinMakeTime Integer32,
ds0CasFlashMaxMakeTime Integer32,
ds0CasDirectionality INTEGER,
ds0CasGlarePolicy INTEGER,
ds0CasIncomingMgcpPackage DisplayString,
ds0CasOutgoingMgcpPackage DisplayString,
ds0InputGain Integer32,
ds0OutputAttenuation Integer32,
ds0MusicThreshold Integer32,
ds0SidPacket TruthValue,
ds0ExecDiag TruthValue,
ds0Companding INTEGER,
ds0RxCasTransTblName DisplayString,
ds0TxCasTransTblName DisplayString,
ds0TxRxCasConfig INTEGER
}
ds0IfIndex OBJECT-TYPE
SYNTAX Integer32 (1..248)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute defines the index for this table.
This is derived from the following formula:
index = 31 * (Ds1# - 1) + ds0#
where : Ds1# - The T1/E1 line number in the range 1 - 8.
ds0# - The ds0 channel number ranging from
1 to 24 for T1
and 1 to 31 for E1."
::= {dsx0VismCnfEntry 1}
ds0RobbedBitSignalling OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Robbed Bit Signalling is
turned on or off for a given ds0. This only
applies to DS0s on a DS1 link. For E1 links the
value is always off (false). For T1 links, the default
value is true if the line is configured for CAS signaling,
the default value is false if the line is configured for
CCS signaling or no signaling."
::= { dsx0VismCnfEntry 2 }
ds0IdleCode OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the code transmitted in the
ABCD bits when the ds0 is not connected and
ds0TransmitCodesEnable is enabled. The object is
a bitmap and the various bit positions are:
Bit 0 (value 1) D bit
Bit 1 (value 2) C bit
Bit 2 (value 4) B bit
Bit 3 (value 8) A bit
This object is useful for ds0 conditioning to be
done if an alarm condition is detected from the
network side. DS0 conditioning is implemented in
the trunking application only.
This object is not applicable in the CAS backhaul
application.
From vism 2.0.3 release onwards this object can
be configured in any mode, but will be applicable
only in trunking application and will be ignored
in other applications."
DEFVAL { 0 }
::= { dsx0VismCnfEntry 3 }
ds0SeizedCode OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the code transmitted in the
ABCD bits when the ds0 is connected and
ds0TransmitCodesEnable is enabled. The object is
a bitmap and the various bit positions are:
Bit 0 (value 1) D bit
Bit 1 (value 2) C bit
Bit 2 (value 4) B bit
Bit 3 (value 8) A bit
This object is useful for ds0 conditioning to be
done if an alarm condition is detected from the
network side. DS0 conditioning is implemented in
the trunking application only.
This object is not applicable in the CAS backhaul
application.
From vism 2.0.3 release onwards this object can
be configured in any mode, but will be applicable
only in trunking application and will be ignored
in other applications."
DEFVAL { 15 }
::= { dsx0VismCnfEntry 4 }
ds0ReceivedCode OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the code being received in
the ABCD bits. The object is a bitmap and the
various bit positions are:
Bit 0 (value 1) D bit
Bit 1 (value 2) C bit
Bit 2 (value 4) B bit
Bit 3 (value 8) A bit"
::= { dsx0VismCnfEntry 5 }
ds0TransmitCodesEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object determines if the idle and seized
codes are transmitted. If the value of this object
is true then the codes are transmitted.
This object is not applicable in the CAS backhaul
application."
DEFVAL { true }
::= { dsx0VismCnfEntry 6 }
ds0BundleMapped OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates endpoint number as specified
by mgEndpointNumber of endpoint table.
If it is not associated with any endpoint, then it
is set to -1.
It should be noted that the endpoint is associated
with bearer DS0s only. For signaling channel or DS0
as in the case of CCS channel, there is no endpoint
number associated with it and the value is set to -1."
::= { dsx0VismCnfEntry 7 }
ds0IfType OBJECT-TYPE
SYNTAX INTEGER {
bearer (81),
ccs-signaling (63),
unknown (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the interface type associated
with the ds0.
bearer(81) : ds0 ifType is considered as bearer if
the DS0 is used for carrying voice traffic.
ccs-signaling(63): ds0 ifType is considered as ccs-signaling,
if the DS0 is configured as the D-channel."
::= { dsx0VismCnfEntry 8 }
ds0CasVariantName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the index to the CAS variant
table. This parameter can be configured after configuring
this ds0 as an endpoint. This object cannot be modified
while connections exist on this endpoint. The CAS variant
table is used for configuring the system parameters associated
with various types of CAS signaling methods supported."
::= { dsx0VismCnfEntry 9 }
ds0CasCadenceOnTime OBJECT-TYPE
SYNTAX Integer32(2..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute describes the duration during which the digit
tone is generated.
This object is applicable only for CAS backhaul applications.
For trunking application it is not applicable.
The value is expresssed in units of milliseconds.
From vism2.0.3 release onwards this object can
configured in any application, but will be applicable
only in non-trunking applications and will be ignored
in other applications."
DEFVAL {75}
::= {dsx0VismCnfEntry 10 }
ds0CasCadenceOffTime OBJECT-TYPE
SYNTAX Integer32(0..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute corresponds to the silence between the
digit tones.
This object is applicable only for CAS backhaul applications.
For trunking application it is not applicable.
The value is expresssed in units of milliseconds.
From vism2.0.3 release onwards this object can
configured in any application, but will be applicable
only in non-trunking applications and will be ignored
in other applications."
DEFVAL {75}
::= {dsx0VismCnfEntry 11}
ds0InsertLocalCas OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object tells the framer whether to force the cas bits
to a value defined by ds0LocalCasPattern or not.
If this is enabled the framer will force the cas (ABCD) bits
to a value defined in ds0LocalCasPattern by ignorning the
cas bits sent by DSP. Else the framer will transmit the cas
bits sent by DSP.
Setting of this object is not allowed when the signaling type
of this line is cas.
Also setting of this object is not allowed when the
ds0LoopbackCommand is set to RemoteLoop, because in this
situation we are suppose to loopback whatever comes from
the TDM side and not force the cas bits to something else.
This object can be set only if the line type is T1."
DEFVAL {false}
::= {dsx0VismCnfEntry 12}
ds0LocalCasPattern OBJECT-TYPE
SYNTAX Integer32(0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the pattern that the cas (ABCD) bits will have
when ds0InsertLocalCas is enabled."
DEFVAL{0}
::={dsx0VismCnfEntry 13}
ds0LoopbackCommand OBJECT-TYPE
SYNTAX INTEGER {
noLoop (1),
remoteLoop (2),
localLoop (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the loopback type at the ds0 level.The
ds0 configuration overrides the line level configuration.
NoLoop
There is no loopback on this ds0.
LocalLoop
The data received from the ATM side is loopedback
to the ATM side.
RemoteLoop
The data from the TDM side is looped back to the
TDM side.
Setting of this object to RemoteLoop will not be allowed when
insert local cas for this ds0 (ds0InsertLocalCas object) is
enabled as we are suppose to force the cas bits to the pattern
configured in ds0LocalCasPattern, and not do loopback on the
TDM side."
DEFVAL{noLoop}
::= {dsx0VismCnfEntry 14}
ds0CasParameterSource OBJECT-TYPE
SYNTAX INTEGER
{
casAppl (1),
mibValue (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates VISM whether to read the cas related
timer parameters from the casAppl file downloaded for that
endpoint or to read from this mib.
This gives the flexibility of configuring
different cas related timer values for different
endpoints associated with the same cas variant.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint."
DEFVAL{casAppl}
::= { dsx0VismCnfEntry 15 }
ds0CasOnHookMinMakeTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the the minimum time in msecs
for which the on hook pattern should be present in order for it
to be recognised else the signal will be considered to be a
spurious signal and will be ignored.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint.
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000"
DEFVAL {300}
::= { dsx0VismCnfEntry 16 }
ds0CasOffHookMinMakeTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the minimum time in msecs for
which the off hook pattern should be present in order for it to be
recognised else the signal will be considered to be a spurious signal
and will be ignored.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000"
DEFVAL {20}
::= { dsx0VismCnfEntry 17 }
ds0CasWinkMinMakeTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wink consists of off-hook A-B bit pattern, followed
by on-hook A-B bit pattern in timed sequence.
This object indicates the minimum duration for which
the off-hook part of wink signal should persist.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000."
DEFVAL {100}
::= { dsx0VismCnfEntry 18 }
ds0CasWinkMaxMakeTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "millisesconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wink consists of off-hook A-B bit pattern, followed
by on-hook A-B bit pattern in timed sequence.
This object indicates the maximum duration for which the
off-hook part of the wink signal should persist, if it
exceeds this time limit the signal will be considered to
be spurious and will be ignored.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..3000.
The value for this object should be greater than or equal to
ds0CasWinkMinMakeTime"
DEFVAL {350}
::= { dsx0VismCnfEntry 19 }
ds0CasWinkBreakTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wink consists of off-hook A-B bit pattern,
followed by on-hook A-B bit pattern in timed sequence.
This object indicates the minimum duration for which
the on-hook part of wink signal should persist.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000."
DEFVAL {70}
::= { dsx0VismCnfEntry 20 }
ds0CasGlareTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the terminating gateway receives off Hook event
from the Call Agent it starts the timer specified in
this object to see if the terminating side is also
trying to originate a call. If this is true, we have
a 'glare' condition. The way glare is resolved is
thru this user programmable timer, we will not honor
any off hook events from the originating PBX during
this time.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non CAS.
For a CAS line this object can only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..10000."
DEFVAL {100}
::= { dsx0VismCnfEntry 21 }
ds0CasGaurdTime OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gaurd time is the duration between the end of one call
and the start of next call. This object specifies what should
be such a duration. All state changes from the PBX are ignored
for this duration. After receiving DLCX, this timer will be
started for a period as configured in this object, and will
not honor any off-hook events before the expiration of this timer.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000."
DEFVAL {800}
::= { dsx0VismCnfEntry 22 }
ds0CasDelayImmedStart OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This timer indicates the time that VISM should wait before
outpulsing digits to the PBX after sending an off hook event.
This applies only to immediate start protocol.
This object cannot be configured if the signaling
type for the line to which this ds0 belongs is non cas.
For a cas line this object CAN only be configured
only after associating this ds0 with an endpoint.
This object will be applicable if ds0CasParameterSource
has a value of mibValue (2).
The allowed range for this object is 10..1000."
DEFVAL {500}
::= { dsx0VismCnfEntry 23 }
ds0SignalingType OBJECT-TYPE
SYNTAX INTEGER {
cas (1),
ccs (2),
none (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of signaling on the line
to which this ds0 belongs.
CAS - Channel Associated Signaling
CCS - Common Channel Signaling
none - no signaling used.
This object will be implicitly set to line signaling
type every time it changes."
DEFVAL { none }
::= {dsx0VismCnfEntry 24}
ds0CasMinDelayDialTime OBJECT-TYPE
SYNTAX Integer32
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an object for an E & M signaling protocol like
wink-start for this ds0. The difference is that the
address-control signal is different from wink.
The originating VISM, on receiving a seize (AB=11) from the
PBX, responds by sending the delay-dial (AB=11) signal back
to the PBX. When the originating VISM is ready to collect
the digits, it sends a start-dial (AB=00) signal.
This operation is symmetric. So the terminating VISM, on
seizing a trunk, should receive AB=11
(as an ack that the trunk is operational). Subsequently,
when it receives the start signal (AB=00) from the connected PBX,
it should outpulse the digits. The rest of the operation
is similiar to wink-start.
The allowed range for this object is 100..1000 with
units in milliseconds.
In delay-dial operation, the outgoing interface (this interface),
after sending a seize signal (AB = 11), waits for the delay-dial
signal (AB = 11). The delay-dial signal, apart from
acknowledging the seize signal, tells this interface that
the connected equipment is not ready for the digits yet.
This object specifies the time in milliseconds, after which
incoming AB=11 will be interpreted by this interface as the
delay-dial signal."
REFERENCE
"1. Generic Requirements, GR-506-CORE, Issue 1, June 1996,
Revision 1, November 1996,
2. LSSGR: Signaling for Analog Interfaces
Section 11.2.3 is about 'Delay-Dial Operation' (in general)
In particular, section 11.2.3.1 ([R11-21] is about these
timing requirements."
DEFVAL {100}
::= {dsx0VismCnfEntry 25}
ds0CasMinStartDialTime OBJECT-TYPE
SYNTAX Integer32
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an object for an E & M signaling protocol like
wink-start for this ds0. The difference is that the
address-control signal is different from wink. The originating
VISM, on receiving a seize (AB=11) from the PBX,
responds by sending the delay-dial (AB=11) signal back
to the PBX. When the originating VISM is ready to collect
the digits, it sends a start-dial (AB=00) signal.
This operation is symmetric. So the terminating VISM, on
seizing a trunk, should receive AB=11
(as an ack that the trunk is operational). Subsequently,
when it receives the start signal (AB=00) from
the connected PBX, it should outpulse the digits.
The rest of the operation is similiar to wink-start.
The allowed range for this object is 70..1000.
In delay-dial operation, the outgoing interface (this interface),
after receiving a delay-dial signal (AB=11) from the connected
equipment, waits for the start-dial signal (AB = 00) before
sending the digits to the connected equipment.
The start-dial signal tells this interface that the
connected equipment is ready for the digits.
This object specifies the time in milliseconds, after which
incoming AB=00 will be interpreted by this interface as the
start dial signal."
REFERENCE
"1. Generic Requirements, GR-506-CORE, Issue 1, June 1996,
Revision 1, November 1996,
2. LSSGR: Signaling for Analog Interfaces
Section 11.2.3 is about 'Delay-Dial Operation' (in general)
In particular, section 11.2.3.1 ([R11-22] and [R11-23]) is
about these timing requirements."
DEFVAL {70}
::= {dsx0VismCnfEntry 26}
ds0CasFlashMinMakeTime OBJECT-TYPE
SYNTAX Integer32
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flash is a CAS signal generated by users to request
special services. The interpretation of the flash
depends on the protocol in use. The signal itself
is an on-hook followed by an off-hook. This object
specifies the minimum duration for the signal to be
recognized as a flash by VISM. This duration,
expressed in milliseconds, is defined as the elapsed
time between the off-to-on-hook transition followed by
the on-to-off-hook transition.
If the on-hook duration is shorter than the value of
this object, the signal will be ignored.
This object cannot be configured if the signaling type
for the line to which this ds0 belongs is non-CAS.
For a CAS line, this object can only be configured
after associating this ds0 with an endpoint.
If no endpoint was added for this Ds0, any configuration
attempt will be rejected.
This object will be applicable if ds0CasParameterSource
has a value of mibvalue (2).
The allowed range for this object is 50..1550."
DEFVAL {300}
::= {dsx0VismCnfEntry 27}
ds0CasFlashMaxMakeTime OBJECT-TYPE
SYNTAX Integer32
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flash is a CAS signal generated by users to request
special services. The interpretation of the flash
depends on the protocol in use. The signal itself is
an on-hook followed by an off-hook. This object specifies
the maximum duration for the signal to be recognized as a
flash by VISM. This duration, expressed in milliseconds,
is defined as the elapsed time between the off-to-on-hook
transition followed by the on-to-off-hook transition.
If the on-hook duration is longer than the value of this object,
the signal will be ignored.
This object cannot be configured if the signaling type
for the line to which this ds0 belongs is non-CAS.
For a CAS line, this object can only be configured after
associating this ds0 with an endpoint. This means that
if no endpoint was added for this Ds0, any configuration
set attempt will be rejected, but any get will be allowed.
This object will be applicable if ds0CasParameterSource
has a value of 'mibvalue'(2).
The allowed range for this object is 50..1550.
The value of this object should be greater than
or equal to ds0CasFlashMinMakeTime."
DEFVAL {1400}
::= {dsx0VismCnfEntry 28}
ds0CasDirectionality OBJECT-TYPE
SYNTAX INTEGER {
bidirectional (1),
incoming (2),
outgoing (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the direction in which CAS calls
will be accepted on this endpoint. If this object is set to
bidirectional(1): VISM can send and receive calls on this
endpoint
incoming(2) : calls from the connected PBX will be
accepted by VISM on this endpoint.
outgoing(3) : VISM will send calls towards the connected PBX and
not accept calls from the PBX.
The main difference between bidirectional and one-way trunks
is the occurrence of glare. On bidirectional trunks, since both
VISM and the connected PBX can seize the endpoint at
approximately the same time, glare (dual seizure) is likely to occur.
The protocol assigned to a bidirectional endpoint should be
capable of detecting and resolving glare.
Wink-start and delay-dial are examples of protocols capable of
glare handling and immediate-start, ground-start and loop-start,
of those that cannot.
This object cannot be configured if the signaling type for
the DS1 line to which this ds0 belongs is non-CAS.
For a CAS line, this object can only be configured after
associating this ds0 with an endpoint. This means that if
no endpoint was added for this Ds0, any configuration set
attempt will be rejected, but any get will be allowed."
DEFVAL {bidirectional}
::= {dsx0VismCnfEntry 29}
ds0CasGlarePolicy OBJECT-TYPE
SYNTAX INTEGER {
controlling (1),
releasing (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies how a bidirectional endpoint should
resolve glare. This object will be used only if
dsx0VismDirectionality of the endpoint is 'bidirectional'.
When glare is detected, if this object is set to controlling,
VISM will wait for the connected PBX to assert on-hook.
When the connected PBX goes on-hook, VISM proceeds to dial
the numbers out waits for answer.
If this object is set to releasing(2), VISM indicates the
glare situation to the Call Agent
(as specified by the control protocol), prepares to collect
digits from the PBX and asserts on hook. The incoming call
should go through.
If the CAS protocol assigned to the endpoint cannot detect
glare or if it cannot resolve glare according to the policy
provisioned via this object, this object will not be used.
This object cannot be configured if the signaling type
for the DS1 line to which this ds0 belongs is non-CAS.
For a CAS line, this object can only be configured after
associating this ds0 with an endpoint. This means that if no
endpoint was added for this Ds0, any configuration set
attempt will be rejected, but any get will be allowed."
DEFVAL {controlling}
::= {dsx0VismCnfEntry 30}
ds0CasIncomingMgcpPackage OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, in conjunction with the card level
persistentXgcpEventsTable, controls how persistent
CAS events (like seize, disconnect, etc) related
to an incoming call observed on this DS0 are notified to
the Media Gateway Controller (MGC).
At the card level, the persistentXgcpEventsTable allows
MGCP package-event combinations to be configured as persistent.
For example, when L/hd is added to the persistentXgcpEventsTable,
the hook-down event in line package will be notified to the MGC
every time it is observed without the MGC requesting for that event.
Since the same CAS event can map to different MGCP events under
different packages (eg. the CAS event 'seize' can be 'sup' in
'MS' package and 'hd' in 'BL' package) and different lines could
be running different packages at a given time, there needs to be
a per-DS0 object indicating what package should be used while
notifying CAS events observed on that DS0. This object,
ds0CasIncomingMgcpPackage specifies the package that will be
used while notifying CAS events observed on an incoming call
on this DS0.
This object can be set to a package name from
xgcpCapabilityPackageTable whose
xgcpCapabilityPackageEnable is true or the string 'basic'
indicating that one of the basic packages in that table
(G, T, L, H, R, D or M) to which the observed event belongs
can be used.
This object is used only if the protocol is MGCP.
If the notification is in response to an RQNT, VISM
uses the package (and event name) that the MGC used
to request the event regardless what this object is set to.
In the absence of an RQNT, the observed CAS event is
encoded according to the package that this object specifies.
A 'seize' observed on the CAS signaling channel on this DS0,
for example is encoded as 'ms/sup' if this object is
set to 'ms', 'bl/hd' if this object is set to 'bl' or
as 'L/hd' if this object is set to 'basic'.
If this package/event is present in persistentXgcpEventsTable,
a notification is generated, otherwise this event is discarded.
An attempt to set this object to a package name whose
xgcpCapabilityPackageEnable is false in
xgcpCapabilityPackageTable will fail.
This object is used only if the ds0CasDirectionality is set
to 'bidirectional' or 'incoming'."
::= {dsx0VismCnfEntry 31}
ds0CasOutgoingMgcpPackage OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, in conjunction with the card level
persistentXgcpEventsTable, controls how persistent
CAS events (like answer, disconnect, etc) related
to an outgoing call observed on this DS0 are notified to the
Media Gateway Controller (MGC).
At the card level, the persistentXgcpEventsTable allows
MGCP package-event combinations to be configured as persistent.
For example, when L/hd is added to the persistentXgcpEventsTable,
the hook-down event in line package will be notified to the MGC
every time it is observed without the MGC requesting for that event.
Since the same CAS event can map to different MGCP events
under different packages (eg. the CAS event 'answer' can be
'ans' in 'MS' package and 'hd' in 'BL' package) and different
lines could be running different packages at a given time,
there needs to be a per-DS0 object indicating what package
should be used while notifying CAS events observed on that DS0.
This object, ds0CasOutgoingMgcpPackage specifies the package
that will be used while notifying CAS events observed on an
outgoing call on this DS0.
This object can be set to a package name from
xgcpCapabilityPackageTable whose xgcpCapabilityPackageEnable
is true or the string 'basic' indicating that one
of the basic packages in that table (G, T, L, H, R, D or M)
to which the observed event belongs can be used.
This object is used only if the protocol is MGCP.
If the notification is in response to an RQNT,
VISM uses the package (and event name) that the MGC used
to request the event regardless what this object is set to.
In the absence of an RQNT, the observed CAS event is encoded
according to the package that this object specifies.
An answer observed on the CAS signaling channel on this DS0,
for example is encoded as 'ms/ans' if this object is set to 'ms',
'bl/hd' if this object is set to 'bl' or as 'L/hd' if this object is
set to 'basic'. If this package/event is present in
persistentXgcpEventsTable, a notification is generated,
otherwise this event is discarded.
An attempt to set this object to a package name whose
xgcpCapabilityPackageEnable is false in
xgcpCapabilityPackageTable will fail.
This object is used only if the ds0CasDirectionality is set
to 'bidirectional' or 'outgoing'."
::= {dsx0VismCnfEntry 32}
ds0InputGain OBJECT-TYPE
SYNTAX Integer32 (-6..14)
UNITS "dB - decibel"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the amount of gain inserted at the
receiver side of a ds0 channel, in dB (decibel) units.
The default value of this object is 0 dB.
The input gain settings only define a gain/loss relative
to the 0 dB setting. The absolute loss at the 0 dB setting
could be implementation dependent based on the desired network
loss plan.
This object can be set when there are active call going on,
and in this case the new gain will take effective immediately.
It can also be set at both unbound endpoints and bound but
non-active endpoints."
DEFVAL { 0 }
::= {dsx0VismCnfEntry 33}
ds0OutputAttenuation OBJECT-TYPE
SYNTAX Integer32 (0..14)
UNITS "dB - decibel"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the amount of attenuation inserted
at the transmit side of a ds0 channel, in dB (decibel) units.
The output attenuation settings only define a loss relative to
0 dB setting. The absolute loss at the 0 dB setting could be
implementation dependent based on the desired network loss plan.
This object can be set when there are active call going on,
and in this case the new gain will take effective immediately.
It can also be set at both unbound endpoints and bound but
non-active endpoints.
"
DEFVAL { 0 }
::= {dsx0VismCnfEntry 34}
ds0MusicThreshold OBJECT-TYPE
SYNTAX Integer32 (-70..-30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The indicates Music On Hold Threshold in dBm. Based on this
value, VISM DSP will interprete the incoming signal from TDM side
as either silence or voice, and consequently turn on or off VAD.
This object can be set when there is active call going on at the
ds0 channel, and at both unbound endpoints and bound non-active
endpoints.
"
DEFVAL { -38 }
::= {dsx0VismCnfEntry 35}
ds0SidPacket OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies whether the Silence Indication
Detection (SID) packet should be generated when silence
suppression is in active mode. The SID packet indicates
the noise level during silence, which is used as a reference
to generate comfort noise on the other side of the gateway.
This object is used for VoIP only."
DEFVAL {true}
::= {dsx0VismCnfEntry 36}
ds0ExecDiag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the status of DSP channel level
RAS on the VISM. When it is enable VISM will configure
the DSP through HOST-DSP message on the individual channel."
DEFVAL{true}
::= { dsx0VismCnfEntry 37 }
ds0Companding OBJECT-TYPE
SYNTAX INTEGER
{
uLaw (1),
aLaw (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether input from / output
to the TDM side of DS0 is u-law or a-law stream.
The setting of this object will not take effect
unless the corresponding DSP channel is closed and
re-opened."
::= { dsx0VismCnfEntry 38 }
ds0RxCasTransTblName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the template name 'cvcmCasTemplateName'
in the CISCO-VOICE-CAS-MODULE-MIB associated with the receive
signaling channel on a DS0."
::= { dsx0VismCnfEntry 39 }
ds0TxCasTransTblName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the template name
'cvcmCasTemplateName' in the CISCO-VOICE-CAS-MODULE-MIB
associated with the transmit signaling channel
on a DS0."
::= { dsx0VismCnfEntry 40 }
ds0TxRxCasConfig OBJECT-TYPE
SYNTAX INTEGER {
transmit (1),
receive (2),
bidirectional (3),
none (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates configuration on a DS0.
'transmit'- Configure transmit signaling channel
on the DSP with user defined CAS
pattern to translate incoming ABCD
CAS bits from the TDM
'receive'- Configure receive signaling channel
on the DSP with user defined CAS
pattern to translate the outgoing
ABCD CAS bits on the TDM
'bidirectional'- Configure transmit and receive
signaling channel on the DSP with
user defined CAS pattern to translate
incoming and outgoing ABCD CAS bits
on the TDM
'none'- Signaling channel is using default
ABCD CAS pattern specified by the DSP."
::= { dsx0VismCnfEntry 41 }
-------------------------------------------------------------------
--
-- dsx0VismChanMapTable
-- This table defines the mapping between the Ds0 and the ifIndex
-- used to index the table dsx0VismCnfTable.
-------------------------------------------------------------------
dsx0VismChanMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx0VismChanMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is created implicitly at the time of
creating and deleting the endpoints.
This table provides the mapping information from a line
and channel to obtain an index for that channel."
::= { dsx0Vism 2 }
dsx0VismChanMapEntry OBJECT-TYPE
SYNTAX Dsx0VismChanMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry represents the mapping from dsx1Line number
to ds0 channel Number and provides the ifIndex mapping."
INDEX { dsx1LineNum, ds0ChanNum }
::= { dsx0VismChanMapTable 1 }
Dsx0VismChanMapEntry ::=
SEQUENCE {
dsx1LineNum Integer32,
ds0ChanNum Integer32,
ds0ChanMapIfIndex Integer32
}
dsx1LineNum OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the physical line number on
VISM card."
::= { dsx0VismChanMapEntry 1 }
ds0ChanNum OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the ds0 number or channel number
within a T1 or E1 line.
The valid channel numbers are 1 to 24 for T1 line
and 1 - 31 for E1 line."
::= { dsx0VismChanMapEntry 2 }
ds0ChanMapIfIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the ifIndex derived based on the
line number and the channel number within the line according
to the formula:
IfIndex = 31 * (Ds1# - 1) + ds0#
where : Ds1# - The T1/E1 line number in the range 1 - 8.
ds0# - The ds0 channel number ranging from
1 to 24 for T1
and 1 to 31 for E1."
::= { dsx0VismChanMapEntry 3 }
vismTotalDs0Count OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the total number of ds0s configured the card."
DEFVAL { 0 }
::= { vismDs0CardStats 1 }
vismFreeDs0Count OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of free ds0s on the card."
DEFVAL { 0 }
::= { vismDs0CardStats 2 }
vismActiveDs0Count OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of active ds0s on the card."
::= { vismDs0CardStats 3 }
vismBlockDs0Count OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of blocked ds0s on the card."
DEFVAL { 0 }
::= { vismDs0CardStats 4 }
vismActiveHighWaterMark OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the high water mark number of ds0s that were
active simultaneously on the card."
DEFVAL { 0 }
::= { vismDs0CardStats 5 }
vismDs0CardStatsClrButton OBJECT-TYPE
SYNTAX INTEGER {
noaction (1),
clear (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to clear all the vism Ds0
card stats. 1 = No action, 2 = Clear alarm"
::= { vismDs0CardStats 6 }
--
-- VISM DS0 Line Stats table
--
vismDs0LineStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF VismDs0LineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on DS0s configured
on DS1 interface."
::= { dsx0Vism 3 }
vismDs0LineStatsEntry OBJECT-TYPE
SYNTAX VismDs0LineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the vismDs0LineStatsTable.
Each entry contains following information
applicable for each DS1 interface:
Total DS0s
Free DS0s
Active DS0s
Blocked DS0s."
INDEX { ds0LineNum }
::= { vismDs0LineStatsTable 1 }
VismDs0LineStatsEntry ::=
SEQUENCE {
ds0LineNum Integer32,
lineTotalDs0Count Integer32,
lineFreeDs0Count Integer32,
lineActiveDs0Count Integer32,
lineBlockDs0Count Integer32,
lineActiveHighWaterMark Integer32,
lineStatsClrButton INTEGER
}
ds0LineNum OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the identifier of a DS1/E1 Interface on
a managed device. The number of entries is 8 in a VISM
and VISM-PR card."
::= { vismDs0LineStatsEntry 1 }
lineTotalDs0Count OBJECT-TYPE
SYNTAX Integer32(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the total number of ds0s configured on this
DS1 line."
DEFVAL { 0 }
::= { vismDs0LineStatsEntry 2 }
lineFreeDs0Count OBJECT-TYPE
SYNTAX Integer32(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the total number of free ds0s on this
DS1 line."
DEFVAL { 0 }
::= { vismDs0LineStatsEntry 3 }
lineActiveDs0Count OBJECT-TYPE
SYNTAX Integer32(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of active ds0s on this line."
DEFVAL { 0 }
::= { vismDs0LineStatsEntry 4 }
lineBlockDs0Count OBJECT-TYPE
SYNTAX Integer32(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of blocked ds0s on this line."
DEFVAL { 0 }
::= { vismDs0LineStatsEntry 5 }
lineActiveHighWaterMark OBJECT-TYPE
SYNTAX Integer32(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the high water mark number of ds0s that
were active simultaneously on the line."
DEFVAL { 0 }
::= { vismDs0LineStatsEntry 6 }
lineStatsClrButton OBJECT-TYPE
SYNTAX INTEGER {
noaction (1),
clear (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to clear the vism Ds0 line
status entry. 1 = No action, 2 = Clear alarm."
::= { vismDs0LineStatsEntry 7 }
--
-- VISM DS0 Status table
--
vismDs0StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF VismDs0StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ds0 status information on a
DS1 interface."
::= { dsx0Vism 4 }
vismDs0StatusEntry OBJECT-TYPE
SYNTAX VismDs0StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ds0 Status Table."
INDEX { ds0LineNumber, ds0Number }
::= { vismDs0StatusTable 1 }
VismDs0StatusEntry ::=
SEQUENCE {
ds0LineNumber Integer32,
ds0Number Integer32,
ds0Status INTEGER,
ds0StatusClrButton INTEGER
}
ds0LineNumber OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the identifier of a DS1/E1 Interface
on a managed device. The number of entries is 8 in a
VISM and VISM-PR card."
::= { vismDs0StatusEntry 1 }
ds0Number OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the ds0 number on a
DS1 interface."
::= { vismDs0StatusEntry 2 }
ds0Status OBJECT-TYPE
SYNTAX INTEGER {
idle (1),
busy (2),
fault (3),
block (4),
unknown (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the status of the ds0. idle - This ds0
is in idle state. busy - This ds0 is in busy state.
Ds0 enters this state when it is in the process of
being setup for a call. fault - This ds0 is in fault(alarm)
state. block - This ds0 is in block state.
Ds0 can enter this state when the line or
gateway is commissioned out of service."
DEFVAL { unknown }
::= { vismDs0StatusEntry 3 }
ds0StatusClrButton OBJECT-TYPE
SYNTAX INTEGER {
noaction (1),
clear (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to clear the vism Ds0
status. 1 = No action, 2 = Clear alarm"
::= { vismDs0StatusEntry 4 }
-- conformance information
ciscoVismDsx0MIBConformance OBJECT IDENTIFIER ::= { ciscoVismDsx0MIB 2 }
ciscoVismDsx0MIBGroups OBJECT IDENTIFIER ::=
{ ciscoVismDsx0MIBConformance 1 }
ciscoVismDsx0MIBCompliances OBJECT IDENTIFIER ::=
{ ciscoVismDsx0MIBConformance 2 }
-- compliance statements
ciscoVismDsx0Compliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for objects related
to DS0 mib objects."
MODULE -- this module
MANDATORY-GROUPS {
ciscoVismDsx0LineStatsGroup,
ciscoVismDsx0StatusGroup,
ciscoVismDsx0ConfGroup,
ciscoVismDsx0ChanMapGroup,
ciscoVismCardStatsGroup
}
::= { ciscoVismDsx0MIBCompliances 1 }
ciscoVismDsx0Compliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for objects related
to DS0 mib objects."
MODULE -- this module
MANDATORY-GROUPS {
ciscoVismDsx0LineStatsGroup,
ciscoVismDsx0StatusGroup,
ciscoVismDsx0ConfGroup2,
ciscoVismDsx0ChanMapGroup,
ciscoVismCardStatsGroup
}
::= { ciscoVismDsx0MIBCompliances 2 }
ciscoVismCardStatsGroup OBJECT-GROUP
OBJECTS {
vismTotalDs0Count,
vismFreeDs0Count,
vismActiveDs0Count,
vismBlockDs0Count,
vismActiveHighWaterMark,
vismDs0CardStatsClrButton
}
STATUS current
DESCRIPTION
"The collection of objects used for
DS0 Statistics applicable to VISM Module."
::= { ciscoVismDsx0MIBGroups 1 }
ciscoVismDsx0LineStatsGroup OBJECT-GROUP
OBJECTS {
ds0LineNum,
lineTotalDs0Count,
lineFreeDs0Count,
lineActiveDs0Count,
lineBlockDs0Count,
lineActiveHighWaterMark,
lineStatsClrButton
}
STATUS current
DESCRIPTION
"The collection of objects used for
DS0 Line statistics."
::= { ciscoVismDsx0MIBGroups 2 }
ciscoVismDsx0StatusGroup OBJECT-GROUP
OBJECTS {
ds0LineNumber,
ds0Number,
ds0Status,
ds0StatusClrButton
}
STATUS current
DESCRIPTION
"The collection of objects used for
DS0 status."
::= { ciscoVismDsx0MIBGroups 3 }
ciscoVismDsx0ConfGroup OBJECT-GROUP
OBJECTS {
ds0IfIndex,
ds0RobbedBitSignalling,
ds0IdleCode,
ds0SeizedCode,
ds0ReceivedCode,
ds0BundleMapped,
ds0IfType,
ds0CasVariantName,
ds0CasCadenceOnTime ,
ds0CasCadenceOffTime,
ds0InsertLocalCas,
ds0LocalCasPattern,
ds0LoopbackCommand,
ds0CasParameterSource,
ds0CasOnHookMinMakeTime,
ds0CasOffHookMinMakeTime,
ds0CasWinkMinMakeTime,
ds0CasWinkMaxMakeTime,
ds0CasWinkBreakTime,
ds0CasGlareTime,
ds0CasGaurdTime,
ds0CasDelayImmedStart,
ds0SignalingType,
ds0CasMinDelayDialTime,
ds0CasMinStartDialTime ,
ds0CasFlashMinMakeTime,
ds0CasFlashMaxMakeTime,
ds0CasDirectionality,
ds0CasGlarePolicy,
ds0CasIncomingMgcpPackage,
ds0CasOutgoingMgcpPackage,
ds0InputGain,
ds0OutputAttenuation,
ds0MusicThreshold,
ds0SidPacket,
ds0ExecDiag
}
STATUS deprecated
DESCRIPTION
"The collection of objects used for
DS0 configuration in VISM module."
::= { ciscoVismDsx0MIBGroups 4 }
ciscoVismDsx0ConfGroup2 OBJECT-GROUP
OBJECTS {
ds0IfIndex,
ds0RobbedBitSignalling,
ds0IdleCode,
ds0SeizedCode,
ds0ReceivedCode,
ds0BundleMapped,
ds0IfType,
ds0CasVariantName,
ds0CasCadenceOnTime ,
ds0CasCadenceOffTime,
ds0InsertLocalCas,
ds0LocalCasPattern,
ds0LoopbackCommand,
ds0CasParameterSource,
ds0CasOnHookMinMakeTime,
ds0CasOffHookMinMakeTime,
ds0CasWinkMinMakeTime,
ds0CasWinkMaxMakeTime,
ds0CasWinkBreakTime,
ds0CasGlareTime,
ds0CasGaurdTime,
ds0CasDelayImmedStart,
ds0SignalingType,
ds0CasMinDelayDialTime,
ds0CasMinStartDialTime ,
ds0CasFlashMinMakeTime,
ds0CasFlashMaxMakeTime,
ds0CasDirectionality,
ds0CasGlarePolicy,
ds0CasIncomingMgcpPackage,
ds0CasOutgoingMgcpPackage,
ds0InputGain,
ds0OutputAttenuation,
ds0MusicThreshold,
ds0SidPacket,
ds0ExecDiag,
ds0Companding,
ds0RxCasTransTblName,
ds0TxCasTransTblName,
ds0TxRxCasConfig
}
STATUS current
DESCRIPTION
"The collection of objects used for
DS0 configuration in VISM module."
::= { ciscoVismDsx0MIBGroups 7 }
ciscoVismDsx0ChanMapGroup OBJECT-GROUP
OBJECTS {
dsx1LineNum,
ds0ChanNum ,
ds0ChanMapIfIndex
}
STATUS current
DESCRIPTION
"The collection of objects used for
mapping DS0 to ifIndex."
::= { ciscoVismDsx0MIBGroups 5 }
ciscoVismDsx0ConfDeprecatedGroup OBJECT-GROUP
OBJECTS {
ds0TransmitCodesEnable
}
STATUS deprecated
DESCRIPTION
"The collection of objects that were
supported earlier but deprecated now."
::= { ciscoVismDsx0MIBGroups 6 }
END