-- CISCO-VOA-MIB.my
--
-- May 2002, Sonal Maheshwari, Mickey Spiegel
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
CISCO-VOA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TimeStamp FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
OpticalIfDirection FROM CISCO-OPTICAL-MONITOR-MIB
ciscoMgmt FROM CISCO-SMI
;
ciscoVoaMIB MODULE-IDENTITY
LAST-UPDATED "200205070000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO "Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
Tel: +1 800 553-NETS
E-mail: cs-dwdm@cisco.com"
DESCRIPTION
"This MIB module defines objects to configure and manage the
Variable Optical Attenuator (VOA) modules.
VOA modules are typically used to attenuate channels added
by a network element, in order to equalize the input power of
each wavelength before the multiplexed signal consisting of
all wavelengths is sent through an EDFA. There may be
a separate VOA per channel, one VOA per band of wavelengths,
or one VOA for the pass through wavelengths.
VOA modules are also often used before terminating optical
wavelengths at optical receivers, in order to avoid receiver
saturation.
The VOAs may be present on various modules within the network
element, for example, on an Optical Add/Drop Multiplexer
(OADM) module, on the same module as an optical transceiver,
or on a separate module of its own.
"
REVISION "200205070000Z"
DESCRIPTION
"The initial revision of this MIB."
::= { ciscoMgmt 262 }
-- Textual Conventions
OpticalPowerInDbm ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer value that gives the optical power level in 1/10ths
of dBm.
Example: The value -300 represents a power level of -30.0 dBm.
The distinguished value of '-1000' indicates that the object
has not yet been initialized.
"
SYNTAX Integer32 ( -400..250 | -1000 )
OpticalAttenInDb ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer value that gives the attenuation level in
1/10ths of dB.
Example: The value 80 represents an attenuation
level of 8.0 dB.
"
SYNTAX Integer32 (0..400)
-- MIB Object Definitions
cVoaMIBObjects OBJECT IDENTIFIER ::= { ciscoVoaMIB 1 }
-- groups in this MIB module
cVoaBaseGroup OBJECT IDENTIFIER ::= { cVoaMIBObjects 1 }
-- VOA basic objects
cVoaTable OBJECT-TYPE
SYNTAX SEQUENCE OF CVoaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides objects to configure and control the
attenuation on VOAs."
::={ cVoaBaseGroup 1 }
cVoaEntry OBJECT-TYPE
SYNTAX CVoaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cVoaTable provides objects to configure and
control the attenuation level of a VOA at an interface, for
a given direction."
INDEX { ifIndex, cVoaDirection }
::={ cVoaTable 1 }
CVoaEntry ::= SEQUENCE {
cVoaDirection OpticalIfDirection,
cVoaAttenuationControlMode INTEGER,
cVoaAttenuation OpticalAttenInDb,
cVoaAttenuationLastChange TimeStamp,
cVoaDesiredPower OpticalPowerInDbm
}
cVoaDirection OBJECT-TYPE
SYNTAX OpticalIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the second index into the cVoaTable and indicates
the direction for which the attenuation level at this
interface is being controlled, in this entry."
::={ cVoaEntry 1 }
cVoaAttenuationControlMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
automatic(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the mode of controlling the
attenuation level of a VOA at an interface.
When the mode is set to 'manual', the attenuation level is
configured manually, by setting the desired attenuation
level in the cVoaAttenuation object. The cVoaDesiredPower
object does not apply in this case.
When the mode is set to 'automatic', the attenuation level
is continuously adjusted to maintain a desired power level,
after attenuation. The desired optical power level after
attenuation is configured using the cVoaDesiredPower object.
The cVoaAttenuation object cannot be configured in this case,
but it indicates the attenuation level derived from the
desired power level.
The automatic mode of controlling attenuation should not be
used when the monitored power level includes multiple
wavelengths, since the power level monitor cannot distinguish
between a decrease in power across all wavelengths, versus a
loss of power of some but not all wavelengths. If some but not
all wavelengths go down, this would cause the attenuation level
to be automatically decreased, leading to an increase in the
power level of the remaining wavelengths."
::={ cVoaEntry 2 }
cVoaAttenuation OBJECT-TYPE
SYNTAX OpticalAttenInDb
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the attenuation level applied at the
interface.
When the cVoaAttenuationControlMode object is set to 'manual',
the attenuation level may be specified by setting this object."
::={ cVoaEntry 3 }
cVoaAttenuationLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the value of sysUpTime at the last
time the attenuation level was adjusted at this interface,
in the given direction."
::={ cVoaEntry 4 }
cVoaDesiredPower OBJECT-TYPE
SYNTAX OpticalPowerInDbm
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the desired optical power level,
after attenuation, at the interface.
This object applies only when the cVoaAttenuationControlMode
object is set to 'automatic'. In this mode, the attenuation
level is continuously adjusted to maintain the desired
power level, after attenuation, as specified by this object."
::={ cVoaEntry 5 }
-- MIB Conformance Statements
cVoaMIBConformance OBJECT IDENTIFIER ::= { ciscoVoaMIB 3 }
cVoaMIBCompliances OBJECT IDENTIFIER ::= { cVoaMIBConformance 1 }
cVoaMIBGroups OBJECT IDENTIFIER ::= { cVoaMIBConformance 2 }
cVoaMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for platforms that provide
configuration and control of VOA modules."
MODULE -- this module
MANDATORY-GROUPS { cVoaMIBBaseGroup }
::={ cVoaMIBCompliances 1 }
-- Units of Conformance
cVoaMIBBaseGroup OBJECT-GROUP
OBJECTS {
cVoaAttenuationControlMode,
cVoaAttenuation,
cVoaAttenuationLastChange,
cVoaDesiredPower
}
STATUS current
DESCRIPTION
"A collection of mandatory managed objects that provide basic
configuration and control of the VOA modules."
::={ cVoaMIBGroups 1 }
END