mibs/MIBS/cisco/CISCOSB-CPU-COUNTERS-MIB

171 lines
5.2 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CISCOSB-CPU-COUNTERS-MIB DEFINITIONS ::= BEGIN
IMPORTS
switch001 FROM CISCOSB-MIB
Counter32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
DisplayString,
TruthValue FROM SNMPv2-TC;
-- module
rlCpuCounters MODULE-IDENTITY
LAST-UPDATED "2007010600Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"CPU Counter MIBs"
REVISION "200705150000Z"
DESCRIPTION
"Initial revision."
::={ switch001 124 }
-- table
rlCpuCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCpuCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of rx&tx counter, the key is cpuCounters"
::= { rlCpuCounters 1 }
--entry:
rlCpuCountersEntry OBJECT-TYPE
SYNTAX RlCpuCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of rx&tx counters, the key is cpuCounters"
INDEX { rlCpuCountersTarget }
::= { rlCpuCountersTable 1 }
--entry content
RlCpuCountersEntry ::= SEQUENCE {
rlCpuCountersTarget INTEGER,
rlCpuCountersTxBC Counter32,
rlCpuCountersTxMC Counter32,
rlCpuCountersTxUC Counter32,
rlCpuCountersTxOctets Counter32,
rlCpuCountersRxBC Counter32,
rlCpuCountersRxMC Counter32,
rlCpuCountersRxUC Counter32,
rlCpuCountersRxOctets Counter32
}
--field definition:
rlCpuCountersTarget OBJECT-TYPE
SYNTAX INTEGER {
cpuCounters (0)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Packet type can be Multicast (MC), Broadcast (BC) or Unicast(UC)"
::= { rlCpuCountersEntry 1 }
rlCpuCountersTxBC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received broadcast packets."
::= { rlCpuCountersEntry 2 }
rlCpuCountersTxMC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted multicast packets."
::= { rlCpuCountersEntry 3 }
rlCpuCountersTxUC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted unicast packets."
::= { rlCpuCountersEntry 4 }
rlCpuCountersTxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted octets."
::= { rlCpuCountersEntry 5 }
rlCpuCountersRxBC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received broadcast packets."
::= { rlCpuCountersEntry 6 }
rlCpuCountersRxMC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received mutlicast packets."
::= { rlCpuCountersEntry 7 }
rlCpuCountersRxUC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received unicast packets."
::= { rlCpuCountersEntry 8 }
rlCpuCountersRxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received octets"
::= { rlCpuCountersEntry 9 }
-- rlCpuCountersReset:
rlCpuCountersReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting true to this MIB object will reset the CPU counters."
DEFVAL { false}
::= { rlCpuCounters 2 }
-- rlCpuCountersEnabled:
rlCpuCountersEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - feature is enabled, false - feature is disabled "
DEFVAL { false}
::= { rlCpuCounters 3 }
END