mibs/MIBS/cisco/CISCOSB-EVENTS-MIB

560 lines
21 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CISCOSB-EVENTS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString,
TruthValue, RowStatus FROM SNMPv2-TC
switch001 FROM CISCOSB-MIB
Counter FROM RFC1155-SMI
InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
RlSmartPortsMacroNameOrZero FROM CISCOSB-SMARTPORTS-MIB;
rlEventsMib MODULE-IDENTITY
LAST-UPDATED "201009110000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"MTS events MIB."
REVISION "201009110000Z"
DESCRIPTION
"Initial revision."
::= { switch001 150 }
--
-- rlEvents MIB
--
SmartPortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Supported smart port types."
SYNTAX INTEGER {
unknown(1),
default(2),
printer(3),
desktop(4),
guest(5),
server(6),
host(7),
ip-camera(8),
ip-phone(9),
ip-phone-desktop(10),
switch(11),
router(12),
ap(13)
}
SmartPortMacroParameterName ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Smart macro parameter name."
SYNTAX DisplayString(SIZE(1..32))
SmartPortMacroParameterValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Smart macro parameter value."
SYNTAX DisplayString(SIZE(1..80))
SmartPortMacroType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Smart macro type - built-in or user-defined."
SYNTAX INTEGER {built-in(1), user-defined(2)}
SmartPortMacroParameterOrder ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Smart macro parameter order."
SYNTAX INTEGER {single(1), first(2), middle(3), last(4)}
rlPortEvents OBJECT IDENTIFIER ::= { rlEventsMib 1}
rlAutoSmartPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2),
controlled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"disabled - Auto Smart port feature is administratively disabled.
enabled - Auto Smart port feature is administratively enabled.
controlled - Auto Smart port feature is administratively controlled by VOICE VLAN.
"
DEFVAL {controlled}
::= { rlPortEvents 1 }
rlAutoSmartPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"disabled - Auto Smart port feature is operationally disabled.
enabled - Auto Smart port feature is operationally enabled.
"
DEFVAL {disabled}
::= { rlPortEvents 2 }
rlAutoSmartPortLastVoiceVlanStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicated last status set by VOICE VLAN feature.
If rlAutoSmartPortAdminStatus has 'controlled' value then the value of this object is the same as rlAutoSmartPortOperStatus.
enabled - Auto Smart port feature should be operationally enabled, if rlAutoSmartPortAdminStatus has 'controlled' value.
disabled - Auto Smart port feature should be operationally disabled, if rlAutoSmartPortAdminStatus has 'controlled' value
"
DEFVAL {disabled}
::= { rlPortEvents 3}
rlAutoSmartPortLastVoiceVlanId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicated last VOICE VLAN ID set by VOICE VLAN feature."
::= { rlPortEvents 4}
rlAutoSmartPortLearningProtocols OBJECT-TYPE
SYNTAX BITS {
cdp (0),
lldp (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"cdp - Information about device type of neighboring devices(s) is learnt
via CDP (Cisco Discovery Protocol) advertisements.
lldp - Information about device type of neighboring devices(s) is learnt
via LLDP (Link Layer Discovery Protocol ) advertisements. "
::= { rlPortEvents 5 }
rlAutoSmartPortTypesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlAutoSmartPortTypesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to keep all the information related to a specific port type."
::= { rlPortEvents 6 }
rlAutoSmartPortTypesEntry OBJECT-TYPE
SYNTAX RlAutoSmartPortTypesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the rlAutoSmartPortTypesTable."
INDEX { rlAutoSmartPortTypesType }
::= { rlAutoSmartPortTypesTable 1 }
RlAutoSmartPortTypesEntry ::= SEQUENCE {
rlAutoSmartPortTypesType SmartPortType,
rlAutoSmartPortTypeStatus INTEGER,
rlAutoSmartPortMacro RlSmartPortsMacroNameOrZero,
rlAutoSmartPortTypesRevertToDefaultMacro TruthValue,
rlAutoSmartPortTypesRevertToDefaultParams TruthValue,
rlAutoSmartPortTypesBuiltinMacro SmartPortMacroType
}
rlAutoSmartPortTypesType OBJECT-TYPE
SYNTAX SmartPortType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Smart port type."
::= { rlAutoSmartPortTypesEntry 1 }
rlAutoSmartPortTypeStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2), default(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Smart port type global status. "
::= { rlAutoSmartPortTypesEntry 2 }
rlAutoSmartPortMacro OBJECT-TYPE
SYNTAX RlSmartPortsMacroNameOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Macro to be activated when a port is set to the smart port type indicated
by rlAutoSmartPortTypesType. The macro whose name is 'no_'<rlAutoSmartPortMacro>
is activated when a port ceases to be of this smart port type. "
::= { rlAutoSmartPortTypesEntry 3 }
rlAutoSmartPortTypesRevertToDefaultMacro OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object will cause the smart port type macro associated with this smart port type
to revert to the default macro. "
::= { rlAutoSmartPortTypesEntry 4 }
rlAutoSmartPortTypesRevertToDefaultParams OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object will cause the default smart port type parameter values associated with the built-in macro
of this smart port type to revert to their default values."
::= { rlAutoSmartPortTypesEntry 5 }
rlAutoSmartPortTypesBuiltinMacro OBJECT-TYPE
SYNTAX SmartPortMacroType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the macro is built-in or user defined."
::= { rlAutoSmartPortTypesEntry 6 }
rlAutoSmartPortMacrosParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlAutoSmartPortMacrosParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to keep all the default parameter values related to a specific port type."
::= { rlPortEvents 7 }
rlAutoSmartPortMacrosParamEntry OBJECT-TYPE
SYNTAX RlAutoSmartPortMacrosParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A parameter name & default value pair for a smart port type macro."
INDEX { rlAutoSmartPortTypesType, rlAutoSmartPortMacroType, IMPLIED rlAutoSmartPortMacrosParamName }
::= { rlAutoSmartPortMacrosParamTable 1 }
RlAutoSmartPortMacrosParamEntry ::= SEQUENCE {
rlAutoSmartPortMacroType SmartPortMacroType,
rlAutoSmartPortMacrosParamName SmartPortMacroParameterName,
rlAutoSmartPortMacrosParamOrder SmartPortMacroParameterOrder,
rlAutoSmartPortMacrosParamValue SmartPortMacroParameterValue
}
rlAutoSmartPortMacroType OBJECT-TYPE
SYNTAX SmartPortMacroType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Macro type - built-in or user defined."
::= { rlAutoSmartPortMacrosParamEntry 1 }
rlAutoSmartPortMacrosParamName OBJECT-TYPE
SYNTAX SmartPortMacroParameterName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name of the parameter to be supplied at smart port macro activation. "
::= { rlAutoSmartPortMacrosParamEntry 2 }
rlAutoSmartPortMacrosParamOrder OBJECT-TYPE
SYNTAX SmartPortMacroParameterOrder
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'first' instructs the system to erase all previous information associated
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
Setting this object to 'middle' instructs the system to wait for further parameters.
Setting this object to 'last' informs the system that no further parameters will be sent and
therefore it can start the macro or builtin parameters change process.
Setting this object to 'single' instructs the system to erase all previous information associated
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
informs the system that no further parameters will be sent and therefore it can start macro or builtin
parameters change process."
::= { rlAutoSmartPortMacrosParamEntry 3 }
rlAutoSmartPortMacrosParamValue OBJECT-TYPE
SYNTAX SmartPortMacroParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default value of the parameter to be supplied at smart port macro activation. "
::= { rlAutoSmartPortMacrosParamEntry 4 }
rlAutoSmartPortPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlAutoSmartPortPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to keep all the auto smart port information related to a specific port."
::= { rlPortEvents 8 }
rlAutoSmartPortPortsEntry OBJECT-TYPE
SYNTAX RlAutoSmartPortPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the rlAutoSmartPortPortsTable."
INDEX { rlAutoSmartPortPort }
::= { rlAutoSmartPortPortsTable 1 }
RlAutoSmartPortPortsEntry ::= SEQUENCE {
rlAutoSmartPortPort InterfaceIndex,
rlAutoSmartPortPortStatus INTEGER,
rlAutoSmartPortPortType SmartPortType,
rlAutoSmartPortPersistency INTEGER,
rlAutoSmartPortLearntPortType SmartPortType,
rlAutoSmartPortPortAcquiringType INTEGER,
rlAutoSmartPortLastActivatedMacro RlSmartPortsMacroNameOrZero,
rlAutoSmartPortFailedCommandNumber INTEGER,
rlAutoSmartPortSetLearntPortType TruthValue
}
rlAutoSmartPortPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port to which the smartport information is associated."
::= { rlAutoSmartPortPortsEntry 1 }
rlAutoSmartPortPortStatus OBJECT-TYPE
SYNTAX INTEGER {enabled(1), disabled(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether auto smart port feature is enabled or not on this port."
DEFVAL { enabled }
::= { rlAutoSmartPortPortsEntry 2 }
rlAutoSmartPortPortType OBJECT-TYPE
SYNTAX SmartPortType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Smart port type associated with this port. If set by user, the port will retain
the smart port type at link down, link not present and reboot events."
DEFVAL { default }
::= { rlAutoSmartPortPortsEntry 3 }
rlAutoSmartPortPersistency OBJECT-TYPE
SYNTAX INTEGER {persistent(1), not-persistent(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to persistent then, if the system concludes, according to
the information learnt there is no relevant device connected to the port,
the rlAutoSmartPortPortType will not be changed (as if the user set this
rlAutoSmartPortPortType himself), except on learning another rlAutoSmartPortPortType."
DEFVAL { not-persistent }
::= { rlAutoSmartPortPortsEntry 4 }
rlAutoSmartPortLearntPortType OBJECT-TYPE
SYNTAX SmartPortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Smart port type learnt via the learning protocols. This value will
be different from rlAutoSmartPortPortType only if rlAutoSmartPortPortType
was manually configured (i.e. if the value of
rlAutoSmartPortPortAcquiringType is 'configuration'). The value of the object
is used to set the value of rlAutoSmartPortPortType
if the user removes the configuration."
DEFVAL { default }
::= { rlAutoSmartPortPortsEntry 5 }
rlAutoSmartPortPortAcquiringType OBJECT-TYPE
SYNTAX INTEGER {default(1), configuration(2), persistency(3), learning(4)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the way that the value of rlAutoSmartPortPortType was acquired. This object can be
set only during configuration download."
::= { rlAutoSmartPortPortsEntry 6 }
rlAutoSmartPortLastActivatedMacro OBJECT-TYPE
SYNTAX RlSmartPortsMacroNameOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates macro name of last activated macro or 'no macro' if no macro was run."
::= { rlAutoSmartPortPortsEntry 7 }
rlAutoSmartPortFailedCommandNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates number of command (starting with 1) that caused the macro
failure or 0 if the macro succeeded or no macro was run."
::= { rlAutoSmartPortPortsEntry 8 }
rlAutoSmartPortSetLearntPortType OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Instructs the system to set the port type to the learnt port type."
::= { rlAutoSmartPortPortsEntry 9 }
rlAutoSmartPortParamsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlAutoSmartPortActionParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table optionally determines the parameter values for the macro that is activated when the smartport type is
manually changed for a specific port or trunk via the rlAutoSmartPortPortType object."
::= { rlPortEvents 9 }
rlAutoSmartPortParamsEntry OBJECT-TYPE
SYNTAX RlAutoSmartPortActionParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A parameter name & immediate value."
INDEX { rlAutoSmartPortIfIndex, IMPLIED rlAutoSmartPortParamName }
::= { rlAutoSmartPortParamsTable 1 }
RlAutoSmartPortActionParamsEntry ::= SEQUENCE {
rlAutoSmartPortIfIndex InterfaceIndex,
rlAutoSmartPortParamName SmartPortMacroParameterName,
rlAutoSmartPortParamOrder SmartPortMacroParameterOrder,
rlAutoSmartPortParamValue SmartPortMacroParameterValue
}
rlAutoSmartPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port or trunk that this entry is associated with. "
::= { rlAutoSmartPortParamsEntry 1 }
rlAutoSmartPortParamName OBJECT-TYPE
SYNTAX SmartPortMacroParameterName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name of the parameter whose value must be supplied at a smart port macro activation. "
::= { rlAutoSmartPortParamsEntry 2 }
rlAutoSmartPortParamOrder OBJECT-TYPE
SYNTAX SmartPortMacroParameterOrder
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'first' instructs the system to erase all previous information associated
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
Setting this object to 'middle' instructs the system to wait for further parameters.
Setting this object to 'last' informs the system that no further parameters will be sent and
therefore it can start applying the smartport type.
Setting this object to 'single' instructs the system to erase all previous information associated
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
informs the system that no further parameters will be sent and informs the system that no further parameters will be sent and
therefore it can start applying the smartport type."
::= { rlAutoSmartPortParamsEntry 3 }
rlAutoSmartPortParamValue OBJECT-TYPE
SYNTAX SmartPortMacroParameterValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Value of the parameter whose value must be supplied at a smart port macro activation. "
::= { rlAutoSmartPortParamsEntry 4 }
rlAutoSmartTrunkRefreshTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlAutoSmartTrunkRefreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Setting this object causes running the SmartPort macros of the
following types: router, switch and ap. This operation is called the trunk refresh operation."
::= { rlPortEvents 10 }
rlAutoSmartTrunkRefreshEntry OBJECT-TYPE
SYNTAX RlAutoSmartTrunkRefreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the rlAutoSmartTrunkRefreshTable."
INDEX { rlAutoSmartTrunkRefreshSmartPortType, rlAutoSmartTrunkRefreshIfIndex }
::= { rlAutoSmartTrunkRefreshTable 1 }
RlAutoSmartTrunkRefreshEntry ::= SEQUENCE {
rlAutoSmartTrunkRefreshSmartPortType INTEGER,
rlAutoSmartTrunkRefreshIfIndex InterfaceIndexOrZero,
rlAutoSmartTrunkRefreshRowStatus RowStatus
}
rlAutoSmartTrunkRefreshSmartPortType OBJECT-TYPE
SYNTAX INTEGER {default(1), switch(11), router(12), ap(13)}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"If not default the trunk refresh operation will be carried out on all ports of this smart port type if
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex if it's type
matches the given this smart port type (if not matching a wrong-value error will be return).
If default the trunk refresh operation will be carried out on all ports of router, switch and ap smart port type if
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex."
::= { rlAutoSmartTrunkRefreshEntry 1 }
rlAutoSmartTrunkRefreshIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"If 0 the trunk refresh operation will be carried out on all ports of the smart port type as specified in the
rlAutoSmartTrunkRefreshSmartPortType. If nonzero the trunk refresh operation will be carried out
on the specified port, if rlAutoSmartTrunkRefreshSmartPortType is default or matches the smart port type of
the specified port. Any other case will result in a wrong-value error."
::= { rlAutoSmartTrunkRefreshEntry 2 }
rlAutoSmartTrunkRefreshRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Since this an action table only createAndGo will be accepted and the conceptual row will vanish immediately
after the action execution."
::= { rlAutoSmartTrunkRefreshEntry 3 }
rlAutoSmartBusy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true indicates that the autosmartports system is temporarily busy performing a multiport
operation and therefore can not service management requests for the time-being."
::= { rlPortEvents 11 }
END