mibs/MIBS/cisco/SA-CM-MIB

1541 lines
53 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--**************************************************************************
--
-- Copyright 2011 Cisco Systems, Inc.
-- All Rights Reserved
-- No portions of this material may be reproduced in any
-- form without the written permission of:
-- Cisco Systems Inc.
-- 170 West Tasman Dr.
-- San Jose, CA 95134
-- USA
--**************************************************************************
SA-CM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,enterprises,
Counter32,
Integer32,
IpAddress
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,
MacAddress,DisplayString,
TruthValue, RowStatus, DateAndTime,
TDomain, TAddress
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC2571
ifIndex
FROM IF-MIB
InetAddressType,
InetAddress,
InetPortNumber
FROM INET-ADDRESS-MIB;
sa OBJECT IDENTIFIER ::= { enterprises 1429 }
saCmMib MODULE-IDENTITY
LAST-UPDATED "201505260000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO "support.cisco.com"
DESCRIPTION
"Cisco Cable Modem MIB definition"
-- history
REVISION "201605180000Z" -- 2016/05/18
DESCRIPTION "Added saCmSoftwareDownload tree"
REVISION "201505260000Z"
DESCRIPTION "Initial release of reduced-set module for releases based on BFC 5.7.x."
::= { sa 77 }
-- Generic information
dpxCmMibObjects OBJECT IDENTIFIER ::= { saCmMib 1 }
--
-- General Information about the CableModem
--
cmVendorInfo OBJECT IDENTIFIER ::= { dpxCmMibObjects 2}
cmAPInfo OBJECT IDENTIFIER ::= { dpxCmMibObjects 3}
cmInterfaceInfo OBJECT IDENTIFIER ::= { dpxCmMibObjects 4}
vendorDefaultDSfreq OBJECT-TYPE
SYNTAX Integer32 (93000000..855000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
DOCSIS:
initial downstream frequency,
range: 93000000 to 855000000 Hz
EuroDOCSIS:
initial downstream frequency,
range: 88000000 to 859000000 Hz
"
::= { cmVendorInfo 6 }
vendorDSLEDTreatment OBJECT-TYPE
SYNTAX INTEGER {
signalNB(0),
signalWB(1),
signalWBNBG(2),
signalWBNBA(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This MIB is only valid in DOCSIS 3.0 enabled modems with dual LEDs.
This MIB determines the DS LED color, green or amber, to be used to indicate DS state.
signalNB: DS LED = amber for narrowband; DS LED = green when DS w-online wideband.
signalWB: DS LED = amber for wideband; DS LED = green when DS online narrowband.
signalWBNBG: Both WB and NB states are indicated using the Green LED.
signalWBNBA: Both WB and NB states are indicated using the Amber LED.
"
DEFVAL { 0 }
::= { cmVendorInfo 7 }
vendorLINKLEDTreatment OBJECT-TYPE
SYNTAX INTEGER {
default(0),
showlinkspeed(1),
d3Amberledslowspeed(2),
d3Greenledslowspeed(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This MIB will determine Link Speed using blink rate for DOCSIS 2.0 modems or
using LED color for DOCSIS 3.0 Modems as seen with the LINK LED.
default: LINK LED behavior follows standard behavior as defined per User Guide
FOR DOCSIS 2.0
1: showlinkspeed: When connected, LED blinks 1x/2sec for 10/100 operation
and blinks 2x/1sec for Gigabit operation. Traffic is still reflected as
2x/1sec.
FOR DOCSIS 3.0
On dual LED D3.0 modems the operator can choose to have 10/100 operation indicated by either
a green LED or an amber LED. Modems that support 1000 Mb speeds shall indicate using the
alternate LED.
2: d3Greenledslowspeed indicates 10/100 operation using the Green LED.
3: d3Amberledslowspeed indicates 10/100 operation using the Amber LED.
"
DEFVAL { 0 }
::= { cmVendorInfo 8 }
vendorUSLEDTreatment OBJECT-TYPE
SYNTAX INTEGER {
signalWBNBG(0),
signalNB(1),
signalWB(2),
signalWBNBA(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This MIB is only valid in DOCSIS 3.0 enabled modems with dual LEDs.
This MIB determines the US LED color, green or amber to be used to indicate US state.
signalWBNBG: Both WB and NB states are indicated using the Green LED.
signalNB: US LED = amber for narrowband; US LED = green when US w-online wideband.
signalWB: US LED = amber for wideband; US LED = green when US online narrowband.
signalWBNBA: Both WB and NB states are indicated using the Amber LED.
"
DEFVAL { 0 }
::= { cmVendorInfo 9 }
vendorONLINELEDTreatment OBJECT-TYPE
SYNTAX INTEGER {
signalWBNBG(0),
signalNB(1),
signalWB(2),
signalWBNBA(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This MIB is only valid in DOCSIS 3.0 enabled modems with dual LEDs.
This MIB provides a way to select the ONLINE LED color, green or amber to distinguish between
wideband online or online(NB).
signalWBNBG: Both WB and NB states are indicated using the Green LED.
signalNB: ONLINE LED = amber for narrowband; ONLINE LED = green when DS w-online wideband.
signalWB: ONLINE LED = amber for wideband; ONLINE LED = green when DS online narrowband.
signalWBNBA: Both WB and NB states are indicated using the Amber LED.
NOTE: This LED will only provide indication of a Downstream Bonded environment and does not
indicate the presence of Upstream bonding.
"
DEFVAL { 0 }
::= { cmVendorInfo 10 }
cmAPIgmp OBJECT-TYPE
SYNTAX INTEGER {
disableIGMP(0),
enableIGMP(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
0: disable IGMP proxy,
1: enable IGMP proxy"
::= { cmAPInfo 1 }
cmAPAgingOut OBJECT-TYPE
SYNTAX INTEGER {
disableAgingOut(0),
enableAgingOut(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
0: disable ARP aging out
1: enable ARP aging out"
::= { cmAPInfo 4 }
cmAPMulticastPromiscuousMode OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Support for transparent multicast pass-thru using Promiscuous Multicast Mode.
The setting will be stored in non-volatile memory and will be retained
through a power cycle. It can be forcibly cleared with a fatcory reset."
::= { cmAPInfo 13 }
cmAPInternalInterface OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the state of local interface.
0: Shut down local interface,
1: Leave local interface as is."
DEFVAL { 1 }
::= { cmAPInfo 15 }
cmAPFactoryReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Can be set with a sequence of values to activate a remote factory reset.
This is the same as a sustained ( 3 seconds or more ) reset switch.
Reading this object always returns false(2)."
::= { cmAPInfo 18 }
saCmArpRateLimit OBJECT-TYPE
SYNTAX INTEGER (0..100)
UNITS "packets-per-second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting ARP rate-limit defines the number of ARP packets
that can be processed per second. Limitation of this number
prevents denial-of-service attacks. A value of 20 pps is a
good reference. Setting the value to 0 allows unlimited
incoming ARP messages"
DEFVAL { 0 }
::= { cmAPInfo 19 }
saCmInternalDhcpServer OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the DHCP server that is used when CM is offline.
0: disable internal DHCP server
1: enable internal DHCP server"
DEFVAL { 1 }
::= { cmAPInfo 20 }
--
cmConsoleMode OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
readOnly(1),
readWrite(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To Control console port is disabled, read only, or read write"
DEFVAL { 0 }
::= { cmInterfaceInfo 7 }
cmTimerT4 OBJECT-TYPE
SYNTAX INTEGER (30..60)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"T4 timeout definition."
DEFVAL { 30 }
::= { cmInterfaceInfo 8 }
saCmTodRenewal OBJECT-TYPE
SYNTAX INTEGER
UNITS "hours"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines how often to update time with ToD protocol.
0: never
1: together with DHCP renewal
2-11: reserved
12+: number of hours"
DEFVAL { 0 }
::= { cmInterfaceInfo 9 }
saCmAutoResetNoActivity OBJECT-TYPE
SYNTAX INTEGER (0..43200)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to any value N > 0 will cause the CM to reboot autonomously
3/4th of N minutes after the modem has detected that there is no connectivity to the CM gateway after three unsuccessful pings.
NOTE: The default value of 0 means the feature is disabled."
DEFVAL { 0 }
::= { cmInterfaceInfo 10 }
saCmCpeMacAging OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to any value N > 0 will cause the CM to remove a MAC address
from its CPE table N seconds after the modem has detected no traffic from it.
This feature applies ONLY to devices connected to the CM, not the embedded ones
(as MTA or CableHome).
NOTE: The default value of 0 means the feature is disabled."
DEFVAL { 0 }
::= { cmInterfaceInfo 11 }
saCmBpiForward OBJECT-TYPE
SYNTAX INTEGER {
macTable(1),
allPackets(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls whether to forward traffic that is not
destined for any CPE (not in CPE table) when running BPI.
1: follow DOCSIS rules. Do not forward traffic when destination
MAC not in the CPE table.
2: when BPI is enabled, forward all traffic (if security
association matches, otherwise cannot decrypt packets).
When BPI is disabled, this object does not have effect."
DEFVAL { 1 }
::= { cmInterfaceInfo 12 }
saCmForceDualscan OBJECT-TYPE
SYNTAX INTEGER {
useFactorySetting(0),
enable(1),
docsis1(2),
euroDocsis(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MIB will choose whether to force dualscan
operation for the device. Dualscan refers to the
CM ability to automatically scan for both 6MHz and
8MHz carriers.
0 : Will not force dualscan. In this case, the
factory configuration for dualscan will take
effect.
*note: Factory Dualscan configuration is
typically only enabled for EPC products.
1 : Will force dualscan to be enabled. In this
case, dualscan will be enabled regardless of
the factory setting.
This MIB value will be stored to NonVolatile
memory(NVM) and will persist across reboots. If
the MIB is set via the config file, the CM will
store the new setting and begin using it on next
reboot. Removing the setting from the config
file will not change the value stored in NVM the
CM will continue to operate using the previously
stored value.
However, if an SNMP SET is used to modify the
value, then the CM will not use the new setting
until the next reboot occurs or is commanded.
A factory reset of the CM will set the stored
value back to 0.
2 : *Docsis1 mode will only allow the modem to lock Annex B (6MHz) channels and will ignore all Annex A (8MHz) channels.
3 : *EuroDocsis mode will only allow the modem to lock Annex A (8MHz) channesl and will ignore all Annex B (6 MHz)channels.
*Feature available upon request for dualscan capable modems."
DEFVAL {0}
::= { cmInterfaceInfo 14 }
saCmDsBonding OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1),
enable2DS(2),
enable3DS(3),
enable4DS(4),
enable5DS(5),
enable6DS(6),
enable7DS(7),
enable8DS(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MIB will choose whether to enable downstream
channel bonding for bonding-capable modems.
Non-bonding modems will ignore this MIB object.
0 : Disable downstream channel bonding.
1 : Enable downstream channel bonding
with all available RCP-IDs standard and proprietary.
2 : Enable downstream bonding but only advertise
standard RCP-IDs with 2 DS channels.
3 : Enable downstream bonding but only advertise
standard RCP-IDs with 3 or fewer DS channels.
4 : Enable downstream bonding but only advertise
standard RCP-IDs with 4 or fewer DS channels.
5 : Not currently applicable (same as 1)
6 : Not currently applicable (same as 1)
7 : Not currently applicable (same as 1)
8 : Enable downstream bonding but only advertise
standard RCP-IDs with 8 or fewer DS channels.
This MIB will take effect at the next reboot.
This MIB value will be stored to NonVolatile
memory(NVM) and will persist across reboots. If
the MIB is set via the config file, the CM will
store the new setting and reboot if a change is
necessary. Removing the setting from the config
file will not change the value stored in NVM: the
CM will continue to operate using the previously
stored value.
If an SNMP SET is used to modify the value, then
the CM will not use the new setting until the next
reboot occurs or is commanded.
A factory reset of the CM will set the stored
value back to 1."
DEFVAL { 1 }
::= { cmInterfaceInfo 15 }
saCmDocsisCapableVersion OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the string value for CM DHCP DISCOVER option 60 text.
This mib is only readable through SNMP.This MIB object can queried to identify the device's docsis version that it supports."
::= { cmInterfaceInfo 33 }
saOorDsidOverride OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This MIB is only valid on DOCSIS 3.0 capable modems.
This feature is disabled by default.
This MIB will modify the handling of OOR (Out of Range) DSID packets.
If disabled the modem will follow DOCSIS specifications for handling
OOR DSID packets.
If enabled the modem will not follow the DOCSIS specifications but will
recover much quicker from this error condition. Intead of 1000 OOR packets
or 2 minutes the modem will recover with 3 OOR packets or 1 second.
disabled(0): Follow DOCSIS specification (default)
enabled (1): Resync after 3 OOR DSIDs or 1 second
NOTE: The new setting will persist during reboots but a reboot of the modem
is performed automatically if the setting is changed.
"
DEFVAL { 0 }
::= { cmInterfaceInfo 34 }
saCmCpeL2VpnMacAging OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB defines same functionality as TLV 65 for L2VPN implementation. When the value is
is set to 1 (Enable), Mac aging implementation is as per cablelabs specification. This MIB
will only be enable for L2VPN images. This MIB should take precendence over saCmCpeMacAging,
If saCmCpeMacAging is set to a (non-zero) timer value and if saCmCpeL2VpnMacAging is set to
1, saCmCpeL2VpnMacAging implementation of CPE MacAging feature will take affect.
saCmCpeMacAging MIB set to non-zero value will only take affect if saCmCpeL2VpnMacAging is
set to disable (0)"
::= { cmInterfaceInfo 39 }
saCmL2VpnUsForwardingCriteria OBJECT-TYPE
SYNTAX INTEGER {
forwardOnPrimarySF(0),
discard(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to L2VPN enabled CMs only. This MIB defines the policy that the CM should use
when forwarding packets that do not match the upstream classifier criteria.
forwardOnPrimarySF(0) - Forward packets on the primary service flow
discard(1) - Discard packets"
DEFVAL { 0 }
::= { cmInterfaceInfo 40 }
cmEthernetOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmEthernetOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for Ethernet interface link speed, duplex, mode, and operation."
::= { cmInterfaceInfo 41 }
cmEthernetOperEntry OBJECT-TYPE
SYNTAX CmEthernetOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for Ethernet interface link speed, duplex, mode and operation."
INDEX { cmEthernetOperIndex}
::= { cmEthernetOperTable 1 }
CmEthernetOperEntry ::= SEQUENCE
{
cmEthernetOperIndex INTEGER,
cmEthernetOperSetting INTEGER,
cmEthernetOperMode INTEGER,
cmEthernetIfAdminStatus INTEGER
}
cmEthernetOperIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index used for the interfaces."
::= { cmEthernetOperEntry 1 }
cmEthernetOperSetting OBJECT-TYPE
SYNTAX INTEGER {
link-down (0),
half-duplex-10Mbps(1),
full-duplex-10Mbps(2),
half-duplex-100Mbps(3),
full-duplex-100Mbps(4),
ethernetNotConnected(5),
half-duplex-1Gbps(6),
full-duplex-1Gbps(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the current Ethernet port link speed and duplex.
0: link-down(0),
1: half-duplex-10Mbps(1),
2: full-duplex-10Mbps(2),
3: half-duplex-100Mbps(3),
4: full-duplex-100Mbps(4),
5: ethernetNotConnected(5),
6: half-duplex-1Gbps(6),
7: full-duplex-1Gbps(7)"
::= { cmEthernetOperEntry 2}
cmEthernetOperMode OBJECT-TYPE
SYNTAX INTEGER {
auto-negotiate(0),
manual(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the current Ethernet port speed and duplex link Mode.
1: Auto-negotiate(0)
2: Manual(1)"
::= { cmEthernetOperEntry 3}
cmEthernetIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For RG Mode this MIB provides a way to force the ifAdminStatus.x MIB settings
for the individual Ethernet ports to the values stored in cmEthernetAdminStatus.x.
This feature is activated by setting cmEthernetIfAdminOverride is set to enable(1).
Bridge mode is a special case since there is only one ifindex = .1 for all 4 ports.
In Bridge Mode this MIB still allows you control the port status per Ethernet interface.
However, the value of ifAdminStatus.1 and ifOperStatus.1 will follow the following logic:
If at least 1 port is set to up by cmEthernetIfAdminStatus.x then ifAdminStatus.x will be
set to up(1). If all ports are set to down by cmEthernetIfAdminStatus.x then
ifAdminStatus.1 will report down(2). ifAdminStatus.x will report testing(3) if all ports set
by cmEthernetIfAdminStatus.x are in testing(3) status.
The major use case for this MIB is to set specific unused ports on the RG to down(2) status
immediately after a reboot and prior to CM registration.
This MIB is written to non-vol and survives a reboot.
A factory reset sets MIB index values back to up(1).
1: up(1) Force the individual port to up(1).
2: down(2) Force the individual port to down(2)
3: testing(3) Force the port to testing status(3) No packets passed."
DEFVAL { 1 }
::= { cmEthernetOperEntry 4}
cmEthernetIfAdminOverride OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For RG Mode enabling this MIB forces the index values of cmEthernetifAdminStatus.x
stored in non-vol into ifAdminStatus.x
For Bridge Mode the ports are exclusively controlled by cmEthernetifAdminStatus.x
and ifAdminStatus.x has no direct mapping and is overridden.
This MIB is written to non-vol and survives a reboot.
A factory reset sets MIB index values back to disable(0)."
DEFVAL { 0 }
::= { cmInterfaceInfo 42 }
saCmUsBonding OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MIB will choose whether to advertise upstream
channel bonding for bonding-capable modems in the modem
capabilitiies during registration.
Non-DOCSIS 3.0 modems will not have this MIB object.
0 : Disable upstream channel bonding advertisement.
1 : Enable upstream channel bonding advertisement.
This MIB must be set in the config file to function.
This MIB can be read from SNMP for current value."
DEFVAL { 1 }
::= { cmInterfaceInfo 43 }
saCmIcmpRateLimit OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "packets-per-second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting ICMP rate-limit defines the number of ICMP packets
that can be processed per second. Limitation of this number
prevents denial-of-service attacks. Setting the value to 0
allows unlimited incoming ICMP messages.
The default value has been changed from 10 to 0 in 5.5.9 and
newer releases."
DEFVAL { 0 }
::= { cmInterfaceInfo 44 }
saCmTftpBlockSizeV4 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB controls the TFTP block size in IPv4 operation. Valid values are 0, 8-8192. A value
of 0 means to use the default block size of 1448 and do not negotiate block size. Any other
value must be comply with block size negotiation in RFC 1350, RFC 1782, and RFC2348.
This value is stored in nonvol."
DEFVAL { 0 }
::= {cmInterfaceInfo 46}
saCmTftpBlockSizeV6 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB controls the TFTP block size in IPv4 operation. Valid values are 0, 8-8192. A value
of 0 means to use the default block size of 1428 and do not negotiate block size. Any other
value must be comply with block size negotiation in RFC 1350, RFC 1782, and RFC2348.
This value is stored in nonvol."
DEFVAL { 0 }
::= {cmInterfaceInfo 47}
saCmUsPowerLimit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB controls the upstream power limit imposed on the cable modem (in dB)."
DEFVAL { 51 }
::= { cmInterfaceInfo 48 }
-- =====================================
-- HW SPECIFIC SOFTWARE DOWNLOAD OBJECTS
-- =====================================
--
-- This table defines an alternative method of downloading
-- new software to cable modems.
-- When a SA modem reads the config file and finds this table present,
-- it will do the following, for each row in the table:
-- 1. Compare saCmSwModel name to its own name.
-- If not the same, go to the next row in the table.
-- If not present or the same, go to 2.
-- 2. Compare saCmSwHwVer name to its own hardware version.
-- If not the same, go to the next row in the table.
-- If not present or the same, go to 3.
-- 3. Compare saCmSwBootLoader to its own boot loader.
-- If not the same, go to the next row in the table.
-- If not present or the same, go to 4.
-- 4. Compare saCmSwProto to its own signaling protocol.
-- If not present or the same or any(0), go to 5.
-- If not the same, go to the next row in the table.
-- 5. If saCmSwFilename is present, copy the value to docsDevSwFilename.
-- If saCmSwAdminStatus is present, copy the value to docsDevSwAdminStatus.
-- If saCmSwServer is present, copy the value to docsDevSwServer.
-- 6. If saCmSwMethod = unsecure(2), assume VSIF 38 = 1. If secure (1),
-- use CVC that comes with software.
-- 7. Exit the table.
-- If no rows are left, use config file TLVs for upgrading software.
--
-- Hint: The most specific rows (the ones that use saCmSwModel,
-- saCmSwHwVer and saCmSwProto) should be placed in the beginning
-- of the table.
saCmSoftwareDownload OBJECT IDENTIFIER ::= { dpxCmMibObjects 6 }
saCmSoftwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaCmSoftwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for hardware specific software download."
::= { saCmSoftwareDownload 1 }
saCmSoftwareEntry OBJECT-TYPE
SYNTAX SaCmSoftwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for hardware specific software download."
INDEX { saCmSwIndex }
::= { saCmSoftwareTable 1 }
SaCmSoftwareEntry ::= SEQUENCE
{
saCmSwIndex INTEGER,
saCmSwModel SnmpAdminString,
saCmSwHwVer SnmpAdminString,
saCmSwBootLoader SnmpAdminString,
saCmSwProtocol INTEGER,
saCmSwFilename SnmpAdminString,
saCmSwServer IpAddress,
saCmSwAdminStatus INTEGER,
saCmSwMethod INTEGER,
saCmSwServerAddressType InetAddressType,
saCmSwServerAddress InetAddress
}
saCmSwIndex OBJECT-TYPE
SYNTAX INTEGER (1..30)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index used to order the application of access entries."
::= { saCmSoftwareEntry 1 }
saCmSwModel OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Model name of the cable modem product.
If not set, applies to all models.
example: DPC2100"
::= { saCmSoftwareEntry 2 }
saCmSwHwVer OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Hardware version of the cable modem product.
If not set, applies to all versions."
DEFVAL { "any" }
::= { saCmSoftwareEntry 3 }
saCmSwBootLoader OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Boot loader version of the cable modem product.
If not set, applies to all versions."
DEFVAL { "any" }
::= { saCmSoftwareEntry 4 }
saCmSwProtocol OBJECT-TYPE
SYNTAX INTEGER {
any(0),
ncs(1),
sip(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Protocol used in cable modem product."
DEFVAL { 0 }
::= { saCmSoftwareEntry 5 }
saCmSwFilename OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..64))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Filename of the software image."
::= { saCmSoftwareEntry 6 }
saCmSwServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"TFTP server IP address where software image is located."
::= { saCmSoftwareEntry 7 }
saCmSwAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
saCmSwAllowProvisioningUpgrade(2),
saCmSwIgnoreProvisioningUpgrade(3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"See docsDevSwAdminStatus for details."
::= { saCmSoftwareEntry 8 }
saCmSwMethod OBJECT-TYPE
SYNTAX INTEGER {
secure(1),
unsecure(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Method of software download."
DEFVAL { 1 }
::= { saCmSoftwareEntry 9 }
saCmSwServerAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This MIB defines the type of internet address to be used for the TFTP Server.
0: An unknown address type. This value MUST
be used if the value of the corresponding
InetAddress object is a zero-length string.
It may also be used to indicate an IP address
that is not in one of the formats defined
below.
1 : IPv4 TFTP Server Address
2 : IPv6 TFTP Server Address (reserved for future support)"
::= { saCmSoftwareEntry 11 }
saCmSwServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TFTP server IP address where software image is located."
::= { saCmSoftwareEntry 12 }
saCmSoftwareDownloadTFTPServer OBJECT-TYPE
SYNTAX INTEGER {
sameAsCM(1),
dhcpOption54(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When CM configuration file initiated software upgrade is needed,
the TFTP request will be sent to SwUpgradeServer IP address.
When the value of SwUpgradeServer is not specified in the CM
configuration file then the TFTP request will be sent to the same
TFTP server used for CM configuration file download (1) or to the
IP address specified in DHCP Option 54 (2)."
DEFVAL { 1 }
::= { saCmSoftwareDownload 3 }
-- ============================================
-- END OF HW SPECIFIC SOFTWARE DOWNLOAD OBJECTS
-- ============================================
-- ===============
-- WEB ACCESS TREE
-- ===============
saCmWebAccess OBJECT IDENTIFIER ::= { dpxCmMibObjects 7 }
saCmWebAccessUserIfTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaCmWebAccessUserIfTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for various user/if type web access levels."
::= { saCmWebAccess 2 }
saCmWebAccessUserIfTypeEntry OBJECT-TYPE
SYNTAX SaCmWebAccessUserIfTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for various users/if type web access levels."
INDEX { saCmWebAccessUserTypeIndex,
saCmWebAccessIfTypeIndex }
::= { saCmWebAccessUserIfTypeTable 1 }
SaCmWebAccessUserIfTypeEntry ::= SEQUENCE
{
saCmWebAccessUserTypeIndex INTEGER,
saCmWebAccessIfTypeIndex INTEGER,
saCmWebAccessUserIfLevel INTEGER
}
saCmWebAccessUserTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
home-user(1),
cus-admin(5),
adv-user(10),
all-users(100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Access level for various user types.
home-user(1): This is intended to be used for home users
cus-admin(5): This is intended to be used for the CUSADMIN
adv-user(10): This type is intended to be used by MSO admin
all-users(100): This will be a write-only value and it's a
convenience provided to the MSO to specify that the same setting
takes effect for all users.
This index should not be available in an SNMP Walk/Get but
administrator should be able to set this value.
Example:
Scenario: MSO wants to disable the wan-rg access for home-user and
adv-user.
MIB Set: saCmWebAccessUserIfLevel.all-users.wan-rg = 0
MIB Walk: saCmWebAccessUserIfLevel.home-user.wan-rg = 0
saCmWebAccessUserIfLevel.adv-user.wan-rg = 0
Basically, MSO has a provision to set this MIB which will internally
fill the values for both users (and any other user types in future)
and they will be shown individually in an SNMP Walk"
::= { saCmWebAccessUserIfTypeEntry 1 }
saCmWebAccessIfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
lan(1),
rf-cm(2),
mta(16),
wan-rg(40),
all-ifs(100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Web access over various interface types.
lan(1): This will control the CPE interface on the lan side.
rf-cm(2): This will control the remote access to the web pages through
the CM public IP
mta(16): This will control the web-access through MTA interface
wan-rg(40): This will control the remote access to the web pages
through RG public IP
all-ifs(100): This will be a write-only value and it's a convenience
provided to the MSO to specify that the same setting will take effect
for all interfaces.
This index should not be available in an SNMP Walk/Get but
administrator should be able to set this value.
Example:
Scenario: MSO wants to disable the access to WEB pages (similar to
cmApWebSwitch = 0 now).
MIB Set: saCmWebAccessUserIfLevel.all-users.all-ifs = 0
MIB Walk: saCmWebAccessUserIfLevel.home-user.lan = 0
saCmWebAccessUserIfLevel.home-user.rf-cm = 0
saCmWebAccessUserIfLevel.home-user.mta = 0
saCmWebAccessUserIfLevel.home-user.wan-rg = 0
saCmWebAccessUserIfLevel.adv-user.lan = 0
saCmWebAccessUserIfLevel.adv-user.rf-cm = 0
saCmWebAccessUserIfLevel.adv-user.mta = 0
saCmWebAccessUserIfLevel.adv-user.wan-rg = 0
Basically, MSO has a provision to set this MIB which will internally
fill the values for all interfaces and they will be shown individually
in an SNMP Walk"
::= { saCmWebAccessUserIfTypeEntry 2 }
saCmWebAccessUserIfLevel OBJECT-TYPE
SYNTAX INTEGER {
not-applicable(-1),
off(0),
system(1),
basic(2),
readonly(3),
advanced(100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access levels for web pages.
not-applicable(-1) - This will be displayed if access level can not be determined
for any interface/user. In the case when the various interfaces have different access
levels, all-ifs value will show as not-applicable.
Example:
Configure the following values in modem config file
saCmWebAccessUserIfLevel.home-user.all-ifs = 100 and
saCmWebAccessUserIfLevel.adv-user.all-ifs is = 2
An SNMP walk on the saCmWebAccessUserIfLevel will provide the following
saCmWebAccessUserIfLevel.home-user.lan = advanced (100)
saCmWebAccessUserIfLevel.home-user.rf-cm = advanced (100)
saCmWebAccessUserIfLevel.home-user.mta = advanced (100)
saCmWebAccessUserIfLevel.home-user.wan-rg = advanced (100)
saCmWebAccessUserIfLevel.home-user.all-ifs = not-applicable (-1)
saCmWebAccessUserIfLevel.adv-user.lan = basic (2)
saCmWebAccessUserIfLevel.adv-user.rf-cm = basic (2)
saCmWebAccessUserIfLevel.adv-user.mta = basic (2)
saCmWebAccessUserIfLevel.adv-user.wan-rg = basic (2)
saCmWebAccessUserIfLevel.adv-user.all-ifs = not-applicable (-1)
off(0) - This will shut-down the port and this interface if the same
value is used for all users. If any of the user has a non-zero value
for this interface, this will be automatically treated as same as a
value 1.
systemOnly(1) - Login/Landing page will be displayed but user(s) will
not authenticate. This will display all the web pages available to the
user without login. Please refer to the Access Table section in the Web
GUI PRD to find out the details
basic(2) - The specified users can access only the basic pages after
login. Please refer to Access Table section in Web GUI PRD to find out
the details about Basic Access
readonly (3) - This will provide read-only access to users specified
from the interface selected. The pages displayed in readOnly mode will
be same as if the user had the access level set to advanced except
that pages are not editable.
Please refer to the appropriate columns of Access Table in the Web GUI
PRD for understanding what pages need to be displayed to the
home-user/adv-user in Online/Offline status.
This value if set, will take precedence over saCmWebAccessWritePages
Example:
Page 1 - saCmWebAccessReadPages = 1, saCmWebAccessWritePages = 1,
Page 2 - saCmWebAccessReadPages = 1, saCmWebAccessWritePages = 0,
Page 3 - saCmWebAccessReadPages = 0, saCmWebAccessWritePages = 0
Scenario 1:
saCmWebAccessUserIfLevel.all-users.all-ifs = 100
Result: Display Page1 and Page 2 with read-write access to Page 1
Scenario 2:
saCmWebAccessUserIfLevel.all-users.all-ifs = 3
Result: Display Page 1 and Page 2 but both will be just read-only.
So in both cases, only those pages that are enabled in
saCmWebAccessReadPages will be displayed but setting the MIB to this
value will disable the write access irrespective of whatever value is
set in saCmWebAccessWritePages for that particular page.
advanced(100) - Full Access to the specified user types on specified
interfaces (Full access details for various user types are mentioned
in the Access table section of Web GUI PRD). Only the web pages enabled
for read-access using saCmWebAccessReadPages will be shown.
Default value for this MIB in various conditions will be governed by
the following table.
Interface Type Home-user Adv-user
lan 100 1 or 2*
rf-cm 1 2
mta 0 0
wan-rg 0 0
* - This will be 1 when the adv-user credentials are not defined and
the modem is online and should be 2 when adv-user credentials are
defined or the modem is offline"
::= { saCmWebAccessUserIfTypeEntry 3 }
saCmWebAccessHomeUsername OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the username for home-user.
This parameter is stored in non-vol and is blank by default.
NOTE: This should be a hidden value in SNMPGET/SNMPWALK but user
should be able to set this using SNMPSET"
::= { saCmWebAccess 3 }
saCmWebAccessHomeUserPassword OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the password for home-user.
If user's password matches the default password (meaning user has not
changed the password), a change password page comes out every time a
user connects to the web pages.
If user's password does not match the default password (meaning user
has changed it) the change password page does not show.
This parameter is stored in non-vol and is blank by default.
If the default password is blank in non-vol (after factory default for
example), it gets populated with this object's value.
NOTE: This should be a hidden value in SNMPGET/SNMPWALK but user
should be able to set this using SNMPSET"
::= { saCmWebAccess 4 }
saCmWebAccessAdvancedType OBJECT-TYPE
SYNTAX INTEGER {
plain(1),
potd(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of password for advnaced pages."
DEFVAL { 1 }
::= { saCmWebAccess 5 }
saCmWebAccessAdvancedUsername OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Username for advanced web pages.
NOTE: This should be a hidden value in SNMPGET/SNMPWALK but user
should be able to set this using SNMPSET"
DEFVAL { "admin" }
::= { saCmWebAccess 6 }
saCmWebAccessAdvancedPassword OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..40))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Password (depends on type) for advanced web pages.
If type = 1, the password is the string value.
If type = 2, the password is the 16-byte octet (hex) string
of MD5 of seed generated by the PoTD tool.
NOTE: This should be a hidden value in SNMPGET/SNMPWALK but user
should be able to set this using SNMPSET"
::= { saCmWebAccess 7 }
saCmWebAccessNoActivityTimeout OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout for a web session if no activity is present. If the timer
expires, user will be logged out of Advanced webpage. If 0, web
session will not timeout. Valid values are 0, 30-86400"
DEFVAL { 900 }
::= { saCmWebAccess 8 }
saCmWebAccessHomeUserClearPassword OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clears home-user passwords if set to true (clear=set to default).
Always returns false when read."
DEFVAL { false }
::= { saCmWebAccess 9 }
-- ======================
-- END OF WEB ACCESS TREE
-- ======================
-- =====================================
-- PUF table
-- =====================================
--
-- This table defines PUF table
--
saPUF OBJECT IDENTIFIER ::= { dpxCmMibObjects 10 }
saPUFTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaPUFEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PowerUp Frequencies scanned first."
::= { saPUF 1 }
saPUFEntry OBJECT-TYPE
SYNTAX SaPUFEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the table that specifies a single frequency."
INDEX { saPUFIndex }
::= { saPUFTable 1 }
SaPUFEntry ::= SEQUENCE {
saPUFIndex INTEGER,
saPUFRowStatus RowStatus,
saPUFFrequency Integer32,
saPUFAnnex INTEGER,
saPUFScanNow TruthValue,
saPUFScanOnNextBoot INTEGER,
saPUFScanResults INTEGER,
saPUFScanTimestamp SnmpAdminString,
saPUFScanResultsType INTEGER
}
saPUFIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the instance of this table row."
::= { saPUFEntry 1 }
saPUFRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls and reflects the status of rows in this table. Rows in this
table may be created by either the create-and-go or create-and-wait
paradigms. There is no restriction on changing values in a row of
this table while the row is active. Setting the value of this object
to active (either directly or indirectly via create-and-go) will cause
the row to be written to non-volatile storage. Changing the value of
saPUFFrequency while the row is active will also cause the
row to be written to non-volatile storage."
::= { saPUFEntry 2 }
saPUFFrequency OBJECT-TYPE
SYNTAX Integer32 (93000000..999000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Frequency in Hz"
::= { saPUFEntry 3 }
saPUFAnnex OBJECT-TYPE
SYNTAX INTEGER {
annexA(0),
annexB(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Annex mode for the frequency"
DEFVAL { 0 }
::= { saPUFEntry 4 }
saPUFScanNow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting an index of this object to true(1) causes the modem to immediately
go offline and scan for the frequency stored in saPUFFrequency.x.
The results and timestamp of the scan are stored to non-vol.
After the scan takes place the modem re-inits the CM mac and re-registers.
Conditions to run the scan:
- saPUFRowStatus.x must be set to active for a scan to take place.
- The scan will not take place if a provisioned line is offhook.
- If this mib is added to the CM config file, a scan will not take place unless
the current time from TOD server is > 360 seconds (6 minutes) from the last scan time
stored in saPUFScanTimestamp.x.
This mib object returns false(2) when read if no scan was initiated"
::= { saPUFEntry 5 }
saPUFScanOnNextBoot OBJECT-TYPE
SYNTAX INTEGER {
unset(0),
set(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting an index of this object to set(1) causes the modem to scan for
the frequency stored in saPUFFrequency.x on the next reboot and record the
results to non-vol.
After the reboot and data is recorded, the index of this object is reset back
to unset(0) .
Conditions to run a scan on Next boot:
- saPUFScanOnNextBoot.x must = set (1).
- saPUFRowStatus.x must be set to active in non-vol."
DEFVAL { 0 }
::= { saPUFEntry 6 }
saPUFScanResults OBJECT-TYPE
SYNTAX INTEGER {
notDetected(0),
detected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if RF energy was detected on the last scan.
This value is stored in non-volatile memory."
DEFVAL { 0 }
::= { saPUFEntry 7 }
saPUFScanTimestamp OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports the timestamp (YYYYMMDDHHMM) of the last scan.
This value is stored in non-volatile memory."
::= { saPUFEntry 8 }
saPUFScanResultsType OBJECT-TYPE
SYNTAX INTEGER {
notDetected(0),
qam(1),
docsisQam(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of RF energy that was detected on the last scan.
This value is stored in non-volatile memory."
DEFVAL { 0 }
::= { saPUFEntry 9 }
saPUFTrapServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the IP address of the server to send SNMP traps after running a scan.
This value is stored in non-volatile memory."
::= { saPUF 2 }
saPUFTrapControl OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enableOnEnergyDetection(1),
enableOnNoEnergyDetected(2),
enableOnFrequencyScan(3),
enableOnQamDetection(4),
enableOnDocsisQamDetection(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send a trap:
- If RF energy is detected - enableOnEnergyDetection(1),
- If RF energy is not detected - enableOnNoEnergyDetected(2),
- When a scan is run - enableOnFrequencyScan(3),
- If a QAM is detected - enableOnQamDetection(4),
- If a Docsis QAM is detected - enableOnDocsisQamDetection(5)
To disable sending traps set the MIB to disable(0),the default.
This value is written to non-volatile memory."
DEFVAL { 0 }
::= { saPUF 3 }
saPUFScanAllNow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to true(1) causes the modem to immediately go offline and
scan all the frequencies stored in the saPUFFrequency table.
Results and timestamp of the scan are stored to non-vol.
After the scan takes place the modem re-inits the CM mac and re-registers.
Conditions to run the scan:
- saPUFRowStatus.x must be set to active for a scan to take place for
that frequency.
- The scan will not take place if a provisioned line is offhook.
- If this mib is added to the CM config file, a scan will not take place
unless the current time from TOD server is > 360 seconds (6 minutes)
from the last scan time stored in saPUFScanTimestamp.x.
This mib object returns false(2)when read if no scan was initiated."
::= { saPUF 4 }
saPUFEntriesClearOnRFD OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"By Default, reset to factory default (RFD) would clear all the PUF entries to factory values.
Setting this value to false(2) would mean that the saPUF table frequencies would not be cleared upon
a factory reset. This MIB should not be cleared upon factory reset and hence in permanent non-vol. The MIB
would take effect only in configuration file, but can be read via SNMPGET or SNMPWALK."
DEFVAL { true }
::= { saPUF 5 }
-- =====================================
-- LKF table
-- =====================================
--
-- This table defines LKF table
--
saLKF OBJECT IDENTIFIER ::= { dpxCmMibObjects 11 }
saLKFTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaLKFEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Last Known Frequencies."
::= { saLKF 1 }
saLKFEntry OBJECT-TYPE
SYNTAX SaLKFEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the table that specifies a single frequency."
INDEX { saLKFIndex }
::= { saLKFTable 1 }
SaLKFEntry ::=
SEQUENCE {
saLKFIndex INTEGER,
saLKFFrequency Integer32
}
saLKFIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the instance of this table row."
::= { saLKFEntry 1 }
saLKFFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Frequency in Hz"
::= { saLKFEntry 2 }
-- ==================================
-- BEGIN saSoftwareIdentity Table
-- ====================================
saSoftwareIdentity OBJECT IDENTIFIER ::= { dpxCmMibObjects 14 }
saSoftwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaSoftwareTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Table of SW features support in the running image"
::= { saSoftwareIdentity 1 }
saSoftwareTableEntry OBJECT-TYPE
SYNTAX SaSoftwareTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the table that specifies a single reset entry."
INDEX { saSoftwareIndex }
::= { saSoftwareTable 1 }
SaSoftwareTableEntry ::= SEQUENCE {
saSoftwareIndex INTEGER,
saSoftwareBaseVersion DisplayString,
saSoftwareFeatureName DisplayString
}
saSoftwareIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the table."
::= { saSoftwareTableEntry 1 }
saSoftwareBaseVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the SoC vendor base version for the feature, if any"
::= { saSoftwareTableEntry 2 }
saSoftwareFeatureName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the features present in the software. Also provides Cisco specific compile options used"
::= { saSoftwareTableEntry 3 }
-- ===============================
-- END saSoftwareIdentity Table
-- ===============================
END