mibs/MIBS/comware/HH3C-NTP-MIB

883 lines
36 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- =================================================================
-- Copyright (c) 2004-2016 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: Network Time Protocol (NTP) Version 3, is used to synchronize
-- timekeeping among a set of distributed time servers and clients.
-- Reference:
-- Version: V1.8
-- History:
-- V1.0 <sunhaipeng>, <2003-03-19>, <initial>
-- V1.1 jinyi, 2004-12-02,
-- Fix syntax bugs and adjust format of the whole file.
-- V1.2 sunkai, 2006-03-23
-- Modified SYNTAX of hh3cNTPPeerKeyId.
-- V1.3 2010-03-05
-- Added hh3cNTPServerIP.
-- V1.4 2011-01-27
-- Added hh3cNTPSysPollSec, hh3cNTPSysClockSec. Modified hh3cNTPServerIP.
-- V1.5 2012-04-13 by huangshengliang
-- change seconds to milliseconds.
-- V1.6 2013-05-29 by niuxuning
-- Modified local clock of hh3cNTPPeerStratum.
-- V1.7 2014-03-03 by wangjianming
-- Changed the state of hh3cNTPSysPeer to obsolete.
-- Added hh3cNTPSysSrcPeer.
-- V1.8 2016-09-14 by chenzichao
-- Corrected spelling of the word 'message'.
-- =================================================================
HH3C-NTP-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Integer32, MODULE-IDENTITY, OBJECT-TYPE, Counter32, Unsigned32
FROM SNMPv2-SMI
RowStatus, TruthValue
FROM SNMPv2-TC
hh3cRhw
FROM HH3C-OID-MIB;
hh3cNTP MODULE-IDENTITY
LAST-UPDATED "200303150000Z"
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"This MIB provides mechanisms to monitor a NTP server."
REVISION "200303150000Z"
DESCRIPTION
"The initial revision of this MIB module."
::= { hh3cRhw 22 }
hh3cNTPSystemMIB OBJECT IDENTIFIER ::= { hh3cNTP 1 }
hh3cNTPSystemMIBObjects OBJECT IDENTIFIER ::= { hh3cNTPSystemMIB 1 }
hh3cNTPSysLeap OBJECT-TYPE
SYNTAX INTEGER
{
noWarning(0),
addSecond(1),
subtractSecond(2),
alarm(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Leap Indicator (LI): This is a two-bit code warning of an impending
leap second to be inserted/deleted in the last minute of the current
day, with bit 0 and bit 1, respectively, coded as follows:
00, no warning
01, last minute has 61 seconds
10, last minute has 59 seconds)
11, alarm condition (clock not synchronized)."
::= { hh3cNTPSystemMIBObjects 1 }
hh3cNTPSysStratum OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an eight-bit integer indicating the stratum level
of the local clock, with values defined as follows:
0, unspecified
1, primary reference (e.g.,, radio clock)
2-255, secondary reference (via NTP)"
::= { hh3cNTPSystemMIBObjects 2 }
hh3cNTPSysPrecision OBJECT-TYPE
SYNTAX Integer32(-20..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Precision : This is a signed integer indicating the
precision of the various clocks, in seconds to the nearest
power of two. The value must be rounded to the next larger
power of two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67ms)
power-frequency clock would be assigned the value -5 (31.25 ms),
while a 1000-Hz (1 ms) crystal-controlled clock would be assigned
the value -9 (1.95 ms)."
::= { hh3cNTPSystemMIBObjects 3 }
hh3cNTPSysRootdelay OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Root Delay : This is a signed fixed-point number indicating
the total roundtrip delay to the primary reference source
at the root of the synchronization subnet, in milliseconds. Note
that this variable can take on both positive and negative
values, depending on clock precision and skew."
::= { hh3cNTPSystemMIBObjects 4 }
hh3cNTPSysRootdispersion OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Root Dispersion : This is a signed fixed-point number
indicating the maximum error relative to the primary
reference source at the root of the synchronization
subnet, in milliseconds. Only positive values greater than
zero are possible."
::= { hh3cNTPSystemMIBObjects 5 }
hh3cNTPSysRefid OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference Clock Identifier : This is a 32-bit code
identifying the particular reference clock. In the
case of stratum 0 (unspecified) or stratum 1 (primary
reference source), this is a four-octet, left-justified,
zero-padded ASCII string.
Stratum, Code, Meaning
0, DCN, DCN routing protocol
0, TSP, TSP time protocol
1, ATOM, Atomic clock (calibrated)
1, WWVB, WWVB LF (band 5) radio
1, GOES, GOES UHF (band 9) satellite
1, WWV, WWV HF (band 7) radio"
::= { hh3cNTPSystemMIBObjects 6 }
hh3cNTPSysReftime OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference Timestamp : This is the local time, in
timestamp format, when the local clock was last
updated. If the local clock has never been synchronized,
the value is zero."
::= { hh3cNTPSystemMIBObjects 7 }
hh3cNTPSysPoll OBJECT-TYPE
SYNTAX Integer32(-20..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Poll Interval : This is a signed integer indicating
the minimum interval between transmitted messages,
in seconds as a power of two. For instance, a value
of six indicates a minimum interval of 64 seconds."
::= { hh3cNTPSystemMIBObjects 8 }
hh3cNTPSysPeer OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This is a selector identifying the current synchronization
source. Usually this will be a pointer to a structure
containing the peer variables. The special value NULL indicates
There is no currently valid synchronization source.
hh3cNTPSysPeer is replaced by hh3cNTPSysSrcPeer. Reading
hh3cNTPSysPeer might fail because the syntax value range is limited,
for example, when the synchronization source IP address is a Class C
address."
::= { hh3cNTPSystemMIBObjects 9 }
hh3cNTPSysState OBJECT-TYPE
SYNTAX INTEGER
{
noUpdateClock(0),
getfreqInfo(1),
clockBySet(2),
clockBySetAndNoFreq(3),
clockBySyns(4),
findError(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a integer indicating the state of local clock."
::= { hh3cNTPSystemMIBObjects 10 }
hh3cNTPSysOffset OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The offset of two clocks is the time difference between them, in milliseconds."
::= { hh3cNTPSystemMIBObjects 11 }
hh3cNTPSysDrift OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Real clocks exhibit some variation in skew (second derivative of
offset with time), which is called drift."
::= { hh3cNTPSystemMIBObjects 12 }
hh3cNTPSysCompliance OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a string indicating the system error."
::= { hh3cNTPSystemMIBObjects 13 }
hh3cNTPSysClock OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the current local time, in timestamp
format. Local time is derived from the hardware clock of the particular
machine and increments at intervals depending on the design used."
::= { hh3cNTPSystemMIBObjects 14 }
hh3cNTPSysStabil OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a indicating that stability of a clock is how well
it can maintain a constant frequency."
::= { hh3cNTPSystemMIBObjects 15 }
hh3cNTPSysAuthenticate OBJECT-TYPE
SYNTAX INTEGER
{
noAuthenticate(0),
authenticate(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a integer indicating that system support authentication."
::= { hh3cNTPSystemMIBObjects 16 }
hh3cNTPSysPollSec OBJECT-TYPE
SYNTAX Integer32 (2..1048576)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PollSec Interval : This is a integer indicating the minimum
interval between transmitted messages. For instance, a value of
six indicates a minimum interval of 6 seconds."
::= { hh3cNTPSystemMIBObjects 17 }
hh3cNTPSysClockSec OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the current local time, in integer format.
Local time is derived from the hardware clock of the particular
machine and increments at intervals depending on the design used."
::= { hh3cNTPSystemMIBObjects 18 }
hh3cNTPServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The NTP server ip address. It must be a unicast address,
rather than a broadcast address, a multicast address or
the IP address of the local clock. To delete a configured
NTP server ip address, please set hh3cNTPServerIP to 0."
::= { hh3cNTPSystemMIBObjects 19 }
hh3cNTPSysSrcPeer OBJECT-TYPE
SYNTAX Unsigned32(0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a selector identifying the current synchronization
source. Usually this will be a unsigned integer containing
the peer variables. The special value 0 indicates
There is no currently valid synchronization source.
This node will replace hh3cNTPSysPeer, because
its value range is unlimited, and data type is changed from
Integer32 to Unsigned32."
::= { hh3cNTPSystemMIBObjects 20 }
hh3cNTPPeerMIB OBJECT IDENTIFIER ::= { hh3cNTP 2 }
hh3cNTPPeerMIBObjects OBJECT IDENTIFIER ::= { hh3cNTPPeerMIB 1 }
hh3cNTPPeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cNTPPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides information on the peers with
which the local NTP server has associations. The peers
are also NTP servers but running on different hosts."
::= { hh3cNTPPeerMIBObjects 1 }
hh3cNTPPeerEntry OBJECT-TYPE
SYNTAX Hh3cNTPPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each peers' entry provides NTP information retrieved
from a particular peer NTP server. Each peer is
identified by a unique association identifier.
Entries are automatically created when the user
configures the NTP server to be associated with remote
peers. Similarly entries are deleted when the user
removes the peer association from the NTP server.
Entries can also be created by the management station
by setting values for the following objects:
hh3cNTPPeerRemAdr and making the hh3cNTPPeerRowStatus as
'active'. At the least, the management station has
to set a value for hh3cNTPPeerRemAdr to make the
row active."
INDEX { hh3cNTPPeerRemAdr, hh3cNTPPeerHMode }
::= { hh3cNTPPeerTable 1 }
Hh3cNTPPeerEntry ::=
SEQUENCE
{
hh3cNTPPeerConfig TruthValue,
hh3cNTPPeerAuthenable TruthValue,
hh3cNTPPeerAuthentic TruthValue,
hh3cNTPPeerRemAdr IpAddress,
hh3cNTPPeerRemPort Integer32,
hh3cNTPPeerLocAdr IpAddress,
hh3cNTPPeerLocPort Integer32,
hh3cNTPPeerLeap INTEGER,
hh3cNTPPeerHMode INTEGER,
hh3cNTPPeerStratum Integer32,
hh3cNTPPeerPPoll Integer32,
hh3cNTPPeerHPoll Integer32,
hh3cNTPPeerPrecision Integer32,
hh3cNTPPeerRootDelay OCTET STRING,
hh3cNTPPeerRootDispersion OCTET STRING,
hh3cNTPPeerRefId OCTET STRING,
hh3cNTPPeerRefTime OCTET STRING,
hh3cNTPPeerOrg OCTET STRING,
hh3cNTPPeerRec OCTET STRING,
hh3cNTPPeerXmt OCTET STRING,
hh3cNTPPeerReach Integer32,
hh3cNTPPeerValid Integer32,
hh3cNTPPeerTimer Integer32,
hh3cNTPPeerDelay OCTET STRING,
hh3cNTPPeerOffset OCTET STRING,
hh3cNTPPeerJitter OCTET STRING,
hh3cNTPPeerDispersion OCTET STRING,
hh3cNTPPeerKeyId Unsigned32,
hh3cNTPPeerFiltDelay OCTET STRING,
hh3cNTPPeerFiltOffset OCTET STRING,
hh3cNTPPeerFiltError OCTET STRING,
hh3cNTPPeerPMode INTEGER,
hh3cNTPPeerReceived Counter32,
hh3cNTPPeerSent Counter32,
hh3cNTPPeerFlash BITS,
hh3cNTPPeerRowStatus RowStatus
}
hh3cNTPPeerConfig OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a bit indicating that the association was created
from configuration information and should not be demobilized
if the peer becomes unreachable."
::= { hh3cNTPPeerEntry 1 }
hh3cNTPPeerAuthenable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a bit indicating that system support authentication."
::= { hh3cNTPPeerEntry 2 }
hh3cNTPPeerAuthentic OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a bit indicating that message pass authentication which is authentic."
::= { hh3cNTPPeerEntry 3 }
hh3cNTPPeerRemAdr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP address of the peer. When creating a new
association, a value for this object should be set
before the row is made active."
::= { hh3cNTPPeerEntry 4 }
hh3cNTPPeerRemPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UDP port number on which the peer receives NTP messages."
::= { hh3cNTPPeerEntry 5 }
hh3cNTPPeerLocAdr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the local host. Multi-homing can
be supported using this object."
::= { hh3cNTPPeerEntry 6 }
hh3cNTPPeerLocPort OBJECT-TYPE
SYNTAX Integer32(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UDP port number on which the local host receives NTP messages."
::= { hh3cNTPPeerEntry 7 }
hh3cNTPPeerLeap OBJECT-TYPE
SYNTAX INTEGER
{
noWarning(0),
addSecond(1),
subtractSecond(2),
alarm(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a two-bit code warning of an impending leap
second to be inserted in the NTP timescale. The bits
are set before 23:59 on the day of insertion and reset
after 00:00 on the following day. This causes the
number of seconds (rollover interval) in the day of
insertion to be increased or decreased by one. The two
bits are coded as below,
00, no warning
01, last minute has 61 seconds
10, last minute has 59 seconds
11, alarm condition (clock not synchronized)"
::= { hh3cNTPPeerEntry 8 }
hh3cNTPPeerHMode OBJECT-TYPE
SYNTAX INTEGER
{
unspecified (0),
symmetricActive (1),
symmetricPassive (2),
client (3),
server(4),
broadcast (5),
reservedControl (6),
reservedPrivate (7),
broadcastclient (8),
multicastclient (9)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an integer indicating the association mode,
with values coded as follows,
0, unspecified
1, symmetric active - A host operating in this mode
sends periodic messages regardless of the
reach ability state or stratum of its peer. By
operating in this mode the host announces its
willingness to synchronize and be synchronized
by the peer
2, symmetric passive - This type of association is
ordinarily created upon arrival of a message
from a peer operating in the symmetric active
mode and persists only as long as the peer is
reachable and operating at a stratum level
less than or equal to the host; otherwise, the
association is dissolved. However, the
association will always persist until at least
one message has been sent in reply. By
operating in this mode the host announces its
willingness to synchronize and be synchronized
by the peer
3, client - A host operating in this mode sends
periodic messages regardless of the
reach ability state or stratum of its peer. By
operating in this mode the host, usually a LAN
workstation, announces its willingness to be
synchronized by, but not to synchronize the peer
4, server - This type of association is ordinarily
created upon arrival of a client request message
and exists only in order to reply to that
request, after which the association is
dissolved. By operating in this mode the host,
usually a LAN time server, announces its
willingness to synchronize, but not to be
synchronized by the peer
5, broadcast - A host operating in this mode sends
periodic messages regardless of the
reach ability state or stratum of the peers.
By operating in this mode the host, usually a
LAN time server operating on a high-speed
broadcast medium, announces its willingness to
synchronize all of the peers, but not to be
synchronized by any of them
6, reserved for NTP control messages
7, reserved for private use
8, broadcastclient
9, multicastclient"
::= { hh3cNTPPeerEntry 9 }
hh3cNTPPeerStratum OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a integer indicating the stratum level
of the peer clock, with values defined as follows:
0, unspecified
1, primary reference (e.g.,, radio clock)
2-255, secondary reference (via NTP)"
::= { hh3cNTPPeerEntry 10 }
hh3cNTPPeerPPoll OBJECT-TYPE
SYNTAX Integer32(-20..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval at which the peer polls the local host."
::= { hh3cNTPPeerEntry 11 }
hh3cNTPPeerHPoll OBJECT-TYPE
SYNTAX Integer32(-20..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval at which the local host polls the peer."
::= { hh3cNTPPeerEntry 12 }
hh3cNTPPeerPrecision OBJECT-TYPE
SYNTAX Integer32(-20..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed integer indicating the precision of
the peer clock, in seconds to the nearest power of two.
The value must be rounded to the next larger power of
two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67 ms)
power-frequency clock would be assigned the value -5 (31.25 ms),
while a 1000-Hz (1 ms) crystal-controlled clock would be assigned
the value -9 (1.95 ms)."
::= { hh3cNTPPeerEntry 13 }
hh3cNTPPeerRootDelay OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed fixed-point number indicating
the total roundtrip delay to the primary reference source
at the root of the synchronization subnet, in milliseconds.
Note that this variable can take on both positive and negative
values, depending on clock precision and skew."
::= { hh3cNTPPeerEntry 14 }
hh3cNTPPeerRootDispersion OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed fixed-point number indicating
the maximum error of the peer clock relative to
the primary reference source at the root of the
synchronization subnet, in milliseconds. Only
positive values greater than zero are possible."
::= { hh3cNTPPeerEntry 15 }
hh3cNTPPeerRefId OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reference identifier of the peer.
This is a 32-bit code identifying the particular reference clock.
In the case of stratum 0 (unspecified) or stratum 1 (primary
reference source), this is a four-octet, left-justified,
zero-padded ASCII string.
Stratum, Code, Meaning
0, DCN, DCN routing protocol
0, TSP, TSP time protocol
1, ATOM, Atomic clock (calibrated)
1, WWVB, WWVB LF (band 5) radio
1, GOES, GOES UHF (band 9) satellite
1, WWV, WWV HF (band 7) radio"
::= { hh3cNTPPeerEntry 16 }
hh3cNTPPeerRefTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local time at the peer, in timestamp format,
when the local clock was last updated. If the local clock has
never been synchronized, the value is zero."
::= { hh3cNTPPeerEntry 17 }
hh3cNTPPeerOrg OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local time, in timestamp format,
at the peer when it's latest NTP message was sent.
If the peer becomes unreachable the value is set to zero"
::= { hh3cNTPPeerEntry 18 }
hh3cNTPPeerRec OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local time, in timestamp format,
when the latest NTP message from the peer arrived.
If the peer becomes unreachable the value is set to zero."
::= { hh3cNTPPeerEntry 19 }
hh3cNTPPeerXmt OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local time, in timestamp format,
at which the NTP message departed the sender."
::= { hh3cNTPPeerEntry 20 }
hh3cNTPPeerReach OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a shift register of NTP.WINDOW bits used to
determine the reach ability status of the peer,
with bits entering from the least significant (rightmost) end.
A peer is considered reachable if at least
one bit in this register is set to one"
::= { hh3cNTPPeerEntry 21 }
hh3cNTPPeerValid OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an integer counter indicating the valid samples
remaining in the filter register. It is used to
determine the reach ability state and when the
poll interval should be increased or decreased."
::= { hh3cNTPPeerEntry 22 }
hh3cNTPPeerTimer OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an integer counter used to control the
interval of transmitted NTP messages from the local host to the peer."
::= { hh3cNTPPeerEntry 23 }
hh3cNTPPeerDelay OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed fixed-point number indicating
the roundtrip delay of the peer clock relative to
the local clock over the network path between them,
in milliseconds. Note that this variable can take on
both positive and negative values, depending on
clock precision and skew-error accumulation."
::= { hh3cNTPPeerEntry 24 }
hh3cNTPPeerOffset OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed, fixed-point number indicating the offset
of the peer clock relative to the local clock, in milliseconds."
::= { hh3cNTPPeerEntry 25 }
hh3cNTPPeerJitter OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an indicating that peer of sample Variance"
::= { hh3cNTPPeerEntry 26 }
hh3cNTPPeerDispersion OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a signed fixed-point number indicating the
maximum error of the peer clock relative to the local
clock over the network path between them, in milliseconds.
Only positive values greater than zero are possible."
::= { hh3cNTPPeerEntry 27 }
hh3cNTPPeerKeyId OBJECT-TYPE
SYNTAX Unsigned32(0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an unsigned integer identifying the cryptographic
key used to generate the message-authentication code."
::= { hh3cNTPPeerEntry 28 }
hh3cNTPPeerFiltDelay OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Round-trip delay of the peer clock relative to the
local clock over the network path between them, in
milliseconds. This variable can take on both positive
and negative values, depending on clock precision
and skew-error accumulation."
::= { hh3cNTPPeerEntry 29 }
hh3cNTPPeerFiltOffset OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The offset of the peer clock relative to the local clock in milliseconds."
::= { hh3cNTPPeerEntry 30 }
hh3cNTPPeerFiltError OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum error of the peer clock relative to the
local clock over the network path between them, in
milliseconds. Only positive values greater than zero
are possible."
::= { hh3cNTPPeerEntry 31 }
hh3cNTPPeerPMode OBJECT-TYPE
SYNTAX INTEGER
{
unspecified (0),
symmetricActive (1),
symmetricPassive (2),
client (3),
server(4),
broadcast (5),
reservedControl (6),
reservedPrivate (7),
broadcastclient (8),
multicastclient (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an integer indicating the association mode,
with values coded as follows,
0, unspecified
1, symmetric active - A host operating in this mode
sends periodic messages regardless of the
reach ability state or stratum of its peer. By
operating in this mode the host announces its
willingness to synchronize and be synchronized
by the peer
2, symmetric passive - This type of association is
ordinarily created upon arrival of a message
from a peer operating in the symmetric active
mode and persists only as long as the peer is
reachable and operating at a stratum level
less than or equal to the host; otherwise, the
association is dissolved. However, the
association will always persist until at least
one message has been sent in reply. By
operating in this mode the host announces its
willingness to synchronize and be synchronized
by the peer
3, client - A host operating in this mode sends
periodic messages regardless of the
reach ability state or stratum of its peer. By
operating in this mode the host, usually a LAN
workstation, announces its willingness to be
synchronized by, but not to synchronize the peer
4, server - This type of association is ordinarily
created upon arrival of a client request message
and exists only in order to reply to that
request, after which the association is
dissolved. By operating in this mode the host,
usually a LAN time server, announces its
willingness to synchronize, but not to be
synchronized by the peer
5, broadcast - A host operating in this mode sends
periodic messages regardless of the
reach ability state or stratum of the peers.
By operating in this mode the host, usually a
LAN time server operating on a high-speed
broadcast medium, announces its willingness to
synchronize all of the peers, but not to be
synchronized by any of them
6, reserved for NTP control messages
7, reserved for private use
8, broadcastclient
9, multicastclient
When creating a new peer association, if no value
is specified for this object, it defaults to
'symmetricActive'."
::= { hh3cNTPPeerEntry 32 }
hh3cNTPPeerReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received messages."
::= { hh3cNTPPeerEntry 33 }
hh3cNTPPeerSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of send messages."
::= { hh3cNTPPeerEntry 34 }
hh3cNTPPeerFlash OBJECT-TYPE
SYNTAX BITS
{
recvRepeatMsg(0), -- received repeated message
recvremanMsg(1), -- received remanufactured message
unSynMsg(2), -- unsynchronized message
dispBeyond(3), -- the peer dispersion beyond the mark
unauthenticate(4), -- the peer unauthenticate
unSynClock(5), -- the peer clock is unsynchronized
straBeyond(6), -- the peer stratum beyond the mark
rootDispBeyond(7), -- the peer rootdispersion beyond the mark
noAuthen(8), -- the peer no authentication
refuOperate(9) -- refuse operate
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The information about the message."
::= { hh3cNTPPeerEntry 35 }
hh3cNTPPeerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status object for this row. When a management
station is creating a new row, it should set the
value for cntpPeersPeerAddress at least, before the
row can be made 'active'."
::= { hh3cNTPPeerEntry 36 }
END