mibs/MIBS/comware/HH3C-PEX-MIB

416 lines
12 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ============================================================================
-- Copyright (c) 2004-2015 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: Port Extender (PEX) information MIB
-- Reference:
-- Version: V1.2
-- History:
-- V1.0 2012-11-12 Initial version by Yang Fan
-- V1.1 2014-03-31 Changed MIB node name to PEX by zushuzhi
-- V1.2 2015-10-15 Added hh3cPexDeviceInfoTable and hh3cPexTopoTable
-- by zushuzhi
-- ============================================================================
HH3C-PEX-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
entPhysicalIndex, entPhysicalDescr
FROM ENTITY-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus, DisplayString
FROM SNMPv2-TC;
hh3cPex MODULE-IDENTITY
LAST-UPDATED "201510151129Z" -- 15th October, 2015 at 11:29 GMT
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Technologies Co., Ltd.
Haidian District Beijing P.R. China
Http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB is used to manage Port Extender (PEX)
information. This MIB is applicable to products that support PEX."
REVISION "201510151129Z"
DESCRIPTION
"Added hh3cPexDeviceInfoTable and hh3cPexTopoTable."
REVISION "201211121129Z"
DESCRIPTION
"Initial version of this MIB module."
::= { hh3cCommon 129 }
-- PEX Specification Information
hh3cPexSpecInfo OBJECT IDENTIFIER ::= { hh3cPex 1 }
hh3cPexPortMinId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest PEX port ID that can be used to uniquely identify a PEX port."
::= { hh3cPexSpecInfo 1 }
hh3cPexPortMaxId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest PEX port ID that can be used to uniquely identify a PEX port."
::= { hh3cPexSpecInfo 2 }
hh3cPexMinAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest ID that can be assigned to a port extender (PEX)."
::= { hh3cPexSpecInfo 3 }
hh3cPexMaxAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest ID that can be assigned to a PEX."
::= { hh3cPexSpecInfo 4 }
hh3cPexMaxPortPerPexPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of ports that can be bound to a PEX port."
::= { hh3cPexSpecInfo 5 }
-- PEX Information
hh3cPexTable OBJECT IDENTIFIER ::= { hh3cPex 2 }
hh3cPexPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPexPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects used to configure the PEX ports."
::= { hh3cPexTable 1 }
hh3cPexPortEntry OBJECT-TYPE
SYNTAX Hh3cPexPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX."
INDEX
{
hh3cPexPortId
}
::= { hh3cPexPortTable 1 }
Hh3cPexPortEntry ::= SEQUENCE
{
hh3cPexPortId Integer32,
hh3cPexPortAssociateId Integer32,
hh3cPexPortEntPhysicalIndex Integer32,
hh3cPexPortDescr DisplayString,
hh3cPexPortStatus INTEGER,
hh3cPexPortRowStatus RowStatus
}
hh3cPexPortId OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ID that can be used to uniquely identify a PEX port. The value range
is hh3cPexPortMinId to hh3cPexPortMaxId."
::= { hh3cPexPortEntry 1 }
hh3cPexPortAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ID assigned to a PEX. The
value range is hh3cPexMinAssociateId to hh3cPexMaxAssociateId.
The value is 0xffff if the PEX is not assigned an ID.
For a successful configuration, the ID should not be used by any
other PEX."
DEFVAL { 65535 }
::= { hh3cPexPortEntry 2 }
hh3cPexPortEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a PEX in the IRF. A value of zero
indicates that the PEX is not online."
DEFVAL { 0 }
::= { hh3cPexPortEntry 3 }
hh3cPexPortDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..79))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Description for the PEX port. The default value is
'pex-port XXXX', where 'XXXX' is hh3cPexPortId.
Writing a zero-length string to this object resets the value to the
default."
::= { hh3cPexPortEntry 4 }
hh3cPexPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
offline(1),
loading(2),
online(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the PEX.
offline: The PEX is absent or its configuration is incomplete.
loading: The PEX is loading software.
online: The PEX is operating correctly."
DEFVAL { offline }
::= { hh3cPexPortEntry 5 }
hh3cPexPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The control that allows creation and deletion of entries.
Values include createAndGo, active, and destroy.
If the row to be created or modified already exists,
an error message is returned. If the row to be deleted does not exist,
a success message is returned."
::= { hh3cPexPortEntry 6 }
-- PEX PhyPort Information
hh3cPexPhyPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPexPhyPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects used to manage physical ports
that can be bound or are already bound to a PEX port."
::= { hh3cPexTable 2 }
hh3cPexPhyPortEntry OBJECT-TYPE
SYNTAX Hh3cPexPhyPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a physical port that can be bound to or
has been bound to a PEX port."
INDEX
{
entPhysicalIndex
}
::= { hh3cPexPhyPortTable 1 }
Hh3cPexPhyPortEntry ::= SEQUENCE
{
hh3cPexPhyPortStatus INTEGER,
hh3cPexPhyPortBelongToPexPort Integer32,
hh3cPexPhyPortNeighborEntIndex Integer32
}
hh3cPexPhyPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
down(2),
blocked(3),
forwarding(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the physical port that is bound to a PEX port.
The following are status values:
unknown: The physical port is not bound to any PEX port.
down: The physical port is link down.
blocked: The physical port is blocked and cannot forward traffic.
forwarding: The physical port can forwarding traffic."
DEFVAL { unknown }
::= { hh3cPexPhyPortEntry 1 }
hh3cPexPhyPortBelongToPexPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ID of the PEX port to which the physical port belongs. The value
range is hh3cPexPortMinId to hh3cPexPortMaxId. A value of zero
indicates that the port doesn't belong to any PEX port."
DEFVAL { 0 }
::= { hh3cPexPhyPortEntry 2 }
hh3cPexPhyPortNeighborEntIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a physical port that connects the PEX to the parent
device. This value is identical to entPhysicalIndex in ENTITY-MIB.
A value of zero indicates that the physical port is not bound to any
PEX port or is not up."
::= { hh3cPexPhyPortEntry 3 }
-- PEX Topology Information
hh3cPexDeviceInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPexDeviceInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains online PEXs in the IRF system."
::= { hh3cPexTable 3 }
hh3cPexDeviceInfoEntry OBJECT-TYPE
SYNTAX Hh3cPexDeviceInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX in the IRF system. The index is the PEX
entity index."
INDEX
{
entPhysicalIndex
}
::= { hh3cPexDeviceInfoTable 1 }
Hh3cPexDeviceInfoEntry ::= SEQUENCE
{
hh3cPexDeviceStatus INTEGER,
hh3cPexDeviceAssociateId Integer32
}
hh3cPexDeviceStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the PEX.
normal: The PEX is operating correctly.
faulty: The PEX is faulty."
::= { hh3cPexDeviceInfoEntry 1 }
hh3cPexDeviceAssociateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID assigned to the PEX."
::= { hh3cPexDeviceInfoEntry 2 }
hh3cPexTopoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPexTopoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the PEX physical ports and
neighbor ports on PEXs."
::= { hh3cPexTable 4 }
hh3cPexTopoEntry OBJECT-TYPE
SYNTAX Hh3cPexTopoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a PEX link."
INDEX
{
entPhysicalIndex
}
::= { hh3cPexTopoTable 1 }
Hh3cPexTopoEntry ::= SEQUENCE
{
hh3cPexNeighborEntIndex Integer32
}
hh3cPexNeighborEntIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entity index of a PEX in the IRF system."
::= { hh3cPexTopoEntry 1 }
-- PEX Traps
hh3cPexTraps OBJECT IDENTIFIER ::= { hh3cPex 3 }
hh3cPexTrapPrefix OBJECT IDENTIFIER ::= { hh3cPexTraps 0 }
hh3cPexPortOnline NOTIFICATION-TYPE
OBJECTS
{
hh3cPexPortId,
hh3cPexPortDescr
}
STATUS current
DESCRIPTION
"An hh3cPexPortOnline trap is sent when the PEX transitions to
online state."
::= { hh3cPexTrapPrefix 1 }
hh3cPexPortOffline NOTIFICATION-TYPE
OBJECTS
{
hh3cPexPortId,
hh3cPexPortDescr
}
STATUS current
DESCRIPTION
"An hh3cPexPortOnline trap is sent when the PEX transitions to
offline state."
::= { hh3cPexTrapPrefix 2 }
hh3cPexPhyPortForwarding NOTIFICATION-TYPE
OBJECTS
{
hh3cPexEntPhysicalIndexBind,
entPhysicalDescr
}
STATUS current
DESCRIPTION
"An hh3cPexPhyPortForwarding trap is sent when the PEX physical port
transitions to forwarding state."
::= { hh3cPexTrapPrefix 3 }
hh3cPexPhyPortBlocked NOTIFICATION-TYPE
OBJECTS
{
hh3cPexEntPhysicalIndexBind,
entPhysicalDescr
}
STATUS current
DESCRIPTION
"An hh3cPexPhyPortBlocked trap is sent when the PEX physical port
transitions from forwarding state to blocked state."
::= { hh3cPexTrapPrefix 4 }
hh3cPexTrapObjects OBJECT IDENTIFIER ::= { hh3cPex 4 }
hh3cPexEntPhysicalIndexBind OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { hh3cPexTrapObjects 1 }
END