mibs/MIBS/comware/HH3C-RMON-EXT-MIB

473 lines
20 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ==================================================================
-- Copyright (C) 2002 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: This file describes the hh3c MIB implementation of perormance
-- Reference: the content of this file include part description from RFC1757
-- Version: V2.0
-- History:
-- v1.0 Created by Qizhenglin, 2002.8.15
-- v1.1 2004-7-6 xiejianping
-- merge HH3C-RMON-EXT-MIB to HH3C-LswPERFORMANCE-MIB and change
-- module name from HH3C-LswPERFORMANCE-MIB to HH3C-RMON-EXT-MIB
-- V2.0 2004-10-12 updated by gaolong
-- Import from SNMPv2-SMI instead from RFC-1212
-- Import hh3cInternetProtocol, rmonExtend instead define them in the MIB.
-- Change ACCESS to MAX-ACCESS.
-- Change value of STATUS from mandatory to current.
-- Remove value range from PriAlarmEntry definition.
-- Adjust text format of the whole file.
-- ==================================================================
-- ==================================================================
--
-- Varibles and types be imported
--
-- ==================================================================
HH3C-RMON-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
OwnerString
FROM IF-MIB
trapDestEntry, trapDestIndex
FROM RMON2-MIB
EntryStatus
FROM RMON-MIB
hh3crmonExtend
FROM HH3C-OID-MIB;
-- ==================================================================
--
-- ======================= definition begin =========================
--
-- ==================================================================
hh3cperformance MODULE-IDENTITY
LAST-UPDATED "200303150000Z" -- March 19, 2003 at 16:05 GMT
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
" "
REVISION "200303150000Z" -- March 19, 2003 at 16:06 GMT
DESCRIPTION
"The initial revision of this MIB module."
::= { hh3crmonExtend 4 }
hh3cprialarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPriAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of alarm entries."
::= { hh3cperformance 1 }
hh3cprialarmEntry OBJECT-TYPE
SYNTAX Hh3cPriAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a periodic checking
for alarm conditions. For example, an instance of the
alarmValue object might be named alarmValue.8"
INDEX { hh3cprialarmIndex }
::= { hh3cprialarmTable 1 }
Hh3cPriAlarmEntry ::= SEQUENCE {
hh3cprialarmIndex INTEGER,
hh3cprialarmInterval INTEGER,
hh3cprialarmVariable DisplayString,
hh3cprialarmSympol DisplayString,
hh3cprialarmSampleType INTEGER,
hh3cprialarmValue INTEGER,
hh3cprialarmStartupAlarm INTEGER,
hh3cprialarmRisingThreshold INTEGER,
hh3cprialarmFallingThreshold INTEGER,
hh3cprialarmRisingEventIndex INTEGER,
hh3cprialarmFallingEventIndex INTEGER,
hh3cprialarmStatCycle INTEGER,
hh3cprialarmStatType INTEGER,
hh3cprialarmOwner OwnerString,
hh3cprialarmStatus EntryStatus
}
hh3cprialarmIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device."
::= { hh3cprialarmEntry 1 }
hh3cprialarmInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 2 }
hh3cprialarmVariable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1 primitive
type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
Gauge, or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
probe must only grant write access to this object in
those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable name is
not available in the selected MIB view, a badValue error
must be returned. If at any time the variable name of
an established alarmEntry is no longer available in the
selected MIB view, the probe must change the status of
this alarmEntry to invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 3 }
hh3cprialarmSympol OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { hh3cprialarmEntry 4 }
hh3cprialarmSampleType OBJECT-TYPE
SYNTAX INTEGER {
absoluteValue(1),
deltaValue(2),
speedValue(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 5 }
hh3cprialarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the statistic during the last sampling
period. For example, if the sample type is deltaValue,
this value will be the difference between the samples
at the beginning and end of the period. If the sample
type is absoluteValue, this value will be the sampled
value at the end of the period.
This is the value that is compared with the rising and
falling thresholds.
The value during the current sampling period is not
made available until the period is completed and will
remain available until the next period completes."
::= { hh3cprialarmEntry 6 }
hh3cprialarmStartupAlarm OBJECT-TYPE
SYNTAX INTEGER {
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a single
rising alarm will be generated. If the first sample
after this entry becomes valid is less than or equal
to the fallingThreshold and alarmStartupAlarm is equal
to fallingAlarm(2) or risingOrFallingAlarm(3), then a
single falling alarm will be generated.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 7 }
hh3cprialarmRisingThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is greater than or
equal to this threshold and the associated
alarmStartupAlarm is equal to risingAlarm(1) or
risingOrFallingAlarm(3).
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 8 }
hh3cprialarmFallingThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold,
and the value at the last sampling interval was greater than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is less than or
equal to this threshold and the associated
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3).
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 9 }
hh3cprialarmRisingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 10 }
hh3cprialarmFallingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { hh3cprialarmEntry 11 }
hh3cprialarmStatCycle OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { hh3cprialarmEntry 12 }
hh3cprialarmStatType OBJECT-TYPE
SYNTAX INTEGER{
forever(1),
during(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { hh3cprialarmEntry 13 }
hh3cprialarmOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { hh3cprialarmEntry 14 }
hh3cprialarmStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this alarm entry."
::= { hh3cprialarmEntry 15 }
hh3crmonEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3crmonEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of enable rmon entries."
::= { hh3crmonExtend 5 }
hh3crmonEnableEntry OBJECT-TYPE
SYNTAX Hh3crmonEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a hh3crmonEnableTable"
INDEX { hh3crmonEnableIfIndex }
::= { hh3crmonEnableTable 1 }
Hh3crmonEnableEntry ::= SEQUENCE {
hh3crmonEnableIfIndex INTEGER,
hh3crmonEnableStatus INTEGER
}
hh3crmonEnableIfIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify an interface to enable rmon."
::= { hh3crmonEnableEntry 1 }
hh3crmonEnableStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify an interface to enable rmon."
::= { hh3crmonEnableEntry 2 }
hh3cTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the trap destination Extend Table for providing, via SNMP,
the capability of configure a trap dest."
::= { hh3crmonExtend 6 }
hh3cTrapDestEntry OBJECT-TYPE
SYNTAX Hh3cTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the hh3cTrapDestTable."
AUGMENTS { trapDestEntry }
::= { hh3cTrapDestTable 1 }
Hh3cTrapDestEntry ::=
SEQUENCE {
hh3cTrapDestVersion INTEGER
}
hh3cTrapDestVersion OBJECT-TYPE
SYNTAX INTEGER {
snmpv1(1),
snmpv2(2),
snmpv3andauthen(3),
snmpv3andnoauthen(4),
snmpv3andpriv(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The version for trap destination.
This object may not be modified if the associated
trapDestStatus object is equal to active(1)."
DEFVAL { snmpv1 }
::= { hh3cTrapDestEntry 1 }
-- extend from Remote Network Monitoring Traps
hh3crmonExtendEventsV2 OBJECT-IDENTITY
STATUS current
DESCRIPTION "Definition point for pri RMON notifications."
::= { hh3crmonExtend 0 }
hh3cpririsingAlarm NOTIFICATION-TYPE
OBJECTS { hh3cprialarmIndex, hh3cprialarmSympol, hh3cprialarmSampleType,
hh3cprialarmValue, hh3cprialarmRisingThreshold }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps."
::= { hh3crmonExtendEventsV2 1 }
hh3cprifallingAlarm NOTIFICATION-TYPE
OBJECTS { hh3cprialarmIndex, hh3cprialarmSympol, hh3cprialarmSampleType,
hh3cprialarmValue, hh3cprialarmFallingThreshold }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps."
::= { hh3crmonExtendEventsV2 2 }
END