BROADCOM-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
-- Copyright Broadcom Corporation (2003-2007) All rights reserved.
-- This SNMP Management Information Specification
-- embodies Broadcom Corporation's confidential and proprietary
-- intellectual property. Broadcom Corporation retains all title
-- and ownership in the Specification including any revisions.
-- This Specification is supplied "AS IS", Broadcom Corporation
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
fastPath FROM BROADCOM-REF-MIB
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
fastPathpowerEthernetMIB MODULE-IDENTITY
LAST-UPDATED "200708191200Z" -- 17 Aug 2007 12:00:00 GMT
ORGANIZATION "Broadcom Corporation"
CONTACT-INFO
" Customer Support
Postal: Broadcom Corporation
100 Perimeter Park Dr., Suite H
Morrisville, NC 27560
Tel: +1 919 865 2700"
DESCRIPTION
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
Interfaces and Hub MIB Working Group for managing Power Source
Equipment (PSE). The objects in this MIB are intended to provide
additional objects for reporting information available to the hardware
on this platform which are not represented in the draft MIB."
-- Revision history.
REVISION
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT
DESCRIPTION
"PoE support for BCM59101 added."
REVISION
"200705230000Z" -- 23 May 2007 12:00:00 GMT
DESCRIPTION
"Broadcom branding related changes."
REVISION
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT
DESCRIPTION
"Initial revision."
::= { fastPath 15 }
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
agentPethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-port information and configuration objects relating
to the power status of each port."
::= { agentPethObjects 1 }
agentPethPsePortEntry OBJECT-TYPE
SYNTAX AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified port."
AUGMENTS { pethPsePortEntry }
::= { agentPethPsePortTable 1 }
AgentPethPsePortEntry ::= SEQUENCE {
agentPethPowerLimit
Gauge32,
agentPethOutputPower
Gauge32,
agentPethOutputCurrent
Gauge32,
agentPethOutputVolts
Gauge32,
agentPethTemperature
Gauge32,
agentPethPowerLimitType
INTEGER,
agentPethHighPowerEnable
TruthValue,
agentPethPowerDetectionType
INTEGER,
agentPethFaultStatus
INTEGER,
agentPethPortReset
INTEGER
}
agentPethPowerLimit OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured maximum power this port can provide to an
attached device measured in Milliwatts."
::= { agentPethPsePortEntry 1 }
agentPethOutputPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power this port is supplying to an attached device measured
in Milliwatts."
::= { agentPethPsePortEntry 2 }
agentPethOutputCurrent OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliamps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current this port is supplying to an attached device measured
in Milliamps."
::= { agentPethPsePortEntry 3 }
agentPethOutputVolts OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage this port is supplying to an attached device measured
in Volts."
::= { agentPethPsePortEntry 4 }
agentPethTemperature OBJECT-TYPE
SYNTAX Gauge32
UNITS "DEGREES"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature measured at this port of the PoE Controller. It is
measured in degree celcius."
::= { agentPethPsePortEntry 5 }
agentPethPowerLimitType OBJECT-TYPE
SYNTAX INTEGER {
dot3af(1),
user(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the maximum power that a port can deliver
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit"
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
::= { agentPethPsePortEntry 6 }
agentPethHighPowerEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true (1) The PSE port can deliver power up to 32Watts.
false(2) The PSE port can deliver power up to 18Watts"
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPsePortEntry 7 }
agentPethPowerDetectionType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
legacy(1),
fourPtdot3afonly(2),
fourPtdot3afandlegacy(3),
twoPtdot3afonly(4),
twoPtdot3afandlegacy(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes PD detection mechanism performed by the PSE port.
A value of none(0) means no detection is done.
A value of legacy(1) means only legacy capacitive detection scheme is
used.
A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme
is used.
A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme
is used.
A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
The value 'none' can not be forcibly set by the administrator."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
::= { agentPethPsePortEntry 8 }
agentPethFaultStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
mpsAbsent(1),
short(2),
overload(3),
powerDenied(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the error description when the pse port is in fault status.
A value of none(0) specifies that the pse port is not in any error state.
A value of mpsAbsent(1) specifies that the pse port has detected and absence
of main power supply.
A value of short(2) specifies that the pse port has detected a short circuit
condition.
A value of overload(3) specifies that the pd connected to the pse port had tried
to draw more power than permissible by the hardware.
A value of powerDenied(4) specifies that the pse port has been denied power
because of shortage of power or due to administrative action."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
::= { agentPethPsePortEntry 9 }
agentPethPortReset OBJECT-TYPE
SYNTAX INTEGER {
none(0),
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of reset(1) is used to move the pse port dot3af state to idle. A
read on this object will always return the value none(0). The value none(0)
can not be forcibly set by the administrtor."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
::= { agentPethPsePortEntry 10 }
-- Main objects
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
agentPethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { agentPethMainPseObjects 1 }
agentPethMainPseEntry OBJECT-TYPE
SYNTAX AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main
power of a PSE. "
AUGMENTS { pethMainPseEntry }
::= { agentPethMainPseTable 1 }
AgentPethMainPseEntry ::= SEQUENCE {
agentPethMainPseLegacy
TruthValue
}
agentPethMainPseLegacy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Legacy device detection. The
value true(1) means legacy devices are detected; the
value false(2) means legacy devices are not detected."
::= { agentPethMainPseEntry 1 }
agentPethPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-unit information and configuration objects relating
to the power configurtion for the entire pse unit."
::= { agentPethObjects 3 }
agentPethPseEntry OBJECT-TYPE
SYNTAX AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified pse unit."
AUGMENTS { pethMainPseEntry }
::= { agentPethPseTable 1 }
AgentPethPseEntry ::= SEQUENCE {
agentPethPsePowerManagementMode
INTEGER,
agentPethPseAutoResetEnable
TruthValue
}
agentPethPsePowerManagementMode OBJECT-TYPE
SYNTAX INTEGER {
none(0),
dynamic(1),
static(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the power management algorithm used by the pse
to deliver power to the requesting PDsthat a pds.
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit"
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPseEntry 1 }
agentPethPseAutoResetEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true (1) The PSE port is reset with out administrator intervention whenver a
fault condition occurs.
false(2) Administrator has to reset the pse port whenver a fault condition
is detected."
::= { agentPethPseEntry 2 }