mibs/MIBS/eltexmes23xx/ELTEX-MES-HWENVIROMENT-MIB

137 lines
4.2 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ELTEX-MES-HWENVIROMENT-MIB DEFINITIONS ::= BEGIN
-- Title: Eltex MES Hardware enviroment definition
-- Version: 1.3
-- Date: 27-Jul-2018
IMPORTS
eltMes FROM ELTEX-MES
OBJECT-TYPE FROM SNMPv2-SMI
RlEnvMonState, rlEnvMonFanStatusEntry FROM RADLAN-HWENVIROMENT;
eltMesEnv MODULE-IDENTITY
LAST-UPDATED "201807270000Z"
ORGANIZATION "Eltex Enterprise Co, Ltd."
CONTACT-INFO "www.eltex.nsk.ru"
DESCRIPTION
"This private MIB module contains Eltex's hardware enviroment definition."
REVISION "201807270000Z"
DESCRIPTION
"Added eltEnvResetButtonMode scalar."
REVISION "201710110000Z"
DESCRIPTION
"Added Eltex's hardware enviroment definition."
REVISION "201506110000Z"
DESCRIPTION
"Initial revision."
::= { eltMes 11 }
--------------------------------------------------------------------------------
-- eltEnvMonBatteryStatusTable
--------------------------------------------------------------------------------
eltEnvMonBatteryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltEnvMonBatteryStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of battery status maintained by the environmental monitor
card."
::= { eltMesEnv 1 }
eltEnvMonBatteryStatusEntry OBJECT-TYPE
SYNTAX EltEnvMonBatteryStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the battery status table, representing the status of
the associated battery maintained by the environmental monitor."
INDEX { eltEnvMonBatteryStatusIndex }
::= { eltEnvMonBatteryStatusTable 1 }
EltEnvMonBatteryStatusEntry ::= SEQUENCE {
eltEnvMonBatteryStatusIndex INTEGER,
eltEnvMonBatteryState RlEnvMonState,
eltEnvMonBatteryStatusCharge INTEGER
}
eltEnvMonBatteryStatusIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the battery being instrumented. This index is for SNMP
purposes only, and has no intrinsic meaning."
::= { eltEnvMonBatteryStatusEntry 1 }
eltEnvMonBatteryState OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the battery being instrumented."
::= { eltEnvMonBatteryStatusEntry 2 }
eltEnvMonBatteryStatusCharge OBJECT-TYPE
SYNTAX INTEGER(0..100 | 255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remaining percentage of battery charge. Value of 255 means that this
parameter is undefined due to battery not supporting this feature or
because it cannot be obtained in current state."
::= { eltEnvMonBatteryStatusEntry 3 }
--
-- eltEnvResetButtonMode
--
eltEnvResetButtonMode OBJECT-TYPE
SYNTAX INTEGER {
enable(0),
disable(1),
reset-only(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of reset button: 0 - Enable, 1 - disable, 2 - reset-only mode"
DEFVAL { enable }
::= { eltMesEnv 2 }
--
-- eltEnvMonFanStatusTable
--
eltEnvMonFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of fan status maintained by the environmental monitor"
::= { eltMesEnv 3 }
eltEnvMonFanStatusEntry OBJECT-TYPE
SYNTAX EltEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments existing RADLAN table rlEnvMonFanStatusTable"
AUGMENTS { rlEnvMonFanStatusEntry }
::= { eltEnvMonFanStatusTable 1 }
EltEnvMonFanStatusEntry ::= SEQUENCE {
eltEnvMonFanSpeed INTEGER
}
eltEnvMonFanSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter represents the speed of the fan in RPM"
::= { eltEnvMonFanStatusEntry 1 }