mibs/MIBS/enlogic/ENLOGIC-PDU-MIB

5192 lines
146 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ENLOGIC-PDU-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI
enterprises, Integer32, Unsigned32, IpAddress FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
TEXTUAL-CONVENTION, DisplayString, MacAddress, TruthValue FROM SNMPv2-TC
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
sysContact, sysName, sysLocation FROM RFC1213-MIB;
enlogic MODULE-IDENTITY
LAST-UPDATED "201506180000Z" -- June 18, 2015
ORGANIZATION "Enlogic"
CONTACT-INFO ""
DESCRIPTION "This MIB describes the SNMP functions of the Enlogic PDU."
REVISION "201410280000Z" -- October 28, 2014
DESCRIPTION "
1. Add Smart Cabinet related MIB nodes.
"
REVISION "201406050000Z" -- June 5, 2014
DESCRIPTION "
1. Add new trap named espNetworkUp for ES PDU.
"
REVISION "201404300000Z" -- April 30, 2014
DESCRIPTION "
1. Modify description of MIB node pduInputPhaseStatusCurrentState, pduInputPhaseStatusCurrent, pduInputPhaseStatusVoltage, pduInputPhaseStatusActivePower,
pduInputPhaseStatusApparentPower and pduInputPhaseStatusPowerFactor.
"
REVISION "201306050000Z" -- June 5, 2013
DESCRIPTION "
1. Change node pduExternalSensorStatusAisle to be writable.
"
REVISION "201305310000Z" -- May 31, 2013
DESCRIPTION "
1. Add MIB node for daisy chain state.
"
REVISION "201303280000Z" -- March 28, 2013
DESCRIPTION "
1. Add one more attribute for all trap oids indicating pdu idx in case of daisy chain.
2. Add one more MIB node in order to reset network management card
"
REVISION "201303210000Z" -- March 21, 2013
DESCRIPTION "
1. Add MIB node for external sensor unique identifier.
2. Add MIB node for external sensor readings with higher Pricision.
"
REVISION "201301240000Z" -- January 24, 2013
DESCRIPTION "
1. change external sensor name doorContact to doorSwitch
"
REVISION "201301060000Z" -- January 6, 2013
DESCRIPTION "
1. change the enum value definition of external sensor threshold setting
2. Add a new node to enable/disable SSH connection
3. Add one more external sensor unit
"
REVISION "201212280000Z" -- December 28, 2012
DESCRIPTION "
1. Add one more node to enable/disable sensor
"
REVISION "201209280000Z" -- September 28, 2012
DESCRIPTION "
1. Added additional indexes.
"
REVISION "201209250000Z" -- September 25, 2012
DESCRIPTION "
1. Changed descriptions for status readings.
"
REVISION "201209180000Z" -- September 18, 2012
DESCRIPTION "
1. Changed descriptions for alarm thresholds.
2. Renamed pduOutletMeteredStatusEnergy to pduOutletMeteredStatusResettableEnergy.
3. Added pduUnitConfigOutletPeakPowerReset
"
REVISION "201209130000Z" -- September 13, 2012
DESCRIPTION "
1. Changed SYNTAX of pduUnitConfigUpperWarningThreshold SEQUENCE to Unsigned32
2. Changed SYNTAX of pduOutletSwitchedStateOnStartup to Integer32
3. Changed SYNTAX of pduServerPingEnabled to TruthValue
4. Added trapsInformationIndex to SEQUENCE of TrapsInformationEntry
"
::= { enterprises 38446 }
pdu OBJECT IDENTIFIER ::= { enlogic 1 }
pduNamePlate OBJECT IDENTIFIER ::= { pdu 1 }
pduUnit OBJECT IDENTIFIER ::= { pdu 2 }
pduInputPhase OBJECT IDENTIFIER ::= { pdu 3 }
pduCircuitBreaker OBJECT IDENTIFIER ::= { pdu 4 }
pduOutlet OBJECT IDENTIFIER ::= { pdu 5 }
pduExternalSensor OBJECT IDENTIFIER ::= { pdu 6 }
pduServerPing OBJECT IDENTIFIER ::= { pdu 7 }
pduSmartCabinet OBJECT IDENTIFIER ::= { pdu 8 }
pduTraps OBJECT IDENTIFIER ::= { pdu 9 }
-- Start pduNamePlate
pduNamePlateTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of PDUs"
::= { pduNamePlate 1 }
-- pduNamePlateTable
pduNamePlateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU nameplate data"
::= { pduNamePlate 2 }
pduNamePlateEntry OBJECT-TYPE
SYNTAX PduNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Nameplate data from the PDU being queried. The numbers of entries equals the value of pduNamePlateTableSize."
INDEX { pduNamePlateIndex }
::= { pduNamePlateTable 1 }
PduNamePlateEntry ::= SEQUENCE {
pduNamePlateIndex
Integer32,
pduNamePlateName
DisplayString,
pduNamePlateLocation
DisplayString,
pduNamePlateInetAddressType
InetAddressType,
pduNamePlateIPAddress
InetAddress,
pduNamePlateInetNetMask
InetAddress,
pduNamePlateInetGateway
InetAddress,
pduNamePlateMACAddress
MacAddress,
pduNamePlateUTCTimeOffset
DisplayString,
pduNamePlateModelNumber
DisplayString,
pduNamePlateSerialNumber
DisplayString,
pduNamePlateDateofManufacture
DisplayString,
pduNamePlateFirmwareVersion
DisplayString,
pduNamePlateFirmwareVersionTimeStamp
DisplayString,
pduNamePlateType
INTEGER
}
pduNamePlateIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU nameplate table entry"
::= { pduNamePlateEntry 1 }
pduNamePlateName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { pduNamePlateEntry 2 }
pduNamePlateLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the location of PDU"
::= { pduNamePlateEntry 3 }
pduNamePlateInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of address format"
::= { pduNamePlateEntry 4 }
pduNamePlateIPAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address. A value of 0.0.0.0 indicates an error or an unset option"
::= { pduNamePlateEntry 5 }
pduNamePlateInetNetMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current netmask. A value of 0.0.0.0 indiates an error or an unset option"
::= { pduNamePlateEntry 6 }
pduNamePlateInetGateway OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current gateway. A value of 0.0.0.0 indicates an error or an unset option"
::= { pduNamePlateEntry 7 }
pduNamePlateMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The assigned MAC address for the PDU"
::= { pduNamePlateEntry 8 }
pduNamePlateUTCTimeOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The difference in hours and minutes from Coordinated Universal
Time(UTC) for the time used in a particular time zone"
::= { pduNamePlateEntry 9 }
pduNamePlateModelNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU model number"
::= { pduNamePlateEntry 10 }
pduNamePlateSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU serial number"
::= { pduNamePlateEntry 11 }
pduNamePlateDateofManufacture OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date the PDU was manufactured in mm/dd/yyyy format"
::= { pduNamePlateEntry 12 }
pduNamePlateFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU firmware version"
::= { pduNamePlateEntry 13 }
pduNamePlateFirmwareVersionTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of when the PDU firmware was last updated"
::= { pduNamePlateEntry 14 }
pduNamePlateType OBJECT-TYPE
SYNTAX INTEGER {
pdu (0),
inlineMeter (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Unit, PDU or Inline Meter"
::= { pduNamePlateEntry 15 }
-- Start pduUnit
pduUnitTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of units."
::= { pduUnit 1 }
pduUnitConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduUnitConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU configuration data"
::= { pduUnit 2 }
pduUnitConfigEntry OBJECT-TYPE
SYNTAX PduUnitConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration data from the PDU being queried. The number of entries equals the value of pduUnitTableSize"
INDEX { pduUnitConfigIndex }
::= { pduUnitConfigTable 1 }
PduUnitConfigEntry ::= SEQUENCE {
pduUnitConfigIndex
Integer32,
pduUnitConfigName
DisplayString,
pduUnitConfigLocation
DisplayString,
pduUnitConfigDisplayOrientation
INTEGER,
pduUnitConfigColdstartDelay
Unsigned32,
pduUnitConfigGlobalOutletStateOnStartup
INTEGER,
pduUnitConfigLowerCriticalThreshold
Unsigned32,
pduUnitConfigLowerWarningThreshold
Unsigned32,
pduUnitConfigUpperCriticalThreshold
Unsigned32,
pduUnitConfigUpperWarningThreshold
Unsigned32,
pduUnitConfigAlarmResetThreshold
Unsigned32,
pduUnitConfigAlarmStateChangeDelay
Unsigned32,
pduUnitConfigEnabledThresholds
BITS,
pduUnitConfigPeakPowerReset
INTEGER,
pduUnitConfigEnergyReset
INTEGER,
pduUnitConfigOutletPeakPowerReset
INTEGER,
pduUnitConfigOutletEnergyReset
INTEGER,
pduUnitConfigUsb
INTEGER,
pduUnitConfigSsh
INTEGER,
pduUnitConfigResetNetworkManagementCard
INTEGER,
pduUnitConfigDaisyChainState
INTEGER
}
pduUnitConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Unit Config Entry"
::= { pduUnitConfigEntry 1 }
pduUnitConfigName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { pduUnitConfigEntry 2 }
pduUnitConfigLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the location of the PDU"
::= { pduUnitConfigEntry 3 }
pduUnitConfigDisplayOrientation OBJECT-TYPE
SYNTAX INTEGER {
displayNormal (1),
displayReverse (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the intended physical orientation of the oLED display
displayNormal (1) indicates normal orientation.
displayReverse (2) indicates upside down orientation"
::= { pduUnitConfigEntry 4 }
pduUnitConfigColdstartDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time, specified in seconds, between when power
is provided to the PDU and when the PDU start providing basic master
power to the outlets"
::= { pduUnitConfigEntry 5 }
pduUnitConfigGlobalOutletStateOnStartup OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
lastKnownState (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The outlet state on device startup; applies to all outlets
unless overridden at the outlet level"
::= { pduUnitConfigEntry 6 }
pduUnitConfigLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical unit active power alarm threshold measured in Watts"
::= { pduUnitConfigEntry 7 }
pduUnitConfigLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts"
::= { pduUnitConfigEntry 8 }
pduUnitConfigUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical unit active power alarm threshold measured in Watts"
::= { pduUnitConfigEntry 9 }
pduUnitConfigUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts"
::= { pduUnitConfigEntry 10 }
pduUnitConfigAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for deassertions in Watts"
::= { pduUnitConfigEntry 11 }
pduUnitConfigAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported."
::= { pduUnitConfigEntry 12 }
pduUnitConfigEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which alarm thresholds are enabled"
::= { pduUnitConfigEntry 13 }
pduUnitConfigPeakPowerReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will
do nothing and return the noOperation(1) value. "
::= { pduUnitConfigEntry 14 }
pduUnitConfigEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2),
notSupported (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not support this feature will respond to this OID with a
value of notSupported (3). Attempts to set this OID in these models will fail. "
::= { pduUnitConfigEntry 15 }
pduUnitConfigOutletPeakPowerReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2),
notSupported (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the outlet peak power meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not support this feature will respond to this OID with a
value of notSupported (3). Attempts to set this OID in these models will fail. "
::= { pduUnitConfigEntry 16 }
pduUnitConfigOutletEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2),
notSupported (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the outlet energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not support this feature will respond to this OID with a
value of notSupported (3). Attempts to set this OID in these models will fail. "
::= { pduUnitConfigEntry 17 }
pduUnitConfigUsb OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port."
::= { pduUnitConfigEntry 18 }
pduUnitConfigSsh OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection."
::= { pduUnitConfigEntry 19 }
pduUnitConfigResetNetworkManagementCard OBJECT-TYPE
SYNTAX INTEGER {
noOperation (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC."
::= { pduUnitConfigEntry 20 }
pduUnitConfigDaisyChainState OBJECT-TYPE
SYNTAX INTEGER {
daisychain (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to daisychain(0) will enable daisychain mode."
::= { pduUnitConfigEntry 21 }
pduUnitPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduUnitPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU properties"
::= { pduUnit 3 }
pduUnitPropertiesEntry OBJECT-TYPE
SYNTAX PduUnitPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unit properties entry containing objects for a particular unit."
INDEX { pduUnitPropertiesIndex }
::= { pduUnitPropertiesTable 1 }
PduUnitPropertiesEntry ::= SEQUENCE {
pduUnitPropertiesIndex
Integer32,
pduUnitPropertiesName
DisplayString,
pduUnitPropertiesOutletCount
Integer32,
pduUnitPropertiesSwitchedOutletCount
Integer32,
pduUnitPropertiesMeteredOutletCount
Integer32,
pduUnitPropertiesInputPhaseCount
Integer32,
pduUnitPropertiesCircuitBreakerCount
Integer32,
pduUnitPropertiesMaxExternalSensorCount
Integer32,
pduUnitPropertiesConnExternalSensorCount
Integer32,
pduUnitPropertiesRatedVoltage
DisplayString,
pduUnitPropertiesRatedMaxCurrent
DisplayString,
pduUnitPropertiesRatedFrequency
DisplayString,
pduUnitPropertiesRatedPower
DisplayString,
pduUnitPropertiesOrientation
INTEGER,
pduUnitPropertiesOutletLayout
INTEGER,
pduUnitPropertiesDaisyChainMemberType
INTEGER,
pduUnitPropertiesServerCount
Integer32
}
pduUnitPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU properties table entry"
::= { pduUnitPropertiesEntry 1 }
pduUnitPropertiesName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { pduUnitPropertiesEntry 2 }
pduUnitPropertiesOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of outlets on the PDU"
::= { pduUnitPropertiesEntry 3 }
pduUnitPropertiesSwitchedOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of switched outlets on the PDU"
::= { pduUnitPropertiesEntry 4 }
pduUnitPropertiesMeteredOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of metered outlets on the PDU"
::= { pduUnitPropertiesEntry 5 }
pduUnitPropertiesInputPhaseCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of phases on the PDU"
::= { pduUnitPropertiesEntry 6 }
pduUnitPropertiesCircuitBreakerCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of circuit breaker on the PDU"
::= { pduUnitPropertiesEntry 7 }
pduUnitPropertiesMaxExternalSensorCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of external sensors that can be connected to the PDU"
::= { pduUnitPropertiesEntry 8 }
pduUnitPropertiesConnExternalSensorCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of external sensors connected to the PDU"
::= { pduUnitPropertiesEntry 9 }
pduUnitPropertiesRatedVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU voltage rating in Volts"
::= { pduUnitPropertiesEntry 10 }
pduUnitPropertiesRatedMaxCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU current rating in Amps"
::= { pduUnitPropertiesEntry 11 }
pduUnitPropertiesRatedFrequency OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU frequency rating in Hz"
::= { pduUnitPropertiesEntry 12 }
pduUnitPropertiesRatedPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU VA (VoltAmps) rating."
::= { pduUnitPropertiesEntry 13 }
pduUnitPropertiesOrientation OBJECT-TYPE
SYNTAX INTEGER {
horizontal (1),
vertical (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU orientation "
::= { pduUnitPropertiesEntry 14 }
pduUnitPropertiesOutletLayout OBJECT-TYPE
SYNTAX INTEGER {
seqPhaseToNuetral (1),
seqPhaseToPhase (2),
seqPhToNeu21PhToPh (3),
seqPhToPhGrouped (4),
seqPhToNGrouped (5),
seqPToN1516PToPGrouped (6),
seqPhToPh2xGrouped (7),
seqPhToN2xGrouped (8),
seqNotApplicable (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
seqPhaseToPhase(2) indicates outlet layout as follows:
1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
seqPhToPhGrouped(4) indicates outlet layout as follows:
This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1.
seqPhToNGrouped(5) indicates outlet layout as follows:
This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.
seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.
seqPhToPh2xGrouped(7) indicates outlet layout as follows:
This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
Group 4:2-3, Group 5:3-1, Group 6:3-1.
seqPhToN2xGrouped(8) indicates outlet layout as follows:
This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
Group 4:2-N, Group 5:3-N, Group 6:3-N.
seqNotApplicable(9):"
::= { pduUnitPropertiesEntry 15 }
pduUnitPropertiesDaisyChainMemberType OBJECT-TYPE
SYNTAX INTEGER {
standalone (1),
parent (2),
child (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The daisy-chain member type"
::= { pduUnitPropertiesEntry 16 }
pduUnitPropertiesServerCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of servers"
::= { pduUnitPropertiesEntry 17 }
pduUnitStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduUnitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU status information"
::= { pduUnit 4 }
pduUnitStatusEntry OBJECT-TYPE
SYNTAX PduUnitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status information from the PDU being queried"
INDEX { pduUnitStatusIndex }
::= { pduUnitStatusTable 1 }
PduUnitStatusEntry ::= SEQUENCE {
pduUnitStatusIndex
Integer32,
pduUnitStatusName
DisplayString,
pduUnitStatusLoadState
INTEGER,
pduUnitStatusActivePower
Integer32,
pduUnitStatusApparentPower
Integer32,
pduUnitStatusPeakPower
Integer32,
pduUnitStatusPeakPowerTimestamp
DisplayString,
pduUnitStatusPeakPowerStartTime
DisplayString,
pduUnitStatusEnergy
Integer32,
pduUnitStatusResettableEnergy
Integer32,
pduUnitStatusEnergyStartTime
DisplayString,
pduUnitStatusOutletsEnergyStartTime
DisplayString
}
pduUnitStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU status table entry"
::= { pduUnitStatusEntry 1 }
pduUnitStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { pduUnitStatusEntry 2 }
pduUnitStatusLoadState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the present load status of the PDU based on Active Power."
::= { pduUnitStatusEntry 3 }
pduUnitStatusActivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Watts(W),
of the PDU being queried."
::= { pduUnitStatusEntry 4 }
pduUnitStatusApparentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Volt-Amps(VA)
of the PDU load being queried."
::= { pduUnitStatusEntry 5 }
pduUnitStatusPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns peak power consumption, in Watts(W),
of the PDU being queried."
::= { pduUnitStatusEntry 6 }
pduUnitStatusPeakPowerTimestamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time that peak power consumption occurred"
::= { pduUnitStatusEntry 7 }
pduUnitStatusPeakPowerStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time of the last device peak power reset"
::= { pduUnitStatusEntry 8 }
pduUnitStatusEnergy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime."
::= { pduUnitStatusEntry 9 }
pduUnitStatusResettableEnergy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user resettable energy meter measuring PDU energy consumption
in tenths of kilowatt-hours(kWh)."
::= { pduUnitStatusEntry 10 }
pduUnitStatusEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time of the last device energy meter reset"
::= { pduUnitStatusEntry 11 }
pduUnitStatusOutletsEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time of the last outlets energy meter reset"
::= { pduUnitStatusEntry 12 }
-- Start pduInputPhase
pduInputPhaseTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PDU Input Phases "
::= { pduInputPhase 1 }
pduInputPhaseConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduInputPhaseConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Input Phase configuration data"
::= { pduInputPhase 2 }
pduInputPhaseConfigEntry OBJECT-TYPE
SYNTAX PduInputPhaseConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An input phase entry containing objects for a particular input phase."
INDEX { pduUnitConfigIndex, pduInputPhaseConfigIndex }
::= { pduInputPhaseConfigTable 1 }
PduInputPhaseConfigEntry ::= SEQUENCE {
pduInputPhaseConfigIndex
Integer32,
pduInputPhaseConfigCount
Integer32,
pduInputPhaseConfigOverloadRestriction
INTEGER,
pduInputPhaseConfigCurrentLowerCriticalThreshold
Unsigned32,
pduInputPhaseConfigCurrentLowerWarningThreshold
Unsigned32,
pduInputPhaseConfigCurrentUpperCriticalThreshold
Unsigned32,
pduInputPhaseConfigCurrentUpperWarningThreshold
Unsigned32,
pduInputPhaseConfigVoltageLowerCriticalThreshold
Unsigned32,
pduInputPhaseConfigVoltageLowerWarningThreshold
Unsigned32,
pduInputPhaseConfigVoltageUpperCriticalThreshold
Unsigned32,
pduInputPhaseConfigVoltageUpperWarningThreshold
Unsigned32,
pduInputPhaseConfigCurrentAlarmResetThreshold
Unsigned32,
pduInputPhaseConfigCurrentAlarmStateChangeDelay
Integer32,
pduInputPhaseConfigCurrentEnabledThresholds
BITS,
pduInputPhaseConfigVoltageAlarmResetThreshold
Unsigned32,
pduInputPhaseConfigVoltageAlarmStateChangeDelay
Integer32,
pduInputPhaseConfigVoltageEnabledThresholds
BITS
}
pduInputPhaseConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Input Phase configuration table entry"
::= { pduInputPhaseConfigEntry 1 }
pduInputPhaseConfigCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Input Phases"
::= { pduInputPhaseConfigEntry 2 }
pduInputPhaseConfigOverloadRestriction OBJECT-TYPE
SYNTAX INTEGER {
alwaysAllowTurnOn (1),
restrictOnUpperWarning (2),
restrictOnUpperCritical (3),
notSupported (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This OID controls the behavior of a Switched PDU Input Phase when an
overload condition is possible and additional outlets are requested
to be turned on. Setting this OID to alwaysAllowTurnON (1) will always
allow the outlets on the corresponding Input Phase to turn on. Setting
this OID to restrictOnUpperWarning (2) will not allow outlets on the
corresponding Input Phase to turn on if the
pduInputPhaseConfigUpperWarningThreshold OID is exceeded. Setting
this OID to restrictOnUpperCritical (3) will not allow outlets on
the corresponding Input Phase to turn on if the
pduInputPhaseConfigUpperCriticalThreshold OID is exceeded. Models
that do not support this feature will respond to this OID with a
value of notSupported (4). Attempts to set this OID in these
models will fail. "
::= { pduInputPhaseConfigEntry 3 }
pduInputPhaseConfigCurrentLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical input phase current alarm threshold in hundredths of Amps(A)."
::= { pduInputPhaseConfigEntry 4 }
pduInputPhaseConfigCurrentLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)."
::= { pduInputPhaseConfigEntry 5 }
pduInputPhaseConfigCurrentUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical input phase current alarm threshold in hundredths of Amps(A)."
::= { pduInputPhaseConfigEntry 6 }
pduInputPhaseConfigCurrentUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)."
::= { pduInputPhaseConfigEntry 7 }
pduInputPhaseConfigVoltageLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical input phase voltage alarm threshold in Volts(V)."
::= { pduInputPhaseConfigEntry 8 }
pduInputPhaseConfigVoltageLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V)."
::= { pduInputPhaseConfigEntry 9 }
pduInputPhaseConfigVoltageUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical input phase voltage alarm threshold in Volts(V)."
::= { pduInputPhaseConfigEntry 10 }
pduInputPhaseConfigVoltageUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V)."
::= { pduInputPhaseConfigEntry 11 }
pduInputPhaseConfigCurrentAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for current alarm deassertions in hundredths of Amps(A)."
::= { pduInputPhaseConfigEntry 12 }
pduInputPhaseConfigCurrentAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a current state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the assertion condition
must exist for n+1 consecutive samples before the corresponding
assertion event is reported. "
::= { pduInputPhaseConfigEntry 13 }
pduInputPhaseConfigCurrentEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which current alarm thresholds are enabled."
::= { pduInputPhaseConfigEntry 14 }
pduInputPhaseConfigVoltageAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for voltage alarm deassertions in Volts(V)."
::= { pduInputPhaseConfigEntry 15 }
pduInputPhaseConfigVoltageAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a voltage state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the assertion condition
must exist for n+1 consecutive samples before the corresponding
assertion event is reported. "
::= { pduInputPhaseConfigEntry 16 }
pduInputPhaseConfigVoltageEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which voltage alarm thresholds are enabled."
::= { pduInputPhaseConfigEntry 17 }
pduInputPhasePropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduInputPhasePropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Input Phase properties"
::= { pduInputPhase 3 }
pduInputPhasePropertiesEntry OBJECT-TYPE
SYNTAX PduInputPhasePropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An input phase properties entry containing objects for a particular input phase."
INDEX { pduUnitPropertiesIndex, pduInputPhasePropertiesIndex }
::= { pduInputPhasePropertiesTable 1 }
PduInputPhasePropertiesEntry ::= SEQUENCE {
pduInputPhasePropertiesIndex
Integer32,
pduInputPhasePropertiesCount
Integer32
}
pduInputPhasePropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Input Phase status entry"
::= { pduInputPhasePropertiesEntry 1 }
pduInputPhasePropertiesCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Input Phase ID"
::= { pduInputPhasePropertiesEntry 2 }
pduInputPhaseStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduInputPhaseStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Input Phase status data"
::= { pduInputPhase 4 }
pduInputPhaseStatusEntry OBJECT-TYPE
SYNTAX PduInputPhaseStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An input phase status entry containing objects for a particular input phase."
INDEX { pduUnitStatusIndex, pduInputPhaseStatusIndex }
::= { pduInputPhaseStatusTable 1 }
PduInputPhaseStatusEntry ::= SEQUENCE {
pduInputPhaseStatusIndex
Integer32,
pduInputPhaseStatusCount
Integer32,
pduInputPhaseStatusCurrentState
INTEGER,
pduInputPhaseStatusVoltageState
INTEGER,
pduInputPhaseStatusCurrent
Integer32,
pduInputPhaseStatusVoltage
Integer32,
pduInputPhaseStatusActivePower
Integer32,
pduInputPhaseStatusApparentPower
Integer32,
pduInputPhaseStatusPowerFactor
Integer32
}
pduInputPhaseStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Input Phase status entry"
::= { pduInputPhaseStatusEntry 1 }
pduInputPhaseStatusCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Input Phase ID"
::= { pduInputPhaseStatusEntry 2 }
pduInputPhaseStatusCurrentState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present current status of the PDU Phase in case of Y connection or PDU Line in case of Delta conneciton."
::= { pduInputPhaseStatusEntry 3 }
pduInputPhaseStatusVoltageState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present voltage status of the PDU Input Phase being queried"
::= { pduInputPhaseStatusEntry 4 }
pduInputPhaseStatusCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current draw, in hundredths of Amps(A), of the load on the
PDU Phase/Line being queried. Nodes with
pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
"
::= { pduInputPhaseStatusEntry 5 }
pduInputPhaseStatusVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the voltage, in Volts(V), of the PDU Phase/Line being queried.
Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
"
::= { pduInputPhaseStatusEntry 6 }
pduInputPhaseStatusActivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Watts(W), consumed on the PDU Phase/Line
being queried. Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection
Phase values or Delta connection Line values, and nodes with
pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
"
::= { pduInputPhaseStatusEntry 7 }
pduInputPhaseStatusApparentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Volt-Amps(VA), of the PDU Phase/Line being queried.
Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
"
::= { pduInputPhaseStatusEntry 8 }
pduInputPhaseStatusPowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the ratio of active to apparent power of the PDU Phase/Line being queried.
Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
"
::= { pduInputPhaseStatusEntry 9 }
-- Start pduCircuitBreaker
pduCircuitBreakerTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PDU Circuit Breakers"
::= { pduCircuitBreaker 1 }
pduCircuitBreakerConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduCircuitBreakerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Circuit Breaker configuration data"
::= { pduCircuitBreaker 2 }
pduCircuitBreakerConfigEntry OBJECT-TYPE
SYNTAX PduCircuitBreakerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker configuration entry containing objects for a particular circuit breaker."
INDEX { pduUnitConfigIndex, pduCircuitBreakerConfigIndex }
::= { pduCircuitBreakerConfigTable 1 }
PduCircuitBreakerConfigEntry ::= SEQUENCE {
pduCircuitBreakerConfigIndex
Integer32,
pduCircuitBreakerConfigCount
Integer32,
pduCircuitBreakerName
DisplayString,
pduCircuitBreakerConfigOverloadRestriction
INTEGER,
pduCircuitBreakerConfigLowerCriticalThreshold
Unsigned32,
pduCircuitBreakerConfigLowerWarningThreshold
Unsigned32,
pduCircuitBreakerConfigUpperCriticalThreshold
Unsigned32,
pduCircuitBreakerConfigUpperWarningThreshold
Unsigned32,
pduCircuitBreakerConfigAlarmResetThreshold
Unsigned32,
pduCircuitBreakerConfigAlarmStateChangeDelay
Unsigned32,
pduCircuitBreakerConfigEnabledThresholds
BITS
}
pduCircuitBreakerConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker configuration table entry"
::= { pduCircuitBreakerConfigEntry 1 }
pduCircuitBreakerConfigCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of circuit breakers on the PDU"
::= { pduCircuitBreakerConfigEntry 2 }
pduCircuitBreakerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label of the circuit breaker"
::= { pduCircuitBreakerConfigEntry 3 }
pduCircuitBreakerConfigOverloadRestriction OBJECT-TYPE
SYNTAX INTEGER {
alwaysAllowTurnOn (1),
restrictOnUpperWarning (2),
restrictOnUpperCritical (3),
notSupported (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This OID controls the behavior of a Switched PDU Circuit
Breaker when an overload condition is possible and additional
outlets are requested to be turned on. Setting this OID to
alwaysAllowTurnON (1) will always allow the outlets on the
corresponding Circuit Breaker to turn on. Setting this OID
to restrictOnUpperWarning (2) will not allow outlets on the
corresponding Circuit Breaker to turn on if the
pduCircuitBreakerConfigUpperWarningThreshold OID is exceeded.
Setting this OID to restrictOnUpperCritical (3) will not
allow outlets on the corresponding Circuit Breaker to turn
on if the pduCircuitBreakerConfigUpperCriticalThreshold OID
is exceeded. Models that do not support this feature will
respond to this OID with a value of notSupported (4).
Attempts to set this OID in these models will fail. "
::= { pduCircuitBreakerConfigEntry 4 }
pduCircuitBreakerConfigLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical circuit breaker current alarm threshold in hundredths of Amps(A)."
::= { pduCircuitBreakerConfigEntry 5 }
pduCircuitBreakerConfigLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)."
::= { pduCircuitBreakerConfigEntry 6 }
pduCircuitBreakerConfigUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical circuit breaker current alarm threshold in hundredths of Amps(A)."
::= { pduCircuitBreakerConfigEntry 7 }
pduCircuitBreakerConfigUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)."
::= { pduCircuitBreakerConfigEntry 8 }
pduCircuitBreakerConfigAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for deassertions in hundredths of Amps(A)."
::= { pduCircuitBreakerConfigEntry 9 }
pduCircuitBreakerConfigAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon
as it is detected; if it is non-zero, say n, then the
assertion condition must exist for n+1 consecutive samples
before the corresponding assertion event is reported."
::= { pduCircuitBreakerConfigEntry 10 }
pduCircuitBreakerConfigEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which alarm thresholds are enabled."
::= { pduCircuitBreakerConfigEntry 11 }
pduCircuitBreakerPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduCircuitBreakerPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU circuit breaker properties"
::= { pduCircuitBreaker 3 }
pduCircuitBreakerPropertiesEntry OBJECT-TYPE
SYNTAX PduCircuitBreakerPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker properties entry containing objects for a particular circuit breaker."
INDEX { pduUnitPropertiesIndex, pduCircuitBreakerPropertiesIndex }
::= { pduCircuitBreakerPropertiesTable 1 }
PduCircuitBreakerPropertiesEntry ::= SEQUENCE {
pduCircuitBreakerPropertiesIndex
Integer32,
pduCircuitBreakerPropertiesCount
Integer32,
pduCircuitBreakerPropertiesInputLayout
INTEGER
}
pduCircuitBreakerPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker properties table entry"
::= { pduCircuitBreakerPropertiesEntry 1 }
pduCircuitBreakerPropertiesCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Circuit Breakers"
::= { pduCircuitBreakerPropertiesEntry 2 }
pduCircuitBreakerPropertiesInputLayout OBJECT-TYPE
SYNTAX INTEGER {
seqPhase1ToNeutral (1),
seqPhase2ToNeutral (2),
seqPhase3ToNeutral (3),
seqPhase1ToPhase2 (4),
seqPhase2ToPhase3 (5),
seqPhase3ToPhase1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID describes the outlet phase connections on
the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets attached
to circuit breaker are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that outlets attached
to circuit breaker are connected from Phase 2 to Neutral.
seqPhase3ToNeutral(3) indicates that outlets attached
to circuit breaker are connected from Phase 3 to Neutral.
seqPhase1ToPhase2(4) indicates that outlets attached
to circuit breaker are connected from Phase 1 to Phase2.
seqPhase2ToPhase3(5) indicates that outlets attached
to circuit breaker are connected from Phase 2 to Phase3.
seqPhase3ToPhase1(6) indicates that outlets attached
to circuit breaker are connected from Phase 3 to Phase1. "
::= { pduCircuitBreakerPropertiesEntry 3 }
pduCircuitBreakerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduCircuitBreakerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU circuit breaker status data"
::= { pduCircuitBreaker 4 }
pduCircuitBreakerStatusEntry OBJECT-TYPE
SYNTAX PduCircuitBreakerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker status entry containing objects for a particular circuit breaker."
INDEX { pduUnitStatusIndex, pduCircuitBreakerStatusIndex }
::= { pduCircuitBreakerStatusTable 1 }
PduCircuitBreakerStatusEntry ::= SEQUENCE {
pduCircuitBreakerStatusIndex
Integer32,
pduCircuitBreakerStatusCount
Integer32,
pduCircuitBreakerLabel
DisplayString,
pduCircuitBreakerStatusLoadState
INTEGER,
pduCircuitBreakerStatusCurrent
Integer32
}
pduCircuitBreakerStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker status table entry"
::= { pduCircuitBreakerStatusEntry 1 }
pduCircuitBreakerStatusCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Circuit Breakers"
::= { pduCircuitBreakerStatusEntry 2 }
pduCircuitBreakerLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label on the PDU identifying the circuit breaker"
::= { pduCircuitBreakerStatusEntry 3 }
pduCircuitBreakerStatusLoadState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5),
off (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present load status of the PDU Circuit
Breaker being queried"
::= { pduCircuitBreakerStatusEntry 4 }
pduCircuitBreakerStatusCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current draw, in hundredths of Amps(A), of the load on
the PDU Circuit Breaker being queried."
::= { pduCircuitBreakerStatusEntry 5 }
-- Start pduOutlet
pduOutletSwitchedTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PDU Outlets"
::= { pduOutlet 1 }
pduOutletSwitchedConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletSwitchedConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Switched Outlet configuration data"
::= { pduOutlet 2 }
pduOutletSwitchedConfigEntry OBJECT-TYPE
SYNTAX PduOutletSwitchedConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An outlet configuration entry containing objects for a particular outlet."
INDEX { pduUnitConfigIndex, pduOutletSwitchedConfigIndex }
::= { pduOutletSwitchedConfigTable 1 }
PduOutletSwitchedConfigEntry ::= SEQUENCE {
pduOutletSwitchedConfigIndex
Integer32,
pduOutletSwitchedName
DisplayString,
pduOutletSwitchedStateOnStartup
INTEGER,
pduOutletSwitchedConfigPowerOnTime
Integer32,
pduOutletSwitchedConfigPowerOffTime
Integer32,
pduOutletSwitchedConfigRebootDuration
Integer32
}
pduOutletSwitchedConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Switched Outlet configuration table entry"
::= { pduOutletSwitchedConfigEntry 1 }
pduOutletSwitchedName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user-defined name for the Switched Outlet"
::= { pduOutletSwitchedConfigEntry 2 }
pduOutletSwitchedStateOnStartup OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
lastKnownState (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The outlet state on device startup; overrides
the global value pduUnitConfigGlobalOutletStateOnStartup."
::= { pduOutletSwitchedConfigEntry 3 }
pduOutletSwitchedConfigPowerOnTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of delay, in seconds, between when power is
provided to outlets the outlet and when this outlet
starts providing power"
::= { pduOutletSwitchedConfigEntry 4 }
pduOutletSwitchedConfigPowerOffTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time, in seconds, this outlet will delay
powering off"
::= { pduOutletSwitchedConfigEntry 5 }
pduOutletSwitchedConfigRebootDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time, in seconds, this outlet will remain
in powered off state before returning to power on state
during a reboot action."
::= { pduOutletSwitchedConfigEntry 6 }
pduOutletSwitchedPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletSwitchedPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Switched Outlet properties"
::= { pduOutlet 3 }
pduOutletSwitchedPropertiesEntry OBJECT-TYPE
SYNTAX PduOutletSwitchedPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An outlet properties entry containing objects for a particular outlet."
INDEX { pduUnitPropertiesIndex, pduOutletSwitchedPropertiesIndex }
::= { pduOutletSwitchedPropertiesTable 1 }
PduOutletSwitchedPropertiesEntry ::= SEQUENCE {
pduOutletSwitchedPropertiesIndex
Integer32,
pduOutletSwitchedPropertiesNumber
Integer32,
pduOutletSwitchedPropertiesName
DisplayString,
pduOutletSwitchedPropertiesInputPhaseLayout
INTEGER,
pduOutletSwitchedPropertiesCircuitBreaker
Integer32
}
pduOutletSwitchedPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Switched Outlet properties table entry"
::= { pduOutletSwitchedPropertiesEntry 1 }
pduOutletSwitchedPropertiesNumber OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Switched Outlet ID"
::= { pduOutletSwitchedPropertiesEntry 2 }
pduOutletSwitchedPropertiesName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined switched outlet ID string"
::= { pduOutletSwitchedPropertiesEntry 3 }
pduOutletSwitchedPropertiesInputPhaseLayout OBJECT-TYPE
SYNTAX INTEGER {
seqPhase1ToNeutral (1),
seqPhase2ToNeutral (2),
seqPhase3ToNeutral (3),
seqPhase1ToPhase2 (4),
seqPhase2ToPhase3 (5),
seqPhase3ToPhase1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID describes the outlet phase connections
on the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets
attached to Switched Outlet are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that outlets
attached to Switched Outlet are connected from Phase 2 to Neutral.
seqPhase3ToNeutral(3) indicates that outlets
attached to Switched Outlet are connected from Phase 3 to Neutral.
seqPhase1ToPhase2(4) indicates that outlets
attached to Switched Outlet are connected from Phase 1 to Phase2.
seqPhase2ToPhase3(5) indicates that outlets
attached to Switched Outlet are connected from Phase 2 to Phase3.
seqPhase3ToPhase1(6) indicates that outlets
attached to Switched Outlet are connected from Phase 3 to Phase1. "
::= { pduOutletSwitchedPropertiesEntry 4 }
pduOutletSwitchedPropertiesCircuitBreaker OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Circuit Breaker ID"
::= { pduOutletSwitchedPropertiesEntry 5 }
pduOutletSwitchedStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletSwitchedStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Switched Outlet status data"
::= { pduOutlet 4 }
pduOutletSwitchedStatusEntry OBJECT-TYPE
SYNTAX PduOutletSwitchedStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status data from the PDU Switched Outlet being queried"
INDEX { pduUnitStatusIndex, pduOutletSwitchedStatusIndex }
::= { pduOutletSwitchedStatusTable 1 }
PduOutletSwitchedStatusEntry ::= SEQUENCE {
pduOutletSwitchedStatusIndex
Integer32,
pduOutletSwitchedStatusNumber
Integer32,
pduOutletSwitchedStatusName
DisplayString,
pduOutletSwitchedStatusState
INTEGER
}
pduOutletSwitchedStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Switched Outlet status table entry"
::= { pduOutletSwitchedStatusEntry 1 }
pduOutletSwitchedStatusNumber OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Switched Outlet ID"
::= { pduOutletSwitchedStatusEntry 2 }
pduOutletSwitchedStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined switched outlet ID string"
::= { pduOutletSwitchedStatusEntry 3 }
pduOutletSwitchedStatusState OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present switch state of the
PDU switched outlet being queried"
::= { pduOutletSwitchedStatusEntry 4 }
pduOutletSwitchedControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletSwitchedControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Switched Outlet status data"
::= { pduOutlet 5 }
pduOutletSwitchedControlEntry OBJECT-TYPE
SYNTAX PduOutletSwitchedControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status data from the PDU Switched Outlet
being queried"
INDEX { pduUnitConfigIndex, pduOutletSwitchedControlIndex }
::= { pduOutletSwitchedControlTable 1 }
PduOutletSwitchedControlEntry ::= SEQUENCE {
pduOutletSwitchedControlIndex
Integer32,
pduOutletSwitchedControlNumber
Integer32,
pduOutletSwitchedControlName
DisplayString,
pduOutletSwitchedControlCommand
INTEGER
}
pduOutletSwitchedControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index to the PDU switched outlet
control data table entry"
::= { pduOutletSwitchedControlEntry 1 }
pduOutletSwitchedControlNumber OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Switched Outlet ID"
::= { pduOutletSwitchedControlEntry 2 }
pduOutletSwitchedControlName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined switched outlet ID string"
::= { pduOutletSwitchedControlEntry 3 }
pduOutletSwitchedControlCommand OBJECT-TYPE
SYNTAX INTEGER {
immediateOff (1),
immediateOn (2),
delayedOff (3),
delayedOn (4),
immediateReboot (5),
delayedReboot (6),
outletUnknown (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Getting this variable will return the outlet state.
If the outlet is on, the immediateOn (2)
value will be returned. If the outlet is off,
the immediateOff (1) value will be returned.
If the state of the outlet cannot be determined, the
outletUnknown (7) value will be returned. If the
outletUnknown condition should occur, all devices
powered by the PDU should be shut down. The PDU's
power should then be cycled to clear this condition.
Setting this variable to immediateOn (2) will immediately
turn the outlet on. Setting this variable to
immediateOff (1) will immediately turn the outlet off.
Setting this variable to immediateReboot (5)
will cause the Switched PDU to perform an immediateOff
command, wait the pduOutletSwitchedConfigRebootDuration
OID time, and then perform an immediateOn command.
Setting this variable to delayedOn (4) will turn the
outlet on after the pduOutletSwitchedConfigPowerOnTime
OID time has elapsed. Setting this variable to
delayedOff (3) will turn the outlet off after the
pduOutletSwitchedConfigPowerOffTime OID time has elapsed.
Setting this variable to delayedReboot (6) will cause
the Switched PDU to perform a delayedOff command, wait
the pduOutletSwitchedConfigRebootDuration OID time, and
then perform a delayedOn command."
::= { pduOutletSwitchedControlEntry 4 }
pduOutletMeteredTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PDU Outlets"
::= { pduOutlet 6 }
pduOutletMeteredConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletMeteredConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Metered Outlet configuration data"
::= { pduOutlet 7 }
pduOutletMeteredConfigEntry OBJECT-TYPE
SYNTAX PduOutletMeteredConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An outlet configuration entry containing objects for a particular outlet."
INDEX { pduUnitConfigIndex, pduOutletMeteredConfigIndex }
::= { pduOutletMeteredConfigTable 1 }
PduOutletMeteredConfigEntry ::= SEQUENCE {
pduOutletMeteredConfigIndex
Integer32,
pduOutletMeteredName
DisplayString,
pduOutletMeteredConfigLowerCriticalThreshold
Unsigned32,
pduOutletMeteredConfigLowerWarningThreshold
Unsigned32,
pduOutletMeteredConfigUpperCriticalThreshold
Unsigned32,
pduOutletMeteredConfigUpperWarningThreshold
Unsigned32,
pduOutletMeteredConfigAlarmResetThreshold
Unsigned32,
pduOutletMeteredConfigAlarmStateChangeDelay
Unsigned32,
pduOutletMeteredConfigEnabledThresholds
BITS
}
pduOutletMeteredConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Metered Outlet
configuration table entry"
::= { pduOutletMeteredConfigEntry 1 }
pduOutletMeteredName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user-defined name for the Metered Outlet"
::= { pduOutletMeteredConfigEntry 2 }
pduOutletMeteredConfigLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical outlet active power alarm threshold in Watts(W)."
::= { pduOutletMeteredConfigEntry 3 }
pduOutletMeteredConfigLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) outlet active power alarm threshold in Watts(W)."
::= { pduOutletMeteredConfigEntry 4 }
pduOutletMeteredConfigUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical outlet active power alarm threshold in Watts(W)."
::= { pduOutletMeteredConfigEntry 5 }
pduOutletMeteredConfigUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) outlet active power alarm threshold in Watts(W)."
::= { pduOutletMeteredConfigEntry 6 }
pduOutletMeteredConfigAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for deassertions in Watts(W)."
::= { pduOutletMeteredConfigEntry 7 }
pduOutletMeteredConfigAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a state
is asserted. If the value is zero, then the state
is asserted as soon as it is detected; if it is
non-zero, say n, then the assertion condition must
exist for n+1 consecutive samples before the
corresponding assertion event is reported."
::= { pduOutletMeteredConfigEntry 8 }
pduOutletMeteredConfigEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which alarm
thresholds are enabled."
::= { pduOutletMeteredConfigEntry 9 }
pduOutletMeteredPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletMeteredPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Metered Outlet properties"
::= { pduOutlet 8 }
pduOutletMeteredPropertiesEntry OBJECT-TYPE
SYNTAX PduOutletMeteredPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration data from the PDU Metered
Outlet being queried"
INDEX { pduUnitPropertiesIndex, pduOutletMeteredPropertiesIndex }
::= { pduOutletMeteredPropertiesTable 1 }
PduOutletMeteredPropertiesEntry ::= SEQUENCE {
pduOutletMeteredPropertiesIndex
Integer32,
pduOutletMeteredPropertiesNumber
Integer32,
pduOutletMeteredPropertiesName
DisplayString,
pduOutletMeteredPropertiesInputPhaseLayout
INTEGER,
pduOutletMeteredPropertiesCircuitBreaker
Integer32,
pduOutletMeteredPropertiesPowerRating
Integer32
}
pduOutletMeteredPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Metered Outlet
properties table entry"
::= { pduOutletMeteredPropertiesEntry 1 }
pduOutletMeteredPropertiesNumber OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Metered Outlet ID"
::= { pduOutletMeteredPropertiesEntry 2 }
pduOutletMeteredPropertiesName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined Metered outlet ID string"
::= { pduOutletMeteredPropertiesEntry 3 }
pduOutletMeteredPropertiesInputPhaseLayout OBJECT-TYPE
SYNTAX INTEGER {
seqPhase1ToNeutral (1),
seqPhase2ToNeutral (2),
seqPhase3ToNeutral (3),
seqPhase1ToPhase2 (4),
seqPhase2ToPhase3 (5),
seqPhase3ToPhase1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID describes the outlet phase connections
on the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets attached
to Metered Outlet are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that outlets attached
to Metered Outlet are connected from Phase 2 to Neutral.
seqPhase3ToNeutral(3) indicates that outlets attached
to Metered Outlet are connected from Phase 3 to Neutral.
seqPhase1ToPhase2(4) indicates that outlets attached
to Metered Outlet are connected from Phase 1 to Phase2.
seqPhase2ToPhase3(5) indicates that outlets attached
to Metered Outlet are connected from Phase 2 to Phase3.
seqPhase3ToPhase1(6) indicates that outlets attached
to Metered Outlet are connected from Phase 3 to Phase1. "
::= { pduOutletMeteredPropertiesEntry 4 }
pduOutletMeteredPropertiesCircuitBreaker OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Circuit Breaker ID"
::= { pduOutletMeteredPropertiesEntry 5 }
pduOutletMeteredPropertiesPowerRating OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum power rating of the PDU metered outlet"
::= { pduOutletMeteredPropertiesEntry 6 }
pduOutletMeteredStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduOutletMeteredStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Metered Outlet status data"
::= { pduOutlet 9 }
pduOutletMeteredStatusEntry OBJECT-TYPE
SYNTAX PduOutletMeteredStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status data from the PDU Metered Outlet being queried"
INDEX { pduUnitStatusIndex, pduOutletMeteredStatusIndex }
::= { pduOutletMeteredStatusTable 1 }
PduOutletMeteredStatusEntry ::= SEQUENCE {
pduOutletMeteredStatusIndex
Integer32,
pduOutletMeteredStatusNumber
Integer32,
pduOutletMeteredStatusName
DisplayString,
pduOutletMeteredStatusLoadState
INTEGER,
pduOutletMeteredStatusCurrent
Integer32,
pduOutletMeteredStatusActivePower
Integer32,
pduOutletMeteredStatusPowerFactor
Integer32,
pduOutletMeteredStatusPeakPower
Integer32,
pduOutletMeteredStatusPeakPowerTimeStamp
DisplayString,
pduOutletMeteredStatusPeakPowerStartTime
DisplayString,
pduOutletMeteredStatusResettableEnergy
Integer32
}
pduOutletMeteredStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Metered Outlet status table entry"
::= { pduOutletMeteredStatusEntry 1 }
pduOutletMeteredStatusNumber OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Metered Outlet ID"
::= { pduOutletMeteredStatusEntry 2 }
pduOutletMeteredStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined Metered outlet ID string"
::= { pduOutletMeteredStatusEntry 3 }
pduOutletMeteredStatusLoadState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the present load status of the PDU metered outlet being queried."
::= { pduOutletMeteredStatusEntry 4 }
pduOutletMeteredStatusCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current draw, in hundredths of Amps(A), of the load on the PDU
outlet being queried."
::= { pduOutletMeteredStatusEntry 5 }
pduOutletMeteredStatusActivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the power draw, in Watts(W), of the load
on the PDU outlet being queried."
::= { pduOutletMeteredStatusEntry 6 }
pduOutletMeteredStatusPowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the ratio of active to apparent power
of the PDU Outlet being queried"
::= { pduOutletMeteredStatusEntry 7 }
pduOutletMeteredStatusPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns peak power consumption, in Watts(W),
of the Rack PDU outlet being queried."
::= { pduOutletMeteredStatusEntry 8 }
pduOutletMeteredStatusPeakPowerTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time that this metered
outlet's peak power consumption occurred"
::= { pduOutletMeteredStatusEntry 9 }
pduOutletMeteredStatusPeakPowerStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the start date and time that this metered
outlet began recording peak power observations"
::= { pduOutletMeteredStatusEntry 10 }
pduOutletMeteredStatusResettableEnergy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user resettable energy meter measuring outlet load energy
consumption in tenths of Kilowatt-Hours(kWh)."
::= { pduOutletMeteredStatusEntry 11 }
-- Start pduExternalSensor
pduExternalSensorTableSize OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of External Sensors"
::= { pduExternalSensor 1 }
pduExternalSensorNamePlateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduExternalSensorNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU ExternalSensorNamePlate data"
::= { pduExternalSensor 2 }
pduExternalSensorNamePlateEntry OBJECT-TYPE
SYNTAX PduExternalSensorNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"External Sensor Name Plate data from the external
sensor being queried. The number of entries equals
the value of pduExternalSensorNamePlateTableSize."
INDEX { pduNamePlateIndex, pduExternalSensorNamePlateIndex }
::= { pduExternalSensorNamePlateTable 1 }
PduExternalSensorNamePlateEntry ::= SEQUENCE {
pduExternalSensorNamePlateIndex
Integer32,
pduExternalSensorNamePlateName
DisplayString,
pduExternalSensorNamePlateDescription
DisplayString,
pduExternalSensorNamePlateLocation
DisplayString,
pduExternalSensorNamePlateSerialNumber
DisplayString,
pduExternalSensorNamePlateType
INTEGER,
pduExternalSensorNamePlateUnits
INTEGER,
pduExternalSensorNamePlateIdentifier
Integer32
}
pduExternalSensorNamePlateIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor status table entry"
::= { pduExternalSensorNamePlateEntry 1 }
pduExternalSensorNamePlateName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the external sensor"
::= { pduExternalSensorNamePlateEntry 2 }
pduExternalSensorNamePlateDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined description of the external sensor"
::= { pduExternalSensorNamePlateEntry 3 }
pduExternalSensorNamePlateLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the location of the PDU"
::= { pduExternalSensorNamePlateEntry 4 }
pduExternalSensorNamePlateSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the external sensor being queried"
::= { pduExternalSensorNamePlateEntry 5 }
pduExternalSensorNamePlateType OBJECT-TYPE
SYNTAX INTEGER {
temperature (1),
humidity (2),
doorSwitch (3),
dryContact (4),
spotFluid (5),
ropeFluid (6),
smoke (7),
beacon (8),
airVelocity (9),
modbusAdapter (17),
hidAdapter (18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of external sensor."
::= { pduExternalSensorNamePlateEntry 6 }
pduExternalSensorNamePlateUnits OBJECT-TYPE
SYNTAX INTEGER {
logic (0),
degreeC (1),
degreeF (2),
percent (3),
mps (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The base units the external sensor is measured in.
This parameter does not apply to onOff, trip, vibration,
waterDetection, smokeDetection sensors. "
::= { pduExternalSensorNamePlateEntry 7 }
pduExternalSensorNamePlateIdentifier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the external sensor."
::= { pduExternalSensorNamePlateEntry 8 }
pduExternalSensorConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduExternalSensorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU External Sensor configuration data"
::= { pduExternalSensor 3 }
pduExternalSensorConfigEntry OBJECT-TYPE
SYNTAX PduExternalSensorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration data from the PDU External
Sensor being queried"
INDEX { pduUnitConfigIndex, pduExternalSensorConfigIndex }
::= { pduExternalSensorConfigTable 1 }
PduExternalSensorConfigEntry ::= SEQUENCE {
pduExternalSensorConfigIndex
Integer32,
pduExternalSensorConfigLowerCriticalThreshold
Unsigned32,
pduExternalSensorConfigLowerWarningThreshold
Unsigned32,
pduExternalSensorConfigUpperCriticalThreshold
Unsigned32,
pduExternalSensorConfigUpperWarningThreshold
Unsigned32,
pduExternalSensorConfigAlarmResetThreshold
Unsigned32,
pduExternalSensorConfigAlarmStateChangeDelay
Unsigned32,
pduExternalSensorConfigEnabledThresholds
BITS,
pduExternalSensorConfigAlarmState
INTEGER
}
pduExternalSensorConfigIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor
configuration table entry"
::= { pduExternalSensorConfigEntry 1 }
pduExternalSensorConfigLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical alarm threshold in pduExternalSensorNamePlateUnits."
::= { pduExternalSensorConfigEntry 2 }
pduExternalSensorConfigLowerWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits."
::= { pduExternalSensorConfigEntry 3 }
pduExternalSensorConfigUpperCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper critical alarm threshold in pduExternalSensorNamePlateUnits."
::= { pduExternalSensorConfigEntry 4 }
pduExternalSensorConfigUpperWarningThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined upper non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits."
::= { pduExternalSensorConfigEntry 5 }
pduExternalSensorConfigAlarmResetThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hysteresis used for deassertions."
::= { pduExternalSensorConfigEntry 6 }
pduExternalSensorConfigAlarmStateChangeDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay measured in samples before a state is
asserted. If the value is zero, then the state is
asserted as soon as it is detected; if it is non-zero,
say n, then the assertion condition must exist for n+1
consecutive samples before the corresponding assertion
event is reported."
::= { pduExternalSensorConfigEntry 7 }
pduExternalSensorConfigEnabledThresholds OBJECT-TYPE
SYNTAX BITS {
lowerCritical (0),
lowerWarning (1),
upperWarning (2),
upperCritical (3),
binarySensorAlarm (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bit string indicating which alarm
thresholds are enabled."
::= { pduExternalSensorConfigEntry 8 }
pduExternalSensorConfigAlarmState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined alarm state of external sensor"
::= { pduExternalSensorConfigEntry 9 }
pduExternalSensorStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduExternalSensorStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU External Sensor status data"
::= { pduExternalSensor 4 }
pduExternalSensorStatusEntry OBJECT-TYPE
SYNTAX PduExternalSensorStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status data from the PDU External Sensor
being queried"
INDEX { pduUnitStatusIndex, pduExternalSensorStatusIndex }
::= { pduExternalSensorStatusTable 1 }
PduExternalSensorStatusEntry ::= SEQUENCE {
pduExternalSensorStatusIndex
Integer32,
pduExternalSensorStatusName
DisplayString,
pduExternalSensorStatusAisle
INTEGER,
pduExternalSensorStatusCommStatus
INTEGER,
pduExternalSensorStatusState
INTEGER,
pduExternalSensorStatusValue
Integer32,
pduExternalSensorStatusTimeStamp
DisplayString,
pduExternalSensorStatusHighPrecisionValue
Integer32
}
pduExternalSensorStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor status table entry"
::= { pduExternalSensorStatusEntry 1 }
pduExternalSensorStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined name for the External Sensor"
::= { pduExternalSensorStatusEntry 2 }
pduExternalSensorStatusAisle OBJECT-TYPE
SYNTAX INTEGER {
hotAisle (1),
coldAisle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the external sensor is
in a hot or cold aisle"
::= { pduExternalSensorStatusEntry 3 }
pduExternalSensorStatusCommStatus OBJECT-TYPE
SYNTAX INTEGER {
notInstalled (1),
commsOk (2),
commsLost (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The communications status of the sensor"
::= { pduExternalSensorStatusEntry 4 }
pduExternalSensorStatusState OBJECT-TYPE
SYNTAX INTEGER {
notPresent (0), alarmed (1), normal (2), belowLowerCritical (3), belowLowerWarning (4), aboveUpperWarning (5), aboveUpperCritical (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID reports the current state of the sensor.
A notPresent (0) response indicates that no sensor is attached.
An alarmed (1) response indicates that the sensor is present
and its measured reading indicates alarmed.
A normal (2) response indicates that the sensor is present
and its measured reading lies within all thresholds.
A belowLowerCritical (3) response indicates that the sensor
is present and its measured reading lies below the lower critical threshold.
A belowLowerWarning (4) response indicates that the sensor
is present and its measured reading lies below the lower warning threshold.
An aboveUpperWarning (5) response indicates that the sensor
is present and its measured reading lies above the upper warning threshold.
An aboveUpperCritical (6) response indicates that the sensor
is present and its measured reading lies above the upper critical threshold."
::= { pduExternalSensorStatusEntry 5 }
pduExternalSensorStatusValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor reading in pduExternalSensorConfigUnits value."
::= { pduExternalSensorStatusEntry 6 }
pduExternalSensorStatusTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sensor reading timestamp."
::= { pduExternalSensorStatusEntry 7 }
pduExternalSensorStatusHighPrecisionValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature sensor reading in tenths of pduExternalSensorConfigUnits value.
This OID is applied to temperature sensor only"
::= { pduExternalSensorStatusEntry 8 }
-- Start pduServerPing
pduServerPingTableSize OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Servers"
::= { pduServerPing 1 }
pduServerPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduServerPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Server Ping data"
::= { pduServerPing 2 }
pduServerPingEntry OBJECT-TYPE
SYNTAX PduServerPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Server Ping data from the server being queried.
The number of entries equals the value of pduServerPingTableSize."
INDEX { pduUnitConfigIndex, pduServerPingIndex }
::= { pduServerPingTable 1 }
PduServerPingEntry ::= SEQUENCE {
pduServerPingIndex
Integer32,
pduServerPingServerIPAddress
DisplayString,
pduServerPingEnabled
INTEGER
}
pduServerPingIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU pduServerPing table entry"
::= { pduServerPingEntry 1 }
pduServerPingServerIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address/host name of the server "
::= { pduServerPingEntry 2 }
pduServerPingEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0), true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Is ping enabled for this server?"
::= { pduServerPingEntry 3 }
-- Smart Cabinet
pduUnitSmartCabinetTableSize OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Smart Cabinet Configuration "
::= { pduSmartCabinet 1 }
pduUnitSmartCabinetTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduUnitSmartCabinetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Smart Cabinet information"
::= { pduSmartCabinet 2 }
pduUnitSmartCabinetEntry OBJECT-TYPE
SYNTAX PduUnitSmartCabinetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information of Smart Cabinet"
INDEX { pduUnitConfigIndex, pduUnitSmartCabinetIndex }
::= { pduUnitSmartCabinetTable 1 }
PduUnitSmartCabinetEntry ::= SEQUENCE {
pduUnitSmartCabinetIndex
Integer32,
pduUnitSmartCabinetCardUserName
DisplayString,
pduUnitSmartCabinetCardID
Integer32,
pduUnitSmartCabinetTimestamp
DisplayString,
pduUnitSmartCabinetDoor
Integer32
}
pduUnitSmartCabinetIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Smart Cabinet table entry"
::= { pduUnitSmartCabinetEntry 1 }
pduUnitSmartCabinetCardUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User name of ID card"
::= { pduUnitSmartCabinetEntry 2 }
pduUnitSmartCabinetCardID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Card ID."
::= { pduUnitSmartCabinetEntry 3 }
pduUnitSmartCabinetTimestamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time of information update"
::= { pduUnitSmartCabinetEntry 4 }
pduUnitSmartCabinetDoor OBJECT-TYPE
SYNTAX INTEGER {
HotAisle (1),
ColdAisle (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Aisle of Smart Cabinet. "
::= { pduUnitSmartCabinetEntry 5 }
pduUnitSmartCabinetControl OBJECT IDENTIFIER ::= { pduSmartCabinet 3 }
pduUnitSmartCabinetControlUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User name of ID card"
::= { pduUnitSmartCabinetControl 1 }
pduUnitSmartCabinetControlCardID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Card ID."
::= { pduUnitSmartCabinetControl 2 }
pduUnitSmartCabinetControlTimestamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the date and time of information update"
::= { pduUnitSmartCabinetControl 3 }
pduUnitSmartCabinetControlDoor OBJECT-TYPE
SYNTAX INTEGER {
HotAisle (1),
ColdAisle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aisle of Smart Cabinet. "
::= { pduUnitSmartCabinetControl 4 }
pduUnitSmartCabinetCardIDEdit OBJECT-TYPE
SYNTAX INTEGER {
grant (0), remove (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Smart Cabinet edit CardID "
::= { pduUnitSmartCabinetControl 5 }
pduUnitSmartCabinetColdAisleLockState OBJECT-TYPE
SYNTAX INTEGER {
unlock (0), lock (1), notPresent (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Smart Cabinet ColdAisle lock state "
::= { pduUnitSmartCabinetControl 6 }
pduUnitSmartCabinetHotAisleLockState OBJECT-TYPE
SYNTAX INTEGER {
unlock (0), lock (1), notPresent (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Smart Cabinet HotAisle lock state "
::= { pduUnitSmartCabinetControl 7 }
-- Traps Information
trapsInfo OBJECT IDENTIFIER ::= { pduTraps 1 }
trapsInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Trap Information entries. The number of
entries are given by the value of pduUnitTableSize."
::= { trapsInfo 1 }
trapsInfoEntry OBJECT-TYPE
SYNTAX TrapsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects used in traps"
INDEX { trapsInfoIndex }
::= { trapsInfoTable 1 }
TrapsInfoEntry ::= SEQUENCE {
trapsInfoIndex
Integer32,
userName
DisplayString,
userUpdated
DisplayString,
firmwareVersion
DisplayString,
roleUpdated
DisplayString,
smtpRecipients
DisplayString,
smtpServer
DisplayString
}
trapsInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the traps table entry"
::= { trapsInfoEntry 1 }
userName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user currently logged in."
::= { trapsInfoEntry 2 }
userUpdated OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user added, deleted, or modified."
::= { trapsInfoEntry 3 }
firmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of Firmware."
::= { trapsInfoEntry 4 }
roleUpdated OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The role added, deleted, or modified."
::= { trapsInfoEntry 5 }
smtpRecipients OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Comma separated list of SMTP recipients"
::= { trapsInfoEntry 6 }
smtpServer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address/host name of the SMTP server"
::= { trapsInfoEntry 7 }
pduIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique value for PDU. Its value ranges between 1
and the value of PDU count"
::= { trapsInfo 2 }
externalSensorIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique value for each sensor. Its value ranges between 1
and the value of external sensor count."
::= { trapsInfo 3 }
serverPing OBJECT-TYPE
SYNTAX INTEGER {
pingEnable (1),
pingDisable (2),
serverReachable (3),
serverNotReachable (4)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Whether server ping has been enabled or disabled and
whether the server is reachable or not reachable"
::= { trapsInfo 4 }
usbDevice OBJECT-TYPE
SYNTAX INTEGER {
connected (1),
disconnected (2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Whether a USB device has been connected or disconnected"
::= { trapsInfo 5 }
errorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Description of the Error"
::= { trapsInfo 6 }
daisyChain OBJECT-TYPE
SYNTAX INTEGER {
connected (1),
disconnected (2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Whether a daisy chain member has been connected or disconnected"
::= { trapsInfo 7 }
systemCommunication OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
lost (2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Whether the Network management card has lost contact with daisy a chain member."
::= { trapsInfo 8 }
networkCardStart NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The network card has started"
::= { pduTraps 2 }
networkCardReset NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The network card was reset via the web or command line interface."
::= { pduTraps 3 }
userLogin NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user logged in"
::= { pduTraps 4 }
userLogoff NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
" A user logged off"
::= { pduTraps 5 }
userAuthenticationFailed NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user authentication attempt failed."
::= { pduTraps 6 }
userSessionTimeout NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user session timed out"
::= { pduTraps 7 }
userAdded NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
userUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user account was added to system."
::= { pduTraps 8 }
userModified NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
userUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user account was modified."
::= { pduTraps 9 }
userDeleted NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
userUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user account was deleted."
::= { pduTraps 10 }
roleAdded NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
roleUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user role was added."
::= { pduTraps 11 }
roleModified NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
roleUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user role was modified."
::= { pduTraps 12 }
roleDeleted NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
roleUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user role was deleted."
::= { pduTraps 13 }
firmwareUpdateStarted NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
firmwareVersion,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A firmware update has started."
::= { pduTraps 14 }
firmwareUpdateCompleted NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
firmwareVersion,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The firmware update has completed."
::= { pduTraps 15 }
userBlocked NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user is blocked."
::= { pduTraps 16 }
outletControl NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduOutletSwitchedControlNumber,
pduOutletSwitchedStatusState,
pduOutletSwitchedControlCommand,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Outlet control operation applied."
::= { pduTraps 17 }
userPasswordChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
userUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user password was changed. "
::= { pduTraps 18 }
passwordSettingsChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"One or more password policy settings were changed."
::= { pduTraps 19 }
logFileCleared NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The log file has been cleared."
::= { pduTraps 21 }
pduConfigurationFileImported NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU configuration file was imported."
::= { pduTraps 22 }
pduConfigurationFileExported NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU configuration file was exported"
::= { pduTraps 23 }
pduUnitActivePowerStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitStatusLoadState,
pduUnitStatusActivePower,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU unit active power state changes."
::= { pduTraps 24 }
pduInputphaseVoltageStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduInputPhaseStatusCount,
pduInputPhaseStatusVoltageState,
pduInputPhaseStatusVoltage,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU input phase voltage state changes."
::= { pduTraps 25 }
pduInputphaseCurrentStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduInputPhaseStatusCount,
pduInputPhaseStatusCurrentState,
pduInputPhaseStatusCurrent,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU input phase Current state changes."
::= { pduTraps 26 }
pduCircuitBreakerCurrentStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduCircuitBreakerStatusIndex,
pduCircuitBreakerStatusLoadState,
pduCircuitBreakerStatusCurrent,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU Circuit Breaker Current state changes."
::= { pduTraps 27 }
pduOutletActivePowerStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduOutletMeteredStatusIndex,
pduOutletMeteredStatusLoadState,
pduOutletMeteredStatusActivePower,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU Metered Outlet Active Power state changes."
::= { pduTraps 28 }
pduExternalSensorStateChange NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduExternalSensorStatusIndex,
pduExternalSensorStatusName,
pduExternalSensorNamePlateType,
pduExternalSensorStatusAisle,
pduExternalSensorNamePlateUnits,
pduExternalSensorStatusState,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU External Sensor state changes."
::= { pduTraps 29 }
smtpTransmissionFailure NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
smtpRecipients,
smtpServer,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"SMTP message transmission failed."
::= { pduTraps 30 }
ldapError NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
errorDescription,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A LDAP error occurred"
::= { pduTraps 31 }
firmwareUpdateFailed NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
firmwareVersion,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A firmware update has failed."
::= { pduTraps 32 }
serverPingState NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
userName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduServerPingServerIPAddress,
serverPing,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The Ping feature has been enabled."
::= { pduTraps 33 }
bootloaderState NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Enter into Bootloader mode"
::= { pduTraps 34 }
daisyChainState NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
daisyChain,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A daisy chain member has been connected or disconnected."
::= { pduTraps 35 }
systemInternalCommunicationLost NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
systemCommunication,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Network management card has lost contaction with internal boards."
::= { pduTraps 36 }
SmartCabinetLockUnlocked NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitSmartCabinetDoor,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The Cabinet lock is unlocked."
::= { pduTraps 37 }
SmartCabinetLockLocked NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitSmartCabinetDoor,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The Cabinet lock is locked"
::= { pduTraps 38 }
SmartCabinetSwapCard NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitSmartCabinetDoor,
pduUnitSmartCabinetCardID,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Card is swapped"
::= { pduTraps 39 }
SmartCabinetLockerLockDoorOpen NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitSmartCabinetDoor,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Locker locked but door open"
::= { pduTraps 40 }
SmartCabinetLockerUnlockDoorClose NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
pduUnitSmartCabinetDoor,
pduExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"Locker unlocked but door close"
::= { pduTraps 41 }
systemReboot NOTIFICATION-TYPE
OBJECTS { pduIndex,
pduNamePlateName,
pduNamePlateInetAddressType,
pduNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"System has rebooted"
::= { pduTraps 50 }
esp OBJECT IDENTIFIER ::= { enlogic 2 }
espNamePlate OBJECT IDENTIFIER ::= { esp 1 }
espUnit OBJECT IDENTIFIER ::= { esp 2 }
espInputPhase OBJECT IDENTIFIER ::= { esp 3 }
espCircuitBreaker OBJECT IDENTIFIER ::= { esp 4 }
espExternalSensor OBJECT IDENTIFIER ::= { esp 6 }
espTraps OBJECT IDENTIFIER ::= { esp 9 }
-- Start espNamePlate
-- espNamePlateTable
espNamePlateTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of es PDU nameplate data"
::= { espNamePlate 2 }
espNamePlateEntry OBJECT-TYPE
SYNTAX EspNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Nameplate data from the PDU being queried. The numbers of entries equals the value of espNamePlateTableSize."
INDEX { espNamePlateIndex }
::= { espNamePlateTable 1 }
EspNamePlateEntry ::= SEQUENCE {
espNamePlateIndex
Integer32,
espNamePlateName
DisplayString,
espNamePlateLocation
DisplayString,
espNamePlateInetAddressType
InetAddressType,
espNamePlateIPAddress
InetAddress,
espNamePlateInetNetMask
InetAddress,
espNamePlateInetGateway
InetAddress,
espNamePlateMACAddress
MacAddress,
espNamePlateUTCTimeOffset
DisplayString,
espNamePlateModelNumber
DisplayString,
espNamePlateSerialNumber
DisplayString,
espNamePlateDateofManufacture
DisplayString,
espNamePlateFirmwareVersion
DisplayString,
espNamePlateFirmwareVersionTimeStamp
DisplayString,
espNamePlateType
INTEGER
}
espNamePlateIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the es PDU nameplate table entry"
::= { espNamePlateEntry 1 }
espNamePlateName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the es PDU"
::= { espNamePlateEntry 2 }
espNamePlateLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the location of PDU"
::= { espNamePlateEntry 3 }
espNamePlateInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of address format"
::= { espNamePlateEntry 4 }
espNamePlateIPAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address. A value of 0.0.0.0 indicates an error or an unset option"
::= { espNamePlateEntry 5 }
espNamePlateInetNetMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current netmask. A value of 0.0.0.0 indiates an error or an unset option"
::= { espNamePlateEntry 6 }
espNamePlateInetGateway OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current gateway. A value of 0.0.0.0 indicates an error or an unset option"
::= { espNamePlateEntry 7 }
espNamePlateMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The assigned MAC address for the PDU"
::= { espNamePlateEntry 8 }
espNamePlateUTCTimeOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The difference in hours and minutes from Coordinated Universal
Time(UTC) for the time used in a particular time zone"
::= { espNamePlateEntry 9 }
espNamePlateModelNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU model number"
::= { espNamePlateEntry 10 }
espNamePlateSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU serial number"
::= { espNamePlateEntry 11 }
espNamePlateDateofManufacture OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date the PDU was manufactured in mm/dd/yyyy format"
::= { espNamePlateEntry 12 }
espNamePlateFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU firmware version"
::= { espNamePlateEntry 13 }
espNamePlateFirmwareVersionTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of when the PDU firmware was last updated"
::= { espNamePlateEntry 14 }
espNamePlateType OBJECT-TYPE
SYNTAX INTEGER {
pdu (0),
inlineMeter (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Unit, PDU or Inline Meter"
::= { espNamePlateEntry 15 }
-- Start espUnit
espUnitConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspUnitConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU configuration data"
::= { espUnit 2 }
espUnitConfigEntry OBJECT-TYPE
SYNTAX EspUnitConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration data from the PDU being queried. The number of entries equals the value of espUnitTableSize"
INDEX { espUnitConfigIndex }
::= { espUnitConfigTable 1 }
EspUnitConfigEntry ::= SEQUENCE {
espUnitConfigIndex
Integer32,
espUnitConfigName
DisplayString,
espUnitConfigLocation
DisplayString,
espUnitConfigEnergyReset
INTEGER,
espUnitConfigResetNetworkManagementCard
INTEGER
}
espUnitConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Unit Config Entry"
::= { espUnitConfigEntry 1 }
espUnitConfigName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { espUnitConfigEntry 2 }
espUnitConfigLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user-defined string identifying the location of the PDU"
::= { espUnitConfigEntry 3 }
espUnitConfigEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2),
notSupported (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not support this feature will respond to this OID with a
value of notSupported (3). Attempts to set this OID in these models will fail. "
::= { espUnitConfigEntry 15 }
espUnitConfigResetNetworkManagementCard OBJECT-TYPE
SYNTAX INTEGER {
noOperation (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC."
::= { espUnitConfigEntry 20 }
espUnitPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspUnitPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU properties"
::= { espUnit 3 }
espUnitPropertiesEntry OBJECT-TYPE
SYNTAX EspUnitPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unit properties entry containing objects for a particular unit."
INDEX { espUnitPropertiesIndex }
::= { espUnitPropertiesTable 1 }
EspUnitPropertiesEntry ::= SEQUENCE {
espUnitPropertiesIndex
Integer32,
espUnitPropertiesName
DisplayString,
espUnitPropertiesOutletCount
Integer32,
espUnitPropertiesSwitchedOutletCount
Integer32,
espUnitPropertiesMeteredOutletCount
Integer32,
espUnitPropertiesInputPhaseCount
Integer32,
espUnitPropertiesCircuitBreakerCount
Integer32,
espUnitPropertiesMaxExternalSensorCount
Integer32,
espUnitPropertiesConnExternalSensorCount
Integer32,
espUnitPropertiesRatedVoltage
DisplayString,
espUnitPropertiesRatedMaxCurrent
DisplayString,
espUnitPropertiesRatedFrequency
DisplayString,
espUnitPropertiesRatedPower
DisplayString
}
espUnitPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU properties table entry"
::= { espUnitPropertiesEntry 1 }
espUnitPropertiesName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { espUnitPropertiesEntry 2 }
espUnitPropertiesOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of outlets on the PDU"
::= { espUnitPropertiesEntry 3 }
espUnitPropertiesSwitchedOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of switched outlets on the PDU"
::= { espUnitPropertiesEntry 4 }
espUnitPropertiesMeteredOutletCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of metered outlets on the PDU"
::= { espUnitPropertiesEntry 5 }
espUnitPropertiesInputPhaseCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of phases on the PDU"
::= { espUnitPropertiesEntry 6 }
espUnitPropertiesCircuitBreakerCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of circuit breaker on the PDU"
::= { espUnitPropertiesEntry 7 }
espUnitPropertiesMaxExternalSensorCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of external sensors that can be connected to the PDU"
::= { espUnitPropertiesEntry 8 }
espUnitPropertiesConnExternalSensorCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of external sensors connected to the PDU"
::= { espUnitPropertiesEntry 9 }
espUnitPropertiesRatedVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU voltage rating in Volts"
::= { espUnitPropertiesEntry 10 }
espUnitPropertiesRatedMaxCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU current rating in Amps"
::= { espUnitPropertiesEntry 11 }
espUnitPropertiesRatedFrequency OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU frequency rating in Hz"
::= { espUnitPropertiesEntry 12 }
espUnitPropertiesRatedPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PDU VA (VoltAmps) rating."
::= { espUnitPropertiesEntry 13 }
espUnitStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspUnitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU status information"
::= { espUnit 4 }
espUnitStatusEntry OBJECT-TYPE
SYNTAX EspUnitStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status information from the PDU being queried"
INDEX { espUnitStatusIndex }
::= { espUnitStatusTable 1 }
EspUnitStatusEntry ::= SEQUENCE {
espUnitStatusIndex
Integer32,
espUnitStatusName
DisplayString,
espUnitStatusLoadState
INTEGER,
espUnitStatusActivePower
Integer32,
espUnitStatusApparentPower
Integer32,
espUnitStatusEnergy
Integer32,
espUnitStatusResettableEnergy
Integer32,
espUnitStatusEnergyStartTime
DisplayString
}
espUnitStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU status table entry"
::= { espUnitStatusEntry 1 }
espUnitStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the PDU"
::= { espUnitStatusEntry 2 }
espUnitStatusLoadState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the present load status of the PDU based on Active Power."
::= { espUnitStatusEntry 3 }
espUnitStatusActivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Watts(W),
of the PDU being queried."
::= { espUnitStatusEntry 4 }
espUnitStatusApparentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Volt-Amps(VA)
of the PDU load being queried."
::= { espUnitStatusEntry 5 }
espUnitStatusEnergy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime."
::= { espUnitStatusEntry 9 }
espUnitStatusResettableEnergy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user resettable energy meter measuring PDU energy consumption
in tenths of kilowatt-hours(kWh)."
::= { espUnitStatusEntry 10 }
espUnitStatusEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time of the last device energy meter reset"
::= { espUnitStatusEntry 11 }
-- Start espInputPhase
espInputPhaseConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspInputPhaseConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Input Phase configuration data"
::= { espInputPhase 2 }
espInputPhaseConfigEntry OBJECT-TYPE
SYNTAX EspInputPhaseConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An input phase entry containing objects for a particular input phase."
INDEX { espUnitConfigIndex, espInputPhaseConfigIndex }
::= { espInputPhaseConfigTable 1 }
EspInputPhaseConfigEntry ::= SEQUENCE {
espInputPhaseConfigIndex
Integer32,
espInputPhaseConfigCount
Integer32
}
espInputPhaseConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Input Phase configuration table entry"
::= { espInputPhaseConfigEntry 1 }
espInputPhaseConfigCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Input Phases"
::= { espInputPhaseConfigEntry 2 }
espInputPhaseStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspInputPhaseStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Input Phase status data"
::= { espInputPhase 4 }
espInputPhaseStatusEntry OBJECT-TYPE
SYNTAX EspInputPhaseStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An input phase status entry containing objects for a particular input phase."
INDEX { espUnitStatusIndex, espInputPhaseStatusIndex }
::= { espInputPhaseStatusTable 1 }
EspInputPhaseStatusEntry ::= SEQUENCE {
espInputPhaseStatusIndex
Integer32,
espInputPhaseStatusCount
Integer32,
espInputPhaseStatusCurrentState
INTEGER,
espInputPhaseStatusVoltageState
INTEGER,
espInputPhaseStatusCurrent
Integer32,
espInputPhaseStatusVoltage
Integer32,
espInputPhaseStatusActivePower
Integer32,
espInputPhaseStatusApparentPower
Integer32,
espInputPhaseStatusPowerFactor
Integer32
}
espInputPhaseStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Input Phase status entry"
::= { espInputPhaseStatusEntry 1 }
espInputPhaseStatusCount OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Input Phase ID"
::= { espInputPhaseStatusEntry 2 }
espInputPhaseStatusCurrentState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present current status of the PDU Input Phase being queried"
::= { espInputPhaseStatusEntry 3 }
espInputPhaseStatusVoltageState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present voltage status of the PDU Input Phase being queried"
::= { espInputPhaseStatusEntry 4 }
espInputPhaseStatusCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current draw, in hundredths of Amps(A), of the load on the
PDU Input Phase being queried."
::= { espInputPhaseStatusEntry 5 }
espInputPhaseStatusVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the voltage, in Volts(V), of the PDU Input Phase being queried."
::= { espInputPhaseStatusEntry 6 }
espInputPhaseStatusActivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Watts(W),
consumed on the PDU Input Phase being queried."
::= { espInputPhaseStatusEntry 7 }
espInputPhaseStatusApparentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns power consumption, in Volt-Amps(VA),
of the PDU Input Phase being queried."
::= { espInputPhaseStatusEntry 8 }
espInputPhaseStatusPowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the ratio of active to apparent power of the PDU Input Phase being queried."
::= { espInputPhaseStatusEntry 9 }
-- Start espCircuitBreaker
espCircuitBreakerConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspCircuitBreakerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU Circuit Breaker configuration data"
::= { espCircuitBreaker 2 }
espCircuitBreakerConfigEntry OBJECT-TYPE
SYNTAX EspCircuitBreakerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker configuration entry containing objects for a particular circuit breaker."
INDEX { espUnitConfigIndex, espCircuitBreakerConfigIndex }
::= { espCircuitBreakerConfigTable 1 }
EspCircuitBreakerConfigEntry ::= SEQUENCE {
espCircuitBreakerConfigIndex
Integer32,
espCircuitBreakerConfigCount
Integer32,
espCircuitBreakerName
DisplayString
}
espCircuitBreakerConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker configuration table entry"
::= { espCircuitBreakerConfigEntry 1 }
espCircuitBreakerConfigCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of circuit breakers on the PDU"
::= { espCircuitBreakerConfigEntry 2 }
espCircuitBreakerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label of the circuit breaker"
::= { espCircuitBreakerConfigEntry 3 }
espCircuitBreakerPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspCircuitBreakerPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU circuit breaker properties"
::= { espCircuitBreaker 3 }
espCircuitBreakerPropertiesEntry OBJECT-TYPE
SYNTAX EspCircuitBreakerPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker properties entry containing objects for a particular circuit breaker."
INDEX { espUnitPropertiesIndex, espCircuitBreakerPropertiesIndex }
::= { espCircuitBreakerPropertiesTable 1 }
EspCircuitBreakerPropertiesEntry ::= SEQUENCE {
espCircuitBreakerPropertiesIndex
Integer32,
espCircuitBreakerPropertiesCount
Integer32,
espCircuitBreakerPropertiesInputLayout
INTEGER
}
espCircuitBreakerPropertiesIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker properties table entry"
::= { espCircuitBreakerPropertiesEntry 1 }
espCircuitBreakerPropertiesCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Circuit Breakers"
::= { espCircuitBreakerPropertiesEntry 2 }
espCircuitBreakerPropertiesInputLayout OBJECT-TYPE
SYNTAX INTEGER {
seqPhase1ToNeutral (1),
seqPhase2ToNeutral (2),
seqPhase3ToNeutral (3),
seqPhase1ToPhase2 (4),
seqPhase2ToPhase3 (5),
seqPhase3ToPhase1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID describes the outlet phase connections on
the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets attached
to circuit breaker are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that outlets attached
to circuit breaker are connected from Phase 2 to Neutral.
seqPhase3ToNeutral(3) indicates that outlets attached
to circuit breaker are connected from Phase 3 to Neutral.
seqPhase1ToPhase2(4) indicates that outlets attached
to circuit breaker are connected from Phase 1 to Phase2.
seqPhase2ToPhase3(5) indicates that outlets attached
to circuit breaker are connected from Phase 2 to Phase3.
seqPhase3ToPhase1(6) indicates that outlets attached
to circuit breaker are connected from Phase 3 to Phase1. "
::= { espCircuitBreakerPropertiesEntry 3 }
espCircuitBreakerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspCircuitBreakerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU circuit breaker status data"
::= { espCircuitBreaker 4 }
espCircuitBreakerStatusEntry OBJECT-TYPE
SYNTAX EspCircuitBreakerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A circuit breaker status entry containing objects for a particular circuit breaker."
INDEX { espUnitStatusIndex, espCircuitBreakerStatusIndex }
::= { espCircuitBreakerStatusTable 1 }
EspCircuitBreakerStatusEntry ::= SEQUENCE {
espCircuitBreakerStatusIndex
Integer32,
espCircuitBreakerStatusCount
Integer32,
espCircuitBreakerLabel
DisplayString,
espCircuitBreakerStatusLoadState
INTEGER,
espCircuitBreakerStatusCurrent
Integer32
}
espCircuitBreakerStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU Circuit Breaker status table entry"
::= { espCircuitBreakerStatusEntry 1 }
espCircuitBreakerStatusCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Circuit Breakers"
::= { espCircuitBreakerStatusEntry 2 }
espCircuitBreakerLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label on the PDU identifying the circuit breaker"
::= { espCircuitBreakerStatusEntry 3 }
espCircuitBreakerStatusLoadState OBJECT-TYPE
SYNTAX INTEGER {
upperCritical (1),
upperWarning (2),
lowerWarning (3),
lowerCritical (4),
normal (5),
off (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the present load status of the PDU Circuit
Breaker being queried"
::= { espCircuitBreakerStatusEntry 4 }
espCircuitBreakerStatusCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current draw, in hundredths of Amps(A), of the load on
the PDU Circuit Breaker being queried."
::= { espCircuitBreakerStatusEntry 5 }
-- Start espExternalSensor
espExternalSensorNamePlateTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspExternalSensorNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU ExternalSensorNamePlate data"
::= { espExternalSensor 2 }
espExternalSensorNamePlateEntry OBJECT-TYPE
SYNTAX EspExternalSensorNamePlateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"External Sensor Name Plate data from the external
sensor being queried. The number of entries equals
the value of espExternalSensorNamePlateTableSize."
INDEX { espNamePlateIndex, espExternalSensorNamePlateIndex }
::= { espExternalSensorNamePlateTable 1 }
EspExternalSensorNamePlateEntry ::= SEQUENCE {
espExternalSensorNamePlateIndex
Integer32,
espExternalSensorNamePlateName
DisplayString,
espExternalSensorNamePlateSerialNumber
DisplayString,
espExternalSensorNamePlateType
INTEGER,
espExternalSensorNamePlateUnits
INTEGER
}
espExternalSensorNamePlateIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor status table entry"
::= { espExternalSensorNamePlateEntry 1 }
espExternalSensorNamePlateName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user-defined string identifying the external sensor"
::= { espExternalSensorNamePlateEntry 2 }
espExternalSensorNamePlateSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the external sensor being queried"
::= { espExternalSensorNamePlateEntry 5 }
espExternalSensorNamePlateType OBJECT-TYPE
SYNTAX INTEGER {
temperature (1),
humidity (2),
doorSwitch (3),
dryContact (4),
spotFluid (5),
ropeFluid (6),
smoke (7),
beacon (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of external sensor."
::= { espExternalSensorNamePlateEntry 6 }
espExternalSensorNamePlateUnits OBJECT-TYPE
SYNTAX INTEGER {
logic (0),
degreeC (1),
degreeF (2),
percent (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The base units the external sensor is measured in.
This parameter does not apply to onOff, trip, vibration,
waterDetection, smokeDetection sensors. "
::= { espExternalSensorNamePlateEntry 7 }
espExternalSensorConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspExternalSensorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU External Sensor configuration data"
::= { espExternalSensor 3 }
espExternalSensorConfigEntry OBJECT-TYPE
SYNTAX EspExternalSensorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration data from the PDU External
Sensor being queried"
INDEX { espUnitConfigIndex, espExternalSensorConfigIndex }
::= { espExternalSensorConfigTable 1 }
EspExternalSensorConfigEntry ::= SEQUENCE {
espExternalSensorConfigIndex
Integer32,
espExternalSensorConfigAlarmState
INTEGER
}
espExternalSensorConfigIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor
configuration table entry"
::= { espExternalSensorConfigEntry 1 }
espExternalSensorConfigAlarmState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined alarm state of external sensor"
::= { espExternalSensorConfigEntry 9 }
espExternalSensorStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EspExternalSensorStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PDU External Sensor status data"
::= { espExternalSensor 4 }
espExternalSensorStatusEntry OBJECT-TYPE
SYNTAX EspExternalSensorStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status data from the PDU External Sensor
being queried"
INDEX { espUnitStatusIndex, espExternalSensorStatusIndex }
::= { espExternalSensorStatusTable 1 }
EspExternalSensorStatusEntry ::= SEQUENCE {
espExternalSensorStatusIndex
Integer32,
espExternalSensorStatusName
DisplayString,
espExternalSensorStatusAisle
INTEGER,
espExternalSensorStatusCommStatus
INTEGER,
espExternalSensorStatusState
INTEGER,
espExternalSensorStatusValue
Integer32,
espExternalSensorStatusHighPrecisionValue
Integer32
}
espExternalSensorStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the PDU External Sensor status table entry"
::= { espExternalSensorStatusEntry 1 }
espExternalSensorStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined name for the External Sensor"
::= { espExternalSensorStatusEntry 2 }
espExternalSensorStatusAisle OBJECT-TYPE
SYNTAX INTEGER {
hotAisle (1),
coldAisle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the external sensor is
in a hot or cold aisle"
::= { espExternalSensorStatusEntry 3 }
espExternalSensorStatusCommStatus OBJECT-TYPE
SYNTAX INTEGER {
notInstalled (1),
commsOk (2),
commsLost (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The communications status of the sensor"
::= { espExternalSensorStatusEntry 4 }
espExternalSensorStatusState OBJECT-TYPE
SYNTAX INTEGER {
notPresent (0), alarmed (1), normal (2), belowLowerCritical (3), belowLowerWarning (4), aboveUpperWarning (5), aboveUpperCritical (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This OID reports the current state of the sensor.
A notPresent (0) response indicates that no sensor is attached.
An alarmed (1) response indicates that the sensor is present
and its measured reading indicates alarmed.
A normal (2) response indicates that the sensor is present
and its measured reading lies within all thresholds.
A belowLowerCritical (3) response indicates that the sensor
is present and its measured reading lies below the lower critical threshold.
A belowLowerWarning (4) response indicates that the sensor
is present and its measured reading lies below the lower warning threshold.
An aboveUpperWarning (5) response indicates that the sensor
is present and its measured reading lies above the upper warning threshold.
An aboveUpperCritical (6) response indicates that the sensor
is present and its measured reading lies above the upper critical threshold."
::= { espExternalSensorStatusEntry 5 }
espExternalSensorStatusValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor reading in espExternalSensorConfigUnits value."
::= { espExternalSensorStatusEntry 6 }
espExternalSensorStatusHighPrecisionValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature sensor reading in tenths of espExternalSensorConfigUnits value.
This OID is applied to temperature sensor only"
::= { espExternalSensorStatusEntry 8 }
-- Traps Information
espTrapsInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the traps table entry"
::= { espTraps 1 }
espUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user currently logged in."
::= { espTraps 2 }
espFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of Firmware."
::= { espTraps 4 }
espIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique value for PDU. Its value ranges between 1
and the value of PDU count"
::= { espTraps 5 }
espExternalSensorIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique value for each sensor. Its value ranges between 1
and the value of external sensor count."
::= { espTraps 6 }
espErrorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Description of the Error"
::= { espTraps 7 }
espNetworkCardStart NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The network card has started"
::= { espTraps 8 }
espNetworkCardReset NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The network card was reset via the web or command line interface."
::= { espTraps 9}
espFirmwareUpdateCompleted NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
firmwareVersion,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The firmware update has completed."
::= { espTraps 10 }
espUserPasswordChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
userUpdated,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"A user password was changed. "
::= { espTraps 11 }
espLogFileCleared NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"The log file has been cleared."
::= { espTraps 12 }
espConfigurationFileExported NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU configuration file was exported"
::= { espTraps 13 }
espUnitActivePowerStateChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
espUnitStatusLoadState,
espUnitStatusActivePower,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU unit active power state changes."
::= { espTraps 14 }
espInputphaseVoltageStateChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
espInputPhaseStatusCount,
espInputPhaseStatusVoltageState,
espInputPhaseStatusVoltage,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU input phase voltage state changes."
::= { espTraps 15 }
espInputphaseCurrentStateChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
espInputPhaseStatusCount,
espInputPhaseStatusCurrentState,
espInputPhaseStatusCurrent,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU input phase Current state changes."
::= { espTraps 16 }
espCircuitBreakerCurrentStateChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
espCircuitBreakerStatusIndex,
espCircuitBreakerStatusLoadState,
espCircuitBreakerStatusCurrent,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU Circuit Breaker Current state changes."
::= { espTraps 17 }
espExternalSensorStateChange NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
espExternalSensorStatusIndex,
espExternalSensorStatusName,
espExternalSensorNamePlateType,
espExternalSensorStatusAisle,
espExternalSensorNamePlateUnits,
espExternalSensorStatusState,
espExternalSensorStatusValue,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU External Sensor state changes."
::= { espTraps 18 }
espConfigurationFileImported NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU configuration file was imported"
::= { espTraps 19 }
espNetworkUp NOTIFICATION-TYPE
OBJECTS { espIndex,
espNamePlateName,
userName,
espNamePlateInetAddressType,
espNamePlateIPAddress,
sysContact,
sysName,
sysLocation }
STATUS current
DESCRIPTION
"PDU Network is up "
::= { espTraps 20 }
END