CT-ELS10-MIB DEFINITIONS ::= BEGIN
-- SMC-MIB
-- Copyright 1999 Standard Microsystems Corporation. All Rights Reserved.
-- Reproduction of this document is authorized on condition that this
-- copyright notice is included. This Standard Microsystems Corporation
-- SNMP Management Information Base Specification (Specification) embodies
-- Standard Microsystems Corporation's proprietary intellectual property.
-- Standard Microsystems Corporation retains all title and ownership in
-- the Specification, including any revisions.
-- It is Standard Microsystems Corporation's intent to encourage the
-- widespread use of this Specification in connection with the management
-- of Standard Microsystems Corporation products. Standard Microsystems
-- Corporation grants vendors, end-users, and other interested parties a
-- non-exclusive license to use this Specification in connection with the
-- management of Standard Microsystems Corporation products.
-- This Specification is supplied "AS IS," and Standard Microsystems
-- Corporation makes no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString, sysObjectID, ifOutDiscards, ifInErrors, ifOutErrors,
PhysAddress
FROM RFC1213-MIB
Counter, Gauge, IpAddress, TimeTicks, enterprises
FROM RFC1155-SMI
dot1dStpDesignatedRoot, dot1dStpRootCost, dot1dStpRootPort,
dot1dStpMaxAge, dot1dStpHelloTime, dot1dStpForwardDelay,
dot1dStpPortDesignatedRoot, dot1dStpPortDesignatedBridge,
dot1dStpPortDesignatedCost, dot1dStpPortDesignatedPort,
dot1dStpPortState
FROM BRIDGE-MIB
TRAP-TYPE
FROM RFC-1215;
-- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
-- directory OBJECT IDENTIFIER ::= { internet 1 }
-- experimental OBJECT IDENTIFIER ::= { internet 3 }
-- private OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
sigma OBJECT IDENTIFIER ::= { enterprises 97 }
sys OBJECT IDENTIFIER ::= { sigma 1 }
els10-27 OBJECT IDENTIFIER ::= { sigma 9 }
els10-27hw OBJECT IDENTIFIER ::= { els10-27 1 }
els10-27sw OBJECT IDENTIFIER ::= { els10-27 2 }
els10-27admin OBJECT IDENTIFIER ::= { els10-27 3 }
els10-27swdis OBJECT IDENTIFIER ::= { els10-27 4 }
els10-27addr OBJECT IDENTIFIER ::= { els10-27 5 }
els10-27if OBJECT IDENTIFIER ::= { els10-27 6 }
els10-27dot3 OBJECT IDENTIFIER ::= { els10-27 7 }
els10-27uart OBJECT IDENTIFIER ::= { els10-27 8 }
els10-27debug OBJECT IDENTIFIER ::= { els10-27 10 }
els10-27lpbk OBJECT IDENTIFIER ::= { els10-27 11 }
els10-27proto OBJECT IDENTIFIER ::= { els10-27 12 }
els10-27trunk OBJECT IDENTIFIER ::= { els10-27 13 }
els10-27workgroup OBJECT IDENTIFIER ::= { els10-27 14 }
els10-27trapMgt OBJECT IDENTIFIER ::= { els10-27 15 }
els10-27pingMgt OBJECT IDENTIFIER ::= { els10-27 16 }
els10-27traceMgt OBJECT IDENTIFIER ::= { els10-27 17 }
els10-27volmirrorgroup OBJECT IDENTIFIER ::= { els10-27 19 }
els10-27VlanBridgeConfig OBJECT IDENTIFIER ::= { els10-27 20 }
els10-27volipmgroup OBJECT IDENTIFIER ::= { els10-27 21 }
els10-27voligmpgroup OBJECT IDENTIFIER ::= { els10-27 22 }
els10-27FlowControlCtl OBJECT IDENTIFIER ::= { els10-27 23 }
-- SMC MIB
-- System group
sysID OBJECT-TYPE
SYNTAX INTEGER {
els10-27-bridge(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { sys 1 }
sysReset OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { sys 2 }
sysTrapPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { sys 6 }
-- HW Configuration Group
els10-27hwDiagCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hw 1 }
els10-27hwManufData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hw 2 }
els10-27hwPortCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hw 3 }
els10-27hwPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxhwPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hw 4 }
els10-27hwPortEntry OBJECT-TYPE
SYNTAX LxhwPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27hwPortIndex }
::= { els10-27hwPortTable 1 }
LxhwPortEntry ::= SEQUENCE {
els10-27hwPortIndex
INTEGER,
els10-27hwPortType
INTEGER,
els10-27hwPortSubType
INTEGER,
els10-27hwPortDiagPassed
INTEGER,
els10-27hwAddr
OCTET STRING
}
els10-27hwPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hwPortEntry 1 }
els10-27hwPortType OBJECT-TYPE
SYNTAX INTEGER {
port-csma(1),
port-uart(6),
port-none(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hwPortEntry 2 }
els10-27hwPortSubType OBJECT-TYPE
SYNTAX INTEGER { csmacd-tpx(13),
csmacd-100-tpx(16),
csmacd-100-fx(17),
uart-female-9pin(80),
no-information(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hwPortEntry 3 }
els10-27hwPortDiagPassed OBJECT-TYPE
SYNTAX INTEGER { diag-passed(1), diag-failed(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hwPortEntry 4 }
els10-27hwAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27hwPortEntry 5 }
els10-27hwUpLink OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies whether the Up-Link I/O module is existed"
::= { els10-27hw 5 }
els10-27hwUpLinkManufData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a 32-byte array which contains the part number,
serial number, and hardware revision level of the Up-Link
I/O module. This array is valid only when the els10-27hwUplink
is true. If els10-27hwUplink is false, it returns an error"
::= { els10-27hw 6 }
-- LXSW Configuration Group
els10-27swNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27sw 1 }
els10-27swFilesetTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxswFilesetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27sw 2 }
els10-27swFilesetEntry OBJECT-TYPE
SYNTAX LxswFilesetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27swIndex }
::= { els10-27swFilesetTable 1 }
LxswFilesetEntry ::= SEQUENCE {
els10-27swIndex
INTEGER,
els10-27swDesc
DisplayString,
els10-27swCount
INTEGER,
els10-27swType
OCTET STRING,
els10-27swSizes
OCTET STRING,
els10-27swStarts
OCTET STRING,
els10-27swBases
OCTET STRING,
els10-27swFlashBank
INTEGER
}
els10-27swIndex OBJECT-TYPE
SYNTAX INTEGER {
currently-executing(1),
next-boot(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 1 }
els10-27swDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 2 }
els10-27swCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 3 }
els10-27swType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 4 }
els10-27swSizes OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 5 }
els10-27swStarts OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 6 }
els10-27swBases OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 7 }
els10-27swFlashBank OBJECT-TYPE
SYNTAX INTEGER {
first-bank(1),
second-bank(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27swFilesetEntry 8 }
-- LXADMIN Group
els10-27adminFatalErr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Information about last reset:
First byte, cause of reset, values:
00: power failure
01: WatchDog Timeout
02: Software Reset
03: NMS Shutdown
04-255: Fatal Error
Second byte, Hw/Sw component that failed
Remaining bytes, description of fault."
::= { els10-27admin 1 }
els10-27adminAnyPass OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 2 }
els10-27adminGetPass OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 3 }
els10-27adminNMSIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 4 }
els10-27adminStorageFailure OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 7 }
els10-27adminAuthenticationFailure OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 8 }
els10-27adminNAMReceiveCongests OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 10 }
els10-27adminArpEntries OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 11 }
els10-27adminArpStatics OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 12 }
els10-27adminArpOverflows OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 13 }
els10-27adminIpEntries OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 14 }
els10-27adminIpStatics OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 15 }
els10-27adminStaticPreference OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 16 }
els10-27adminRipPreference OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 17 }
els10-27adminRipRouteDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 18 }
els10-27adminRebootConfig OBJECT-TYPE
SYNTAX INTEGER {
no-change(1),
tftp-config(2),
revert-to-defaults(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 19 }
els10-27adminDisableButton OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 21 }
els10-27adminButtonSelection OBJECT-TYPE
SYNTAX INTEGER {
led-any-activity(1),
led-rx-activity(2),
led-tx-activity(3),
led-any-collision(4),
led-programmed(5),
led-duplex(6),
led-speed(7),
led-mirror(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 22 }
els10-27adminLEDProgramOption OBJECT-TYPE
SYNTAX INTEGER {
program-led-any-error(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27admin 23 }
-- Software Distribution Group
els10-27swdisDesc OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description (0-32 bytes) of the software set currently
being downloaded, or a description of the software set last
downloaded since the FN1026 booted."
::= { els10-27swdis 1 }
els10-27swdisAccess OBJECT-TYPE
SYNTAX INTEGER {
protected(1),
any-software(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The version of software that may be downloaded. Attempts to
download other versions of software will be rejected. The
value for swdisAccess is embedded within the software files
that are to be distributed via TFTP. Its value may be
derived from the names of the software files. the NMS operator
may wish to use the following special values:
protected (1) No software downloads will be accepted
any-software (2) A software download of any version of new
software will be accepted - this is the factory default"
::= { els10-27swdis 2 }
els10-27swdisWriteStatus OBJECT-TYPE
SYNTAX INTEGER {
in-progress(1),
success(2),
config-error(3),
flash-error(4),
config-and-flash-errors(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the erase/write operation."
::= { els10-27swdis 3 }
els10-27swdisConfigIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the NMS (i.e., any IP host) that is allowed
to use TFTP to send/retrieve the configuration file of the
FN1026. A value of 0.0.0.0 (which is the factory specified
default) prevents any NMS from obtaining access, while a
value of 255.255.255.255 gives every NMS permission."
::= { els10-27swdis 4 }
els10-27swdisConfigRetryTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds that the FN1026 will wait for an
acknowledgment before it retransmits an unacknowledged TFTP
data block. The factory specified default is 5 seconds."
::= { els10-27swdis 5 }
els10-27swdisConfigTotalTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds that the FN1026 will wait for an
acknowledgment to a data block before it cancels a TFTP
session. The factory specified default is 25 seconds."
::= { els10-27swdis 6 }
-- Address Configuration
els10-27addrStatics OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 1 }
els10-27addrDynamics OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 2 }
els10-27addrDynamicMax OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 3 }
els10-27addrDynamicOverflows OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 4 }
els10-27addrFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 5 }
els10-27addrMAC OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 6 }
els10-27addrPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 7 }
els10-27addrOperation OBJECT-TYPE
SYNTAX INTEGER {
read-random(1),
read-next(2),
update(4),
delete(5),
read-block(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 8 }
els10-27addrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 9 }
els10-27addrNext OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 10 }
els10-27addrBlockSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 19 }
els10-27addrBlock OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27addr 20 }
-- Interfaces Group
els10-27ifTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxifEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27if 1 }
els10-27ifEntry OBJECT-TYPE
SYNTAX LxifEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27ifIndex }
::= { els10-27ifTable 1 }
LxifEntry ::= SEQUENCE {
els10-27ifIndex
INTEGER,
---els10-27ifRxCnt
--- INTEGER,
---els10-27ifTxCnt
--- INTEGER,
els10-27ifThreshold
INTEGER,
els10-27ifThresholdTime
INTEGER,
els10-27ifRxQueueThresh
INTEGER,
els10-27ifRxQueueThreshTime
INTEGER,
els10-27ifTxStormCnt
INTEGER,
els10-27ifTxStormTime
TimeTicks,
els10-27ifFunction
INTEGER,
els10-27ifRxHwFCSs
Counter,
els10-27ifRxQueues
Counter,
els10-27ifStatisticsTime
TimeTicks,
els10-27ifForwardedChars
Counter,
els10-27ifDescr
DisplayString,
els10-27ifGoodRxFrames
Counter,
els10-27ifGoodTxFrames
Counter
}
els10-27ifIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 1 }
--- els10-27ifRxCnt OBJECT-TYPE
--- SYNTAX INTEGER
--- ACCESS read-only
--- STATUS mandatory
--- DESCRIPTION
--- " "
--- ::= { els10-27ifEntry 2 }
--- els10-27ifTxCnt OBJECT-TYPE
--- SYNTAX INTEGER
--- ACCESS read-only
--- STATUS mandatory
--- DESCRIPTION
--- " "
--- ::= { els10-27ifEntry 3 }
els10-27ifThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 4 }
els10-27ifThresholdTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 5 }
els10-27ifRxQueueThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 6 }
els10-27ifRxQueueThreshTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 7 }
els10-27ifTxStormCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 8 }
els10-27ifTxStormTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 9 }
els10-27ifFunction OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 16 }
els10-27ifRxHwFCSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 18 }
els10-27ifRxQueues OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 19 }
els10-27ifStatisticsTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 27 }
els10-27ifForwardedChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 28 }
els10-27ifDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 29 }
els10-27ifGoodRxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 30 }
els10-27ifGoodTxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27ifEntry 31 }
-- Dot3 Group
els10-27dot3Table OBJECT-TYPE
SYNTAX SEQUENCE OF Lxdot3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3 1 }
els10-27dot3Entry OBJECT-TYPE
SYNTAX Lxdot3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27dot3Index }
::= { els10-27dot3Table 1 }
Lxdot3Entry ::= SEQUENCE {
els10-27dot3Index
INTEGER,
els10-27dot3TPLinkOK
INTEGER,
els10-27dot3LedOn
INTEGER,
els10-27dot3RxCollisions
Counter,
els10-27dot3RxRunts
Counter,
els10-27dot3RxLateColls
Counter,
els10-27dot3TxJabbers
Counter,
els10-27dot3TxBabbles
Counter,
els10-27dot3TxCollisions
Counter,
els10-27dot3SpeedSelection
INTEGER,
els10-27dot3DuplexSelection
INTEGER
}
els10-27dot3Index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 1 }
els10-27dot3TPLinkOK OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 2 }
els10-27dot3LedOn OBJECT-TYPE
SYNTAX INTEGER { led-on(1), led-off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 3 }
els10-27dot3RxCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 4 }
els10-27dot3RxRunts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 5 }
els10-27dot3RxLateColls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 6 }
els10-27dot3TxJabbers OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 7 }
els10-27dot3TxBabbles OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 8 }
els10-27dot3TxCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 9 }
els10-27dot3SpeedSelection OBJECT-TYPE
SYNTAX INTEGER { speed-10mbit(1), speed-100mbit(2), speed-auto(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 13 }
els10-27dot3DuplexSelection OBJECT-TYPE
SYNTAX INTEGER { duplex-auto(1), duplex-half(2), duplex-full(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27dot3Entry 14 }
-- UART Interface Group
els10-27uartTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxuartEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27uart 1 }
els10-27uartEntry OBJECT-TYPE
SYNTAX LxuartEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27uartIndex }
::= { els10-27uartTable 1 }
LxuartEntry ::= SEQUENCE {
els10-27uartIndex
INTEGER,
els10-27uartBaud
INTEGER,
els10-27uartAlignmentErrors
Counter,
els10-27uartOverrunErrors
Counter
}
els10-27uartIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27uartEntry 1 }
els10-27uartBaud OBJECT-TYPE
SYNTAX INTEGER {
b2400-baud(3),
b4800-baud(4),
b9600-baud(5),
b19200-baud(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27uartEntry 2 }
els10-27uartAlignmentErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27uartEntry 3 }
els10-27uartOverrunErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27uartEntry 4 }
-- Debug Command Group
els10-27debugStringID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debug 1 }
els10-27debugString OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debug 2 }
els10-27debugTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxdebugEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debug 3 }
els10-27debugEntry OBJECT-TYPE
SYNTAX LxdebugEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27debugIndex }
::= { els10-27debugTable 1 }
LxdebugEntry ::= SEQUENCE {
els10-27debugIndex
INTEGER,
els10-27debugOperation
INTEGER,
els10-27debugBase
INTEGER,
els10-27debugLength
INTEGER,
els10-27debugData
OCTET STRING
}
els10-27debugIndex OBJECT-TYPE
SYNTAX INTEGER {
debug-nam(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debugEntry 1 }
els10-27debugOperation OBJECT-TYPE
SYNTAX INTEGER {
examine(1),
modify(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debugEntry 2 }
els10-27debugBase OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debugEntry 3 }
els10-27debugLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debugEntry 4 }
els10-27debugData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27debugEntry 5 }
-- Loopback Command Group
els10-27lpbkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxlpbkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbk 1 }
els10-27lpbkEntry OBJECT-TYPE
SYNTAX LxlpbkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27lpbkIndex }
::= { els10-27lpbkTable 1 }
LxlpbkEntry ::= SEQUENCE {
els10-27lpbkIndex
INTEGER,
els10-27lpbkOperation
INTEGER,
els10-27lpbkDestAddr
OCTET STRING,
els10-27lpbkPktNum
INTEGER,
els10-27lpbkInterval
TimeTicks,
els10-27lpbkPktLength
INTEGER,
els10-27lpbkIncrements
INTEGER,
els10-27lpbkGoods
Counter,
els10-27lpbkErrorNoReceives
Counter,
els10-27lpbkErrorBadReceives
Counter,
els10-27lpbkErrorSize
INTEGER,
els10-27lpbkErrorSent
OCTET STRING,
els10-27lpbkErrorReceived
OCTET STRING,
els10-27lpbkErrorOffset
INTEGER
}
els10-27lpbkIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 1 }
els10-27lpbkOperation OBJECT-TYPE
SYNTAX INTEGER {
loopback-off(1),
loopback-local(2),
loopback-remote(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 2 }
els10-27lpbkDestAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 3 }
els10-27lpbkPktNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 4 }
els10-27lpbkInterval OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 5 }
els10-27lpbkPktLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 6 }
els10-27lpbkIncrements OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 7 }
els10-27lpbkGoods OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 8 }
els10-27lpbkErrorNoReceives OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 9 }
els10-27lpbkErrorBadReceives OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 10 }
els10-27lpbkErrorSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 11 }
els10-27lpbkErrorSent OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 12 }
els10-27lpbkErrorReceived OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 13 }
els10-27lpbkErrorOffset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { els10-27lpbkEntry 14 }
-- Protocols Group
els10-27protoTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxprotoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains configuration information specify-
ing the types of protocols used to bridge, route,
translate, and filter frames for each port."
::= { els10-27proto 1 }
els10-27protoEntry OBJECT-TYPE
SYNTAX LxprotoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table specifies which protocols are
used by a particular port in the ES/1."
INDEX { els10-27protoIfIndex }
::= { els10-27protoTable 1 }
LxprotoEntry ::=
SEQUENCE {
els10-27protoIfIndex
INTEGER,
els10-27protoBridge
INTEGER,
els10-27protoSuppressBpdu
INTEGER,
els10-27protoRipListen
INTEGER,
els10-27protoTrunking
INTEGER,
els10-27sprotoTransmitPacing
INTEGER
}
els10-27protoIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies the interface (port) to which this entry's
information belongs. The value of this variable
corresponds to ifIndex, as well as most of the other
port identification values in related MIBs."
::= { els10-27protoEntry 1 }
els10-27protoBridge OBJECT-TYPE
SYNTAX INTEGER { transparent(1), none(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the bridging method to be applied to frames
received at, or destined for, this port. Ethernet and
FDDI ports may be configured for transparent, srt, or
none. Token Ring ports may be configured for any of
the four options. The UART may only be configured to
none."
::= { els10-27protoEntry 2 }
els10-27protoSuppressBpdu OBJECT-TYPE
SYNTAX INTEGER { normal(1), suppressed(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows transmission of spanning tree protocol packets
to be suppressed. If normal(1), 802.1d spanning tree
packets are
transmitted as usual. If suppressed(2), these packets
are not transmitted. This option may be needed for in-
teroperability with non-802.1d spanning tree protocols
(e.g., DEC LanBridge 100)."
::= { els10-27protoEntry 3 }
els10-27protoRipListen OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the port should listen for internet
Routing Information Protocol (RFC-1058) packets, in order to
build the routing table for the unit."
::= { els10-27protoEntry 4 }
els10-27protoTrunking OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether SMC's trunking protocol (an extension
to the standard Spanning Tree) is to be used over this port."
::= { els10-27protoEntry 5 }
els10-27sprotoTransmitPacing OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, introduces delays into normal transmission of frames, to
reduce the probability of collisions during heavy traffic."
::= { els10-27protoEntry 6 }
-- Trunking Group
els10-27trunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxtrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes the trunking status and attributes of
the interfaces that are configured for bridge trunking."
::= { els10-27trunk 1 }
els10-27trunkEntry OBJECT-TYPE
SYNTAX LxtrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry exists in this table for each physical interface
(port) that is configured for trunking."
INDEX { els10-27trunkIfIndex }
::= { els10-27trunkTable 1 }
LxtrunkEntry ::=
SEQUENCE {
els10-27trunkIfIndex
INTEGER,
els10-27trunkState
INTEGER,
els10-27trunkRemoteBridgeAddr
OCTET STRING,
els10-27trunkRemoteIp
IpAddress,
els10-27trunkLastError
INTEGER,
els10-27trunkLinkOrdinal
INTEGER,
els10-27trunkLinkCount
INTEGER,
els10-27trunkLastChange
INTEGER
}
els10-27trunkIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies a physical interface (port) which is
configured for LAN trunking. The value of this variable
corresponds to ifIndex, as well as most of the other
port identification values in related MIBs."
::= { els10-27trunkEntry 1 }
els10-27trunkState OBJECT-TYPE
SYNTAX INTEGER { off(1),
closed(2),
oneway(3),
joined(4),
perturbed(5),
helddown(6),
broken(7) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If off(1) then this link has not been enabled for trunking.
If closed(2) then this link has not yet received any Trunking
PDUs. If oneway(3) then incoming Trunking PDUs do not indicate
that our PDUs are being successfully received by the far end.
If joined(4) then this link is actively participating in the
trunk group. If perturbed(5) then this link is actively
participating in the trunk group; however, the transmission of
data packets has been temporarily stopped due to a change in
membership of the group. If helddown(6) then an error has been
detected and the link is being held out-of-service until the error
clears. If broken(7) then this link has been configured for trunking,
but the port is physically non-operational."
::= { els10-27trunkEntry 2 }
els10-27trunkRemoteBridgeAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address portion of the bridge ID of the remote bridge."
::= { els10-27trunkEntry 3 }
els10-27trunkRemoteIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the remote bridge, as reported by that
bridge for administrative purposes."
::= { els10-27trunkEntry 4 }
els10-27trunkLastError OBJECT-TYPE
SYNTAX INTEGER { none(1),
in-bpdu(2),
multiple-bridges(3),
ack-lost(4),
standby(5),
too-many-groups(6),
no-ack(7),
perturbed-threshold(8),
self-connect(9),
port-moved(10),
multiple-lan-types(11) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last reason for failure when the link is in closed, oneway, or helddown state."
::= { els10-27trunkEntry 5 }
els10-27trunkLinkOrdinal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The position of this link within the trunk group."
::= { els10-27trunkEntry 6 }
els10-27trunkLinkCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of links within the trunk group."
::= { els10-27trunkEntry 7 }
els10-27trunkLastChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds since els10-27trunkState changed."
::= { els10-27trunkEntry 8 }
-- Workgroup Group
els10-27WorkGroupNextNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The next available workgroup number to be used. When creating
a new workgroup, it is recommended to read the value of the variable
and use it to key into the workgroup table."
::= { els10-27workgroup 1 }
els10-27WorkGroupCurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of workgroups currently defined."
::= { els10-27workgroup 2 }
els10-27WorkGroupMaxCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of workgroups allowed."
::= { els10-27workgroup 3 }
els10-27WorkGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxWorkGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains work group definitions for the interfaces."
::= { els10-27workgroup 4 }
els10-27WorkGroupEntry OBJECT-TYPE
SYNTAX LxWorkGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table contains a definition of a work group."
INDEX { els10-27WorkGroupNumber }
::= { els10-27WorkGroupTable 1 }
LxWorkGroupEntry ::=
SEQUENCE {
els10-27WorkGroupNumber
INTEGER,
els10-27WorkGroupName
DisplayString,
els10-27WorkGroupPorts
OCTET STRING,
els10-27WorkGroupType
INTEGER
}
els10-27WorkGroupNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An integer that identifies the work group, used as an index
to this table."
::= { els10-27WorkGroupEntry 1 }
els10-27WorkGroupName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 1-16 character work group name."
::= { els10-27WorkGroupEntry 2 }
els10-27WorkGroupPorts OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of all ports within the group. The first
octet specified ports 1-8, the second 9-16, etc."
::= { els10-27WorkGroupEntry 3 }
els10-27WorkGroupType OBJECT-TYPE
SYNTAX INTEGER { all(3), -- all broadcast packets
invalid(4) } -- to delete this group
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of work group:
all - no additional information needs to be supplied."
::= { els10-27WorkGroupEntry 4 }
-- Trap Group
els10-27trapControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxtrapControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information about the severity of each trap
and whether the trap is currently enabled."
::= { els10-27trapMgt 1 }
els10-27trapControlEntry OBJECT-TYPE
SYNTAX LxtrapControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27trapIndex }
::= { els10-27trapControlTable 1 }
LxtrapControlEntry ::=
SEQUENCE {
els10-27trapIndex
INTEGER,
els10-27trapEnabled
INTEGER,
els10-27trapSeverity
INTEGER,
els10-27trapText
DisplayString
}
els10-27trapIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The specific trap number."
::= { els10-27trapControlEntry 1 }
els10-27trapEnabled OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable the generation of this trap."
::= { els10-27trapControlEntry 2 }
els10-27trapSeverity OBJECT-TYPE
SYNTAX INTEGER { informational(1),
warning(2),
minor(3),
major(4),
critical(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-definable severity, indicating the importance of the
trap."
::= { els10-27trapControlEntry 3 }
els10-27trapText OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the trap."
::= { els10-27trapControlEntry 4 }
els10-27trapSeverityControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxtrapSeverityControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information about whether a class of
traps of a particular severity are enabled or disabled."
::= { els10-27trapMgt 2 }
els10-27trapSeverityControlEntry OBJECT-TYPE
SYNTAX LxtrapSeverityControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27trapSeverity }
::= { els10-27trapSeverityControlTable 1 }
LxtrapSeverityControlEntry ::=
SEQUENCE {
els10-27trapSeverityControlSeverity
INTEGER,
els10-27trapSeverityEnable
INTEGER
}
els10-27trapSeverityControlSeverity OBJECT-TYPE
SYNTAX INTEGER { informational(1),
warning(2),
minor(3),
major(4),
critical(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-definable severity, indicating the importance of the
trap."
::= { els10-27trapSeverityControlEntry 1 }
els10-27trapSeverityEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable all traps of a given severity level."
::= { els10-27trapSeverityControlEntry 2 }
els10-27trapIncludeText OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Whether or not a formatted text string is included in the trap
PDU."
::= { els10-27trapMgt 3 }
els10-27trapTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time, in centiseconds, which should expire between the sending
of traps."
-- DEFVAL { 100 }
::= { els10-27trapMgt 4 }
els10-27trapRetry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of times any enterprise-specific trap is to be sent for
a given event. PDUs are retried using a truncated exponential backoff:
2 seconds, 4 seoncs, 8 seconds, 16 seconds, and then 32 seconds for
all succeeding intervals."
-- DEFVAL { 1 }
::= { els10-27trapMgt 5 }
els10-27trapNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of traps that are in the els10-27trapTable."
::= { els10-27trapMgt 6 }
els10-27trapTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxtrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the latest traps that have been generated."
::= { els10-27trapMgt 7 }
els10-27trapEntry OBJECT-TYPE
SYNTAX LxtrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { els10-27trapEntryIndex }
::= { els10-27trapTable 1 }
LxtrapEntry ::=
SEQUENCE {
els10-27trapEntryIndex
INTEGER,
els10-27trapEntryTimeStamp
TimeTicks,
els10-27trapEntryText
DisplayString,
els10-27trapEntryNumber
INTEGER,
els10-27trapEntrySeverity
INTEGER
}
els10-27trapEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A number representing the order in which the trap occurred
in time. This 32 bit number can wrap."
::= { els10-27trapEntry 1 }
els10-27trapEntryTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time at which the trap occurred."
::= { els10-27trapEntry 2 }
els10-27trapEntryText OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the trap."
::= { els10-27trapEntry 3 }
els10-27trapEntryNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The specific trap number, as specified in the TRAP PDU."
::= { els10-27trapEntry 4 }
els10-27trapEntrySeverity OBJECT-TYPE
SYNTAX INTEGER { informational(1),
warning(2),
minor(3),
major(4),
critical(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A user-definable severity, indicating the importance of the
trap."
::= { els10-27trapEntry 5 }
-- Ping Management MIB
els10-27pingDataTimeout OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time, in centiseconds, from the last ping activity (a send
or receive of an ECHO_RESPONSE or ECHO_REQUEST
message), to when the els10-27pingEntry information for that ping
request will be deleted."
::= {els10-27pingMgt 1}
els10-27pingTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxpingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The set of information describing the active ping requests and
their results."
::= {els10-27pingMgt 2}
els10-27pingEntry OBJECT-TYPE
SYNTAX LxpingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The parameters, state, and results of a ping request."
INDEX { els10-27pingNMSAddr,els10-27pingDestAddr }
::= {els10-27pingTable 1}
LxpingEntry ::= SEQUENCE {
els10-27pingNMSAddr
IpAddress,
els10-27pingDestAddr
IpAddress,
els10-27pingState
INTEGER,
els10-27pingCount
INTEGER,
els10-27pingDataSize
INTEGER,
els10-27pingWait
TimeTicks,
els10-27pingTimeOut
TimeTicks,
els10-27pingOperation
INTEGER,
els10-27pingMin
TimeTicks,
els10-27pingMax
TimeTicks,
els10-27pingAvg
TimeTicks,
els10-27pingNumTransmitted
INTEGER,
els10-27pingNumReceived
INTEGER
}
els10-27pingNMSAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the NMS, used to determine which ping
request to return information on."
::= {els10-27pingEntry 1}
els10-27pingDestAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address which is to be the destination of the ping
ECHO_REQUEST. This variable cannot be set while
els10-27pingOperation is on."
::= {els10-27pingEntry 2}
els10-27pingState OBJECT-TYPE
SYNTAX INTEGER {
not-started(0),
active (1),
timed-out (2),
completed (3)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the ping request. "
::= {els10-27pingEntry 3}
els10-27pingCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of ping requests which are to be sent. This
variable cannot be set while els10-27pingOperation is on."
::= { els10-27pingEntry 4}
els10-27pingDataSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The datagram packet size which will be sent with the
ECHO_REQUEST, in bytes. This variable cannot be set while
els10-27pingOperation is on."
::= { els10-27pingEntry 5}
els10-27pingWait OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time, in centiseconds, between the sending of each
ECHO_REQUEST message. This variable cannot be set while
els10-27pingOperation is on."
::= { els10-27pingEntry 6}
els10-27pingTimeOut OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time, in centiseconds, since the last ECHO_RESPONSE
was received (or the last ECHO_REQUEST was sent, if there
have been no responses) when the ping request will time out.
This variable cannot be set while els10-27pingOperation is on."
::= {els10-27pingEntry 7}
els10-27pingOperation OBJECT-TYPE
SYNTAX INTEGER {on (1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting els10-27pingOperation to on will begin the ping request.
Setting els10-27pingOperation to off will terminate the ping request."
::= {els10-27pingEntry 8}
els10-27pingMin OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum round trip time for the ping requests and
responses, in centiseconds."
::= {els10-27pingEntry 9}
els10-27pingMax OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum round trip for the ping requests and
responses, in centiseconds."
::= {els10-27pingEntry 10}
els10-27pingAvg OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The average round trip time for the ping requests and
responses, in centiseconds."
::= {els10-27pingEntry 11}
els10-27pingNumTransmitted OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ICMP ECHO_REQUEST messages that have
been transmitted during this ping request."
::= {els10-27pingEntry 12}
els10-27pingNumReceived OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ICMP ECHO_RESPONSE messages that have
been received as a result of this ping request."
::= {els10-27pingEntry 13}
-- Traceroute Management
els10-27traceDataTimeout OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time, in centiseconds, from the last traceroute activity (the
response to or timeout of the last probe sent), to when the
els10-27traceEntry information for that traceroute request will be
deleted."
::= {els10-27traceMgt 1}
els10-27traceTable OBJECT-TYPE
SYNTAX SEQUENCE OF LxtraceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The set of information describing the active traceroute requests
and their results."
::= {els10-27traceMgt 2}
els10-27traceEntry OBJECT-TYPE
SYNTAX LxtraceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The parameters, state, and results of a traceroute request."
INDEX { els10-27traceNMSAddr, els10-27traceDestAddr, els10-27traceHop,
els10-27traceProbe}
::= {els10-27traceTable 1}
LxtraceEntry ::= SEQUENCE {
els10-27traceNMSAddr
IpAddress,
els10-27traceDestAddr
IpAddress,
els10-27traceMaxTTL
INTEGER,
els10-27traceDataSize
INTEGER,
els10-27traceNumProbes
INTEGER,
els10-27traceWait
TimeTicks,
els10-27traceOperation
INTEGER,
els10-27traceHop
INTEGER,
els10-27traceHopAddr
IpAddress,
els10-27traceProbe
INTEGER,
els10-27traceState
INTEGER,
els10-27traceTime
TimeTicks
}
els10-27traceNMSAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the NMS, used to determine which traceroute
request to return information on."
::= {els10-27traceEntry 1}
els10-27traceDestAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address which is to be the destination of the traceroute
request.This variable cannot be set while els10-27traceOperation is on."
::= {els10-27traceEntry 2}
els10-27traceMaxTTL OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum time-to-live for outgoing traceroute probe
packets. This determines the number of hops that can be in a
traceroute. This variable cannot be set while els10-27traceOperation
is on."
::= {els10-27traceEntry 3}
els10-27traceDataSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The size of the datagram sent with each probe. This variable
cannot be set while els10-27traceOperation is on."
::= {els10-27traceEntry 4}
els10-27traceNumProbes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of probes which are sent for each hop. This
variable cannot be set while els10-27traceOperation is on."
::= {els10-27traceEntry 5}
els10-27traceWait OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time to wait in response to a probe. This variable cannot be
set while els10-27traceOperation is on."
::= {els10-27traceEntry 6}
els10-27traceOperation OBJECT-TYPE
SYNTAX INTEGER {on (1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting els10-27traceOperation to on will begin the traceroute request.
Setting els10-27traceOperation to off will terminate the traceroute
request."
::= {els10-27traceEntry 7}
els10-27traceHop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The hop count for a set of probes with a particular TTL."
::= {els10-27traceEntry 8}
els10-27traceHopAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the host which responded for a probe with a
particular TTL."
::= {els10-27traceEntry 9}
els10-27traceProbe OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The probe instance for a particular hop."
::= {els10-27traceEntry 10}
els10-27traceState OBJECT-TYPE
SYNTAX INTEGER {
not-started(0),
active (1),
time-exceeded(2),
host-unreachable (3),
net-unreachable (4),
completed (5)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the trace probe."
::= {els10-27traceEntry 11}
els10-27traceTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Round trip time of a probe for a particular hop."
::= {els10-27traceEntry 12}
-- Enterprise Specific Objects for Port Mirroring
els10-27volmirrorMode OBJECT-TYPE
SYNTAX INTEGER { off(0),
on(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
" To turn port mirroring on or off."
::= { els10-27volmirrorgroup 1 }
els10-27volmirrorPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The number of the port whose data will be mirrored to a
special monitor or analyzer port."
::= { els10-27volmirrorgroup 2 }
els10-27volmonitorPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Identifies the monitor or analyzer port to receive
frames from the special mirror port."
::= { els10-27volmirrorgroup 3 }
els10-27volMirrorMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27volMirrorMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" A table that contains information for the mirroring
on MAC addresses."
::= { els10-27volmirrorgroup 4 }
els10-27volmirrorMacEntry OBJECT-TYPE
SYNTAX Els10-27volMirrorMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Information about specific unicast MAC addresses
for which mirroring will act upon."
INDEX {els10-27volmirrorIndex}
::= { els10-27volMirrorMacTable 1 }
Els10-27volMirrorMacEntry ::= SEQUENCE {
els10-27volmirrorIndex
INTEGER,
els10-27volmirrorMac1
OCTET STRING
-- els10-27volmirrorMac2
-- OCTET STRING,
-- els10-27volmirrorMac3
-- OCTET STRING,
-- els10-27volmirrorMac4
-- OCTET STRING
}
els10-27volmirrorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Entry Index"
::= {els10-27volmirrorMacEntry 1}
els10-27volmirrorMac1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
" First MAC address for mirroring."
::= {els10-27volmirrorMacEntry 2}
--els10-27volmirrorMac2 OBJECT-TYPE
-- SYNTAX OCTET STRING
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Second MAC address for mirroring."
-- ::= {els10-27volMirrorMacEntry 2}
--els10-27volmirrorMac3 OBJECT-TYPE
-- SYNTAX OCTET STRING
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Third MAC address for mirroring."
-- ::= {els10-27volMirrorMacEntry 3}
--els10-27volmirrorMac4 OBJECT-TYPE
-- SYNTAX OCTET STRING
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Fourth MAC address for mirroring."
-- ::= {els10-27volMirrorMacEntry 4}
-- The els10-27VlanBridgeConfig group manages the overall configuration
-- of the bridge's VLAN resources.
--
-- The implementation of this group is MANDATORY.
els10-27VlanVersionNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the version IEEE 802.1Q VLAN that has been implemented to."
::= { els10-27VlanBridgeConfig 1 }
els10-27VlanOperatingMode OBJECT-TYPE
SYNTAX INTEGER { ieee8021d(1), ieee8021Q(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects the mode of operation. The switch can operate as simply an 802.1d switch,
or an 802.1d switch with IEEE VLAN capability (802.1Q). A read of this object will return
the current operating mode."
DEFVAL { ieee8021d }
::= { els10-27VlanBridgeConfig 2 }
els10-27VlanResetDefaults OBJECT-TYPE
SYNTAX INTEGER {
operating(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To reset the specified bridge. The filtering database is cleared and initialized
with the entries specified in the Permananent database, and the Bridge protocol Entity is
initialized. While initializing a read will return a value of reset (2). While
operational a read will return a value of operating (2)."
::= { els10-27VlanBridgeConfig 3 }
els10-27VlanGVRPEnable OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the switch is operating in 802.1Q mode, this selects whether GVRP protocol
messages should be processed and VLANs configured accordingly for each
port on the switch. Each octet within the value of this object specifies a set of eight
ports, with the first octet specifying ports 1 through 8, the next octet specifying ports
9 through 16, etc. Within each octet, the least significant bit represents the
lowest numbered port, and the most significant bit represents the highest numbered port.
Thus, each port of the VLAN bridge is represented by single bit
within the value of this object. If that bit has a value of '1' then that port is
included in the set of ports; the port is not included if its bit has a value of '0'"
DEFVAL { disabled }
::= { els10-27VlanBridgeConfig 4 }
els10-27VlanAccessList OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of ports that should act as 'Access Ports'. These ports will strip all tags
on egress and also make use of a shared database that will automatically be kept by the
firmware. Each octet within the value of this object specifies a set of eight ports, with
the first octet specifying ports 1 through 8, the next octet specifying ports 9 through
16, etc. Within each octet, the least significant bit represents the lowest numbered
port, and the most significant bit represents the highest numbered port. Thus, each port
of the VLAN bridge is represented by single bit within the value of this object. If that
bit has a value of '1' then that port is included in the set of ports; the port is not
included if its bit has a value of '0'"
::= { els10-27VlanBridgeConfig 5 }
els10-27VlanConfigVlan OBJECT IDENTIFIER ::= { els10-27VlanBridgeConfig 6 }
-- The els10-27VlanConfigVlan manages the configuration of a specific
-- VLAN within a bridge.
-- Each VLAN will have an entry in the els10-27VlanConfigTable
--
-- The implementation of this group is MANDATORY.
els10-27VlanNumActiveEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active VLAN entries for the device. This includes both static and
dynamic VLANs."
::= { els10-27VlanConfigVlan 1 }
els10-27VlanNumConfiguredEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of configured VLAN entries for the device."
::= { els10-27VlanConfigVlan 2 }
els10-27VlanMaxNumEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of VLAN entries for the device."
::= { els10-27VlanConfigVlan 3 }
els10-27VlanConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27VlanConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table allows for the creation, deletion, and modification of
specific VLANs. The ports defined within this group will be members of the 'member
set' as
defined in the IEEE 802.1Q specification."
::= { els10-27VlanConfigVlan 4 }
els10-27VlanConfigEntry OBJECT-TYPE
SYNTAX Els10-27VlanConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for configuration of specific VLAN entries."
INDEX { els10-27VlanConfigVID }
::= { els10-27VlanConfigTable 1 }
Els10-27VlanConfigEntry ::= SEQUENCE {
els10-27VlanConfigIndex
INTEGER,
els10-27VlanConfigVID
INTEGER,
els10-27VlanConfigPorts
INTEGER,
els10-27VlanConfigIP
INTEGER,
els10-27VlanConfigIPMask
INTEGER,
els10-27VlanConfigName
DisplayString,
els10-27VlanConfigStatus
INTEGER,
els10-27VlanConfigEstablish
INTEGER
}
els10-27VlanConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interface being configured."
::= { els10-27VlanConfigEntry 1 }
els10-27VlanConfigVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The 12 bit VLAN Identifier associated with the configured VLAN."
::= { els10-27VlanConfigEntry 2 }
els10-27VlanConfigPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Each octet within the value of this object specifies
a set of eight ports, with the first octet specifying
ports 1 through 8, the next octet specifying ports 9
through 16, etc. Within each octet, the least significant
bit represents the lowest numbered port, and the most
significant bit represents the highest numbered port.
Thus, each port of the VLAN bridge is represented by
single bit within the value of this object. If that bit
has a value of '1' then that port is included in the set
of ports; the port is not included if its bit has a value of '0'."
::= { els10-27VlanConfigEntry 3 }
els10-27VlanConfigIP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address to be used to access the unit on this Vlan. This must be a
valid host address."
::= { els10-27VlanConfigEntry 4 }
els10-27VlanConfigIPMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP subnet mask to be used with this Ip address."
::= { els10-27VlanConfigEntry 5 }
els10-27VlanConfigName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ASCII name associated with the configured VLAN.
A set of this object prior to creating an entry by
setting els10-27VlanEstablish will fail with a NO-INSTANCE error."
::= { els10-27VlanConfigEntry 6 }
els10-27VlanConfigStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set with the value of enable(1), enables all associated entries
in els10-27VlanConfigVID table for the specified VLAN. A set of
disable(2), disables all els10-27VlanConfigVID entries associated with
the specified VLAN. A set of this object prior to creating an entry by
setting els10-27VlanConfigEstablish will fail with a NO-INSTANCE error."
DEFVAL { disable }
::= { els10-27VlanConfigEntry 7 }
els10-27VlanConfigEstablish OBJECT-TYPE
SYNTAX INTEGER {
create(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set of the value create(1), causes an entry to be created in
the els10-27VlanConfigTable as specified by the instancing information
of els10-27VlanConfigVID, els10-27VlanConfigName, and els10-27VlanConfigPorts.
A set of delete(2) causes the specified entry to be removed from the table.
A read of this object will always return create(1)."
::= { els10-27VlanConfigEntry 8 }
els10-27VlanConfigEgressTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27VlanConfigEgressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table allows for the specifying of the default VLAN ID for a specific port. If
NOT configured as an 'Access' port, then packets containing this VLAN ID will have the tag
stripped on egress. This will set the PVID for each port contained within the list."
::= { els10-27VlanConfigVlan 5 }
els10-27VlanConfigEgressEntry OBJECT-TYPE
SYNTAX Els10-27VlanConfigEgressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for configuration of specific VLAN entries."
INDEX { els10-27VlanEgressVID }
::= { els10-27VlanConfigEgressTable 1 }
Els10-27VlanConfigEgressEntry ::= SEQUENCE {
els10-27VlanEgressIndex
INTEGER,
els10-27VlanEgressVID
INTEGER,
els10-27VlanEgressList
INTEGER,
els10-27VlanEgressStatus
INTEGER
}
els10-27VlanEgressIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The index into the Vlan table. A port must be a member of this Vlan prior
to assigning this Id as the default. "
::= { els10-27VlanConfigEgressEntry 1 }
els10-27VlanEgressVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The 12 bit VLAN Identifier associated with the configured VLAN."
::= { els10-27VlanConfigEgressEntry 2 }
els10-27VlanEgressList OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set of ports to which traffic destined for
the VLAN specified by els10-27VlanEgressVID
on the device will have this tag stripped on
egress. Each octet within the value of
this object specifies a set of eight ports, with thee
first octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc. Within each
octet, the least significant bit represents the lowest
numbered port, and the most significant bit represents
the highest numbered port. Thus, each port of the VLAN
bridge is represented by a single bit within the value
of this object. If that bit has a value of '1' then
that port is included in the set of ports; the port is
not included if its bit has a value of '0'."
::= { els10-27VlanConfigEgressEntry 3 }
els10-27VlanEgressStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set with the value of enable(1), enables all associated entries
in els10-27VlanEgressVID table for the specified VLAN. A set of
disable(2), disables all els10-27VlanEgressVID entries associated with
the specified VLAN. A set of this object prior to creating an entry by
setting els10-27VlanEgressEstablish will fail with a NO-INSTANCE error."
DEFVAL { disable }
::= { els10-27VlanConfigEgressEntry 4 }
els10-27VlanFilterGVRPTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27VlanFilterGVRPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table allows for the specifying of VLAN ID's that will be resticted from being learnt
by the device. If a GVRP packet is received specifying this VLAN ID, it will be ignored."
::= { els10-27VlanConfigVlan 6 }
els10-27VlanFilterGVRPEntry OBJECT-TYPE
SYNTAX Els10-27VlanFilterGVRPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for configuration of specific entries."
INDEX { els10-27VlanFilterGVRPVID }
::= { els10-27VlanFilterGVRPTable 1 }
Els10-27VlanFilterGVRPEntry ::= SEQUENCE {
els10-27VlanFilterGVRPIndex
INTEGER,
els10-27VlanFilterGVRPVID
INTEGER,
els10-27VlanFilterGVRPList
INTEGER,
els10-27VlanFilterGVRPStatus
INTEGER,
els10-27VlanFilterGVRPEstablishVID
INTEGER
}
els10-27VlanFilterGVRPIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The index into the Vlan Filter table. A maximum of 32
Vlan ID can be restricted from being learnt via GVRP. "
::= { els10-27VlanFilterGVRPEntry 1 }
els10-27VlanFilterGVRPVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The 12 bit VLAN Identifier associated with the configured VLAN."
::= { els10-27VlanFilterGVRPEntry 2 }
els10-27VlanFilterGVRPList OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set of ports that will be restricted from leaning
of a VLAN ID from a GVRP message. The VLAN ID
is specified by els10-27VlanFilterGVRPVID.
Each octet within the value of
this object specifies a set of eight ports, with thee
first octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc. Within each
octet, the least significant bit represents the lowest
numbered port, and the most significant bit represents
the highest numbered port. Thus, each port of the VLAN
bridge is represented by a single bit within the value
of this object. If that bit has a value of '1' then
that port is included in the set of ports; the port is
not included if its bit has a value of '0'."
::= { els10-27VlanFilterGVRPEntry 3 }
els10-27VlanFilterGVRPStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set with the value of enable(1), enables all associated entries
in els10-27VlanFilterGVRPVID table for the specified VLAN. A set of
disable(2), disables all els10-27VlanFilterGVRPVID entries associated with
the specified VLAN. A set of this object prior to creating an entry by
setting els10-27VlanConfigEstablish will fail with a NO-INSTANCE error."
DEFVAL { disable }
::= { els10-27VlanFilterGVRPEntry 4 }
els10-27VlanFilterGVRPEstablishVID OBJECT-TYPE
SYNTAX INTEGER {
create(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set of the value create(1), causes an entry to be created in
the els10-27VlanFilterGVRPTable as specified by the instancing information
of els10-27VlanFilterGVRpVID, and els10-27VlanFilterGVRPPorts.
A set of delete(2) causes the specified entry to be removed from the table.
A read of this object will always return create(1)."
::= { els10-27VlanFilterGVRPEntry 5 }
els10-27VlanStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27VlanStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for configuration of specific VLAN/MAC Address entries and to specify the
port to which traffic destined for this address pair should be forwarded. These entries
will not be aged out of the forwarding data base."
::= { els10-27VlanConfigVlan 7 }
els10-27VlanStaticEntry OBJECT-TYPE
SYNTAX Els10-27VlanStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Allows for specifying specific entries."
INDEX { els10-27VlanStaticVID }
::= { els10-27VlanStaticTable 1 }
Els10-27VlanStaticEntry ::= SEQUENCE {
els10-27VlanStaticVID
INTEGER,
els10-27VlanStaticMAC
PhysAddress,
els10-27VlanStaticPort
INTEGER,
els10-27VlanStaticEstablish
INTEGER
}
els10-27VlanStaticVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The 12 bit VLAN Identifier associated with the configured VLAN."
::= { els10-27VlanStaticEntry 1 }
els10-27VlanStaticMAC OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The media dependent physical address."
::= { els10-27VlanStaticEntry 2 }
els10-27VlanStaticPort OBJECT-TYPE
SYNTAX INTEGER (1.. 27)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An integer designating the port number to associate this address to."
::= { els10-27VlanStaticEntry 3 }
els10-27VlanStaticEstablish OBJECT-TYPE
SYNTAX INTEGER {
create(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set of the value create(1), causes an entry to be created as specified by the instancing
information of els10-27VlanSaticVID, els10-27VlanStaticMAC, and els10-27VlanStaticPorts. A set of
delete(2) causes the specified entry to be removed from thetable.
A read of this object will always return create(1)."
::= { els10-27VlanStaticEntry 4 }
-- the IP Multicast group
els10-27IPMulticastStatus OBJECT-TYPE
SYNTAX INTEGER {enabled (1),
disabled (0)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Parameter to enable or disable IP multicast filtering
on the device. When enabled, the device will examine IP
Multicast data packets and dynamically set up filter
ports to prevent flooding.
The default is disabled."
::= {els10-27volipmgroup 1}
els10-27ipmInterfaceRtr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parameter to enable or disable the inclusion of this
interface in all Multicast filters. When enabled, all
IP Multicast packets for all group filters will be
transmitted over this interface. Value is a bit mask."
::= {els10-27volipmgroup 2}
-- the IGMP group
els10-27igmpStatus OBJECT-TYPE
SYNTAX INTEGER {enabled (0),
disabled (1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parameter to enable or disable IGMP snooping on
the device. When enabled, the device will examine IGMP
packets and set up filters for IGMP ports.
The default is enabled."
::= {els10-27voligmpgroup 1}
els10-27igmpQueryStatus OBJECT-TYPE
SYNTAX INTEGER {enabled (1),
disabled (0) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parameter to enable or disable the device to act as a
Querier. If enabled, the device will send out a Query
as a Proxy to solicit reports. The device will not
become an IGMP router.
The default is disabled."
::= {els10-27voligmpgroup 2}
els10-27igmpQueryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum number of queries that have not been heard on the
system before the system starts taking action to solicit
reports (default is 5)."
::= {els10-27voligmpgroup 3}
els10-27igmpPortDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Timeout value (mins) between IGMP Reports or IGMP Queries
received on a port before the system times out the entry
from the Multicast Address Filter (default is 5 minutes)."
::= {els10-27voligmpgroup 4}
-- The IGMP Cache Table
els10-27igmpCacheTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27igmpCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table listing the IP multicast groups
for which there are members on a particular interface."
::={els10-27voligmpgroup 5}
els10-27igmpCacheEntry OBJECT-TYPE
SYNTAX Els10-27igmpCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the els10-27igmpCacheTable."
INDEX {els10-27igmpCacheAddress,els10-27igmpCacheIfIndex}
::={els10-27igmpCacheTable 1}
Els10-27igmpCacheEntry ::= SEQUENCE {
els10-27igmpCacheAddress
IpAddress,
els10-27igmpCacheIfIndex
INTEGER,
els10-27igmpCacheExpiryTime
TimeTicks
}
els10-27igmpCacheAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP multicast group address for which this entry
contains information."
::={els10-27igmpCacheEntry 1}
els10-27igmpCacheIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface for which this entry contains infor-
mation for an IP multicast group address."
::={els10-27igmpCacheEntry 2}
els10-27igmpCacheExpiryTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum amount of time remaining before this
entry will be aged out."
::={els10-27igmpCacheEntry 3}
-- The els10-27FlowControl MIB is used to manage Volcano devices.
-- This managed object will allow for control and statistics
-- on half duplex flow control (back pressure) ports and IEEE 802.3x full
-- duplex flow control ports.
els10-27FlowControlBackPressure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Control back pressure on a system wide basis.
On (1),
Off (2)"
::= { els10-27FlowControlCtl 1 }
els10-27FlowControlThresholdValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A value specified as a percent of the available buffers.
When fewer than the percent of the avaialable buffers
is detected, flow control will be initiated. Flow control
will cease when the free buffer count meets or exceeds
this percent."
::= { els10-27FlowControlCtl 2 }
els10-27FlowControlPauseInteval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value between 10 and 65535. Each pause interval is equal
to '5.12 microseconds'. A value of 10 will equal '51.2
microseconds'."
::= { els10-27FlowControlCtl 3 }
els10-27FlowControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Els10-27FlowControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Provides a list of control objects over flow control parameters."
::= { els10-27FlowControlCtl 4 }
els10-27FlowControlEntry OBJECT-TYPE
SYNTAX Els10-27FlowControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Defines a particular entry containing objects pertaining to
definition and control over flow control ports."
INDEX { els10-27FlowControlInterface}
::= { els10-27FlowControlTable 1 }
Els10-27FlowControlEntry ::= SEQUENCE {
els10-27FlowControlInterface
INTEGER,
els10-27FlowControlEnable
INTEGER,
els10-27FlowControlRxPauseFrames
INTEGER,
els10-27FlowControlTxPauseFrames
INTEGER
}
els10-27FlowControlInterface OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The MIB2 interface for which this flow control information pertains"
::= { els10-27FlowControlEntry 1 }
els10-27FlowControlEnable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Control 802.3x flow control on a per interface basis.
On (1),
Off (2)"
::= { els10-27FlowControlEntry 2 }
els10-27FlowControlRxPauseFrames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of pause frames received on this interface."
::= { els10-27FlowControlEntry 3 }
els10-27FlowControlTxPauseFrames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of pause frames transmitted on this interface."
::= { els10-27FlowControlEntry 4 }
-- Enterprise Specific Traps for the ELS10-27
els10-27WriteStatusTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27swdisWriteStatus,
els10-27swdisDesc
}
DESCRIPTION
"Sent when a bank of Flash EPROM has been erased. If
els10-27swdisWriteStatus indicates success, then the unit is ready
to be downloaded with the new software."
::= 2
els10-27PortFunctionsTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27ifFunction
}
DESCRIPTION
"Sent whenever the current functional state (active
protocols) of the port has changed."
::= 3
els10-27RxQueuesTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27ifRxQueues
}
DESCRIPTION
"Sent whenever the number of times that the port's receiver
has stopped receiving packets due to buffer space shortages
has exceeded the port's limit."
::= 4
els10-27RxStormFlagTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity
}
DESCRIPTION
"Sent whenever broadcast/multicast storm protection has been invoked
for the port."
::= 5
els10-27TxCongestsTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27adminNAMReceiveCongests
}
DESCRIPTION
"Sent whenever packets destined for the unit itself were
discarded due to lack of buffer space."
::= 6
els10-27DebugStringIdTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27debugStringID,
els10-27debugString
}
DESCRIPTION
"Sent whenever the unit has a debug text string to be
displayed. The text strings are sent in a stream-like
fashion."
::= 8
els10-27LpbkOperationTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27lpbkOperation,
els10-27lpbkErrorNoReceives,
els10-27lpbkErrorBadReceives
}
DESCRIPTION
"Send whenever the unit has finished a loop back test, or
a loop back error has been detected."
::= 9
els10-27TrunkStateTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkState
}
DESCRIPTION
"A trunking state change transition has occurred. The possible
transitions are:
CLOSED-ONEWAY
ONEWAY-PERTURBED
PERTURBED-JOINED
JOINED-HELDDOWN
CLOSED-HELDDOWN
ONEWAY-HELDDOWN
PERTURBED-HELDDOWN"
::= 10
els10-27TrunkBridgeAddrTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkRemoteBridgeAddr
}
DESCRIPTION
"The associated trunking MAC address of the bridge ID of the remote
bridge has changed."
::= 11
els10-27TrunkIPAddrTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkRemoteIp
}
DESCRIPTION
"The associated trunking IP address of the remote bridge has changed."
::= 12
els10-27TrunkErrorTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkLastError
}
DESCRIPTION
"An error has occurred in trunking."
::= 13
els10-27TrunkLinkOrdinalTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkLinkOrdinal
}
DESCRIPTION
"The port's index in the trunking group has changed."
::= 14
els10-27TrunkLinkCountTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27trunkLinkCount
}
DESCRIPTION
"The number of ports in the trunking group has changed."
::= 15
els10-27DiagUnitBootedTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27adminFatalErr
}
DESCRIPTION
"The unit has booted. els10-27adminFatalErr contains information about
why the unit rebooted."
::= 16
els10-27StorageFailureTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity
}
DESCRIPTION
"Sent if the unit's Configuration EEPROM has failed. The unit
will not be able to reboot, and must be returned to the
factory."
::= 17
els10-27PortCongestedTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
ifOutDiscards
}
DESCRIPTION
"Sent whenever outbound congestion control has been invoked
for the port."
::= 18
els10-27TopChangeBegunTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity
}
DESCRIPTION
"The spanning tree topology has begun to change."
::= 19
els10-27TopChangeEndTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity
}
DESCRIPTION
"The spanning tree topology has stopped changing."
::= 20
els10-27IfErrorsTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
ifInErrors,
ifOutErrors
}
DESCRIPTION
"Sent whenever the number of hardware errors in received and
transmitted packets has exceeded the port's limit."
::= 21
els10-27StRootIDTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpDesignatedRoot
}
DESCRIPTION
"The spanning tree root bridge ID for the unit has changed."
::= 22
els10-27StRootCostTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpRootCost
}
DESCRIPTION
"The unit's spanning tree cost to the root bridge has changed."
::= 23
els10-27StRootPortTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpRootPort
}
DESCRIPTION
"The unit's spanning tree root port has changed."
::= 24
els10-27StMaxAgeTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpMaxAge
}
DESCRIPTION
"The unit's spanning tree maximum age has changed."
::= 25
els10-27StHelloTimeTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpHelloTime
}
DESCRIPTION
"The unit's spanning tree hello time has changed."
::= 26
els10-27StForwardDelayTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpForwardDelay
}
DESCRIPTION
"The unit's spanning tree forward delay time has changed."
::= 27
els10-27StDesigRootTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortDesignatedRoot
}
DESCRIPTION
"The Root Bridge ID in received Spanning Tree Configuration BPDUs
from the port has changed."
::= 28
els10-27StPortDesigBridgeTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortDesignatedBridge
}
DESCRIPTION
"The bridge ID of the spanning tree designated bridge of the LAN/WAN
to which the port is attached has changed."
::= 29
els10-27StPortDesigCostTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortDesignatedCost
}
DESCRIPTION
"The cost to the spanning tree root bridge from the designated port of
the LAN/WAN to which the port is attached has changed."
::= 30
els10-27StPortDesigPortTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortDesignatedPort
}
DESCRIPTION
"The port ID of the spanning tree designated port of the LAN/WAN
to which the port is attached has changed."
::= 31
els10-27StPortStateTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortState
}
DESCRIPTION
"The spanning tree state of the port has changed."
::= 32
els10-27hwDiagTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
els10-27hwDiagCode
}
DESCRIPTION
"Sent whenever the unit's diagnostics have indicated an error."
::= 100
els10-27InvalidConfigurationFileTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortDesignatedPort
}
DESCRIPTION
"Diagnostics has detected corrupted configuration data.
Default parameter values have been restored."
::= 34
els10-27StInvalidFlashCodeImageTrap TRAP-TYPE
ENTERPRISE sigma
VARIABLES {
els10-27trapSeverity,
dot1dStpPortState
}
DESCRIPTION
"An invalid code image was detected in flash memory.
An attempt will be made to obtain a valid image."
::= 35
END