mibs/MIBS/enterasys/CTRON-FRONTPANEL-MIB

183 lines
6.8 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CTRON-FRONTPANEL-MIB DEFINITIONS ::= BEGIN
-- ctron-frontpanel-mib.txt
-- Revision: 1.04.00
-- Part Number: 2170558-02
-- Date: August 11, 1995
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific front panel MIB.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright October 95 Cabletron Systems
-- This MIB describes objects that define front panel
-- redundance within the MMAC chassis.
IMPORTS
NetworkAddress FROM RFC1155-SMI
ctFpRedundancy FROM CTRON-MIB-NAMES
OBJECT-TYPE FROM RFC-1212;
-- The fPredund group
-- Implementation of this group is mandatory for devices with
-- front panel redundancy.
ctFpRedund OBJECT IDENTIFIER ::= { ctFpRedundancy 1 }
ctFpRedundReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to Reset it will cause a reset
of the front panel redundancy. Setting this object to
NoReset will do nothing. This object will always be
read as NoReset."
::= { ctFpRedund 1 }
ctFpRedundPollInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the number of seconds between polls for front
panel redundancy."
::= { ctFpRedund 2 }
ctFpRedundRetrys OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the the number of unanswered polls allowed for
the front panel redundancy before it switches ports."
::= { ctFpRedund 3 }
ctFpRedundNumAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the number of IP Addresses associated with front panel
redundancy."
::= { ctFpRedund 4 }
ctFpRedundAddAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an IP Address to the polling list for the front panel
redundancy."
::= { ctFpRedund 5 }
ctFpRedundDelAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete an IP Address from the polling list for the
front panel redundancy."
::= { ctFpRedund 6 }
ctFpRedundActivePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the front panel port you want to be active
when front panel redundancy is enabled."
::= { ctFpRedund 7 }
ctFpRedundEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to enable, the front panel
redundancy will be activated. If this object is set
to disable, the front panel redundancy will be
deactivated. When read, this object will returns the
state of the object based on the last request
made."
::= { ctFpRedund 8 }
ctFpRedundAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFpRedundAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ctFpRedund 9 }
ctFpRedundAddrEntry OBJECT-TYPE
SYNTAX CtFpRedundAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { ctFpRedundAddrId }
::= { ctFpRedundAddrTable 1 }
CtFpRedundAddrEntry ::=
SEQUENCE {
ctFpRedundAddrId
INTEGER,
ctFpRedundAddrIPAddr
NetworkAddress
}
ctFpRedundAddrId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value identifying an element in a sequence of
member IP Addresses which belong to the front panel
redundancy. This value goes from 1 to the maximum
number of IP Addresses which may be included in
front panel redundancy."
::= { ctFpRedundAddrEntry 1 }
ctFpRedundAddrIPAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns an IP Address associated with the front panel
redundancy."
::= { ctFpRedundAddrEntry 2 }
END