mibs/MIBS/enterasys/CTRON-SFCS-MIB

5554 lines
196 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CTRON-SFCS-MIB DEFINITIONS ::= BEGIN
-- ctron-sfcs-mib.txt
-- Revision: 1.00.01
-- Date: March 23, 1999
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for Cabletron's
-- enterprise specific Secure Fast Cell Switching MIB.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright October 98 Cabletron Systems
--
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
enterprises, IpAddress, TimeTicks
FROM RFC1155-SMI
TruthValue
FROM SNMPv2-TC
atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex,
atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci,
atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi,
atmVcCrossConnectHighVci
FROM ATM-MIB;
cabletron OBJECT IDENTIFIER ::= { enterprises 52 }
mibs OBJECT IDENTIFIER ::= { cabletron 4 }
ctron OBJECT IDENTIFIER ::= { mibs 1 }
ctDataLink OBJECT IDENTIFIER ::= { ctron 2 }
ctSwitch OBJECT IDENTIFIER ::= { ctDataLink 11 }
ctsfSwitch OBJECT IDENTIFIER ::= { ctSwitch 1 }
ctSFCS OBJECT IDENTIFIER ::= { ctsfSwitch 1 }
-- The SFCS Groups.
-- The SFCS System Groups (switch system)
sfcsSystem OBJECT IDENTIFIER ::= { ctSFCS 1 }
sfcsSysConfig OBJECT IDENTIFIER ::= { sfcsSystem 1 }
sfcsSysStatus OBJECT IDENTIFIER ::= { sfcsSystem 2 }
sfcsSysSystemCfg OBJECT IDENTIFIER ::= { sfcsSystem 3 }
sfcsSysBPCfg OBJECT IDENTIFIER ::= { sfcsSystem 4 }
-- All groups from here on represent a single switch module
-- The SFCS Engine Groups
sfcsEngine OBJECT IDENTIFIER ::= { ctSFCS 2 }
sfcsConfig OBJECT IDENTIFIER ::= { sfcsEngine 1 }
sfcsStatus OBJECT IDENTIFIER ::= { sfcsEngine 2 }
sfcsUPCEngine OBJECT IDENTIFIER ::= { sfcsEngine 3 }
sfcsStatisticsEngine OBJECT IDENTIFIER ::= { sfcsEngine 4 }
sfcsPacketDiscardEngine OBJECT IDENTIFIER ::= { sfcsEngine 5 }
-- The SFCS ANIM Groups
sfcsANIM OBJECT IDENTIFIER ::= { ctSFCS 3 }
sfcsANIMConfig OBJECT IDENTIFIER ::= { sfcsANIM 1 }
sfcsANIMStatistics OBJECT IDENTIFIER ::= { sfcsANIM 2 }
sfcsANIMPic OBJECT IDENTIFIER ::= { sfcsANIM 3 }
-- The SFCS Interface Groups
sfcsInterface OBJECT IDENTIFIER ::= { ctSFCS 4 }
sfcsInterfaceConfig OBJECT IDENTIFIER ::= { sfcsInterface 1 }
sfcsInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsInterface 2 }
-- The SFCS Queue Groups
sfcsQueue OBJECT IDENTIFIER ::= { ctSFCS 5 }
sfcsQueueConfig OBJECT IDENTIFIER ::= { sfcsQueue 1 }
sfcsQueueStatistics OBJECT IDENTIFIER ::= { sfcsQueue 2 }
-- The SFCS Connection Groups
sfcsConnection OBJECT IDENTIFIER ::= { ctSFCS 7 }
sfcsConnectionConfig OBJECT IDENTIFIER ::= { sfcsConnection 1 }
sfcsConnectionStatistics OBJECT IDENTIFIER ::= { sfcsConnection 2 }
sfcsConnectionError OBJECT IDENTIFIER ::= { sfcsConnection 3 }
-- The SFCS Connection API Group
sfcsConnectionAPI OBJECT IDENTIFIER ::= { ctSFCS 8 }
-- The SFCS CTM Groups
sfcsCTM OBJECT IDENTIFIER ::= { ctSFCS 9 }
sfcsCTMInterfaceConfig OBJECT IDENTIFIER ::= { sfcsCTM 1 }
sfcsCTMInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsCTM 2 }
sfcsCTMQueueConfig OBJECT IDENTIFIER ::= { sfcsCTM 3 }
sfcsCTMQueueStatistics OBJECT IDENTIFIER ::= { sfcsCTM 4 }
-- The SFCS Bandwidth Managment Groups
sfcsBWMgr OBJECT IDENTIFIER ::= { ctSFCS 12 }
sfcsBwNims OBJECT IDENTIFIER ::= { sfcsBWMgr 1 }
sfcsBwPorts OBJECT IDENTIFIER ::= { sfcsBWMgr 2 }
sfcsBwPortPools OBJECT IDENTIFIER ::= { sfcsBWMgr 3 }
sfcsBuffPools OBJECT IDENTIFIER ::= { sfcsBWMgr 4 }
-- The ANIM Proxy Groups
sfcsProxy OBJECT IDENTIFIER ::= { ctSFCS 13 }
sfcsProxyConfig OBJECT IDENTIFIER ::= { sfcsProxy 1 }
sfcsProxyTrans OBJECT IDENTIFIER ::= { sfcsProxy 2 }
sfcsProxyRead OBJECT IDENTIFIER ::= { sfcsProxy 3 }
sfcsSysConfigTable OBJECT IDENTIFIER ::= { sfcsSysConfig 1 }
sfcsSysConfigEnt OBJECT IDENTIFIER ::= { sfcsSysConfigTable 1 }
sfcsSysConfigAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- startup the SFCS
disabled(2), -- shutdown the SFCS
other(3) -- none of the following
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS switching
services for this virtual switch. This controls the
SFCS state at a chassis level. Regardless of the
per-interface state of each SFCS switching element
and the state of active connections, writing the value
disabled(2) will cause the entire switch to immediately
shutdown.
enabled(1) -- startup the SFCS
disabled(2) -- shutdown the SFCS
other(3) -- none of the following"
::= { sfcsSysConfigEnt 1 }
sfcsSysConfigOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- running
disabled(2), -- not running
other(3), -- none of the following
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of this switch.
enabled(1) -- running
disabled(2) -- not running
other(3) -- none of the following
pending-disable(4) -- shut-down in progress
pending-enable(5) -- start-up in progress
invalid-config(6) -- not running,invalid config"
::= { sfcsSysConfigEnt 2 }
sfcsSysConfigOperTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (# of time ticks) that
this switch system has been in its current operational
state."
::= { sfcsSysConfigEnt 3 }
sfcsSysConfigLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the last time a change was made to the
configuration entry for this switch."
::= { sfcsSysConfigEnt 4 }
sfcsSysConfigSwitchCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum front panel bandwidth based on current
hardware configuration of the switch in Mbps"
::= { sfcsSysConfigEnt 5 }
sfcsSysConfigMaxCnxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of connections which
can be established on this switch."
::= { sfcsSysConfigEnt 6 }
sfcsSysConfigMaxStatEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of stats enabled VCs for this
switch."
::= { sfcsSysConfigEnt 7 }
sfcsSysConfigMaxUpcEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of UPC enabled VCs for this
switch."
::= { sfcsSysConfigEnt 8 }
sfcsSysConfigNumberANIMS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of ATM Network Inteface Modules
currently configured on this switch."
::= { sfcsSysConfigEnt 9 }
sfcsSysConfigInterfaceCapability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total bandwidth capability(of the engine)
for this switch expressed in Mbps."
::= { sfcsSysConfigEnt 10 }
sfcsSysConfigTypeofSwitch OBJECT-TYPE
SYNTAX INTEGER {
other (1),
sfcellswitch (2),
sfpacketswitch (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates what type of switch this is.
other(1)
sfcellswitch(2)
sfpacketswitch(3)"
::= { sfcsSysConfigEnt 11 }
sfcsSysConfigPolicingSupport OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not this switch supports policing.
supported(1)
not supported(2)"
::= { sfcsSysConfigEnt 12 }
sfcsSysConfigPnniNsapPrefix OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(13))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the 13 byte NSAP prefix to use
with address registration."
::= { sfcsSysConfigEnt 13 }
sfcsSysConfigPnniNodeLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the PNNI node level value.
The range can be from 0 to 104."
::= { sfcsSysConfigEnt 14 }
sfcsSysConfigPnniAddessingMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the PNNI addressing mode - that
can range from 0 to 2.
0 - Auto Mode using MAC
1 - Auto Mode using board#
2 - Manual "
::= { sfcsSysConfigEnt 15 }
sfcsSysConfigPnniAddessingAdmnStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the PNNI addressing admn status.
Down - 2. Up - 1."
::= { sfcsSysConfigEnt 16 }
sfcsSysConfigFMVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the Firmware Revision of the switch."
::= { sfcsSysConfigEnt 17 }
sfcsSysConfigCTMSlotMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the slot mask for all ctm boards in the chassis.
The least significant bit represents slot 1."
::= { sfcsSysConfigEnt 18 }
sfcsSysConfigMaxfreecva OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the maximum number of CAC connection blocks that
CAC will allow on its free list. The default is 1024. If too low
CAC performance will degrade (thrashing control blocks), If too high,
memory exhaustion may occur.
"
::= { sfcsSysConfigEnt 19 }
sfcsSysConfigUBR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For the set operation: UBR_Cfg is set across all boards in the
chassis (that are operational and manageable).
For the get operation: UBR_Cfg setting is retrived from the
current chassis manager only (one slot only).
IF boards are introduced or re-introduced to the chassis their
UBR value will be 0. In order to insure a required UBR_Cfg value
the set operation should be proformed after slot insertions or
re-insertions are completed to the chassis. "
::= { sfcsSysConfigEnt 20 }
-- SFCS System Status Table
-- This table contains the objects that pertain to the operational status
-- of a virtual switch.
sfcsSysStatusTable OBJECT IDENTIFIER ::= { sfcsSysStatus 1 }
sfcsSysStatusEnt OBJECT IDENTIFIER ::= { sfcsSysStatusTable 1 }
sfcsSysStatusTdmCellCount OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of cells being transfered
across the TDM for the entire switch."
::= { sfcsSysStatusEnt 1 }
sfcsSysStatusTdmUtilization OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total percentage TDM utilization for the switch."
::= { sfcsSysStatusEnt 2 }
sfcsSysStatusCurrCnxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of connection entries for
this switch."
::= { sfcsSysStatusEnt 3 }
sfcsSysStatusCurrUPCEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of UPC entries for this
switch."
::= { sfcsSysStatusEnt 4 }
sfcsSysStatusCurrStatsEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of statistics entries for
this switch."
::= { sfcsSysStatusEnt 5 }
sfcsSysStatusAllocatedBw OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current allocated bandwidth of the switch in
bits per second."
::= { sfcsSysStatusEnt 6 }
-- SFCS System Configuration Table set up as a SYSTEM MIB
-- This table contains the objects that pertain to the setup and
-- configuration of the virtual switch.
sfcsSysSystemCfgTable OBJECT IDENTIFIER ::= { sfcsSysSystemCfg 1 }
sfcsSysSystemCfgEnt OBJECT IDENTIFIER ::= { sfcsSysSystemCfgTable 1 }
sfcsSysConfigAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets this virtual switch. Writing a value of
reset(2) will force a restart of the entire switch,
without any graceful shutdown. Any active
connections or services will be interrupted.
other(1) -- none of the following
reset(2) -- force a reset"
::= { sfcsSysSystemCfgEnt 1 }
sfcsSysConfigATOMPersistance OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This enables or disables ATOM mib persistance.
enabled(1)
disabled(2)"
::= { sfcsSysSystemCfgEnt 2 }
sfcsSysConfigVcSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry is the size of VCs allocated for all
VPs in the switch."
::= { sfcsSysSystemCfgEnt 3 }
sfcsSysConfigPowerUpDiags OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This enables or disables power up diags.
enabled(1)
disabled(2)"
::= { sfcsSysSystemCfgEnt 4 }
-- SFCS System Back Plane Table set up as a SYSTEM MIB
-- This table contains the objects that pertain to the setup and
-- configuration of the virtual switch.
sfcsSysBPTable OBJECT IDENTIFIER ::= { sfcsSysBPCfg 1 }
sfcsSysBPEnt OBJECT IDENTIFIER ::= { sfcsSysBPTable 1 }
sfcsSysBPClkSelect OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This enables one of two backplane clocks from any slot.
A valid entry is any number that correspond to a slot
having a board supporting this mib. A write to this mib
will fail if the board with the number selected is deriving
its clock from the backplane. A value of 0 indicates that no
board is driving the backplane."
::= { sfcsSysBPEnt 1 }
-- From here forward, all objects represent the switch modules.
-- SFCS Engine Group
-- This group contains the objects that pertain to switching engines at
-- a switch module, slot-instanced level. This group contains four sub-groups:
-- configuration status, statistics, UPC Engine, and statistics engine.
-- SFCS Engine Configuration Table
-- This table contains the objects that pertain to the setup and
-- configuration of a single SFCS module.
sfcsConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration and administrative
information for each SFCS module. Essentially, a
separate SFCS instance exists for each switch module.
If SFCS is not configured on a module, than an entry
will not exist."
::= { sfcsConfig 1 }
sfcsConfigEntry OBJECT-TYPE
SYNTAX SfcsConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the SFCS configuration for the
SFCS module."
INDEX { sfcsConfigSlotIndex }
::= { sfcsConfigTable 1 }
SfcsConfigEntry ::=
SEQUENCE {
sfcsConfigSlotIndex INTEGER,
sfcsConfigAdminStatus INTEGER,
sfcsConfigAdminReset INTEGER,
sfcsConfigOperStatus INTEGER,
sfcsConfigOperTime TimeTicks,
sfcsConfigLastChange TimeTicks,
sfcsConfigVersion INTEGER,
sfcsConfigMibRev DisplayString,
sfcsConfigSwitchHostPort INTEGER,
sfcsConfigHostCtrlATMAddr OCTET STRING,
sfcsConfigSwitchCapacity INTEGER,
sfcsConfigMaxCnxEntries INTEGER,
sfcsConfigMaxStatEntries INTEGER,
sfcsConfigMaxUpcEntries INTEGER,
sfcsConfigNumberANIMS INTEGER,
sfcsConfigBwCapability INTEGER,
sfcsConfigMasterClock1Source INTEGER,
sfcsConfigMasterClock2Source INTEGER,
sfcsConfigMasterClock1Standby INTEGER,
sfcsConfigMasterClock2Standby INTEGER
}
sfcsConfigSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index to the SFCS switch table. This
identifies the chassis slot number for this switch
module."
::= { sfcsConfigEntry 1 }
sfcsConfigAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- startup the SFCS
disabled(2), -- shutdown the SFCS
other(3) -- none of the following
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS switching
services for this SFCS module. This controls the
SFCS state at a module level. Regardless of the
per-interface state of each SFCS switching interface
and the state of active connections, writing the value
disabled(2) will cause the SFCS to immediately
shutdown. A gracefull shutdown will be attempted.
enabled(1) -- startup the SFCS
disabled(2) -- shutdown the SFCS
other(3) -- none of the following"
::= { sfcsConfigEntry 2 }
sfcsConfigAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets this SFCS module. Writing a value of
reset(2) will force a soft restart of the SFCS
without any graceful shutdown. Any active
connections or services will be interrupted.
other(1) -- none of the following
reset(2) -- force a reset"
::= { sfcsConfigEntry 3 }
sfcsConfigOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- running
disabled(2), -- not running
other(3), -- none of the following
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the SFCS
module.
enabled(1) -- running
disabled(2) -- not running
other(3) -- none of the following
pending-disable(4) -- shut-down in progress
pending-enable(5) -- start-up in progress
invalid-config(6) -- not running,invalid config"
::= { sfcsConfigEntry 4 }
sfcsConfigOperTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (# of time ticks) that this
SFCS module has been in its current operational state."
::= { sfcsConfigEntry 5 }
sfcsConfigLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the last time a change was made to the
configuration entry for this SFCS switch module."
::= { sfcsConfigEntry 6 }
sfcsConfigVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the SFCS MIB
for this switch module expressed as an integer."
::= { sfcsConfigEntry 7 }
sfcsConfigMibRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates in textual format the current revision level
of the Cabletron SFCS MIB for this switch module."
::= { sfcsConfigEntry 8 }
sfcsConfigSwitchHostPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the switch port that is attached to the host."
::= { sfcsConfigEntry 9 }
sfcsConfigHostCtrlATMAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the ATM address of the host. (SAR)"
::= { sfcsConfigEntry 10 }
sfcsConfigSwitchCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the front panel bandwidth based on the hardware
that is currently installed, in Mbps.
(number of ports and the port type)"
::= { sfcsConfigEntry 11 }
sfcsConfigMaxCnxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of connections which
can be established on this switch module."
::= { sfcsConfigEntry 12 }
sfcsConfigMaxStatEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of stats enabled VCs for this
switch module."
::= { sfcsConfigEntry 13 }
sfcsConfigMaxUpcEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum number of UPC enabled VCs for this
switch module."
::= { sfcsConfigEntry 14 }
sfcsConfigNumberANIMS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of ATM Network Inteface Modules
currently configured on this switch module."
::= { sfcsConfigEntry 15 }
sfcsConfigBwCapability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total bandwidth capability for this
switch engine expressed in Mbps."
::= { sfcsConfigEntry 16 }
sfcsConfigMasterClock1Source OBJECT-TYPE
SYNTAX INTEGER{
anim-one-clk(1),
anim-two-clk(2),
anim-three-clk(3),
anim-four-clk(4),
backplane-one(5),
backplane-two(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the clocking source for MasterClock1 on each board.
The write will fail if it is also currently the source of the
backplane. The write will also fail if the board does not support
backplane clocking."
::= { sfcsConfigEntry 17 }
sfcsConfigMasterClock2Source OBJECT-TYPE
SYNTAX INTEGER{
anim-one-clk(1),
anim-two-clk(2),
anim-three-clk(3),
anim-four-clk(4),
backplane-one(5),
backplane-two(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the clocking source for MasterClock2 on each board.
The write will fail if it is also currently the source of the
backplane. The write will also fail if the board does not support
backplane clocking."
::= { sfcsConfigEntry 18 }
sfcsConfigMasterClock1Standby OBJECT-TYPE
SYNTAX INTEGER{
anim-one-clk(1),
anim-two-clk(2),
anim-three-clk(3),
anim-four-clk(4),
backplane-one(5),
backplane-two(6),
none(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the clocking stand-by for MasterClock1 on each board.
The write will fail if it is also currently the source of the
backplane. The write will also fail if the board does not support
backplane clocking. If this value is none(7) and an interrupt on
the primary interface for MasterClock1 is received. MasterClock1
will switch to that anims local clock."
::= { sfcsConfigEntry 19 }
sfcsConfigMasterClock2Standby OBJECT-TYPE
SYNTAX INTEGER{
anim-one-clk(1),
anim-two-clk(2),
anim-three-clk(3),
anim-four-clk(4),
backplane-one(5),
backplane-two(6),
none(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the clocking stand-by for MasterClock2 on each board.
The write will fail if it is also currently the source of the
backplane. The write will also fail if the board does not support
backplane clocking. If this value is none(7) and an interrupt on
the primary interface for MasterClock1 is received. MasterClock1
will switch to that anims local clock."
::= { sfcsConfigEntry 20 }
-- SFCS Status Table
-- This table contains the objects that pertain to the operational status
-- of a single SFCS module.
sfcsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the status information for each SFCS
switch module."
::= { sfcsStatus 1 }
sfcsStatusEntry OBJECT-TYPE
SYNTAX SfcsStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SFCS statistics for the SFCS
instance."
INDEX { sfcsStatusSlotIndex }
::= { sfcsStatusTable 1 }
SfcsStatusEntry ::=
SEQUENCE {
sfcsStatusSlotIndex INTEGER,
sfcsStatusTdmCellCount OCTET STRING,
sfcsStatusTdmUtilization INTEGER,
sfcsStatusCurrCnxEntries INTEGER,
sfcsStatusCurrUPCEntries INTEGER,
sfcsStatusCurrStatsEntries INTEGER,
sfcsStatusCurrCtmAgent INTEGER
}
sfcsStatusSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index to the SFCS switch table. This
identifies the chassis slot number for this SFCS module."
::= { sfcsStatusEntry 1 }
sfcsStatusTdmCellCount OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of cells being transfered
across the TDM for this switch module."
::= { sfcsStatusEntry 2 }
sfcsStatusTdmUtilization OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the percentage TDM utilization for this switch
module."
::= { sfcsStatusEntry 3 }
sfcsStatusCurrCnxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of connection entries for
this switch module."
::= { sfcsStatusEntry 4 }
sfcsStatusCurrUPCEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of UPC entries for this
switch module."
::= { sfcsStatusEntry 5 }
sfcsStatusCurrStatsEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current number of statistics entries for
this switch module."
::= { sfcsStatusEntry 6 }
sfcsStatusCurrCtmAgent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current board number of
the ctm agent for this switch module."
::= { sfcsStatusEntry 7 }
-- SFCS UPC Engine Table
-- This table contains the objects that pertain to UPC Engine
-- monitoring and statistics of a single instance, slot number indexed
-- SFCS module.
sfcsUPCTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsUPCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the Usage Parameter Control info
for this SFCS module."
::= { sfcsUPCEngine 1 }
sfcsUPCEntry OBJECT-TYPE
SYNTAX SfcsUPCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the UPC data for the SFCS instance."
INDEX { sfcsUPCSlotIndex }
::= { sfcsUPCTable 1 }
SfcsUPCEntry ::=
SEQUENCE {
sfcsUPCSlotIndex INTEGER,
sfcsUPCAdminStatus INTEGER,
sfcsUPCOperStatus INTEGER,
sfcsUPCReset INTEGER,
sfcsUPCOperTime TimeTicks
}
sfcsUPCSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index to the SFCS switch table. This
identifies the slot number for this SFCS module."
::= { sfcsUPCEntry 1 }
sfcsUPCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS module's
UPC engine.
enabled(1)
disabled(2)
other(3)"
::= { sfcsUPCEntry 2 }
sfcsUPCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operational state of the SFCS module's
UPC engine."
::= { sfcsUPCEntry 3 }
sfcsUPCReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the UPC engine for this SFCS module.
other(1)
reset(2)"
::= { sfcsUPCEntry 4 }
sfcsUPCOperTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (# of time ticks) that
the UPC engine has been active for this switch module."
::= { sfcsUPCEntry 5 }
-- SFCS Statistics Engine Table
-- This table contains the objects that pertain to Statistics Engine
-- for a single SFCS module.
sfcsStatsEngineTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsStatsEngineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information for the Statistics engine
for a particular switch module."
::= { sfcsStatisticsEngine 1 }
sfcsStatsEngineEntry OBJECT-TYPE
SYNTAX SfcsStatsEngineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the statistics engine data for the
SFCS module."
INDEX { sfcsStatsEngineSlotIndex }
::= { sfcsStatsEngineTable 1 }
SfcsStatsEngineEntry ::=
SEQUENCE {
sfcsStatsEngineSlotIndex INTEGER,
sfcsStatsEngineAdminStatus INTEGER,
sfcsStatsEngineOperStatus INTEGER,
sfcsStatsEngineReset INTEGER,
sfcsStatsEngineOperTime TimeTicks
}
sfcsStatsEngineSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index to the SFCS stats engine table.
This identifies the chassis slot number for this SFCS
module."
::= { sfcsStatsEngineEntry 1 }
sfcsStatsEngineAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS switch
statistics engine. Writing a value of enabled(1) causes
these counters to become active for this SFCS switch
instance. Writing a value of disabled(2) causes
these counters to become inactive for this SFCS
module.
enabled(1)
disabled(2)
other(3)"
::= { sfcsStatsEngineEntry 2 }
sfcsStatsEngineOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operational state of the SFCS switch
statistics engine for this switch module.
enabled(1)
disabled(2)
other(3)"
::= { sfcsStatsEngineEntry 3 }
sfcsStatsEngineReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the SFCS switch counters for this SFCS module.
Writing a value of reset(2) resets the SFCS switch
counters to 0 and causes sfcsStatsEngineOperTime
to also be reset to 0.
other(1)
reset(2)"
::= { sfcsStatsEngineEntry 4 }
sfcsStatsEngineOperTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (# of time ticks) that
the SFCS switch statistics have been active for this
switch module."
::= { sfcsStatsEngineEntry 5 }
-- SFCS Packet Discard Engine Table
-- This table contains the objects that pertain to Packet Discard Engine
-- for a single SFCS module.
sfcsPacketDiscardEngineTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsPacketDiscardEngineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information for the Packet Discard engine
for a particular switch module."
::= { sfcsPacketDiscardEngine 1 }
sfcsPacketDiscardEngineEntry OBJECT-TYPE
SYNTAX SfcsPacketDiscardEngineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the packet discard engine data for the
SFCS module."
INDEX { sfcsPacketDiscardEngineSlotIndex }
::= { sfcsPacketDiscardEngineTable 1 }
SfcsPacketDiscardEngineEntry ::=
SEQUENCE {
sfcsPacketDiscardEngineSlotIndex INTEGER,
sfcsPacketDiscardEngineAdminStatus INTEGER,
sfcsPacketDiscardEngineOperStatus INTEGER,
sfcsPacketDiscardEngineReset INTEGER,
sfcsPacketDiscardEngineEPDPercentage INTEGER,
sfcsPacketDiscardEngineOperTime TimeTicks
}
sfcsPacketDiscardEngineSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index to the SFCS packet discard engine table.
This identifies the chassis slot number for this SFCS
module."
::= { sfcsPacketDiscardEngineEntry 1 }
sfcsPacketDiscardEngineAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS switch
packet discard engine. Writing a value of enabled(1) causes
these packet discard registers to become active for this SFCS switch
instance. Writing a value of disabled(2) causes
these packet discard registers to become inactive for this SFCS
module.
enabled(1)
disabled(2)
other(3)"
::= { sfcsPacketDiscardEngineEntry 2 }
sfcsPacketDiscardEngineOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operational state of the SFCS switch
packet discard engine for this switch module.
enabled(1)
disabled(2)
other(3)"
::= { sfcsPacketDiscardEngineEntry 3 }
sfcsPacketDiscardEngineReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the SFCS switch registers for this SFCS module.
Writing a value of reset(2) resets the SFCS switch packet
discard registers to 0 and causes sfcsPacketDiscardEngineOperTime
to also be reset to 0.
other(1)
reset(2)"
::= { sfcsPacketDiscardEngineEntry 4 }
sfcsPacketDiscardEngineEPDPercentage OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the Early Packet Discard threshold percentage for every
port, and every priority on a single blade."
::= { sfcsPacketDiscardEngineEntry 5 }
sfcsPacketDiscardEngineOperTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (# of time ticks) that
the SFCS switch packet discard engine has been active for this
switch module."
::= { sfcsPacketDiscardEngineEntry 6 }
-- SFCS Switching ANIM Group
-- This group contains the managed objects used to setup and
-- configure the SFCS ANIMS. This group contains two sub-groups:
-- configuration status and statistics.
-- SFCS ANIM Configuration Status Table
-- This table contains the managed objects used to set-up and configure
-- each SFCS ANIM.
sfcsANIMConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsANIMConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration information for
each SFCS ANIM instance."
::= { sfcsANIMConfig 1 }
sfcsANIMConfigEntry OBJECT-TYPE
SYNTAX SfcsANIMConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SFCS config info for the SFCS
instance."
INDEX { sfcsANIMConfigANIMIndex }
::= { sfcsANIMConfigTable 1 }
SfcsANIMConfigEntry ::=
SEQUENCE {
sfcsANIMConfigANIMIndex INTEGER,
sfcsANIMConfigAdminStatus INTEGER,
sfcsANIMConfigOperStatus INTEGER,
sfcsANIMConfigANIMType OBJECT IDENTIFIER,
sfcsANIMConfigNumInterfaces INTEGER,
sfcsANIMConfigLineRate INTEGER,
sfcsANIMConfigToMB INTEGER,
sfcsANIMConfigMBClockSelect INTEGER
}
sfcsANIMConfigANIMIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which ANIM we are dealing
with. This reference is in the same format as
MIB II's InterfaceIndex."
::= { sfcsANIMConfigEntry 1 }
sfcsANIMConfigAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SFCS switch
ANIM.
enabled(1)
disabled(2)
other(3)"
::= { sfcsANIMConfigEntry 2 }
sfcsANIMConfigOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
other(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operational state of the SFCS switch
ANIM for this SFCS ANIM instance.
enabled(1)
disabled(2)
other(3)"
::= { sfcsANIMConfigEntry 3 }
sfcsANIMConfigANIMType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the type of physical interface for this
ANIM. The types are described in ctron.oids"
::= { sfcsANIMConfigEntry 4 }
sfcsANIMConfigNumInterfaces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of operational interfaces for
this ANIM."
::= { sfcsANIMConfigEntry 5 }
sfcsANIMConfigLineRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the line rate per port for this ANIM in
Mbps."
::= { sfcsANIMConfigEntry 6 }
sfcsANIMConfigToMB OBJECT-TYPE
SYNTAX INTEGER {
local-anim-clock(1),
port-one-clock(2),
port-two-clock(3),
port-three-clock(4),
port-four-clock(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the ANIM clock source to board."
::= { sfcsANIMConfigEntry 7 }
sfcsANIMConfigMBClockSelect OBJECT-TYPE
SYNTAX INTEGER {
master-clk-one(1),
master-clk-two(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates the ANIM clock source."
::= { sfcsANIMConfigEntry 8 }
-- SFCS ANIM Stats Tables
-- This table contains the managed objects used to keep track of transmit
-- and receive counts and bandwidth for each SFCS ANIM.
sfcsANIMStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsANIMStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the statistics information for
each SFCS ANIM instance."
::= { sfcsANIMStatistics 1 }
sfcsANIMStatsEntry OBJECT-TYPE
SYNTAX SfcsANIMStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SFCS statistics for the SFCS
instance."
INDEX { sfcsANIMStatsANIMIndex }
::= { sfcsANIMStatsTable 1 }
SfcsANIMStatsEntry ::=
SEQUENCE {
sfcsANIMStatsANIMIndex INTEGER,
sfcsANIMStatsRxCells OCTET STRING,
sfcsANIMStatsTxCells OCTET STRING
}
sfcsANIMStatsANIMIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary index which specifies which ANIM instance
we are dealing with. This index is formatted like
MIB II's Interface Index."
::= { sfcsANIMStatsEntry 1 }
sfcsANIMStatsRxCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells received from this
ANIM's interfaces."
::= { sfcsANIMStatsEntry 2 }
sfcsANIMStatsTxCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells transmitted from
this ANIM's interfaces."
::= { sfcsANIMStatsEntry 3 }
-- SFCS ANIM Pic Table
-- This table contains the managed objects used to keep track of
-- the PIC info for each SFCS ANIM.
sfcsANIMPicTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsANIMPicEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the PIC information for
each SFCS ANIM instance."
::= { sfcsANIMPic 1 }
sfcsANIMPicEntry OBJECT-TYPE
SYNTAX SfcsANIMPicEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SFCS PIC info for the SFCS
instance."
INDEX { sfcsANIMPicIndex }
::= { sfcsANIMPicTable 1 }
SfcsANIMPicEntry ::=
SEQUENCE {
sfcsANIMPicSlot INTEGER,
sfcsANIMPicIndex INTEGER,
sfcsANIMPicLocation OBJECT IDENTIFIER,
sfcsANIMPicStatus INTEGER,
sfcsANIMPicVersion DisplayString,
sfcsANIMPicModuleType OBJECT IDENTIFIER,
sfcsANIMPicMfgPN DisplayString,
sfcsANIMPicMfgSN DisplayString,
sfcsANIMPicMfgPartNumb DisplayString,
sfcsANIMPicMfgSerialNumb DisplayString,
sfcsANIMPicMfgReworkLocation DisplayString,
sfcsANIMPicMfgMfgLocation DisplayString,
sfcsANIMPicMfgDateCode DisplayString,
sfcsANIMPicMfgRevisionCode DisplayString,
sfcsANIMPicTLPN DisplayString,
sfcsANIMPicTLSN DisplayString,
sfcsANIMPicTLPartNumb DisplayString,
sfcsANIMPicTLSerialNumb DisplayString,
sfcsANIMPicTLReworkLocation DisplayString,
sfcsANIMPicTLMfgLocation DisplayString,
sfcsANIMPicTLDateCode DisplayString,
sfcsANIMPicTLRevisionCode DisplayString,
sfcsANIMPicTLPcbRevision DisplayString,
sfcsANIMPicMacAddr OCTET STRING,
sfcsANIMPicNumbRsvdAddrs INTEGER,
sfcsANIMPicBoardLevelRevision DisplayString,
sfcsANIMPicModuleTypeString DisplayString,
sfcsANIMPicDcDcConverterType DisplayString,
sfcsANIMPicDcDcConverterInputPower DisplayString,
sfcsANIMPicSmb1PromVersion DisplayString
}
sfcsANIMPicSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specific slot which the module that realizes this PIC
resides. If the PIC is associated with the chassis
and not a specific module then this value will be 0."
::= { sfcsANIMPicEntry 1 }
sfcsANIMPicIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Uniquely identifies the instance of a PIC in a particular
slot."
::= { sfcsANIMPicEntry 2 }
sfcsANIMPicLocation OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines location of the PIC chip. This takes on any of
the encoding values defined below for backplane, module,
daughter board, brim."
::= { sfcsANIMPicEntry 3 }
sfcsANIMPicStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
present(2),
notPresent(3),
checkSum(4),
error(5),
limited(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Provides the status of the specific PIC chip. the values
are defined as follows:
other(1) - firmware can not determine status
present(2) - PIC seems to be functional
notPresent(3) - PIC not found but expected
checkSum(4) - A check sum error occured
error(5) - An undefined error condition exists.
limited(6) - A limited PIC implementation only
type code information is present."
::= { sfcsANIMPicEntry 4 }
sfcsANIMPicVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reflects the version of the PIC implementation that this
PIC conforms to. This has the format x.yy . If non-existent,
this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 5 }
sfcsANIMPicModuleType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the standard module type value as defined in
ctron-oids."
::= { sfcsANIMPicEntry 6 }
sfcsANIMPicMfgPN OBJECT-TYPE
SYNTAX DisplayString (SIZE(9))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the manufacturing level part number of the module
associated with this PIC. This information is encoded as
follows:
7 Characters Part Number
2 Characters Rework Location.
If any field of this object is non-existent, it will be set
to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 7 }
sfcsANIMPicMfgSN OBJECT-TYPE
SYNTAX DisplayString (SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the manufacturing level serial number of the module
associated with this PIC. This information is encoded as
follows:
3 bytes - Date code (year/week)
4 bytes - Serial number
2 bytes - Manufacture location
3 bytes - Board level revision
If any field of this object is non-existent, it will be
set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 8 }
sfcsANIMPicMfgPartNumb OBJECT-TYPE
SYNTAX DisplayString (SIZE(7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object presents the part number portion of the
ctPicMfgPN object. This object contains the same information
however in a more human readable format. If non-existent,
this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 9 }
sfcsANIMPicMfgSerialNumb OBJECT-TYPE
SYNTAX DisplayString (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object presents the serial number portion of the
ctPicMfgSN object. This object contains the same information
however in a more human readable format. If non-existent,
this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 10 }
sfcsANIMPicMfgReworkLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 2 character code that defines the location this
module was last reworked. This object contains the same
information as presented in ctPicMfgPN object however
in a more human readable format. If non-existent, this
object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 11 }
sfcsANIMPicMfgMfgLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The two character code that defines the location
this module was manufactured at. This object contains the same
information as presented in ctPicMfgSN object however
in a more human readable format. If non-existent, this object
will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 12 }
sfcsANIMPicMfgDateCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 3 byte date code field when this module was last
reworked. This is in year/week format. This object
contains the same information as presented in ctPicMfgSN
object however in a more human readable format. If
non-existent, this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 13 }
sfcsANIMPicMfgRevisionCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 3 character board level revision code field of this
module. This object contains the same information as
presented in ctPicMfgSN object however in a more human
readable format. If non-existent, this object will be set
to all blanks (ascii 32)."
::= { sfcsANIMPicEntry 14 }
sfcsANIMPicTLPN OBJECT-TYPE
SYNTAX DisplayString (SIZE(9))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the top level part number of the module associated
with this PIC. This information is encoded as follows:
7 Characters Part Number
2 Characters Rework Location.
If any field of this object is non-existent, it will be set
to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 15 }
sfcsANIMPicTLSN OBJECT-TYPE
SYNTAX DisplayString (SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the top level serial number of the module
associated with this PIC. This information is encoded
as follows:
3 bytes - Date code (year/week)
4 bytes - Serial number
2 bytes - Manufacture location
3 bytes - Top level revision
If any field of this object is non-existent, it will be
set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 16 }
sfcsANIMPicTLPartNumb OBJECT-TYPE
SYNTAX DisplayString (SIZE(7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object presents the part number portion of the
ctPicTLPN object. This object contains the same information
however in a more human readable format. If non-existent,
this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 17 }
sfcsANIMPicTLSerialNumb OBJECT-TYPE
SYNTAX DisplayString (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object presents the serial number portion of the
ctPicTLSN object. This object contains the same information
however in a more human readable format. If non-existent,
this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 18 }
sfcsANIMPicTLReworkLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 2 character code that defines the location this
module was last reworked. This object contains the same
information as presented in ctPicTLPN object however
in a more human readable format. If non-existent, this
object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 19 }
sfcsANIMPicTLMfgLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The two character code that defines the location
this module was manufactured at. This object contains the same
information as presented in ctPicTLSN object however
in a more human readable format. If non-existent, this object
will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 20 }
sfcsANIMPicTLDateCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 3 byte date code field when this module was last
reworked. This is in year/week format. This object
contains the same information as presented in ctPicTLSN
object however in a more human readable format. If
non-existent, this object will be set to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 21 }
sfcsANIMPicTLRevisionCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 3 character top level revision code field of this module.
This object contains the same information as presented in
ctPicTLSN object however in a more human readable format.
If non-existent, this object will be set to all blanks
(ascii 32)."
::= { sfcsANIMPicEntry 22 }
sfcsANIMPicTLPcbRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the Cabletron revision of the art work for this
module. If non-existent, this object will be set to all
blanks(ascii 32)."
::= { sfcsANIMPicEntry 23 }
sfcsANIMPicMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The base MAC address(ethernet format)assigned to the module.
If this field is not used then it should have a value of a
zero length string. If non-existent, this object will be set
to all blanks(ascii 32)."
::= { sfcsANIMPicEntry 24 }
sfcsANIMPicNumbRsvdAddrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of reserved MAC addresses starting at the
address as defined in ctPicMacAddr. If no MAC addresses
are reserved this object should have a value of 0."
::= { sfcsANIMPicEntry 25 }
sfcsANIMPicBoardLevelRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the Cabletron board level revision level code for
this module. If non-existent, this object will be set to
blanks (ascii 32)."
::= { sfcsANIMPicEntry 26 }
sfcsANIMPicModuleTypeString OBJECT-TYPE
SYNTAX DisplayString (SIZE(16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the module associated with this PIC in a
human readable format. If non-existent, this object
will be set to blanks (ascii 32)."
::= { sfcsANIMPicEntry 27 }
sfcsANIMPicDcDcConverterType OBJECT-TYPE
SYNTAX DisplayString (SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the voltage of the installed DCDC Converter
input and output lines.
If the Module does not contain a DCDC Converter
this object will be set to blanks (ascii 32)."
::= { sfcsANIMPicEntry 28 }
sfcsANIMPicDcDcConverterInputPower OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the maximum allowed input power
for the DCDC input line.
If the Module does not contain a DCDC Converter
this object will be set to blanks (ascii 32)."
::= { sfcsANIMPicEntry 29 }
sfcsANIMPicSmb1PromVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the current version of the SMB1 prom.
If the Module does not contain an SMB1 prom
this object will be set to blanks (ascii 32)."
::= { sfcsANIMPicEntry 30 }
-- SFCS Switching Interface Group
-- This group contains the managed objects used to setup and
-- configure the SFCS interfaces for cell switching and statisics
-- monitoring. This group contains two sub-groups: configuration
-- and statistics.
-- SFCS Interface Configuration Table
-- This table contains the managed objects used to set-up and configure
-- each SFCS switching interface.
sfcsInterfaceConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsInterfaceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration information of each
configured SFCS switch interface. If SFCS is not configured
on a port, than an entry will not exist."
::= { sfcsInterfaceConfig 1 }
sfcsInterfaceConfigEntry OBJECT-TYPE
SYNTAX SfcsInterfaceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the SFCS configuration for the SFCS
switch interface for which the entry exists."
INDEX { sfcsInterfaceConfigInterfaceIndex }
::= { sfcsInterfaceConfigTable 1 }
SfcsInterfaceConfigEntry ::=
SEQUENCE {
sfcsInterfaceConfigInterfaceIndex INTEGER,
sfcsInterfaceConfigType INTEGER,
sfcsInterfacePeakBufferUseage INTEGER,
sfcsInterfaceConfigNumberOfQueues INTEGER,
sfcsInterfaceConfigSigStackID INTEGER,
sfcsInterfaceConfigClockingSource INTEGER
}
sfcsInterfaceConfigInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsInterfaceConfigEntry 1 }
sfcsInterfaceConfigType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
access-port(2),
network-port(3),
host-mgmt-port(4),
host-ctl-port(5)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Sets the type of interface access attribute for the SFCS
interfaces. Access ports allow single user or shared
access and perform statisics and control; network ports
are equivalent to trunk ports with no access control;
host management port indicates the (virtual) port to which
the (internal) management agent is attached; host control
port indicates the port to redirect non-management packets.
other(1)
access-port(2)
network-port(3)
host-mgmt-port(4)
host-ctl-port(5)"
::= { sfcsInterfaceConfigEntry 2 }
sfcsInterfacePeakBufferUseage OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An accumulated snap shot of the current peak queue depth
for the configured buffer queues. This information is
obtained from a read/reset register."
::= { sfcsInterfaceConfigEntry 3 }
sfcsInterfaceConfigNumberOfQueues OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of priority queues configured on this
interface."
::= { sfcsInterfaceConfigEntry 4 }
sfcsInterfaceConfigSigStackID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the user signalling stack ID for this interface."
::= { sfcsInterfaceConfigEntry 5 }
sfcsInterfaceConfigClockingSource OBJECT-TYPE
SYNTAX INTEGER {
local-anim-clock(1),
mother-board-master-clock(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interface clocking source."
::= { sfcsInterfaceConfigEntry 6 }
-- SFCS Switching Interface Statistics Tables
-- This table contains the objects that specify the packet and byte counters
-- for each configured SFCS switching interface.
sfcsInterfaceStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsInterfaceStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the cell counts for each
SFCS switch interface."
::= { sfcsInterfaceStatistics 1 }
sfcsInterfaceStatsEntry OBJECT-TYPE
SYNTAX SfcsInterfaceStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the SFCS cell counts for the SFCS
interface for which this entry exists."
INDEX { sfcsInterfaceStatsInterfaceIndex }
::= { sfcsInterfaceStatsTable 1 }
SfcsInterfaceStatsEntry ::=
SEQUENCE {
sfcsInterfaceStatsInterfaceIndex INTEGER,
sfcsInterfaceStatsRxErrors OCTET STRING,
sfcsInterfaceStatsVPILookupInvalidErrors OCTET STRING,
sfcsInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING,
sfcsInterfaceStatsRxCellCnt OCTET STRING,
sfcsInterfaceStatsTxCellCnt OCTET STRING,
sfcsInterfaceStatsOverflowDropCellCnt OCTET STRING
}
sfcsInterfaceStatsInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsInterfaceStatsEntry 1 }
sfcsInterfaceStatsRxErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive path lookup
invalid and out of range errors."
::= { sfcsInterfaceStatsEntry 2 }
sfcsInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of VPI lookup invalid and out of
range errors."
::= { sfcsInterfaceStatsEntry 3 }
sfcsInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive connection lookup
invalid errors."
::= { sfcsInterfaceStatsEntry 4 }
sfcsInterfaceStatsRxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive cells on
this interface."
::= { sfcsInterfaceStatsEntry 5 }
sfcsInterfaceStatsTxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of transmit cells
on this interface."
::= { sfcsInterfaceStatsEntry 6 }
sfcsInterfaceStatsOverflowDropCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells that were
dropped due to queue overflows."
::= { sfcsInterfaceStatsEntry 7 }
-- SFCS Switch Queue Group
-- This group contains the managed objects for maintaining SFCS Queues.
-- SFCS Queue Configuration Table
sfcsQueueConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsQueueConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration information for
all queues on the SFCS."
::= { sfcsQueueConfig 1 }
sfcsQueueConfigEntry OBJECT-TYPE
SYNTAX SfcsQueueConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the queue information for the
SFCS switch for which the entry exists."
INDEX { sfcsQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex }
::= { sfcsQueueConfigTable 1 }
SfcsQueueConfigEntry ::=
SEQUENCE {
sfcsQueueConfigInterfaceIndex INTEGER,
sfcsQueueConfigQueueIndex INTEGER,
sfcsQueueConfigQueueSize INTEGER,
sfcsQueueConfigQueueBandwidth INTEGER,
sfcsQueueConfigClpDropThreshold INTEGER,
sfcsQueueConfigCongestionThreshold INTEGER,
sfcsQueueConfigEFCILowThreshold INTEGER,
sfcsQueueConfigRMThreshold INTEGER,
sfcsQueueConfigEPDThreshold INTEGER
}
sfcsQueueConfigInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsQueueConfigEntry 1 }
sfcsQueueConfigQueueIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which transmit queue we
are dealing with."
::= { sfcsQueueConfigEntry 2 }
sfcsQueueConfigQueueSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the size of the transmit queue for this
queue instance."
::= { sfcsQueueConfigEntry 3 }
sfcsQueueConfigQueueBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the percentage of this interface's bandwidth
utilized by this particular queue."
::= { sfcsQueueConfigEntry 4 }
sfcsQueueConfigClpDropThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the queue level to start dropping CLP=1
cells for this queue. This level is expressed as
the percentage of this queue's size."
::= { sfcsQueueConfigEntry 5 }
sfcsQueueConfigCongestionThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the level to consider this queue congested.
This level is expressed as the percentage of this
queue's size."
::= { sfcsQueueConfigEntry 6 }
sfcsQueueConfigEFCILowThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the lower threshold used for EFCI for
this queue instance. This level is expressed as
the percentage of this queue's size."
::= { sfcsQueueConfigEntry 7 }
sfcsQueueConfigRMThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the remote management queue threshold expressed
as a percentage of the queue's size. When this level is
hit, a management message is sent to the sender notifying it
to slow down."
::= { sfcsQueueConfigEntry 8 }
sfcsQueueConfigEPDThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the Early Packet Discard threshold expressed
as a percentage of the queue's size. When this level is
exceeded the Transmit ASIC starts to drop all cells entering
this queue."
::= { sfcsQueueConfigEntry 9 }
-- SFCS Queue Stats Table
sfcsQueueStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsQueueStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the statistics information for all
queues on the SFCS."
::= { sfcsQueueStatistics 1 }
sfcsQueueStatsEntry OBJECT-TYPE
SYNTAX SfcsQueueStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the queue information for the
SFCS switch for which the entry exists."
INDEX { sfcsQueueStatsInterfaceIndex, sfcsQueueStatsQueue }
::= { sfcsQueueStatsTable 1 }
SfcsQueueStatsEntry ::=
SEQUENCE {
sfcsQueueStatsInterfaceIndex INTEGER,
sfcsQueueStatsQueue INTEGER,
sfcsQueueStatsTxClpCellsDiscarded OCTET STRING,
sfcsQueueStatsTxCellsDropped OCTET STRING,
sfcsQueueStatsQueuePeakLevel INTEGER,
sfcsQueueStatsTxCellCnt OCTET STRING
}
sfcsQueueStatsInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsQueueStatsEntry 1 }
sfcsQueueStatsQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which queue we are
dealing with."
::= { sfcsQueueStatsEntry 2 }
sfcsQueueStatsTxClpCellsDiscarded OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells with CLP=1 that were
discarded for this queue instance."
::= { sfcsQueueStatsEntry 3 }
sfcsQueueStatsTxCellsDropped OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells that overflowed the
buffer for this queue instance."
::= { sfcsQueueStatsEntry 4 }
sfcsQueueStatsQueuePeakLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the peak level since last read for this
queue instance."
::= { sfcsQueueStatsEntry 5 }
sfcsQueueStatsTxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the transmit cell count on a per queue basis.
A value of zero indicates not available"
::= { sfcsQueueStatsEntry 6 }
-- The SFCS Connection Group
-- SFCS Switch Connection Config Table
sfcsCnxCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCnxCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the connection configuration
information."
::= { sfcsConnectionConfig 1 }
sfcsCnxCfgEntry OBJECT-TYPE
SYNTAX SfcsCnxCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the connection configuration
information for the SFCS switch connection instance."
INDEX { sfcsCnxCfgCrossConnectIndex,
sfcsCnxCfgCrossConnectLowIfIndex,
sfcsCnxCfgCrossConnectLowVpi,
sfcsCnxCfgCrossConnectLowVci,
sfcsCnxCfgCrossConnectHighIfIndex,
sfcsCnxCfgCrossConnectHighVpi,
sfcsCnxCfgCrossConnectHighVci }
::= { sfcsCnxCfgTable 1 }
SfcsCnxCfgEntry ::=
SEQUENCE {
sfcsCnxCfgCrossConnectIndex INTEGER,
sfcsCnxCfgCrossConnectLowIfIndex INTEGER,
sfcsCnxCfgCrossConnectLowVpi INTEGER,
sfcsCnxCfgCrossConnectLowVci INTEGER,
sfcsCnxCfgCrossConnectHighIfIndex INTEGER,
sfcsCnxCfgCrossConnectHighVpi INTEGER,
sfcsCnxCfgCrossConnectHighVci INTEGER,
sfcsCnxCfgType INTEGER,
sfcsCnxCfgTmType INTEGER,
sfcsCnxCfgUPCEnable INTEGER,
sfcsCnxCfgStatsEnable INTEGER,
sfcsCnxCfgStatsTableCounterSizes INTEGER,
sfcsCnxCfgOwner INTEGER
}
sfcsCnxCfgCrossConnectIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value to identify this cross-connect."
::= { sfcsCnxCfgEntry 1 }
sfcsCnxCfgCrossConnectLowIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low
MIB II IfIndex value of the ATM interface port
for this cross-connect."
::= { sfcsCnxCfgEntry 2 }
sfcsCnxCfgCrossConnectLowVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low VPI
value at the ATM interface associated with the
cross-connect that is identified by
sfcsCnxCfgCrossConnectIndex."
::= { sfcsCnxCfgEntry 3 }
sfcsCnxCfgCrossConnectLowVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low VCI
value at the ATM interface associated with this
cross-connect that is identified by
sfcsCnxCfgCrossConnectIndex."
::= { sfcsCnxCfgEntry 4 }
sfcsCnxCfgCrossConnectHighIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high
MIB II IfIndex value of the ATM interface port
for this cross-connect."
::= { sfcsCnxCfgEntry 5 }
sfcsCnxCfgCrossConnectHighVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high VPI
value at the ATM interface associated with the
cross-connect that is identified by
sfcsCnxCfgCrossConnectIndex."
::= { sfcsCnxCfgEntry 6 }
sfcsCnxCfgCrossConnectHighVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high VCI
value at the ATM interface associated with this
cross-connect that is identified by
sfcsCnxCfgCrossConnectIndex."
::= { sfcsCnxCfgEntry 7 }
sfcsCnxCfgType OBJECT-TYPE
SYNTAX INTEGER {
point-to-point-vpl (1),
point-to-mpoint-vpl (2),
mpoint-to-mpoint-vpl (3),
point-to-point-vcl (4),
point-to-mpoint-vcl (5),
mpoint-to-mpoint-vcl (6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the connection type for this VC.
point-to-point-vpl(1)
point-to-mpoint-vpl(2)
mpoint-to-mpoint-vpl(3)
point-to-point-vcl(4)
point-to-mpoint-vcl(5)
mpoint-to-mpoint-vcl(6)"
::= { sfcsCnxCfgEntry 8 }
sfcsCnxCfgTmType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
efci (2),
er (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the type of traffic management used on this VC.
other (1)
efci (2)
er (3)"
::= { sfcsCnxCfgEntry 9 }
sfcsCnxCfgUPCEnable OBJECT-TYPE
SYNTAX INTEGER {
l-h-upc-enabled (1),
l-h-tag-enabled (2),
l-h-upc-tag-enabled (3),
h-l-upc-enabled (4),
l-h-upc-and-h-l-upc-enabled (5),
l-h-Tag-and-h-l-upc-enabled (6),
l-h-upc-tag-and-h-l-upc-enabled (7),
h-l-tag-enabled (8),
l-h-upc-and-h-l-tag-enabled (9),
l-h-tag-and-h-l-tag-enabled (10),
l-h-upc-tag-and-h-l-tag-enabled (11),
h-l-upc-tag-enabled (12),
l-h-upc-and-h-l-upc-tag-enabled (13),
l-h-tag-and-h-l-upc-tag-enabled (14),
l-h-upc-tag-and-h-l-upc-tag-enabled (15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not UPC policing is enabled on
this VC. A VC can be bi-directional or uni-directional.
Due to this, the UPC bit is a masking based on directionality.
Where direction is in terms of high interface (H) and low
interface (L). (Where not specified, assume disabled.)
L to H UPC enabled(1)
L to H Tagging enabled(2)
L to H UPC/Tagging enabled(3)
H to L UPC enabled(4)
L to H UPC enabled & H to L UPC enabled(5)
L to H Tagging enabled & H to L UPC enabled(6)
L to H UPC/Tagging enabled & H to L UPC enabled(7)
H to L Tagging enabled(8)
L to H UPC enabled & H to L Tagging enabled(9)
L to H Tagging enabled & H to L Tagging enabled(10)
L to H UPC/Tagging enabled & H to L Tagging enabled(11)
H to L UPC/Tagging enabled(12)
L to H UPC enabled & H to L UPC/Tagging enabled(13)
L to H Tagging enabled and H to L UPC/Tagging enabled(14)
L to H UPC/Tagging enabled & H to L UPC/Tagging enabled(15)"
::= { sfcsCnxCfgEntry 10 }
sfcsCnxCfgStatsEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2),
other (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether statistics will be kept on this VC.
enabled(1)
disabled(2)
other(3)"
::= { sfcsCnxCfgEntry 11 }
sfcsCnxCfgStatsTableCounterSizes OBJECT-TYPE
SYNTAX INTEGER {
thirtytwobittagcounter (1),
thirtytwobitdropcounter (2),
sixteenbiteachcounter (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the size of the drop counter for this VC.
thirtytwobittagcounter (1)
thirtytwobitdropcounter (2)
sixteenbiteachcounter (3)"
::= { sfcsCnxCfgEntry 12 }
sfcsCnxCfgOwner OBJECT-TYPE
SYNTAX INTEGER {
other (1),
own (2),
dontown (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the owner of this cross connect.
other(1)
own(2)
dontown(3)"
::= { sfcsCnxCfgEntry 13 }
-- SFCS Switch Connection Stats Table
sfcsCnxStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCnxStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the connection configuration
information."
::= { sfcsConnectionStatistics 1 }
sfcsCnxStatsEntry OBJECT-TYPE
SYNTAX SfcsCnxStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the connection statistics
information for the SFCS switch connection instance."
INDEX { sfcsCnxStatsCrossConnectIndex,
sfcsCnxStatsCrossConnectLowIfIndex,
sfcsCnxStatsCrossConnectLowVpi,
sfcsCnxStatsCrossConnectLowVci,
sfcsCnxStatsCrossConnectHighIfIndex,
sfcsCnxStatsCrossConnectHighVpi,
sfcsCnxStatsCrossConnectHighVci }
::= { sfcsCnxStatsTable 1 }
SfcsCnxStatsEntry ::=
SEQUENCE {
sfcsCnxStatsCrossConnectIndex INTEGER,
sfcsCnxStatsCrossConnectLowIfIndex INTEGER,
sfcsCnxStatsCrossConnectLowVpi INTEGER,
sfcsCnxStatsCrossConnectLowVci INTEGER,
sfcsCnxStatsCrossConnectHighIfIndex INTEGER,
sfcsCnxStatsCrossConnectHighVpi INTEGER,
sfcsCnxStatsCrossConnectHighVci INTEGER,
sfcsCnxStatsLoToHiHTxCells OCTET STRING,
sfcsCnxStatsLoToHiDroppedCells OCTET STRING,
sfcsCnxStatsLoToHiTaggedCells OCTET STRING,
sfcsCnxStatsHiToLoHTxCells OCTET STRING,
sfcsCnxStatsHiToLoDroppedCells OCTET STRING,
sfcsCnxStatsHiToLoTaggedCells OCTET STRING
}
sfcsCnxStatsCrossConnectIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value to identify this cross-connect."
::= { sfcsCnxStatsEntry 1 }
sfcsCnxStatsCrossConnectLowIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low
MIB II IfIndex value of the ATM interface port
for this cross-connect."
::= { sfcsCnxStatsEntry 2 }
sfcsCnxStatsCrossConnectLowVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low VPI
value at the ATM interface associated with the
cross-connect that is identified by
sfcsCnxStatsCrossConnectIndex."
::= { sfcsCnxStatsEntry 3 }
sfcsCnxStatsCrossConnectLowVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the low VCI
value at the ATM interface associated with this
cross-connect that is identified by
sfcsCnxStatsCrossConnectIndex."
::= { sfcsCnxStatsEntry 4 }
sfcsCnxStatsCrossConnectHighIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high
MIB II IfIndex value of the ATM interface port
for this cross-connect."
::= { sfcsCnxStatsEntry 5 }
sfcsCnxStatsCrossConnectHighVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high VPI
value at the ATM interface associated with the
cross-connect that is identified by
sfcsCnxStatsCrossConnectIndex."
::= { sfcsCnxStatsEntry 6 }
sfcsCnxStatsCrossConnectHighVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is equal to the high VCI
value at the ATM interface associated with this
cross-connect that is identified by
sfcsCnxStatsCrossConnectIndex."
::= { sfcsCnxStatsEntry 7 }
sfcsCnxStatsLoToHiHTxCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the transmitted cell count for this connection.
This entry specifies the count from the low port/vpi/vci
to the high port/vpi/vci"
::= { sfcsCnxStatsEntry 8 }
sfcsCnxStatsLoToHiDroppedCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the dropped cell count for this connection
instance. This entry specifies the count from the low
port/vpi/vci to the high port/vpi/vci."
::= { sfcsCnxStatsEntry 9 }
sfcsCnxStatsLoToHiTaggedCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the tagged cell count for this connection
instance. This entry specifies the count from the low
port/vpi/vci to the high port/vpi/vci."
::= { sfcsCnxStatsEntry 10 }
sfcsCnxStatsHiToLoHTxCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the transmitted cell count for this connection.
This entry specifies the count from the high port/vpi/vci
to the low port/vpi/vci"
::= { sfcsCnxStatsEntry 11 }
sfcsCnxStatsHiToLoDroppedCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the dropped cell count for this connection
instance. This entry specifies the count from the high
port/vpi/vci to the low port/vpi/vci."
::= { sfcsCnxStatsEntry 12 }
sfcsCnxStatsHiToLoTaggedCells OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the tagged cell count for this connection
instance. This entry specifies the count from the high
port/vpi/vci to the low port/vpi/vci."
::= { sfcsCnxStatsEntry 13 }
-- SFCS Switch Connection Error Table
sfcsCnxErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCnxErrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the connection error information
supplied by the atmAPI mib."
::= { sfcsConnectionError 1 }
sfcsCnxErrorEntry OBJECT-TYPE
SYNTAX SfcsCnxErrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of VCC connection request failures. This table
is indexed the same way as the atmVcCrossConnectTable
in the AToM mib."
INDEX { atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex, atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci, atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi, atmVcCrossConnectHighVci }
-- AUGMENTS { sfcsCnxCfgEntry }
::= { sfcsCnxErrorTable 1 }
SfcsCnxErrorEntry ::=
SEQUENCE {
sfcsCnxErrorCode OCTET STRING,
sfcsCnxErrorTimeStamp TimeTicks,
sfcsCnxErrorRowStatus INTEGER
}
sfcsCnxErrorCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the error reason for failure of the
connection setup.
01 fatal_error
02 moe_table_out_of_range
03 moe_mem_not_allocated
04 mem_fetch_double_reqst
05 lo_port_invalid
06 lo_port_locked
07 lo_vpi_invalid
08 lo_vci_invalid
09 hi_port_invalid
10 hi_port_locked
11 hi_vpi_invalid
12 hi_vci_invalid
13 trfc_desc_l2h_invalid
14 trfc_desc_h2l_invalid
15 ccid_invalid
16 ccid_not_assigned
17 atm_api_type_invalid
18 atm_api_verb_invalid
19 pt_to_pt_over_write_reqst
20 pt_reqst_over_mpt_conn
21 mask_table_full
22 duplicate_request
23 moe_table_out_of_memory
24 vpi0_non_term_reqst
25 hardware_out_of_heap
26 tx_conn_table_out_of_mem
27 tx_conn_table_time_out
28 ctm_communication_error
29 connection_table_out_of_sync
30 invalid_connection_entry
31 ctm_resource_alloc_error
32 front_panel_bandwidth_alloc_error
33 ccid_in_use"
::= { sfcsCnxErrorEntry 1 }
sfcsCnxErrorTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of the sysUpTime when this
connection request failed. We will support this
field only if the element management uses this
table."
::= { sfcsCnxErrorEntry 2 }
sfcsCnxErrorRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other (1),
inactive (2),
active (3),
delete (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The administrative control of this entry. The owner
could delete this entry after reading it, to prevent
this table from growing too big.
other (1)
inactive (2)
active (3)
delete (4)"
::= { sfcsCnxErrorEntry 3 }
-- The SFCS connection API Group
sfcsCnxAPIEntry OBJECT-TYPE
SYNTAX INTEGER (1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"
The connection API leaf provides a method for contool for creating
PVCs. This always returns a value of 0.
"
::= { sfcsConnectionAPI 1 }
-- The SFCS Switch CTM Group
sfcsCTMInterfaceConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCTMInterfaceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration information of each
configured SHEMP interface. If SFCS is not configured
on a port, than an entry will not exist."
::= { sfcsCTMInterfaceConfig 1 }
sfcsCTMInterfaceConfigEntry OBJECT-TYPE
SYNTAX SfcsCTMInterfaceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the SFCS configuration for the SFCS
switch interface for which the entry exists."
INDEX { sfcsCTMInterfaceConfigInterfaceIndex }
::= { sfcsCTMInterfaceConfigTable 1 }
SfcsCTMInterfaceConfigEntry ::=
SEQUENCE {
sfcsCTMInterfaceConfigInterfaceIndex INTEGER,
sfcsCTMInterfaceConfigType INTEGER,
sfcsCTMInterfacePeakBufferUseage INTEGER,
sfcsCTMInterfaceConfigNumberOfQueues INTEGER,
sfcsCTMInterfaceConfigSigStackID INTEGER,
sfcsCTMInterfaceConfigClocking INTEGER,
sfcsCTMInterfaceConfigNextVPI INTEGER,
sfcsCTMInterfaceConfigNextVCI INTEGER
}
sfcsCTMInterfaceConfigInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsCTMInterfaceConfigEntry 1 }
sfcsCTMInterfaceConfigType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
access-port(2),
network-port(3),
host-mgmt-port(4),
host-ctl-port(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sets the type of interface access attribute for the SFCS
interfaces. Access ports allow single user or shared
access and perform statisics and control; network ports
are equivalent to trunk ports with no access control;
host management port indicates the (virtual) port to which
the (internal) management agent is attached; host control
port indicates the port to redirect non-management packets.
other(1),
access-port(2),
network-port(3),
host-mgmt-port(4),
host-ctl-port(5)
"
::= { sfcsCTMInterfaceConfigEntry 2 }
sfcsCTMInterfacePeakBufferUseage OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells in transmit buffer memory."
::= { sfcsCTMInterfaceConfigEntry 3 }
sfcsCTMInterfaceConfigNumberOfQueues OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of priority queues configured on this
interface."
::= { sfcsCTMInterfaceConfigEntry 4 }
sfcsCTMInterfaceConfigSigStackID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the user signalling stack ID for this interface."
::= { sfcsCTMInterfaceConfigEntry 5 }
sfcsCTMInterfaceConfigClocking OBJECT-TYPE
SYNTAX INTEGER {
generated-transmit-clock(1),
channel-recovered-clock(2),
system-master-clock(3),
not-supported(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The anim clocking source.
one - use the generated-transmit-clock
two - use the channel-recovered-clock
three - use the system-master-clock
four - option not supported by this interface"
::= { sfcsCTMInterfaceConfigEntry 6 }
sfcsCTMInterfaceConfigNextVPI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the next vpi for this interface."
::= { sfcsCTMInterfaceConfigEntry 7 }
sfcsCTMInterfaceConfigNextVCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the next vci for this interface."
::= { sfcsCTMInterfaceConfigEntry 8 }
-- SFCS SHEMP Interface Statistics Tables
-- This table contains the objects that specify the packet and byte counters
-- for each configured SFCS switching interface.
sfcsCTMInterfaceStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCTMInterfaceStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the cell counts for each
SFCS switch interface."
::= { sfcsCTMInterfaceStatistics 1 }
sfcsCTMInterfaceStatsEntry OBJECT-TYPE
SYNTAX SfcsCTMInterfaceStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the SFCS cell counts for the SFCS
interface for which this entry exists."
INDEX { sfcsCTMInterfaceStatsInterfaceIndex }
::= { sfcsCTMInterfaceStatsTable 1 }
SfcsCTMInterfaceStatsEntry ::=
SEQUENCE {
sfcsCTMInterfaceStatsInterfaceIndex INTEGER,
sfcsCTMInterfaceStatsRxErrors OCTET STRING,
sfcsCTMInterfaceStatsVPILookupInvalidErrors OCTET STRING,
sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING,
sfcsCTMInterfaceStatsRxCellCnt OCTET STRING,
sfcsCTMInterfaceStatsTxCellCnt OCTET STRING,
sfcsCTMInterfaceStatsOverflowDropCellCnt OCTET STRING
}
sfcsCTMInterfaceStatsInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsCTMInterfaceStatsEntry 1 }
sfcsCTMInterfaceStatsRxErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive path lookup
invalid and out of range errors."
::= { sfcsCTMInterfaceStatsEntry 2 }
sfcsCTMInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of VPI lookup invalid and out of
range errors."
::= { sfcsCTMInterfaceStatsEntry 3 }
sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive connection lookup
invalid errors."
::= { sfcsCTMInterfaceStatsEntry 4 }
sfcsCTMInterfaceStatsRxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of receive cells on
this interface."
::= { sfcsCTMInterfaceStatsEntry 7 }
sfcsCTMInterfaceStatsTxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of transmit cells
on this interface."
::= { sfcsCTMInterfaceStatsEntry 8 }
sfcsCTMInterfaceStatsOverflowDropCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells that were
dropped due to queue overflows."
::= { sfcsCTMInterfaceStatsEntry 9 }
-- SFCS SHEMP Queue Group
-- This group contains the managed objects for maintaining SFCS Shemp Queues.
-- SFCS Shemp Queue Configuration Table
sfcsCTMQueueConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCTMQueueConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the configuration information for
all queues on the SFCS."
::= { sfcsCTMQueueConfig 1 }
sfcsCTMQueueConfigEntry OBJECT-TYPE
SYNTAX SfcsCTMQueueConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the queue information for the
SFCS switch for which the entry exists."
INDEX { sfcsCTMQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex }
::= { sfcsCTMQueueConfigTable 1 }
SfcsCTMQueueConfigEntry ::=
SEQUENCE {
sfcsCTMQueueConfigInterfaceIndex INTEGER,
sfcsCTMQueueConfigQueueIndex INTEGER,
sfcsCTMQueueConfigQueueSize INTEGER,
sfcsCTMQueueConfigQueueBandwidth INTEGER,
sfcsCTMQueueConfigClpDropThreshold INTEGER,
sfcsCTMQueueConfigCongestionThreshold INTEGER,
sfcsCTMQueueConfigEFCILowThreshold INTEGER,
sfcsCTMQueueConfigRMThreshold INTEGER
}
sfcsCTMQueueConfigInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsCTMQueueConfigEntry 1 }
sfcsCTMQueueConfigQueueIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which transmit queue we
are dealing with."
::= { sfcsCTMQueueConfigEntry 2 }
sfcsCTMQueueConfigQueueSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the size of the transmit queue for this
queue instance."
::= { sfcsCTMQueueConfigEntry 3 }
sfcsCTMQueueConfigQueueBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the percentage of this interface's bandwidth
utilized by this particular queue."
::= { sfcsCTMQueueConfigEntry 4 }
sfcsCTMQueueConfigClpDropThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the queue level to start dropping CLP=1
cells for this queue. This level is expressed as
the percentage of this queue's size."
::= { sfcsCTMQueueConfigEntry 5 }
sfcsCTMQueueConfigCongestionThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the level to consider this queue congested.
This level is expressed as the percentage of this
queue's size."
::= { sfcsCTMQueueConfigEntry 6 }
sfcsCTMQueueConfigEFCILowThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the lower threshold used for EFCI for
this queue instance. This level is expressed as
the percentage of this queue's size."
::= { sfcsCTMQueueConfigEntry 7 }
sfcsCTMQueueConfigRMThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the remote management queue threshold expressed
as a percentage of the queue's size. When this level is
hit, a management message is sent to the sender notifying it
to slow down."
::= { sfcsCTMQueueConfigEntry 8 }
-- SFCS Shemp Queue Stats Table
sfcsCTMQueueStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsCTMQueueStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the statistics information for all
queues on the SFCS."
::= { sfcsCTMQueueStatistics 1 }
sfcsCTMQueueStatsEntry OBJECT-TYPE
SYNTAX SfcsCTMQueueStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the queue information for the
SFCS switch for which the entry exists."
INDEX { sfcsCTMQueueStatsInterfaceIndex, sfcsQueueStatsQueue }
::= { sfcsCTMQueueStatsTable 1 }
SfcsCTMQueueStatsEntry ::=
SEQUENCE {
sfcsCTMQueueStatsInterfaceIndex INTEGER,
sfcsCTMQueueStatsQueue INTEGER,
sfcsCTMQueueStatsTxClpCellsDiscarded OCTET STRING,
sfcsCTMQueueStatsTxCellsDropped OCTET STRING,
sfcsCTMQueueStatsQueuePeakLevel INTEGER,
sfcsCTMQueueStatsTxCellCnt OCTET STRING
}
sfcsCTMQueueStatsInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which interface we are
dealing with."
::= { sfcsCTMQueueStatsEntry 1 }
sfcsCTMQueueStatsQueue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index which specifies which queue we are
dealing with."
::= { sfcsCTMQueueStatsEntry 2 }
sfcsCTMQueueStatsTxClpCellsDiscarded OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells with CLP=1 that were
discarded for this queue instance."
::= { sfcsCTMQueueStatsEntry 3 }
sfcsCTMQueueStatsTxCellsDropped OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of cells that overflowed the
buffer for this queue instance."
::= { sfcsCTMQueueStatsEntry 4 }
sfcsCTMQueueStatsQueuePeakLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the peak level since last read for this
queue instance."
::= { sfcsCTMQueueStatsEntry 5 }
sfcsCTMQueueStatsTxCellCnt OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the transmit cell count on a per queue basis.
A value of zero indicates not available"
::= { sfcsCTMQueueStatsEntry 6 }
-- The SFCS Switch Host Group
-- The SFCS Switch UniMux Group
-- SFCS Switch Bandwidth Management Group
-- This group contains the managed objects and functions used to setup and
-- configure the SFCS Bandwidth Manager. This group contains four sub-groups
-- Nim Tables, Port Tables, Bandwidth Pool elements and Buffer Tables.
-- SFCS ANIM Bandwidth Management Nim Table
-- This table contains contains information about the administration status of the Nim.
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Nim Information
sfcsBwNimsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBwNimsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the Nim Oid and the Nim Administrative Status
reading functions."
::= { sfcsBwNims 1 }
sfcsBwNimsEntry OBJECT-TYPE
SYNTAX SfcsBwNimsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains a Nim Oid and the Nim Administrative Status."
INDEX { sfcsBwNimsIndex }
::= { sfcsBwNimsTable 1 }
SfcsBwNimsEntry ::=
SEQUENCE {
sfcsBwNimsIndex INTEGER,
sfcsBwNimsAdminStatus INTEGER,
sfcsBWNimsBuffCount INTEGER,
sfcsBWNimsPortCount INTEGER,
sfcsBWNimsPrioCount INTEGER
}
-- ### Nim Defs
sfcsBwNimsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which NIM we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwNimsEntry 1 }
sfcsBwNimsAdminStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the administrative status of this Nim.
10 - Active
20 - Inactive "
::= { sfcsBwNimsEntry 2 }
sfcsBWNimsBuffCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of transmit buffers for this NIM"
::= { sfcsBwNimsEntry 3 }
sfcsBWNimsPortCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports for this NIM"
::= { sfcsBwNimsEntry 4 }
sfcsBWNimsPrioCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of priority queues for this NIM"
::= { sfcsBwNimsEntry 5 }
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Port Information
sfcsBwPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBwPortsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the Port Oid, Port Administrative Status and
the forward/reverse physical bandwidth reading functions."
::= { sfcsBwPorts 1 }
sfcsBwPortsEntry OBJECT-TYPE
SYNTAX SfcsBwPortsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the Port Oid, Port Administrative Status and
the forward/reverse physical bandwidth."
INDEX { sfcsBwPortsIndex }
::= { sfcsBwPortsTable 1 }
SfcsBwPortsEntry ::=
SEQUENCE
{
sfcsBwPortsIndex INTEGER,
sfcsBwPortsAdminStatus INTEGER,
sfcsBwPortsPhysBwFwd INTEGER,
sfcsBwPortsPhysBwRev INTEGER,
sfcsBwPortsZone INTEGER,
sfcsBwPortsMetric INTEGER
}
-- #Ports Defs
sfcsBwPortsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortsEntry 1 }
sfcsBwPortsAdminStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the administrative status of this Port.
10 - Active
20 - Inactive "
::= { sfcsBwPortsEntry 2 }
sfcsBwPortsPhysBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the forward physical bandwidth of the port in cells/sec."
::= { sfcsBwPortsEntry 3 }
sfcsBwPortsPhysBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the reverse physical bandwidth of the port in cells/sec."
::= { sfcsBwPortsEntry 4 }
sfcsBwPortsZone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The range of the current bw operational point for this port. If a value has never been set the value will be -1."
::= { sfcsBwPortsEntry 5 }
sfcsBwPortsMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current bw operational point for this port. If a value has never been set the value will be -1."
::= { sfcsBwPortsEntry 6 }
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Bandwidth Pool Limits Information
sfcsBwPortPoolLimitsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBwPortPoolLimitsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains "
::= { sfcsBwPortPools 1 }
sfcsBwPortPoolLimitsEntry OBJECT-TYPE
SYNTAX SfcsBwPortPoolLimitsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains "
INDEX { sfcsBwPortPoolLimitsIndex, sfcsBwPortPoolLimitsPoolIndex }
::= { sfcsBwPortPoolLimitsTable 1 }
SfcsBwPortPoolLimitsEntry ::=
SEQUENCE
{
sfcsBwPortPoolLimitsIndex INTEGER,
sfcsBwPortPoolLimitsPoolIndex INTEGER,
sfcsBwPortPoolLimitsMaxAllocBwFwd INTEGER,
sfcsBwPortPoolLimitsMaxAllocBwRev INTEGER,
sfcsBwPortPoolLimitsBwAllocStrat INTEGER,
sfcsBwPortPoolLimitsBwConstant INTEGER,
sfcsBwPortPoolLimitsCBRLimitFwd INTEGER,
sfcsBwPortPoolLimitsCBRLimitRev INTEGER,
sfcsBwPortPoolLimitsABRLimitFwd INTEGER,
sfcsBwPortPoolLimitsABRLimitRev INTEGER,
sfcsBwPortPoolLimitsVBRLimitFwd INTEGER,
sfcsBwPortPoolLimitsVBRLimitRev INTEGER,
sfcsBwPortPoolLimitsUBRLimitFwd INTEGER,
sfcsBwPortPoolLimitsUBRLimitRev INTEGER,
sfcsBwPortPoolLimitsUBRConnLimitFwd INTEGER,
sfcsBwPortPoolLimitsUBRConnLimitRev INTEGER
}
-- # Limit Definitions
sfcsBwPortPoolLimitsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortPoolLimitsEntry 1 }
sfcsBwPortPoolLimitsPoolIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Pool within Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortPoolLimitsEntry 2 }
sfcsBwPortPoolLimitsMaxAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Upper Limit for BW to be allocated forward direction. It is defaulted to
the physical BW and is set by administrative action. Can't be set to
a value greater than physical BW"
::= { sfcsBwPortPoolLimitsEntry 3 }
sfcsBwPortPoolLimitsMaxAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Upper Limit for BW to be allocated reverse direction. It is defaulted to
the physical BW and is set by administrative action. Can't be set to
a value greater than physical BW"
::= { sfcsBwPortPoolLimitsEntry 4 }
sfcsBwPortPoolLimitsBwAllocStrat OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Determines which of 3 sets of formulas will be used for computing
the amount of variable bandwidth to be allocated.
Conservative allocates the full amount of variable bandwidth,
Moderate allocates approximately half of the variable bandwidth,
Liberal supports very aggressive allocation and should only be
used with caution. Conservative is the default."
::= { sfcsBwPortPoolLimitsEntry 5 }
sfcsBwPortPoolLimitsBwConstant OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in formulas for computing the amount of variable
bandwidth to be allocated. Valid values are 1-255 which is the
numerator of a fraction whose fixed denominator is 256. Thus
the value 255 is really 255/256 the most conservative value;
the value 1 is really 1/256 the most liberal value; the value
128 is really 128/256 or 50%. The default is 50%."
::= { sfcsBwPortPoolLimitsEntry 6 }
sfcsBwPortPoolLimitsCBRLimitFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to CBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 7 }
sfcsBwPortPoolLimitsCBRLimitRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to CBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 8 }
sfcsBwPortPoolLimitsABRLimitFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to ABR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 9 }
sfcsBwPortPoolLimitsABRLimitRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to ABR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 10 }
sfcsBwPortPoolLimitsVBRLimitFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to VBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)
WARNING - Setting this limit to an arbitrarily low value may
cause the switch to become inoperable as an SVC switch. PNNI
establishes VBR connections for switch to switch communications.
If an arbitrarily low limit is established, it may preclude
PNNI inter-switch operability."
::= { sfcsBwPortPoolLimitsEntry 11 }
sfcsBwPortPoolLimitsVBRLimitRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to VBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)
WARNING - Setting this limit to an arbitrarily low value may
cause the switch to become inoperable as an SVC switch. PNNI
establishes VBR connections for switch to switch communications.
If an arbitrarily low limit is established, it may preclude
PNNI inter-switch operability."
::= { sfcsBwPortPoolLimitsEntry 12 }
sfcsBwPortPoolLimitsUBRLimitFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to UBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)
WARNING - Setting this limit to an arbitrarily low value may
cause the switch to become inoperable as an SVC switch. Many
internal management functions use UBR connections to establish
connections with neighboring switches for keep alive and
discovery functions.
If an arbitrarily low limit is established, it may preclude
SVC inter-switch operability."
::= { sfcsBwPortPoolLimitsEntry 13 }
sfcsBwPortPoolLimitsUBRLimitRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A ratio used in allocating the allocatable bandwidth among the
various Service classes. This value is the amount of the overall
allocatable bw that can be allocated to UBR. The values are 1-255.
For a more detailed description of value useage see
sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a
given direction should not exceed 256. (If it has never been set,
the value will be -1.)
WARNING - Setting this limit to an arbitrarily low value may
cause the switch to become inoperable as an SVC switch. Many
internal management functions use UBR connections to establish
connections with neighboring switches for keep alive and
discovery functions.
If an arbitrarily low limit is established, it may preclude
SVC inter-switch operability."
::= { sfcsBwPortPoolLimitsEntry 14 }
sfcsBwPortPoolLimitsUBRConnLimitFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A Limit to the number of UBR connections which can be established
through this port. The limit applies to both user connections and
management connections. The default is no limit. (If it has never
been set, the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 15 }
sfcsBwPortPoolLimitsUBRConnLimitRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A Limit to the number of UBR connections which can be established
through this port. The limit applies to both user connections and
management connections. The default is no limit. (If it has never
been set, the value will be -1.)"
::= { sfcsBwPortPoolLimitsEntry 16 }
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Bandwidth Pool Statistical Information
sfcsBwPortPoolStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBwPortPoolStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains "
::= { sfcsBwPortPools 2 }
sfcsBwPortPoolStatEntry OBJECT-TYPE
SYNTAX SfcsBwPortPoolStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains "
INDEX { sfcsBwPortPoolStatsIndex, sfcsBwPortPoolStatsPoolIndex }
::= { sfcsBwPortPoolStatTable 1 }
SfcsBwPortPoolStatEntry ::=
SEQUENCE
{
sfcsBwPortPoolStatsIndex INTEGER,
sfcsBwPortPoolStatsPoolIndex INTEGER,
sfcsBwPortPoolStatConnCntFwd INTEGER,
sfcsBwPortPoolStatConnCntRev INTEGER,
sfcsBwPortPoolStatAllocBwFwd INTEGER,
sfcsBwPortPoolStatAllocBwRev INTEGER,
sfcsBwPortPoolStatAvailBwFwd INTEGER,
sfcsBwPortPoolStatAvailBwRev INTEGER,
sfcsBwPortPoolStatPeakBwFwd INTEGER,
sfcsBwPortPoolStatPeakBwRev INTEGER,
sfcsBwPortPoolStatRejConnFwd INTEGER,
sfcsBwPortPoolStatRejConnRev INTEGER,
sfcsBwPortPoolStatPrevAdverMAXCRFwd INTEGER,
sfcsBwPortPoolStatPrevAdverMAXCRRev INTEGER,
sfcsBwPortPoolStatPrevAdverAvailCRFwd INTEGER,
sfcsBwPortPoolStatPrevAdverAvailCRRev INTEGER,
sfcsBwPortPoolStatCBRConnCntFwd INTEGER,
sfcsBwPortPoolStatCBRConnCntRev INTEGER,
sfcsBwPortPoolStatCBRConnRejFwd INTEGER,
sfcsBwPortPoolStatCBRConnRejRev INTEGER,
sfcsBwPortPoolStatCBRAllocBwFwd INTEGER,
sfcsBwPortPoolStatCBRAllocBwRev INTEGER,
sfcsBwPortPoolStatCBRAggPCRFwd INTEGER,
sfcsBwPortPoolStatCBRAggPCRRev INTEGER,
sfcsBwPortPoolStatCBRPrevAdverMAXCTD INTEGER,
sfcsBwPortPoolStatCBRPrevAdverCDV INTEGER,
sfcsBwPortPoolStatABRConnCntFwd INTEGER,
sfcsBwPortPoolStatABRConnCntRev INTEGER,
sfcsBwPortPoolStatABRConnRejFwd INTEGER,
sfcsBwPortPoolStatABRConnRejRev INTEGER,
sfcsBwPortPoolStatABRAllocBwFwd INTEGER,
sfcsBwPortPoolStatABRAllocBwRev INTEGER,
sfcsBwPortPoolStatABRAggPCRFwd INTEGER,
sfcsBwPortPoolStatABRAggPCRRev INTEGER,
sfcsBwPortPoolStatABRPrevAdverMAXCTD INTEGER,
sfcsBwPortPoolStatABRPrevAdverCDV INTEGER,
sfcsBwPortPoolStatVBRConnCntFwd INTEGER,
sfcsBwPortPoolStatVBRConnCntRev INTEGER,
sfcsBwPortPoolStatVBRConnRejFwd INTEGER,
sfcsBwPortPoolStatVBRConnRejRev INTEGER,
sfcsBwPortPoolStatVBRAllocBwFwd INTEGER,
sfcsBwPortPoolStatVBRAllocBwRev INTEGER,
sfcsBwPortPoolStatVBRAggPCRFwd INTEGER,
sfcsBwPortPoolStatVBRAggPCRRev INTEGER,
sfcsBwPortPoolStatVBRPrevAdverMAXCTD INTEGER,
sfcsBwPortPoolStatVBRPrevAdverCDV INTEGER,
sfcsBwPortPoolStatUBRConnCntFwd INTEGER,
sfcsBwPortPoolStatUBRConnCntRev INTEGER,
sfcsBwPortPoolStatUBRConnRejFwd INTEGER,
sfcsBwPortPoolStatUBRConnRejRev INTEGER,
sfcsBwPortPoolStatUBRAllocBwFwd INTEGER,
sfcsBwPortPoolStatUBRAllocBwRev INTEGER,
sfcsBwPortPoolStatUBRAggPCRFwd INTEGER,
sfcsBwPortPoolStatUBRAggPCRRev INTEGER,
sfcsBwPortPoolStatUBRPrevAdverMAXCTD INTEGER,
sfcsBwPortPoolStatUBRPrevAdverCDV INTEGER
}
sfcsBwPortPoolStatsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortPoolStatEntry 1 }
sfcsBwPortPoolStatsPoolIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Pool within Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortPoolStatEntry 2 }
sfcsBwPortPoolStatConnCntFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current total number of calls in the forward direction."
::= { sfcsBwPortPoolStatEntry 3 }
sfcsBwPortPoolStatConnCntRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current total number of calls in the reverse direction."
::= { sfcsBwPortPoolStatEntry 4 }
sfcsBwPortPoolStatAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current amount of allocated Bw in the forward direction."
::= { sfcsBwPortPoolStatEntry 5 }
sfcsBwPortPoolStatAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current amount of allocated Bw in the reverse direction."
::= { sfcsBwPortPoolStatEntry 6 }
sfcsBwPortPoolStatAvailBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current amount of available Bw in the forward direction."
::= { sfcsBwPortPoolStatEntry 7 }
sfcsBwPortPoolStatAvailBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The current amount of available Bw in the reverse direction."
::= { sfcsBwPortPoolStatEntry 8 }
sfcsBwPortPoolStatPeakBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The peak amount of allocated Bw in the forward direction since the
port was initialized OR the switch was reset."
::= { sfcsBwPortPoolStatEntry 9 }
sfcsBwPortPoolStatPeakBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The peak amount of allocated Bw in the reverse direction since the
port was initialized OR the switch was reset."
::= { sfcsBwPortPoolStatEntry 10 }
sfcsBwPortPoolStatRejConnFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of connections which were rejected because of
insufficient forward bandwidth since the port was initialized or
the switch was reset last."
::= { sfcsBwPortPoolStatEntry 11 }
sfcsBwPortPoolStatRejConnRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of connections which were rejected because of
insufficient reverse bandwidth since the port was initialized or
the switch was reset last."
::= { sfcsBwPortPoolStatEntry 12 }
sfcsBwPortPoolStatPrevAdverMAXCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of physical forward BW reported to PNNI in the latest
reporting period."
::= { sfcsBwPortPoolStatEntry 13 }
sfcsBwPortPoolStatPrevAdverMAXCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of physical reverse BW reported to PNNI in the latest
reporting period."
::= { sfcsBwPortPoolStatEntry 14 }
sfcsBwPortPoolStatPrevAdverAvailCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of avail forward BW reported to PNNI in the latest
reporting period."
::= { sfcsBwPortPoolStatEntry 15 }
sfcsBwPortPoolStatPrevAdverAvailCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of avail reverse BW reported to PNNI in the latest
reporting period."
::= { sfcsBwPortPoolStatEntry 16 }
-- # CBR Info
sfcsBwPortPoolStatCBRConnCntFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established CBR connections for the forward
direction."
::= { sfcsBwPortPoolStatEntry 17 }
sfcsBwPortPoolStatCBRConnCntRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established CBR connections for the reverse
direction."
::= { sfcsBwPortPoolStatEntry 18 }
sfcsBwPortPoolStatCBRConnRejFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of CBR forward connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 19 }
sfcsBwPortPoolStatCBRConnRejRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of CBR reverse connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 20 }
sfcsBwPortPoolStatCBRAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of forward allocated Bw that is CBR service class."
::= { sfcsBwPortPoolStatEntry 21 }
sfcsBwPortPoolStatCBRAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of reverse allocated Bw that is CBR service class."
::= { sfcsBwPortPoolStatEntry 22 }
sfcsBwPortPoolStatCBRAggPCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated forward PCR for all established CBR connections."
::= { sfcsBwPortPoolStatEntry 23 }
sfcsBwPortPoolStatCBRAggPCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated reverse PCR for all established CBR connections."
::= { sfcsBwPortPoolStatEntry 24 }
sfcsBwPortPoolStatCBRPrevAdverMAXCTD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The maxCTD for the forward direction reported to PNNI for the last
update period for CBR service class."
::= { sfcsBwPortPoolStatEntry 25 }
sfcsBwPortPoolStatCBRPrevAdverCDV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The CDV for the forward direction reported to PNNI for the last
update period for CBR service class."
::= { sfcsBwPortPoolStatEntry 26 }
-- # ABR Information
sfcsBwPortPoolStatABRConnCntFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established ABR connections for the forward
direction."
::= { sfcsBwPortPoolStatEntry 27 }
sfcsBwPortPoolStatABRConnCntRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established ABR connections for the reverse
direction."
::= { sfcsBwPortPoolStatEntry 28 }
sfcsBwPortPoolStatABRConnRejFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of ABR forward connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 29 }
sfcsBwPortPoolStatABRConnRejRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of ABR reverse connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 30 }
sfcsBwPortPoolStatABRAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of forward allocated Bw that is ABR service class."
::= { sfcsBwPortPoolStatEntry 31 }
sfcsBwPortPoolStatABRAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of reverse allocated Bw that is ABR service class."
::= { sfcsBwPortPoolStatEntry 32 }
sfcsBwPortPoolStatABRAggPCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated forward PCR for all established ABR connections."
::= { sfcsBwPortPoolStatEntry 33 }
sfcsBwPortPoolStatABRAggPCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated reverse PCR for all established ABR connections."
::= { sfcsBwPortPoolStatEntry 34 }
sfcsBwPortPoolStatABRPrevAdverMAXCTD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The maxCTD for the forward direction reported to PNNI for the last
update period for ABR service class."
::= { sfcsBwPortPoolStatEntry 35 }
sfcsBwPortPoolStatABRPrevAdverCDV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The CDV for the forward direction reported to PNNI for the last
update period for ABR service class."
::= { sfcsBwPortPoolStatEntry 36 }
-- # VBR Information
sfcsBwPortPoolStatVBRConnCntFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established VBR connections for the forward
direction."
::= { sfcsBwPortPoolStatEntry 37 }
sfcsBwPortPoolStatVBRConnCntRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established VBR connections for the reverse
direction."
::= { sfcsBwPortPoolStatEntry 38 }
sfcsBwPortPoolStatVBRConnRejFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of VBR forward connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 39 }
sfcsBwPortPoolStatVBRConnRejRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of VBR reverse connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 40 }
sfcsBwPortPoolStatVBRAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of forward allocated Bw that is VBR service class."
::= { sfcsBwPortPoolStatEntry 41 }
sfcsBwPortPoolStatVBRAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of reverse allocated Bw that is VBR service class."
::= { sfcsBwPortPoolStatEntry 42 }
sfcsBwPortPoolStatVBRAggPCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated forward PCR for all established VBR connections."
::= { sfcsBwPortPoolStatEntry 43 }
sfcsBwPortPoolStatVBRAggPCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated reverse PCR for all established VBR connections."
::= { sfcsBwPortPoolStatEntry 44 }
sfcsBwPortPoolStatVBRPrevAdverMAXCTD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The maxCTD for the forward direction reported to PNNI for the last
update period for VBR service class."
::= { sfcsBwPortPoolStatEntry 45 }
sfcsBwPortPoolStatVBRPrevAdverCDV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The CDV for the forward direction reported to PNNI for the last
update period for VBR service class."
::= { sfcsBwPortPoolStatEntry 46 }
-- # UBR Information
sfcsBwPortPoolStatUBRConnCntFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established UBR connections for the forward
direction."
::= { sfcsBwPortPoolStatEntry 47 }
sfcsBwPortPoolStatUBRConnCntRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of currently established UBR connections for the reverse
direction."
::= { sfcsBwPortPoolStatEntry 48 }
sfcsBwPortPoolStatUBRConnRejFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of UBR forward connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 49 }
sfcsBwPortPoolStatUBRConnRejRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of UBR reverse connections rejected since the port was
initialized or the switch was reset last."
::= { sfcsBwPortPoolStatEntry 50 }
sfcsBwPortPoolStatUBRAllocBwFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of forward allocated Bw that is UBR service class."
::= { sfcsBwPortPoolStatEntry 51 }
sfcsBwPortPoolStatUBRAllocBwRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The amount of reverse allocated Bw that is UBR service class."
::= { sfcsBwPortPoolStatEntry 52 }
sfcsBwPortPoolStatUBRAggPCRFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated forward PCR for all established UBR connections."
::= { sfcsBwPortPoolStatEntry 53 }
sfcsBwPortPoolStatUBRAggPCRRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The aggregated reverse PCR for all established UBR connections."
::= { sfcsBwPortPoolStatEntry 54 }
sfcsBwPortPoolStatUBRPrevAdverMAXCTD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The maxCTD for the forward direction reported to PNNI for the last
update period for UBR service class."
::= { sfcsBwPortPoolStatEntry 55 }
sfcsBwPortPoolStatUBRPrevAdverCDV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The CDV for the forward direction reported to PNNI for the last
update period for UBR service class."
::= { sfcsBwPortPoolStatEntry 56 }
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Bandwidth Pool Trap Management Information
sfcsBwPortPoolTrapMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBwPortPoolTrapMgmtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains "
::= { sfcsBwPortPools 3 }
sfcsBwPortPoolTrapMgmtEntry OBJECT-TYPE
SYNTAX SfcsBwPortPoolTrapMgmtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains "
INDEX { sfcsBwPortPoolTrapMgmtIndex, sfcsBwPortPoolTrapMgmtPoolIndex }
::= { sfcsBwPortPoolTrapMgmtTable 1 }
SfcsBwPortPoolTrapMgmtEntry ::=
SEQUENCE
{
sfcsBwPortPoolTrapMgmtIndex INTEGER,
sfcsBwPortPoolTrapMgmtPoolIndex INTEGER,
sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtPeakBwTholdFwd INTEGER,
sfcsBwPortPoolTrapMgmtPeakBwTholdRev INTEGER,
sfcsBwPortPoolTrapMgmtHoldDownTime INTEGER,
sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev INTEGER,
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd INTEGER,
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev INTEGER,
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd INTEGER,
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev INTEGER,
sfcsBWPortPoolTrapMgmtBuffUpThold INTEGER,
sfcsBWPortPoolTrapMgmtBuffLoThold INTEGER,
sfcsBWPortPoolTrapMgmtConnRejThold INTEGER
}
sfcsBwPortPoolTrapMgmtIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBwPortPoolTrapMgmtEntry 1 }
sfcsBwPortPoolTrapMgmtPoolIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which Pool within Port we are dealing
with. This reference is in the same format as MIB II's
Interface index. (If it has never been set, the value will
be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 2 }
sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The upper threshold for the Alloc BW fwd trap. When an allocation
causes the currently allocated bw to exceed this value the trap
is generated. (If it has never been set, the value will
be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 3 }
sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the Alloc BW rev trap. When an allocation
causes the currently allocated bw to exceed this value the trap
is generated. (If it has never been set, the value will
be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 4 }
sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the Alloc BW fwd trap. When an allocation
causes the currently allocated bw be below this value the trap
is generated. (If it has never been set, the value will
be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 5 }
sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the Alloc BW rev trap. When an allocation
causes the currently allocated bw be below this value the trap
is generated. (If it has never been set, the value will
be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 6 }
sfcsBwPortPoolTrapMgmtPeakBwTholdFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The upper threshold for the Peak BW fwd trap. When an allocation
causes the allocated BW to exceed this value the trap is generated.
(If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 7 }
sfcsBwPortPoolTrapMgmtPeakBwTholdRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The upper threshold for the Peak BW rev trap. When an allocation
causes the allocated BW to exceed this value the trap is generated.
(If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 8 }
sfcsBwPortPoolTrapMgmtHoldDownTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The time between traps of the same type. If a trap of a particular
type is generated for a particular port, another of that type for that
port will not be generated until the hold down time has expired.
(If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 9 }
-- # CBR Information
sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the CBR connection count Fwd trap. When an
allocation causes the CBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 10 }
sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the CBR connection count Rev trap. When an
allocation causes the CBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 11 }
sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the CBR connection count Fwd trap. When an
allocation causes the CBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 12 }
sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the CBR connection count Rev trap. When an
allocation causes the CBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 13 }
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the CBR Allocated Bw Fwd trap. When an
allocation causes the CBR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 14 }
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the CBR connection count Rev trap. When an
allocation causes the CBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 15 }
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the CBR Allocated Bw Fwd trap. When an
allocation causes the CBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 16 }
sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the CBR Allocated Bw Rev trap. When an
allocation causes the CBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 17 }
-- # ABR Information
sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the ABR connection count Fwd trap. When an
allocation causes the ABR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 18 }
sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the ABR connection count Rev trap. When an
allocation causes the ABR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 19 }
sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the ABR connection count Fwd trap. When an
allocation causes the ABR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 20 }
sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the ABR connection count Rev trap. When an
allocation causes the ABR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 21 }
sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the ABR Allocated Bw Fwd trap. When an
allocation causes the ABR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 22 }
sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the ABR Allocated Bw Rev trap. When an
allocation causes the ABR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 23 }
sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the ABR Allocated Bw Fwd trap. When an
allocation causes the ABR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 24 }
sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the ABR Allocated Bw Rev trap. When an
allocation causes the ABR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 25 }
-- # VBR Information
sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the VBR connection count Fwd trap. When an
allocation causes the VBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 26 }
sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the VBR connection count Rev trap. When an
allocation causes the VBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 27 }
sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the VBR connection count Fwd trap. When an
allocation causes the VBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 28 }
sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the VBR connection count Rev trap. When an
allocation causes the VBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 29 }
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the VBR Allocated Bw Fwd trap. When an
allocation causes the VBR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 30 }
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the VBR Allocated Bw Rev trap. When an
allocation causes the VBR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 31 }
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the VBR Allocated Bw Fwd trap. When an
allocation causes the VBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 32 }
sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the VBR Allocated Bw Rev trap. When an
allocation causes the VBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 33 }
-- # UBR Information
sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the UBR connection count Fwd trap. When an
allocation causes the UBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 34 }
sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the UBR connection count Rev trap. When an
allocation causes the UBR connection count to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 35 }
sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the UBR connection count Fwd trap. When an
allocation causes the UBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 36 }
sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the UBR connection count Rev trap. When an
allocation causes the UBR connection count to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 37 }
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the UBR Allocated Bw Fwd trap. When an
allocation causes the UBR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 38 }
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for the UBR Allocated Bw Rev trap. When an
allocation causes the UBR Allocated Bw to exceed this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 39 }
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the UBR Allocated Bw Fwd trap. When an
allocation causes the UBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 40 }
sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for the UBR Allocated Bw Rev trap. When an
allocation causes the UBR Allocated Bw to fall below this value,
the trap is generated. (If it has never been set, the value will be -1.)"
::= { sfcsBwPortPoolTrapMgmtEntry 41 }
sfcsBWPortPoolTrapMgmtBuffUpThold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold for buffer allocation trap ."
::= { sfcsBwPortPoolTrapMgmtEntry 42 }
sfcsBWPortPoolTrapMgmtBuffLoThold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for buffer allocation trap ."
::= { sfcsBwPortPoolTrapMgmtEntry 43 }
sfcsBWPortPoolTrapMgmtConnRejThold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold for conn rejects trap ."
::= { sfcsBwPortPoolTrapMgmtEntry 44 }
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- ### Buffer Pool Information
-- Each Buffer Pool consists of a number of rows- one for each priority
-- The primary index is the ifindex of the port that owns these row entries
-- The secondary index is the priority number for the row
--
sfcsBuffPrioTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsBuffPrioEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the rows of all the buffer pools."
::= { sfcsBuffPools 1 }
sfcsBuffPrioEntry OBJECT-TYPE
SYNTAX SfcsBuffPrioEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the rows of all the buffer pools."
INDEX { sfcsBuffPrioPortIndex, sfcsBuffPrioPriority }
::= { sfcsBuffPrioTable 1 }
SfcsBuffPrioEntry ::=
SEQUENCE {
sfcsBuffPrioPortIndex INTEGER,
sfcsBuffPrioPriority INTEGER,
sfcsBuffPrioAssignCtl INTEGER,
sfcsBuffPrioMinCtl INTEGER,
sfcsBuffPrioAssigned INTEGER,
sfcsBuffPrioAllocated INTEGER,
sfcsBuffPrioAvailable INTEGER,
sfcsBuffPrioPeakAlloc INTEGER,
sfcsBuffPrioConnRejs INTEGER,
sfcsBuffPrioUpTholdTrap INTEGER,
sfcsBuffPrioLoTholdTrap INTEGER,
sfcsBuffPrioConnRejThold INTEGER
}
-- ### Entry Defs
sfcsBuffPrioPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which port we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsBuffPrioEntry 1 }
sfcsBuffPrioPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which priority we are dealing
with."
::= { sfcsBuffPrioEntry 2 }
sfcsBuffPrioAssignCtl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The status of how assignment is controlled. Static,Manual,Adaptive. "
::= { sfcsBuffPrioEntry 3}
sfcsBuffPrioMinCtl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The minimum number of cells which can be assigned to this
port/prioity."
::= { sfcsBuffPrioEntry 4}
sfcsBuffPrioAssigned OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The number of cells which are currently assigned to this
port/priority."
::= { sfcsBuffPrioEntry 5}
sfcsBuffPrioAllocated OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of assigned cells which are currently allocated to
VCs for this port/priority."
::= { sfcsBuffPrioEntry 6}
sfcsBuffPrioAvailable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of assigned cells which are free to be allocated."
::= { sfcsBuffPrioEntry 7}
sfcsBuffPrioPeakAlloc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The peak number of cells which have been allocated to this
port/priority."
::= { sfcsBuffPrioEntry 8}
sfcsBuffPrioConnRejs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The number of connections rejected because of a lack of buffers."
::= { sfcsBuffPrioEntry 9}
sfcsBuffPrioUpTholdTrap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The upper threshold of allocations to trigger an upper thold trap."
::= { sfcsBuffPrioEntry 10}
sfcsBuffPrioLoTholdTrap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold of allocations to trigger a lower thold trap."
::= { sfcsBuffPrioEntry 11}
sfcsBuffPrioConnRejThold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The lower threshold of conn rejects trap because of inadequate buffers."
::= { sfcsBuffPrioEntry 12}
-- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-- The SFCS ANIM Proxy Group
-- SFCS ANIM Proxy Group
-- This group contains the managed objects and functions used to setup and
-- configure the SFCS ANIM Proxies. This group contains three sub-groups:
-- configuration status, Transmit function setup, and Port Read
-- SFCS ANIM Proxy Configuration Status Table
-- This table contains contains information about the status of the Port or Proxy
-- as a whole, as opposed to the receive and Transmit table which contain information
-- about cells.
sfcsProxyConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsProxyConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the config info and a port
reading function."
::= { sfcsProxyConfig 1 }
sfcsProxyConfigEntry OBJECT-TYPE
SYNTAX SfcsProxyConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains ANIM Proxy config info or a function."
INDEX { sfcsProxyConfigANIMIndex }
::= { sfcsProxyConfigTable 1 }
SfcsProxyConfigEntry ::=
SEQUENCE {
sfcsProxyConfigANIMIndex INTEGER,
sfcsProxyConfigNUMPORTS INTEGER,
sfcsProxyConfigTxMemSize INTEGER,
sfcsProxyConfigRxMaxPduSize INTEGER,
sfcsProxyConfigBandWidth INTEGER,
sfcsProxyConfigTransmitDone INTEGER,
sfcsProxyConfigReceiveFifoState INTEGER,
sfcsProxyConfigPortTransmitMode INTEGER,
sfcsProxyConfigReceiveFifoReset INTEGER,
sfcsProxyConfigTxFifoReset INTEGER,
sfcsProxyConfigReceiveMode INTEGER,
sfcsProxyConfigCaptureMode INTEGER,
sfcsProxyConfigInitPort INTEGER,
sfcsProxyConfigLoad INTEGER,
sfcsProxyConfigGumbo OCTET STRING
}
sfcsProxyConfigANIMIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which ANIM Proxy we are dealing
with. This reference is in the same format as MIB II's
Interface index."
::= { sfcsProxyConfigEntry 1 }
sfcsProxyConfigNUMPORTS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of ports per Proxy which is always 4."
::= { sfcsProxyConfigEntry 2 }
sfcsProxyConfigTxMemSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the size of the port's Transmission memory in K.
The memory size is always 1K."
::= { sfcsProxyConfigEntry 3 }
sfcsProxyConfigRxMaxPduSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the size of the port's Transmission memory in K.
The memory size is always 1K."
::= { sfcsProxyConfigEntry 4 }
sfcsProxyConfigBandWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the bandwidth for the port, which is ?????"
::= { sfcsProxyConfigEntry 5 }
sfcsProxyConfigTransmitDone OBJECT-TYPE
SYNTAX INTEGER {
yes (1),
no (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Checks if the Transmission has finished."
::= { sfcsProxyConfigEntry 6 }
sfcsProxyConfigReceiveFifoState OBJECT-TYPE
SYNTAX INTEGER {
full(1),
not-full(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Checks if the port's receive Fifo is full or not."
::= { sfcsProxyConfigEntry 7 }
sfcsProxyConfigPortTransmitMode OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
start-stay(2),
reread(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls Transmission of cells in port Transmit memory."
::= { sfcsProxyConfigEntry 8 }
sfcsProxyConfigReceiveFifoReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Controls the receive buffer's memory. Reset clears memory."
::= { sfcsProxyConfigEntry 9 }
sfcsProxyConfigTxFifoReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Controls the port's transmit memory. Reset clears memory."
::= { sfcsProxyConfigEntry 10 }
sfcsProxyConfigReceiveMode OBJECT-TYPE
SYNTAX INTEGER {
receiving (1),
not-receiving (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether or not the port receives cells."
::= { sfcsProxyConfigEntry 11 }
sfcsProxyConfigCaptureMode OBJECT-TYPE
SYNTAX INTEGER {
all (1),
header (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls how much of the cell is received."
::= { sfcsProxyConfigEntry 12 }
sfcsProxyConfigInitPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this returns the port to the initial setup."
::= { sfcsProxyConfigEntry 13 }
sfcsProxyConfigLoad OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transmit load for port."
::= { sfcsProxyConfigEntry 14 }
sfcsProxyConfigGumbo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unreadable octet string used for control information."
::= { sfcsProxyConfigEntry 15 }
-- SFCS ANIM Proxy Transmit function setup Table.
-- This table contains the function to send cells from specific ports and
-- the arguments which this function takes.
sfcsProxyTransTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsProxyTransEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the arguments and the function for the
Transmit function."
::= { sfcsProxyTrans 1 }
sfcsProxyTransEntry OBJECT-TYPE
SYNTAX SfcsProxyTransEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entries are the arguments for the Transmit function."
INDEX { sfcsProxyTransANIMIndex }
::= { sfcsProxyTransTable 1 }
SfcsProxyTransEntry ::=
SEQUENCE {
sfcsProxyTransANIMIndex INTEGER,
sfcsProxyTransEncodeNewPdu INTEGER,
sfcsProxyTransVPI INTEGER,
sfcsProxyTransVCI INTEGER,
sfcsProxyTransPTI INTEGER,
sfcsProxyTransCLP INTEGER,
sfcsProxyTransPayloadType INTEGER,
sfcsProxyTransPayloadLength INTEGER,
sfcsProxyTransPayloadData OCTET STRING,
sfcsProxyTransCount INTEGER,
sfcsProxyTransPayloadAdaptionLayer INTEGER,
sfcsProxyTransMpxMethod INTEGER,
sfcsProxyTransControl INTEGER,
sfcsProxyTransGumbo OCTET STRING
}
sfcsProxyTransANIMIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which ANIM Port we are dealing
with. This reference is in the same format as MIB II's
Interface Index."
::= { sfcsProxyTransEntry 1 }
sfcsProxyTransEncodeNewPdu OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this encodes a new PDU based on the current PDU parameters
into the port's transmit memory."
::= { sfcsProxyTransEntry 2 }
sfcsProxyTransVPI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the VPI for the PDU."
::= { sfcsProxyTransEntry 3 }
sfcsProxyTransVCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the VCI for the PDU."
::= { sfcsProxyTransEntry 4 }
sfcsProxyTransPTI OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Payload Type Indicator: the value of the 3 bit Payload Type
field in the header. The most signifigant bit indicates user or
control data, the next bit indicates congestion, and the
last bit indicates AAL encoding."
::= { sfcsProxyTransEntry 5 }
sfcsProxyTransCLP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The cell loss priority: 1 or 0."
::= { sfcsProxyTransEntry 6 }
sfcsProxyTransPayloadType OBJECT-TYPE
SYNTAX INTEGER {
user-input(1),
sequential(2),
uniform(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The payload type for the cell."
::= { sfcsProxyTransEntry 7 }
sfcsProxyTransPayloadLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The length of the payload in bytes."
::= { sfcsProxyTransEntry 8 }
sfcsProxyTransPayloadData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the payload type is user input, this is the payload itself."
::= { sfcsProxyTransEntry 9 }
sfcsProxyTransCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of copies of the pdu to encode in port transmit memory."
::= { sfcsProxyTransEntry 10 }
sfcsProxyTransPayloadAdaptionLayer OBJECT-TYPE
SYNTAX INTEGER {
raw(1),
aal5(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The format of the payload: either raw cells or AAL5."
::= { sfcsProxyTransEntry 11 }
sfcsProxyTransMpxMethod OBJECT-TYPE
SYNTAX INTEGER
--{
-- enumerate me!!
-- }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The format of the payload: either raw cells or AAL5."
::= { sfcsProxyTransEntry 12 }
sfcsProxyTransControl OBJECT-TYPE
SYNTAX INTEGER {
send-once(1),
repeat(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls how many times to send what's in the port's
transmit memory."
::= { sfcsProxyTransEntry 13 }
sfcsProxyTransGumbo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns the vpi, vci, pti, clp, payload_type, payload_length, count,
PAL, mpx method, and control entires for this table in a string where
the entries are separated by semicolons."
::= { sfcsProxyTransEntry 14 }
-- SFCS ANIM Port Read
-- This table contains the information read from cells from a port's receive fifo.
sfcsProxyReadTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfcsProxyReadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information read from the cells in the receive fifo."
::= { sfcsProxyRead 1 }
sfcsProxyReadEntry OBJECT-TYPE
SYNTAX SfcsProxyReadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entries are the information about the cells or the PDU."
INDEX { sfcsProxyReadANIMIndex }
::= { sfcsProxyReadTable 1 }
SfcsProxyReadEntry ::=
SEQUENCE {
sfcsProxyReadANIMIndex INTEGER,
sfcsProxyReadMode INTEGER,
sfcsProxyReadNewPdu INTEGER,
sfcsProxyReadGumbo OCTET STRING,
sfcsProxyReadVPI INTEGER,
sfcsProxyReadVCI INTEGER,
sfcsProxyReadPTI INTEGER,
sfcsProxyReadCLP INTEGER,
sfcsProxyReadDataLength INTEGER,
sfcsProxyReadData OCTET STRING,
sfcsProxyReadPal INTEGER,
sfcsProxyReadInbyteslosts INTEGER,
sfcsProxyReadInCells INTEGER,
sfcsProxyReadInError INTEGER,
sfcsProxyReadInCellReadError INTEGER,
sfcsProxyReadInHecError INTEGER,
sfcsProxyReadInTooBigError INTEGER,
sfcsProxyReadInCRCError INTEGER,
sfcsProxyReadInLengthMismatchError INTEGER,
sfcsProxyReadInTotalCells INTEGER
}
sfcsProxyReadANIMIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This index specifies which ANIM Port we are dealing
with. This reference is in the same format as the MIB II
Interface Index."
::= { sfcsProxyReadEntry 1 }
sfcsProxyReadMode OBJECT-TYPE
SYNTAX INTEGER {
reassemble-PDU(1),
cell-by-cell(2),
all-data(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"How the receive fifo is read."
::= { sfcsProxyReadEntry 2 }
sfcsProxyReadNewPdu OBJECT-TYPE
SYNTAX INTEGER {
get-next-pdu(1),
reread-from-beginning(2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Pops a new Pdu from the receive fifo to be examined and read."
::= { sfcsProxyReadEntry 3 }
sfcsProxyReadGumbo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Unreadable control information."
::= { sfcsProxyReadEntry 4 }
sfcsProxyReadVPI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the VPI for the PDU."
::= { sfcsProxyReadEntry 5 }
sfcsProxyReadVCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the VCI for the PDU."
::= { sfcsProxyReadEntry 6 }
sfcsProxyReadPTI OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Payload Type Indicator: the value of the 3 bit Payload Type
field in the header. The most signifigant bit indicates user or
control data, the next bit indicates congestion, and the
last bit indicates AAL encoding."
::= { sfcsProxyReadEntry 7 }
sfcsProxyReadCLP OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cell loss priority: 1 or 0."
::= { sfcsProxyReadEntry 8 }
sfcsProxyReadDataLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The length of the PDU in bytes."
::= { sfcsProxyReadEntry 9 }
sfcsProxyReadData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The actual data of the PDU."
::= { sfcsProxyReadEntry 10 }
sfcsProxyReadPal OBJECT-TYPE
SYNTAX INTEGER {
raw(1),
aal5(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The format of the payload: either raw cells or AAL5."
::= { sfcsProxyReadEntry 11 }
sfcsProxyReadInbyteslosts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes that were dropped while reading. Usually because
they occurred before the Start of Cell was discovered."
::= { sfcsProxyReadEntry 12 }
sfcsProxyReadInCells OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells read since this port was last reset."
::= { sfcsProxyReadEntry 13 }
sfcsProxyReadInError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of pdu's that had to be dropped due to errors."
::= { sfcsProxyReadEntry 14 }
sfcsProxyReadInCellReadError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cells that had to be dropped due to errors."
::= { sfcsProxyReadEntry 15 }
sfcsProxyReadInHecError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cell headers that contained errors."
::= { sfcsProxyReadEntry 16 }
sfcsProxyReadInTooBigError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of pdu's that were too large to be received."
::= { sfcsProxyReadEntry 17 }
sfcsProxyReadInCRCError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of pdu's that failed the CRC check."
::= { sfcsProxyReadEntry 18 }
sfcsProxyReadInLengthMismatchError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The length stored in the pdu did not match the actual
length of the pdu read in."
::= { sfcsProxyReadEntry 19 }
sfcsProxyReadInTotalCells OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of cells read in by the snapshot."
::= { sfcsProxyReadEntry 20 }
END