CTRON-SFPS-L4SS-MIB DEFINITIONS ::= BEGIN
-- sfps-l4ss.mib
-- Revision: 0.0.06
-- Date: June 25, 1999
--
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for the
-- Layer 4 Smart Switch (L4SS).
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright October 93 Cabletron Systems
--
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString, PhysAddress
FROM RFC1213-MIB
IpAddress, Counter, TimeTicks
FROM RFC1155-SMI
-- These Objects are defined in the file sfps-inc.mib.txt
switchSFPS
FROM CTRON-SFPS-INCLUDE-MIB;
-- New SFPS Switch Group.
sfpsL4SS OBJECT IDENTIFIER ::= { switchSFPS 6 }
-- The SFPS Layer 4 SmartSwitch Groups.
sfpsL4CP OBJECT IDENTIFIER ::= { sfpsL4SS 1 }
sfpsL4CDR OBJECT IDENTIFIER ::= { sfpsL4SS 2 }
l4cpStats OBJECT IDENTIFIER ::= { sfpsL4CP 1 }
l4cpConfig OBJECT IDENTIFIER ::= { sfpsL4CP 2 }
l4cpActions OBJECT IDENTIFIER ::= { sfpsL4CP 3 }
l4cdrStats OBJECT IDENTIFIER ::= { sfpsL4CDR 1 }
l4cdrConfig OBJECT IDENTIFIER ::= { sfpsL4CDR 2 }
l4cdrActions OBJECT IDENTIFIER ::= { sfpsL4CDR 3 }
-- Textual Conventions
HexInteger ::= INTEGER
-- display this integer in hex format
SfpsAddress ::= OCTET STRING (SIZE (6))
-- this will map to a MAC address
-- SFPS L4CP Scalars
sfpsL4CPDisableTCPAckCheck OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates whether or not TCP
segments whose ACK bit is off are allowed to use an
existing flow table entry. When set to 2, a TCP
segment whose ACK bit is off is always treated as an
exception packet. This variable takes effect immediately,
and its value is peristent."
::= { l4cpConfig 1 }
-- SFPS FLOW TABLE
sfpsL4CPFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes each conversation between a pair
or Layer 3 or Layer 4 endpoints."
::= { sfpsL4CP 4 }
sfpsL4CPFlowEntry OBJECT-TYPE
SYNTAX SfpsL4CPFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains statistics and information for
a pair of Layer 3 or Layer 4 endpoints."
INDEX { sfpsL4CPFlowCnxIndex,
sfpsL4CPFlowSecL3Address,
sfpsL4CPFlowPrimL3Address,
sfpsL4CPFlowSubprotocol,
sfpsL4CPFlowSecMatchAnyDyn,
sfpsL4CPFlowPrimMatchAnyDyn,
sfpsL4CPFlowSecProtPort,
sfpsL4CPFlowPrimProtPort }
::= { sfpsL4CPFlowTable 1 }
SfpsL4CPFlowEntry ::=
SEQUENCE {
sfpsL4CPFlowCnxIndex INTEGER,
sfpsL4CPFlowSecL3Address DisplayString,
sfpsL4CPFlowPrimL3Address DisplayString,
sfpsL4CPFlowSubprotocol HexInteger,
sfpsL4CPFlowSecMatchAnyDyn INTEGER,
sfpsL4CPFlowPrimMatchAnyDyn INTEGER,
sfpsL4CPFlowSecProtPort INTEGER,
sfpsL4CPFlowPrimProtPort INTEGER,
sfpsL4CPFlowSecSubstApplies INTEGER,
sfpsL4CPFlowPrimSubstApplies INTEGER,
sfpsL4CPFlowSecInPkts Counter,
sfpsL4CPFlowSecInOctets Counter,
sfpsL4CPFlowPrimInPkts Counter,
sfpsL4CPFlowPrimInOctets Counter,
sfpsL4CPFlowFlowAge TimeTicks,
sfpsL4CPFlowFlowLastUse TimeTicks,
sfpsL4CPFlowID INTEGER
}
sfpsL4CPFlowCnxIndex OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index (1-based) of the SFPSGAPI connection table entry
to which this flow belongs."
::= { sfpsL4CPFlowEntry 1 }
sfpsL4CPFlowSecL3Address OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address of the secondary endpoint for this flow.
The secondary endpoint is the one having the higher MAC address."
::= { sfpsL4CPFlowEntry 2 }
sfpsL4CPFlowPrimL3Address OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address of the primary endpoint for this flow.
The primary endpoint is the one having the lower MAC address."
::= { sfpsL4CPFlowEntry 3 }
sfpsL4CPFlowSubprotocol OBJECT-TYPE
SYNTAX HexInteger(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value identifies the Layer 4 protocol. It
corresponds to the IP 'Protocol' field as described
in the 'Assigned Numbers' RFC."
::= { sfpsL4CPFlowEntry 4 }
sfpsL4CPFlowSecMatchAnyDyn OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a TCP or UDP entry, this value specifies whether
or not the protocol port of the secondary endpoint should
be treated as a wildcard, able to match any port number above
1023."
::= { sfpsL4CPFlowEntry 5 }
sfpsL4CPFlowPrimMatchAnyDyn OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a TCP or UDP entry, this value specifies whether
or not the protocol port of the primary endpoint should
be treated as a wildcard, able to match any port number above
1023."
::= { sfpsL4CPFlowEntry 6 }
sfpsL4CPFlowSecProtPort OBJECT-TYPE
SYNTAX INTEGER(0..'FFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a TCP or UDP entry, this value indicates the
protocol port number of the secondary endpoint.
Otherwise, this field is zero."
::= { sfpsL4CPFlowEntry 7 }
sfpsL4CPFlowPrimProtPort OBJECT-TYPE
SYNTAX INTEGER(0..'FFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a TCP or UDP entry, this value indicates the
protocol port number of the primary endpoint.
Otherwise, this field is zero."
::= { sfpsL4CPFlowEntry 8 }
sfpsL4CPFlowSecSubstApplies OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication of whether or not MAC address substitution
applies to the secondary endpoint for this flow."
::= { sfpsL4CPFlowEntry 9 }
sfpsL4CPFlowPrimSubstApplies OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication of whether or not MAC address substitution
applies to the primary endpoint for this flow."
::= { sfpsL4CPFlowEntry 10 }
sfpsL4CPFlowSecInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of packets transmitted from primary to secondary."
::= { sfpsL4CPFlowEntry 11 }
sfpsL4CPFlowSecInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of octets transmitted from primary to secondary."
::= { sfpsL4CPFlowEntry 12 }
sfpsL4CPFlowPrimInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of packets transmitted from secondary to primary."
::= { sfpsL4CPFlowEntry 13 }
sfpsL4CPFlowPrimInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of octets transmitted from secondary to primary."
::= { sfpsL4CPFlowEntry 14 }
sfpsL4CPFlowFlowAge OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time elapsed since this entry was created."
::= { sfpsL4CPFlowEntry 15 }
sfpsL4CPFlowFlowLastUse OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time elapsed since this entry was last used to send data."
::= { sfpsL4CPFlowEntry 16 }
sfpsL4CPFlowID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Call Detail Recording flow ID for this flow, or zero
if CDR is not active for the flow."
::= { sfpsL4CPFlowEntry 17 }
-- SFPS MAC ADDRESS SUBSTITUTION TABLE
sfpsL4CPMACAddrSubTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPMACAddrSubEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table provides the ability to override the default
gateway for specific routes."
::= { sfpsL4CP 5 }
sfpsL4CPMACAddrSubEntry OBJECT-TYPE
SYNTAX SfpsL4CPMACAddrSubEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the MAC address substitution information
associated with a specific destination IP address."
INDEX { sfpsL4CPMACAddrSubDestIP }
::= { sfpsL4CPMACAddrSubTable 1 }
SfpsL4CPMACAddrSubEntry ::=
SEQUENCE {
sfpsL4CPMACAddrSubDestIP IpAddress,
sfpsL4CPMACAddrSubNextHopMAC PhysAddress,
sfpsL4CPMACAddrSubRefCount INTEGER
}
sfpsL4CPMACAddrSubDestIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP address for this route"
::= { sfpsL4CPMACAddrSubEntry 1 }
sfpsL4CPMACAddrSubNextHopMAC OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The next-hop MAC address to use for this route."
::= { sfpsL4CPMACAddrSubEntry 2 }
sfpsL4CPMACAddrSubRefCount OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of flow table entries that reference this entry."
::= { sfpsL4CPMACAddrSubEntry 3 }
-- SFPS NETWORK ADDRESS SUBSTITUTION TABLE
sfpsL4CPNetAddrUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPNetAddrUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table associates user information with network
addresses."
::= { sfpsL4CP 7 }
sfpsL4CPNetAddrUserEntry OBJECT-TYPE
SYNTAX SfpsL4CPNetAddrUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the user information
associated with a specific network address."
INDEX { sfpsL4CPNetAddrUserProtocol,
sfpsL4CPNetAddrUserNetAddr }
::= { sfpsL4CPNetAddrUserTable 1 }
SfpsL4CPNetAddrUserEntry ::=
SEQUENCE {
sfpsL4CPNetAddrUserProtocol INTEGER,
sfpsL4CPNetAddrUserNetAddr DisplayString,
sfpsL4CPNetAddrUserLoginID INTEGER,
sfpsL4CPNetAddrUserUserID INTEGER,
sfpsL4CPNetAddrUserUserName DisplayString
}
sfpsL4CPNetAddrUserProtocol OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network-layer protocol associated with this entry. Values
correspond to the 'aoAddressTag' enumeration
(see aoproperties.h)."
::= { sfpsL4CPNetAddrUserEntry 1 }
sfpsL4CPNetAddrUserNetAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network-layer address associated with this entry."
::= { sfpsL4CPNetAddrUserEntry 2 }
sfpsL4CPNetAddrUserLoginID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The login ID from CSM's LoginOID. Set to zero
if no user is logged into the address."
::= { sfpsL4CPNetAddrUserEntry 3 }
sfpsL4CPNetAddrUserUserID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The object ID from CSM's UserOID."
::= { sfpsL4CPNetAddrUserEntry 4 }
sfpsL4CPNetAddrUserUserName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name associated with this entry."
::= { sfpsL4CPNetAddrUserEntry 5 }
-- SFPS IP ROUTE TABLE
sfpsL4CPIPRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPIPRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table associates IP routes (subnets) with devices."
::= { sfpsL4CP 8 }
sfpsL4CPIPRouteEntry OBJECT-TYPE
SYNTAX SfpsL4CPIPRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the IP route information
associated with a specific device."
INDEX { sfpsL4CPIPRouteSubnetMask,
sfpsL4CPIPRouteSubnet }
::= { sfpsL4CPIPRouteTable 1 }
SfpsL4CPIPRouteEntry ::=
SEQUENCE {
sfpsL4CPIPRouteSubnetMask IpAddress,
sfpsL4CPIPRouteSubnet IpAddress,
sfpsL4CPIPRouteRouteID INTEGER,
sfpsL4CPIPRouteRouteSubsystem INTEGER,
sfpsL4CPIPRouteDeviceID INTEGER,
sfpsL4CPIPRouteDeviceName DisplayString,
sfpsL4CPIPRouteMACAddress SfpsAddress,
sfpsL4CPIPRouteMetric INTEGER,
sfpsL4CPIPRouteCallable INTEGER
}
sfpsL4CPIPRouteSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The subnet mask associated with this route."
::= { sfpsL4CPIPRouteEntry 1 }
sfpsL4CPIPRouteSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The destination subnet of this route."
::= { sfpsL4CPIPRouteEntry 2 }
sfpsL4CPIPRouteRouteID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The object ID from CSM's RouteOID."
::= { sfpsL4CPIPRouteEntry 3 }
sfpsL4CPIPRouteRouteSubsystem OBJECT-TYPE
SYNTAX INTEGER { local(1),
remote(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates type of device route."
::= { sfpsL4CPIPRouteEntry 4 }
sfpsL4CPIPRouteDeviceID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The object ID from CSM's DeviceOID."
::= { sfpsL4CPIPRouteEntry 5 }
sfpsL4CPIPRouteDeviceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device name for this route."
::= { sfpsL4CPIPRouteEntry 6 }
sfpsL4CPIPRouteMACAddress OBJECT-TYPE
SYNTAX SfpsAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of the device for this route."
::= { sfpsL4CPIPRouteEntry 7 }
sfpsL4CPIPRouteMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The metric associated with this route."
::= { sfpsL4CPIPRouteEntry 8 }
sfpsL4CPIPRouteCallable OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not the device associated
with this route is callable for IP."
::= { sfpsL4CPIPRouteEntry 9 }
-- SFPS PORT TABLE
sfpsL4CPPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the attributes of an access servers ports."
::= { sfpsL4CP 9 }
sfpsL4CPPortEntry OBJECT-TYPE
SYNTAX SfpsL4CPPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information about
one of this access server's ports."
INDEX { sfpsL4CPPortNum }
::= { sfpsL4CPPortTable 1 }
SfpsL4CPPortEntry ::=
SEQUENCE {
sfpsL4CPPortNum INTEGER,
sfpsL4CPPortID INTEGER,
sfpsL4CPPortApplyPolicyIn INTEGER,
sfpsL4CPPortApplyPolicyOut INTEGER,
sfpsL4CPPortDefaultUserID INTEGER,
sfpsL4CPPortDefaultUserName DisplayString
}
sfpsL4CPPortNum OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The logical port number of this port."
::= { sfpsL4CPPortEntry 1 }
sfpsL4CPPortID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last four octets of CSM's PortOID for this port."
::= { sfpsL4CPPortEntry 2 }
sfpsL4CPPortApplyPolicyIn OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not access policies
are to be applied to packets arriving at this port."
::= { sfpsL4CPPortEntry 3 }
sfpsL4CPPortApplyPolicyOut OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not access policies
are to be applied to packets sent out this port."
::= { sfpsL4CPPortEntry 4 }
sfpsL4CPPortDefaultUserID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last four octets of CSM's UserOID for the
default userid for this port."
::= { sfpsL4CPPortEntry 5 }
sfpsL4CPPortDefaultUserName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name assigned to MAC addresses
discovered on this port."
::= { sfpsL4CPPortEntry 6 }
-- SFPS Callable Device Table
sfpsL4CPCallableDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CPCallableDeviceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the attributes of a callable device."
::= { sfpsL4CP 11 }
sfpsL4CPCallableDeviceEntry OBJECT-TYPE
SYNTAX SfpsL4CPCallableDeviceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information about
one of this access server's ports."
INDEX { sfpsL4CPCallableDeviceDeviceID }
::= { sfpsL4CPCallableDeviceTable 1 }
SfpsL4CPCallableDeviceEntry ::=
SEQUENCE {
sfpsL4CPCallableDeviceDeviceID INTEGER,
sfpsL4CPCallableDeviceDeviceName DisplayString,
sfpsL4CPCallableDeviceDefaultUserName DisplayString
}
sfpsL4CPCallableDeviceDeviceID OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last four octets of CSM's DeviceOID for this
callable device."
::= { sfpsL4CPCallableDeviceEntry 1 }
sfpsL4CPCallableDeviceDeviceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default device name for this callable device."
::= { sfpsL4CPCallableDeviceEntry 2 }
sfpsL4CPCallableDeviceDefaultUserName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default user name for this callable device."
::= { sfpsL4CPCallableDeviceEntry 3 }
-- SFPS Layer 4 Call Detail Recording Active Flow Table
sfpsL4CDRActiveFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CDRActiveFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the currently active flows that have
Call Detail Recording enabled."
::= { sfpsL4CDR 4 }
sfpsL4CDRActiveFlowEntry OBJECT-TYPE
SYNTAX SfpsL4CDRActiveFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information about
one flow that has CDR enabled."
INDEX { sfpsL4CDRActiveFlowFlowID }
::= { sfpsL4CDRActiveFlowTable 1 }
SfpsL4CDRActiveFlowEntry ::=
SEQUENCE {
sfpsL4CDRActiveFlowFlowID INTEGER,
sfpsL4CDRActiveFlowSubProtocol INTEGER,
sfpsL4CDRActiveFlowEtherType INTEGER,
sfpsL4CDRActiveFlowSourceUser DisplayString,
sfpsL4CDRActiveFlowSourceMACAddr DisplayString,
sfpsL4CDRActiveFlowSourceNetAddr DisplayString,
sfpsL4CDRActiveFlowSourceProtocolPort INTEGER,
sfpsL4CDRActiveFlowSourcePPRangeEnabled INTEGER,
sfpsL4CDRActiveFlowSourceConnNumber INTEGER,
sfpsL4CDRActiveFlowDestUser DisplayString,
sfpsL4CDRActiveFlowDestMACAddr DisplayString,
sfpsL4CDRActiveFlowDestNetAddr DisplayString,
sfpsL4CDRActiveFlowDestProtocolPort INTEGER,
sfpsL4CDRActiveFlowDestPPRangeEnabled INTEGER,
sfpsL4CDRActiveFlowDestConnNumber INTEGER,
sfpsL4CDRActiveFlowStartTime TimeTicks,
sfpsL4CDRActiveFlowLastPktTime TimeTicks,
sfpsL4CDRActiveFlowEndTime TimeTicks,
sfpsL4CDRActiveFlowInOctets Counter,
sfpsL4CDRActiveFlowOutOctets Counter,
sfpsL4CDRActiveFlowInPkts Counter,
sfpsL4CDRActiveFlowOutPkts Counter,
sfpsL4CDRActiveFlowDemandAccessConnMade INTEGER,
sfpsL4CDRActiveFlowFlowRecordState INTEGER
}
sfpsL4CDRActiveFlowFlowID OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Flow ID for this flow."
::= { sfpsL4CDRActiveFlowEntry 1 }
sfpsL4CDRActiveFlowSubProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value identifies the Layer
4 protocol (for IP, this value corresponds to the 'Protocol'
field as described in the 'Assigned Numbers' RFC). If this
is a Layer 3 flow, this value is zero."
::= { sfpsL4CDRActiveFlowEntry 2 }
sfpsL4CDRActiveFlowEtherType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 protocol represented by this entry. Values
correspond to the 'Ether Type' field as described in the
Assigned Numbers RFC."
::= { sfpsL4CDRActiveFlowEntry 3 }
sfpsL4CDRActiveFlowSourceUser OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name associated with the source of the flow."
::= { sfpsL4CDRActiveFlowEntry 4 }
sfpsL4CDRActiveFlowSourceMACAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address associated with the source of the flow."
::= { sfpsL4CDRActiveFlowEntry 5 }
sfpsL4CDRActiveFlowSourceNetAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address associated with the source of the flow."
::= { sfpsL4CDRActiveFlowEntry 6 }
sfpsL4CDRActiveFlowSourceProtocolPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value indicates the
protocol port number of the source of the flow.
Otherwise, this field is zero."
::= { sfpsL4CDRActiveFlowEntry 7 }
sfpsL4CDRActiveFlowSourcePPRangeEnabled OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not any source protocol port
number greater than 1023 is considered to match the source
protocol port with which this flow was created."
::= { sfpsL4CDRActiveFlowEntry 8 }
sfpsL4CDRActiveFlowSourceConnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source connection number."
::= { sfpsL4CDRActiveFlowEntry 9 }
sfpsL4CDRActiveFlowDestUser OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name associated with the destination of the flow."
::= { sfpsL4CDRActiveFlowEntry 10 }
sfpsL4CDRActiveFlowDestMACAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address associated with the destination of the flow."
::= { sfpsL4CDRActiveFlowEntry 11 }
sfpsL4CDRActiveFlowDestNetAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address associated with the destination of the flow."
::= { sfpsL4CDRActiveFlowEntry 12 }
sfpsL4CDRActiveFlowDestProtocolPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value indicates the
protocol port number of the destination of the flow.
Otherwise, this field is zero."
::= { sfpsL4CDRActiveFlowEntry 13 }
sfpsL4CDRActiveFlowDestPPRangeEnabled OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not any destination protocol port
number greater than 1023 is considered to match the destination
protocol port with which this flow was created."
::= { sfpsL4CDRActiveFlowEntry 14 }
sfpsL4CDRActiveFlowDestConnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The destination connection number."
::= { sfpsL4CDRActiveFlowEntry 15 }
sfpsL4CDRActiveFlowStartTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since this flow was created."
::= { sfpsL4CDRActiveFlowEntry 16 }
sfpsL4CDRActiveFlowLastPktTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since the most recent packet was sent on
this flow."
::= { sfpsL4CDRActiveFlowEntry 17 }
sfpsL4CDRActiveFlowEndTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since this flow was terminated. This
field is not meaningful for active flows."
::= { sfpsL4CDRActiveFlowEntry 18 }
sfpsL4CDRActiveFlowInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets that have been sent from the
destination to the source."
::= { sfpsL4CDRActiveFlowEntry 19 }
sfpsL4CDRActiveFlowOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets that have been sent from the
source to the destination."
::= { sfpsL4CDRActiveFlowEntry 20 }
sfpsL4CDRActiveFlowInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have been sent from the
destination to the source."
::= { sfpsL4CDRActiveFlowEntry 21 }
sfpsL4CDRActiveFlowOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have been sent from the
source to the destination."
::= { sfpsL4CDRActiveFlowEntry 22 }
sfpsL4CDRActiveFlowDemandAccessConnMade OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not a demand access
connection had to be made for this flow."
::= { sfpsL4CDRActiveFlowEntry 23 }
sfpsL4CDRActiveFlowFlowRecordState OBJECT-TYPE
SYNTAX INTEGER { initialized(1),
active(2),
terminated(3),
invalid(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current state of the flow record."
::= { sfpsL4CDRActiveFlowEntry 24 }
-- SFPS Layer 4 Call Detail Recording Terminated Flow Table
sfpsL4CDRTermedFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CDRTermedFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the terminated flows that had
Call Detail Recording enabled."
::= { sfpsL4CDR 5 }
sfpsL4CDRTermedFlowEntry OBJECT-TYPE
SYNTAX SfpsL4CDRTermedFlowEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information about
one flow that had CDR enabled."
INDEX { sfpsL4CDRTermedFlowFlowID }
::= { sfpsL4CDRTermedFlowTable 1 }
SfpsL4CDRTermedFlowEntry ::=
SEQUENCE {
sfpsL4CDRTermedFlowFlowID INTEGER,
sfpsL4CDRTermedFlowSubProtocol INTEGER,
sfpsL4CDRTermedFlowEtherType INTEGER,
sfpsL4CDRTermedFlowSourceUser DisplayString,
sfpsL4CDRTermedFlowSourceMACAddr DisplayString,
sfpsL4CDRTermedFlowSourceNetAddr DisplayString,
sfpsL4CDRTermedFlowSourceProtocolPort INTEGER,
sfpsL4CDRTermedFlowSourcePPRangeEnabled INTEGER,
sfpsL4CDRTermedFlowSourceConnNumber INTEGER,
sfpsL4CDRTermedFlowDestUser DisplayString,
sfpsL4CDRTermedFlowDestMACAddr DisplayString,
sfpsL4CDRTermedFlowDestNetAddr DisplayString,
sfpsL4CDRTermedFlowDestProtocolPort INTEGER,
sfpsL4CDRTermedFlowDestPPRangeEnabled INTEGER,
sfpsL4CDRTermedFlowDestConnNumber INTEGER,
sfpsL4CDRTermedFlowStartTime TimeTicks,
sfpsL4CDRTermedFlowLastPktTime TimeTicks,
sfpsL4CDRTermedFlowEndTime TimeTicks,
sfpsL4CDRTermedFlowInOctets Counter,
sfpsL4CDRTermedFlowOutOctets Counter,
sfpsL4CDRTermedFlowInPkts Counter,
sfpsL4CDRTermedFlowOutPkts Counter,
sfpsL4CDRTermedFlowDemandAccessConnMade INTEGER,
sfpsL4CDRTermedFlowFlowRecordState INTEGER
}
sfpsL4CDRTermedFlowFlowID OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Flow ID for this flow."
::= { sfpsL4CDRTermedFlowEntry 1 }
sfpsL4CDRTermedFlowSubProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value identifies the Layer
4 protocol (for IP, this value corresponds to the 'Protocol'
field as described in the 'Assigned Numbers' RFC). If this
is a Layer 3 flow, this value is zero."
::= { sfpsL4CDRTermedFlowEntry 2 }
sfpsL4CDRTermedFlowEtherType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 protocol represented by this entry. Values
correspond to the 'Ether Type' field as described in the
Assigned Numbers RFC."
::= { sfpsL4CDRTermedFlowEntry 3 }
sfpsL4CDRTermedFlowSourceUser OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name associated with the source of the flow."
::= { sfpsL4CDRTermedFlowEntry 4 }
sfpsL4CDRTermedFlowSourceMACAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address associated with the source of the flow."
::= { sfpsL4CDRTermedFlowEntry 5 }
sfpsL4CDRTermedFlowSourceNetAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address associated with the source of the flow."
::= { sfpsL4CDRTermedFlowEntry 6 }
sfpsL4CDRTermedFlowSourceProtocolPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value indicates the
protocol port number of the source of the flow.
Otherwise, this field is zero."
::= { sfpsL4CDRTermedFlowEntry 7 }
sfpsL4CDRTermedFlowSourcePPRangeEnabled OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not any source protocol port
number greater than 1023 is considered to match the source
protocol port with which this flow was created."
::= { sfpsL4CDRTermedFlowEntry 8 }
sfpsL4CDRTermedFlowSourceConnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source connection number."
::= { sfpsL4CDRTermedFlowEntry 9 }
sfpsL4CDRTermedFlowDestUser OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name associated with the destination of the flow."
::= { sfpsL4CDRTermedFlowEntry 10 }
sfpsL4CDRTermedFlowDestMACAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address associated with the destination of the flow."
::= { sfpsL4CDRTermedFlowEntry 11 }
sfpsL4CDRTermedFlowDestNetAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Layer 3 address associated with the destination of the flow."
::= { sfpsL4CDRTermedFlowEntry 12 }
sfpsL4CDRTermedFlowDestProtocolPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is a Layer 4 flow, this value indicates the
protocol port number of the destination of the flow.
Otherwise, this field is zero."
::= { sfpsL4CDRTermedFlowEntry 13 }
sfpsL4CDRTermedFlowDestPPRangeEnabled OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not any destination protocol port
number greater than 1023 is considered to match the destination
protocol port with which this flow was created."
::= { sfpsL4CDRTermedFlowEntry 14 }
sfpsL4CDRTermedFlowDestConnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The destination connection number."
::= { sfpsL4CDRTermedFlowEntry 15 }
sfpsL4CDRTermedFlowStartTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since this flow was created."
::= { sfpsL4CDRTermedFlowEntry 16 }
sfpsL4CDRTermedFlowLastPktTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since the most recent packet was sent on
this flow."
::= { sfpsL4CDRTermedFlowEntry 17 }
sfpsL4CDRTermedFlowEndTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since this flow was terminated."
::= { sfpsL4CDRTermedFlowEntry 18 }
sfpsL4CDRTermedFlowInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets that have been sent from the
destination to the source."
::= { sfpsL4CDRTermedFlowEntry 19 }
sfpsL4CDRTermedFlowOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets that have been sent from the
source to the destination."
::= { sfpsL4CDRTermedFlowEntry 20 }
sfpsL4CDRTermedFlowInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have been sent from the
destination to the source."
::= { sfpsL4CDRTermedFlowEntry 21 }
sfpsL4CDRTermedFlowOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that have been sent from the
source to the destination."
::= { sfpsL4CDRTermedFlowEntry 22 }
sfpsL4CDRTermedFlowDemandAccessConnMade OBJECT-TYPE
SYNTAX INTEGER { yes(1),
no(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether or not a demand access
connection had to be made for this flow."
::= { sfpsL4CDRTermedFlowEntry 23 }
sfpsL4CDRTermedFlowFlowRecordState OBJECT-TYPE
SYNTAX INTEGER { initialized(1),
active(2),
terminated(3),
invalid(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current state of the flow record."
::= { sfpsL4CDRTermedFlowEntry 24 }
-- SFPS Layer 4 Call Detail Recording Flow Index Table
sfpsL4CDRFlowIndexTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpsL4CDRFlowIndexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the current flows that have
Call Detail Recording enabled."
::= { sfpsL4CDR 6 }
sfpsL4CDRFlowIndexEntry OBJECT-TYPE
SYNTAX SfpsL4CDRFlowIndexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains information about
one flow that has CDR enabled."
INDEX { sfpsL4CDRFlowIndexFlowID }
::= { sfpsL4CDRFlowIndexTable 1 }
SfpsL4CDRFlowIndexEntry ::=
SEQUENCE {
sfpsL4CDRFlowIndexFlowID INTEGER,
sfpsL4CDRFlowIndexSFPSFlowTblIndex INTEGER,
sfpsL4CDRFlowIndexSFlowStatsPtr INTEGER,
sfpsL4CDRFlowIndexStaticFlowInfoPtr INTEGER,
sfpsL4CDRFlowIndexFlowTblEntryPtr INTEGER,
sfpsL4CDRFlowIndexFlowState INTEGER
}
sfpsL4CDRFlowIndexFlowID OBJECT-TYPE
SYNTAX INTEGER(0..'7FFFFFFF'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Flow ID for this flow."
::= { sfpsL4CDRFlowIndexEntry 1 }
sfpsL4CDRFlowIndexSFPSFlowTblIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of the SFPS Flow Table entry (1-based) that
corresponds to this flow."
::= { sfpsL4CDRFlowIndexEntry 2 }
sfpsL4CDRFlowIndexSFlowStatsPtr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pointer to the SFlowStats object for this flow."
::= { sfpsL4CDRFlowIndexEntry 3 }
sfpsL4CDRFlowIndexStaticFlowInfoPtr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pointer to the L4CDRStaticFlowInfo object for this flow."
::= { sfpsL4CDRFlowIndexEntry 4 }
sfpsL4CDRFlowIndexFlowTblEntryPtr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The flow table entry pointer for this flow."
::= { sfpsL4CDRFlowIndexEntry 5 }
sfpsL4CDRFlowIndexFlowState OBJECT-TYPE
SYNTAX INTEGER { initialized(1),
active(2),
terminated(3),
invalid(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current state of the flow index record."
::= { sfpsL4CDRFlowIndexEntry 6 }
END