mibs/MIBS/enterasys/CTTRAPLOG-MIB

474 lines
16 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CTTRAPLOG-MIB DEFINITIONS ::= BEGIN
-- cttraplog-mib.txt
-- Revision: 01.00.02
-- Part Number:
-- Date: July 17, 1998
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific trap log mib.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright July 1998 Cabletron Systems
-- PLEASE NOTE: All groups in this mib are optional
IMPORTS
DisplayString
FROM RFC1213-MIB
Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
ctTrapLog
FROM CTRON-MIB-NAMES;
totalNumberOfEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of logged entries for this chassis."
::= { ctTrapLog 1 }
configTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigTableEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 2 }
configTableEntry OBJECT-TYPE
SYNTAX ConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry allows a user to configure the alarm table
for a specific slot. Objects such as Current Entry,
MaxEntries Allowed, and an Enable/Disable switch are
available."
INDEX { slotInChassis }
::= { configTable 1 }
ConfigTableEntry ::=
SEQUENCE {
slotInChassis
INTEGER,
numEntriesLoggeds
Counter,
numEntriesRequested
INTEGER,
numEntriesAllocated
INTEGER,
lastLoggedEntryLogId
INTEGER,
logCommand
INTEGER,
wrap
INTEGER
}
slotInChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each Slot can be separately configured. This is the
slot number for the configuration entry. "
::= { configTableEntry 1 }
numEntriesLoggeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the total number of entries looged for this
slot."
::= { configTableEntry 2 }
numEntriesRequested OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum number of entries to store before wrapping
the log on this slot."
::= { configTableEntry 3 }
numEntriesAllocated OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the number of entries allocated to log alarms
on this slot. It will always be less than or equal
to the requested number of entries."
::= { configTableEntry 4 }
lastLoggedEntryLogId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the log id of the last entry logged for this
slot."
::= { configTableEntry 5 }
logCommand OBJECT-TYPE
SYNTAX INTEGER {
clearLog (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows the user to send the log the commands
specified in the enumeration."
::= { configTableEntry 6 }
wrap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is whether or not this configuration has
wrapped or not."
::= { configTableEntry 7 }
trapLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapLogEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 3 }
trapLogEntry OBJECT-TYPE
SYNTAX TrapLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each alarm entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. "
INDEX { slotChassis,
logId }
::= { trapLogTable 1 }
TrapLogEntry ::=
SEQUENCE {
logId
INTEGER,
nvmpId
INTEGER,
trapLogAcknowledged
INTEGER,
trapLogVarBind
OCTET STRING,
trapLogDescription
DisplayString,
timeLogged
TimeTicks,
filterId
INTEGER,
slotChassis
INTEGER,
trapOID
OBJECT IDENTIFIER,
z80Time
TimeTicks
}
logId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each slot has a maximium number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number
of entries for a slot is reached, the log wraps. Each
new entry will replace the oldest entry for that slot."
::= { trapLogEntry 1 }
nvmpId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the nvmp id of the trap that occurred."
::= { trapLogEntry 2 }
trapLogAcknowledged OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is set to 2 if a trap as been acknowledged
from the EM."
::= { trapLogEntry 3 }
trapLogVarBind OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1500))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap. "
::= { trapLogEntry 4 }
trapLogDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an internally defined string used to describe
an alarm. Its primary use is for display on the EMs
LCD. A default value will be used for the old trap
calls."
::= { trapLogEntry 5 }
timeLogged OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time the entry was logged. This will be date and
time if possible."
::= { trapLogEntry 6 }
filterId OBJECT-TYPE
SYNTAX INTEGER {
informational (1),
warning (2),
severe (3),
fatal (4),
existing (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This will be used to filter certain alarms. The
criteria is TBD. An example of classification:
informational - requires no intervention. warning -
Does not require immediate intervention. e.g. static
risk severe - Requires immediate intervention. e.g.
power overload. fatal - Requires attention and
module may take corrective action such as reboot. e.g.
Unrecoverable software or hardware error. "
::= { trapLogEntry 7 }
slotChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of this trap log."
::= { trapLogEntry 8 }
trapOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID."
::= { trapLogEntry 9 }
z80Time OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the time that the Z80 has been up for the
board that sent this trap."
::= { trapLogEntry 10 }
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 4 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each filter entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. "
INDEX { filterSlotInChassis,
filterFilterId,
filterLogId }
::= { filterTable 1 }
FilterEntry ::=
SEQUENCE {
filterLogId
INTEGER,
filterNvmpId
INTEGER,
filterTrapLogAcknowledged
INTEGER,
filterTrapLogVarBind
OCTET STRING,
filterTrapLogDescription
DisplayString,
filterTimeLogged
TimeTicks,
filterFilterId
INTEGER,
filterSlotInChassis
INTEGER,
filterTrapOID
OBJECT IDENTIFIER,
filterZ80Time
TimeTicks
}
filterLogId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each slot has a maximum number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number of
entries for a slot is reached, the log wraps. Each new
entry willreplace the oldest entry for that slot."
::= { filterEntry 1 }
filterNvmpId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the nvmp id of the trap that was
generated."
::= { filterEntry 2 }
filterTrapLogAcknowledged OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is non-zero if a trap has been acknowleged
from the EM."
::= { filterEntry 3 }
filterTrapLogVarBind OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1500))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap."
::= { filterEntry 4 }
filterTrapLogDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an internally defined string used to
describe an alarm. It's primary use is for display
on the EMs LCD. A default value will be used for
the old trap calls."
::= { filterEntry 5 }
filterTimeLogged OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time the entry was logged. This will be date
and time if possible."
::= { filterEntry 6 }
filterFilterId OBJECT-TYPE
SYNTAX INTEGER {
informational (1),
warning (2),
severe (3),
fatal (4),
existing (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This will be used tofilter certain alarms. The
criteria is TBD. An example of classification:
informational-requires no intervention. warning -
Does not require immediate intervention. e.g.
statis risk severe - Requires immediate
intervention. e.g. power overload. fatal -
Requires attention and module may take
corrective action such as reboot. e.g. Unrecoverale
software or hardware error."
::= { filterEntry 7 }
filterSlotInChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of this filter entry."
::= { filterEntry 8 }
filterTrapOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID."
::= { filterEntry 9 }
filterZ80Time OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of time ticks that have passed since
this boards Z80 processor has been up."
::= { filterEntry 10 }
trapLoggerAgent OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
standby(3),
elected(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reflects the operational status of the traplogger agent"
::= { ctTrapLog 5 }
END