PT-RADIOLINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,OBJECT-TYPE,Counter32, Integer32, IpAddress FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
InetAddressIPv6 FROM INET-ADDRESS-MIB
ifEntry FROM IF-MIB
pt FROM PT-MIB;
ptRadioLink MODULE-IDENTITY
LAST-UPDATED "201712011600Z"
ORGANIZATION "Ericsson"
CONTACT-INFO
"Anders Ekvall
Postal: Ericsson AB,
E-Mail: anders.ekvall@ericsson.com"
DESCRIPTION
"This is the MIB for Radio Link specifics in PT"
REVISION "201712011600Z"
DESCRIPTION
"Added plcAdminStatus and plcOperStatus."
REVISION "201704051000Z"
DESCRIPTION
"Added channelSpacing enums."
REVISION "201701181000Z"
DESCRIPTION
"Added mlhcAdminStatus, mlhcOperStatus and mlhcMplsConfig."
REVISION "201612061400Z"
DESCRIPTION
"Added more MOs in ctTable and rltTable. Added G.826 tables."
REVISION "201605221030Z"
DESCRIPTION
"The initial version of this MIB module
with OID for MINI-LINK."
::= { pt 7 }
ptRadioLinkConformance OBJECT IDENTIFIER ::= { ptRadioLink 2 }
ctPerformance OBJECT IDENTIFIER ::= { ptRadioLink 4 }
---
--- Textual conventions
---
AcmTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer which indicates the ACM."
SYNTAX INTEGER
{
acmHalfBpsk(1),
acmHalfBpskLight(2),
acmHalfBpskStrong(3),
acmBpsk(4),
acmBpskLight(5),
acmBpskStrong(6),
acm4Qam(7),
acm4QamLight(8),
acm4QamStrong(9),
acm16Qam(10),
acm16QamLight(11),
acm16QamStrong(12),
acm32Qam(13),
acm32QamLight(14),
acm32QamStrong(15),
acm64Qam(16),
acm64QamLight(17),
acm64QamStrong(18),
acm128Qam(19),
acm128QamLight(20),
acm128QamStrong(21),
acm256Qam(22),
acm256QamLight(23),
acm256QamStrong(24),
acm512Qam(25),
acm512QamLight(26),
acm512QamStrong(27),
acm1024Qam(28),
acm1024QamLight(29),
acm1024QamStrong(30),
acm2048Qam(31),
acm2048QamLight(32),
acm2048QamStrong(33),
acm4096Qam(34),
acm4096QamLight(35),
acm4096QamStrong(36)
}
EnableStatusTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer which indicates the enabled status."
SYNTAX INTEGER
{
enabled(1),
disabled(2),
unknown(3)
}
XpicMimoTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer which indicates the XPIC or MIMO status."
SYNTAX INTEGER
{
notAvailable(1),
locked(2),
unlocked(3),
unknown(4)
}
---
---The definition of ctTable
---
ctTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of CT Table entries."
::= { ptRadioLink 1 }
ctEntry OBJECT-TYPE
SYNTAX CtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of CT application."
AUGMENTS { ifEntry }
::= { ctTable 1 }
CtEntry ::=
SEQUENCE {
actualInputPower OCTET STRING,
actualOutputPower OCTET STRING,
actualRxAcm OCTET STRING,
actualTxAcm OCTET STRING,
ctDistinguishedName OCTET STRING,
description OCTET STRING,
carrierId INTEGER,
ctStatus INTEGER,
frameId Integer32,
txFrequency Integer32,
minTxFrequency Integer32,
maxTxFrequency Integer32,
rxFrequency Integer32,
minRxFrequency Integer32,
maxRxFrequency Integer32,
frequencyStepSize Integer32,
duplexDistance Integer32,
duplexType INTEGER,
duplexConfig EnableStatusTC,
autoFreqSelection INTEGER,
autoFreqSelectedChannel Integer32,
autoFreqSelectionStatus INTEGER,
channelSpacing INTEGER,
polarization INTEGER,
txOperStatus INTEGER,
txAdminStatus INTEGER,
selectedOutputPowerType INTEGER,
availableOutputPowerType INTEGER,
selectedMinOutputPower Integer32,
selectedMaxOutputPower Integer32,
availableMinOutputPower Integer32,
availableMaxOutputPower Integer32,
referenceSec INTEGER,
targetInputPowerFarEnd Integer32,
berAlarmThreshold INTEGER,
inputPowerAlarmThreshold Integer32,
plannedAlignmentInputPower Integer32,
atpcFallback EnableStatusTC,
atpcFallbackTimer Integer32,
atpcFallbackOutputPower Integer32,
xpicStatus XpicMimoTC,
mimoStatus XpicMimoTC,
actualSnir OCTET STRING,
actualXpi OCTET STRING,
actualSi OCTET STRING,
actualTxCapacity Integer32,
licensedCapacity Integer32,
availableMinCapacity Integer32,
availableMaxCapacity Integer32,
selectedMinCapacity Integer32,
selectedMaxCapacity Integer32,
wantedLicensedCapacity Integer32,
availableMinAcm AcmTC,
availableMaxAcm AcmTC,
selectedMinAcm AcmTC,
selectedMaxAcm AcmTC,
actualRxAcmTC AcmTC,
actualTxAcmTC AcmTC,
alignmentMode EnableStatusTC,
rfLoop EnableStatusTC
}
actualInputPower OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual input power of the CT in dBm"
::= { ctEntry 1 }
actualOutputPower OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual output power of the CT in dBm"
::= { ctEntry 2 }
actualRxAcm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual rx modulation and coding"
::= { ctEntry 3 }
actualTxAcm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual tx modulation and coding"
::= { ctEntry 4 }
ctDistinguishedName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)"
::= { ctEntry 5 }
description OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User description of the carrior termination."
::= { ctEntry 6 }
carrierId OBJECT-TYPE
SYNTAX INTEGER
{
a(1),
b(2),
c(3),
d(4),
unknown(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Id of the carrier. (A, B, C, D)
Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination.
Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC.
Sometimes also referred to as preamble"
::= { ctEntry 7 }
ctStatus OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2),
na(3),
unknown(4),
degraded(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the carrier termination, hop"
::= { ctEntry 8}
frameId OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique identifier for the radio frame to be used.
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
::= { ctEntry 9}
txFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected frequency on the transmitter (kHz).
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
::= { ctEntry 10}
minTxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum Tx frequency possible to use, given by the selected frame-id"
::= { ctEntry 11}
maxTxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Tx frequency possible to use, given by the selected frame-id"
::= { ctEntry 12}
rxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected frequency on the receiver (kHz).
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
::= { ctEntry 13}
minRxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum Rx frequency possible to use, given by the selected frame-id"
::= { ctEntry 14}
maxRxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Rx frequency possible to use, given by the selected frame-id"
::= { ctEntry 15}
frequencyStepSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency step size in kHz"
::= { ctEntry 16}
duplexDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance between Tx and Rx frequencies (kHz)"
::= { ctEntry 17}
duplexType OBJECT-TYPE
SYNTAX INTEGER
{
variable(1),
fixed(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duplex type is given by the equipment (Fixed,Variable)"
::= { ctEntry 18}
duplexConfig OBJECT-TYPE
SYNTAX EnableStatusTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling or disabling configuration of Rx freq using duplex distance"
::= { ctEntry 19}
autoFreqSelection OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
master(2),
slave(3),
unknown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Automatic frequency selection mode"
::= { ctEntry 20}
autoFreqSelectedChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Automatic frequency selected channel"
::= { ctEntry 21}
autoFreqSelectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
searchingForSlave(2),
requestingInfoFromSlave(3),
waitingForMaster(4),
waitingForChannelInfoRequest(5),
inProgress(6),
initializing(7),
finished(8),
failed(9),
unknown(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Automatic frequency status"
::= { ctEntry 22}
channelSpacing OBJECT-TYPE
SYNTAX INTEGER
{
cs7MHz(1),
cs10MHz(2),
cs14MHz(3),
cs20MHz(4),
cs28MHz(5),
cs30MHz(6),
cs40MHz(7),
cs50MHz(8),
cs56MHz(9),
cs250MHz(10),
cs60MHz(11),
cs500MHz(12),
cs750MHz(13),
cs100MHz(14),
cs150MHz(15),
cs200MHz(16),
cs125MHz(17),
cs80MHz(18),
cs112MHz(19),
cs1000MHz(20),
cs1250MHz(21),
cs1500MHz(22),
cs62p5MHz(23),
cs2000MHz(24),
unknown(25)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel spacing"
::= { ctEntry 23}
polarization OBJECT-TYPE
SYNTAX INTEGER
{
notSpecified(1),
horizontal(2),
vertical(3),
unknown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Antenna polarization"
::= { ctEntry 24}
txOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
off(2),
on(3),
standby(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operative status of the transmitter"
::= { ctEntry 25}
txAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative status of the transmitter"
::= { ctEntry 26}
selectedOutputPowerType OBJECT-TYPE
SYNTAX INTEGER
{
standard(1),
high(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected output power type"
::= { ctEntry 27}
availableOutputPowerType OBJECT-TYPE
SYNTAX INTEGER
{
standard(1),
high(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Available output power type"
::= { ctEntry 28}
selectedMinOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected min output power.
Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
::= { ctEntry 29}
selectedMaxOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected max output power.
Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
::= { ctEntry 30}
availableMinOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum output power supported (dBm).
The system shows a value if the equipment is available and a frame id has been selected."
::= { ctEntry 31}
availableMaxOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum output power supported (dBm).
The system shows a value if the equipment is available and a frame id has been selected."
::= { ctEntry 32}
referenceSec OBJECT-TYPE
SYNTAX INTEGER
{
noAvailable(1),
sec2(2),
sec4L(4),
sec4H(5),
sec5B(7),
sec6B(9),
sec5LB(10),
sec5HB(11),
sec6LB(12),
sec6HB(13),
sec7B(14),
unknown(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC).
When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM.
This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements.
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
::= { ctEntry 33}
targetInputPowerFarEnd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted input power at far end (dBm), when running ATPC"
::= { ctEntry 34}
berAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER
{
tenExpMinus6(1),
tenExpMinus3(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for the BER alarm"
::= { ctEntry 35}
inputPowerAlarmThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for the input power alarm"
::= { ctEntry 36}
plannedAlignmentInputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power.
Used when doing alignment"
::= { ctEntry 37}
atpcFallback OBJECT-TYPE
SYNTAX EnableStatusTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the output power fall back function"
::= { ctEntry 38}
atpcFallbackTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the timer for output power fall back (# of seconds)"
::= { ctEntry 39}
atpcFallbackOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ATPC fallback output power"
::= { ctEntry 40}
xpicStatus OBJECT-TYPE
SYNTAX XpicMimoTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the XPIC function."
::= { ctEntry 41}
mimoStatus OBJECT-TYPE
SYNTAX XpicMimoTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the MIMO function."
::= { ctEntry 42}
actualSnir OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual signal to noise plus interference ratio (dB)."
::= { ctEntry 43}
actualXpi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The carrier to cross-polar interference level (dBc)."
::= { ctEntry 44}
actualSi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spatial interference between the CTs when MIMO is configured."
::= { ctEntry 45}
actualTxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual capacity supported by the carrier termination."
::= { ctEntry 46}
licensedCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wanted or installed license for the capacity allowed for the carrier termination."
::= { ctEntry 47}
availableMinCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum capacity possible to use. Given by the selected frame-id (kbit/s)"
::= { ctEntry 48}
availableMaxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum capacity possible to use. Given by the selected frame-id (kbit/s)"
::= { ctEntry 49}
selectedMinCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selected minimum capacity, derived from selected minimum ACM (kbit/s)"
::= { ctEntry 50}
selectedMaxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selected maximum capacity, derived from selected maximum ACM (kbit/s)"
::= { ctEntry 51}
wantedLicensedCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)"
::= { ctEntry 52}
availableMinAcm OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum ACM possible to use, given by the selected frame id."
::= { ctEntry 53}
availableMaxAcm OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum ACM possible to use, given by the selected frame id"
::= { ctEntry 54}
selectedMinAcm OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
::= { ctEntry 55}
selectedMaxAcm OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
::= { ctEntry 56}
actualRxAcmTC OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual rx modulation and coding"
::= { ctEntry 57}
actualTxAcmTC OBJECT-TYPE
SYNTAX AcmTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual tx modulation and coding"
::= { ctEntry 58}
alignmentMode OBJECT-TYPE
SYNTAX EnableStatusTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the alignment mode"
::= { ctEntry 59}
rfLoop OBJECT-TYPE
SYNTAX EnableStatusTC
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the rf loop"
::= { ctEntry 60}
---
---The definition of rltTable
---
rltTable OBJECT-TYPE
SYNTAX SEQUENCE OF RltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of RLT Table entries."
::= { ptRadioLink 3 }
rltEntry OBJECT-TYPE
SYNTAX RltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of RLT application."
AUGMENTS { ifEntry }
::= { rltTable 1 }
RltEntry ::=
SEQUENCE {
rltDistinguishedName OCTET STRING,
neIpAddress IpAddress,
neIpv6Address InetAddressIPv6,
neName OCTET STRING,
neType INTEGER,
id OCTET STRING,
rltStatus INTEGER,
mode INTEGER,
actualTxTotalCapacity Integer32,
limitedTotalCapacity Integer32,
protectionStatus INTEGER,
revertiveWaitToRestore Integer32,
revertivePreferredTx INTEGER,
protectionSwitchMode INTEGER,
fadeNotificationTimer Integer32,
expectedFarEndId OCTET STRING,
farEndIdCheck INTEGER,
cpriMode INTEGER,
cpriStatus INTEGER,
manualSwitch INTEGER,
mlhcOperStatus INTEGER,
mlhcAdminStatus INTEGER,
mlhcMplsConfig INTEGER,
plcOperStatus INTEGER,
plcAdminStatus INTEGER
}
rltDistinguishedName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)"
::= { rltEntry 1 }
neIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NE IP address"
::= { rltEntry 2 }
neIpv6Address OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NE IP V6 address"
::= { rltEntry 3 }
neName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NE Name"
::= { rltEntry 4 }
neType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
mle(2),
xfMle(3),
tn(4),
cn(5),
pt(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NE Type"
::= { rltEntry 5 }
id OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined id of the radio link terminal"
::= { rltEntry 6}
rltStatus OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2),
na(3),
unknown(4),
degraded(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the radio link terminal"
::= { rltEntry 7}
mode OBJECT-TYPE
SYNTAX INTEGER
{
mode1plus0(1),
mode1plus1CSB(2),
mode1plus1RLP(3),
mode2plus0RLB(4),
mode2plus1CSB(5),
mode2plus1RLP(6),
mode2plus2CSB(7),
mode2plus2RLP(8),
mode3plus0RLB(9),
mode4plus0RLB(10),
notAvailable11(11),
notAvailable12(12),
notAvailable13(13),
notAvailable14(14),
mode3plus1RLP(15),
mode3plus2RLP(16),
mode3plus3RLP(17),
mode4plus1RLP(18),
mode4plus2RLP(19),
mode4plus3RLP(20),
mode4plus4RLP(21),
notAvailable22(22),
notAvailable23(23),
notAvailable24(24),
notAvailable25(25),
notAvailable26(26),
notAvailable27(27),
mode3plus1CSB(28),
mode3plus2CSB(29),
mode3plus3CSB(30),
mode4plus1CSB(31),
mode4plus2CSB(32),
mode4plus3CSB(33),
mode4plus4CSB(34),
unknown(35)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the radio link terminal"
::= { rltEntry 8}
actualTxTotalCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination.
Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment."
::= { rltEntry 9 }
limitedTotalCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum total capacity allowed by the current configuration and installed licenses.
Aggregated from the constituent carrier termination values."
::= { rltEntry 10 }
protectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
unprotected(1),
protected(2),
unableToProtect(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of a protected node."
::= { rltEntry 11}
revertiveWaitToRestore OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time, in number of seconds, to wait before switching back to the preferred Tx."
::= { rltEntry 12}
revertivePreferredTx OBJECT-TYPE
SYNTAX INTEGER
{
ct11(1),
ct12(2),
ct21(3),
ct22(4),
notApplicable(5),
unknown(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The preferred carrier termination transmitter."
::= { rltEntry 13}
protectionSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
manual(2),
autoAndRevertive(3),
unknown(4),
notApplicable(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
".The mode in which the switching mechanism is configured"
::= { rltEntry 14}
fadeNotificationTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Notification is sent if fading is longer than this timer, applicable for protection."
::= { rltEntry 15}
expectedFarEndId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Expected id of far-end terminal"
::= { rltEntry 16 }
farEndIdCheck OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling of far end id check."
::= { rltEntry 17}
cpriMode OBJECT-TYPE
SYNTAX INTEGER
{
master(1),
slave(2),
notApplicable(3),
unknown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the mode of the CPRI front-haul product."
::= { rltEntry 18}
cpriStatus OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
waitingOnRtcSync(2),
waitingOnCpri(3),
waitingOnRxRequest(4),
waitingOnTxRequest(5),
inSync(6),
unknown(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the CPRI front-haul product."
::= { rltEntry 19}
manualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
ct11(1),
ct12(2),
ct21(3),
ct22(4),
notApplicable(5),
unknown(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual switch of protected carrier termination transmitter."
::= { rltEntry 20}
mlhcOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operative status of multi layer header compression."
::= { rltEntry 21}
mlhcAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative status of multi layer header compression."
::= { rltEntry 22}
mlhcMplsConfig OBJECT-TYPE
SYNTAX INTEGER
{
controlWord(1),
l2(2),
l3(3),
mplsOnly(4),
unknown(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MLHC/MPLS configuration."
::= { rltEntry 23}
plcOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operative status of payload compression."
::= { rltEntry 24}
plcAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative status of payload compression."
::= { rltEntry 25}
---
---The definition of ct826ContinuousTable
---
ctG826ContinuousTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtG826ContinuousEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of CT G826 Performance Continuous counters entries.
The counters are reset by ctG826Reset"
::= { ctPerformance 1 }
ctG826ContinuousEntry OBJECT-TYPE
SYNTAX CtG826ContinuousEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of CT G826 Performance Continuous counters."
AUGMENTS { ifEntry }
::= { ctG826ContinuousTable 1 }
CtG826ContinuousEntry ::=
SEQUENCE {
ctG826TimeElapsed Counter32,
ctBBE Counter32,
ctBBER OCTET STRING,
ctES Counter32,
ctESR OCTET STRING,
ctSES Counter32,
ctSESR OCTET STRING,
ctBB OCTET STRING,
ctUAS Counter32,
ctG826Reset INTEGER
}
ctG826TimeElapsed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time elapsed in seconds since last PMReset"
::= { ctG826ContinuousEntry 1 }
ctBBE OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors"
::= { ctG826ContinuousEntry 2 }
ctBBER OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors Ratio"
::= { ctG826ContinuousEntry 3 }
ctES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds"
::= { ctG826ContinuousEntry 4 }
ctESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds Ratio"
::= { ctG826ContinuousEntry 5 }
ctSES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds"
::= { ctG826ContinuousEntry 6 }
ctSESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds Ratio"
::= { ctG826ContinuousEntry 7 }
ctBB OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background blocks"
::= { ctG826ContinuousEntry 8 }
ctUAS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unavailable seconds "
::= { ctG826ContinuousEntry 9 }
ctG826Reset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
noReset(2),
reset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the continuous PM counters"
::= { ctG826ContinuousEntry 10 }
---
---The definition of ctG826Current15mTable
---
ctG826Current15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtG826Current15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of CT Performance G826 15 m current counters Table entries."
::= { ctPerformance 2 }
ctG826Current15mEntry OBJECT-TYPE
SYNTAX CtG826Current15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of CT Performance G826 15 m current Table counters."
AUGMENTS { ifEntry }
::= { ctG826Current15mTable 1 }
CtG826Current15mEntry ::=
SEQUENCE {
ctG826Current15mTimeElapsed Counter32,
ctCurrent15mBBE Counter32,
ctCurrent15mBBER OCTET STRING,
ctCurrent15mES Counter32,
ctCurrent15mESR OCTET STRING,
ctCurrent15mSES Counter32,
ctCurrent15mSESR OCTET STRING,
ctCurrent15mBB Counter32,
ctCurrent15mUAS Counter32
}
ctG826Current15mTimeElapsed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time elapsed in seconds since last PMReset"
::= { ctG826Current15mEntry 1 }
ctCurrent15mBBE OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors"
::= { ctG826Current15mEntry 2 }
ctCurrent15mBBER OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors Ratio"
::= { ctG826Current15mEntry 3 }
ctCurrent15mES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds"
::= { ctG826Current15mEntry 4 }
ctCurrent15mESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds Ratio"
::= { ctG826Current15mEntry 5 }
ctCurrent15mSES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds"
::= { ctG826Current15mEntry 6 }
ctCurrent15mSESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds Ratio"
::= { ctG826Current15mEntry 7 }
ctCurrent15mBB OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background blocks"
::= { ctG826Current15mEntry 8 }
ctCurrent15mUAS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unavailable seconds "
::= { ctG826Current15mEntry 9 }
---
---The definition of ctG826Current24hTable
---
ctG826Current24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtG826Current24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of CT Performance G826 Current 24h counters entries."
::= { ctPerformance 3 }
ctG826Current24hEntry OBJECT-TYPE
SYNTAX CtG826Current24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of CT Performance G826 Current 24 h counters."
AUGMENTS { ifEntry }
::= { ctG826Current24hTable 1 }
CtG826Current24hEntry ::=
SEQUENCE {
ctG826Current24hTimeElapsed Counter32,
ctCurrent24hBBE Counter32,
ctCurrent24hBBER OCTET STRING,
ctCurrent24hES Counter32,
ctCurrent24hESR OCTET STRING,
ctCurrent24hSES Counter32,
ctCurrent24hSESR OCTET STRING,
ctCurrent24hBB Counter32,
ctCurrent24hUAS Counter32
}
ctG826Current24hTimeElapsed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time elapsed in seconds since last PMReset"
::= { ctG826Current24hEntry 1 }
ctCurrent24hBBE OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors"
::= { ctG826Current24hEntry 2 }
ctCurrent24hBBER OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background Block Errors Ratio"
::= { ctG826Current24hEntry 3 }
ctCurrent24hES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds"
::= { ctG826Current24hEntry 4 }
ctCurrent24hESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error seconds Ratio"
::= { ctG826Current24hEntry 5 }
ctCurrent24hSES OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds"
::= { ctG826Current24hEntry 6 }
ctCurrent24hSESR OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Severely error seconds Ratio"
::= { ctG826Current24hEntry 7 }
ctCurrent24hBB OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Background blocks"
::= { ctG826Current24hEntry 8 }
ctCurrent24hUAS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unavailable seconds "
::= { ctG826Current24hEntry 9 }
--
-- Conformance
--
ptRadioLinkCompliances OBJECT IDENTIFIER ::= { ptRadioLinkConformance 1 }
ptRadioLinkGroups OBJECT IDENTIFIER ::= { ptRadioLinkConformance 2 }
ptRadioLinkFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement everything."
MODULE -- This Module
MANDATORY-GROUPS { ptRadioLinkCompleteGroup}
::= { ptRadioLinkCompliances 1 }
ptRadioLinkCompleteGroup OBJECT-GROUP
OBJECTS
{
actualInputPower,
actualOutputPower,
actualRxAcm,
actualRxAcmTC,
actualSi,
actualSnir,
actualTxAcm,
actualTxAcmTC,
actualTxCapacity,
actualTxTotalCapacity,
actualXpi,
alignmentMode,
atpcFallback,
atpcFallbackTimer,
atpcFallbackOutputPower,
autoFreqSelectedChannel,
autoFreqSelection,
autoFreqSelectionStatus,
availableMaxAcm,
availableMaxCapacity,
availableMaxOutputPower,
availableMinAcm,
availableMinCapacity,
availableMinOutputPower,
availableOutputPowerType,
berAlarmThreshold,
carrierId,
channelSpacing,
cpriMode,
cpriStatus,
ctDistinguishedName,
ctCurrent15mBB,
ctCurrent15mBBE,
ctCurrent15mBBER,
ctCurrent15mES,
ctCurrent15mESR,
ctCurrent15mSES,
ctCurrent15mSESR,
ctCurrent15mUAS,
ctG826Current15mTimeElapsed,
ctCurrent24hBB,
ctCurrent24hBBE,
ctCurrent24hBBER,
ctCurrent24hES,
ctCurrent24hESR,
ctCurrent24hSES,
ctCurrent24hSESR,
ctCurrent24hUAS,
ctG826Current24hTimeElapsed,
ctBB,
ctBBE,
ctBBER,
ctES,
ctESR,
ctG826Reset,
ctSES,
ctSESR,
ctG826TimeElapsed,
ctUAS,
ctStatus,
description,
duplexConfig,
duplexDistance,
duplexType,
expectedFarEndId,
fadeNotificationTimer,
farEndIdCheck,
frameId,
frequencyStepSize,
id,
inputPowerAlarmThreshold,
licensedCapacity,
limitedTotalCapacity,
manualSwitch,
maxRxFrequency,
maxTxFrequency,
mimoStatus,
minRxFrequency,
minTxFrequency,
mlhcAdminStatus,
mlhcMplsConfig,
mlhcOperStatus,
plcAdminStatus,
plcOperStatus,
mode,
neIpAddress,
neIpv6Address,
neName,
neType,
plannedAlignmentInputPower,
polarization,
protectionStatus,
protectionSwitchMode,
referenceSec,
revertivePreferredTx,
revertiveWaitToRestore,
rfLoop,
rltDistinguishedName,
rltStatus,
rxFrequency,
selectedMaxAcm,
selectedMaxCapacity,
selectedMaxOutputPower,
selectedMinAcm,
selectedMinCapacity,
selectedMinOutputPower,
selectedOutputPowerType,
targetInputPowerFarEnd,
txAdminStatus,
txFrequency,
txOperStatus,
wantedLicensedCapacity,
xpicStatus
}
STATUS current
DESCRIPTION
"A collection of all current objects in this MIB module."
::= { ptRadioLinkGroups 1 }