-- RBN-ENVMON-MIB Environmental Monitor MIB
--
-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
RBN-ENVMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32
FROM SNMPv2-SMI
DisplayString,
TruthValue,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
entPhysicalIndex
FROM ENTITY-MIB
rbnMgmt
FROM RBN-SMI;
rbnEnvMonMIB MODULE-IDENTITY
LAST-UPDATED "201210030000Z" -- October 3, 2012
ORGANIZATION "Ericsson AB."
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr.
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"The MIB used to genericially manage Environmental
Monitor functionality on network devices."
REVISION "201210030000Z" -- October 3, 2012
DESCRIPTION
"Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed."
REVISION "201101191800Z" -- Jan 19, 2011
DESCRIPTION
"Update CONTACT-INFO & ORGANIZATION. "
REVISION "201011110000Z" -- Nov 11, 2010
DESCRIPTION
"Add new Table rbnEntityTempSensorTable. This will display
the TempSensor Details for all the entities. "
REVISION "200601160000Z" -- January 16, 2006
DESCRIPTION
"Add textual convention RbnFanSpeed. Add new OIDs:
rbnFanUnitID
rbnFanUnitDescr
rbnFanSpeedCurrent
rbnEnvMonFanSpeedObjectGroup
rbnEnvMonMIBComplianceV4
"
REVISION "200206050000Z" -- June 5, 2002
DESCRIPTION
"Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
ranges on Integer32, and size for DisplayString types.
Restore the incorrectly deprecated OIDs to current, since they
are still supported."
REVISION "200107250000Z" -- July 25, 2001
DESCRIPTION
"Added new OIDs:
rbnFanStatus
rbnPowerStatus
rbnFanStatusChange
rbnPowerStatusChange
rbnEnvMonMIBObjectGroupV2
rbnEnvMonMIBNotificationGroupV2
rbnEnvMonMIBComplianceV3
Deprecated the OIDs:
rbnFanFail
rbnPowerFail
rbnFanFailChange
rbnPowerFailChange
rbnEnvMonMIBObjectGroup
rbnEnvMonMIBNotificationGroup
rbnEnvMonMIBComplianceV2
"
REVISION "200004240000Z" -- May 24, 2000
DESCRIPTION
"Added voltage and temperature sensor tables."
REVISION "199903100000Z" -- Mar 10, 1999
DESCRIPTION
"Initial version."
::= { rbnMgmt 4 }
rbnEnvMonMIBNotifications OBJECT IDENTIFIER
::= { rbnEnvMonMIB 0 }
rbnEnvMonMIBObjects OBJECT IDENTIFIER
::= { rbnEnvMonMIB 1 }
rbnEnvMonMIBConformance OBJECT IDENTIFIER
::= { rbnEnvMonMIB 2 }
-- Textual Conventions
RbnVoltage ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a voltage value. The value is millivolts.
For example, a voltage of 5.5V would be represented
by the value 5500."
SYNTAX Unsigned32 (0..50000)
RbnTemperature ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Represents a temperature, in degrees Celsius. In the
unlikely event that the temperature to be reported is
less than 0 degrees Celsius, a value of 0 will be
used. Likewise, if the temperature is greater than
100, a value of 100 will be used."
SYNTAX Unsigned32 (0..100)
RbnFanSpeed ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a fan speed value in units of Revolutions Per
Minute(RPM)."
SYNTAX Unsigned32
-- MIB Objects
rbnFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan test point.
Note that there is not necessarily a one-to-one
relationship between fan test points and fan
assemblies; a single test point may be used to
monitor the status of multiple fans."
::= { rbnEnvMonMIBObjects 1 }
rbnFanStatusEntry OBJECT-TYPE
SYNTAX RbnFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan test point"
INDEX { rbnFanIndex }
::= { rbnFanStatusTable 1 }
RbnFanStatusEntry ::= SEQUENCE {
rbnFanIndex Integer32,
rbnFanDescr DisplayString,
rbnFanFail TruthValue,
rbnFanStatus INTEGER
}
rbnFanIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a fan test point."
::= { rbnFanStatusEntry 1 }
rbnFanDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a fan test point. If an instance of
this object is associated with a single fan assembly,
then the value of this object should be the same as the
name by which the assembly is normally referenced. If
an instance is associated with multiple fan assemblies,
then the value of this object should contain the names
of all of the fan assemblies being monitored."
::= { rbnFanStatusEntry 2 }
rbnFanFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value true, then a fan monitored
by the test point has failed. If an instance of
this object has the value false, then the fan (or fans)
monitored by the test point are operational."
::= { rbnFanStatusEntry 3 }
rbnFanStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value normal, then the fan (or
fans) monitored by the test point is operational. If
an instance of this object has the value failed, then
the fan (or fans) monitored by the test point has
failed. If an instance of this object has the value
absent, then the fan (or fans) monitored by this test
point is not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the fan (or fans)."
::= { rbnFanStatusEntry 4 }
rbnPowerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per power test point.
Note that there is not necessarily a one-to-one
relationship between power test points and power
supply assemblies; a single test point may be used
to monitor the status of multiple power supplies."
::= { rbnEnvMonMIBObjects 2 }
rbnPowerStatusEntry OBJECT-TYPE
SYNTAX RbnPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular power test point"
INDEX { rbnPowerIndex }
::= { rbnPowerStatusTable 1 }
RbnPowerStatusEntry ::= SEQUENCE {
rbnPowerIndex Integer32,
rbnPowerDescr DisplayString,
rbnPowerFail TruthValue,
rbnPowerStatus INTEGER
}
rbnPowerIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a power test point."
::= { rbnPowerStatusEntry 1 }
rbnPowerDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a power supply test point. If an
instance of this object is associated with a single
power supply assembly, then the value of this object
should be the same as the name by which the assembly
is normally referenced. If an instance is associated
with multiple power supply assemblies, then the value
of this object should contain the names of all of the
power supply assemblies being monitored."
::= { rbnPowerStatusEntry 2 }
rbnPowerFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value true, then a power supply
monitored by the test point has failed. If an instance
of this object has the value false, then the power
supply (or supplies) monitored by the test point are
operational."
::= { rbnPowerStatusEntry 3 }
rbnPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value normal, then the power
supply (or supplies) monitored by the test point is
operational. If an instance of this object has the
value failed, then the power supply (or supplies)
monitored by the test point has failed. If an instance
of this object has the value absent, then the power
supply (or supplies) monitored by this test point is
not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the power supply (or supplies)."
::= { rbnPowerStatusEntry 4 }
rbnVoltageSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per voltage test point.
Each physical entity (e.g. cards) in the system may
contain zero or more voltage test points."
::= { rbnEnvMonMIBObjects 3 }
rbnVoltageSensorEntry OBJECT-TYPE
SYNTAX RbnVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular voltage test point."
INDEX { entPhysicalIndex, rbnVoltageIndex }
::= { rbnVoltageSensorTable 1 }
RbnVoltageSensorEntry ::= SEQUENCE {
rbnVoltageIndex Integer32,
rbnVoltageDescr DisplayString,
rbnVoltageDesired RbnVoltage,
rbnVoltageCurrent RbnVoltage
}
rbnVoltageIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
voltage test point on a particular physical entity.
Index values for different test points are not
necessarily contiguous."
::= { rbnVoltageSensorEntry 1 }
rbnVoltageDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a voltage test point. Typically
an instance of this object will hold a user-friendly
description of the physical entity and the level of
voltage being monitored by this test point."
::= { rbnVoltageSensorEntry 2 }
rbnVoltageDesired OBJECT-TYPE
SYNTAX RbnVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The desired voltage level for this test point. If
the monitored voltage level (rbnVoltageCurrent) is
equal to this value, then the system is performing
as designed."
::= { rbnVoltageSensorEntry 3 }
rbnVoltageCurrent OBJECT-TYPE
SYNTAX RbnVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current voltage level at this test point."
::= { rbnVoltageSensorEntry 4 }
rbnCpuTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains one row per CPU temperature
sensor. Each physical entity in the system may have
zero or more CPUs. Each of those CPUs that has a
temperature sensor will show up here."
::= { rbnEnvMonMIBObjects 4 }
rbnCpuTempSensorEntry OBJECT-TYPE
SYNTAX RbnCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Information about a particular CPU temperature test
point."
INDEX { entPhysicalIndex, rbnCpuTempIndex }
::= { rbnCpuTempSensorTable 1 }
RbnCpuTempSensorEntry ::= SEQUENCE {
rbnCpuTempIndex Integer32,
rbnCpuTempDescr DisplayString,
rbnCpuTempCurrent RbnTemperature
}
rbnCpuTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An arbitrary value which uniquely identifies a CPU on
a particular physical entity. Index values for
different CPUs are not necessarily contiguous."
::= { rbnCpuTempSensorEntry 1 }
rbnCpuTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The description of a CPU temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
and a description of the CPU being monitored by this
test point."
::= { rbnCpuTempSensorEntry 2 }
rbnCpuTempCurrent OBJECT-TYPE
SYNTAX RbnTemperature
UNITS "degrees"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current temperature of this CPU."
::= { rbnCpuTempSensorEntry 3 }
rbnFanSpeedTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan unit within a fan
test point."
::= { rbnEnvMonMIBObjects 5 }
rbnFanSpeedEntry OBJECT-TYPE
SYNTAX RbnFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan unit within a fan
test point."
INDEX { rbnFanIndex, rbnFanUnitID }
::= { rbnFanSpeedTable 1 }
RbnFanSpeedEntry ::= SEQUENCE {
rbnFanUnitID Integer32,
rbnFanUnitDescr DisplayString,
rbnFanSpeedCurrent RbnFanSpeed
}
rbnFanUnitID OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the fan identification number that describes the
specific location of the fan unit within a fan test point."
::= { rbnFanSpeedEntry 1 }
rbnFanUnitDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the fan unit within a fan test point."
::= { rbnFanSpeedEntry 2 }
rbnFanSpeedCurrent OBJECT-TYPE
SYNTAX RbnFanSpeed
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed of this fan unit."
::= { rbnFanSpeedEntry 3 }
rbnEntityTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per temperature
sensor on the physical entity."
::= { rbnEnvMonMIBObjects 6 }
rbnEntityTempSensorEntry OBJECT-TYPE
SYNTAX RbnEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular temperature test
point."
INDEX { entPhysicalIndex, rbnEntityTempIndex }
::= { rbnEntityTempSensorTable 1 }
RbnEntityTempSensorEntry ::= SEQUENCE {
rbnEntityTempIndex Integer32,
rbnEntityTempDescr DisplayString,
rbnEntityTempCurrent RbnTemperature
}
rbnEntityTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
particular physical entity. Index values are
not necessarily contiguous."
::= { rbnEntityTempSensorEntry 1 }
rbnEntityTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
being monitored by this test point."
::= { rbnEntityTempSensorEntry 2 }
rbnEntityTempCurrent OBJECT-TYPE
SYNTAX RbnTemperature
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature of this entity in degrees Celsius."
::= { rbnEntityTempSensorEntry 3 }
-- Notifications
rbnFanFailChange NOTIFICATION-TYPE
OBJECTS { rbnFanFail }
STATUS deprecated
DESCRIPTION
"A rbnFanFailChange notification signifies
that the value of an instance of rbnFanFail
has changed."
::= { rbnEnvMonMIBNotifications 1 }
rbnPowerFailChange NOTIFICATION-TYPE
OBJECTS { rbnPowerFail }
STATUS deprecated
DESCRIPTION
"A rbnPowerFailChange notification signifies
that the value of an instance of rbnPowerFail
has changed"
::= { rbnEnvMonMIBNotifications 2 }
rbnFanStatusChange NOTIFICATION-TYPE
OBJECTS { rbnFanStatus }
STATUS current
DESCRIPTION
"A rbnFanStatusChange notification signifies
that the value of an instance of rbnFanStatus
has changed."
::= { rbnEnvMonMIBNotifications 3 }
rbnPowerStatusChange NOTIFICATION-TYPE
OBJECTS { rbnPowerStatus }
STATUS current
DESCRIPTION
"A rbnPowerStatusChange notification signifies
that the value of an instance of rbnPowerStatus
has changed"
::= { rbnEnvMonMIBNotifications 4 }
-- Conformance Statements
rbnEnvMonMIBGroups OBJECT IDENTIFIER
::= { rbnEnvMonMIBConformance 1 }
rbnEnvMonMIBCompliances OBJECT IDENTIFIER
::= { rbnEnvMonMIBConformance 2 }
rbnEnvMonMIBObjectGroup OBJECT-GROUP
OBJECTS { rbnFanDescr, rbnFanFail,
rbnPowerDescr, rbnPowerFail
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { rbnEnvMonMIBGroups 1 }
rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { rbnFanFailChange,
rbnPowerFailChange
}
STATUS deprecated
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { rbnEnvMonMIBGroups 2 }
rbnEnvMonVoltageObjectGroup OBJECT-GROUP
OBJECTS { rbnVoltageDescr, rbnVoltageDesired,
rbnVoltageCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing voltage
environmental monitor information."
::= { rbnEnvMonMIBGroups 3 }
rbnEnvMonTempObjectGroup OBJECT-GROUP
OBJECTS { rbnCpuTempDescr, rbnCpuTempCurrent
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing temperature
environmental monitor information."
::= { rbnEnvMonMIBGroups 4 }
rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP
OBJECTS { rbnFanDescr, rbnFanStatus,
rbnPowerDescr, rbnPowerStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { rbnEnvMonMIBGroups 5 }
rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
NOTIFICATIONS { rbnFanStatusChange,
rbnPowerStatusChange
}
STATUS current
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { rbnEnvMonMIBGroups 6 }
rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP
OBJECTS { rbnFanUnitDescr, rbnFanSpeedCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { rbnEnvMonMIBGroups 7 }
rbnEnvMonEntityObjectGroup OBJECT-GROUP
OBJECTS { rbnEntityTempDescr, rbnEntityTempCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { rbnEnvMonMIBGroups 8 }
rbnEnvMonMIBCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
::= { rbnEnvMonMIBCompliances 1 }
rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { rbnEnvMonMIBCompliances 2 }
rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { rbnEnvMonMIBCompliances 3 }
rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
GROUP rbnEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
::= { rbnEnvMonMIBCompliances 4 }
rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP rbnEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP rbnEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP rbnEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
GROUP rbnEnvMonEntityObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities, also applicable to SSE
card and disks"
::= { rbnEnvMonMIBCompliances 5 }
END