mibs/MIBS/ericsson/RBN-TC

165 lines
5.0 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- %DNP% $Id: RBN-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/RBN-TC.my,v $
-- *****************************************************************
-- RBN-TC Textual Convention MIB
--
-- Copyright (c) 2000, 2002-2009, 2011 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
RBN-TC DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
Integer32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
rbnModules
FROM RBN-SMI;
rbnTC MODULE-IDENTITY
LAST-UPDATED "201101191800Z" -- Jan 19, 2011
ORGANIZATION "Ericsson AB."
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"Defines common textual conventions used in RBN mib
modules."
REVISION "201101191800Z" -- Jan 19, 2011
DESCRIPTION
"Update CONTACT-INFO & ORGANIZATION. "
REVISION "200910201700Z" -- Oct 20, 2009
DESCRIPTION
"Added new textual convention: RbnUnsigned64 for read-write
capable 64 bit integer value."
REVISION "200406191700Z" -- June 19, 2004
DESCRIPTION
"Added new textual convention: RbnPortMediumType. Correct
warnings given by smilint."
REVISION "200303171700Z" -- March 17, 2003
DESCRIPTION
"Added new textual convention: RbnVidOrUntagged."
REVISION "200211110000Z" -- November 11, 2002
DESCRIPTION
"Moved definitions of RbnSlot and RbnPort from RBN-PVC-MIB.
Updated range on RbnSlot and RbnPort."
REVISION "200206260000Z" -- June 26, 2002
DESCRIPTION
"Updated CONTACT-INFO. Added new textual conventions:
RbnKBytes and RbnPercentage."
REVISION "200007140000Z" -- July 14, 2000
DESCRIPTION
"Initial version."
::= { rbnModules 2 }
RbnCircuitHandle ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1d:1d:2x-2x-2x"
STATUS current
DESCRIPTION
"A unique identifier for individual circuits. The string is
composed of the following:
Octet 1 slot
2 port
3-8 circuit identifier
slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
0..n but SE CLI numbers slots/ports 1..n. For example: When the
SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
slot/port 0/1
"
SYNTAX OCTET STRING (SIZE (8))
RbnKBytes ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Storage size, expressed in units of 1024 bytes."
SYNTAX Integer32 (0..2147483647)
RbnPercentage ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d%"
STATUS current
DESCRIPTION
"This Textual Convention describes an object that stores
a whole integer percentage value."
SYNTAX Integer32 (0..100)
RbnSlot ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The chassis slot number. This is the physical slot
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE."
SYNTAX Unsigned32 (0..255)
RbnPort ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The chassis port number. This is the physical port
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE."
SYNTAX Unsigned32 (0..255)
RbnVidOrUntagged ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The twelve-bit VLAN Identifer (VID) used to uniquely
identify the VLAN to which the frame belongs. The VID is
encoded as an unsigned binary number. An untagged frame
does not carry any identification of the VLAN to which it
belongs and is designated with a value of 4096."
SYNTAX Integer32 (1..4096)
RbnPortMediumType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Medium type of NAS port."
SYNTAX INTEGER {
unknown(0),
dsl(11),
cable(12),
wireless(13),
satellite(14)
}
RbnUnsigned64 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "8d"
STATUS current
DESCRIPTION
"Unsigned 64 bit integer value is represented as an
OCTET STRING. This allows an unsigned integer value in
the range 0..18446744073709551615.
The octets are ordered with the first octet containing
the highest ordered bits of the integer and the 8th octet
containing the lowest ordered bits, corresponding to
network byte order."
SYNTAX OCTET STRING (SIZE(8))
END