mibs/MIBS/extreme/HA-MIB

409 lines
10 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- MIB File: HA.mib
HA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress
FROM SNMPv2-SMI
fibrechannel FROM Brocade-REG-MIB
swID, swSsn FROM SYSTEM-MIB
entPhysicalIndex, entPhysicalName FROM ENTITY-MIB
DisplayString
FROM SNMPv2-TC;
haMIB MODULE-IDENTITY
LAST-UPDATED "201805291200Z" -- May 29, 2018 12:00pm
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO
"Postal: Extreme Networks, Inc.
6480 Via Del Oro
San Jose, CA 95119 USA
Phone: +1 408 579-2800
E-mail: support@extremenetworks.com
WWW: http://www.extremenetworks.com"
DESCRIPTION
"The MIB module High Availability MIB.
Copyright (c) 2018 Extreme Networks, Inc.
All rights reserved."
REVISION "201805291200Z" -- May 29, 2018 12:00pm
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO with Extreme Networks"
REVISION "200208160000Z" -- Aug. 16, 2002
DESCRIPTION
"The initial revision for the High Availability MIB."
REVISION "200402251530Z" -- Feb 25, 2004 5:30pm
DESCRIPTION
"Added mib objects fruSupplierId, fruSupplierPartNum,
fruSupplierSerialNum and fruSupplierRevCode to fruTable."
REVISION "200902090000Z" -- Feb 9th, 2009
DESCRIPTION
"Added new value coreblade and ap blade for fru table."
REVISION "200904060000Z" -- Apr 6th, 2009
DESCRIPTION
"Added textual convention for FruClass."
REVISION "200906251200Z" -- Jun 25, 2009 12:00pm
DESCRIPTION "Removed the version information from Brocade's proprietary MIB file name."
REVISION "201007221000Z" -- Jul 22, 2010 10:00am
DESCRIPTION "Added frutype and frunum to the existing frustatuschange trap."
REVISION "201202061130Z" -- Feb 6, 2012 11:30am
DESCRIPTION "Changed all CP terms in the description as control card."
::= { fibrechannel 2 }
highAvailability OBJECT IDENTIFIER ::= { haMIB 1 }
haStatus OBJECT-TYPE
SYNTAX INTEGER
{
redundant (0),
nonredundant (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the system is redundant or not."
::= { highAvailability 1 }
FruClass ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The type of the FRU object."
SYNTAX INTEGER {
other(1),
unknown(2),
chassis (3),
cp (4),
other-CP(5),
switchblade (6),
wwn (7),
powerSupply(8),
fan(9),
coreblade(10),
applicationblade(11)
}
fruTable OBJECT-TYPE
SYNTAX SEQUENCE OF FRUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table inventories the field replaceable units (FRUs)
slots available. There is entry in this table for each entry
in the entPhysicalTable that has entPhysicalClass set to
'Container (5)' and has a child entry having entPhysicalIsFRU
field to be true"
::= {highAvailability 5}
fRUEntry OBJECT-TYPE
SYNTAX FRUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for FRU slot in the fruTable"
INDEX { entPhysicalIndex }
::= {fruTable 1}
FRUEntry ::= SEQUENCE {
fruClass FruClass,
fruStatus INTEGER,
fruObjectNum Integer32,
fruSupplierId DisplayString,
fruSupplierPartNum DisplayString,
fruSupplierSerialNum DisplayString,
fruSupplierRevCode DisplayString,
fruPowerConsumption DisplayString
}
fruClass OBJECT-TYPE
SYNTAX FruClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the FRU object that these slot can hold"
::= { fRUEntry 1 }
fruStatus OBJECT-TYPE
SYNTAX INTEGER {
other (1),
unknown (2),
on (3),
off (4),
faulty (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the FRU object in the slot"
::= {fRUEntry 2}
fruObjectNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the slot number of the blade and unit number for
everything else"
::= { fRUEntry 3 }
fruSupplierId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supplier id."
::= { fRUEntry 4 }
fruSupplierPartNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supplier part number."
::= { fRUEntry 5 }
fruSupplierSerialNum OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supplier serial number."
::= { fRUEntry 6 }
fruSupplierRevCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The supplier revision code."
::= { fRUEntry 7 }
fruPowerConsumption OBJECT-TYPE
SYNTAX DisplayString
UNITS "watt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This represents power consumption of blades.
This will have values only for core/switch blades
and for other FRUs, it will be 0"
::= { fRUEntry 8 }
fruHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF FruHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table gives the contents of the entire history
log of the FRU events"
::= {highAvailability 6}
fruHistoryEntry OBJECT-TYPE
SYNTAX FruHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a particular FRU event"
INDEX { fruHistoryIndex }
::= {fruHistoryTable 1}
FruHistoryEntry ::= SEQUENCE {
fruHistoryIndex Integer32,
fruHistoryClass FruClass,
fruHistoryObjectNum Integer32,
fruHistoryEvent INTEGER,
fruHistoryTime DisplayString,
fruHistoryFactoryPartNum DisplayString,
fruHistoryFactorySerialNum DisplayString
}
fruHistoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the FRU event in the history table"
::= {fruHistoryEntry 1}
fruHistoryClass OBJECT-TYPE
SYNTAX FruClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the FRU object related to the event"
::= { fruHistoryEntry 2 }
fruHistoryObjectNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the slot number of the blade and unit number for
everything else"
::= { fruHistoryEntry 3 }
fruHistoryEvent OBJECT-TYPE
SYNTAX
INTEGER {
added (1),
removed (2),
invalid (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the FRU event"
::= { fruHistoryEntry 4}
fruHistoryTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the time at which this event happened"
::= { fruHistoryEntry 5 }
fruHistoryFactoryPartNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the factory part num of the FRU object"
::= { fruHistoryEntry 6 }
fruHistoryFactorySerialNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the factory serial num of the FRU object"
::= { fruHistoryEntry 7 }
--
-- Control Processor (aka MM) table
--
cpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all the control cards in the system"
::= {highAvailability 7}
cpEntry OBJECT-TYPE
SYNTAX CPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry represents a single control card in the system"
INDEX { entPhysicalIndex }
::= {cpTable 1}
CPEntry ::= SEQUENCE {
cpStatus INTEGER,
cpIpAddress IpAddress,
cpIpMask IpAddress,
cpIpGateway IpAddress,
cpLastEvent INTEGER
}
cpStatus OBJECT-TYPE
SYNTAX INTEGER {
other (1),
unknown (2),
active (3),
standby (4), -- Ready to takeover
failed (5) -- Not ready to takeover
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the control card"
::= { cpEntry 1 }
cpIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of the Ethernet interface of this control card."
::= { cpEntry 2 }
cpIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Mask of the Ethernet interface of this control card."
::= { cpEntry 3 }
cpIpGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of the IP Gateway for this control card."
::= { cpEntry 4 }
cpLastEvent OBJECT-TYPE
SYNTAX INTEGER {
other (1),
unknown (2),
haSync (3),
haOutSync (4),
cpFaulty (5),
cpHealthy (6),
cpActive (7),
configChange (8),
failOverStart (9),
failOverDone (10),
firmwareCommit (11),
firmwareUpgrade (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last event related to this control card"
::= { cpEntry 5 }
--
-- Blade Processor (aka LC) table
--
--
-- Notifications
--
haMIBTraps OBJECT IDENTIFIER ::= { haMIB 2 }
haMIBTrapPrefix OBJECT IDENTIFIER ::= { haMIBTraps 0 }
fruStatusChanged NOTIFICATION-TYPE
OBJECTS { entPhysicalName, fruStatus, fruClass, fruObjectNum}
STATUS current
DESCRIPTION
"This trap is sent when status of any FRU object is changed"
::= { haMIBTrapPrefix 1 }
cpStatusChanged NOTIFICATION-TYPE
OBJECTS { cpStatus, cpLastEvent, swID, swSsn}
STATUS current
DESCRIPTION
"This trap is sent when status of any control card object is changed"
::= { haMIBTrapPrefix 2 }
fruHistoryTrap NOTIFICATION-TYPE
OBJECTS { fruHistoryClass, fruHistoryObjectNum,
fruHistoryEvent, fruHistoryTime, fruHistoryFactoryPartNum,
fruHistoryFactorySerialNum }
STATUS current
DESCRIPTION
"This trap is sent when a FRU is added or removed"
::= { haMIBTrapPrefix 3 }