mibs/MIBS/fs/GBNDeviceSwitch-MIB

2797 lines
102 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
GBNDeviceSwitch-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, IpAddress,
NOTIFICATION-TYPE FROM SNMPv2-SMI
DisplayString, MacAddress,
RowStatus, TruthValue,DateAndTime FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
gbnDevice FROM ADMIN-MASTER-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
VlanIndex FROM Q-BRIDGE-MIB
PortList, dot1qStaticMulticastEntry FROM Q-BRIDGE-MIB;
gbnDeviceSwitch MODULE-IDENTITY
LAST-UPDATED "0011020000Z" -- November 2, 2000
ORGANIZATION "Admin Co., Ltd."
CONTACT-INFO "Admin Co., Ltd.
E-mail: support@admin.com"
DESCRIPTION "ADMIN Common Enterprise MIB definition."
REVISION "0011020000Z" -- November 2, 2000
DESCRIPTION "Initial MIB creation."
::= { gbnDevice 1 }
MirrorMacType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"null<6C><6C>destination<6F><6E>source"
SYNTAX INTEGER { null(0), destination (1), source(2) }
------------------------------------------------------------------------------
-- define groups in gbnDeviceSwitch-MIB
------------------------------------------------------------------------------
gbnDeviceSwitchMirror OBJECT IDENTIFIER ::= { gbnDeviceSwitch 1 }
gbnDeviceSwitchPort OBJECT IDENTIFIER ::= { gbnDeviceSwitch 2 }
gbnDeviceSwitchAggregation OBJECT IDENTIFIER ::= { gbnDeviceSwitch 3 }
gbnDeviceSwitchL3 OBJECT IDENTIFIER ::= { gbnDeviceSwitch 4 }
gbnDeviceSwitchLoopTest OBJECT IDENTIFIER ::= { gbnDeviceSwitch 5 }
gbnDeviceSwitchSRM OBJECT IDENTIFIER ::= { gbnDeviceSwitch 6 }
gbnDeviceSwitchFlowAlarm OBJECT IDENTIFIER ::= { gbnDeviceSwitch 7 }
gbnDeviceSwitchQueneScheduer OBJECT IDENTIFIER ::= { gbnDeviceSwitch 8 }
gbnDeviceSwitchLineRate OBJECT IDENTIFIER ::= { gbnDeviceSwitch 9 }
gbnDeviceSwitchPortIsolation OBJECT IDENTIFIER ::= { gbnDeviceSwitch 10 }
gbnDeviceSwitchStormControl OBJECT IDENTIFIER ::= { gbnDeviceSwitch 11 }
gbnDeviceSwitchAntiDos OBJECT IDENTIFIER ::= { gbnDeviceSwitch 12 }
gbnDeviceSwitchBandWidth OBJECT IDENTIFIER ::= { gbnDeviceSwitch 13 }
gbnDeviceSwitchHigigStatistics OBJECT IDENTIFIER ::= { gbnDeviceSwitch 14 }
gbnDeviceSwitchChannelStats OBJECT IDENTIFIER ::= { gbnDeviceSwitch 15 }
gbnDeviceSwitchRmoteMirror OBJECT IDENTIFIER ::= { gbnDeviceSwitch 16 }
gbnDeviceSwitchPortSFPInfo OBJECT IDENTIFIER ::= { gbnDeviceSwitch 17 }
gbnDeviceSwitchPortAvgRate OBJECT IDENTIFIER ::= { gbnDeviceSwitch 18 }
gbnDeviceSwitchPortbandwidthUtilization OBJECT IDENTIFIER ::= { gbnDeviceSwitch 19 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchMirror - Mirror Group
--
------------------------------------------------------------------------------
mirroringPort OBJECT-TYPE
SYNTAX INTEGER (0..26)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This port which all packets send to."
::= { gbnDeviceSwitchMirror 1 }
mirroredEgrPort OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The egress ports which need to monitor."
::= { gbnDeviceSwitchMirror 2 }
mirroredIgrPort OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ingress ports which need to monitor."
::= { gbnDeviceSwitchMirror 3 }
ingressMirrorMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address which will be compared with the ingress frame, Only the matched frame will be mirrored"
--<2D><><EFBFBD><EFBFBD>ƥ<EFBFBD><C6A5>ingress<73><73><EFBFBD>ĵ<EFBFBD>MAC<41><43>ַ
::= { gbnDeviceSwitchMirror 4 }
egressMirrorMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address which will be compared with the egress frame, Only the matched frame will be mirrored"
--<2D><><EFBFBD><EFBFBD>ƥ<EFBFBD><C6A5>egress<73><73><EFBFBD>ĵ<EFBFBD>MAC<41><43>ַ
::= { gbnDeviceSwitchMirror 5 }
ingressMirrorMacType OBJECT-TYPE
SYNTAX MirrorMacType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination or source MAC address which will be compared with the ingress frame"
--ָ<><D6B8><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ƥ<EFBFBD><C6A5>ingress<73><73><EFBFBD>ĵ<EFBFBD><C4B5><EFBFBD>Ŀ<EFBFBD>Ļ<EFBFBD><C4BB><EFBFBD>ԴMAC<41><43>ַ
::= { gbnDeviceSwitchMirror 6 }
egressMirrorMacType OBJECT-TYPE
SYNTAX MirrorMacType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination or source MAC address which will be compared with the egress frame"
--ָ<><D6B8><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ƥ<EFBFBD><C6A5>egress<73><73><EFBFBD>ĵ<EFBFBD><C4B5><EFBFBD>Ŀ<EFBFBD>Ļ<EFBFBD><C4BB><EFBFBD>ԴMAC<41><43>ַ
::= { gbnDeviceSwitchMirror 7 }
ingressMirrorDivider OBJECT-TYPE
SYNTAX INTEGER(0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the mirror sampling divider"
--ingress<73><73><EFBFBD>ĵIJ<C4B5><C4B2><EFBFBD>ֵ
::= { gbnDeviceSwitchMirror 8 }
egressMirrorDivider OBJECT-TYPE
SYNTAX INTEGER(0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the mirror sampling divider"
--egress<73><73><EFBFBD>ĵIJ<C4B5><C4B2><EFBFBD>ֵ
::= { gbnDeviceSwitchMirror 9 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchPort - Port Group
--
------------------------------------------------------------------------------
portTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch interfaces and associated properties."
::= { gbnDeviceSwitchPort 1 }
portTypeEntry OBJECT-TYPE
SYNTAX PortTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for switch interface control and status information."
INDEX { portNumber }
::= { portTypeTable 1 }
PortTypeEntry ::= SEQUENCE {
portNumber INTEGER,
portType INTEGER
}
portNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the index of port."
::= { portTypeEntry 1 }
portType OBJECT-TYPE
SYNTAX INTEGER {
blank(1),
FE(2),
single100FX(3),
double100FX(4),
single1000FX(5),
double1000FX(6),
fE1000(7),
cpu(8),
FX10000(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"<22>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD>:1Ϊ<31><CEAA><EFBFBD><EFBFBD><EFBFBD>ڣ<EFBFBD>2Ϊ10/100M<30><4D><EFBFBD>ڣ<EFBFBD>3Ϊ100M<30><4D>ģ<EFBFBD><C4A3><EFBFBD>ڣ<EFBFBD>
4Ϊ100M<30><4D>ģ<EFBFBD><C4A3><EFBFBD>ڣ<EFBFBD>5Ϊ1000M<30><4D><EFBFBD>ڣ<EFBFBD>6Ϊ1000M<30><4D><EFBFBD>ڣ<EFBFBD>
7Ϊ1000M<30><4D><EFBFBD><EFBFBD>; 8ΪCPU<50>ӿ<EFBFBD>;9Ϊ10000M<30><4D><EFBFBD><EFBFBD>"
::= { portTypeEntry 2 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchAggregation - Port Trunk Group
--
------------------------------------------------------------------------------
aggTable OBJECT-TYPE
SYNTAX SEQUENCE OF AggEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"A table that contains information about every
Aggregator that is associated with this System."
::= { gbnDeviceSwitchAggregation 1 }
aggEntry OBJECT-TYPE
SYNTAX AggEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"A list of the Aggregator parameters. This is indexed
by the ifIndex of the Aggregator."
INDEX { aggUnit, aggPort }
::= { aggTable 1 }
AggEntry ::=
SEQUENCE {
aggUnit
INTEGER,
aggPort
INTEGER,
aggPortListPorts
PortList,
aggRule
INTEGER,
aggRowstatus
RowStatus
}
aggUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The Interface Unit of the Aggregation."
::= { aggEntry 1 }
aggPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The MasterPort of the Aggregation."
::= { aggEntry 2 }
aggPortListPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The complete set of ports currently associated with
this Aggregator. Each bit set in this list represents
an Actor Port member of this Link Aggregation."
::= { aggEntry 3 }
aggRule OBJECT-TYPE
SYNTAX INTEGER {
srcMAC(1),
destMAC(2),
srcXORDestMAC(3),
srcIP(4),
destIP(5),
srcXORDestIP(6)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION
" The Rule to be applied to this Link Aggregator's Trunk Group
Table. The rules are based on the following selections SrcMAC (1),
means that the last three bits of the Source MAC Address are used to
index the Trunk Group to get the destination port. DestMAC (2), means
the last three bits of the Destination MAC Address are used to index
into the Trunk Group to get the destination port. SrcXORDestMAC (3),
means that the last three bits of the Source MAC Address are logically
XORed with the last three bits of the Destination MAC Address and used
to index into the Trunk Group to get the destination port. SrcIP (4),
means the last three bits of the Source IP Address are used to index
into the Trunk Group to get the destination port. DestIP (5), means
the last three bits of the Destination IP Address are used to index
into the Trunk Group to get the destination port. SrcXORDestIP (6),
means the last three bits of the Source IP Address are logically XORed
with the last three bits of the Destination IP Address and used to
index into the Trunk Group to get the destination port. This rule
defines the distribution algorithm applied to the aggregated link."
::= { aggEntry 4 }
aggRowstatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"rowstatus of trunk."
::= { aggEntry 5 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchL3 - L3 Group
--
------------------------------------------------------------------------------
l3Table OBJECT-TYPE
SYNTAX SEQUENCE OF L3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "<22>˱<EFBFBD>Ϊ<EFBFBD><CEAA><EFBFBD><EFBFBD>оƬ<D0BE><C6AC>L3<4C><33><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ݡ<EFBFBD>"
::= { gbnDeviceSwitchL3 1 }
l3Entry OBJECT-TYPE
SYNTAX L3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "<22><><EFBFBD><EFBFBD>оƬ<D0BE><C6AC>L3<4C><33><EFBFBD><EFBFBD>˱<EFBFBD>Ϊֻ<CEAA><D6BB><EFBFBD><EFBFBD>"
INDEX { l3IpAddress }
::= { l3Table 1 }
L3Entry ::=
SEQUENCE {
l3IpAddress IpAddress,
l3NextHopMacAddress MacAddress,
l3Vlan VlanIndex,
l3Port INTEGER,
l3CreateTime DateAndTime,
l3UpdateTime DateAndTime
}
l3IpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ŀ<><C4BF>IP<49><50>ַ<EFBFBD><D6B7><EFBFBD><EFBFBD>Ϊ<EFBFBD><CEAA><EFBFBD><EFBFBD><EFBFBD><EFBFBD>"
::= { l3Entry 1 }
l3NextHopMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "<22><>һ<EFBFBD><D2BB>IP<49><50>MAC<41><43>ַ<EFBFBD><D6B7>"
::= { l3Entry 2 }
l3Vlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "<22><>һ<EFBFBD><D2BB>IP<49><50><EFBFBD>ڵ<EFBFBD>VLAN<41><4E>"
::= { l3Entry 3 }
l3Port OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "<22><><EFBFBD>ĵij<C4B5><C4B3>˿ڡ<CBBF>"
::= { l3Entry 4 }
l3CreateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Create Time,such as 2004-07-29,13:30:15.0"
::= { l3Entry 5 }
l3UpdateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Update Time,such as 2004-07-29,13:30:15.0"
::= { l3Entry 6 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchLoopTest - Loop Test Group
--
------------------------------------------------------------------------------
loopTestPortno OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"port bitmap:Numbers of the port to be tested.
The highest bit is port 1, the second bit is port 2, and so on."
::= { gbnDeviceSwitchLoopTest 1 }
loopTestType OBJECT-TYPE
SYNTAX INTEGER {
noop(1), -- no operation
local(2), -- for both vdsl and ethernet port
remote(3), -- for both vdsl and ethernet port
other(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { 4 }
Setting this object to 2-4 enables loop back test.
Setting it to 1 disables loop back test."
::= { gbnDeviceSwitchLoopTest 2 }
loopTestSuccess OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"if the highest bit is
0:the port 1 loop fail,
1,the port 1 loop success,
and so on.
"
::= { gbnDeviceSwitchLoopTest 3 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchSRM - SRM Group
--
------------------------------------------------------------------------------
srmHardwareEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Add network routes to hardware table or not.Default is enable."
-- "<22>Ƿ<EFBFBD><C7B7>·<EFBFBD><C2B7><EFBFBD><EFBFBD><EFBFBD>·<EFBFBD>ɵ<EFBFBD>Ӳ<EFBFBD><D3B2><EFBFBD><EFBFBD><EFBFBD>С<EFBFBD>Ĭ<EFBFBD><C4AC>Ϊ<EFBFBD>·<EFBFBD><C2B7><EFBFBD>"
::= { gbnDeviceSwitchSRM 1 }
srmHardwareDEFCPU OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The DEF routes goes to CPU."
-- "Ӳ<><D3B2><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʧ<EFBFBD>ܵ<EFBFBD>·<EFBFBD>ɷ<EFBFBD><C9B7>͵<EFBFBD>CPU<50><55><EFBFBD>˹<EFBFBD><CBB9><EFBFBD>ֻ<EFBFBD><D6BB>TiNet S3750֧<30>֣<EFBFBD>Ĭ<EFBFBD><C4AC>Ϊdisable"
::= { gbnDeviceSwitchSRM 2 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchFlowAlarm - Port Flow Alarm Group
--
------------------------------------------------------------------------------
portFlowAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortFlowAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Table of port flow alarm."
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><E6BEAF>
::= { gbnDeviceSwitchFlowAlarm 1 }
portFlowAlarmEntry OBJECT-TYPE
SYNTAX PortFlowAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port flow alarm."
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>б<EFBFBD>
INDEX { portFlowAlarmPort }
::= { portFlowAlarmTable 1 }
PortFlowAlarmEntry ::= SEQUENCE {
portFlowAlarmPort Integer32,
portFlowAlarmEnable TruthValue,
portFlowAlarmExceedStatus TruthValue,
portFlowAlarmExceedThreshold Integer32,
portFlowAlarmNormalThreshold Integer32
}
portFlowAlarmPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number."
--<2D>˿ںţ<DABA><C5A3>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><E6BEAF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ֵ
::= { portFlowAlarmEntry 1 }
portFlowAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The enable status of the port flow alarm"
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><E6BEAF><EFBFBD><EFBFBD>/<2F>ر<EFBFBD>״̬
::= { portFlowAlarmEntry 2 }
portFlowAlarmExceedStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The exceed status of the port flow alarm"
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><E6BEAF><EFBFBD><EFBFBD>״̬
::= { portFlowAlarmEntry 3 }
portFlowAlarmExceedThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The exceed threshold of port flow alarm."
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ֵ
::= { portFlowAlarmEntry 4 }
portFlowAlarmNormalThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The normal threshold of port flow alarm."
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ֵ
::= { portFlowAlarmEntry 5 }
portFlowAlarmGlobalEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The global enable status of port flow alarm."
--ȫ<>ֶ˿<D6B6><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><E6BEAF><EFBFBD><EFBFBD>/<2F>ر<EFBFBD>״̬
::= { gbnDeviceSwitchFlowAlarm 2 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchTrap - gbn device switch TRAP
--
------------------------------------------------------------------------------
portFlowAlarmTrap OBJECT IDENTIFIER ::= { gbnDeviceSwitchFlowAlarm 5 }
portFlowAlarmExceedTrap NOTIFICATION-TYPE
OBJECTS { portFlowAlarmPort }
STATUS current
DESCRIPTION
"Port ingress packet rate become too big, port flow exceed alarm happen."
::= { portFlowAlarmTrap 1 }
portFlowAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { portFlowAlarmPort }
STATUS current
DESCRIPTION
"Port ingress packet rate become normal, port flow normal alarm happen."
--<2D><><EFBFBD><EFBFBD><EFBFBD>˿ڽ<CBBF><DABD><EFBFBD><EFBFBD>ı<EFBFBD><C4B1><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʻָ<CABB><D6B8><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>򷢳<EFBFBD><F2B7A2B3>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>trap
::= { portFlowAlarmTrap 2 }
-- the quene-scheduer QOS
qosQueueSchedulerGroup OBJECT IDENTIFIER ::= { gbnDeviceSwitchQueneScheduer 1 }
qosWrrQueue1Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 1th queue(%). for 3650, the range is 1 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>1<EFBFBD><31>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 1 }
qosWrrQueue2Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 2th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>2<EFBFBD><32>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 2 }
qosWrrQueue3Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 3th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>3<EFBFBD><33>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 3 }
qosWrrQueue4Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 4th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>4<EFBFBD><34>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 4 }
qosWrrMaxDelayValue OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS current
DESCRIPTION
"the maximum allowable latency for packet transmission on the priorest COS"
--<2D><><EFBFBD>е<EFBFBD><D0B5><EFBFBD>ʱ<EFBFBD><CAB1><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ȼ<EFBFBD><C8BC>Ķ<EFBFBD><C4B6><EFBFBD><EFBFBD><EFBFBD>ȴ<EFBFBD>ʱ<EFBFBD><CAB1>
::= { qosQueueSchedulerGroup 5 }
qosQueueSchedulerMode OBJECT-TYPE
SYNTAX INTEGER {
strictPriority (1),
wrr(2),
sp-wrr(3) }
ACCESS read-write
STATUS current
DESCRIPTION
"queue scheduler mode: strict priority, weighted round robin, strict priority+weighted round robin"
--<2D><><EFBFBD>е<EFBFBD><D0B5><EFBFBD>ģʽ:<3A><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ȼ<EFBFBD><C8BC><EFBFBD><EFBFBD><EFBFBD>Ȩ<EFBFBD><C8A8>ѭ<EFBFBD><D1AD><EFBFBD><EFBFBD>
DEFVAL { strictPriority }
::= { qosQueueSchedulerGroup 6 }
qosWrrQueue5Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 5th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>5<EFBFBD><35>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 7 }
qosWrrQueue6Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 6th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>6<EFBFBD><36>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 8 }
qosWrrQueue7Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 7th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>7<EFBFBD><37>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 9 }
qosWrrQueue8Weight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"Weight of 8th queue(%). for 3650, the range is 0 to 255, for 3750-24/48,the range is 1 to 15."
--<2D><><EFBFBD><EFBFBD>8<EFBFBD><38>Ȩ<EFBFBD>ء<EFBFBD><D8A1><EFBFBD><EFBFBD><EFBFBD>3650<35><30><EFBFBD><EFBFBD>ΧΪ0<CEAA><30>255<35><35><EFBFBD><EFBFBD><EFBFBD><EFBFBD>3750-24/48<34><38><EFBFBD><EFBFBD>ΧΪ1<CEAA><31>15
::= { qosQueueSchedulerGroup 10 }
qosLineRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosLineRateEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of line-rate QOS entries. "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ڱ<EFBFBD>
::= { gbnDeviceSwitchLineRate 1 }
qosLineRateEntry OBJECT-TYPE
SYNTAX QosLineRateEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of line-rate QOS entries. "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>
INDEX { qosLineRateInterface }
::= { qosLineRateTable 1 }
QosLineRateEntry ::=
SEQUENCE {
qosLineRateInterface
INTEGER,
qosLineRateTargetRate
INTEGER,
qosLineRateTargetBurst
INTEGER,
qosLineRateTargetRateIngress
INTEGER,
qosLineRateRowStatus
RowStatus
}
qosLineRateInterface OBJECT-TYPE
SYNTAX INTEGER (1..26)
ACCESS read-only
STATUS current
DESCRIPTION
"the line rate interface. "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD>ٶ˿<D9B6>
::= { qosLineRateEntry 1 }
qosLineRateTargetRate OBJECT-TYPE
SYNTAX INTEGER (64..1000000)
ACCESS read-write
STATUS current
DESCRIPTION
"The target rate(Kbps) of the line-rate QOS. Must be a multiple of 64Kbps "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD><EFBFBD>(Kbps),<2C><><EFBFBD><EFBFBD><EFBFBD><EFBFBD>64Kbps<70>ı<EFBFBD><C4B1><EFBFBD>
::= { qosLineRateEntry 2 }
qosLineRateTargetBurst OBJECT-TYPE
SYNTAX INTEGER (64..1000000)
ACCESS read-write
STATUS current
DESCRIPTION
"The target burst(Kbps) of the line-rate QOS. Must be a multiple of 64Kbps "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ͻ<EFBFBD><CDBB><EFBFBD><EFBFBD><EFBFBD><EFBFBD>(Kbps),<2C><><EFBFBD><EFBFBD><EFBFBD><EFBFBD>64Kbps<70>ı<EFBFBD><C4B1><EFBFBD>
::= { qosLineRateEntry 3 }
qosLineRateTargetRateIngress OBJECT-TYPE
SYNTAX INTEGER (0..1024000)
ACCESS read-write
STATUS current
DESCRIPTION
"The ingress target rate(Kbps) of the line-rate QOS.0 means disable"
--<2D><><EFBFBD>ڶ˿<DAB6><CBBF><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD><EFBFBD>(Kbps)
::= { qosLineRateEntry 4 }
portIsolationGroup OBJECT IDENTIFIER ::= { gbnDeviceSwitchPortIsolation 1 }
portIsolationDownLinkPorts OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS current
DESCRIPTION
"port isolation down link portlist"
-- <20>˿ڸ<CBBF><DAB8><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ж˿<D0B6><CBBF>б<EFBFBD> --
::= { portIsolationGroup 1 }
portIsolationUpLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortIsolationUpLinkEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of uplink-ports of portisolation entries. conflict with portIsolationDownLinkPorts."
--<2D><><EFBFBD>ڶ˿ڵĶ˿ڸ<CBBF><DAB8><EFBFBD><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>б<EFBFBD><D0B1><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ܹ<EFBFBD><DCB9><EFBFBD>portIsolationDownLinkPortsͬʱʹ<CAB1><CAB9>
::= { portIsolationGroup 2 }
portIsolationUpLinkEntry OBJECT-TYPE
SYNTAX PortIsolationUpLinkEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of uplink-ports of portisolation entries. "
--<2D><><EFBFBD>ڶ˿ڵĶ˿ڸ<CBBF><DAB8><EFBFBD><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>б<EFBFBD>
INDEX { portisolationInterface }
::= { portIsolationUpLinkTable 1 }
PortIsolationUpLinkEntry ::=
SEQUENCE {
portisolationInterface
INTEGER,
portisolationUplinkList
PortList
}
portisolationInterface OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"port index, start from 1. "
--<2D>˿<EFBFBD><CBBF><EFBFBD><EFBFBD><EFBFBD>
::= { portIsolationUpLinkEntry 1 }
portisolationUplinkList OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS current
DESCRIPTION
"portlist of uplink ports,when configured , a port can only communicate with it's uplink ports. "
--<2D><><EFBFBD>п<EFBFBD><D0BF>б<EFBFBD><D0B1><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ú󣬶˿<F3A3ACB6>ֻ<EFBFBD><D6BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD>ͨ<EFBFBD><CDA8>
::= { portIsolationUpLinkEntry 2 }
stormControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF StormControlEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of storm control entries. "
--<2D><EFBFBD><E7B1A9><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ڱ<EFBFBD>
::= { gbnDeviceSwitchStormControl 1 }
stormControlEntry OBJECT-TYPE
SYNTAX StormControlEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of storm control entries. "
--<2D><EFBFBD><E7B1A9><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>
INDEX { stormControlInterface, stormControlType }
::= { stormControlTable 1 }
StormControlEntry ::=
SEQUENCE {
stormControlInterface
INTEGER,
stormControlType
INTEGER,
stormControlTargetRate
INTEGER,
stormControlRowStatus
RowStatus,
stormControlMode
INTEGER
}
stormControlInterface OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"the storm control interface. "
--<2D><EFBFBD><E7B1A9><EFBFBD>ƶ˿<C6B6>
::= { stormControlEntry 1 }
stormControlType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
"the pack flow type of the storm control. "
--<2D><EFBFBD><E7B1A9><EFBFBD>Ʊ<EFBFBD><C6B1><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>
::= { stormControlEntry 2 }
stormControlTargetRate OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-write
STATUS current
DESCRIPTION
"the target rate of the storm control. "
--<2D><EFBFBD><E7B1A9><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD><EFBFBD>
::= { stormControlEntry 3 }
stormControlRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"row status of the storm control"
--<2D><EFBFBD><E7B1A9><EFBFBD><EFBFBD><EFBFBD><EFBFBD>״̬
::= { stormControlEntry 4 }
stormControlMode OBJECT-TYPE
SYNTAX INTEGER {
pps(0),
bps(1) }
ACCESS read-write
STATUS current
DESCRIPTION
"the mode of the storm control. "
::= { stormControlEntry 5 }
ipfragmnetnumber OBJECT-TYPE
SYNTAX INTEGER (0..800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ip fragment number."
::= { gbnDeviceSwitchAntiDos 1 }
ipTTL OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control IP with TTL=0 packet,default is not traffic to the CPU."
--<2D><><EFBFBD><EFBFBD>TTL=0<>ı<EFBFBD><C4B1><EFBFBD><EFBFBD>Ƿ<EFBFBD><C7B7><EFBFBD><EFBFBD><EFBFBD>CPU,Ĭ<><C4AC><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ǹر<C7B9><D8B1>ϱ<EFBFBD>CPU.
::= { gbnDeviceSwitchAntiDos 2 }
bandwidthcontrolTable OBJECT-TYPE
SYNTAX SEQUENCE OF BandwidthcontrolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch interfaces and associated properties."
::= { gbnDeviceSwitchBandWidth 1 }
bandwidthcontrolEntry OBJECT-TYPE
SYNTAX BandwidthcontrolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for switch interface control and status information."
INDEX { controlPort }
::= { bandwidthcontrolTable 1 }
BandwidthcontrolEntry ::= SEQUENCE {
controlPort INTEGER,
portEgressBandwidthcontrol INTEGER,
portIngressBandwidthcontrol INTEGER
}
controlPort OBJECT-TYPE
SYNTAX INTEGER (1..26)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the index of port."
::= { bandwidthcontrolEntry 1 }
portEgressBandwidthcontrol OBJECT-TYPE
SYNTAX INTEGER (0..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Egress Speed Value of port, bandwidth control ."
::= { bandwidthcontrolEntry 2 }
portIngressBandwidthcontrol OBJECT-TYPE
SYNTAX INTEGER (0..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ingress Speed Value of port, bandwidth control ."
::= { bandwidthcontrolEntry 3 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchHigigStatistics - Higig Statistics Info
--
------------------------------------------------------------------------------
higigStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HigigStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Higig Statistics Info."
::= { gbnDeviceSwitchHigigStatistics 1 }
higigStatisticsEntry OBJECT-TYPE
SYNTAX HigigStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for Higig Statistics information."
INDEX { unit , higig }
::= { higigStatisticsTable 1 }
HigigStatisticsEntry ::= SEQUENCE {
unit INTEGER,
higig INTEGER,
snEtherStatsPkts64Octets Counter64,
snEtherStatsPkts65to127Octets Counter64,
snEtherStatsPkts128to255Octets Counter64,
snEtherStatsPkts256to511Octets Counter64,
snEtherStatsPkts512to1023Octets Counter64,
snEtherStatsPkts1024to1518Octets Counter64,
sndot1dTpPortInFrames Counter64,
snifInOctets Counter64,
snifInDiscards Counter64,
snifInUcastPkts Counter64,
snifInMulticastPkts Counter64,
snifInBroadcastPkts Counter64,
snifInErrors Counter64,
snDot3StatsFCSErrors Counter64,
snDot3StatsSymbolErrors Counter64,
snDot3StatsCarrierSenseErrors Counter64,
snEtherStatsUndersizePkts Counter64,
snEtherStatsOversizePkts Counter64,
snEtherStatsFragments Counter64,
snEtherStatsJabbers Counter64,
sndot1dTpPortOutFrames Counter64,
snifOutOctets Counter64,
snifOutDiscards Counter64,
snifOutUcastPkts Counter64,
snifOutMulticastPkts Counter64,
snifOutBroadcastPkts Counter64,
snifOutErrors Counter64,
snDot3StatsDeferredTransmissions Counter64,
snEtherStatsCollisions Counter64,
snDot3StatsLateCollisions Counter64
}
unit OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"unit number."
::= { higigStatisticsEntry 1 }
higig OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"higig number."
::= { higigStatisticsEntry 2 }
snEtherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 3 }
snEtherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 4 }
snEtherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 5 }
snEtherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 6 }
snEtherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 7 }
snEtherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { higigStatisticsEntry 8 }
sndot1dTpPortInFrames OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { higigStatisticsEntry 9 }
snifInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the interface,
including framing characters.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 10 }
snifInDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets which were chosen to be
discarded even though no errors had been detected to
prevent their being deliverable to a higher-layer
protocol. One possible reason for discarding such a
packet could be to free up buffer space.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 11 }
snifInUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were not addressed to a
multicast or broadcast address at this sub-layer.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 12 }
snifInMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast address at this sub-layer. For a MAC layer
protocol, this includes both Group and Functional
addresses.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 13 }
snifInBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 14 }
snifInErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of inbound
packets that contained errors preventing them from
being deliverable to a higher-layer protocol. For
character-oriented or fixed-length interfaces, the
number of inbound transmission units that contained
errors preventing them from being deliverable to a
higher-layer protocol.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 15 }
snDot3StatsFCSErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of frames received on a particular
interface that are an integral number of octets
in length but do not pass the FCS check.
The count represented by an instance of this
object is incremented when the frameCheckError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
REFERENCE
"IEEE 802.3 Layer Management"
::= { higigStatisticsEntry 16 }
snDot3StatsSymbolErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For an interface operating at 100 Mb/s, the
number of times there was an invalid data symbol
when a valid carrier was present.
For an interface operating in half-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle (a carrier event) for a period
of time equal to or greater than slotTime, and
during which there was at least one occurrence
of an event that causes the PHY to indicate
'Data reception error' or 'carrier extend error'
on the GMII.
For an interface operating in full-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle a carrier event) for a period
of time equal to or greater than minFrameSize,
and during which there was at least one
occurrence of an event that causes the PHY to
indicate 'Data reception error' on the GMII.
The count represented by an instance of this
object is incremented at most once per carrier
event, even if multiple symbol errors occur
during the carrier event. This count does
not increment if a collision is present.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE
"[IEEE 802.3 Std.], 30.3.2.1.5,
aSymbolErrorDuringCarrier."
::= { higigStatisticsEntry 17 }
snDot3StatsCarrierSenseErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that the carrier sense
condition was lost or never asserted when
attempting to transmit a frame on a particular
interface.
The count represented by an instance of this
object is incremented at most once per
transmission attempt, even if the carrier sense
condition fluctuates during a transmission
attempt."
REFERENCE
"IEEE 802.3 Layer Management"
::= { higigStatisticsEntry 18 }
snEtherStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { higigStatisticsEntry 19 }
snEtherStatsOversizePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { higigStatisticsEntry 20 }
snEtherStatsFragments OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less
than 64 octets in length (excluding framing bits but
including FCS octets) and had either a bad Frame
Check Sequence (FCS) with an integral number of
octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Note that it is entirely normal for
etherStatsFragments to increment. This is because
it counts both runts (which are normal occurrences
due to collisions) and noise hits."
::= { higigStatisticsEntry 21 }
snEtherStatsJabbers OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { higigStatisticsEntry 22 }
sndot1dTpPortOutFrames OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been transmitted
by this port to its segment. Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { higigStatisticsEntry 23 }
snifOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
interface, including framing characters.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 24 }
snifOutDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets which were chosen to
be discarded even though no errors had been detected
to prevent their being transmitted. One possible
reason for discarding such a packet could be to free
up buffer space.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 25 }
snifOutUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were not
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 26 }
snifOutMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast address at this sub-layer,
including those that were discarded or not sent. For
a MAC layer protocol, this includes both Group and
Functional addresses.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 27 }
snifOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 28 }
snifOutErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of
outbound packets that could not be transmitted because
of errors. For character-oriented or fixed-length
interfaces, the number of outbound transmission units
that could not be transmitted because of errors.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { higigStatisticsEntry 29 }
snDot3StatsDeferredTransmissions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of frames for which the first
transmission attempt on a particular interface
is delayed because the medium is busy.
The count represented by an instance of this
object does not include frames involved in
collisions."
REFERENCE
"IEEE 802.3 Layer Management"
::= { higigStatisticsEntry 30 }
snEtherStatsCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment.
The value returned will depend on the location of
the RMON probe. Section 8.2.1.3 (10BASE-5) and
section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
states that a station must detect a collision, in
the receive mode, if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coax segments to which
the repeater is connected."
::= { higigStatisticsEntry 31 }
snDot3StatsLateCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that a collision is
detected on a particular interface later than
512 bit-times into the transmission of a
packet.
Five hundred and twelve bit-times corresponds
to 51.2 microseconds on a 10 Mbit/s system. A
(late) collision included in a count
represented by an instance of this object is
also considered as a (generic) collision for
purposes of other collision-related
statistics."
REFERENCE
"IEEE 802.3 Layer Management"
::= { higigStatisticsEntry 32 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchChannelStats - Channel group Sttatistics Info
--
------------------------------------------------------------------------------
channelStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Channel group Statistics Info(32)."
::= { gbnDeviceSwitchChannelStats 1 }
-- The channelStatsEntry
channelStatsEntry OBJECT-TYPE
SYNTAX ChannelStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for Channel Statistics information(32)."
INDEX { channelGroupIndex }
::= { channelStatsTable 1 }
ChannelStatsEntry ::= SEQUENCE {
channelGroupIndex INTEGER,
channelInOctetRate Counter32,
channelInFrameRate Counter32,
channelOutOctetRate Counter32,
channelOutFrameRate Counter32,
channelPkts64Octets Counter32,
channelPkts65to127Octets Counter32,
channelPkts128to255Octets Counter32,
channelPkts256to511Octets Counter32,
channelPkts512to1023Octets Counter32,
channelPkts1024to1518Octets Counter32,
channelInFrames Counter32,
channelInOctets Counter32,
channelInDiscards Counter32,
channelInUcastPkts Counter32,
channelInMulticastPkts Counter32,
channelInBroadcastPkts Counter32,
channelInErrors Counter32,
channelFCSErrors Counter32,
channelSymbolErrors Counter32,
channelCarrierSenseErrors Counter32,
channelUndersizePkts Counter32,
channelOversizePkts Counter32,
channelFragments Counter32,
channelJabbers Counter32,
channelOutFrames Counter32,
channelOutOctets Counter32,
channelOutDiscards Counter32,
channelOutUcastPkts Counter32,
channelOutMulticastPkts Counter32,
channelOutBroadcastPkts Counter32,
channelOutErrors Counter32,
channelDeferredTransmissions Counter32,
channelCollisions Counter32,
channelLateCollisions Counter32
}
channelGroupIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configed channel-group index list."
--<2D><><EFBFBD><EFBFBD><EFBFBD>õĻ<C3B5><C4BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>б<EFBFBD>
::= { channelStatsEntry 1 }
channelInOctetRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress octet rate of this channel-group."
--<2D>û<EFBFBD><C3BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ձ<EFBFBD><D5B1><EFBFBD><EFBFBD>ֽڵ<D6BD><DAB5><EFBFBD><EFBFBD><EFBFBD>
::= { channelStatsEntry 2 }
channelInFrameRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress packet rate of this channel-group."
--<2D>û<EFBFBD><C3BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ձ<EFBFBD><D5B1>ĵ<EFBFBD><C4B5><EFBFBD><EFBFBD><EFBFBD>
::= { channelStatsEntry 3 }
channelOutOctetRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress octet rate of this channel-group."
--<2D>û<EFBFBD><C3BB><EFBFBD><EFBFBD><EFBFBD>ͱ<EFBFBD><CDB1><EFBFBD><EFBFBD>ֽڵ<D6BD><DAB5><EFBFBD><EFBFBD><EFBFBD>
::= { channelStatsEntry 4 }
channelOutFrameRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress packet rate of this channel-group."
--<2D>û<EFBFBD><C3BB><EFBFBD><EFBFBD><EFBFBD>ͱ<EFBFBD><CDB1>ĵ<EFBFBD><C4B5><EFBFBD><EFBFBD><EFBFBD>
::= { channelStatsEntry 5 }
channelPkts64Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)
in this channel-group."
::= { channelStatsEntry 6 }
channelPkts65to127Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)
in this channel-group."
::= { channelStatsEntry 7 }
channelPkts128to255Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets).
in this channel-group."
::= { channelStatsEntry 8 }
channelPkts256to511Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)
in this channel-group."
::= { channelStatsEntry 9 }
channelPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)
in this channel-group."
::= { channelStatsEntry 10 }
channelPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)
in this channel-group."
::= { channelStatsEntry 11 }
channelInFrames OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been received by
this channel-group from its segment. Note that a frame
received on the interface corresponding to this
channel-group is only counted by this object if and
only if it is for a protocol being processed by the
local bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { channelStatsEntry 12 }
channelInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the channel-group,
including framing characters.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 13 }
channelInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets which were chosen to be
discarded even though no errors had been detected to
prevent their being deliverable to a higher-layer
protocol. One possible reason for discarding such a
packet could be to free up buffer space.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 14 }
channelInUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were not addressed to a
multicast or broadcast address at this sub-layer.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 15 }
channelInMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast address at this sub-layer. For a MAC layer
protocol, this includes both Group and Functional
addresses.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 16 }
channelInBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 17 }
channelInErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of inbound
packets that contained errors preventing them from
being deliverable to a higher-layer protocol. For
character-oriented or fixed-length interfaces, the
number of inbound transmission units that contained
errors preventing them from being deliverable to a
higher-layer protocol.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 18 }
channelFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of frames received on a particular
interface that are an integral number of octets
in length but do not pass the FCS check.
The count represented by an instance of this
object is incremented when the frameCheckError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
REFERENCE
"IEEE 802.3 Layer Management"
::= { channelStatsEntry 19 }
channelSymbolErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For an interface operating at 100 Mb/s, the
number of times there was an invalid data symbol
when a valid carrier was present.
For an interface operating in half-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle (a carrier event) for a period
of time equal to or greater than slotTime, and
during which there was at least one occurrence
of an event that causes the PHY to indicate
'Data reception error' or 'carrier extend error'
on the GMII.
For an interface operating in full-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle a carrier event) for a period
of time equal to or greater than minFrameSize,
and during which there was at least one
occurrence of an event that causes the PHY to
indicate 'Data reception error' on the GMII.
The count represented by an instance of this
object is incremented at most once per carrier
event, even if multiple symbol errors occur
during the carrier event. This count does
not increment if a collision is present.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE
"[IEEE 802.3 Std.], 30.3.2.1.5,
aSymbolErrorDuringCarrier."
::= { channelStatsEntry 20 }
channelCarrierSenseErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that the carrier sense
condition was lost or never asserted when
attempting to transmit a frame on a particular
interface.
The count represented by an instance of this
object is incremented at most once per
transmission attempt, even if the carrier sense
condition fluctuates during a transmission
attempt."
REFERENCE
"IEEE 802.3 Layer Management"
::= { channelStatsEntry 21 }
channelUndersizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { channelStatsEntry 22 }
channelOversizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { channelStatsEntry 23 }
channelFragments OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less
than 64 octets in length (excluding framing bits but
including FCS octets) and had either a bad Frame
Check Sequence (FCS) with an integral number of
octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Note that it is entirely normal for
etherStatsFragments to increment. This is because
it counts both runts (which are normal occurrences
due to collisions) and noise hits."
::= { channelStatsEntry 24 }
channelJabbers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { channelStatsEntry 25 }
channelOutFrames OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been transmitted
by this channel-group to its segment. Note that a
frame transmitted on the interface corresponding
to this port is only counted by this object if and
only if it is for a protocol being processed by the
local bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { channelStatsEntry 26 }
channelOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
channel-group, including framing characters.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 27 }
channelOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets which were chosen to
be discarded even though no errors had been detected
to prevent their being transmitted. One possible
reason for discarding such a packet could be to free
up buffer space.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 28 }
channelOutUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were not
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 29 }
channelOutMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast address at this sub-layer,
including those that were discarded or not sent. For
a MAC layer protocol, this includes both Group and
Functional addresses.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 30 }
channelOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 31 }
channelOutErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of
outbound packets that could not be transmitted because
of errors. For character-oriented or fixed-length
interfaces, the number of outbound transmission units
that could not be transmitted because of errors.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsEntry 32 }
channelDeferredTransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of frames for which the first
transmission attempt on a particular interface
is delayed because the medium is busy.
The count represented by an instance of this
object does not include frames involved in
collisions."
REFERENCE
"IEEE 802.3 Layer Management"
::= { channelStatsEntry 33 }
channelCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment.
The value returned will depend on the location of
the RMON probe. Section 8.2.1.3 (10BASE-5) and
section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
states that a station must detect a collision, in
the receive mode, if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coax segments to which
the repeater is connected."
::= { channelStatsEntry 34 }
channelLateCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that a collision is
detected on a particular interface later than
512 bit-times into the transmission of a
packet.
Five hundred and twelve bit-times corresponds
to 51.2 microseconds on a 10 Mbit/s system. A
(late) collision included in a count
represented by an instance of this object is
also considered as a (generic) collision for
purposes of other collision-related
statistics."
REFERENCE
"IEEE 802.3 Layer Management"
::= { channelStatsEntry 35 }
-- The channelStatsXEntry
channelStatsXTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelStatsXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Channel group Statistics Info(64)."
::= { gbnDeviceSwitchChannelStats 2 }
channelStatsXEntry OBJECT-TYPE
SYNTAX ChannelStatsXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for Channel Statistics information(64)."
AUGMENTS { channelStatsEntry }
::= { channelStatsXTable 1 }
ChannelStatsXEntry ::= SEQUENCE {
channelHCInFrames Counter64,
channelHCInOctets Counter64,
channelHCInUcastPkts Counter64,
channelHCInMulticastPkts Counter64,
channelHCInBroadcastPkts Counter64,
channelHCInDiscards Counter64,
channelHCOutFrames Counter64,
channelHCOutOctets Counter64,
channelHCOutUcastPkts Counter64,
channelHCOutMulticastPkts Counter64,
channelHCOutBroadcastPkts Counter64
}
channelHCInFrames OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been received by
this channel-group from its segment. Note that a
frame received on the interface corresponding to
this channel-group is only counted by this object
if and only if it is for a protocol being processed
by the local bridging function, including bridge
management frames.
This object is a 64-bit version of channelInFrames."
REFERENCE
"ISO/IEC 15802-3 Section 14.6.1.1.3"
::= { channelStatsXEntry 1 }
channelHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the channel-group,
including framing characters. This object is a 64-bit
version of channelInOctets.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 2 }
channelHCInUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were not addressed to a
multicast or broadcast address at this sub-layer.
This object is a 64-bit version of channelInUcastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 3 }
channelHCInMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast address at this sub-layer. For a MAC layer
protocol, this includes both Group and Functional
addresses. This object is a 64-bit version of
channelInMulticastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 4 }
channelHCInBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer. This object is a
64-bit version of channelInBroadcastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 5 }
channelHCInDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of valid frames that have been received by this
channel-group from its segment which were discarded (i.e.,
filtered) by the Forwarding Process."
REFERENCE
"ISO/IEC 15802-3 Section 14.6.1.1.3"
::= { channelStatsXEntry 6 }
channelHCOutFrames OBJECT-TYPE
SYNTAX Counter64
ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been transmitted
by this channel-group to its segment. Note that a
frame transmitted on the interface corresponding
to this channel-group is only counted by this
object if and only if it is for a protocol being
processed by the local bridging function, including
bridge management frames.
This object is a 64-bit version of channelOutFrames."
REFERENCE
"ISO/IEC 15802-3 Section 14.6.1.1.3"
::= { channelStatsXEntry 7 }
channelHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
channel-group, including framing characters. This
object is a 64-bit version of channelOutOctets.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 8 }
channelHCOutUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were not
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent. This object is a 64-bit version of channelOutUcastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 9 }
channelHCOutMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast address at this sub-layer,
including those that were discarded or not sent. For
a MAC layer protocol, this includes both Group and
Functional addresses. This object is a 64-bit version
of channelOutMulticastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 10 }
channelHCOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent. This
object is a 64-bit version of channelOutBroadcastPkts.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { channelStatsXEntry 11 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchRemoteMirror - Mirror Group
--
------------------------------------------------------------------------------
remoteMirrorVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteMirrorVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch interfaces and associated properties."
::= { gbnDeviceSwitchRmoteMirror 1 }
remoteMirrorVlanEntry OBJECT-TYPE
SYNTAX RemoteMirrorVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for switch interface control and status information."
INDEX { remoteMirrorVlanIndex }
::= { remoteMirrorVlanTable 1 }
RemoteMirrorVlanEntry ::= SEQUENCE {
remoteMirrorVlanIndex INTEGER,
remoteMirrorVlanEnable TruthValue
}
remoteMirrorVlanIndex OBJECT-TYPE
SYNTAX INTEGER (2..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the index of remote mirror vlan."
::= { remoteMirrorVlanEntry 1 }
remoteMirrorVlanEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1:enable. 2 disable"
::= { remoteMirrorVlanEntry 2 }
remoteMirrorRspanVlanSet OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set rspan vlan on src-switch,
0:means no rspan vlan;don't set vlan 1 to be rspan vlan"
::= { gbnDeviceSwitchRmoteMirror 2 }
remoteMirrorEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable remote mirror on src-switch"
::= { gbnDeviceSwitchRmoteMirror 3 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchPortSFPInfo - Port SFP Information
--
------------------------------------------------------------------------------
portSFPInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch interfaces and associated properties."
::= { gbnDeviceSwitchPortSFPInfo 1 }
portSFPInfoEntry OBJECT-TYPE
SYNTAX PortSFPInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for switch interface control and status information."
INDEX { portSFPNumber }
::= { portSFPInfoTable 1 }
PortSFPInfoEntry ::= SEQUENCE {
portSFPNumber INTEGER,
transceiverType INTEGER,
compliance DisplayString,
connectorType INTEGER,
waveLength INTEGER,
transferDistance INTEGER,
digitalDiagnosticMonitor INTEGER,
vendorName DisplayString,
manuSerialNumber DisplayString,
manufacturingDate DisplayString,
temperature INTEGER,
voltage DisplayString,
biasCurrent DisplayString,
biasHighThreshold DisplayString,
biasLowThreshold DisplayString,
rxPower DisplayString,
rxPowerHighThreshold DisplayString,
rxPowerLowThreshold DisplayString,
txPower DisplayString,
txPowerHighThreshold DisplayString,
txPowerLowThreshold DisplayString
}
portSFPNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of port."
::= { portSFPInfoEntry 1 }
transceiverType OBJECT-TYPE
SYNTAX INTEGER {
SFPNotExist(0),
GBIC(1),
SFF(2),
SFP(3),
XBI(4),
Xenpak(5),
XFP(6),
XFF(7),
XFP-E(8),
XPak(9),
X2(10),
DWDM-SFP(11),
QSFP(12),
Unknown(99)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver type"
::= { portSFPInfoEntry 2 }
compliance OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Compliance type"
::= { portSFPInfoEntry 3 }
connectorType OBJECT-TYPE
SYNTAX INTEGER {
SFPNotExist(0),
SC(1),
FibreChannelStyle1CopperConnector(2),
FibreChannelStyle2CopperConnector(3),
BNCTNC(4),
FibreChannelCoaxialHeaders(5),
FiberJack(6),
LC(7),
MT-RJ(8),
MU(9),
SG(10),
OpticalPigtail(11),
MPOParallelOptic(12),
HSSDCII(32),
CopperPigtail(33),
RJ45(34),
Electrical-Mode(35),
Unknown(99)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connector type"
::= { portSFPInfoEntry 4 }
waveLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave length."
::= { portSFPInfoEntry 5 }
transferDistance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transfer distance."
::= { portSFPInfoEntry 6 }
digitalDiagnosticMonitor OBJECT-TYPE
SYNTAX INTEGER {
SFPNotExist(0),
NotSupported(1),
Supported(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Digital Diagnostic Monitor."
::= { portSFPInfoEntry 7 }
vendorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor Name."
::= { portSFPInfoEntry 8 }
manuSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacture Serial Number."
::= { portSFPInfoEntry 9 }
manufacturingDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacturing Date."
::= { portSFPInfoEntry 10 }
temperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of sfp."
::= { portSFPInfoEntry 11 }
voltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Voltage of sfp."
::= { portSFPInfoEntry 12 }
biasCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"bias Current."
::= { portSFPInfoEntry 13 }
biasHighThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"bias Current High Threshold."
::= { portSFPInfoEntry 14 }
biasLowThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"bias Current Low Threshold."
::= { portSFPInfoEntry 15 }
rxPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX Power."
::= { portSFPInfoEntry 16 }
rxPowerHighThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX Power High Threshold."
::= { portSFPInfoEntry 17 }
rxPowerLowThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX Power Low Threshold."
::= { portSFPInfoEntry 18 }
txPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX Power."
::= { portSFPInfoEntry 19 }
txPowerHighThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX Power High Threshold."
::= { portSFPInfoEntry 20 }
txPowerLowThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX Power Low Threshold."
::= { portSFPInfoEntry 21 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchPortAvgRate - Port Average Rate Statistics Info
--
------------------------------------------------------------------------------
portRateStatisticsInterval OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"port average rate statistics time interval, unit is minute, default is 5 minutes."
::= { gbnDeviceSwitchPortAvgRate 1 }
portAvgRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortAvgRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of port average rate statistics info(32)."
::= { gbnDeviceSwitchPortAvgRate 2 }
portAvgRateEntry OBJECT-TYPE
SYNTAX PortAvgRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for port average rate statistics information(32)."
INDEX { portIndex }
::= { portAvgRateTable 1 }
PortAvgRateEntry ::= SEQUENCE {
portIndex INTEGER,
portInOctetRate Counter32,
portInFrameRate Counter32,
portOutOctetRate Counter32,
portOutFrameRate Counter32
}
portIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index list."
::= { portAvgRateEntry 1 }
portInOctetRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress octet rate of this port."
::= { portAvgRateEntry 2 }
portInFrameRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress packet rate of this port."
::= { portAvgRateEntry 3 }
portOutOctetRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress octet rate of this port."
::= { portAvgRateEntry 4 }
portOutFrameRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress packet rate of this port."
::= { portAvgRateEntry 5 }
------------------------------------------------------------------------------
--
-- gbnDeviceSwitchPortbandwidthUtilization - Port Average bandwidth utilization Info
--
------------------------------------------------------------------------------
portBandwidthUtilizationEnable OBJECT-TYPE
SYNTAX TruthValue
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port bandwidth switch."
::= { gbnDeviceSwitchPortbandwidthUtilization 1 }
portBandwidthUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortBandwidthUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of port bandwidth utilization info(32)."
::= { gbnDeviceSwitchPortbandwidthUtilization 2 }
portBandwidthUtilizationEntry OBJECT-TYPE
SYNTAX PortBandwidthUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for port bandwidth utilization information(32)."
INDEX { portBandIndex }
::= { portBandwidthUtilizationTable 2 }
PortBandwidthUtilizationEntry ::= SEQUENCE {
portBandIndex INTEGER,
portInBandwidthUtilization Counter32,
portOutBandwidthUtilization Counter32
}
portBandIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index list."
::= { portBandwidthUtilizationEntry 1 }
portInBandwidthUtilization OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress bandwidth utilization of this port."
::= { portBandwidthUtilizationEntry 2 }
portOutBandwidthUtilization OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The egress bandwidth utilization of this port."
::= { portBandwidthUtilizationEntry 3 }
--
-- END of gbnDeviceSwitch-MIB
--
END