mibs/MIBS/hillstone/HILLSTONE-SYSTEM-MIB

165 lines
3.8 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- **********************************************************************
-- HILLSTONE-SYSTEM-MIB
--
-- Copyright (c) 2009 by Hillstone Networks, Inc.
-- All rights reserved.
--
-- Version: V3
-- Description: Hillstone Networks SYSTEM MIB Object Identifier Assignments
-- **********************************************************************
--
HILLSTONE-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY FROM SNMPv2-SMI
NetworkAddress, IpAddress,
Counter, Gauge, TimeTicks FROM RFC1155-SMI
TruthValue FROM SNMPv2-TC
hillstoneSys FROM HILLSTONE-SMI;
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
hillstoneSysMibObjects OBJECT IDENTIFIER ::= { hillstoneSys 1 }
-- hillstone systems
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 1 }
sysSoftware OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 2 }
sysCPU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 3 }
sysTotalMemory OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 4 }
sysCurMemory OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 5 }
sysTotalSession OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 6 }
sysCurSession OBJECT-TYPE
SYNTAX Gauge32
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 7 }
sysHAStatus OBJECT-TYPE
SYNTAX INTEGER
{
none (0),
init (1),
hello (2),
backup (3),
master (4),
slase (5),
AA-mode (6)
}
ACCESS read-only
STATUS mandatory
::= { hillstoneSysMibObjects 8 }
sysSnmpStackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of snmp Stack."
::= { hillstoneSysMibObjects 9 }
sysTr069StackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of tr069 stack."
::= { hillstoneSysMibObjects 10 }
sysVedorOUI OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The oui code of the Tr069 stack.."
::= { hillstoneSysMibObjects 11 }
sysLogStackStatus OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION
"The running status of syslog stack."
::= { hillstoneSysMibObjects 12 }
sysLogServerAddress1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The syslog receiver addrees 1."
::= { hillstoneSysMibObjects 13 }
sysLogServerAddress2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"The syslog receiver addrees 2."
::= { hillstoneSysMibObjects 14 }
sysDeviceReloadAction OBJECT-TYPE
SYNTAX INTEGER
{
reloadUnAvailable(1),
reloadAtOnce(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The actioin of reloading the device. when the value is set to 2,the device will reboot at once."
::= { hillstoneSysMibObjects 15 }
sysStatisticsPeriod OBJECT-TYPE
SYNTAX INTEGER
{
oneDay(1)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The period of statistics. default statistics period is 24hours"
::= { hillstoneSysMibObjects 16 }
END