2023-12-05 12:25:34 +01:00
-- ****************************************************************************
--
-- Host Operating System Information
-- Management Information Base for SNMP Network Management
--
--
-- Copyright 1993,2016 Hewlett Packard Enterprise Development, L.P.
--
-- Hewlett Packard Enterprise Development LP shall not be liable for technical or
-- editorial errors or omissions contained herein. The information in
-- this document is provided "as is" without warranty of any kind and
-- is subject to change without notice. The warranties for HP products
-- are set forth in the express limited warranty statements
-- accompanying such products. Nothing herein should be construed as
-- constituting an additional warranty.
--
-- Confidential computer software. Valid license from HP required for
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
-- Commercial Computer Software, Computer Software Documentation, and
-- Technical Data for Commercial Items are licensed to the U.S.
-- Government under vendor's standard commercial license.
--
-- Refer to the READMIB.RDM file for more information about the
-- organization of the information in the Compaq Enterprise.
--
-- The Compaq Enterprise number is 232.
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
-- 1.3.6.1.4.1.232
--
-- ****************************************************************************
CPQHOST-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
IpAddress FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
sysName FROM RFC1213-MIB;
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 }
cpqHoMibRev OBJECT IDENTIFIER ::= { cpqHostOs 1 }
cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 }
cpqHoInterface OBJECT IDENTIFIER ::= { cpqHoComponent 1 }
cpqHoInfo OBJECT IDENTIFIER ::= { cpqHoComponent 2 }
cpqHoUtil OBJECT IDENTIFIER ::= { cpqHoComponent 3 }
cpqHoFileSys OBJECT IDENTIFIER ::= { cpqHoComponent 4 }
-- The cpqHoIfPhysMap group has been deprecated.
cpqHoIfPhysMap OBJECT IDENTIFIER ::= { cpqHoComponent 5 }
cpqHoSWRunning OBJECT IDENTIFIER ::= { cpqHoComponent 6 }
cpqHoSwVer OBJECT IDENTIFIER ::= { cpqHoComponent 7 }
cpqHoGeneric OBJECT IDENTIFIER ::= { cpqHoComponent 8 }
cpqHoSwPerf OBJECT IDENTIFIER ::= { cpqHoComponent 9 }
cpqHoSystemStatus OBJECT IDENTIFIER ::= { cpqHoComponent 10 }
cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 }
cpqHoClients OBJECT IDENTIFIER ::= { cpqHoComponent 12 }
cpqHoMemory OBJECT IDENTIFIER ::= { cpqHoComponent 13 }
cpqHoFwVer OBJECT IDENTIFIER ::= { cpqHoComponent 14 }
cpqHoHWInfo OBJECT IDENTIFIER ::= { cpqHoComponent 15 }
cpqPwrThreshold OBJECT IDENTIFIER ::= { cpqHoComponent 16 }
cpqHoOsCommon OBJECT IDENTIFIER ::= { cpqHoInterface 4 }
-- ****************************************************************************
-- Host OS Information MIB Revision
-- ================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoMibRev Group (1.3.6.1.4.1.232.11.1)
--
-- Implementation of the cpqHoMibRev group is mandatory for all agents
-- supporting the Host OS MIB.
--
-- A Management Agent conforming to this document will return a
-- cpqHoMibRevMajor of one (1) and a cpqHoMibRevMinor of forty three (43).
--
-- ****************************************************************************
cpqHoMibRevMajor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Major Revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information.
Correct interpretation of data may require a MIB document with
the same major revision level."
::= { cpqHoMibRev 1 }
cpqHoMibRevMinor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Minor Revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred."
::= { cpqHoMibRev 2 }
cpqHoMibCondition OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), -- default state
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition.
This object represents the overall status of the server's host
system represented by this MIB."
::= { cpqHoMibRev 3 }
-- ****************************************************************************
-- Host OS Common
-- ==============
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoInterface Group (1.3.6.1.4.1.232.11.2.1)
-- cpqHoOsCommon Group (1.3.6.1.4.1.232.11.2.1.4)
--
--
-- Implementation of the cpqHoOsCommon group is mandatory for all
-- agents that support the Host OS MIB.
--
-- ****************************************************************************
cpqHoOsCommonPollFreq OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail. An agent may choose to fail any request to change
the poll frequency to a value that would severely impact system
performance."
::= { cpqHoOsCommon 1 }
-- ****************************************************************************
-- Host OS Common Module Table
-- ===========================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoInterface Group (1.3.6.1.4.1.232.11.2.1)
-- cpqHoOsCommon Group (1.3.6.1.4.1.232.11.2.1.4)
-- cpqHoOsCommonModuleTable (1.3.6.1.4.1.232.11.2.1.4.2) deprecated
--
-- ****************************************************************************
cpqHoOsCommonModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoOsCommonModuleEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table of software modules that provide an interface to the
device this MIB describes."
::= { cpqHoOsCommon 2 }
cpqHoOsCommonModuleEntry OBJECT-TYPE
SYNTAX CpqHoOsCommonModuleEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A description of a software module that provides an interface
to the device this MIB describes."
INDEX { cpqHoOsCommonModuleIndex }
::= { cpqHoOsCommonModuleTable 1 }
CpqHoOsCommonModuleEntry ::= SEQUENCE {
cpqHoOsCommonModuleIndex INTEGER,
cpqHoOsCommonModuleName DisplayString,
cpqHoOsCommonModuleVersion DisplayString,
cpqHoOsCommonModuleDate OCTET STRING,
cpqHoOsCommonModulePurpose DisplayString
}
cpqHoOsCommonModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique index for this module description."
::= { cpqHoOsCommonModuleEntry 1 }
cpqHoOsCommonModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module name."
::= { cpqHoOsCommonModuleEntry 2 }
cpqHoOsCommonModuleVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be null (size 0) string if the agent
cannot provide the module version."
::= { cpqHoOsCommonModuleEntry 3 }
cpqHoOsCommonModuleDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first."
::= { cpqHoOsCommonModuleEntry 4 }
cpqHoOsCommonModulePurpose OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The purpose of the module described in this entry."
::= { cpqHoOsCommonModuleEntry 5 }
-- ****************************************************************************
-- Host OS Information Group
-- =========================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoInfo Group (1.3.6.1.4.1.232.11.2.2)
--
--
-- The cpqHoInfo group describes some general information about the
-- host OS.
--
-- Implementation of the cpqHoInfo group is mandatory for all
-- agents supporting the Host OS MIB.
--
-- ****************************************************************************
cpqHoName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the host operating system (OS)."
::= { cpqHoInfo 1 }
cpqHoVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the host OS."
::= { cpqHoInfo 2 }
cpqHoDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A further description of the host OS."
::= { cpqHoInfo 3 }
cpqHoOsType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
netware(2), -- Novell NetWare
windowsnt(3), -- Microsoft Windows NT
sco-unix(4), -- SCO OpenServer
unixware(5), -- SCO UnixWare
os-2(6), -- IBM OS/2
ms-dos(7), -- Microsoft DOS
dos-windows(8), -- Microsoft DOS + Microsoft Windows
windows95(9), -- Microsoft Windows 95
windows98(10), -- Microsoft Windows 98
open-vms(11), -- Open VMS
nsk(12), -- Non Stop Kernel
windowsCE(13), -- Microsoft Windows CE
linux(14), -- Linux
windows2000(15), -- Microsoft Windows 2000
tru64UNIX(16), -- Tru64 UNIX
windows2003(17), -- Microsoft Windows Server 2003
windows2003-x64(18), -- Microsoft Windows Server 2003 x64 Edition
solaris(19), -- Sun Solaris
windows2003-ia64(20), -- Microsoft Windows Server 2003 for Itanium-based Systems
windows2008(21), -- Microsoft Windows Server 2008
windows2008-x64(22), -- Microsoft Windows Server 2008 x64 Edition
windows2008-ia64(23), -- Microsoft Windows Server 2008 for Itanium-based Systems
vmware-esx(24), -- VMware ESX Classic
vmware-esxi(25), -- VMware ESXi
windows2012(26), -- Microsoft Windows 2012 Server
windows7(27), -- Microsoft Windows 7
windows7-x64(28), -- Microsoft Windows 7 64-bit
windows8(29), -- Microsoft Windows 8
windows8-x64(30), -- Microsoft Windows 8 64-bit
windows81(31), -- Microsoft Windows 8.1
windows81-x64(32), -- Microsoft Windows 8.1 64-bit
windowsxp(33), -- Microsoft Windows XP
windowsxp-x64(34), -- Microsoft Windows XP 64-Bit
windowsvista(35), -- Microsoft Windows Vista
windowsvista-x64(36), -- Microsoft Windows Vista 64-Bit
windows2008-r2(37), -- Microsoft Windows Server 2008 R2
windows2012-r2(38), -- Microsoft Windows Server 2012 R2
rhel(39), -- RedHat Enterprise Linux
rhel-64(40), -- RedHat Enterprise Linux 64-Bit
solaris-64(41), -- Solaris 64-Bit
sles(42), -- SUSE Linux Enterprise Server
sles-64(43), -- SUSE Linux Enterprise Server 64-Bit
ubuntu(44), -- Ubuntu
ubuntu-64(45), -- Ubuntu 64-Bit
debian(46), -- Debian
debian-64(47), -- Debian 64-Bit
linux-64-bit(48), -- Linux 64-Bit
other-64-bit(49), -- Other 64-Bit
centos-32bit(50), -- CentOS 32-bit
centos-64bit(51), -- CentOS 64-bit
oracle-linux32(52), -- Oracle Linux 32-bit
oracle-linux64(53), -- Oracle Linux 64-bit
apple-osx(54), -- Apple OS X
windows2016(55), -- Microsoft Windows Server 2016
nanoserver(56) -- Nano Server
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Operating system enumeration."
::= { cpqHoInfo 4 }
cpqHoTelnet OBJECT-TYPE
SYNTAX INTEGER {
other(1),
available(2),
notavailable(3) -- default
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Telnet on socket 23 is available."
--
-- This variable specifies the availability of telnet. Only socket 23 is
-- checked for telnet services.
--
::= { cpqHoInfo 5 }
cpqHoSystemRole OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The system role.
This is a settable free form text field intended to be assigned
by a remote console briefly describing the system's function."
::= { cpqHoInfo 6 }
cpqHoSystemRoleDetail OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..512))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The system detailed description.
This is a settable free form text field intended to be assigned
by a remote console describing the system function in detail."
::= { cpqHoInfo 7 }
cpqHoCrashDumpState OBJECT-TYPE
SYNTAX INTEGER {
completememorydump(1),
kernelmemorydump(2),
smallmemorydump(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Crash dump state.
Value of 'Unknown (-1)' is returned when crash dump state could
not be determined."
::= { cpqHoInfo 8 }
cpqHoCrashDumpCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- (Crash Dump settings unknown) or (Crash dump monitoring is disabled)
ok(2), -- (Crash dump settings OK) and (paging file size >= minimum) and (free disk space >= minimum)
degraded(3), -- (Crash dump settings none) or (paging file size < minimum) or (free disk space < minimum)
failed(4) -- N/A
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The condition of the Crash dump configuration."
::= { cpqHoInfo 9 }
cpqHoCrashDumpMonitoring OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- Enable crash dump monitoring.
disabled(2) -- Disable crash dump monitoring.
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Enable/disable crash dump monitoring.
If crash dump monitoring is enabled both crash dump TRAP's
are generated and crash dump condition is updated.
If crash dump monitoring is disabled, no crash dump TRAP
is generated and the crash dump condition is set to
other"
::= { cpqHoInfo 10 }
cpqHoMaxLogicalCPUSupported OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"Maximum number of logical CPUs supported by Operating System."
::= { cpqHoInfo 11 }
cpqHoSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Full computer name of the host"
::= { cpqHoInfo 12 }
cpqHosysDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The value that would be returned in the RFC-1213
sysDescr MIB element. It should include the full
name and version identification of the system's
hardware type, software operating-system, and
networking software. It is mandatory that this only
contain printable ASCII characters."
::= { cpqHoInfo 13}
-- ****************************************************************************
-- Host OS CPU Utilization Table
-- =============================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoUtil Group (1.3.6.1.4.1.232.11.2.3)
-- cpqHoCpuUtilTable (1.3.6.1.4.1.232.11.2.3.1)
--
--
-- The cpqHoUtil group contains measures of system utilization.
--
-- Implementation of the cpqHoUtil group is mandatory for all agents
-- that support the Host OS MIB.
--
-- ****************************************************************************
cpqHoCpuUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoCpuUtilEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of CPU utilization entries."
::= { cpqHoUtil 1 }
cpqHoCpuUtilEntry OBJECT-TYPE
SYNTAX CpqHoCpuUtilEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a CPU's utilization."
INDEX { cpqHoCpuUtilUnitIndex }
::= { cpqHoCpuUtilTable 1 }
CpqHoCpuUtilEntry ::= SEQUENCE {
cpqHoCpuUtilUnitIndex INTEGER,
cpqHoCpuUtilMin INTEGER,
cpqHoCpuUtilFiveMin INTEGER,
cpqHoCpuUtilThirtyMin INTEGER,
cpqHoCpuUtilHour INTEGER,
cpqHoCpuUtilHwLocation DisplayString
}
cpqHoCpuUtilUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This number uniquely specifies a processor unit.
A processing unit may be a set of processing chips that are
on the same board or for other reasons work together as a unit.
The main processor unit (if such a concept is valid for this
machine) will always have the lowest (first) index."
::= { cpqHoCpuUtilEntry 1 }
cpqHoCpuUtilMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last minute. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 2 }
cpqHoCpuUtilFiveMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last five minutes. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 3 }
cpqHoCpuUtilThirtyMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last thirty minutes. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 4 }
cpqHoCpuUtilHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last hour. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 5 }
cpqHoCpuUtilHwLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A text description of the hardware location, on complex
multi SBB hardware only, for the CPU.
A NULL string indicates that the hardware location could not
be determined or is irrelevant."
::= { cpqHoCpuUtilEntry 6 }
-- ****************************************************************************
-- Host OS File System Table
-- =========================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoFileSys Group (1.3.6.1.4.1.232.11.2.4)
-- cpqHoFileSysTable (1.3.6.1.4.1.232.11.2.4.1)
--
-- The cpqHoFileSys group contains configuration and status information
-- about the file system.
--
-- ****************************************************************************
cpqHoFileSysTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoFileSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of file system descriptions."
::= { cpqHoFileSys 1 }
cpqHoFileSysEntry OBJECT-TYPE
SYNTAX CpqHoFileSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A file system description."
INDEX { cpqHoFileSysIndex }
::= { cpqHoFileSysTable 1 }
CpqHoFileSysEntry ::= SEQUENCE {
cpqHoFileSysIndex INTEGER,
cpqHoFileSysDesc DisplayString,
cpqHoFileSysSpaceTotal INTEGER,
cpqHoFileSysSpaceUsed INTEGER,
cpqHoFileSysPercentSpaceUsed INTEGER,
cpqHoFileSysAllocUnitsTotal INTEGER,
cpqHoFileSysAllocUnitsUsed INTEGER,
cpqHoFileSysStatus INTEGER,
cpqHoFileSysShortDesc DisplayString
}
cpqHoFileSysIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoFileSysEntry 1 }
cpqHoFileSysDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the file system include the GUID."
::= { cpqHoFileSysEntry 2 }
cpqHoFileSysSpaceTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The file system size in megabytes.
This item will be set to -1 if the agent is unable to determine
this information."
::= { cpqHoFileSysEntry 3 }
cpqHoFileSysSpaceUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The megabytes of file system space currently in use.
This item will be set to -1 if the agent is unable to determine
this information."
::= { cpqHoFileSysEntry 4 }
cpqHoFileSysPercentSpaceUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percent of file system space currently in use.
This item will be set to -1 if this information is not
available."
::= { cpqHoFileSysEntry 5 }
cpqHoFileSysAllocUnitsTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of files (directory entries) that can be
stored on the file system if a limit exists other than
total space used. This item will be set to -1 if no such
limit exists."
::= { cpqHoFileSysEntry 6 }
cpqHoFileSysAllocUnitsUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of files (directory entries) on this file system.
This item will be set to -1 if the agent does not determine this
information."
::= { cpqHoFileSysEntry 7 }
cpqHoFileSysStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), -- default state
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Threshold Status.
This object represent the status of the Filesystem threshold."
::= { cpqHoFileSysEntry 8 }
cpqHoFileSysShortDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the file system."
::= { cpqHoFileSysEntry 9 }
-- ****************************************************************************
-- Host OS File System Table
-- =========================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoFileSys Group (1.3.6.1.4.1.232.11.2.4)
-- cpqHoFileSysCondition (1.3.6.1.4.1.232.11.2.4.2)
--
-- The cpqHoFileSys group contains overall condition of Filesystem Threshold
--
-- ****************************************************************************
cpqHoFileSysCondition OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), -- default state
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition of File System Threshold.
This object represents the overall status of the server's
File System Threshold."
::= { cpqHoFileSys 2 }
-- ****************************************************************************
-- Host OS Interface Physical Map Table
-- ====================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoIfPhysMap Group (1.3.6.1.4.1.232.11.2.5) deprecated
-- cpqHoIfPhysMapTable (1.3.6.1.4.1.232.11.2.5.1) deprecated
--
--
-- The cpqHoIfPhysMap group contains information to map interface numbers
-- in the MIB-II interface group to the physical interface cards that
-- implement the interface.
--
-- Implementation of the cpqHoIfPhysMap group is mandatory for all agents
-- that support the Host OS MIB.
--
-- ****************************************************************************
cpqHoIfPhysMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoIfPhysMapEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table of interface to physical hardware mappings."
::= { cpqHoIfPhysMap 1 }
cpqHoIfPhysMapEntry OBJECT-TYPE
SYNTAX CpqHoIfPhysMapEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A mapping of an interface table entry to physical hardware."
INDEX { cpqHoIfPhysMapIndex }
::= { cpqHoIfPhysMapTable 1 }
CpqHoIfPhysMapEntry ::= SEQUENCE {
cpqHoIfPhysMapIndex INTEGER,
cpqHoIfPhysMapSlot INTEGER,
cpqHoIfPhysMapIoBaseAddr INTEGER,
cpqHoIfPhysMapIrq INTEGER,
cpqHoIfPhysMapDma INTEGER,
cpqHoIfPhysMapMemBaseAddr INTEGER,
cpqHoIfPhysMapPort INTEGER,
cpqHoIfPhysMapDuplexState INTEGER,
cpqHoIfPhysMapCondition INTEGER
}
cpqHoIfPhysMapIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"An index that uniquely specifies this entry. This value is
equal to the index of the entry in the MIB-II interface table
to which this entry corresponds."
::= { cpqHoIfPhysMapEntry 1 }
cpqHoIfPhysMapSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the slot containing the physical hardware that
implements this interface. The number zero (0) indicates an
embedded interface (on the system board) or an interface whose
slot is unknown. Values may be unknown if the physical
hardware has not been configured using the EISA Configuration
Utility."
::= { cpqHoIfPhysMapEntry 2 }
cpqHoIfPhysMapIoBaseAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The base I/O address of the physical hardware that implements
this interface."
::= { cpqHoIfPhysMapEntry 3 }
cpqHoIfPhysMapIrq OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the IRQ (interrupt) used for this physical
hardware interface. The number zero (0) indicates that this
device does not use an IRQ or this information is unavailable."
::= { cpqHoIfPhysMapEntry 4 }
cpqHoIfPhysMapDma OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the DMA channel used for this physical hardware
interface. The number -1 indicates that this device does not
use a DMA channel or this information is unavailable."
::= { cpqHoIfPhysMapEntry 5 }
cpqHoIfPhysMapMemBaseAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The base memory address used by this physical hardware
interface. The number zero (0) indicates that this device does
not use system memory or this information is unavailable."
::= { cpqHoIfPhysMapEntry 6 }
cpqHoIfPhysMapPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The port number of the interface for multi-port NICs.
A port number of -1 indicates that the port could not
be determined."
::= { cpqHoIfPhysMapEntry 7 }
cpqHoIfPhysMapDuplexState OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- default
half(2),
full(3)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This variable describes the configured duplex state of the NIC."
::= { cpqHoIfPhysMapEntry 8 }
cpqHoIfPhysMapCondition OBJECT-TYPE
SYNTAX INTEGER
{
other(1), -- default
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The condition of this interface."
::= { cpqHoIfPhysMapEntry 9 }
cpqHoIfPhysMapOverallCondition OBJECT-TYPE
SYNTAX INTEGER
{
other(1), -- default
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The overall condition of all interfaces."
::= { cpqHoIfPhysMap 2 }
-- ****************************************************************************
-- Host OS Software Running Table
-- ==============================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoSWRunning Group (1.3.6.1.4.1.232.11.2.6)
-- cpqHoSWRunningTable (1.3.6.1.4.1.232.11.2.6.1)
-- cpqHoSwRunningTrapDesc (1.3.6.1.4.1.232.11.2.6.2)
--
--
-- The cpqHoSWRunning group contains configuration and status information
-- about the software running on the host OS.
--
-- Implementation of the cpqHoSWRunning group is optional for agents
-- that support the Host OS MIB.
--
-- ****************************************************************************
cpqHoSWRunningTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoSWRunningEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of descriptions of software running on the system."
::= { cpqHoSWRunning 1 }
cpqHoSWRunningEntry OBJECT-TYPE
SYNTAX CpqHoSWRunningEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a software program running on the system."
INDEX { cpqHoSWRunningIndex }
::= { cpqHoSWRunningTable 1 }
CpqHoSWRunningEntry ::= SEQUENCE {
cpqHoSWRunningIndex INTEGER,
cpqHoSWRunningName DisplayString,
cpqHoSWRunningDesc DisplayString,
cpqHoSWRunningVersion DisplayString,
cpqHoSWRunningDate OCTET STRING,
cpqHoSWRunningMonitor INTEGER,
cpqHoSWRunningState INTEGER,
cpqHoSWRunningCount INTEGER,
cpqHoSWRunningCountMin INTEGER,
cpqHoSWRunningCountMax INTEGER,
cpqHoSWRunningEventTime OCTET STRING,
cpqHoSWRunningStatus INTEGER,
cpqHoSWRunningConfigStatus INTEGER,
cpqHoSWRunningIdentifier DisplayString,
cpqHoSWRunningRedundancyMode INTEGER
}
cpqHoSWRunningIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoSWRunningEntry 1 }
cpqHoSWRunningName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the software."
::= { cpqHoSWRunningEntry 2 }
cpqHoSWRunningDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the software."
::= { cpqHoSWRunningEntry 3 }
cpqHoSWRunningVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the software.
This field will be a null (size 0) string if the agent cannot
provide the software version."
::= { cpqHoSWRunningEntry 4 }
cpqHoSWRunningDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the software date. The hour, minute, and second field will be
set to zero (0) if they are not relevant."
::= { cpqHoSWRunningEntry 5 }
cpqHoSWRunningMonitor OBJECT-TYPE
SYNTAX INTEGER
{
other(1), -- default
start(2),
stop(3),
startAndStop(4),
count(5),
startAndCount(6),
countAndStop(7),
startCountAndStop(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user specified monitor option for a process."
::= { cpqHoSWRunningEntry 6 }
cpqHoSWRunningState OBJECT-TYPE
SYNTAX INTEGER
{
other(1), -- default
started(2),
stopped(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of monitored process."
::= { cpqHoSWRunningEntry 7 }
cpqHoSWRunningCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"For each process name, the number of instances of the process running on the system is
kept count of, in this variable."
::= { cpqHoSWRunningEntry 8 }
cpqHoSWRunningCountMin OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS optional
DESCRIPTION
"This is the lower threshold on cpqHoSWRunningCount to be set by the user."
::= { cpqHoSWRunningEntry 9 }
cpqHoSWRunningCountMax OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS optional
DESCRIPTION
"This is the upper threshold on cpqHoSWRunningCount to be set by the user."
::= { cpqHoSWRunningEntry 10 }
cpqHoSWRunningEventTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS optional
DESCRIPTION
"The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred.
field octets contents range
===== ====== ======== =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
The hour, minute, and second field will be set to zero (0) if they are not relevant."
::= { cpqHoSWRunningEntry 11 }
cpqHoSWRunningStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
normal(2),
warning(3),
minor(4),
major(5),
critical(6),
disabled(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The overall alarm state of the resources managed by the software, or the software itself."
::= { cpqHoSWRunningEntry 12 }
cpqHoSWRunningConfigStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
starting(2),
initialized(3),
configured(4),
operational(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The configuration state of the software. The level of initialization the software has performed."
::= { cpqHoSWRunningEntry 13 }
cpqHoSWRunningIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The unique identifier of the sofware. This identifier should be unique for all instances of the sofware running in the environment."
::= { cpqHoSWRunningEntry 14 }
cpqHoSWRunningRedundancyMode OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
master(2),
backup(3),
slave(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"When the software is running in a high availability mode, the failover mode of this instance of the software."
::= { cpqHoSWRunningEntry 15 }
cpqHoSwRunningTrapDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The error message for a process monitor event."
::= { cpqHoSWRunning 2 }
-- ****************************************************************************
-- Config Software Version Instrumentation Group
-- ===============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoSwVer Group (1.3.6.1.4.1.232.11.2.7)
-- cpqHoSwVerTable (1.3.6.1.4.1.232.11.2.7.2)
-- cpqHoSwVerAgentsVer (1.3.6.1.4.1.232.11.2.7.3)
--
-- The cpqSwVer group describes the software version table.
--
-- Implementation of the cpqSwVer group is mandatory for all
-- agents that support the Host MIB.
--
-- The read-write elements of this table should be saved from instance to
-- instance of the agent.
--
-- This table can be added to by writing to the cpqHoSwVerName (using the
-- cpqHoSwVerNextIndex index) field with a new driver name. Writing to
-- this field causes the creation of a new table row (and any data that can
-- be obtained will be filled in, the remainder will be set to the defaults.)
--
-- A row may be deleted by writing to the cpqHoSwVerName field with a null
-- entry.
-- ****************************************************************************
cpqHoSwVerNextIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the next available entry in the cpqHoSwVer
table. If the maximum number of entries to the cpqHoSwVer
table has been reached, this index will contain -1."
--
-- Writing to the cpqHoSwVerName variable using this index will cause a new
-- entry in the table to be created.
--
::= { cpqHoSwVer 1 }
cpqHoSwVerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoSwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of software item entries."
::= { cpqHoSwVer 2 }
cpqHoSwVerEntry OBJECT-TYPE
SYNTAX CpqHoSwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of software items that are on the machine."
INDEX { cpqHoSwVerIndex }
::= { cpqHoSwVerTable 1 }
CpqHoSwVerEntry ::= SEQUENCE {
cpqHoSwVerIndex INTEGER,
cpqHoSwVerStatus INTEGER,
cpqHoSwVerType INTEGER,
cpqHoSwVerName DisplayString,
cpqHoSwVerDescription DisplayString,
cpqHoSwVerDate OCTET STRING,
cpqHoSwVerLocation DisplayString,
cpqHoSwVerVersion DisplayString,
cpqHoSwVerVersionBinary DisplayString
}
cpqHoSwVerIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies an entry in the
cpqHoSwVer table."
::= { cpqHoSwVerEntry 1 }
cpqHoSwVerStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined (default)
loaded(2), -- and running
notloaded(3) -- found but not loaded
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status for the software item."
--
-- Items of type 'other' are those items which the agent could
-- not locate.
--
::= { cpqHoSwVerEntry 2 }
cpqHoSwVerType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
driver(2), -- (default)
agent(3),
sysutil(4),
application(5),
keyfile(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of software item."
::= { cpqHoSwVerEntry 3 }
cpqHoSwVerName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of this software item."
--
-- Writing to this entry with an index equal to cpqHoSwVerNextIndex
-- causes a table row to be created, and all entries to be filled in.
--
-- Writing to this entry with a NULL name deletes the current row.
--
::= { cpqHoSwVerEntry 4 }
cpqHoSwVerDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The description of this software item."
--
-- A length of 0 indicates that the description of this item is
-- not available.
--
-- Writing to this entry can cause the entire row to be updated.
--
::= { cpqHoSwVerEntry 5 }
cpqHoSwVerDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date of the software item, if any.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65535
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
The year field is set with the most significant octet first.
An entry of zero (0) means that there is no date associated with
this software item. Zero is the default."
::= { cpqHoSwVerEntry 6 }
cpqHoSwVerLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The location of this software item on the server."
::= { cpqHoSwVerEntry 7 }
cpqHoSwVerVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An string that specifies the version of this item."
::= { cpqHoSwVerEntry 8 }
cpqHoSwVerVersionBinary OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An string that specifies the version of this item based on
the binary version resource."
::= { cpqHoSwVerEntry 9 }
--
-- New for release 7.10: cpqHoSwVerAgentsVer
--
cpqHoSwVerAgentsVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string that specifies the version of the Insight
Management Agents running on the system."
::= { cpqHoSwVer 3 }
-- ****************************************************************************
-- The cpqHoGeneric group holds only the generic trap
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoGeneric Group (1.3.6.1.4.1.232.11.2.8)
--
-- Implementation of this group is optional.
--
-- ****************************************************************************
cpqHoGenericData OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Data for the generic trap."
--
-- This is the data variable that is sent with the generic trap below.
--
-- Writing to this variable will cause the generic trap to be sent with
-- the newly written data.
--
::= { cpqHoGeneric 1 }
cpqHoCriticalSoftwareUpdateData OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..512))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Data for the Critical Software Update trap."
--
-- This is the data variable that is sent with the Critical Software
-- update Notification Trap below.
-- Writing to this variable will cause the Critical Software update Notification Trap
-- to be sent with the newly written data.
--
::= { cpqHoGeneric 2 }
-- ****************************************************************************
-- Software Performance Group
-- ===========================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoSwPerf Group (1.3.6.1.4.1.232.11.2.9)
--
-- Implementation of this group is optional.
--
-- ****************************************************************************
cpqHoSwPerfAppErrorDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" This string holds error information about the last application
error that occurred in the system. "
::= { cpqHoSwPerf 1 }
-- ****************************************************************************
-- System Status Group
-- ===================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoSystemStatus Group (1.3.6.1.4.1.232.11.2.10)
--
-- Implementation of this group is mandatory.
--
-- ****************************************************************************
cpqHoMibStatusArray OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MIB Status Array is an array of MIB status structures. Each
structure is made up of 4 octets. The first octet is the MIB
presence. The second octet is MIB condition. The third octet is
MIB major revision. The fourth octet is MIB minor revision. These
blocks of 4 octets each are index by the mib identifier just after
the compaq enterprise (eg in 1.3.6.1.232.11 mib, the index is 11).
The 4 octets in the first block (block 0) are reserved for systems
management and serve as an aggregate of the other mibs.
Array element 0 is the status for all MIBs in the Compaq
Enterprise. Array element n, where n > 0, is the status for the
nth MIB in the Compaq Enterprise (.1.3.6.1.4.1.232.n).
Octet Element Field
======== ======= =========
0 0 Status of any Compaq MIBs
1 Condition of all Compaq MIBs
2 System Flags (see below)
3 Detailed type (see below)
4 1 Status of Compaq MIB 1
5 Condition of Compaq MIB 1
6 Major Revision of Compaq MIB 1
7 Minor Revision of Compaq MIB 1
8 2 Status of Compaq MIB 2
9 Condition of Compaq MIB 2
10 Major Revision of Compaq MIB 2
11 Minor Revision of Compaq MIB 2
. .
.
.
n*4 n Status of Compaq MIB n
(n*4)+1 Condition of Compaq MIB n
(n*4)+2 Major Revision of Compaq MIB n
(n*4)+3 Minor Revision of Compaq MIB n
System Flags (octet 2)
Bit Meaning
===== =========
0 Equals 1 if the device is not a server, see detailed type below
Equals 0 if the device is a server
1 This system contains enabled remote console
functionality.
2 This system is configured to be an Integration Server.
3 Web Based Management is enabled.
4-7 Reserved (reserved Bits should be zero)
Detailed Type (octet 3)
Bits 0-4 Detailed Type, only used if bit 0 in octet 2 is 1.
Bits 5-7 Reserved for expansion. note, use these last in case we
need more then 32 types someday.
Type Values for Bits 0-4 (maps to CIM7 types)
Unknown = 0
Server = 1 (yes a duplicate of the server flag)
Desktop = 2
Workstation = 3
Portable = 4
Router = 5
Cluster = 6
Printer = 7
Switch = 8 (network switch)
Repeater = 9
Remote Access Device = 10
Other = 11
Management Processor = 12 (rib, RILOE, iLo)
Rack = 13
Enclosure = 14
KVM Switch = 15 (IP enabled keyboard video mouse switch).
UPS = 16
Power Distribution Unit = 17
Environmental Monitor = 18 (eg CMC)
Power Distribution Rack = 19 (PDR)
Storage Device = 20
For all other blocks, they are defined as:
Status This is a collection of flags. Each bit has the
following meaning when it is on (1):
Bit 2-7: RESERVED: Always 0
Bit 1: MIB is from offline data (only applies
to global system status)
Bit 0: MIB is available
NOTE: bit 7 is the most significant bit, bit 0
is the least significant.
Condition 0 - Not available
1 - Other
2 - OK
3 - Degraded
4 - Failed
Major Revision 0..255, where 0 is not available
Minor Revision 0..255, where 0 is not available"
::= { cpqHoSystemStatus 1 }
cpqHoConfigChangedDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time when the agents were last loaded.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date/time. The year field is set with the most significant
octet first."
::= { cpqHoSystemStatus 2 }
cpqHoGUID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16..17))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The globally unique identifier of this physical server.
If the OS cannot determine a unique ID, it will default the
variable to contain all 0's. The management station can then
perform a SET to this variable to provide the unique ID.
When the system is cellular, it will have its partition number
appended at the end."
::= { cpqHoSystemStatus 3 }
cpqHoCodeServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This item indicates how many code server shares are currently
configured on the system. If the value of this attribute is
0, this server has not been configured with code server shares."
::= { cpqHoSystemStatus 4 }
cpqHoWebMgmtPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This item indicates the port used by the Insight Web Agent.
If the port cannot be determined or the Web Management agent
is not enabled, this value will be -1."
::= { cpqHoSystemStatus 5 }
cpqHoGUIDCanonical OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (32..36))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The globally unique identifier in canonical format of this
physical server. If the OS cannot determine a unique ID, it will
default the variable to blank."
::= { cpqHoSystemStatus 6 }
cpqHoMibHealthStatusArray OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MIB Health Status Array is an array of status values representing an
overall status in element 0 follwed by server and storage status values as follows:
Octet Element Field
======== ======= =========
0 0 Aggregated Status of array elements
1 1 Status of element 1
2 2 Status of element 2
.
.
.
n n Status of element n
Status 0 - Not available
1 - Other
2 - OK
3 - Degraded
4 - Failed
.
.
Mibs are assigned an array element as follows. New items are added at the end.
0 - System Health Status (overall status as reported by who is reporting (agents or iLO))
1 - Total Aggregate (Includes IML Status)
2 - Processors (TBD 232.1.2.2.4:cpqSeCpuCondition)
3 - Memory (232.6.2.14.4:cpqHeResilientMemCondition)
4 - Cooling (232.6.2.6.4:cpqHeThermalSystemFanStatus)
5 - Sensors (232.6.2.6.3:cpqHeThermalTempStatus)
6 - Power (232.6.2.9.1:cpqHeFltTolPwrSupplyCondition)
7 - ProLiant Logs (232.6.2.11.2:cpqHeEventLogCondition)
8 - ASR (232.6.2.5.17:cpqHeAsrCondition)
9 - Drive Array (232.3.1.3:cpqDaMibCondition)
10 - SCSI (232.5.1.3:cpqScsiMibCondition)
11 - Storage Enclosures (232.8.1.3:cpqSsMibCondition)
12 - IDE (232.14.1.3:cpqIdeMibCondition)
13 - FC (232.16.1.3:cpqFcaMibCondition)
14 - Networks (232.18.1.3:cpqNicMibCondition)
15 - MP (232.9.1.3:cpqSm2MibCondition)
16 - HW/BIOS (232.6.2.16.1:cpqHeHWBiosCondition)
17 - Battery (232.6.2.17.1:cpqHeSysBackupBatteryCondition)"
::= { cpqHoSystemStatus 7 }
-- ****************************************************************************
-- Trap Info Group
-- ================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoTrapInfo Group (1.3.6.1.4.1.232.11.2.11)
--
-- Implementation of this group is mandatory.
--
-- ****************************************************************************
cpqHoTrapFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Trap Flags.
This is a collection of flags used during trap delivery.
Each bit has the following meaning:
Bit 5-31: RESERVED: Always 0.
Bit 2-4: Trap Condition
0 = Not used (for backward compatibility)
1 = Condition unknown or N/A
2 = Condition ok
3 = Condition degraded
4 = Condition failed
5-7 = reserved
Bit 1: Client IP address type
0 = static entry
1 = DHCP entry
Bit 0: Agent Type
0 = Server
1 = Client
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant."
::= { cpqHoTrapInfo 1 }
-- ****************************************************************************
-- OS Client Table
-- ====================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
--- cpqHoClient Group (1.3.6.1.4.1.232.11.2.12)
--
-- The cpqHoClient table contains entries describing identification,
-- address, and status information about each unit that is using
-- services provided by this unit.
--
-- ****************************************************************************
cpqHoClientLastModified OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time of the last modification to the client table.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to all 0's if there are no entries to the
client table.
The year field will be set to 0xFFFF if the agent does not support
the client table.
The year field is set with the most significant octet first."
::= { cpqHoClients 1 }
cpqHoClientDelete OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this variable to the name of a client in the client table
will cause that row in the table to be deleted. Any other set
will fail.
Note that the indices of the table will (most likely) be renumbered
following a deletion."
::= { cpqHoClients 2 }
cpqHoClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of client descriptions."
::= { cpqHoClients 3 }
cpqHoClientEntry OBJECT-TYPE
SYNTAX CpqHoClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A client description."
INDEX { cpqHoClientIndex }
::= { cpqHoClientTable 1 }
CpqHoClientEntry ::= SEQUENCE {
cpqHoClientIndex INTEGER,
cpqHoClientName DisplayString,
cpqHoClientIpxAddress OCTET STRING,
cpqHoClientIpAddress IpAddress,
cpqHoClientCommunity DisplayString,
cpqHoClientID OCTET STRING
}
cpqHoClientIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoClientEntry 1 }
cpqHoClientName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Win95 machine name of this client."
-- Note that Win95 limits the machine name to a maximum of 15 characters.
::= { cpqHoClientEntry 2 }
cpqHoClientIpxAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPX address for this client, all octets should be set to
0xff if this machine does not support IPX.
The format is NetAddr:NodeNumber and sent in MSB order:
1111111111
01234567:890123456789"
-- Note, this item is still in definition and probably will change.
::= { cpqHoClientEntry 3 }
cpqHoClientIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address for this client, all octets should be set to
0xff if this machine does not support IP. The order will be
in network byte order (ie MSB first.)"
::= { cpqHoClientEntry 4 }
cpqHoClientCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A community name that can be used to query the client with SNMP.
This community name should have, but is not required to have,
the greatest possible access to client information."
::= { cpqHoClientEntry 5 }
cpqHoClientID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identifier of this client."
::= { cpqHoClientEntry 6 }
-- ****************************************************************************
-- OS Memory Group
-- ===============
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
--- cpqHoMemory Group (1.3.6.1.4.1.232.11.2.13)
--
-- The cpqHoMemory group contains entries describing memory
-- as seen by the OS.
--
-- ****************************************************************************
cpqHoPhysicalMemorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total amount of physical memory as seen by the OS (in megabytes).
A -1 will be returned if this value could not be determined."
::= { cpqHoMemory 1 }
cpqHoPhysicalMemoryFree OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of free physical memory (in megabytes).
A -1 will be returned if this value could not be determined."
::= { cpqHoMemory 2 }
cpqHoPagingMemorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total virtual memory available from the OS (in megabytes).
A -1 will be returned if this value could not be determined."
::= { cpqHoMemory 3 }
cpqHoPagingMemoryFree OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Available paging memory (in megabytes).
A -1 will be returned if this value could not be determined."
::= { cpqHoMemory 4 }
cpqHoBootPagingFileSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The paging file size of the boot volume in the format xxxMB or
xxxGB, where xxx is the paging file size in that unit shown right
after it.
NULL value will be returned if this value could not be determined."
::= { cpqHoMemory 5 }
cpqHoBootPagingFileMinimumSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum paging file size of the boot volume required to save the
memory dump in the event of a system crash. The format is xxxMB or
xxxGB, where xxx is the minimum paging file size in that unit shown
right after it."
::= { cpqHoMemory 6 }
cpqHoBootPagingFileVolumeFreeSpace OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS optional
DESCRIPTION
"Free space of the boot volume required to save the memory dump in the
event of a system crash. The format is xxxMB or xxxGB, where xxx is
the minimum paging file size in that unit shown right after it."
::= { cpqHoMemory 7 }
-- ****************************************************************************
-- Firmware Version Instrumentation Group
-- ======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoFwVer Group (1.3.6.1.4.1.232.11.2.14)
-- cpqHoFwVerTable (1.3.6.1.4.1.232.11.2.14.1)
--
-- The cpqHoFwVer group describes the firmware version table.
--
-- Implementation of the cpqHoFwVer group is mandatory for all
-- agents that support the Host MIB.
--
-- ****************************************************************************
cpqHoFwVerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoFwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of firmware item entries."
::= { cpqHoFwVer 1 }
cpqHoFwVerEntry OBJECT-TYPE
SYNTAX CpqHoFwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of firmware items that are on the machine."
INDEX { cpqHoFwVerIndex }
::= { cpqHoFwVerTable 1 }
CpqHoFwVerEntry ::= SEQUENCE {
cpqHoFwVerIndex INTEGER,
cpqHoFwVerCategory INTEGER,
cpqHoFwVerDeviceType INTEGER,
cpqHoFwVerDisplayName DisplayString,
cpqHoFwVerVersion DisplayString,
cpqHoFwVerLocation DisplayString,
cpqHoFwVerXmlString DisplayString,
cpqHoFwVerKeyString DisplayString,
cpqHoFwVerUpdateMethod INTEGER
}
cpqHoFwVerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Index.
The firmware version index uniquely identifies an entry in the
cpqHoFwVer table."
::= { cpqHoFwVerEntry 1 }
cpqHoFwVerCategory OBJECT-TYPE
SYNTAX INTEGER {
other(1),
storage(2),
nic(3),
rib(4),
system(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Category."
::= { cpqHoFwVerEntry 2 }
cpqHoFwVerDeviceType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
internalArrayController(2),
fibreArrayController(3),
scsiController(4),
fibreChannelTapeController(5),
modularDataRouter(6),
ideCdRomDrive(7),
ideDiskDrive(8),
scsiCdRom-ScsiAttached(9),
scsiDiskDrive-ScsiAttached(10),
scsiTapeDrive-ScsiAttached(11),
scsiTapeLibrary-ScsiAttached(12),
scsiDiskDrive-ArrayAttached(13),
scsiTapeDrive-ArrayAttached(14),
scsiTapeLibrary-ArrayAttached(15),
scsiDiskDrive-FibreAttached(16),
scsiTapeDrive-FibreAttached(17),
scsiTapeLibrary-FibreAttached(18),
scsiEnclosureBackplaneRom-ScsiAttached(19),
scsiEnclosureBackplaneRom-ArrayAttached(20),
scsiEnclosureBackplaneRom-FibreAttached(21),
scsiEnclosureBackplaneRom-ra4x00(22),
systemRom(23),
networkInterfaceController(24),
remoteInsightBoard(25),
sasDiskDrive-SasAttached(26),
sataDiskDrive-SataAttached(27),
usbController(28),
sasControllerAdapter(29),
sataControllerAdapter(30),
systemDevice(31),
fibreChannelHba(32),
convergedNetworkAdapter(33),
ideController(34)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Device Type."
::= { cpqHoFwVerEntry 3 }
cpqHoFwVerDisplayName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Device Display Name.
This is the display name of the device containing the firmware."
::= { cpqHoFwVerEntry 4 }
cpqHoFwVerVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version.
This is the version of the device firmware."
::= { cpqHoFwVerEntry 5 }
cpqHoFwVerLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Device Location.
This is a printable string that specifies the location of the
device that contains the firmware."
::= { cpqHoFwVerEntry 6 }
cpqHoFwVerXmlString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Xml String.
This is an XML string that specifies the location of the device
that contains the firmware.
This will be NULL string (size 0) if this information could not
be provided."
::= { cpqHoFwVerEntry 7 }
cpqHoFwVerKeyString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version Key String.
This field is differentiate devices of the same type."
::= { cpqHoFwVerEntry 8 }
cpqHoFwVerUpdateMethod OBJECT-TYPE
SYNTAX INTEGER {
other(1),
noUpdate(2),
softwareflash(3),
replacePhysicalRom(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version update method."
::= { cpqHoFwVerEntry 9 }
-- ****************************************************************************
-- Hardware Information Group
-- ======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOs Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqHoHWInfo Group (1.3.6.1.4.1.232.11.2.15)
-- cpqHoHWInfoPlatform (1.3.6.1.4.1.232.11.2.15.1)
--
-- The cpqHoHWInfo group describes some hw information necessary to other agents.
--
-- Implementation of the cpqHoHWInfo group is optional for
-- agents that support the Host MIB.
--
-- ****************************************************************************
cpqHoHWInfoPlatform OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
cellular(2),
foundation(3),
virtualMachine(4),
serverBlade(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Hardware platform type.
This object represents the platform type of the server's host
system represented by this MIB."
::= { cpqHoHWInfo 1 }
-- ****************************************************************************
-- The cpqPwrThreshold group holds data for the
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqHostOS Group (1.3.6.1.4.1.232.11)
-- cpqHoComponent Group (1.3.6.1.4.1.232.11.2)
-- cpqPwrThreshold Group (1.3.6.1.4.1.232.11.2.16)
--
-- Implementation of this group is mandatory.
--
-- ****************************************************************************
cpqPwrWarnType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of power reading on which the warning is based."
::= { cpqPwrThreshold 1 }
cpqPwrWarnThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold the power usage must exceed (in Watts)."
::= { cpqPwrThreshold 2 }
cpqPwrWarnDuration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Duration that power usage must be exceeded before warning (in minutes)."
::= { cpqPwrThreshold 3 }
cpqSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Serial number of the server."
::= { cpqPwrThreshold 4 }
cpqServerUUID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server UUID"
::= { cpqPwrThreshold 5 }
-- ****************************************************************************
-- Host MIB Trap Definitions
-- =========================
--
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
--
-- Trap support in an SNMP agent implementation is optional. An SNMP
-- agent implementation may support all, some, or none of the traps.
-- If traps are supported, The user should be provided with the option of
-- disabling traps.
--
-- Implementation of cpqHoGenericTrap is a mandatory part of the Generic
-- group.
--
-- **************************************************************************
cpqHoGenericTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { cpqHoGenericData }
DESCRIPTION
-- This trap is a generic trap, and left undefined.
"Generic trap."
--#TYPE "Generic trap (11001)"
--#SUMMARY "%s"
--#ARGUMENTS {0}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 11001
cpqHoAppErrorTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { cpqHoSwPerfAppErrorDesc }
DESCRIPTION
"An application has generated an exception. Specific
error information is contained in the variable
cpqHoSwPerfAppErrorDesc."
--#TYPE "Application Error Trap (11002)"
--#SUMMARY "%s"
--#ARGUMENTS {0}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 11002
cpqHo2GenericTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoGenericData }
DESCRIPTION
-- This trap is a generic trap, and left undefined.
"Generic trap."
--#TYPE "Generic trap (11003)"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11003
cpqHo2AppErrorTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSwPerfAppErrorDesc }
DESCRIPTION
"An application has generated an exception. Specific
error information is contained in the variable
cpqHoSwPerfAppErrorDesc."
--#TYPE "Application Error Trap (11004)"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11004
cpqHo2NicStatusOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the OK condition."
--#TYPE "Status Trap (11005)"
--#SUMMARY "NIC Status is OK for slot %s."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 11005
cpqHo2NicStatusFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the Failed condition."
--#TYPE "Status Trap (11006)"
--#SUMMARY "NIC Status is Failed for slot %s."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 11006
cpqHo2NicSwitchoverOccurred TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the configured redundant NIC
becomes the active NIC."
--#TYPE "Status Trap (11007)"
--#SUMMARY "NIC switchover to slot %s from slot %s."
--#ARGUMENTS {2, 3}
--#SEVERITY MAJOR
--#TIMEINDEX 99
::= 11007
cpqHo2NicStatusOk2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the OK condition."
--#TYPE "Status Trap (11008)"
--#SUMMARY "NIC status is ok for slot %s, port %s."
--#ARGUMENTS {2, 3}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY OK
--#HWSTATUS_CATEGORY NETWORK
::= 11008
cpqHo2NicStatusFailed2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the Failed condition."
--#TYPE "Status Trap (11009)"
--#SUMMARY "NIC status is failed for slot %s, port %s."
--#ARGUMENTS {2, 3}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NETWORK
--#ACTION "Check the network cables. Replace the failed NIC."
::= 11009
cpqHo2NicSwitchoverOccurred2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort }
DESCRIPTION
"This trap will be sent any time the configured redundant NIC
becomes the active NIC."
--#TYPE "Status Trap (11010)"
--#SUMMARY "NIC switchover to slot %s, port %s from slot %s, port %s."
--#ARGUMENTS {2, 3, 4, 5}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NETWORK
--#ACTION "Examine the network connections and check for a NIC failure."
::= 11010
cpqHoProcessEventTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSwRunningTrapDesc }
DESCRIPTION
"A monitored process has either started or stopped running."
--#TYPE "Process Monitor Event Trap (11011)"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11011
cpqHoProcessCountWarning TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSWRunningName, cpqHoSWRunningCount,
cpqHoSWRunningCountMin, cpqHoSWRunningCountMax,
cpqHoSWRunningEventTime }
DESCRIPTION
"A monitored process count has violated the thresholds set on cpqHoSWRunningCount"
--#TYPE "Process Count Event Trap (11012)"
--#SUMMARY "Process %s has count %s which violates the thresholds %s to %s."
--#ARGUMENTS {2, 3, 4, 5}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11012
cpqHoProcessCountNormal TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSWRunningName, cpqHoSWRunningCount,
cpqHoSWRunningCountMin, cpqHoSWRunningCountMax,
cpqHoSWRunningEventTime }
DESCRIPTION
"A monitored process count has returned back to normal."
--#TYPE "Process Monitor Event Trap (11013)"
--#SUMMARY "Process %s has count %s which respects the thresholds %s to %s."
--#ARGUMENTS {2, 3, 4, 5}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
--#SIMPLE_SEVERITY OK
--#HWSTATUS_CATEGORY NONE
::= 11013
cpqHoCriticalSoftwareUpdateTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoCriticalSoftwareUpdateData }
DESCRIPTION
"This trap is a send to the user to notify him of a Critical Software Update."
--#TYPE "Critical Software update Notification Trap (11014)"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#SIMPLE_SEVERITY CRITICAL
--#HWSTATUS_CATEGORY NONE
--#ACTION "Install the required software updates."
::= 11014
cpqHoCrashDumpNotEnabledTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoCrashDumpState }
DESCRIPTION
"This trap is sent to the user to notify him that the Crash Dump is not enabled.
This trap is not sent if cpqHoCrashDumpMonitoring is disabled."
--#TYPE "Crash Dump not enabled Notification Trap (11015)"
--#SUMMARY "Crash dump is not enabled."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11015
cpqHoBootPagingFileTooSmallTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoCrashDumpState, cpqHoBootPagingFileSize, cpqHoBootPagingFileMinimumSize }
DESCRIPTION
"This trap is sent when the paging file size of the boot volume or the target volume of the memory dump file is too small to hold a crash dump.
This trap is not sent if cpqHoCrashDumpMonitoring is disabled."
--#TYPE "Boot Paging File Or Memory Dump Target Volume Too Small Notification Trap (11016)"
--#SUMMARY "The paging file size of the boot volume (%s) or the target volume of the memory dump file is not large enough to hold a crash dump in the event of a system crash (%s)."
--#ARGUMENTS {3, 4}
--#SEVERITY WARNING
--#TIMEINDEX 99
::= 11016
cpqHoSWRunningStatusChangeTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSWRunningName, cpqHoSWRunningDesc,cpqHoSwRunningTrapDesc, cpqHoSWRunningVersion,cpqHoSWRunningStatus, cpqHoSWRunningConfigStatus, cpqHoSWRunningIdentifier, cpqHoSWRunningRedundancyMode }
DESCRIPTION
"This trap notifies the user that the running software has changed status, configuration status, or redundancy mode."
--#TYPE "Software status change Notification Trap (11017)"
--#SUMMARY "Software status change for %s, description = %s, id = %s"
--#ARGUMENTS {2, 4, 8}
--#SEVERITY WARNING
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11017
cpqHo2PowerThresholdTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqPwrWarnType, cpqPwrWarnThreshold, cpqPwrWarnDuration, cpqSerialNum, cpqServerUUID }
DESCRIPTION
-- This trap notifies user of a power threshold breach.
"Power threshold exceeded."
--#TYPE "Power Threshold Exceeded (11018)"
--#SUMMARY "Power threshold has been exceeded (Warning Type: %s, Threshold: %d watts, Duration: %d minutes)"
--#ARGUMENTS {2, 3, 4}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY POWER
::= 11018
cpqHoBootPagingFileOrFreeSpaceTooSmallTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoCrashDumpState, cpqHoBootPagingFileSize, cpqHoBootPagingFileVolumeFreeSpace, cpqHoBootPagingFileMinimumSize }
DESCRIPTION
"This trap is sent when the paging file size of the boot volume or the free space of memory dump target volume is too small to hold a crash dump."
--#TYPE "Boot Paging File Or Memory Dump Target Volume Too Small Notification Trap (11016)"
--#SUMMARY "The paging file size of the boot volume (%s) or the free space of the memory dump target volume (%s) is not large enough to hold a crash dump in the event of a system crash (%s)."
--#ARGUMENTS {3, 4, 5}
--#SEVERITY WARNING
--#TIMEINDEX 99
--#SIMPLE_SEVERITY MAJOR
--#HWSTATUS_CATEGORY NONE
::= 11019
cpqHoMibHealthStatusArrayChangeTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoMibHealthStatusArray }
DESCRIPTION
"A change in the cpqHoMibHealthStatusArray has occurred."
--#TYPE "Health Status Array Change occurred (11020)"
--#SUMMARY "A change in the health status of the server has occurred, the status is now %s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#SIMPLE_SEVERITY OK
--#HWSTATUS_CATEGORY MANAGEMENTPROCESSOR
::= 11020
END