mibs/MIBS/hp/HP-PROCURVE-420-PRIVATE-MIB

1186 lines
44 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- Copyright 2003 hP, Inc.
-- All rights reserved.
-- Copyright message need to be updated
HP-PROCURVE-420-PRIVATE-MIB
DEFINITIONS ::= BEGIN
IMPORTS
ifIndex FROM RFC1213-MIB
mgmt, Counter, IpAddress, enterprises FROM RFC1155-SMI
-- Integer32, Counter32 FROM SNMPv2-SMI
;
PhysAddress
::= OCTET STRING
Guage32
::= Counter
MacAddress
::= OCTET STRING
DisplayString
::= OCTET STRING
TruthValue ::=
INTEGER { false(2), true(1) }
-- Before we get the private mib OID from hP, using the accton OID instead
hP OBJECT IDENTIFIER ::= { enterprises 11 }
wireless OBJECT IDENTIFIER ::= { hP 2 }
enterprise OBJECT IDENTIFIER ::= { wireless 3 }
accessPoint OBJECT IDENTIFIER ::= { enterprise 7 }
proCurve OBJECT IDENTIFIER ::= { accessPoint 11 }
hPProCuve420 OBJECT IDENTIFIER ::= { proCurve 37 }
-- accton AP OBJECT IDs Groups
enterpriseApSys OBJECT IDENTIFIER ::= { hPProCuve420 1 }
enterpriseApLineMgnt OBJECT IDENTIFIER ::= { hPProCuve420 2 }
enterpriseApPortMgnt OBJECT IDENTIFIER ::= { hPProCuve420 3 }
enterpriseApFileTransferMgt OBJECT IDENTIFIER ::= { hPProCuve420 4 }
enterpriseApResetMgt OBJECT IDENTIFIER ::= { hPProCuve420 5 }
enterpriseApIpMgt OBJECT IDENTIFIER ::= { hPProCuve420 6 }
enterpriseAPdot11 OBJECT IDENTIFIER ::= { hPProCuve420 7 }
-- ****************************************************************************************
-- enterpriseApSys - Standard Mib elements
-- ****************************************************************************************
swHardwareVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hardware version of the main board."
::= { enterpriseApSys 1 }
swBootRomVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Boot ROM code version of the main board."
::= { enterpriseApSys 2 }
swOpCodeVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Operation code version of the main board."
::= { enterpriseApSys 3 }
swCountryCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
ACCESS read-write
STATUS mandatory
DESCRIPTION "Country code of the AP.
AL-ALBANIA, DZ-ALGERIA, AR-ARGENTINA, AM-ARMENIA, AU-AUSTRALIA, AT-AUSTRIA, AZ-AZERBAIJAN,
BH-BAHRAIN, BY-BELARUS, BE-BELGIUM, BZ-BELIZE, BO-BOLVIA, BR-BRAZIL, BN-BRUNEI_DARUSSALAM,
BG-BULGARIA, CA-CANADA, CL-CHILE, CN-CHINA, CO-COLOMBIA, CR-COSTA_RICA, HR-CROATIA,
CY-CYPRUS, CZ-CZECH_REPUBLIC, DK-DENMARK, DO-DOMINICAN_REPUBLIC, EC-ECUADOR,
EG-EGYPT, EE-ESTONIA, FI-FINLAND, FR-FRANCE, GE-GEORGIA, DE-GERMANY, GR-GREECE,
GT-GUATEMALA, HK-HONG_KONG, HU-HUNGARY, IS-ICELAND, IN-INDIA, ID-INDONESIA, IR-IRAN,
IE-IRELAND, IL-ISRAEL, IT-ITALY, JP-JAPAN, JO-JORDAN, KZ-KAZAKHSTAN, KP-NORTH_KOREA,
KR-KOREA_REPUBLIC, KW-KUWAIT, LV-LATVIA, LB-LEBANON, LI-LIECHTENSTEIN,
LT-LITHUANIA, LU-LUXEMBOURG, MO-MACAU, MK-MACEDONIA, MY-MALAYSIA, MX-MEXICO, MC-MONACO,
MA-MOROCCO, NA-NORTH_AMERICA, NL-NETHERLANDS, NZ-NEW_ZEALAND, NO-NORWAY, OM-OMAN, PK-PAKISTAN,
PA-PANAMA, PE-PERU, PH-PHILIPPINES, PL-POLAND, PT-PORTUGAL, PR-PUERTO_RICO, QA-QATAR,
RO-ROMANIA, RU-RUSSIA, SA-SAUDI_ARABIA, SG-SINGAPORE, SK-SLOVAK_REPUBLIC, SI-SLOVENIA,
ZA-SOUTH_AFRICA, ES-SPAIN, SE-SWEDEN, CH-SWITZERLAND, SY-SYRIA, TW-TAIWAN, TH-THAILAND,
TR-TURKEY, UA-UKRAINE, AE-UNITED_ARAB_EMIRATES, GB-UNITED_KINGDOM, US-UNITED_STATES,
UY-URUGUAY, VE-VENEZUELA, VN-VIETNAM"
::= { enterpriseApSys 4 }
-- ****************************************************************************************
-- enterpriseApLine AP Line elements
-- ****************************************************************************************
lineTable OBJECT-TYPE
SYNTAX SEQUENCE OF LineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each RS-232 line in this system"
::= { enterpriseApLineMgnt 1 }
lineEntry OBJECT-TYPE
SYNTAX LineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one RS232 line of the Access Point."
INDEX { lineIndex }
::= { lineTable 1 }
LineEntry ::= SEQUENCE
{
lineIndex Integer32,
lineDataBits Integer32,
lineParity INTEGER,
lineSpeed Integer32,
lineStopBits Integer32
}
lineIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This is defined as RS-232 index."
::= { lineEntry 1 }
lineDataBits OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is defined as number of data bits for the RS232 interface."
::= { lineEntry 2 }
lineParity OBJECT-TYPE
SYNTAX INTEGER
{
none(99),
odd(1),
even(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is defined as parity of the RS232 interface."
::= { lineEntry 3 }
lineSpeed OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is defined as the speed of the RS-232 interface."
::= { lineEntry 4 }
lineStopBits OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is defined as the number of stop bits for the RS-232 interface."
::= { lineEntry 5 }
-- ****************************************************************************************
-- enterpriseApPortMgnt - Port Mib elements
-- ****************************************************************************************
portTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each switch port (including expansion slot)
in this system. This table also contains information
about each trunk (similar to Cisco's EtherChannel)."
::= { enterpriseApPortMgnt 1 }
portEntry OBJECT-TYPE
SYNTAX PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one switch port of the switch."
INDEX { portIndex }
::= { portTable 1 }
PortEntry ::= SEQUENCE
{
portIndex Integer32,
portName DisplayString,
portType INTEGER,
portSpeedDpxCfg INTEGER,
portFlowCtrlCfg INTEGER,
portCapabilities INTEGER,
portAutonegotiation INTEGER,
portSpeedDpxStatus INTEGER,
portFlowCtrlStatus INTEGER
}
portIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This is defined as ifIndex in the IF-MIB."
::= { portEntry 1 }
portName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port name. This is same as
ifAlias in the IF-MIB (RFC2863 or later)."
::= { portEntry 2 }
portType OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
hundredBaseTX(2),
hundredBaseFX(3),
thousandBaseSX(4),
thousandBaseLX(5),
thousandBaseT(6),
thousandBaseGBIC(7),
thousandBaseMiniGBIC(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port type."
::= { portEntry 3 }
portSpeedDpxCfg OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
halfDuplex10(2),
fullDuplex10(3),
halfDuplex100(4),
fullDuplex100(5),
halfDuplex1000(6),
fullDuplex1000(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Set the port speed and duplex mode as follows:
halfDuplex10(2) - 10Mbps and half duplex mode
fullDuplex10(3) - 10Mbps and full duplex mode
halfDuplex100(4) - 100Mbps and half duplex mode
fullDuplex100(5) - 100Mbps and full duplex mode
halfDuplex1000(6) - 1000Mbps and half duplex mode
fullDuplex1000(7) - 1000Mbps and full duplex mode
hundredBaseTX port can be set as
halfDuplex10(2)
fullDuplex10(3)
halfDuplex100(4)
fullDuplex100(5)
hundredBaseFX port can be set as
halfDuplex100(4)
fullDuplex100(5)
thousandBaseSX port can be set as
halfDuplex1000(6)
fullDuplex1000(7)
The actual operating speed and duplex of the port
is given by portSpeedDpxStatus."
DEFVAL { halfDuplex10 }
::= { portEntry 4 }
portFlowCtrlCfg OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2),
backPressure(3),
dot3xFlowControl(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "(1) Flow control mechanism is enabled.
If the port type is hundredBaseTX or thousandBaseSX:
When the port is operating in halfDuplex mode, the
port uses backPressure flow control mechanism. When
the port is operating in fullDuplex mode, the port
uses IEEE 802.3x flow control mechanism.
If the port type is hundredBaseFX:
When the port is operating in halfDuplex mode, the
port uses backPressure flow control mechanism. When
the port is operating in fullDuplex mode, Flow
control mechanism will not function.
(2) Flow control mechanism is disabled.
(3) Flow control mechanism is backPressure.
when the port is in fullDuplex mode.This flow control
mechanism will not function.
(4) Flow control mechanism is IEEE 802.3x flow control.
when the port is in halfDuplex mode.This flow control
mechanism will not function.
hundredBaseTX and thousandBaseSX port can be set as:
enabled(1),
disabled(2),
backPressure(3),
dot3xFlowControl(4).
hundredBaseFX port can be set as:
enabled(1),
disabled(2),
backPressure(3).
The actual flow control mechanism is used given by
portFlowCtrlStatus."
DEFVAL { enabled }
::= { portEntry 5 }
portCapabilities OBJECT-TYPE
SYNTAX INTEGER
{
portCap10half(99),
portCap10full(1),
portCap100half(2),
portCap100full(3),
portCap1000half(4),
portCap1000full(5),
reserved6(6),
reserved7(7),
reserved8(8),
reserved9(9),
reserved10(10),
reserved11(11),
reserved12(12),
reserved13(13),
portCapSym(14),
portCapFlowCtrl(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Port capabilities."
::= { portEntry 6 }
portAutonegotiation OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Whether autonegotiation is enabled."
::= { portEntry 7 }
portSpeedDpxStatus OBJECT-TYPE
SYNTAX INTEGER
{
error(1),
halfDuplex10(2),
fullDuplex10(3),
halfDuplex100(4),
fullDuplex100(5),
halfDuplex1000(6),
fullDuplex1000(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The operating speed and duplex mode of the
switched port. If this index is a trunk,
the speed is the speed of its individual members.
If this index is a trunk and the result
is inconsistent among its member ports, this value is
error(1)."
::= { portEntry 8 }
portFlowCtrlStatus OBJECT-TYPE
SYNTAX INTEGER
{
error(1),
backPressure(2),
dot3xFlowControl(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "(2) BackPressure flow control machanism is used.
(3) IEEE 802.3 flow control machanism is used.
(4) Flow control mechanism is disabled.
If this index is a trunk and the result
is inconsistent among its member ports, this value is
error(1)."
::= { portEntry 9 }
-- ****************************************************************************************
-- enterpriseApTftpMgt - File Transfer Mib elements
-- ****************************************************************************************
transferStart OBJECT-TYPE
SYNTAX INTEGER {
go(1),
nogo(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set to go(1) to start a transfer."
::= { enterpriseApFileTransferMgt 1 }
transferType OBJECT-TYPE
SYNTAX INTEGER {
ftp(1),
tftp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of file to transfer."
::= { enterpriseApFileTransferMgt 2 }
fileType OBJECT-TYPE
SYNTAX INTEGER {
opcode(1),
config(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of file to transfer."
::= { enterpriseApFileTransferMgt 3 }
srcFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The source file name for TFTP transfer when a
transfer is next requested via this MIB. This value is set to
the zero length string when no file name has been specified."
::= { enterpriseApFileTransferMgt 4 }
destFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The destination file name for TFTP transfer when a
transfer is next requested via this MIB. This value is set to
the zero length string when no file name has been specified."
::= { enterpriseApFileTransferMgt 5 }
fileServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the TFTP server for transfer
when a download is next requested via this MIB.
This value is set to `0.0.0.0' when no IP address has been
specified."
::= { enterpriseApFileTransferMgt 6 }
userName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The username specified for an FTP Transfer."
::= { enterpriseApFileTransferMgt 7 }
password OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The password specified for an FTP Transfer."
::= { enterpriseApFileTransferMgt 8 }
-- ****************************************************************************************
-- enterpriseApResetMgt - Reset Mib elements
-- ****************************************************************************************
restartOpCodeFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION "Name of op-code file for start-up."
::= { enterpriseApResetMgt 1 }
restartControl OBJECT-TYPE
SYNTAX INTEGER {
running(1),
warmBoot(2),
coldBoot(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and restart the application software. When the device
is running normally, this variable has a value of
running(1)."
::= { enterpriseApResetMgt 2 }
-- ****************************************************************************************
-- enterpriseApIpMgnt - Ip Mib elements
-- ****************************************************************************************
netConfigIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of this Net interface. The default value
for this object is 0.0.0.0. If either the netConfigIPAddress
or netConfigSubnetMask are 0.0.0.0, then when the device
boots, it may use DHCP to try to figure out what these
values should be. If DHCP fails, before the device
can talk on the network, this value must be configured
(e.g., through a terminal attached to the device)."
::= { enterpriseApIpMgt 1 }
netConfigSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The subnet mask of this Net interface. The default value
for this object is 0.0.0.0. If either the netConfigIPAddress
or netConfigSubnetMask are 0.0.0.0, then when the device
boots, it may use DHCP to try to figure out what these
values should be. If DHCP fails, before the device
can talk on the network, this value must be configured
(e.g., through a terminal attached to the device)."
::= { enterpriseApIpMgt 2 }
netDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Address of the default gateway. If this value is
undefined or unknown, it shall have the value 0.0.0.0."
::= { enterpriseApIpMgt 3 }
ipHttpState OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Whether HTTP is enabled."
::= { enterpriseApIpMgt 4 }
ipHttpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port number for HTTP."
::= { enterpriseApIpMgt 5 }
-- ****************************************************************************************
-- enterpriseAPdot11 - 802.11 MIB elements
-- ****************************************************************************************
hpdot11StationConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11StationConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each radio of the AP."
::= { enterpriseAPdot11 1 }
hpdot11StationConfigEntry OBJECT-TYPE
SYNTAX Hpdot11StationConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11portIndex }
::= { hpdot11StationConfigTable 1 }
Hpdot11StationConfigEntry ::= SEQUENCE
{
hpdot11portIndex Integer32,
hpdot11DesiredSSID OCTET STRING,
hpdot11BeaconPeriod INTEGER,
hpdot11DTIMPeriod INTEGER,
hpdot11OperationalRateSet INTEGER,
hpdot11AuthenticationAlgorithm INTEGER
}
hpdot11portIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio index of the AP."
::= { hpdot11StationConfigEntry 1 }
hpdot11DesiredSSID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute reflects the Service Set ID used
in the DesiredSSID parameter of the most recent
MLME_Scan.request. This value may be modified
by an external management entity and used by the
local SME to make decisions about the Scanning process."
::= { hpdot11StationConfigEntry 2 }
hpdot11BeaconPeriod OBJECT-TYPE
SYNTAX INTEGER (20..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall specify the number of ms that a
station shall use for scheduling Beacon transmissions.
This value is transmitted in Beacon and Probe Response
frames."
::= { hpdot11StationConfigEntry 3 }
hpdot11DTIMPeriod OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall specify the number of beacon
intervals that shall elapse between transmission of
Beacons frames containing a TIM element whose DTIM
Count field is 0. This value is transmitted in
the DTIM Period field of Beacon frames."
::= { hpdot11StationConfigEntry 4 }
hpdot11OperationalRateSet OBJECT-TYPE
SYNTAX INTEGER (1..108)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall specify the set of data rates
at which the station may transmit data. Each octet
contains a value representing a rate. Each rate
shall be within the range from 2 to 127,
corresponding to data rates in increments of
500 kb/s from 1 Mbit/s to 63.5 Mbit/s, and shall be
supported (as indicated in the supported rates
table) for receiving data. This value is reported in
transmitted Beacon, Probe Request, Probe Response,
Association Request, Association Response,
Reassociation Request, and Reassociation Response
frames, and is used to determine whether a BSS
with which the station desires to synchronize is
suitable. It is also used when starting a BSS,
as specified in 10.3."
::= { hpdot11StationConfigEntry 5 }
hpdot11AuthenticationAlgorithm OBJECT-TYPE
SYNTAX INTEGER { openSystem (1), sharedKey (2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall be a set of all the authentication
algorithms supported by the STAs. The following are the
default values and the associated algorithm.
Value = 1: Open System
Value = 2: Shared Key"
::= { hpdot11StationConfigEntry 6 }
-- **********************************************************************
-- * End of dot11StationConfig TABLE
-- **********************************************************************
-- **********************************************************************
-- * hpdot11PrivacyEntry TABLE
-- **********************************************************************
hpdot11PrivacyTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11PrivacyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each radio of the AP."
::= { enterpriseAPdot11 2 }
hpdot11PrivacyEntry OBJECT-TYPE
SYNTAX Hpdot11PrivacyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11PrivacyportIndex }
::= { hpdot11PrivacyTable 1 }
Hpdot11PrivacyEntry ::= SEQUENCE
{
hpdot11PrivacyportIndex Integer32,
hpdot11PrivacyInvoked INTEGER,
hpdot11WEPDefaultKeyID INTEGER,
hpdot11WEPKeyMappingLength INTEGER
}
hpdot11PrivacyportIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio index of the AP."
::= { hpdot11PrivacyEntry 1 }
hpdot11PrivacyInvoked OBJECT-TYPE
SYNTAX INTEGER
{
true(1),
false(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this attribute is true, it shall indicate that the IEEE
802.11 WEP mechanism is used for transmitting frames of type
Data. The default value of this attribute shall be false."
::= { hpdot11PrivacyEntry 2 }
hpdot11WEPDefaultKeyID OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall indicate the use of the first,
second, or third element of the WEPDefaultKeys
array when set to values of zero, one, or two(the
fourth are reserved for dynamic key). The
default value of this attribute shall be 0."
REFERENCE "ISO/IEC 8802-11:1999, 8.3.2"
::= { hpdot11PrivacyEntry 3 }
hpdot11WEPKeyMappingLength OBJECT-TYPE
SYNTAX INTEGER (10..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of tuples that dot11WEPKeyMappings can hold."
REFERENCE "ISO/IEC 8802-11:1999, 8.3.2"
::= { hpdot11PrivacyEntry 4 }
-- **********************************************************************
-- * End of dot11Privacy TABLE
-- **********************************************************************
-- MAC Attributes
hpdot11mac OBJECT IDENTIFIER ::= { enterpriseAPdot11 3 }
-- **********************************************************************
-- * dot11OperationTable TABLE
-- **********************************************************************
hpdot11OperationTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11OperationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each radio of the AP."
::= { hpdot11mac 1 }
hpdot11OperationEntry OBJECT-TYPE
SYNTAX Hpdot11OperationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11OperationIndex }
::= { hpdot11OperationTable 1 }
Hpdot11OperationEntry ::= SEQUENCE
{
hpdot11OperationIndex Integer32,
hpdot11RTSThreshold INTEGER,
hpdot11FragmentationThreshold INTEGER
}
hpdot11OperationIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio index of the AP."
::= { hpdot11OperationEntry 1 }
hpdot11RTSThreshold OBJECT-TYPE
SYNTAX INTEGER (0..2347)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall indicate the number of octets in an MPDU,
below which an RTS/CTS handshake shall not be performed. An
RTS/CTS handshake shall be performed at the beginning of any
frame exchange sequence where the MPDU is of type Data or
Management, the MPDU has an individual address in the Address1
field, and the length of the MPDU is greater than
this threshold. (For additional details, refer to Table 21 in
9.7.) Setting this attribute to be larger than the maximum
MSDU size shall have the effect of turning off the RTS/CTS
handshake for frames of Data or Management type transmitted by
this STA. Setting this attribute to zero shall have the effect
of turning on the RTS/CTS handshake for all frames of Data or
Management type transmitted by this STA. The default value of
this attribute shall be 2347."
::= { hpdot11OperationEntry 2 }
hpdot11FragmentationThreshold OBJECT-TYPE
SYNTAX INTEGER (256..2346)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall specify the mandatory maximum size, in
octets, of the MPDU that may be delivered to the PHY. An MSDU
shall be broken into fragments if its size exceeds the value
of this attribute after adding MAC headers and trailers. An
MSDU or MMPDU shall be fragmented when the resulting frame has
an individual address in the Address1 field, and the length of
the frame is larger than this threshold. The default value
for this attribute shall be the lesser of 2346 or the
aMPDUMaxLength of the attached PHY and shall never exceed the
lesser of 2346 or the aMPDUMaxLength of the attached PHY. The
value of this attribute shall never be less than 256."
::= { hpdot11OperationEntry 3 }
-- **********************************************************************
-- * End of dot11OperationTable TABLE
-- **********************************************************************
-- PHY Attributes
hpdot11phy OBJECT IDENTIFIER ::= { enterpriseAPdot11 4 }
-- **********************************************************************
-- * dot11PhyOperationEntry TABLE
-- **********************************************************************
hpdot11PhyOperationTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11PhyOperationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each radio of the AP."
::= { hpdot11phy 1 }
hpdot11PhyOperationEntry OBJECT-TYPE
SYNTAX Hpdot11PhyOperationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11Index }
::= { hpdot11PhyOperationTable 1 }
Hpdot11PhyOperationEntry ::= SEQUENCE
{
hpdot11Index Integer32,
hpdot11CurrentChannel INTEGER,
hpdot11TurboModeEnabled INTEGER,
hpdot11PreambleLength INTEGER
}
hpdot11Index OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio index of the AP."
::= { hpdot11PhyOperationEntry 1 }
hpdot11CurrentChannel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current operating frequency channel of the network"
::= { hpdot11PhyOperationEntry 2 }
hpdot11TurboModeEnabled OBJECT-TYPE
SYNTAX INTEGER
{
none(99),
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute, when true, shall indicate that the
propietory turbo mode option is enabled. The default value of
this attribute shall be false."
::= { hpdot11PhyOperationEntry 3 }
hpdot11PreambleLength OBJECT-TYPE
SYNTAX INTEGER
{
short(1),
long(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute determines whether or not a short or a long
preamble is used to delineate 802.11 frames."
::= { hpdot11PhyOperationEntry 4 }
-- **********************************************************************
-- * End of dot11PhyOperationEntry TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11AuthenticationEntry TABLE
-- **********************************************************************
hpdot11AuthenticationEntry OBJECT IDENTIFIER ::= { enterpriseAPdot11 5 }
hpdot118021xSupport OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute, when true(1), indicates that the Enterprise
Access Point supports the 802.1x authentication algorithm."
::= { hpdot11AuthenticationEntry 1 }
hpdot118021xRequired OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute, when true(1), indicates that the Enterprise
Access Point requires successful 802.1x authentication
for any clients accessing the network."
::= { hpdot11AuthenticationEntry 2 }
-- **********************************************************************
-- * End of dot11Authentication TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11AuthenticationServer TABLE
-- **********************************************************************
hpdot11AuthenticationServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11AuthenticationServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of descriptive and status information about
configuration of each authentication server."
::= { enterpriseAPdot11 6 }
hpdot11AuthenticationServerEntry OBJECT-TYPE
SYNTAX Hpdot11AuthenticationServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11serverIndex }
::= { hpdot11AuthenticationServerTable 1 }
Hpdot11AuthenticationServerEntry ::= SEQUENCE
{
hpdot11serverIndex Integer32,
hpdot11AuthenticationServer IpAddress,
hpdot11AuthenticationPort INTEGER,
hpdot11AuthenticationKey DisplayString,
hpdot11AuthenticationRetransmit INTEGER,
hpdot11AuthenticationTimeout INTEGER
}
hpdot11serverIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio index of the AP."
::= { hpdot11AuthenticationServerEntry 1 }
hpdot11AuthenticationServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the IP address of the
authentication server."
::= { hpdot11AuthenticationServerEntry 2 }
hpdot11AuthenticationPort OBJECT-TYPE
SYNTAX INTEGER (1024..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the UDP Port used by the primary
authentication server."
::= { hpdot11AuthenticationServerEntry 3 }
hpdot11AuthenticationKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the shared key used by the
authentication server."
::= { hpdot11AuthenticationServerEntry 4 }
hpdot11AuthenticationRetransmit OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the retransmit timer length used by the
authentication server."
::= { hpdot11AuthenticationServerEntry 5 }
hpdot11AuthenticationTimeout OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the Timeout value(sec) used by the
authentication server."
::= { hpdot11AuthenticationServerEntry 6 }
-- **********************************************************************
-- * End of dot11AuthenticationServer TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11FilteringTable TABLE
-- **********************************************************************
hpdot11FilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table of status information about
each configured MAC Address Filtering Entry."
::= { enterpriseAPdot11 7 }
hpdot11FilterEntry OBJECT-TYPE
SYNTAX Hpdot11FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the table, containing information
about configuration in one radio of the AP."
INDEX { hpdot11FilterIndex }
::= { hpdot11FilterTable 1 }
Hpdot11FilterEntry ::= SEQUENCE
{
hpdot11FilterIndex Integer32,
hpdot11FilterAddress PhysAddress,
hpdot11FilterStatus INTEGER
}
hpdot11FilterIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Filter index."
::= { hpdot11FilterEntry 1 }
hpdot11FilterAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the MAC address of the
filter entry."
::= { hpdot11FilterEntry 2 }
hpdot11FilterStatus OBJECT-TYPE
SYNTAX INTEGER
{
allowed(30),
denied(31)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This values indicates the Status of the filter entry.
Ifallowed, the client is allowed access to the network.
If disallowed, the no frames will be forwarded to the
network from the client."
::= { hpdot11FilterEntry 3 }
hpdot11smt OBJECT IDENTIFIER ::= { enterpriseAPdot11 8 }
--
-- **********************************************************************
-- * WEP Default Keys Table 11g
-- **********************************************************************
hpdot11WEPDefaultKeys11g OBJECT IDENTIFIER ::= { hpdot11smt 1 }
hpdot11WEPDefaultKeys11gTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hpdot11WEPDefaultKeys11gEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Conceptual table for WEP default keys. This table shall
contain the four WEP default secret key values
corresponding to the four possible KeyID values. The WEP
default secret keys are logically WRITE-ONLY. Attempts to
read the entries in this table shall return unsuccessful
status and values of null or zero. The default value of
each WEP default key shall be null."
REFERENCE
"IEEE Std 802.11-1997, 8.3.2"
::= { hpdot11WEPDefaultKeys11g 1 }
hpdot11WEPDefaultKeys11gEntry OBJECT-TYPE
SYNTAX Hpdot11WEPDefaultKeys11gEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An Entry (conceptual row) in the WEP Default Keys Table.
ifIndex - Each 802.11 interface is represented by an
ifEntry. Interface tables in this MIB module are indexed
by ifIndex."
INDEX { dot11WEPDefaultKey11gLength }
::= { hpdot11WEPDefaultKeys11gTable 1 }
Hpdot11WEPDefaultKeys11gEntry ::=
SEQUENCE {
hpdot11WEPDefaultKey11gLength INTEGER,
hpdot11WEPDefaultKey11gIndex INTEGER,
hpdot11WEPDefaultKey11gValue OCTET STRING
}
hpdot11WEPDefaultKey11gLength OBJECT-TYPE
SYNTAX INTEGER
{
sixtyFour(64),
oneHundredTwentyEight(128),
oneHundredFiftyTwo(152)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 40(64)-bits [5 octets WEP], 104(128)-bits [13 octets] or 128(152)-bits [16 octets]"
DEFVAL { oneHundredTwentyEight }
::= { hpdot11WEPDefaultKeys11gEntry 1 }
hpdot11WEPDefaultKey11gIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The auxiliary variable used to identify instances
of the columnar objects in the WEP Default Keys Table.
The value of this variable is equal to the WEPDefaultKeyID + 1"
::= { hpdot11WEPDefaultKeys11gEntry 2 }
hpdot11WEPDefaultKey11gValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"A 40(64)-bits [5 octets WEP] or 104(128)-bits [13 octets]
default secret key value."
::= { hpdot11WEPDefaultKeys11gEntry 3 }
END