mibs/MIBS/hp/HP-SN-AGENT-MIB

2915 lines
103 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- SECTION 1: Top Level Definitions
HP-SN-AGENT-MIB DEFINITIONS ::= BEGIN
-- BigIron Router Switch Agent MIB Release 2.0.0
-- Revision 10/11/99
-- Copyright 1996 Foundry Networks, Inc.
-- All rights reserved.
-- This Foundry SNMP Management Information Base Specification
-- (Specification) embodies Foundry's confidential and
-- proprietary intellectual property. Foundry retains all
-- title and ownership in the Specification, including any
-- revisions.
-- This Specification is supplied "AS IS," and Foundry makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- Imports
IMPORTS
TimeTicks, IpAddress, Counter, Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
snChassis, snAgentSys, snStack
FROM HP-SN-ROOT-MIB;
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
MacAddress ::=
OCTET STRING (SIZE(6))
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation.
-- For example, an ethernet address would be represented as
-- a string of 6 octets.
-- Groups
snChasGen OBJECT IDENTIFIER ::= { snChassis 1 }
snChasPwr OBJECT IDENTIFIER ::= { snChassis 2 }
snChasFan OBJECT IDENTIFIER ::= { snChassis 3 }
-- SECTION 2: MIB Objects
-- General Chassis Information
snChasType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis type represents the type
of Foundry product being managed. "
::= { snChasGen 1 }
snChasSerNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the chassis. If the
serial number is unknown or unavailable then
the value should be a zero length string."
::= { snChasGen 2 }
-- Power Supply Status
snChasPwrSupplyStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
Chassis Power Supplies. This is a packed bit string;
the 2 power supplies status are encoded into 4 bits
(a nibble).
There are multiple power supplies per chassis in this release.
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
12-31 reserved
11 Power Supply 4 DC (0=bad, 1=good).
10 Power Supply 3 DC (0=bad, 1=good).
9 Power Supply 4 present status (0=present, 1=not-present).
8 Power Supply 3 present status (0=present, 1=not-present).
4-7 reserved
3 Power Supply 2 DC (0=bad, 1=good).
2 Power Supply 1 DC (0=bad, 1=good).
1 Power Supply 2 present status (0=present, 1=not-present).
0 Power Supply 1 present status (0=present, 1=not-present)."
::= { snChasGen 3 }
-- Fan Status
snChasFanStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
fan status. This is a packed bit string. The
status of each fan is encoded into one bit.
bit value meaning
--------- -------
0 fan failure.
1 fan good.
There are two fans per VLAN Switch chassis in this release.
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
4-31 reserved
3 fan4 status
2 fan3 status
1 fan2 status
0 fan1 status"
::= { snChasGen 4 }
snChasMainBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The main board description string. (It is obsoleted for Chassis Product)"
::= { snChasGen 5 }
snChasMainPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ports for the main board. (It is obsoleted for Chassis Product)"
::= { snChasGen 6 }
snChasExpBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The expansion board description string. Expansion
board are those boards attaching on the main board.
(It is obsoleted for Chassis Product)"
::= { snChasGen 7 }
snChasExpPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ports for the expansion board.
(It is obsoleted for Chassis Product)"
::= { snChasGen 8 }
snChasStatusLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel status LEDs. This is a bit-map;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Status LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (Link off)
1 on (Link on)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snChasGen 9 }
snChasTrafficLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel traffic LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no traffic)
1 on (traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snChasGen 10 }
snChasMediaLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Media LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 half duplex
1 full duplex
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snChasGen 11 }
snChasEnablePwrSupplyTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate power supply failure traps."
DEFVAL { enabled }
::= { snChasGen 12 }
snChasMainBrdId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The main board identifier, which can uniquely identify a board
type. It is an encoded octet string with the following meaning:
octet 0 - octet string format version, which identifies the
format of this string.
If format version octet has the value 1, the octets after the
version octet have the following meaning:
octet 1 - product type, FIWG=0x57, FIBB=0x42, FIMLS=0x4D
NI=0x4E, TI=0x54, TIRT=0x52
octet 2 - board type, POWERPC=1, ALPHA=2
The length of the octet string is 27.
If format version octet has the value 2, the octets after the
version octet have the following meaning:
octet 1 - product type:
BI_WG 0x57
BI_BB 0x42
BI_NI 0x4E
octet 2 - module type:
FI_MASTER_FIBER_8G 0x7
FI_MASTER_FIBER_4G 0x5
FI_MASTER_FIBER_2G 0x4
FI_SLAVE_COPPER_24 0xB
MASTER_FIBER_8G 0x0
MASTER_FIBER_4G 0x1
MASTER_FIBER_2G 0x12
MASTER_FIBER_0G 0x14
MASTER_COPPER_16 0x2
MASTER_COPPER_8G 0x6
MASTER_COPPER_12_2 0x9
SLAVE_FIBER_8G 0x8
SLAVE_FIBER_4G 0x3
SLAVE_COPPER_20 0xA
SLAVE_COPPER_24 0xA
SLAVE_100FX_8 0xD
SLAVE_100FX_16 0xC
SLAVE_COPPER_8G 0xE
SLAVE_COPPER_16_2 0xF
STACK_FIBER_8G 0x10
STACK_COPPER_8G 0x11
SLAVE_100FX_24 0x13
The length of the octet string is 28.
Both format version 1 and 2:
octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
PVR_M603EV=7, PVR_M604E=9
octet 4 to
octet 5 - processor speed in MHz
octet 6 - MAC type:
MAC_SEEQ_10_100=1,
MAC_DEC_10_100=2,
MAC_SEEQ_1000=5,
MAC_GMAC_1000=6,
MAC_VLSI_1000=9
octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_ICS=3,
PHY_NATIONAL=4, PHY_LEVEL1=6, PHY_LEVEL16=7,
PHY_LEVEL24=8
octet 8 - port type, COPPER=0, FIBER=1
octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4,
LHB_FIBER=5
octet 10 to
octet 13 - DRAM size in KBytes
octet 14 to
octet 17 - boot flash size in KBytes
octet 18 to
octet 21 - code flash size in KBytes
octet 22 to
octet 27 - serial number.
Format version 1 only:
octet 28 - chassis backplane type.
chassis4000 = 0x00
chassis8000 = 0x04
Turbo8 = 0x07 (stack2)
FastIron2 = 0x06 (stack1)"
::= { snChasGen 13 }
snChasExpBrdId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The expansion board identifier. Expansion board are those
boards attaching on the main board. It is an encoded octet
string with the following meaning:
octet 0 - octet string format version, which identifies
the format of this string.
If format version octet has the value 1, the octets after
the version octet have the following meaning:
octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
GIGA_1PORT=8, GIGA_2PORT=9
octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4
(It is obsoleted for Chassis Product)"
::= { snChasGen 14 }
snChasSpeedLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 10 MBit
1 100 MBit
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snChasGen 15 }
snChasEnableFanTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate fan failure traps."
DEFVAL { enabled }
::= { snChasGen 16 }
snChasIdNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An administratively-assigned chassis identity number,
used by inventory control."
::= { snChasGen 17 }
snChasActualTemperature OBJECT-TYPE
SYNTAX INTEGER (-110..250)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of the chassis. Each unit is 0.5 degrees Celcius.
Only management module built with temperature sensor hardware
is applicable. For those non-applicable management module, it
returns no-such-name."
::= { snChasGen 18 }
snChasWarningTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Actual temperature higher than this threshold value will trigger
the switch to send a temperature warning trap. Each unit is 0.5
degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasGen 19 }
snChasShutdownTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Actual temperature higher than this threshold value will shutdown
a partial of the switch hardware to cool down the system. Each unit
is 0.5 degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasGen 20 }
snChasEnableTempWarnTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate temperature warning traps."
DEFVAL { enabled }
::= { snChasGen 21 }
-- Power Supply Table
snChasPwrSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasPwrSupplyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each power supply information. Only installed
power supply appears in a table row."
::= { snChasPwr 1 }
snChasPwrSupplyEntry OBJECT-TYPE
SYNTAX SnChasPwrSupplyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the power supply table."
INDEX { snChasPwrSupplyIndex }
::= { snChasPwrSupplyTable 1 }
SnChasPwrSupplyEntry ::= SEQUENCE {
snChasPwrSupplyIndex
INTEGER,
snChasPwrSupplyDescription
DisplayString,
snChasPwrSupplyOperStatus
INTEGER
}
snChasPwrSupplyIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to power supply table."
::= { snChasPwrSupplyEntry 1 }
snChasPwrSupplyDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power supply description string."
::= { snChasPwrSupplyEntry 2 }
snChasPwrSupplyOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power supply operation status."
::= { snChasPwrSupplyEntry 3 }
-- Fan Table
snChasFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasFanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each fan information. Only installed
fan appears in a table row."
::= { snChasFan 1 }
snChasFanEntry OBJECT-TYPE
SYNTAX SnChasFanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the fan table."
INDEX { snChasFanIndex }
::= { snChasFanTable 1 }
SnChasFanEntry ::= SEQUENCE {
snChasFanIndex
INTEGER,
snChasFanDescription
DisplayString,
snChasFanOperStatus
INTEGER
}
snChasFanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to fan table."
::= { snChasFanEntry 1 }
snChasFanDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The fan description string."
::= { snChasFanEntry 2 }
snChasFanOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The fan operation status."
::= { snChasFanEntry 3 }
-- Agent Groups
snAgentGbl OBJECT IDENTIFIER ::= { snAgentSys 1 }
snAgentBrd OBJECT IDENTIFIER ::= { snAgentSys 2 }
snAgentTrp OBJECT IDENTIFIER ::= { snAgentSys 3 }
snAgentBoot OBJECT IDENTIFIER ::= { snAgentSys 4 }
snAgCfgEos OBJECT IDENTIFIER ::= { snAgentSys 5 }
snAgentLog OBJECT IDENTIFIER ::= { snAgentSys 6 }
snAgentSysParaConfig OBJECT IDENTIFIER ::= { snAgentSys 7 }
snAgentConfigModule OBJECT IDENTIFIER ::= { snAgentSys 8 }
snAgentUser OBJECT IDENTIFIER ::= { snAgentSys 9 }
snAgentRedundant OBJECT IDENTIFIER ::= { snAgentSys 10 }
-- SECTION 2: MIB Objects
-- Agent's Global Group
snAgReload OBJECT-TYPE
SYNTAX INTEGER {
other(1),
running(2),
reset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to reboot the agent.
The following values can only be read:
other(1).....agent in unknown or other state
running(2)...agent running
The following value can be written:
reset(3).....do a hard reset
The agent will return a
response before the action occurs."
::= { snAgentGbl 1 }
snAgEraseNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
erase(3),
erasing(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to erase NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
erasing(4)...agent is erasing NVRAM flash
The following value can be written:
erase(3).....do erase
The agent will return a response even before the erase is done.
And the read value will be erasing until erase is done.
And the erase request will be rejected until error or normal."
::= { snAgentGbl 2 }
snAgWriteNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
write(3),
writing(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to save all configuration info to
NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
writing(4)...agent is writing NVRAM flash
The following value can be written:
write(3).....do write
The agent will return a response even before the write is done.
And the read value will be writing until write is done.
And the write request will be rejected until error or normal."
::= { snAgentGbl 3 }
snAgConfigFromNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
config(3),
configing(4)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Action object to config the switch from NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
configing(4)...configing from NVRAM flash is in process.
The following value can be written:
config(3).....do config
The agent will return a response after config is done."
::= { snAgentGbl 4 }
-- image and config file down/up load
snAgTftpServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The tftp server address, this will be used for both download/upload
image file and config file."
::= { snAgentGbl 5 }
snAgImgFname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the image file including path currently associated
with the system. When the object is not used, the value is a
zero length string."
::= { snAgentGbl 6 }
snAgImgLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
flashPrepareReadFailure(2),
flashReadError(3),
flashPrepareWriteFailure(4),
flashWriteError(5),
tftpTimeoutError(6),
tftpOutOfBufferSpace(7),
tftpBusy(8),
tftpRemoteOtherErrors(9),
tftpRemoteNoFile(10),
tftpRemoteBadAccess(11),
tftpRemoteDiskFull(12),
tftpRemoteBadOperation(13),
tftpRemoteBadId(14),
tftpRemoteFileExists(15),
tftpRemoteNoUser(16),
operationError(17),
loading(18),
uploadPrimary(19),
downloadPrimary(20),
uploadSecondary(21),
downloadSecondary(22),
tftpWrongFileType(23)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to down/up load a new image
to the agent. The following values:
Error values: from normal(1) to operationError(17) and tftpWrongFileType(23).
loading(18) .. operation is in process.
The following values are used for set :
uploadPrimary(19)..upload the Primary image from flash to tftp server.
downloadPrimary(20)..download the Primary image from tftp server to flash.
uploadSecondary(21)..upload the Secondary image from flash to tftp server.
downloadSecondary(22)..download the Secondary image from tftp server to flash.
The image filename is defined in
snAgImgFname. The tftp server address is defined in snAgTftpServerIp.
Atomic set of snAgImgLoad, snAgImgFname and
snAgTftpServerIp is required to allow down/up load to happen.
And the write request will be rejected during loading until error
or normal."
::= { snAgentGbl 7 }
snAgCfgFname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the config file(s) including path currently associated
with the system. Some agents in special
situations may support a value which contains
multiple file names instead of a single file
name. Multiple names are specified as a list
of file names separated by semicolons (;).
When the object is not used, the value is a
zero length string."
::= { snAgentGbl 8 }
snAgCfgLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
flashPrepareReadFailure(2),
flashReadError(3),
flashPrepareWriteFailure(4),
flashWriteError(5),
tftpTimeoutError(6),
tftpOutOfBufferSpace(7),
tftpBusy(8),
tftpRemoteOtherErrors(9),
tftpRemoteNoFile(10),
tftpRemoteBadAccess(11),
tftpRemoteDiskFull(12),
tftpRemoteBadOperation(13),
tftpRemoteBadId(14),
tftpRemoteFileExists(15),
tftpRemoteNoUser(16),
operationError(17),
loading(18),
uploadFromFlashToServer(20),
downloadToFlashFromServer(21),
uploadFromDramToServer(22),
downloadToDramFromServer(23),
uploadFromFlashToNMS(24),
downloadToFlashFromNMS(25),
uploadFromDramToNMS(26),
downloadToDramFromNMS(27),
operationDoneWithNMS(28),
tftpWrongFileType(29)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to down/up load a config image
to the agent. The following values can be
read :
Error values: from normal(1) to operationError(17) and tftpWrongFileType(29).
loading(18) .. operation is in process.
The following value can be used to set:
uploadFromFlashToServer(20)..upload the config from flash
to tftp server.
downloadToFlashFromServer(21)..download the config to flash
from tftp server.
uploadFromDramToServer(22)..upload the config from DRAM
to tftp server.
downloadToDramFromServer(23)..download the config to DRAM
from tftp server.
The following value can be used to set:
uploadFromFlashToNMS(24)..upload the config from flash to NMS.
downloadToFlashFromNMS(25)..download the config to flash from NMS.
uploadFromDramToNMS(26)..upload the config from DRAM to NMS.
downloadToDramFromNMS(27)..download the config to DRAM from NMS.
The config filename is defined in
snAgCfgFname. The tftp server address is defined in snAgTftpServerIp.
Atomic set of snAgCfgLoad, snAgCfgFname and snAgTftpServerIp is
required to allow down/up load to happen. And the write request
will be rejected during loading until error or normal.
For those NMS commands from (24) to (27), The snAgCfgEosTable MIB must
be sent along in one PDU. A seperate write memory cli or set
snAgWriteNVRAM is required to save the config to NVRAM."
::= { snAgentGbl 9 }
-- default gateway ip address
snAgDefGwayIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default gateway (router) address."
::= { snAgentGbl 10 }
-- image version
snAgImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the running software in the form
'major.minor.maintenance[letters]'."
::= { snAgentGbl 11 }
snAgFlashImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the software image saved in local
storage such as flash memory in the form
'major.minor.maintenance[letters]'. If not
known or not available, then the value is
a zero length string."
::= { snAgentGbl 12 }
snAgGblIfIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interface ip address."
::= { snAgentGbl 13 }
snAgGblIfIpMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interface ip address mask."
::= { snAgentGbl 14 }
snAgGblPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Security Access Password and this is only
allowed to use for setting but not for reading.
An SNMP-Get will get an zero string."
::= { snAgentGbl 15 }
snAgTrpRcvrCurEntry OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current total entries of the Trap
Receiver Table are created."
::= { snAgentGbl 16 }
snAgGblDataRetrieveMode OBJECT-TYPE
SYNTAX INTEGER {
nextbootCfg(0),
operationalData(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"By default, this mode is set to nextbootCfg(0).
The VLAN Table and Port-STP Table data will be retrieved
according to this mode.
nextbootCfg(0).........the nextboot configuration data are retrieved
operationalData(1)..........the current running data are retrieved"
::= { snAgentGbl 19 }
snAgSystemLog OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The system log object to indicate whether any Network
Management Station(NMS) has login. The first byte
of the octet string is the value decribed below and
followed by 4 bytes of secret code.
login(1)..... a value for a NMS to login.
heartbeat(2)... a value for the login NMS periodically to
checkin; Otherwise, the Agent will automatically
set this object to logout(3) after a timeout
period.
logout(3).... a value for a NMS to logout.
changePassword(4).... a value for the login NMS to change
password, only if snAgGblPasswordChangeMode
was configured to 'anyMgmtEntity'.
changeReadOnlyCommunity(5).... a value for the login NMS
to change the read-only community string,
only if snAgGblPasswordChangeMode was
configured to 'anyMgmtEntity'.
changeReadWriteCommunity(6).... a value for the login NMS
to change the read-write community string,
only if snAgGblPasswordChangeMode was
configured to 'anyMgmtEntity'."
::= { snAgentGbl 20 }
snAgGblEnableColdStartTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate cold start traps."
DEFVAL { enabled }
::= { snAgentGbl 21 }
snAgGblEnableLinkUpTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate link up traps."
DEFVAL { enabled }
::= { snAgentGbl 22 }
snAgGblEnableLinkDownTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate link down traps."
DEFVAL { enabled }
::= { snAgentGbl 23 }
snAgGblPasswordChangeMode OBJECT-TYPE
SYNTAX INTEGER {
anyMgmtEntity(1),
consoleAndTelnet(2),
consoleOnly(3),
telnetOnly(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specify which management entity is allowed to change
the password. 'anyMgmtEntity' management entities are
SNMP management station, console command line interface,
and telnet command line interface. For security reason,
this object can only be modified by console command line
interface or telnet command line interface. The default
value is 'consoleAndTelnet', of which both console and
telnet command line interfaces are allowed to change
the password."
::= { snAgentGbl 24 }
snAgGblReadOnlyCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP read community string and this is only allowed
to use for setting but not for reading. An SNMP-Get
will get an zero length string."
::= { snAgentGbl 25 }
snAgGblReadWriteCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP read-write community string and this is only
allowed to use for setting but not for reading. An
SNMP-Get will get an zero length string."
::= { snAgentGbl 26 }
snAgGblCurrentSecurityLevel OBJECT-TYPE
SYNTAX INTEGER (0..5)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This represnts the current log-in security level.
Each level of security requires a password to permit
user for different system configurations."
::= { snAgentGbl 27 }
snAgGblSecurityLevelSet OBJECT-TYPE
SYNTAX INTEGER (0..5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This shows which the security level password to be set."
::= { snAgentGbl 28 }
snAgGblLevelPasswordsMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This shows the bitmap of level passwords which successfully assigned to the system."
::= { snAgentGbl 29 }
snAgGblQueueOverflow OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"false - The device queues are not overflow.
true - The device queues are overflow."
::= { snAgentGbl 30 }
snAgGblBufferShortage OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"false - The device buffers are adequate.
true - The device buffers are in shortage."
::= { snAgentGbl 31 }
snAgGblDmaFailure OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"false - The device DMAs are in good condition.
true - One of the DMAs in the device fails."
::= { snAgentGbl 32 }
snAgGblResourceLowWarning OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"false - No, the device does not have resource-low-warning.
true - Yes, the device does have resource-low-warning."
::= { snAgentGbl 33 }
snAgGblExcessiveErrorWarning OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"false - No, the device does not have any excessive collision, FCS errors, alignment warning etc.
true - Yes, the device does have."
::= { snAgentGbl 34 }
snAgGblCpuUtilData OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistics collection of utilization of the CPU in the device."
::= { snAgentGbl 35 }
snAgGblCpuUtilCollect OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"enable(1) - The beginning of statistics collection of utilization of the CPU in the device.
disable(0) - The end of statistics collection of utilization of the CPU in the device."
::= { snAgentGbl 36 }
snAgGblTelnetTimeout OBJECT-TYPE
SYNTAX INTEGER (0..240)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Telnet session idling timeout value. Writing value 0 to
this object never timeouts any telnet sessions. Each value
unit is one minute."
::= { snAgentGbl 37 }
snAgGblEnableWebMgmt OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable web management."
DEFVAL { enabled }
::= { snAgentGbl 38 }
snAgGblSecurityLevelBinding OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This represnts the binding of a given password to which
security level. A value of 255 indicates an invalid
binding."
::= { snAgentGbl 39 }
snAgGblEnableSLB OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable/disable Server Load Balancing."
::= { snAgentGbl 40 }
snAgSoftwareFeature OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit string representing the software feature of the running
switch/router image. These features were conditional compiled
to different product images. For each bit, exist feature has
a value of 1, but non-exist feature has a value of 0.
octet 0, bit 0 - RMON
octet 0, bit 1 - ipx switching
octet 0, bit 2 - server load balancing
octet 0, bit 3 - layer 3 filter in switch
octet 0, bit 4 - ipx routing
octet 0, bit 5 - appletalk routing
octet 0, bit 6 - ip multicast routing
octet 0, bit 7 - local access control
octet 1, bit 0 - BGP routing
octet 1, bit 1 - loopback interface
octet 1, bit 2 - BigIron multi-management module
octet 1, bit 3 - BigIron SYSIF II
octet 1, bit 4 - BigIron POS support
octet 1, bit 5 - appletalk cable vlan
octet 1, bit 6 - 64 subnet
octet 1, bit 7 - multi-slot trunk
octet 2, bit 0 - TACACS
octet 2, bit 1 - Gigabit Ethernet port auto-negotiation mode
octet 2, bit 2 - FSRP
octet 2, bit 3 - Exodus requested OSPF enhancement
octet 2, bit 4 - OSPF NSSA
octet 2, bit 5 - POS
octet 2, bit 6 - QOS
octet 2, bit 7 - Single Span
octet 3, bit 0 - Fast Span
octet 3, bit 1 - Base L3
octet 3, bit 2 - static log buffer
Bit 0 is the least significant bit of an octet, and
bit 7 is the most significant bit of an octet."
::= { snAgentGbl 41 }
snAgGblEnableModuleInsertedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate hardware module inserted to chassis traps."
DEFVAL { enabled }
::= { snAgentGbl 42 }
snAgGblEnableModuleRemovedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate hardware module removed from chassis traps."
DEFVAL { enabled }
::= { snAgentGbl 43 }
snAgGblTrapMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A generic trap message string."
::= { snAgentGbl 44 }
snAgGblEnableTelnetServer OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable telnet server in device."
DEFVAL { enabled }
::= { snAgentGbl 45 }
snAgGblTelnetPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Telnet Access Password and this is only
allowed to use for setting but not for reading.
An SNMP-Get will get an zero string."
::= { snAgentGbl 46 }
snAgBuildDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date of the built software."
::= { snAgentGbl 47 }
snAgBuildtime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time of the built software."
::= { snAgentGbl 48 }
snAgBuildVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the built software in the form
'major.minor.maintenance[letters]'."
::= { snAgentGbl 49 }
-- Agent Board Table
snAgentBrdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each physical board information."
::= { snAgentBrd 1 }
snAgentBrdEntry OBJECT-TYPE
SYNTAX SnAgentBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the Agent Board table."
INDEX { snAgentBrdIndex }
::= { snAgentBrdTable 1 }
SnAgentBrdEntry ::= SEQUENCE {
snAgentBrdIndex
INTEGER,
snAgentBrdMainBrdDescription
DisplayString,
snAgentBrdMainBrdId
OCTET STRING,
snAgentBrdMainPortTotal
INTEGER,
snAgentBrdExpBrdDescription
DisplayString,
snAgentBrdExpBrdId
OCTET STRING,
snAgentBrdExpPortTotal
INTEGER,
snAgentBrdStatusLeds
INTEGER,
snAgentBrdTrafficLeds
INTEGER,
snAgentBrdMediaLeds
INTEGER,
snAgentBrdSpeedLeds
INTEGER,
snAgentBrdModuleStatus
INTEGER,
snAgentBrdRedundantStatus
INTEGER,
snAgentBrdAlarmLeds
INTEGER,
snAgentBrdTxTrafficLeds
INTEGER,
snAgentBrdRxTrafficLeds
INTEGER
}
snAgentBrdIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Agent Interface Table."
::= { snAgentBrdEntry 1 }
snAgentBrdMainBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The main board description string."
::= { snAgentBrdEntry 2 }
snAgentBrdMainBrdId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The main board identifier, which can uniquely identify a board
type. It is an encoded octet string with the following meaning:
octet 0 - octet string format version, which identifies the
format of this string.
If format version octet has the value 2, the octets after the
version octet have the following meaning:
octet 1 - product type:
BI_WG 0x57
BI_BB 0x42
BI_NI 0x4E
octet 2 - module type:
MASTER_FIBER_8G 0x0
MASTER_FIBER_4G 0x1
MASTER_FIBER_2G 0x12
MASTER_FIBER_0G 0x14
MASTER_COPPER_16 0x2
MASTER_COPPER_8G 0x6
MASTER_COPPER_12_2 0x9
SLAVE_FIBER_8G 0x8
SLAVE_FIBER_4G 0x3
SLAVE_FIBER_2G 0x17
SLAVE_COPPER_8G 0xE
SLAVE_COPPER_2G 0x18
SLAVE_COPPER_16_2 0xF
SLAVE_COPPER_20 0xA
SLAVE_COPPER_24 0xA
SLAVE_100FX_8 0xD
SLAVE_100FX_16 0xC
SLAVE_100FX_24 0x13
STACK_FIBER_8G 0x10
STACK_COPPER_8G 0x11
POS_622M 0x15
POS_155M 0x16
octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
PVR_M603EV=7, PVR_M604E=9
octet 4 to
octet 5 - processor speed in MHz
octet 6 - MAC type:
MAC_SEEQ_10_100=1,
MAC_DEC_10_100=2,
MAC_SEEQ_1000=5,
MAC_GMAC_1000=6,
MAC_VLSI_1000=9
octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_ICS=3,
PHY_NATIONAL=4, PHY_LEVEL1=6, PHY_LEVEL16=7,
PHY_LEVEL24=8
octet 8 - port type, COPPER=0, FIBER=1
octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3
octet 10 to
octet 13 - DRAM size in KBytes
octet 14 to
octet 17 - boot flash size in KBytes
octet 18 to
octet 21 - code flash size in KBytes
octet 22 to
octet 27 - serial number.
octet 28 - chassis backplane type.
chassis4000 = 0x00
chassis8000 = 0x04
Turbo8 = 0x07 (stack2)
FastIron2 = 0x06 (stack1)"
::= { snAgentBrdEntry 3 }
snAgentBrdMainPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ports for the main board."
::= { snAgentBrdEntry 4 }
snAgentBrdExpBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The expansion board description string. Expansion
board are those boards attaching on the main board."
::= { snAgentBrdEntry 5 }
snAgentBrdExpBrdId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The expansion board identifier. Expansion board are those
boards attaching on the main board. It is an encoded octet
string with the following meaning:
octet 0 - octet string format version, which identifies
the format of this string.
If format version octet has the value 1, the octets after
the version octet have the following meaning:
octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
GIGA_1PORT=8, GIGA_2PORT=9
octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4"
::= { snAgentBrdEntry 6 }
snAgentBrdExpPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ports for the expansion board."
::= { snAgentBrdEntry 7 }
snAgentBrdStatusLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel status LEDs. This is a bit-map;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 32 that means 32 Ports Status LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (Link off)
1 on (Link on)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 8 }
snAgentBrdTrafficLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel traffic LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no traffic)
1 on (traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 9 }
snAgentBrdMediaLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Media LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 half duplex
1 full duplex
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 10 }
snAgentBrdSpeedLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 10 MBit
1 100 MBit
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 11 }
snAgentBrdModuleStatus OBJECT-TYPE
SYNTAX INTEGER {
moduleEmpty(0),
moduleGoingDown(2),
moduleRejected(3),
moduleBad(4),
moduleComingUp(9),
moduleRunning(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"By default, this mode is set to notActivated(0).
moduleEmpty(0) ......... The slot of the chassis is empty.
moduleGoingDown(2) ..... The module is going down.
moduleRejected(3) ...... The module is being rejected due to wrong configuration.
moduleBad(4) ........... The module Hardware is bad.
moduleComingUp(9) ...... The module is in power-up cycle.
moduleRunning(10) ....... The module is running."
::= { snAgentBrdEntry 12 }
snAgentBrdRedundantStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
active(2),
standby(3),
crashed(4),
comingUp(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The redundant status of a module. Non-management module always
returns other(1). Management module returns the rest of the
states."
::= { snAgentBrdEntry 13 }
snAgentBrdAlarmLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 no alarm
1 alarm
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 14 }
snAgentBrdTxTrafficLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel transmit traffic LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Transmit Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no transmit traffic)
1 on (transmit traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 15 }
snAgentBrdRxTrafficLeds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit array that contains the value of the
front panel receive traffic LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Receive Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no receive traffic)
1 on (receive traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 16 }
-- Trap Receiver Table
snAgTrpRcvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgTrpRcvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of managers which to send traps."
::= { snAgentTrp 1 }
snAgTrpRcvrEntry OBJECT-TYPE
SYNTAX SnAgTrpRcvrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the trap receiver table.
The column snAgTrpRcvrStatus is used to create
and delete rows in the table. Creation requires
a SET PDU with objects snAgTrpRcvrIndex,
snAgTrpRcvrIpAddr, snAgTrpRcvrComm and
snAgTrpRcvrStatus."
INDEX { snAgTrpRcvrIndex }
::= { snAgTrpRcvrTable 1 }
SnAgTrpRcvrEntry ::= SEQUENCE {
snAgTrpRcvrIndex
INTEGER,
snAgTrpRcvrIpAddr
IpAddress,
snAgTrpRcvrComm
OCTET STRING,
snAgTrpRcvrStatus
INTEGER
}
snAgTrpRcvrIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Trap Receiver Table."
::= { snAgTrpRcvrEntry 1 }
snAgTrpRcvrIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ip address for
SNMP manager that is to receive the trap."
::= { snAgTrpRcvrEntry 2 }
snAgTrpRcvrComm OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string to use."
::= { snAgTrpRcvrEntry 3 }
snAgTrpRcvrStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
ignore(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete rows in the table and control
if they are used. The values
that can be written are:
ignore(5)...don't use this entry to
send traps to at this time
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(5) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
other(1)....some other case
valid(2)....the row exists and is valid
ignore(5)...don't use this entry to
send traps to at this time"
::= { snAgTrpRcvrEntry 4 }
-- Boot Sequence Table
snAgBootSeqTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgBootSeqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of image load sequnce instructions to the boot code.
Boot code will start from instruction of the first valid entry
to load the image. If failed, it will use the second valid
entry and so on, until a succesful load has completed. Each
entry must have an unique instruction, duplicate instructions
will be rejected."
::= { snAgentBoot 1 }
snAgBootSeqEntry OBJECT-TYPE
SYNTAX SnAgBootSeqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the boot sequence table."
INDEX { snAgBootSeqIndex }
::= { snAgBootSeqTable 1 }
SnAgBootSeqEntry ::= SEQUENCE {
snAgBootSeqIndex
INTEGER,
snAgBootSeqInstruction
INTEGER,
snAgBootSeqIpAddr
IpAddress,
snAgBootSeqFilename
DisplayString,
snAgBootSeqRowStatus
INTEGER
}
snAgBootSeqIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the boot sequence table."
::= { snAgBootSeqEntry 1 }
snAgBootSeqInstruction OBJECT-TYPE
SYNTAX INTEGER {
fromPrimaryFlash(1),
fromSecondaryFlash(2),
fromTftpServer(3),
fromBootpServer(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The instruction for the boot code."
::= { snAgBootSeqEntry 2 }
snAgBootSeqIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ip address of the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgBootSeqEntry 3 }
snAgBootSeqFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The image filename on the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgBootSeqEntry 4 }
snAgBootSeqRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a boot sequence table entry."
::= { snAgBootSeqEntry 5 }
--- Encoded Octet Strings for the Configuration File Transfer
snAgCfgEosTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgCfgEosEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the fragmented Configuration File data packet
with checksum include in each rows of this table. A SNMP-SET
represents configuration file download, and a SNMP-GET represents
configuration file upload. This action is only if the SNMP-SET of
snAgCfgLoad command is sent along with this table consecutively. The
applicable snAgCfgLoad command value is as followings:
uploadFromFlashToNMS(23),
downloadToFlashFromNMS(24),
uploadFromDramToNMS(25),
downloadToDramFromNMS(26)."
::= { snAgCfgEos 1 }
snAgCfgEosEntry OBJECT-TYPE
SYNTAX SnAgCfgEosEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An EOS row in the table of encoded octet strings for table
snAgCfgEosTable. "
INDEX { snAgCfgEosIndex }
::= { snAgCfgEosTable 1 }
SnAgCfgEosEntry ::=
SEQUENCE {
snAgCfgEosIndex
INTEGER,
snAgCfgEosPacket
OCTET STRING,
snAgCfgEosChkSum
INTEGER
}
snAgCfgEosIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each VLAN EOS Buffer Identifier have a multiple
VLAN table entries."
::= { snAgCfgEosEntry 1 }
snAgCfgEosPacket OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1000))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An encoded octet string. On reads it contains an integral
number of configuration file data packets. The size
of each encoded octet string is less than or equal to 1400
bytes."
::= { snAgCfgEosEntry 2 }
snAgCfgEosChkSum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A checksum of each configuration file data packet."
::= { snAgCfgEosEntry 3 }
-- Stackable Management Group
snStackGen OBJECT IDENTIFIER ::= { snStack 1 }
snStackSecSwitchInfo OBJECT IDENTIFIER ::= { snStack 2 }
-- MIB Objects
-- General Stackable Management Information
snStackPriSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Stackable Management Primary Switch mode
either enabled or disabled and the default is
disabled mode.
enabled(1)...........primary switch enabled
disabled(0)..........primary switch disabled"
::= { snStackGen 1 }
snStackMaxSecSwitch OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Maximum Secondary Switches are allowed in the
Stackable Management Group."
::= { snStackGen 2 }
snStackTotalSecSwitch OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Total Secondary Switches currently connected to the
Stackable Management Group."
::= { snStackGen 3 }
snStackSyncAllSecSwitch OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
device(2),
global(3),
local(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Synchronize all the secondary switches in the
Stackable Management Group with the following commands.
device(2)...........device related parameters.
global(3)...........global parameters.
local(4)............local parameters.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)...........invalid result."
::= { snStackGen 4 }
snStackSmSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Slot 0 is the Master slot and Slot 1-8 are slaves.
All the slot-based MIB data can be retrieved with respect to
this slot index such as snChassis global MIB. "
::= { snStackGen 5 }
snStackFmpSetProcess OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
pending(1),
failure(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"normal(0) - The set process is either in an idle state or FMP-SET-SUCCESS state.
pending(1) - The pending process is waiting for the result of an FMP-SET.
failure(2) - The failure result of an FMP-SET."
::= { snStackGen 6 }
-- Stackable Management Secondary Switch Information Table
snStackSecSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackSecSwitchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If snSwGroupOperMode is configured as basic mode
which is VLAN by Port, Layer2 switching,
then this table is valid. Each VLAN switch port
could have a number of VLAN IDs."
::= { snStackSecSwitchInfo 1 }
snStackSecSwitchEntry OBJECT-TYPE
SYNTAX SnStackSecSwitchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Stackable Management Secondary Switch
Information table."
INDEX {
snStackSecSwitchIndex
}
::= { snStackSecSwitchTable 1 }
SnStackSecSwitchEntry ::= SEQUENCE {
snStackSecSwitchIndex
INTEGER,
snStackSecSwitchSlotId
INTEGER,
snStackSecSwitchPortCnts
INTEGER,
snStackSecSwitchEnabled
INTEGER,
snStackSecSwitchAck
INTEGER,
snStackSecSwitchMacAddr
MacAddress,
snStackSecSwitchSyncCmd
INTEGER,
snStackSecSwitchIpAddr
IpAddress,
snStackSecSwitchSubnetMask
IpAddress,
snStackSecSwitchCfgCmd
INTEGER
}
snStackSecSwitchIndex OBJECT-TYPE
SYNTAX INTEGER (1..26)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The secondary switch index must not be greater than the snStackMaxSecSwitch."
::= { snStackSecSwitchEntry 1 }
snStackSecSwitchSlotId OBJECT-TYPE
SYNTAX INTEGER (1..26)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The secondary switch slot ID must be set before the Configuration
command sent from the primary switch to the secondary switch
either manually or automatically - snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 2 }
snStackSecSwitchPortCnts OBJECT-TYPE
SYNTAX INTEGER (1..26)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports in this secondary switch."
::= { snStackSecSwitchEntry 3 }
snStackSecSwitchEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The secondary switch has been selected to Stackable Management Group."
::= { snStackSecSwitchEntry 4 }
snStackSecSwitchAck OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The secondary switch has sent reponse to the primary switch."
::= { snStackSecSwitchEntry 5 }
snStackSecSwitchMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The secondary switch physical address. The physical address
represents a MAC Station."
::= { snStackSecSwitchEntry 6 }
snStackSecSwitchSyncCmd OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
device(2),
global(3),
local(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Synchronize the secondary switches in the
Stackable Management Group with the following commands.
device(2)...........device related parameters.
global(3)...........global parameters.
local(4)............local parameters.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)...........invalid result."
::= { snStackSecSwitchEntry 7 }
snStackSecSwitchIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The secondary switch IP Address and is used for
manual-command of snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 8 }
snStackSecSwitchSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The secondary switch IP Subnet Mask and is used for
manual-command of snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 9 }
snStackSecSwitchCfgCmd OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
auto(2),
manual(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"snStackSecSwitchSlotId must be set before the Configuration
command sent from the primary switch to the secondary switch
either manually or automatically.
auto(2)...........auto-configuration command sent.
manual(3).........manual-configuration command sent.
if manual-mode is used, snStackSecSwitchIpAddr
and snStackSecSwitchSubnetMask must be
first set before this command is sent.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)..........invalid result."
::= { snStackSecSwitchEntry 10 }
-- System Logging Group
snAgSysLogGbl OBJECT IDENTIFIER ::= { snAgentLog 1 }
snAgSysLogGblEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable system logging."
DEFVAL { enabled }
::= { snAgSysLogGbl 1 }
snAgSysLogGblBufferSize OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of dynamic system logging entries."
DEFVAL { 50 }
::= { snAgSysLogGbl 2 }
snAgSysLogGblClear OBJECT-TYPE
SYNTAX INTEGER { normal(0), clearAll(1), clearDynamic(2), clearStatic(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear dynamic and/or static system logging buffers."
::= { snAgSysLogGbl 3 }
snAgSysLogGblCriticalLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filter events going to the logging buffer. This is a packed
bit string object of which each bit has the following meaning:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
8-31 reserved
7 Warning (warning conditions)
6 Notification (normal but significant conditions)
5 Informational (informational messages)
4 Error (error conditions)
3 Emergency (system is unusable)
2 Debugging (debugging messages)
1 Critical (critical conditions)
0 Alert (immediate action needed)
Setting a critical level bit to 1 makes the logging buffer
accept the corresponding event. Resetting a critical level
bit to 0 makes the logging buffer reject the corresponding
event."
DEFVAL { 255 }
::= { snAgSysLogGbl 4 }
snAgSysLogGblLoggedCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number events logged in the system logging buffer."
::= { snAgSysLogGbl 5 }
snAgSysLogGblDroppedCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of events dropped."
::= { snAgSysLogGbl 6 }
snAgSysLogGblFlushedCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times that the system logging buffer was cleared."
::= { snAgSysLogGbl 7 }
snAgSysLogGblOverrunCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times that the system logging buffer was wrapped
around."
::= { snAgSysLogGbl 8 }
snAgSysLogGblServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of syslog server."
::= { snAgSysLogGbl 9 }
snAgSysLogGblFacility OBJECT-TYPE
SYNTAX INTEGER {
kern(1),
user(2),
mail(3),
daemon(4),
auth(5),
syslog(6),
lpr(7),
news(8),
uucp(9),
sys9(10),
sys10(11),
sys11(12),
sys12(13),
sys13(14),
sys14(15),
cron(16),
local0(17),
local1(18),
local2(19),
local3(20),
local4(21),
local5(22),
local6(23),
local7(24)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Facility code."
DEFVAL { user }
::= { snAgSysLogGbl 10 }
-- Dynamic System Logging Buffer Table
snAgSysLogBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgSysLogBufferEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Dynamic system logging buffer table."
::= { snAgentLog 2 }
snAgSysLogBufferEntry OBJECT-TYPE
SYNTAX SnAgSysLogBufferEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the dynamic system logging buffer table."
INDEX { snAgSysLogBufferIndex }
::= { snAgSysLogBufferTable 1 }
SnAgSysLogBufferEntry ::= SEQUENCE {
snAgSysLogBufferIndex
INTEGER,
snAgSysLogBufferTimeStamp
TimeTicks,
snAgSysLogBufferCriticalLevel
INTEGER,
snAgSysLogBufferMessage
DisplayString,
snAgSysLogBufferCalTimeStamp
DisplayString
}
snAgSysLogBufferIndex OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the dynamic system logging buffer table."
::= { snAgSysLogBufferEntry 1 }
snAgSysLogBufferTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A time stamp when the event is logged."
::= { snAgSysLogBufferEntry 2 }
snAgSysLogBufferCriticalLevel OBJECT-TYPE
SYNTAX INTEGER {
other(1),
alert(2),
critical(3),
debugging(4),
emergency(5),
error(6),
informational(7),
notification(8),
warning(9) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The critical level of this event."
::= { snAgSysLogBufferEntry 3 }
snAgSysLogBufferMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The system logging message."
::= { snAgSysLogBufferEntry 4 }
snAgSysLogBufferCalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A time stamp when the event is logged. This object returns
a NULL terminated time stamp string if the system calendar
time was set. It returns a zero length string if the system
calendar time was not set."
::= { snAgSysLogBufferEntry 5 }
-- Static System Logging Buffer Table
snAgStaticSysLogBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgStaticSysLogBufferEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Static system logging buffer table."
::= { snAgentLog 3 }
snAgStaticSysLogBufferEntry OBJECT-TYPE
SYNTAX SnAgStaticSysLogBufferEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the static system logging buffer table."
INDEX { snAgStaticSysLogBufferIndex }
::= { snAgStaticSysLogBufferTable 1 }
SnAgStaticSysLogBufferEntry ::= SEQUENCE {
snAgStaticSysLogBufferIndex
INTEGER,
snAgStaticSysLogBufferTimeStamp
TimeTicks,
snAgStaticSysLogBufferCriticalLevel
INTEGER,
snAgStaticSysLogBufferMessage
DisplayString,
snAgStaticSysLogBufferCalTimeStamp
DisplayString
}
snAgStaticSysLogBufferIndex OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the static system logging buffer table."
::= { snAgStaticSysLogBufferEntry 1 }
snAgStaticSysLogBufferTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A time stamp when the event is logged."
::= { snAgStaticSysLogBufferEntry 2 }
snAgStaticSysLogBufferCriticalLevel OBJECT-TYPE
SYNTAX INTEGER {
other(1),
alert(2),
critical(3),
debugging(4),
emergency(5),
error(6),
informational(7),
notification(8),
warning(9) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The critical level of this event."
::= { snAgStaticSysLogBufferEntry 3 }
snAgStaticSysLogBufferMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The system logging message."
::= { snAgStaticSysLogBufferEntry 4 }
snAgStaticSysLogBufferCalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A time stamp when the event is logged. This object returns
a NULL terminated time stamp string if the system calendar
time was set. It returns a zero length string if the system
calendar time was not set."
::= { snAgStaticSysLogBufferEntry 5 }
-- Agent System Parameters Configuration Table
snAgentSysParaConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentSysParaConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Agent of each board."
::= { snAgentSysParaConfig 1 }
snAgentSysParaConfigEntry OBJECT-TYPE
SYNTAX SnAgentSysParaConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the Agent System Parameters Configuation table."
INDEX { snAgentSysParaConfigIndex }
::= { snAgentSysParaConfigTable 1 }
SnAgentSysParaConfigEntry ::= SEQUENCE {
snAgentSysParaConfigIndex
INTEGER,
snAgentSysParaConfigDescription
DisplayString,
snAgentSysParaConfigMin
INTEGER,
snAgentSysParaConfigMax
INTEGER,
snAgentSysParaConfigDefault
INTEGER,
snAgentSysParaConfigCurrent
INTEGER
}
snAgentSysParaConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Agent System Parameters Configuation Table."
::= { snAgentSysParaConfigEntry 1 }
snAgentSysParaConfigDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The main board description string."
::= { snAgentSysParaConfigEntry 2 }
snAgentSysParaConfigMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 3 }
snAgentSysParaConfigMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 4 }
snAgentSysParaConfigDefault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 5 }
snAgentSysParaConfigCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current configurated value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 6 }
-- Agent Configured Module Table
snAgentConfigModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentConfigModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each configured module information."
::= { snAgentConfigModule 1 }
snAgentConfigModuleEntry OBJECT-TYPE
SYNTAX SnAgentConfigModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the Agent Configured Module table."
INDEX { snAgentConfigModuleIndex }
::= { snAgentConfigModuleTable 1 }
SnAgentConfigModuleEntry ::= SEQUENCE {
snAgentConfigModuleIndex
INTEGER,
snAgentConfigModuleType
INTEGER,
snAgentConfigModuleRowStatus
INTEGER
}
snAgentConfigModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Agent Configured Module Table."
::= { snAgentConfigModuleEntry 1 }
snAgentConfigModuleType OBJECT-TYPE
SYNTAX INTEGER {
bi8PortGigManagementModule(0),
bi4PortGigManagementModule(1),
bi16PortCopperManagementModule(2),
bi4PortGigModule(3),
fi2PortGigManagementModule(4),
fi4PortGigManagementModule(5),
bi8PortGigCopperManagementModule(6),
fi8PortGigManagementModule(7),
bi8PortGigModule(8),
bi24PortCopperModule(10),
fi24PortCopperModule(11),
bi16Port100FXModule(12),
bi8Port100FXModule(13),
bi8PortGigCopperModule(14),
bi2PortGigManagementModule(18),
bi24Port100FXModule(19),
bi0PortManagementModule(20),
pos622MbsModule(21),
pos155MbsModule(22),
bi2PortGigModule(23),
bi2PortGigCopperModule(24),
fi2PortGigModule(25),
fi4PortGigModule(26),
fi8PortGigModule(27),
fi8PortGigCopperModule(28),
fi8PortGigCopperManagementModule(29),
pos155Mbs2PModule(30),
fi2PortGigCopperManagementModule(31),
fi4PortGigCopperManagementModule(32),
bi4PortGigCopperManagementModule(33),
bi2PortGigCopperManagementModule(34)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Configured Module Type."
::= { snAgentConfigModuleEntry 2 }
snAgentConfigModuleRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a configured module table entry."
::= { snAgentConfigModuleEntry 3 }
-- Agent User Access Group
snAgentUserGbl OBJECT IDENTIFIER ::= { snAgentUser 1 }
snAgentUserMaxAccnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum number of user account entries can be configured."
::= { snAgentUserGbl 1 }
-- Agent User Account Table
snAgentUserAccntTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentUserAccntEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of user account information."
::= { snAgentUser 2 }
snAgentUserAccntEntry OBJECT-TYPE
SYNTAX SnAgentUserAccntEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the Agent User table."
INDEX { snAgentUserAccntName }
::= { snAgentUserAccntTable 1 }
SnAgentUserAccntEntry ::= SEQUENCE {
snAgentUserAccntName
DisplayString,
snAgentUserAccntPassword
DisplayString,
snAgentUserAccntEncryptCode
INTEGER,
snAgentUserAccntPrivilege
INTEGER,
snAgentUserAccntRowStatus
INTEGER
}
snAgentUserAccntName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user name."
::= { snAgentUserAccntEntry 1 }
snAgentUserAccntPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user password."
::= { snAgentUserAccntEntry 2 }
snAgentUserAccntEncryptCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The password encryption method code."
::= { snAgentUserAccntEntry 3 }
snAgentUserAccntPrivilege OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user privilege."
::= { snAgentUserAccntEntry 4 }
snAgentUserAccntRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a user account table entry."
::= { snAgentUserAccntEntry 5 }
-- Agent Redundant Group
snAgentRedunGbl OBJECT IDENTIFIER ::= { snAgentRedundant 1 }
snAgentRedunActiveMgmtMod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Slot number of the active management module. Setting
this object does not take effect immediately. Saving
configuration data to flash storage and reboot the
system are required to take effect. Setting a value of 0
requests the system to auto-select an active management
module after power up."
DEFVAL { 0 }
::= { snAgentRedunGbl 1 }
snAgentRedunSyncConfig OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frequency of the backup management module copying the
configuration data from the active management module.
Each unit is 1 second. Setting a value 0 will disable
the synchronization copy. Setting a negative value will
initiate the synchronization copy once immediately."
DEFVAL { 10 }
::= { snAgentRedunGbl 2 }
snAgentRedunBkupCopyBootCode OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If enabled(1), the backup management module copies the boot code
from the active management module to its boot code flash storage
after power up, and whenever the active management module's boot
code is updated. The backup management module does not copy if
both boot codes were identical."
DEFVAL { disabled }
::= { snAgentRedunGbl 3 }
snAgentEnableMgmtModRedunStateChangeTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate management module redundancy state change traps."
DEFVAL { enabled }
::= { snAgentRedunGbl 4 }
snAgentRedunBkupBootLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
operationError(17),
downloadBackup(20)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action object to down load a new boot code from boot flash storage
of the active management module to the backup management module.
The following are returned values from get operation:
normal(1)............no operation
operationError(17)...error codes
The following are input values from set operation:
downloadBackup(20)...download the boot code from the active
management module to the backup management
module
Any set operation is rejected during loading until error
or normal state is reached."
::= { snAgentRedunGbl 5 }
snAgentRedunSwitchOver OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To force a switch-over from standby to active state
if the backup management module exists in a chassis."
::= { snAgentRedunGbl 6 }
END