-- Copyright (C) 2004 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description: This mib file is used for management of huawei Class Based
-- FR QoS information.
-- Reference:
-- Version: V1.0
-- History:
-- 2004-07-12 V1.00 CAOLEI publish
-- =================================================================
HUAWEI-FR-QOS-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
ifIndex
FROM RFC1213-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
IpAddress, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, DisplayString, MacAddress
FROM SNMPv2-TC;
--
-- type definitions in the policy
--
-- Direction
DirectionType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Direction Policy apply on."
SYNTAX INTEGER {
inbound (1),
outbound (2)
}
--
-- end of type definitions in policy
--
-- 1.3.6.1.4.1.2011.5.25.32
hwQoS OBJECT IDENTIFIER ::= { hwDatacomm 32 }
-- 1.3.6.1.4.1.2011.5.25.36
hwFrQoSMib MODULE-IDENTITY
LAST-UPDATED "200407120000Z" -- JULY 12, 2004 at 00:00 GMT
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
" R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:support@huawei.com "
DESCRIPTION
"The HUAWEI-FR-QOS-MIB contains objects to
Manage configuration and Monitor running state
for Class Based FR QoS feature.
*********************************
MIB Tables
**********************************
This MIB consists of the following tables:
1 : hwFrClassCfgInfoTable
2 : hwCirAllowCfgInfoTable
3 : hwCirCfgInfoTable
4 : hwIfApplyFrClassTable
5 : hwPvcApplyFrClassTable
6 : hwFrPvcBandwidthTable
7 : hwRTPFrClassApplyTable
8 : hwRTPFrPvcQueueRunInfoTable
"
::= { hwQoS 3 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.2011.5.25.36.1
hwFrQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSMib 1 }
-- hwFrClassObjects
hwFrClassObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 1 }
-- Fr Class Next Index
hwFrClassIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to be used for
hwFrClassIndex when creating rows in the
hwFrClassCfgInfoTable. Begin with 0.
"
::= { hwFrClassObjects 1 }
-- Fr Class
hwFrClassCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwFrClassCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Fr Class configuration information."
::= { hwFrClassObjects 2 }
hwFrClassCfgInfoEntry OBJECT-TYPE
SYNTAX HwFrClassCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Class Configuration Information Entry."
INDEX { hwFrClassIndex }
::= { hwFrClassCfgInfoTable 1 }
HwFrClassCfgInfoEntry ::=
SEQUENCE {
hwFrClassIndex
Integer32,
hwFrClassName
OCTET STRING,
hwFrClassRowStatus
RowStatus
}
hwFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0."
::= { hwFrClassCfgInfoEntry 1 }
hwFrClassName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of Fr Class."
::= { hwFrClassCfgInfoEntry 2 }
hwFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwFrClassCfgInfoEntry 3 }
-- Cir Allow on the Fr Class
hwCirAllowCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCirAllowCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of DCE allowed rate Configuration information."
::= { hwFrClassObjects 3 }
hwCirAllowCfgInfoEntry OBJECT-TYPE
SYNTAX HwCirAllowCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DCE allowed ratee Configuration Information Entry."
INDEX { hwCirAllowFrClassIndex,
hwCirAllowDirection}
::= { hwCirAllowCfgInfoTable 1 }
HwCirAllowCfgInfoEntry ::=
SEQUENCE {
hwCirAllowFrClassIndex
Integer32,
hwCirAllowDirection
Integer32,
hwCirAllowValue
Integer32,
hwCirAllowRowStatus
RowStatus
}
hwCirAllowFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
::= { hwCirAllowCfgInfoEntry 1 }
hwCirAllowDirection OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet Direction.
value 1,2,3 Used by hwCirAllowValue.
inbound (1)
outbound (2)
inbound and outbound (3)
"
::= { hwCirAllowCfgInfoEntry 2 }
hwCirAllowValue OBJECT-TYPE
SYNTAX Integer32(1..45000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DCE allowed rate (value greater than CIR)
Unit : Bits per second.
Value : <1-45000000> ."
::= { hwCirAllowCfgInfoEntry 3 }
hwCirAllowRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwCirAllowCfgInfoEntry 4 }
-- Cir on the Fr Class
hwCirCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCirCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Committed Information Rate Configuration information."
::= { hwFrClassObjects 4 }
hwCirCfgInfoEntry OBJECT-TYPE
SYNTAX HwCirCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Committed Information Rate Configuration Information Entry."
INDEX { hwCirFrClassIndex }
::= { hwCirCfgInfoTable 1 }
HwCirCfgInfoEntry ::=
SEQUENCE {
hwCirFrClassIndex
Integer32,
hwCirValue
Integer32,
hwCirRowStatus
RowStatus
}
hwCirFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
::= { hwCirCfgInfoEntry 1 }
hwCirValue OBJECT-TYPE
SYNTAX Integer32(1000..45000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" CIR in packet output direction ,bps.
Value : <1000-45000000>."
::= { hwCirCfgInfoEntry 2 }
hwCirRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwCirCfgInfoEntry 3 }
-- Fr Class Instance on interface Table
hwIfApplyFrClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwIfApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of QoS Fr Class instance."
::= { hwFrClassObjects 5 }
hwIfApplyFrClassEntry OBJECT-TYPE
SYNTAX HwIfApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FrClass applied on interface Configuration Information Entry."
INDEX { hwIfApplyFrClassIfIndex }
::= { hwIfApplyFrClassTable 1 }
HwIfApplyFrClassEntry ::=
SEQUENCE {
hwIfApplyFrClassIfIndex
Integer32,
hwIfApplyFrClassIndex
Integer32,
hwIfApplyFrClassRowStatus
RowStatus
}
hwIfApplyFrClassIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface Index, equal to ifIndex."
::= { hwIfApplyFrClassEntry 1 }
hwIfApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Fr Class, equal to hwFrClassIndex"
::= { hwIfApplyFrClassEntry 2 }
hwIfApplyFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwIfApplyFrClassEntry 3 }
-- Fr Class Instance on fr pvc Table
hwPvcApplyFrClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwPvcApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of QoS Fr Class instance."
::= { hwFrClassObjects 6 }
hwPvcApplyFrClassEntry OBJECT-TYPE
SYNTAX HwPvcApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Class applied on FR Pvc Configuration Information Entry."
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwPvcApplyFrClassTable 1 }
HwPvcApplyFrClassEntry ::=
SEQUENCE {
hwPvcApplyFrClassIfIndex
Integer32,
hwPvcApplyFrClassDlciNum
Integer32,
hwPvcApplyFrClassIndex
Integer32,
hwPvcApplyFrClassRowStatus
RowStatus
}
hwPvcApplyFrClassIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fr Interface Index, equal to ifIndex."
::= { hwPvcApplyFrClassEntry 1 }
hwPvcApplyFrClassDlciNum OBJECT-TYPE
SYNTAX Integer32 (16..1007)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fr DLCI number."
::= { hwPvcApplyFrClassEntry 2 }
hwPvcApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Fr Class, equal to hwFrClassIndex"
::= { hwPvcApplyFrClassEntry 3 }
hwPvcApplyFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwPvcApplyFrClassEntry 4 }
-- bandwidth parameter on interface
hwFrPvcBandwidthTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwFrPvcBandwidthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Running statistics for bandwidth.
"
::= { hwFrClassObjects 7 }
hwFrPvcBandwidthEntry OBJECT-TYPE
SYNTAX HwFrPvcBandwidthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bandwidth Running statistics"
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwFrPvcBandwidthTable 1 }
HwFrPvcBandwidthEntry ::=
SEQUENCE {
hwFrPvcBandwidthMaxReservedBW
Integer32,
hwFrPvcBandwidthAvailable
Integer32
}
hwFrPvcBandwidthMaxReservedBW OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max reserved bandWidth. Unit : Kbps"
::= { hwFrPvcBandwidthEntry 1 }
hwFrPvcBandwidthAvailable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Available bandWidth. Unit : Kbps"
::= { hwFrPvcBandwidthEntry 2 }
-- hwRTPQoSObjects
hwRTPQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 2 }
-- Rtpq applied on the Fr Class
hwRTPFrClassApplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwRTPFrClassApplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of QoS rtpq instance."
::= { hwRTPQoSObjects 1 }
hwRTPFrClassApplyEntry OBJECT-TYPE
SYNTAX HwRTPFrClassApplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Rtpq Configuration Information Entry."
INDEX { hwRTPFrClassApplyFrClassIndex }
::= { hwRTPFrClassApplyTable 1 }
HwRTPFrClassApplyEntry ::=
SEQUENCE {
hwRTPFrClassApplyFrClassIndex
Integer32,
hwRTPFrClassApplyStartPort
Integer32,
hwRTPFrClassApplyEndPort
Integer32,
hwRTPFrClassApplyBandWidth
Integer32,
hwRTPFrClassApplyCbs
Integer32,
hwRTPFrClassApplyRowStatus
RowStatus
}
hwRTPFrClassApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fr Class Index, equal to HwFrClassIndex."
::= { hwRTPFrClassApplyEntry 1 }
hwRTPFrClassApplyStartPort OBJECT-TYPE
SYNTAX Integer32(2000..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
RTP-PORT(3): start-port: 2000~65535
"
::= { hwRTPFrClassApplyEntry 2 }
hwRTPFrClassApplyEndPort OBJECT-TYPE
SYNTAX Integer32(2000..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
RTP-PORT(3): end-port: 2000~65535
"
::= { hwRTPFrClassApplyEntry 3 }
hwRTPFrClassApplyBandWidth OBJECT-TYPE
SYNTAX Integer32 (8..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Max bandWidth Value:
Absolute value: 8~1000000. Unit: Kbps
"
::= { hwRTPFrClassApplyEntry 4 }
hwRTPFrClassApplyCbs OBJECT-TYPE
SYNTAX Integer32 (1500..2000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Committed Burst Size: 1500~2000000. Unit: byte
"
::= { hwRTPFrClassApplyEntry 5 }
hwRTPFrClassApplyRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus for RTPFrClassApply Table.
Three actions are used: active, createAndGo, destroy"
::= { hwRTPFrClassApplyEntry 6 }
-- RTPQ statistics on the Fr Pvc
hwRTPFrPvcQueueRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwRTPFrPvcQueueRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Running statistics for RTPQ Queue
applied on the FR PVC"
::= { hwRTPQoSObjects 2 }
hwRTPFrPvcQueueRunInfoEntry OBJECT-TYPE
SYNTAX HwRTPFrPvcQueueRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Queue statistics entry."
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwRTPFrPvcQueueRunInfoTable 1 }
HwRTPFrPvcQueueRunInfoEntry ::=
SEQUENCE {
hwRTPFrPvcQueueSize
Integer32,
hwRTPFrPvcQueueMaxSize
Integer32,
hwRTPFrPvcQueueOutputs
Counter32,
hwRTPFrPvcQueueDiscards
Counter32
}
hwRTPFrPvcQueueSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of Rtpq Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 1 }
hwRTPFrPvcQueueMaxSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max size of Rtpq Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 2 }
hwRTPFrPvcQueueOutputs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outputs of Rtpq Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 3 }
hwRTPFrPvcQueueDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discards of Rtpq Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 4 }
END
--