mibs/MIBS/huawei/HUAWEI-ND-MIB

308 lines
12 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- =================================================================
-- Copyright (C) 2017 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: Huawei Ethernet ND MIB
-- Reference: HUAWEI Enterprise MIB
-- Version: V1.03
-- History:
-- gaoning , 2014-06-27, add nodes for ND.
-- =================================================================
HUAWEI-ND-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Counter32, Integer32, Unsigned32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
PhysAddress, DisplayString, RowStatus
FROM SNMPv2-TC
NOTIFICATION-GROUP, OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
ifIndex, ifName, InterfaceIndex,InterfaceIndexOrZero,ifAdminStatus,ifOperStatus,ifDescr
FROM IF-MIB
PhysicalIndex, entPhysicalIndex, entPhysicalName
FROM ENTITY-MIB;
hwNDMIB MODULE-IDENTITY
LAST-UPDATED "201708171600Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"Please provide the descritpion."
REVISION "201708171600Z"
DESCRIPTION "V1.02, Modify description of hwNDSlotThresholdExceedValue and hwNDIntfThresholdExceedValue at 2017-07-04"
REVISION "201707041600Z"
DESCRIPTION "V1.02, Modify description of hwSlotNDThresholdExceedAlarm at 2017-07-04."
REVISION "201407011600Z"
DESCRIPTION "V1.01, initial version."
REVISION "201008111600Z"
DESCRIPTION "V1.00, initial version."
::= { hwDatacomm 332 }
hwNDObjects OBJECT IDENTIFIER ::= { hwNDMIB 1 }
-- =================================================================
-- 1th slot nd entries alarm
-- =================================================================
hwNDStatisticsPerSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwNDStatisticsPerSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the threshold of the alarm generated in slot."
::= { hwNDObjects 1 }
hwNDStatisticsPerSlotEntry OBJECT-TYPE
SYNTAX HwNDStatisticsPerSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the threshold of the alarm generated in slot."
INDEX {hwNDSlotPhysicalIndex}
::= { hwNDStatisticsPerSlotTable 1 }
HwNDStatisticsPerSlotEntry ::=
SEQUENCE {
hwNDSlotPhysicalIndex Unsigned32 ,
hwNDSlotThresholdExceedValue Unsigned32 ,
hwNDSlotThresholdResumeValue Unsigned32 ,
hwNDSlotDynamicNumber Unsigned32 ,
hwNDSlotStaticNumber Unsigned32 ,
hwNDSlotTotalNumber Unsigned32
}
hwNDSlotPhysicalIndex OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot of alarm generated."
::= { hwNDStatisticsPerSlotEntry 1 }
hwNDSlotThresholdExceedValue OBJECT-TYPE
SYNTAX Unsigned32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is greater than or equal to the alarm threshold."
::= { hwNDStatisticsPerSlotEntry 2 }
hwNDSlotThresholdResumeValue OBJECT-TYPE
SYNTAX Unsigned32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold."
::= { hwNDStatisticsPerSlotEntry 3 }
hwNDSlotDynamicNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current dynamic ND entries in slot."
::= { hwNDStatisticsPerSlotEntry 4 }
hwNDSlotStaticNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current static ND entries in slot."
::= { hwNDStatisticsPerSlotEntry 5 }
hwNDSlotTotalNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum ND entries number for slot."
::= { hwNDStatisticsPerSlotEntry 6 }
-- =================================================================
-- 2th interface nd entries alarm
-- =================================================================
hwNDStatisticsPerIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwNDStatisticsPerIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the threshold of the alarm generated in interface."
::= { hwNDObjects 2 }
hwNDStatisticsPerIfEntry OBJECT-TYPE
SYNTAX HwNDStatisticsPerIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the threshold of the alarm generated in interface."
INDEX {hwNDIntfIndex}
::= { hwNDStatisticsPerIfTable 1 }
HwNDStatisticsPerIfEntry ::=
SEQUENCE {
hwNDIntfIndex Unsigned32 ,
hwNDIntfThresholdExceedValue Unsigned32 ,
hwNDIntfThresholdResumeValue Unsigned32 ,
hwNDIntfDynamicNumber Unsigned32 ,
hwNDIntfStaticNumber Unsigned32 ,
hwNDIntfTotalNumber Unsigned32
}
hwNDIntfIndex OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface of alarm generated."
::= { hwNDStatisticsPerIfEntry 1 }
hwNDIntfThresholdExceedValue OBJECT-TYPE
SYNTAX Unsigned32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an ND entry alarm threshold on an interface. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is greater than or equal to the alarm threshold."
::= { hwNDStatisticsPerIfEntry 2 }
hwNDIntfThresholdResumeValue OBJECT-TYPE
SYNTAX Unsigned32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an ND entry clear alarm threshold on an interface. An ND entry clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is less than or equal to the clear alarm threshold."
::= { hwNDStatisticsPerIfEntry 3 }
hwNDIntfDynamicNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current dynamic ND entries in interface."
::= { hwNDStatisticsPerIfEntry 4 }
hwNDIntfStaticNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current static ND entries in interface."
::= { hwNDStatisticsPerIfEntry 5 }
hwNDIntfTotalNumber OBJECT-TYPE
SYNTAX Unsigned32(0..4294967294)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum ND entries number for interface."
::= { hwNDStatisticsPerIfEntry 6 }
-- Notifications(trap) Definitions
hwNDNotifications OBJECT IDENTIFIER ::= { hwNDMIB 2 }
hwSlotNDThresholdExceedAlarm NOTIFICATION-TYPE
OBJECTS { entPhysicalName, hwNDSlotThresholdExceedValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber }
STATUS current
DESCRIPTION
"This object indicates that an alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is greater than or equal to the 80% threshold."
::= { hwNDNotifications 1 }
hwSlotNDThresholdResumeAlarm NOTIFICATION-TYPE
OBJECTS { entPhysicalName,hwNDSlotThresholdResumeValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber }
STATUS current
DESCRIPTION
"This object indicates that a clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is less than or equal to the 70% threshold."
::= { hwNDNotifications 2 }
hwInterfaceNDThresholdExceedAlarm NOTIFICATION-TYPE
OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdExceedValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber }
STATUS current
DESCRIPTION
"This object indicates that an alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is greater than or equal to the 80% threshold."
::= { hwNDNotifications 3 }
hwInterfaceNDThresholdResumeAlarm NOTIFICATION-TYPE
OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdResumeValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber }
STATUS current
DESCRIPTION
"This object indicates that a clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is less than or equal to the 70% threshold."
::= { hwNDNotifications 4 }
-- Conformance information
hwNDConformance OBJECT IDENTIFIER ::= { hwNDMIB 3 }
hwNDGroups OBJECT IDENTIFIER ::= { hwNDConformance 1 }
hwNDCompliances OBJECT IDENTIFIER ::= { hwNDConformance 2 }
hwNDSlotGroup OBJECT-GROUP
OBJECTS {
hwNDSlotPhysicalIndex,
hwNDSlotThresholdExceedValue,
hwNDSlotThresholdResumeValue,
hwNDSlotDynamicNumber,
hwNDSlotStaticNumber,
hwNDSlotTotalNumber
}
STATUS current
DESCRIPTION
"A collection of objects for ND threshold alarm in interface."
::= { hwNDGroups 1 }
hwNDIntfGroup OBJECT-GROUP
OBJECTS {
hwNDIntfIndex,
hwNDIntfThresholdExceedValue,
hwNDIntfThresholdResumeValue,
hwNDIntfDynamicNumber,
hwNDIntfStaticNumber,
hwNDIntfTotalNumber
}
STATUS current
DESCRIPTION
"A collection of objects for ND threshold alarm in slot."
::= { hwNDGroups 2 }
hwNDNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS{ hwSlotNDThresholdExceedAlarm, hwSlotNDThresholdResumeAlarm, hwInterfaceNDThresholdExceedAlarm, hwInterfaceNDThresholdResumeAlarm}
STATUS current
DESCRIPTION
"notification Group."
::= { hwNDGroups 3 }
hwNDCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for ND thre."
MODULE
MANDATORY-GROUPS {
hwNDSlotGroup,
hwNDIntfGroup
}
::= { hwNDCompliances 1 }
-- =================================================================
-- units of conformance
-- =================================================================
END