2023-12-05 12:25:34 +01:00
-- =================================================================
-- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description: This mib file is used for management of huawei userlog
-- information.
-- Reference:
-- Version: V1.1
-- History:
-- tianli,2003.3.31,publish
-- Zhang Peng,2004.5.19,Reunification version based on V1.0 .
-- =================================================================
HUAWEI-USERLOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
IpAddress, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
hwDatacomm
FROM HUAWEI-MIB;
-- 1.3.6.1.4.1.2011.5.25.18
hwUserLogMIB MODULE-IDENTITY
LAST-UPDATED "200304100000Z"
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
" R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:support@huawei.com "
DESCRIPTION
"The HUAWEI-USERLOG-MIB contains objects to
manage configuration and monitor running state
for userlog feature.
For users who access network through NAT and BAS
equipments, their IP addresses are generally
unfixed, and so it is hard to exactly locate which
host a certain access comes from and which user
initiates it. This decreases the network security.
User log is designed to solve the problem. User log
can record Network Address Translation (NAT) flow
information, and login/ logout information and flow
information of Broadband Access Server (BAS) user,
thus enabling the administrator know address
information before NAT, access record of BAS user, etc.
Then, network activities and operations can be queried
and tracked, and network availability and security are
improved accordingly."
::= { hwDatacomm 18 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.2011.5.25.18.1
hwUserlogObjects OBJECT IDENTIFIER ::= { hwUserLogMIB 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1
hwUserlogNatObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.1
hwUserlogNatVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NAT LOG version. Currently only version 1 is developed."
::= { hwUserlogNatObjects 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.2
hwUserlogNatSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NAT LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format and is recommended.
Syslog can be used in the case that log amount is not too large."
::= { hwUserlogNatObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.3
hwUserlogNatSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of NAT LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet."
::= { hwUserlogNatObjects 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.4
hwUserlogNatFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Log the NAT flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor is required.
The default value 0 means this function is disabled."
::= { hwUserlogNatObjects 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.5
hwUserlogNatActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The active time for long-time existed NAT flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, NAT flow can be logged after an interval of active time.
This function will be used when real-time monitor is required.
The default value 0 means real-time monitor function is disabled. "
::= { hwUserlogNatObjects 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6
hwUserlogNatSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG configuration information for the specified slot.
By default, user log function is disabled on the interface board.
Only after user log function is enabled, the other configurations
related to user log take effect."
::= { hwUserlogNatObjects 6 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1
hwUserlogNatSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG configuration information entry for a slot."
INDEX { hwUserlogNatCfgSlotNumber }
::= { hwUserlogNatSlotCfgInfoTable 1 }
HwUserlogNatSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogNatCfgSlotNumber
Integer32,
hwUserlogNatEnable
Integer32,
hwUserlogNatAclNumber
Integer32,
hwUserlogNatHostAddress
IpAddress,
hwUserlogNatUdpPort
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.1
hwUserlogNatCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The object specifies which slot is configured with NAT LOG.
For NAT LOG, it is the slot of the egress interface
configured with NAT."
::= { hwUserlogNatSlotCfgInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.2
hwUserlogNatEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The NAT LOG feature status.
If 1, NAT LOG is enabled.
If 0, NAT LOG is disabled.
The default value 0 means NAT LOG is disabled."
::= { hwUserlogNatSlotCfgInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.3
hwUserlogNatAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access-list number. Its range is 2000 ~ 3999.
The value 0 means no ACL is specified.
Only when NAT LOG is enabled, and ACL is configured.
Only NAT flow which match the ACL will be logged. "
::= { hwUserlogNatSlotCfgInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.4
hwUserlogNatHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of NAT LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally."
::= { hwUserlogNatSlotCfgInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.5
hwUserlogNatUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of NAT LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024."
::= { hwUserlogNatSlotCfgInfoEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7
hwUserlogNatSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG running information for the specified slot."
::= { hwUserlogNatObjects 7 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1
hwUserlogNatSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG running information entry for a slot."
INDEX { hwUserlogNatRunSlotNumber }
::= { hwUserlogNatSlotRunInfoTable 1 }
HwUserlogNatSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogNatRunSlotNumber
Integer32,
hwUserlogNatTotalEntries
Counter32,
hwUserlogNatTotalPackets
Counter32,
hwUserlogNatFailedEntries
Counter32,
hwUserlogNatFailedPackets
Counter32,
hwUserlogNatClearRunStat
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.1
hwUserlogNatRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The object specifies on which slot the NAT LOG statistics are calculated."
::= { hwUserlogNatSlotRunInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.2
hwUserlogNatTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries which are logged."
::= { hwUserlogNatSlotRunInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.3
hwUserlogNatTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets generated by the device."
::= { hwUserlogNatSlotRunInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.4
hwUserlogNatFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries failed in outputting."
::= { hwUserlogNatSlotRunInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.5
hwUserlogNatFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets failed in outputting."
::= { hwUserlogNatSlotRunInfoEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.6
hwUserlogNatClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clears the running statistics for NAT LOG. Its access is write-only.
If 1, the running statistics for NAT LOG is resetted.
Other value is invalid."
::= { hwUserlogNatSlotRunInfoEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2
hwUserlogFlowObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.1
hwUserlogFlowVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS FLOW LOG version. Currently only version 1 is developed."
::= { hwUserlogFlowObjects 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.2
hwUserlogFlowSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BAS FLOW LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
Syslog can be used in the case that log amount is not
too large."
::= { hwUserlogFlowObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.3
hwUserlogFlowSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS FLOW LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet."
::= { hwUserlogFlowObjects 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.4
hwUserlogFlowFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Log the BAS flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor is required.
The default value 0 means this function is disabled."
::= { hwUserlogFlowObjects 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.5
hwUserlogFlowActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The active time for long-time existed BAS flow.
Its unit is minute. Its range is 10 minutes ~ 120 minutes.
When setting it, BAS flow can be logged after an internal of active time.
This function will be used when real-time monitor is required.
The default value 0 means real-time monitor function
is disabled. "
::= { hwUserlogFlowObjects 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6
hwUserlogFlowSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG configuration information for the specified slot.
By default, user log function is disabled on the interface board.
Only after user log function is enabled, the other configurations
related to user log take effect."
::= { hwUserlogFlowObjects 6 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1
hwUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS FLOW LOG configuration information entry for a slot."
INDEX { hwUserlogFlowCfgSlotNumber }
::= { hwUserlogFlowSlotCfgInfoTable 1 }
HwUserlogFlowSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogFlowCfgSlotNumber
Integer32,
hwUserlogFlowEnable
Integer32,
hwUserlogFlowAclNumber
Integer32,
hwUserlogFlowHostAddress
IpAddress,
hwUserlogFlowUdpPort
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.1
hwUserlogFlowCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The ojects specifies which slot is configured with BAS FLOW LOG. "
::= { hwUserlogFlowSlotCfgInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.2
hwUserlogFlowEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BAS FLOW LOG feature status.
If 1, BAS FLOW LOG is enabled.
If 0, BAS FLOW LOG is disabled.
The default value 0 means BAS FLOW LOG is disabled."
::= { hwUserlogFlowSlotCfgInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.3
hwUserlogFlowAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access-list number. Its range is 2000 ~ 3999.
The value 0 means no ACL is specified.
Only when BAS FLOW LOG is enabled, the ACL be configured.
Only BAS flow which match the ACL will be logged. "
::= { hwUserlogFlowSlotCfgInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.4
hwUserlogFlowHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS FLOW LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally."
::= { hwUserlogFlowSlotCfgInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.5
hwUserlogFlowUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS FLOW LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024."
::= { hwUserlogFlowSlotCfgInfoEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7
hwUserlogFlowSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG running information for the specified slot."
::= { hwUserlogFlowObjects 7 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1
hwUserlogFlowSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hwUserlogFlowRunSlotNumber }
::= { hwUserlogFlowSlotRunInfoTable 1 }
HwUserlogFlowSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogFlowRunSlotNumber
Integer32,
hwUserlogFlowTotalEntries
Counter32,
hwUserlogFlowTotalPackets
Counter32,
hwUserlogFlowFailedEntries
Counter32,
hwUserlogFlowFailedPackets
Counter32,
hwUserlogFlowClearRunStat
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.1
hwUserlogFlowRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The object specifies on which slot the BAS FLOW LOG statistics are calculated."
::= { hwUserlogFlowSlotRunInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.2
hwUserlogFlowTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW Entries which are logged. "
::= { hwUserlogFlowSlotRunInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.3
hwUserlogFlowTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of FLOW LOG UDP packet generated by the device. "
::= { hwUserlogFlowSlotRunInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.4
hwUserlogFlowFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW entries failed in outputting. "
::= { hwUserlogFlowSlotRunInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.5
hwUserlogFlowFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW LOG UDP packet failed in outputting."
::= { hwUserlogFlowSlotRunInfoEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.6
hwUserlogFlowClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clears the running statistics for FLOW LOG. Its access is write-only.
If 1, the running statistics for FLOW LOG is resetted.
Other value is invalid."
::= { hwUserlogFlowSlotRunInfoEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3
hwUserlogAccessObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.1
hwUserlogAccessVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS ACCESS LOG version. Currently only version 1 is developed."
::= { hwUserlogAccessObjects 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.2
hwUserlogAccessSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BAS ACCESS LOG format.
If 1, LOG format is sysLog;
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
Syslog can be used in the case that log amount is not too large."
::= { hwUserlogAccessObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.3
hwUserlogAccessSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS ACCESS LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet."
::= { hwUserlogAccessObjects 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4
hwUserlogAccessSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG configuration information for the specified slot."
::= { hwUserlogAccessObjects 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1
hwUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HwUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS ACCESS LOG configuration information entry for a slot."
INDEX { hwUserlogAccessCfgSlotNumber }
::= { hwUserlogAccessSlotCfgInfoTable 1 }
HwUserlogAccessSlotCfgInfoEntry ::=
SEQUENCE {
hwUserlogAccessCfgSlotNumber
Integer32,
hwUserlogAccessEnable
Integer32,
hwUserlogAccessHostAddress
IpAddress,
hwUserlogAccessUdpPort
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.1
hwUserlogAccessCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The object specifies which slot is configured with BAS ACCESS LOG. "
::= { hwUserlogAccessSlotCfgInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.2
hwUserlogAccessEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BAS ACCESS LOG feature status.
If 1, BAS ACCESS LOG is enabled.
If 0, BAS ACCESS LOG is disabled.
The default value 0 means BAS ACCESS LOG is disabled."
::= { hwUserlogAccessSlotCfgInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.3
hwUserlogAccessHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS ACCESS LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally."
::= { hwUserlogAccessSlotCfgInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.4
hwUserlogAccessUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS ACCESS LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024."
::= { hwUserlogAccessSlotCfgInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5
hwUserlogAccessSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG running information
for the specified slot."
::= { hwUserlogAccessObjects 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1
hwUserlogAccessSlotRunInfoEntry OBJECT-TYPE
SYNTAX HwUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hwUserlogAccessRunSlotNumber }
::= { hwUserlogAccessSlotRunInfoTable 1 }
HwUserlogAccessSlotRunInfoEntry ::=
SEQUENCE {
hwUserlogAccessRunSlotNumber
Integer32,
hwUserlogAccessTotalEntries
Counter32,
hwUserlogAccessTotalPackets
Counter32,
hwUserlogAccessFailedEntries
Counter32,
hwUserlogAccessFailedPackets
Counter32,
hwUserlogAccessClearRunStat
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.1
hwUserlogAccessRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number.
The object specifies on which slot the BAS ACCESS LOG statistics
are calculated."
::= { hwUserlogAccessSlotRunInfoEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.2
hwUserlogAccessTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS records which are logged. "
::= { hwUserlogAccessSlotRunInfoEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.3
hwUserlogAccessTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ACCESS LOG UDP packet generated by the router."
::= { hwUserlogAccessSlotRunInfoEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.4
hwUserlogAccessFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS entries failed in outputting."
::= { hwUserlogAccessSlotRunInfoEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.5
hwUserlogAccessFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS LOG UDP packet failed in outputting."
::= { hwUserlogAccessSlotRunInfoEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.6
hwUserlogAccessClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the running statistics for ACCESS LOG. Its access is write-only.
If 1, the running statistics for ACCESS LOG is resetted,
the other value is invalid."
::= { hwUserlogAccessSlotRunInfoEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.18.2
hwUserlogNotifications OBJECT IDENTIFIER ::= { hwUserLogMIB 2 }
-- 1.3.6.1.4.1.2011.5.25.18.3
hwUserlogConformance OBJECT IDENTIFIER ::= { hwUserLogMIB 3 }
-- 1.3.6.1.4.1.2011.5.25.18.3.1
hwUserlogCompliances OBJECT IDENTIFIER ::= { hwUserlogConformance 1 }
-- 1.3.6.1.4.1.2011.5.25.18.3.1.1
hwUserlogCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement the Huawei Userlog mib."
MODULE -- this module
MANDATORY-GROUPS { hwUserlogMandatoryGroup }
::= { hwUserlogCompliances 1 }
-- 1.3.6.1.4.1.2011.5.25.18.3.2
hwUserlogGroups OBJECT IDENTIFIER ::= { hwUserlogConformance 2 }
-- 1.3.6.1.4.1.2011.5.25.18.3.2.1
hwUserlogMandatoryGroup OBJECT-GROUP
OBJECTS { hwUserlogNatEnable, hwUserlogNatHostAddress, hwUserlogNatUdpPort, hwUserlogFlowEnable, hwUserlogFlowHostAddress,
hwUserlogFlowUdpPort, hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort }
STATUS current
DESCRIPTION
"A collection of objects providing mandatory Userlog information."
::= { hwUserlogGroups 1 }
-- 1.3.6.1.4.1.2011.5.25.18.3.2.2
hwUserlogConfigGroup OBJECT-GROUP
OBJECTS { hwUserlogNatVersion, hwUserlogNatSyslog, hwUserlogNatSourceIP, hwUserlogNatFlowBegin, hwUserlogNatActiveTime,
hwUserlogNatCfgSlotNumber, hwUserlogNatEnable, hwUserlogNatAclNumber, hwUserlogNatHostAddress, hwUserlogNatUdpPort,
hwUserlogFlowVersion, hwUserlogFlowSyslog, hwUserlogFlowSourceIP, hwUserlogFlowFlowBegin, hwUserlogFlowActiveTime,
hwUserlogFlowCfgSlotNumber, hwUserlogFlowEnable, hwUserlogFlowAclNumber, hwUserlogFlowHostAddress, hwUserlogFlowUdpPort,
hwUserlogAccessVersion, hwUserlogAccessSyslog, hwUserlogAccessSourceIP, hwUserlogAccessCfgSlotNumber, hwUserlogAccessEnable,
hwUserlogAccessHostAddress, hwUserlogAccessUdpPort }
STATUS current
DESCRIPTION
"All configurable parameters of Userlog feature."
::= { hwUserlogGroups 2 }
-- 1.3.6.1.4.1.2011.5.25.18.3.2.3
hwUserlogInfoGroup OBJECT-GROUP
OBJECTS { hwUserlogNatTotalEntries, hwUserlogNatTotalPackets, hwUserlogNatFailedEntries, hwUserlogNatFailedPackets, hwUserlogFlowTotalEntries,
hwUserlogFlowTotalPackets, hwUserlogFlowFailedEntries, hwUserlogFlowFailedPackets, hwUserlogAccessTotalEntries, hwUserlogAccessTotalPackets,
hwUserlogAccessFailedEntries, hwUserlogAccessFailedPackets }
STATUS current
DESCRIPTION
"All running information of Userlog feature."
::= { hwUserlogGroups 3 }