mibs/MIBS/huawei/HWMUSA-DEV-MIB

887 lines
22 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ============================================================================
-- Copyright (C)2011 by HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: The MIB module defines MIB objects which provide
-- device management NMS interfaces.
-- Reference:
-- Version: V1.18
-- ============================================================================
HWMUSA-DEV-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwFrameIndex, hwSlotIndex
FROM HUAWEI-DEVICE-MIB
hwProducts
FROM HUAWEI-MIB
HWPCBType,HWFrameType
FROM HUAWEI-TC-MIB
Integer32, OBJECT-TYPE,Unsigned32,MODULE-IDENTITY
FROM SNMPv2-SMI
RowStatus, DateAndTime
FROM SNMPv2-TC;
musa MODULE-IDENTITY
LAST-UPDATED "201201180000Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"
The MIB module defines MIB objects which provide device management NMS interfaces.
"
-- Revision history
REVISION "201203310000Z"
DESCRIPTION "V1.18, Added enumerated value 0x02000173 to hwMusaBoardLatestResetCause's value list."
REVISION "201201170000Z"
DESCRIPTION "V1.17, Added hwMusaFramePowerSupplyTable node."
REVISION "201111180000Z"
DESCRIPTION "V1.16, Added enumerated value dcAndRemote(8) and acAndDc(9) to hwMusaFramePowerMode's value list."
REVISION "201107080000Z"
DESCRIPTION "V1.15, Time and type of last Board reset on OLT devices."
REVISION "201101120000Z"
DESCRIPTION "V1.14, Added enumerated value acRemote(7) to hwMusaFramePowerMode's value list.."
REVISION "201011100000Z"
DESCRIPTION "V1.13, Modified the description of hwMusaSlotConfExtTable, hwMusaSlotConfExtEntry, hwMusaBoardTemperature,
hwMusaSlotAverageConfTable, hwMusaSlotAverageConfEntry, hwMusaBoardStatisticTime, hwXPONBoardParaTable, hwXPONBoardParaEntry,
hwBroadBandFrameOperTable, hwBroadBandFrameOperEntry and hwIasConfigChangeEntry."
REVISION "201008190000Z"
DESCRIPTION "V1.12, Modified the description of the objects in this MIB file for MIB standardization."
REVISION "201003240000Z"
DESCRIPTION "V1.11, Modified this MIB for clearing simple tester errors and warnings."
REVISION "201002220000Z"
DESCRIPTION "V1.10, Added enumerated value pd(6) to hwMusaFramePowerMode's value list."
REVISION "201002100000Z"
DESCRIPTION "V1.09, Modified MIB descriptions."
REVISION "201002030000Z"
DESCRIPTION "V1.08, Cleared compile warnings."
REVISION "200907220000Z"
DESCRIPTION "V1.07, Added enumerated value linePowered(5) to hwMusaFramePowerMode's value list."
REVISION "200907200000Z"
DESCRIPTION "V1.06, Added hwMusaFramePower, hwMusaBoardPower, and hwMusaBoardActivedPortNum."
REVISION "200611270000Z"
DESCRIPTION "V1.00, Initial version."
::= { hwProducts 6 }
ias OBJECT IDENTIFIER ::= { musa 7 }
hwIasDev OBJECT IDENTIFIER ::= { ias 1 }
hwMusaSlotConf OBJECT IDENTIFIER ::= { hwIasDev 1 }
hwMusaFrameExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwMusaFrameExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Frame description extended table.The table describes the bandwidth of the frame,
and also contains the EMU and slot information of the frame.
The index of this table is hwFrameIndex. It is the frame ID.
"
::= { hwMusaSlotConf 1 }
hwMusaFrameExtEntry OBJECT-TYPE
SYNTAX HwMusaFrameExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Frame description extended table.The table describes the bandwidth of the frame,
and also contains the EMU and slot information of the frame.
The index of this entry is hwFrameIndex. It is the frame ID.
"
INDEX { hwFrameIndex }
::= { hwMusaFrameExtTable 1 }
HwMusaFrameExtEntry ::=
SEQUENCE {
hwMusaFrameLimtBandWidth
Integer32,
hwMusaFrameDistBandWidth
Integer32,
hwMusaFrameTestGroupID
Integer32,
hwMusaFrameEmuId1
Integer32,
hwMusaFrameEmuId2
Integer32,
hwMusaFrameEmuId3
Integer32,
hwMusaFrameEmuId4
Integer32,
hwMusaFrameEmuId5
Integer32,
hwMusaFrameSlotConnection
OCTET STRING,
hwMusaFramePowerMode
INTEGER,
hwMusaFramePower
Integer32
}
hwMusaFrameLimtBandWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Frame limit bandwidth,the maximum bandwidth of the frame.
Unit: K. It is used in debug mode. 1G = 1000M.
"
::= { hwMusaFrameExtEntry 1 }
hwMusaFrameDistBandWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Frame distributed bandwidth.
Unit: K. It is used in debug mode. 1G = 1000M.
"
::= { hwMusaFrameExtEntry 2 }
hwMusaFrameTestGroupID OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 3 }
hwMusaFrameEmuId1 OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 4 }
hwMusaFrameEmuId2 OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 5 }
hwMusaFrameEmuId3 OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 6 }
hwMusaFrameEmuId4 OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 7 }
hwMusaFrameEmuId5 OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 8 }
hwMusaFrameSlotConnection OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaFrameExtEntry 9 }
hwMusaFramePowerMode OBJECT-TYPE
SYNTAX INTEGER
{
localac(1),
localdc(2),
localacBackuppower(3),
backuppower(4),
remotedc(5),
pd(6),
remoteac(7),
localdcAndRemotedc(8),
localacAndlocaldc(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Frame power supply mode.
Options:
1.localac(1) -local 220V AC power supply
2.localdc(2) -local DC power supply
3.localacBackuppower(3) -AC power and backuppower supply
4.backuppower(4) -accumulator supply
5.remotedc(5) -remote line +/-190V high voltage power supply of DC
6.pd(6) -powered device supply
7.remoteac(7) -remote 60V AC power supply
8.localdcAndRemotedc(8) -DC power and Remote power are provided at the same time
9.localacAndlocaldc(9) -DC power and AC power are provided at the same time
"
::= { hwMusaFrameExtEntry 10 }
hwMusaFramePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The total power of the frame.
It includes the power of service boards, active control board, standby control board,
interface boards, and environment monitoring boards.
Unit: watt.
"
::= { hwMusaFrameExtEntry 11 }
hwMusaSlotConfExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwMusaSlotConfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Board description extended table.
The tabel is used for describing the extended information
about all boards in each slot of the shelf.
The indexes of this table are hwFrameIndex and hwSlotIndex.
"
::= { hwMusaSlotConf 2 }
hwMusaSlotConfExtEntry OBJECT-TYPE
SYNTAX HwMusaSlotConfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Board description extended table.
The tabel is used for describing the extended information
about all boards in each slot of the shelf.
The indexes of this entry are hwFrameIndex and hwSlotIndex.
"
INDEX { hwFrameIndex, hwSlotIndex }
::= { hwMusaSlotConfExtTable 1 }
HwMusaSlotConfExtEntry ::=
SEQUENCE {
hwMusaBoardLimitBandWidthUp
Integer32,
hwMusaBoardLimitBandWidthDown
Integer32,
hwMusaBoardHasBandWidthUp
Integer32,
hwMusaBoardHasBandWidthDown
Integer32,
hwMusaBoardCpuRate
Integer32,
hwMusaBoardRamUseRate
Integer32,
hwMusaBoardSlotDesc
OCTET STRING,
hwMusaBoardOnlineState
INTEGER,
hwMusaServiceChannelBufferRate
Integer32,
hwMusaBoardTemperature
Integer32,
hwMusaBoardPower
Integer32,
hwMusaBoardActivedPortNum
Integer32,
hwMusaBoardLatestResetTime
DateAndTime,
hwMusaBoardLatestResetCause
Integer32
}
hwMusaBoardLimitBandWidthUp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaSlotConfExtEntry 1 }
hwMusaBoardLimitBandWidthDown OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaSlotConfExtEntry 2 }
hwMusaBoardHasBandWidthUp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaSlotConfExtEntry 3 }
hwMusaBoardHasBandWidthDown OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaSlotConfExtEntry 4 }
hwMusaBoardCpuRate OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Active and standby control board CPU usage.
It does not support RSP, PV8, BAS, or other boards.
-1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal.
"
::= { hwMusaSlotConfExtEntry 5 }
hwMusaBoardRamUseRate OBJECT-TYPE
SYNTAX Integer32 ( -1 | 0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Active and standby control board RAM usage.
It does not support RSP, PV8, BAS, AIC, or other boards.
-1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal.
"
::= { hwMusaSlotConfExtEntry 6 }
hwMusaBoardSlotDesc OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Slot information description.
It describes the name of the slot.
"
::= { hwMusaSlotConfExtEntry 7 }
hwMusaBoardOnlineState OBJECT-TYPE
SYNTAX INTEGER
{
online(1),
offline(2),
unmanageable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Board online state.
Options:
1.online(1) -board is online
2.offline(2) -board is offline
3.unmanageable(3) -board is faulty
"
::= { hwMusaSlotConfExtEntry 8 }
hwMusaServiceChannelBufferRate OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Service channel buffer usage.
It only supports the xDSL service board on the MA5600 and the MA5600T product.
-1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal.
"
::= { hwMusaSlotConfExtEntry 9 }
hwMusaBoardTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Board temperature.The value 0X7FFFFFF indicates invalid temperature.
It only supports the H801SCUB and H801SCUL boards.
"
::= { hwMusaSlotConfExtEntry 10 }
hwMusaBoardPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The power of the board.
Unit: watt.
"
::= { hwMusaSlotConfExtEntry 11 }
hwMusaBoardActivedPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The number of activated ports on one board.
"
::= { hwMusaSlotConfExtEntry 12 }
hwMusaBoardLatestResetTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The latest reset time of the board.
"
::= { hwMusaSlotConfExtEntry 13 }
hwMusaBoardLatestResetCause OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The latest reset cause of the board.
0x00000000 - There is no reset record of the board.
0x02000000 - The communication with the control board is abnormal.
0x02000165 - COM user delivers board reset command.
0x02000167 - NMS user delivers board reset command.
0x02000169 - Telnet user delivers board reset command.
0x0200016b - User add board manually.
0x020000a1 - The board temperature is too high, which causes the shutdown of the board.
0x02000173 - The board resets because the working mode is changed.
0x02000181 - The service board is automatically shut down when it is not configured with any service.
0x02000182 - The service board is automatically shut down when the mains supply is interrupted.
0x020001b5 - The board is loosened or is removed forcibly.
0x0700000a - The active/standby switchover command is manually delivered.
"
::= { hwMusaSlotConfExtEntry 14 }
hwMusaSlotAverageConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwMusaSlotAverageConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this table are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
::= { hwMusaSlotConf 3 }
hwMusaSlotAverageConfEntry OBJECT-TYPE
SYNTAX HwMusaSlotAverageConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this entry are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
INDEX { hwFrameIndex, hwSlotIndex, hwMusaBoardStatisticTime }
::= { hwMusaSlotAverageConfTable 1 }
HwMusaSlotAverageConfEntry ::=
SEQUENCE {
hwMusaBoardStatisticTime
INTEGER,
hwMusaBoardCpuAverageRate
Integer32
}
hwMusaBoardStatisticTime OBJECT-TYPE
SYNTAX INTEGER
{
five-seconds(1),
one-minute(2),
ten-minutes(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
Options:
1. five-seconds(1) -five seconds
2. one-minute(2) -one minute
3. ten-minutes(3) -ten minutes
"
::= { hwMusaSlotAverageConfEntry 1 }
hwMusaBoardCpuAverageRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwMusaSlotAverageConfEntry 2 }
hwXPONBoardParaTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwXPONBoardParaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this table are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
::= { hwMusaSlotConf 4 }
hwXPONBoardParaEntry OBJECT-TYPE
SYNTAX HwXPONBoardParaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this entry are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
INDEX { hwXPONBoardParaFrameIndex, hwXPONBoardParaSlotIndex }
::= { hwXPONBoardParaTable 1 }
HwXPONBoardParaEntry ::=
SEQUENCE {
hwXPONBoardParaFrameIndex
Integer32,
hwXPONBoardParaSlotIndex
Integer32,
hwXPONBoardSN
OCTET STRING,
hwXPONBoardPassWord
OCTET STRING,
hwXPONBoardMacAddr
OCTET STRING
}
hwXPONBoardParaFrameIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwXPONBoardParaEntry 1 }
hwXPONBoardParaSlotIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwXPONBoardParaEntry 2 }
hwXPONBoardSN OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..96))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwXPONBoardParaEntry 3 }
hwXPONBoardPassWord OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..96))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwXPONBoardParaEntry 4 }
hwXPONBoardMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(17..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwXPONBoardParaEntry 5 }
hwBroadBandFrameOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBroadBandFrameOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this table are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
::= { hwIasDev 2 }
hwBroadBandFrameOperEntry OBJECT-TYPE
SYNTAX HwBroadBandFrameOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
The indexes of this entry are hwFrameIndex and hwSlotIndex.
This table is not supported.
"
INDEX { hwFrameIfIndex }
::= { hwBroadBandFrameOperTable 1 }
HwBroadBandFrameOperEntry ::=
SEQUENCE {
hwFrameIfIndex
Integer32,
hwBroadBandFrameType
HWFrameType,
hwMainBoardSlots
Integer32,
hwMainBoardType
HWPCBType,
hwBroadBandFrameID
Integer32,
hwBroadBandFrameRowStatus
RowStatus
}
hwFrameIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 1 }
hwBroadBandFrameType OBJECT-TYPE
SYNTAX HWFrameType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 2 }
hwMainBoardSlots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 3 }
hwMainBoardType OBJECT-TYPE
SYNTAX HWPCBType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 4 }
hwBroadBandFrameID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 5 }
hwBroadBandFrameRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This node is not supported.
"
::= { hwBroadBandFrameOperEntry 6 }
hwIasConfigChange OBJECT IDENTIFIER ::= { ias 5 }
hwIasConfigChangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwIasConfigChangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Configuration change type trap table.
The index of this table is hwIasConfigChangeTrapID. It is the trap ID.
"
::= { hwIasConfigChange 1 }
hwIasConfigChangeEntry OBJECT-TYPE
SYNTAX HwIasConfigChangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Configuration change type trap table.
The index of this entry is hwIasConfigChangeTrapID. It is the trap ID.
"
INDEX { hwIasConfigChangeTrapID }
::= { hwIasConfigChangeTable 1 }
HwIasConfigChangeEntry ::=
SEQUENCE {
hwIasConfigChangeTrapID
Integer32,
hwIasConfigChangeSerialSN
Integer32
}
hwIasConfigChangeTrapID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Configuration change type trap ID.
"
::= { hwIasConfigChangeEntry 1 }
hwIasConfigChangeSerialSN OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Configuration change type trap serial number.
"
::= { hwIasConfigChangeEntry 2 }
hwMusaFramePowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwMusaFramePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The power supply query table.
The table is used to get supply state of all the power supply input.
The index of this table is hwFrameIndex,hwMusaPowerSupplyInputMode and hwMusaPowerSupplyID.
"
::= { hwMusaSlotConf 5 }
hwMusaFramePowerSupplyEntry OBJECT-TYPE
SYNTAX HwMusaFramePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The power supply query table.
The table is used to get supply state of all the power supply input.
The index of this entry is hwFrameIndex,hwMusaPowerSupplyInputMode and hwMusaPowerSupplyID.
"
INDEX { hwFrameIndex, hwMusaPowerSupplyInputMode, hwMusaPowerSupplyID }
::= { hwMusaFramePowerSupplyTable 1 }
HwMusaFramePowerSupplyEntry ::=
SEQUENCE {
hwMusaPowerSupplyInputMode
INTEGER,
hwMusaPowerSupplyID
Integer32,
hwMusaPowerSupplyState
INTEGER
}
hwMusaPowerSupplyInputMode OBJECT-TYPE
SYNTAX INTEGER
{
localac(1),
localdc(2),
remoteac(3),
remotedc(4),
pd(5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power supply input mode.
Options:
1. localac(1) -local 220V AC power supply
2. localdc(2) -local DC power supply
3. remoteac(3) -remote 60V AC power supply
4. remotedc(4) -remote line +/-190V high voltage power supply of DC
5. pd(5) -powered device supply
"
::= { hwMusaFramePowerSupplyEntry 1 }
hwMusaPowerSupplyID OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The input index of power supply."
::= { hwMusaFramePowerSupplyEntry 2 }
hwMusaPowerSupplyState OBJECT-TYPE
SYNTAX INTEGER
{
valid(1),
invalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of power supply.
Options:
1. valid(1) -this power input is working
2. invalid(2) -this power input is not working
"
::= { hwMusaFramePowerSupplyEntry 3 }
END